About this file

This is a pre-solicitation notice for a multiple award task order contract for construction services. The Department of Veterans Affairs Veterans Integrated Services Network 23 intends to issue a request for proposal to make multiple indefinite-delivery, indefinite-quantity contract awards for maintenance, repair, alteration, and new construction projects ranging from $2,000 to $10 million. The construction MATOC will cover facilities in the Minneapolis and St. Cloud VA health care systems and their associated clinics in Minnesota. A minimum of eight awards are anticipated under North American Industry Classification System code 236220 for commercial and institutional building construction, with a $36.5 million small business size standard. This acquisition is set aside solely for service-disabled veteran-owned small businesses. Offerors must represent their status as such and be registered in the required systems. Interested parties should monitor the federal business opportunities website for solicitation details.

36C26318R0688 0001 ATTACHMENT 11j--Record Drawings 656-16-277 Relocate Rehab Functions (11 pages).pdf

View the file

Other files

File Type Posted
36C26319D0094-000.docx DOCX document
36C26319D0093-000.docx DOCX document
36C26319D0092-000.docx DOCX document
36C26319D0091-000.docx DOCX document
36C26319D0090-000.docx DOCX document
36C26319D0089-002.docx DOCX document
36C26319D0088-001.docx DOCX document
36C26318R0688-0003000.docx DOCX document
36C26318R0688-0002002.pdf PDF
36C26318R0688-0002000.docx DOCX document
36C26318R0688-0002003.pdf PDF
36C26318R0688-0002001.pdf PDF
36C26318R0688-0001000.docx DOCX document
36C26318R0688-0001003.pdf PDF
36C26318R0688-0001005.pdf PDF
36C26318R0688-0001004.pdf PDF
36C26318R0688-0001001.pdf PDF
36C26318R0688-0001006.pdf PDF
36C26318R0688-0001007.pdf PDF
36C26318R0688-072.docx DOCX document
36C26318R0688-090.pdf PDF
36C26318R0688-088.pdf PDF
36C26318R0688-071.docx DOCX document
36C26318R0688-078.pdf PDF
36C26318R0688-077.pdf PDF
36C26318R0688-076.pdf PDF
36C26318R0688-075.pdf PDF
36C26318R0688-064.docx DOCX document
36C26318R0688-066.docx DOCX document
36C26318R0688-069.docx DOCX document
36C26318R0688-086.pdf PDF
36C26318R0688-087.pdf PDF
36C26318R0688-082.pdf PDF
36C26318R0688-084.pdf PDF
36C26318R0688-068.docx DOCX document
36C26318R0688-067.docx DOCX document
36C26318R0688-081.pdf PDF
36C26318R0688-079.pdf PDF
36C26318R0688-070.docx DOCX document
36C26318R0688-083.pdf PDF
36C26318R0688-085.pdf PDF
36C26318R0688-073.xls XLS spreadsheet
36C26318R0688-074.pdf PDF
36C26318R0688-065.docx DOCX document
36C26318R0688-089.pdf PDF
36C26318R0688-080.pdf PDF
36C26318R0688.docx DOCX document
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FB1

SP

SB

FP

FW1

LD

The first digit refers to the level on which the room occurs in a multi-level building. In a one-level building, this digit may be omitted.

The second digit refers to the area of that particular level where the room occurs when the campus is divided into different areas or buildings. If only one area or building exist, this digit may be omitted.

The last two or three digits identify the room.

Vis: 2R17 or 2R174

Rooms are numbered in the following manner:

ROOM AND DOOR NUMBERS

Grid lines are traces of imaginary vertical planes, identified by number and/or letter, used to facilitate the location of materials. Where no dimensions are shown and the materials are shown to occur with some definite relationship to the grid lines, then these materials shall be installed in this relationship.

GRID LINES

4C

Indicates demolition note described elsewhere on documents

Indicates note described elsewhere on documents

Indicates door number; see door schedule.

Indicates wall type. The wall type number is described in the wall type legend found on all floor plan sheets a/1 Indicates revision's to issued documents

Indicates equipment item; see equipment schedule202

1A101

W1 Indicates window number; see window types XXX.XX

XXX.XX

Note, Description

(XXX.XX)

Drapery

Cubicle Curtain Track

(Existing Spot Elevation)

Corner Guard

Elevation of Building Component(s) Relative to the Base Elevation

New Spot Elevation

Accordian Door

ARCHITECTURAL SYMBOLS

Existing Walls to Remain (shown shaded)

Walls to be Removed (shown dotted)

WALL GRAPHICS

New Walls (shown solid)

TAGS

CW1 Indicates curtain wall frame number; see curtain wall frame types

S1 Indicates storefront frame number; see storefront frame types

SYMBOLS

A501

Indicates building exterior elevation detail number sheet number

A401 Indicates building interior elevation detail number sheet number

FIRE BARRIER (1 HR, 2HR RATED

x INDICATES HOUR RATING)

SMOKE PARTITION

SMOKE BARRIER

WALL RATING LINES

x

FIRE PARTITION (1 HR RATED)

FIRE WALL (1 HR, 2HR RATED x

INDICATES HOUR RATING)

x

LEAD LINED WALL

L1 Indicates louver frame number; see louver types

F1 Indicates interior window number; see window types

A601

Indicates detail referenced Indicates building & wall section cut location

...and shall be referred to in correspondence as elevation 12/ 6-2.

Indicates detail number on that sheet Indicates number of sheet where section, elevation, or detail appears

Vis:

Where double numbers appear in a circle on scale drawings or elevations, the upper number is the number of the section or elevation on the sheet so numbered... the lower number indicates the sheet on which a section or elevation of the part in question may be found;

DETAIL AND SECTION REFERENCING

EXPLANATION OF DOCUMENT NOMENCLATURE

Information shown on plans will not be repeated on elevations and sections and vice versa. Where notes are indefinite, reference must be made to the specifications. When practical, notes upon the plans are eliminated, and information is condensed in the form of schedules which appear in the Project Manual.

Combinations of abbreviations consistent with the following abbreviations list may occur. When any feature of the building occurs more than once, it is drawn in full only once, and repetitions of the same feature are indicated in outline; it is the intention that all of such features indicated in outline shall be complete in every detail as shown in the typical instance. Features which are shown in detail at a larger scale will be indicated in outline only on the smaller scale drawings. Where plans or elevations are symmetrical, one-half will be drawn in full, and the other indicated in outline only;

and when any feature is continuous, a portion only will be shown in full and the remainder in outline.

In order to avoid an unnecessary amount of lettering and a confusing number of lines on the Contract Documents, the Architect/Engineer has used certain devices, abbreviations, conventions, symbols, diagrams and schedules, the meaning and use of which are herein illustrated and explained.

The Contract Documents cannot be fully and correctly interpreted without reference to these explanatory sheets and to the specifications contained in the Project Manual.

A701

A701

Indicates detail section cut location

A701 view direction view direction view direction

A701

Indicates a plan details and enlarged plans

A

@ At A Amp A Compressed Air A/C Air Conditioning ACC Accessory/Accessories ACT Acoustical Ceiling Tile ADA Americans with Disabilities Act ADD Addendum ADJ Adjustable ADO Automatic Door Operator AF Access Flooring AFF Above Finish Floor AFG Above Finish Grade AHU Air Handling Unit AIC Ampere Interrupting Capacity ALT Alternate ALUM Aluminum ANN Annunciator ARCH Architectural ASI Architect’s Supplemental Instructions AT Acoustical Ceiling Tile AT(SP) Acoustical Ceiling (with Sprayed Plastic Finish) ATS Automatic Transfer Switch A/V Audio Visual AWC Acoustical Wall Covering

B

B Blinds - Horizontal BATH Bathroom BCS Baby Changing Station BD Board BEJ Brick Expansion Joint BFE Bottom of Footing Elevation BITUM Bituminous BKSPL Backsplash BLDG Building BLK Block BLKG Blocking BM Beam BM Benchmark BOT Bottom BR Bedroom BRG Bearing BSMT Basement BSP Bedspread BTU British Thermal Units BV Blinds - Vertical

C

C Conduit C Concrete C/L Center Line CA Carpet CAB Cabinet CAM Camera CATV Cable Television CB Catch Basin CB Circuit Breaker CBB Concrete Backer Board CCT Circuit CFM Cubic Feet per Minute CFT Ceramic Floor Tile CG Corner Guard CJ Control Joint CJ CMU Control Joint CLG Ceiling CLR Clear CM Cultured Marble CM Crown Molding CO Cleanout CO Company COL Column CONC Concrete CONF Conference CONT Continuous CORR Corridor CP Cultured Polymer CPT Carpet Tile CR Chair Rail CSR Central Sterile Room CT Ceramic Tile CT Current Transformer CT Computer Aided Tomography CTP Countertop CU Clean Utility CUH Cabinet Unit Heater CWT Ceramic Wall Tile

D

D Drapery DBL Double DC Direct Current DET Detail DF Drinking Fountain DIA Diameter DIFF Diffuser DIM Dimension DISC Disconnect DIST Distance DISTR Distributor DR Dust Room DR Door DRP Door Protection DRWG Drawing DS Down Spout DT Dust Tight

E

E East E Existing EA Each EC Electrical Contractor EIFS Exterior Insulation & Finish System EJ Expansion Joint ELEC Electrical ELEV Elevator ELEV Elevation EMT Electric Metallic Tubing EOL End of Line EP Electrical Panel EPF Epoxy Flooring EQ Equal EQUIP Equipment ER Emergency ES Engineered Interior Surface ES Each Side EWC Electrical Water Cooler EXIST Existing EXP Expansion EXT Exterior

F

F Fahrenheit F Flush FAAP Fire Alarm Annunciator Panel FACP Fire Alarm Control Panel FB Face Brick FBO Furnished By Others FCIC Furnished by Contractor Installed by Contractor FCU Fan Coil Unit FD Floor Drain FDMPR Fire Damper FDN Foundation FDR Feeder FE Fire Extinguisher FFE Finished Floor Elevation FGP Fiberglass Panel FIN FLR Finished Floor FLA Full Load Amps FLUORO Fluoroscopy or Fluoroscopic FMA Flexible Metal Conduit FOIC Furnished by Owner Installed by Contractor FOIO Furnished by Owner Installed by Owner FP Fireproof or Fireproofing FP Folding Partition FR Fire Retardant FRS Flushing Rim Sink FS Firestopping FS Floor Sink FS Flow Switch FS Finish Sheet FURN Furniture FV Field Verify

G

G Ground GA Gauge GB Gypsum Board GC General Contractor GEN General GFCI Ground Fault Circuit Interrupter GND Ground GPH Gallons Per Hour GPM Gallons Per Minute GRB Grab Bar GWB Gypsum Wallboard Systems GYP BD Gypsum Board

H

HD Heavy Duty HDB Hardboard HDWE Hardware HK Hook HM Hollow Metal HP Horsepower HR Handrail HS Hand Sanitizer HSKP Housekeeping HT Height HTR Heater HUMD Humidifier HV High Voltage HVAC Heating Ventilating Air Conditioning HW Hot Water HW HR Hot Water Heating Return HW HS Hot Water Heating Supply HWH Hot Water Heater HWR Hot Water Return HWS Hot Water Supply HZ Hertz

I

ICB Integrally Coved Base ICU Intensive Care Unit IE Invert Elevation IG Isolated Ground IMC Intermediate Metal Conduit INFO Information INSUL Insulation INT Interior INV Invert

J

JAN Janitor JB Junction Box JT Joint

K

KIT Kitchen KO Knock Out KCMIL Thousand Circular Miles KP Kickplate KV Kilovolts KVA Kilovolt Amperes KW Kilowatt KWH Kilowatt Hour L

L Lintel LAV Lavatory LDR Labor/Delivery/Recovery LDRP Labor/Delivery/Recovery/Post-Partum LN Linoleum LNDRY Laundry LS Light Switch LT Light LTG Lighting LV Low Voltage

M

M Mat (Floor) MAMMO Mammography MAS Masonry MATL Material MAX Maximum MB Marker Board MCB Main Circuit Branch MCC Motor Control Center MFR Manufacturer MH Manhole MIN Minimum MIR Mirror MISC Miscellaneous MLDG Molding MLO Main Lug Only MO Masonry Opening MOD Modular MOT Motor MSB Main Switch Board MTG Mounting MTS Manual Transfer Switch MTL Metal

N

N North NC Normally Closed NEC National Electric Code NIC Not In Contract NL Night Light NO Normally Open NOM Nominal NS Nurse Station NTS Not To Scale

O

O/C On Center O.C. On Center OB Obstetrics OD Outside Diameter OD Overflow Drain OR Operating Room OT Occupational Therapy OUT Outlet OUTPAT Outpatient

P

P Pole P Paint P/C Precast Concrete PAR Post-Anesthesia Recovery PAT RM Patient Room PB Pull Box PB Push Button PERP Perpendicular PF Power Factor PH Phase PHARM Pharmacy PLYWD Plywood PR Pair PR Proposal Request PRB Profile Base PRI Primary PREFIN Prefinished PRV Power Roof Ventilator PRV Pressure Reducing Valve PSI Pounds per Square Inch PT Paint PT Physical Therapy PTD Paper Towel Dispenser PWR Power PV Porcelain Paver PVC Polyvinyl Chloride

Q

QT Quarry Tile QTY Quantity

R

R Resistance R Radius R Rubber RA Return Air RB Resilient Base RAD Radiology REC Recessed RCP Reflected Ceiling Plan RD Roof Drain RECP Receptacle RECPN Reception REF Refrigerator RF Resilient Floor RF Rubber Flooring RFS Room Finish Schedule RJ Roof Jack RL Relocate RM Room RPM Revolutions Per Minute RPS Revolutions Per Second RPZ Reduced Pressure Zone Backflow Device RS Rubber Stair Tread RSF Resilient Sheet Flooring RT Rain Tight RT Rubber Tile RWL Rain Water Leader

S

S South S Solid Surface SAF Safety Floor SC High Build Glazed Coating (Special Coating) SCHED Schedule SD Soap Dispenser SEAL CONC Sealed Concrete SEC Secondary SHR Shower SP Solid Polymer SP Spare SPEC Specifications SQ Square SQ FT Square Foot SQ IN Square Inch SS Stainless Steel ST Stain STL Steel SU Soiled Utility SURG Surgery SUSP Suspended SW Switch SWBD Switchboard SYM Symmetrical

T

T Toilet T Thermostat TBD Tackboard TBE Top of Beam Elevation TC Telecommunications Cabinet TDE Top of Deck Elevation TER Terrazzo TERM Terminal TFE Top of Footing Elevation TP Tamper Resistant TPH Toilet Paper Holder TREAT Treatment TSE Top of Slab Elevation TWE Top of Wall Elevation TYP Typical

U

U Urinal UC Under Counter or Under Cabinet UG Underground UH Unit Heater UL Underwriters’ Laboratory UN Unless Noted UNO Unless Noted Otherwise UV Unit Ventilator

V

V Vinyl V Volt VA Volt-Amperes VAC Vacuum VB Vertical Blind VCT Vinyl Composite Tile VCW Vinyl Clad Wood VOL Volume VT Vapor Tight

W

W West W/O Without WAGD Waste Anesthetic Gas Disposal WC Water Closet WC Wallcovering WCH Wheelchair WD Wood WDW Window WF or W Wide Flange Steel Beam WG Wall Guard WP Wall Protection WR Water Resistant WS Weatherstripping WS Working Scupper WSCT Wainscot WSF Welded Seam Sheet Flooring WT Watertight WT Weight WTR Water WWF Welded Wire Fabric

X

XFMR Transformer XP Explosion Proof

Z

Z Impedance

ABBREVIATIONS

FB1

SP

SB

FP

FW1

LD

FW2

SP

FB1

FB2

FB1

FB1

STEEL

1. 7/8"

2. 1 5/8"

3. 2 1/2"

4. 3 5/8"

6. 6"

8. 8"

WOOD

2. 2X2 (1 1/2")

4. 2X4 (3 1/2")

6. 2X6 (5 1/2")

8. 2X8 (7 1/4")

10. 2X10 (9 1/4")

ONE LAYER 5/8" GYP BD

TWO LAYERS 5/8" GYP BD

STUD THICKNESS

ONE LAYER 5/8" GYP BD

AIR SPACE

3 5/8" STEEL STUD

3 5/8" STEEL STUD

ONE LAYER 5/8" GYP BD

ONE LAYER 5/8" GYP BD

S E

E P

LA

N

1 HR - UL U465 - STEEL

1 HR - UL U305 - WOOD

2 HR - UL U411 - STEEL

2 HR - UL U301 - WOOD

WALL RATING INDICATOR, SEE PLAN

WALL RATING INDICATOR, SEE PLAN

WALL RATING INDICATOR, SEE PLAN

A STL

C STL

B WD

D WD

E STL

F WD

J

4C

STUD SIZE AND

STANDARD WALL

ASSEMBLY

J SPECIAL WALL ASSEMBLY

WALL ASSEMBLY

K

S E

E P

LA

N

2 HR - UL U336 - FIRE SEPERATION

AIR SPACE

2X4 WOOD STUD

2X4 WOOD STUD

ONE LAYER 5/8" GYP BD

ONE LAYER 5/8" GYP BD

WALL RATING INDICATOR, SEE PLAN

TWO LAYERS 1" GYP BD

1 HR - UL U420 - PLUMBING WALL

FURRING OR STUD

NOTE: ALL INTERIOR WALLS TO BE TYPE

"4C" UNLESS NOTED OTHERWISE.

SOUND ATTENUATING INSULATION

1 HR - UL U465 - STEEL

1 HR - UL U305 - WOOD

WALL RATING INDICATOR, SEE PLAN

ONE LAYER 5/8" GYP BD

TWO LAYERS 5/8" GYP BD

SOUND ATTENUATING INSULATION

METAL STUD GUSSET AT THIRD POINTS,

EACH STUD

SOUND ATTENUATING INSULATION

TWO LAYERS 5/8" GYP BD

SOUND ATTENUATING INSULATION

ONE LAYER 5/8" GYP BD

G STL

H WD

FIRE BARRIER (1 HR, 2HR RATED

x INDICATES HOUR RATING)

SMOKE PARTITION

SMOKE BARRIER

WALL RATING LEGEND

SMOKE BARRIER PARTITIONS TO BE

CONTINUOUS FROM FLOOR TO

STRUCTURE ABOVE. REFER TO PLANS

FOR LOCATIONS AND EXTENTS.

PASSAGE OF PIPES, CONDUITS, DUCTS,

CABLES AND SIMILAR EQUIPMENT

SHALL BE SEALED WITH A MATERIAL

CAPABLE OF MAINTAINING FIRE AND

SMOKE RESISTANCE - REFER TO SEC

07240 x

FIRE PARTITION (1 HR RATED)

FIRE WALL (1 HR, 2HR RATED x

INDICATES HOUR RATING)

x

LEAD LINED WALL

ONE LAYER 5/8" GYP BD

1 HR - UL U465 - STEEL

WALL RATING INDICATOR, SEE PLAN

L

ONE LAYER 1" GYPSUM SHAFT WALL LINER

C-H METAL STUD3

1/ 8"

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Sara Malin License No. 40063

COPYRIGHT This drawing is the copyrighted work product of Architect and reuse, modification or reproduction of these documents without express written consent of Architect is prohibited. The architectural or related services performed or furnished by the Architect for this project are provided subject to the care and skill ordinarily exercised by members of the architectural profession practicing under similar circumstances at the same time and in the same locality. Architect makes no warranties, express or implied, in connection with its services.

C

No DATEREVISION

DRAWING TITLE

APPROVED: CHIEF OF STAFF

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: CHIEF OF POLICE

APPROVED: DIRECTOR FMS DATE: APPROVED: SAFETY MANAGER DATE:

APPROVED: GEMS COORDINATOR

APPROVED: PROJECTS SECTION MANAGER

APPROVED: SERVICE LINE DIRECTOR

DATE:

DATE:

DATE: APPROVED: INFECTION CONTROL NURSE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE:

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DATE:

DATE: DRAWING NO.

DRAWN

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE

REHABILITATION CENTER

PROJECT #656-332

St. Cloud VA Health Care System

SYMBOLS &

ABBREVIATIONS &

WALL TYPES

11/13/2018

S1430

A001

1 9/30/16 RECORD SET

DN

DN

34" 34" 34" 34"

DN

REF.

32"32"

32" 32" 36"36"

24"24" 48"

30" 24" 24"

30"

32" 32"

30"

FDFD

FD

FD

FD

48"

FD

DN

48"

SBSB

SB

SB

SBSB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SP

SP

SPSP SP SP

FB1FB1 FB1 FB1 FB1 FB1 FB1 FB1 FB1 FB1

FB

FB

FB

FB

FB1

FB

FB

FB

FB1FB1FB1FB1FB1FB1FB1FB1FB1FB1

FB1FB1 FB1 FB1 FB1 FB1 FB1

FB

FB

FB

1FB

FB

FB

FB

FB1

FB1FB1 FB1

FB

FB

FB

FB1FB1FB1

FB

FB

FB

FB1FB1 FB1

FB

FB

FB

FB

FB

FB1FB1 FB1

FB

FB

FB

FB

FB

FB

FB1FB1FB1

FB

FB1FB1FB1FB1FB1

FB

FB

FB

FB

FB

FB1FB1 FB1

FB1FB1 FB1 FB1 FB1

FB

FB

SP

SPSP

SP

SP

SPSP SP SP SP SP

SPSP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP SP

SPSP

SP

SP

SP

SP

SP

SPSP SP SP

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

SPSP

SP

SP

SPSP SP SP SP

SPSP

SP

SP

SP

SP

SBSB SB

SBSB SB

SBSB

SB

SB

SBSB

SB

SB

SBSB

SB

SB

SPSP SP SP

SP

SPSPSP

A5012

A501

A501

A501

FUTURE LINK

1:33

DASHED LINE INDICATES

DROP-OFF CANOPY ABOVE

SNOW MELT SYSTEM - BOTH

SIDES

(ALTERNATE #14 ELIMINATE)

SNOW MELT SYSTEM

(ALTERNATE #14 ELIMINATE)

SIDE FOLDING

SECURITY GRILLE

'-4

27'-2" 19'-8" 47'-4" 19'-8" 27'-2"

103°

'-4

/2

1' -9

/4

4'

-4

4' -0

9'

-4

4'-2" 4'-0" 2'-8" 4'-0" 2'-8" 4'-0" 5'-8" 3'-4" 4'-0" 5'-0" 4'-0" 3'-4" 4'-0" 4'-0" 2'-8" 4'-0" 18'-0" 4'-0" 2'-8" 4'-0" 4'-0" 3'-4" 4'-0" 5'-0" 4'-0" 3'-4" 5'-0" 4'-0" 2'-8" 4'-0" 2'-8" 4'-0" 4'-10"3'-4" 35'-4" 3'-4" 10'-0" 3'-4" 10'-0" 3'-4" 12'-0"

3'-4" 6'-8"

3'-4" 6'-8"

3'-4" 6'-8"

3'-4"

19' - 5" +/-

E Q

. A

'-0

E Q

. A

1/

2" 6'

-4

1/

2"

AHU-1

RAMP DOWN

TO BUILDING 51

4'

-4

141'-0"

E-22

DF

A301 5D

FFE 97'-7"

EXISTING BLDG 51

A301 1F

A301

2B

2C

A301

3A

A301

3B

A301

2D

2E

A601

A601

DF

CUBICLE CURTAIN

TRACK ABOVE

(TYP.)

WC STOR.

A601

A602

5'-0" 35'-9" 10'-0"

AD101

MAX

R

AM

P 40'-0"

97' - 7"

98' - 11"

101A

101B

142B

142C

108 107

104B

142D

104A

137A

176A 174A

105 142A 160

176B

171170169

175A

A402

SOUTH

VESTIBULE

STAFF

OP GYM

T-4

FEMALE

TOILET ROOM

SCHEDULING

WORK

RECEPTION

PT GYM

PT CHARTING

EQUIP

STORAGE

T-1

T-5

PATIENT

TOILET

T-3

T-6

MECHANICAL

MUSIC

NORTH

VESTIBULE

PROS

STORAGE

CORRIDOR

WAITING

JAN

GROUP

MEETING

ROOM

SOCIAL

WORKER

CONSULTATION

PASS

THROUGH

LINK TO

BUILDING 51

ASSESSMENT/

CONSULTATION

MALE TOILET

MALE TOILET

ROOM

T-2

CORRIDOR

ELECTRICAL

WAITING

FEMALE

TOILET

T-7

100' - 0"

TV - FOIOTV - FOIO

FEC

E-25

PIANO

PIANO

CART

A301

1B

E-22

A301

1A

E-18 E-27

A301

5C

E-15

E-17

E-19

E-20

E-33

E-34

E-28

E-28

CEILING LIFT

E-32

E-35 E-37

E-21

E-29 E-30 E-31

E-14

E-16

05 E-23

E-26

E-24

FEC

A301

1C

FEC

126A

135 134

123B

126B

110A

114A

123A

110B

175B

A301 1D

A301

1E

A301 2A

CLEAN LINEN

SOILED LINEN

ELECTRICAL

LOW

VOLTAGE

114B

142E

RECYCLING

TALL STOR CABINETS

ELEC.

PANELS

SEE

ELEC.

DN

UP

IT

2F

CLEAN

UTILITY

A602

1:33

ALTERNATE #9

LINK TO

BUILDING 51

ALTERNATE #12 ELIMINATE

BUILDING CANOPY

HALLWAY

CLEAR

8' - 1"

6C

TRANSFORMER PAD

DOOR

OPENER ON

BOLLARD

DOOR OPENER

ON BOLLARD

SIDEWALK- TYP.

STOOP- SEE

STRUCT.

AREA WELL

4A

4A

2A 4A

2A

4A

STOOP- SEE

STRUCT.

STOOP- SEE STRUCT.

STOOP- SEE

STRUCT.

10' - 8"

110C

A102 3A

TRASH

ENCLOSURE

8' -0

1B

A702

AREA WELL

7' -3

" V

IF

3/

4" T

Y P

9 3/4" TYP.

3' -8

7'

-8

3' -8

/4

4'

-0

2' -8

4'

-0

9' -0

/4

4'

-0

2' -8

4'

-0

2' -1

1/

2"

2' -6

6'

-4

2' -8

6'

-4

2' -8

6'

-4

2' -6

7'

-4

4' -0

2'

-8

4' -0

'-6

'-8

7'

-6

BEJ

BEJ BEJ

BEJ BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJBEJ

BEJ

BEJBEJ

BEJ

BEJ

BEJ

BEJBEJ

BEJBEJ

EJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ BEJ

BEJ

BEJ BEJ

BEJ

BEJ

EJ

BEJ BEJ BEJBEJBEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ

BEJ BEJ BEJ

BEJ BEJBEJ BEJ

A702 4C10'-8"

3' - 4" 3' - 4"11' - 5"

A702 3C

INDUSTRIAL

OPEN-RISER

STAIR

(STAIR S-4)

STAIR

S1

STAIR

S2

TYP.

TYP.

E-36

A402

A402

1G

TYP.

BCS

BCS

BCS

BCS

1'-0"

EJ

EJ

C

LE

A R

8' -1

4'-11" 4'-0" 2'-8" 4'-0" 2'-8" 4'-0" 4'-11" 2'-4" 3'-4" 4'-10" 3'-4" 5'-10" 5'-10" 4'-6" 4'-0" 4'-4" 10'-0" 4'-4" 4'-0" 4'-6" 5'-10" 5'-8" 3'-4" 5'-0" 3'-4" 2'-4" 5'-0" 4'-0" 2'-8" 4'-0" 2'-8" 4'-0" 4'-10"

3' -8

4'

-0

2' -0

4'

-0

5' -4

4'

-0

2' -0

4'

-0

4' -8

4'

-0

2' -0

4'

-0

3' -0

2'

-6

6' -4

2'

-8

6' -4

2'

-8

6' -4

2'

-6

'-4

8'

-4

9' -5

/4

14'-5"

'-5

/4

'-4

/4

8' -5

'-1 1"

'-6

9'-2" 10'-8 3/4" 22'-3 1/2"

CLEAR

8'-1"

10'-1 3/4"

15'-7 1/4" 15'-11 1/2"

20'-3 1/2" 18'-4 1/2" 9'-7" 11'-10 1/4" 11'-10 1/2" 10'-0 1/4"

6' - 8" 4' - 10" 10' - 1" 7' - 0"

2' - 2"

4' - 10"

5'-8 1/2" 9'-11 1/4" 1'-4" 9'-11" 3' -7

/2

C

LE

A R

8' -1

3'

-8

2' -7

/2

'-1

/4

1' -2

7'

-2

/4

C

LE

A R

8' -1

8'

-1

J

8'-3 1/4"

CLEAR

8'-1" 20'-3 1/2"

4'-0"

13'-9 1/2"

8'-7" 4'-8 1/4" 8'-11"

'-7

/4

4'

-3

/2

5' -1

3/

4"

C

LE

A R

8' -1

/4

'-2

/4

8' -5

9'

-5

9' -6

/4

'-9

/2

9'

-8

1' -9

'-2

8'

-4

/4

2' -5

/4

'-6

/4

'-1

0"

J

J

2' -2

/2

1'-0"

5' -0

8' -8

/4

6' -1

1" 2'

-0

6' -1

1"

'-1

1/ 2"

'-2

10'-8 1/2" 18'-2 1/2"

A603 1C

A603 1D

J

4A

4A

ENTRANCE

GRILL

ENTRANCE GRILL

ENTRANCE

GRILL

A702 4B

6A4A

4A

6A

4A

TYP. @ LINK

4A TYP. @

LINK

6C

FEC

SYSTEMS

FURNITURE

BY DIV. 12

MAINTENANCE

PAD - SEE MECH.

6' -7

1'

-1

2A

4A

4A

4A

4A

4A

4A

4A

4A4A4A4A4A

4A

4A4A

4A

4A4A

4A

4A

4A

4A 1'-2 1/4"

3/

4"

4A 4A

4A

F1

CONTINIOUS

MAINTENANCE

STRIP

CONTINIOUS

MAINTENANCE

STRIP

8' -1

1"

2A

4A

4A

4A

2A

4A

4A2A

4A

2A

4A

2A

2A2A

4A 2A

2A

2A

2A

2A

4A

4A

1A

4A

4A

4A

4A

A601

F2

F2

C

LE

A R

2' -0

SF2 SF2

FE

FAAP

8' -0

2'

-0

8' -0

E

QE

Q

2' -5

137B

SF7

1A1A

OWNER TO PROVIDE SIGNAGE

STATING THAT NO STORAGE IS

PERMITTED IN CRAWL SPACE

DOOR OPENER

ON BOLLARD

3/4" TOPPING DEPRESSION

3/4" TOPPING

DEPRESSION

3/4" TOPPING

DEPRESSION

FLOOR HATCH BY

DIV. 08 31 13 -

90 MIN. RATING

100' - 0" 100' - 0"

A301

2G

2H A301

2G Sim

2H

S im

176C

174B

STOOP - SEE

STRUCTURAL

4'-6"

(EL. 1045.67)

(EL. 1043.25)

MAX

STOOP- SEE

STRUCTURAL.

E01

TEMPORARY

CONSTRUCTION

WALL. PATCH PAINT

WALLS, FLOORS,

AND CEILING AS

NECESSARY AFTER

REMOVAL.

STOOP, CONC STEPS AND

RETAINING WALL- SEE

STRUCT

10'-6 1/4" +/-

6'-0"

3D A603

A501

CUBICLE CURTAIN

TRACK ABOVE

3' -1

/2

"CONTINIOUS

MAINTENANCE

STRIP

ROOF

OVERHANG

ABOVE

3'-4" 8'-0"

6' -0

5'-0"

4E

4A

2' -6

4A

LOUVER ABOVE -

SEE MECH

LOUVER

ABOVE -

SEE MECH

CEILING MOUNTED

TRACK AND HARNESS

SYSTEM BY 11 73 01 -

ALTERNATE #2

A603

A702 2B

A702 2B

A702 2B A702

2B

M

IN

. 4 8"

C

LE

A R

FA

C

E O

F B

C S

T O

FR

O

N T

O F

TO

IL

E T. .

C O

N

FI

R M

C

LR

C O

N

FI

R M

C

LR

SHELL SPACE

4,550 SF

AREA OF

WORK

GENERAL NOTES:

FINISH FLOOR ELEV = 100'-0"

EXTERIOR DIMENSION TO EXTERIOR FACE OF WALL

SEE SPECIFICATION FOR TYPE AND LOCATION OF GYPSUM

BOARD; "X", "C", ETC.

INTERIOR CORRIDOR WALLS DIMENSIONED TO FINISH FACE

OF WALL, SPECIFIED CLEAR

INTERIOR WALLS DIMENSIONED TO CENTER OF WALL

ALL WALL TYPES TO BE 4C UNLESS NOTED OTHERWISE.

ALL COLUMNS TO BE FURRED OUT WITH 1A UNLESS NOTED

OTHERWISE.

PROVIDE MAINTENANCE STRIP AROUND ENTIRE PERIMETER

OF BUILDING AND LINK WHERE BUILDING COMES IN CONTACT

WITH TURF

SEE STRUCTURAL FOR CMU CONTROL JOINTS

ALL WALLS TO EXTEND TO STRUCTURE ABOVE, PROVIDE

DEFLECTION TRACK

NO BRICK CUTS ARE ACCEPTED AT THE OPENINGS FOR

WINDOWS, DOORS OR STOREFRONTS. 1/2 OR CUSTOM SIZE

BRICKS SHALL BE PROVIDED AS NECESSARY.

INDICATED EQUIPMENT, SEE EQUIPMENT SCHEDULEXX

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Sara Malin License No. 40063

COPYRIGHT This drawing is the copyrighted work product of Architect and reuse, modification or reproduction of these documents without express written consent of Architect is prohibited. The architectural or related services performed or furnished by the Architect for this project are provided subject to the care and skill ordinarily exercised by members of the architectural profession practicing under similar circumstances at the same time and in the same locality. Architect makes no warranties, express or implied, in connection with its services.

C

No DATEREVISION

DRAWING TITLE

APPROVED: CHIEF OF STAFF

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: CHIEF OF POLICE

APPROVED: DIRECTOR FMS DATE: APPROVED: SAFETY MANAGER DATE:

APPROVED: GEMS COORDINATOR

APPROVED: PROJECTS SECTION MANAGER

APPROVED: SERVICE LINE DIRECTOR

DATE:

DATE:

DATE: APPROVED: INFECTION CONTROL NURSE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE:

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DATE:

DATE: DRAWING NO.

DRAWN

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE

REHABILITATION CENTER

PROJECT #656-332

St. Cloud VA Health Care System

FIRST FLOOR PLAN 11/13/2018

S1430

A101

1/8" = 1'-0"A101

1 FIRST FLOOR PLAN- AREA A

NORTH

1 9/30/14 Bathroom Dimension Changes

2 6/2/15 Code Review Changes

3 9/30/16 RECORD SET

A102 1D

A102

1A

A1021B

A102

1C

41'-0"

'-0

5' -0

'-0

5' -0

1.5 MW GENERATOR

ALTERNATE #7 -

SEE ELEC

GENERATOR

BUILDING

180A

A601

A701 4A

SIM.

A701 4B

SIM.

19'-4"

7' -6

7'

-1 1"

7' -1

1"

180B

DAY TANK - SEE

MECH.

DOCKING STATION

- SEE ELEC.

3'-4" 3'-4" 34'-4"

180C

8' -8

8'

-4

5' -0

2'

-0

8"

1' -4

HM DOOR

SPLASH BLOCK

3' -5

3' -8

12'-4" 16'-0" 12'-8"

SPLASH BLOCK

FUEL OIL PIPING

TRENCH. SEE

DETAIL 1E

A102

A601

A601

A601

2'x2'x2' CONC.

SUMP. COORD.

SIZE AND

LOCATION WITH

MECH. & ELECT.

2D

A102

ARCHITECTURAL

PRECAST BAND

PREFINISHED METAL

PARAPET CAP

BEJ

FACE BRICK W/ HEADER

BRICK AT EVERY 6TH

COURSE

BEJ

SCUPPER AND

DOWNSPOUT

8" SOLDIER COURSE

INTAKE LOUVER

FACE BRICK W/

HEADER BRICK AT

EVERY 6TH COURSE

PREFINISHED METAL

PARAPET CAP

BEJ

ARCHITECTURAL

PRE-CAST BAND

2' -0

HM DOOR AND

FRAME

SOLDIER COURSE

L7

NON-ILLUMINATED EXTERIOR SIGN

VA STANDARD SIGN EN-06.06,

MESSAGE LAYOUT A

EXTERIOR

LIGHT FIXTURE

(2 THUS)

BRICK SOLDIER

COURSE

BEJ

A601

PREFINISHED METAL

PARAPET CAP

A601

BEJ

ARCHITECTURAL

PRE-CAST BAND

FACE BRICK W/ HEADER

BRICK AT EVERY 6TH

COURSE

8" SOLDIER COURSE

SPLASH BLOCK SPLASH BLOCK

DS

DS

A601

L14

EXHAUST LOUVER

ARCHITECTURAL

PRE-CAST BAND

PREFINISHED METAL

PARAPET CAP

L15

BEJ

FACE BRICK W/

HEADER BRICK AT

EVERY 6TH COURSE

2' -0

8" BRICK SOLDIER COURSE

16' - 0"

7'

4"

S

LO

P E

1/ 4"

P E

R F

T.

A601

A102

3B

A102

3D

A102 3C

SIM.

TRASH

ENCLOSURE

BEJ BEJ

2'-0" 2'-0"

14'-0" A102 4A

RECESSED

STRIKE FOR

CANE BOLT -

BOTH SIDES

BOLLARDS

A601

FACE BRICK

PREFINISHED METAL

PARAPET CAP

7'

4"

BEJBEJ

FACE BRICK

PREFINISHED METAL

PARAPET CAP

7' -0

HEAVY DUTY STEEL

HINGE - (3) PER SIDE

TUBE STEEL HINGE PIPE

CANE BOLT - (2) THUS

HEAVY DUTY SLIDE BOLT

GATE LATCH MOUNTED

3'-6" ABOVE GRADE

TRASH ENCLOSURE GATE

BY DIV. 32 31 22

PERSONAL FALL ARREST

SYSTEM CONNECTOR

(2 THUS)

SLOPE

5.75"

1/ 4"

FT

S

LO

P E

GENERATOR BELOW

SLOPE

OPENING FOR EXHAUST

STACK - VERIFY

OPENING SIZE AND

LOCATION

CONCRETE FILLED

TUBE STEEL

8"

BRICK RETURN

3"

TOWEL BAR

SD

ADJ. SHELVING

SHOWER

CURTAIN ROD

GRID

SLOPE

1/8" / FT TYP. AT ALL

FLOOR DRAINS

R 4"

FOLD DOWN

GRAB BARS

A601

1'-0"

/8

1/4" STEEL PLATE

CONTINUOUS L2X2X1/4 FRAME

WITH 1/4" X 1/2" EDGE BAR

AND ANCHORS @ 24" O.C.

CONCRETE TRENCH

#4 @ 18"

#4 LONGIT.

2'-0"

VERIFY

1'-0"

SPLIT GRATING -

COORDINATE W/ MECH.

CONTINUOUS L2X2X1/4 FRAME

WITH 1/4" X 1/2" EDGE BAR

AND ANCHORS @ 24" O.C.

CONCRETE SUMP

#4 @ 18"

#4 LONGIT.

2' -0

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Sara Malin License No. 40063

COPYRIGHT This drawing is the copyrighted work product of Architect and reuse, modification or reproduction of these documents without express written consent of Architect is prohibited. The architectural or related services performed or furnished by the Architect for this project are provided subject to the care and skill ordinarily exercised by members of the architectural profession practicing under similar circumstances at the same time and in the same locality. Architect makes no warranties, express or implied, in connection with its services.

C

No DATEREVISION

DRAWING TITLE

APPROVED: CHIEF OF STAFF

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: CHIEF OF POLICE

APPROVED: DIRECTOR FMS DATE: APPROVED: SAFETY MANAGER DATE:

APPROVED: GEMS COORDINATOR

APPROVED: PROJECTS SECTION MANAGER

APPROVED: SERVICE LINE DIRECTOR

DATE:

DATE:

DATE: APPROVED: INFECTION CONTROL NURSE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE:

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DATE:

DATE: DRAWING NO.

DRAWN

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE

REHABILITATION CENTER

PROJECT #656-332

St. Cloud VA Health Care System

PARTIAL PLANS,

ELEVATIONS &

SCHEDULES

11/13/2018

S1430

A102

1/8" = 1'-0"A102

2A GENERATOR BUILDING FLOOR PLAN

1/8" = 1'-0"A102

1A NORTH ELEVATION - GENERATOR BUILDING

1/8" = 1'-0"A102

1B EAST ELEVATION - GENERATOR BUILDING

1/8" = 1'-0"A102

1C SOUTH ELEVATION - GENERATOR BUILDING

1/8" = 1'-0"A102

1D WEST ELEVATION - GENERATOR BUILDING

EQUIPMENT LIST -

(EXISTING & NEW

1/8" = 1'-0"A102

3A TRASH ENCLOSURE PLAN

1/8" = 1'-0"A102

3B NORTH ELEVATION - TRASH ENCLOSURE

1/8" = 1'-0"A102

3C EAST/WEST ELEVATION - TRASH ENCLOSURE

NORTH

1/8" = 1'-0"A102

3D SOUTH ELEVATION - TRASH ENCLOSURE

1/8" = 1'-0"A102

2B GENERATOR ROOF PLAN

1 1/2" = 1'-0"A102

4A JAMB AT TRASH ENCLOSURE

1/4" = 1'-0"A102

4B ADL BATH

1/8" = 1'-0"A102

2C GENERATOR BUILDING RCP

1 1/2" = 1'-0"A102

1E PIPING TRENCH DETAIL

1" = 1'-0"A102

2D SUMP DETAIL AT DAY TANK

1 9/30/16 RECORD SET

NEW WORK

32" 32" 36"36"

48"

24"

32"

30"

48"

48"

WORK

RECEPTION

T-1

MUSIC

NORTH

VESTIBULE

PASS

THROUGH

LINK TO

BUILDING 51

T-2

C E

IL

IN

G L

IF

T

A601

WC STOR.

SCHEDULING

ASSESSMENT/

CONSULTATION

WAITING

A601

ANGLED SOFFIT

A602

AD101

EXPOSED

EXPOSED

EXPOSED

EXPOSED

A402

EXPOSED

SOUTH

VESTIBULE

STAFF

OP GYM

T-4

FEMALE

TOILET ROOM

PT GYM

PT CHARTING

EQUIP

STORAGE

T-5

PATIENT

TOILET

T-3

T-6

MECHANICAL

PROS

STORAGE

CORRIDOR

WAITING

JAN

GROUP

MEETING

ROOM

SOCIAL

WORKER

CONSULTATION

MALE TOILET

MALE TOILET

ROOM

CORRIDOR

ELECTRICAL

FEMALE

TOILET

T-7

A402

EXPOSED

SOILED LINEN

IT

CLEAN

UTILITY

CLEAN LINEN

ELECTRICAL

LOW

VOLTAGE

RECYCLING

HALLWAY

EXPOSED

A602

METAL PANEL CEILING SYSTEM-

AT-2

10' - 0" AFF

10' - 0" AFF

10' - 0" AFF

8' - 6"

CUBICAL CURTAIN TRACK-

TYP. ALL TREATMENT

ROOMS

9' - 6"

9' - 2"

8' - 0"

9' - 6"

8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0"

2'-10"

E Q

E Q

E Q

E Q

E Q

EQ TYP.EQ TYP.

EQ EQ EQ

ALIGN

TYP.

2'-4"

2' -2

E Q

E Q

E Q

E Q

E Q

EQ EQ

2' -2

2'-2"

2' -8

ALIGN

ALIGN

FLOOR HATCH BELOW

STEEL HOIST HOOK

TEMPORARY

PARTITION.

PATCH CEILING

AS REQUIRED TO

MATCH EXISTING.

1'-0"

2'-0"2' -0

AIR CURTAIN -SEE MECH

AIR CURTAIN - SEE MECH

1'- 0" 7' - 2"

CUH-SEE MECHANICAL

CUH - SEE MECHANICAL

1F

A401

PROVIDE SOUND

ATTENUATION

ABOVE CEILING

2' -2

" 7' - 2"

107' - 7"

107' - 9"

109' - 0"

107' - 11"

13' - 5"

3D A603

CUBICAL

CURTAIN TRACK

METAL PANEL

CEILING SYSTEM- AT-2

MECH LOUVER

MECH LOUVER

2' -8

2'

-8

8' - 4"

CUH-SEE MECHANICAL

CEILING MOUNTED

TRACK AND HARNESS

SYSTEM BY 11 73 01 -

ALTERNATE #2

7'-0"

A603

2' -0

FIELD VERIFY

CLEARANCE

REQUIRED WITH

MECHANICAL

1'-2"

8' - 0"

7' - 3"

7' - 6"

SHELL SPACE

4,550 SF

CANOPY NOT CONSTRUCTED

AREA OF

WORK

FINISHED GYP. BD.

ON SUSPENDED

METAL FRAMING

2 x 2 OR 2 x 4 ACT

ON SUSPENDED

METAL FRAMING

UN-FINISHED GYP. BD.

ATTACHED TO

UNDERSIDE OF

STRUCTURE, 1-HR

ROOF ASSEMBLY

FINISHED GYP. BD.

ATTACHED TO

UNDERSIDE OF

STRUCTURE, 1-HR

ROOF ASSEMBLY

VINYL FACED GYP. BD

LAY-IN

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Sara Malin License No. 40063

COPYRIGHT This drawing is the copyrighted work product of Architect and reuse, modification or reproduction of these documents without express written consent of Architect is prohibited. The architectural or related services performed or furnished by the Architect for this project are provided subject to the care and skill ordinarily exercised by members of the architectural profession practicing under similar circumstances at the same time and in the same locality. Architect makes no warranties, express or implied, in connection with its services.

C

No DATEREVISION

DRAWING TITLE

APPROVED: CHIEF OF STAFF

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: CHIEF OF POLICE

APPROVED: DIRECTOR FMS DATE: APPROVED: SAFETY MANAGER DATE:

APPROVED: GEMS COORDINATOR

APPROVED: PROJECTS SECTION MANAGER

APPROVED: SERVICE LINE DIRECTOR

DATE:

DATE:

DATE: APPROVED: INFECTION CONTROL NURSE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE:

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DATE:

DATE: DRAWING NO.

DRAWN

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE

REHABILITATION CENTER

PROJECT #656-332

St. Cloud VA Health Care System

REFLECTED CEILING

PLAN - FIRST FLOOR

11/13/2018

S1430

A201

1/8" = 1'-0"A201

1 FIRST FLOOR REFLECTED CEILING PLAN

CEILING HATCH PATTENS

REFLECTED CEILING GENERAL NOTES:

1. CUBICLE TRACK BY GC, CURTAIN BY OWNER

2. CEILING HEIGHTS TO BE 9'-0" AFF U.N.O.

3. DEDUCT ALTERNATE 2 IS THE ELIMINATION OF

THE CEILING LIFTS AND THE OVERGROUND GAIT

AND BALANCE TRAINING SYSTEM.

NORTH

1 10/7/15 PR-37 Gait Track Mod

2 9/30/16 RECORD SET

SWING-DOWN

GRAB BARS

CONTINUE WAINSCOT

ON ALL WALLS

SEE GENERAL

NOTES FOR WSCT

INFORMATION

RANGE-FOIO

VERIFY REQ'D

CLEARANCE WITH

OWNER

RANGE HOOD (FOIO?).

1A

A401

1E

A401

2'-1"

VERIFY

PROVIDE

MATCHING

CLOSURE

PANEL

CORNER CABINET

W/ OPEN SHELVES

1B

A401

3' -0

1'

-5

/4

2' -6

1'-6" 2'-2" 1'-6"

SS-1B CTP

LP-1 LOWER

CABS

LP-1 UPPER CABS

OPEN

UC LIGHTS

SD - FOIO

PTD - FOIO

CORNER CABINET

W/ OPEN LP-1 SHELVES

1B

A401

1A

A401

FRIDGE FOIO

DISHWASHER FOIO

SS-1B CTP

LP-1 BASE CABS

LP-1 CABS

PROVIDE LP-1 END

PANEL FOR

DISHWASHER OPENING

PROVIDE LP-1 APRON TO

CONCEAL SINK FACE

VERIFY WITH OWNER

1'-6"

MICROWAVE - FOIO

VERIFY W/ OWNER

2' - 6"

2' -6

1'

-5

/4

3' -0

2'-6" 3'-0" 1'-6" 2'-6"

RB-1 BASE - ALL SIDES

1A

A401

SIM.

ADJUSTABLE

SHELVES

A401 4E

LP-1 CABS

4" RB-1 VINYL BASE

3'-0" 3'-0"

7' -0

FILLER STRIP

2' -6

2'

-0

2' -6

COPIER-

FOIO

1A

A401

1B

A401

LP-1 CABS

LP-2 CTP

LP-1 BASE CABS

4" RB-1

VINYL BASE

3'-0"

TALL LP-1 CABINETS

W/ ADJ. SHELVES -

LOCKABLE

HR-1

WB-1

4" RB-1 VINYL BASE

4E

A401

7' -1

/4

3/

4"

3'-0" 3'-0"

PTD - FOIO

SD - FOIO

(7) ADJUSTABLE

VERTICAL DIVIDERS

30" DEEP TALL LP-1

CABINET W/ ADJUSTABLE

SHELVES

(2 '-6

" M

IN

2' -7

/4

LOCKABLE

30" DEEP LP-1

BASE CABS

LP-1 CABS

30" DEEP

LP-2 CTP

4E

A401

2'-6"2'-6"2'-6"2'-6"

3' -0

1'

-6

1B

A401

1A

A401

VIEW

OBLIQUE

MODULAR RECEPTION DESK

BY SECTION 12 31 00

VIEW

OBLIQUE

UC

REF.

BY

FFE

UC LIGHTS

SD - FOIO

PTD - FOIO

TALL LP-1 CABINETS W/

ADJ. SHELVES - LOCKABLE

CLEAR

2'-4" LOCKABLE

LP-1 CABS

LP-2 CTP

LP-1 BASE CABS

4" RB-1 VINYL

BASE,

CONTINUE IN

RECESS

4E

A401

7' -0

1'-3"3'-0"2'-4"3'-3"3'-3"

3' -0

1'

-6

2' -6

FILLER STRIP

SD - FOIO

PTD - FOIO

HAND SANITIZER - FOIO

HAMPER - FOIO

CT-3 WAINSCOT

5'-0"4" RB-1 VINYL BASE

4C

COAT HOOK

SYSTEMS FURNITURE BY DIV. 12

V E

R

IF

Y D

IM

E

N S

IO

N

S W

IT

H

S Y

S

TE

M S

F U

R N

IT

U

R E

4'-0"

4" RB-1 BASE

6' -0

A603

UC LIGHTS -

SEE ELEC.

MODULAR RECEPTION

DESK BY SECTION 12 31 00

14" DEEP LP-1

ADJUSTABLE

SHELVES

COPIER-FOIO

3E

A401

1B

A401

LP-2 CTP

LP-1

BASE

CABS

4" RB-1 VINYL

BASE

2'-6"3' -0

14" DEEP LP-1

SHELVES

COPIER-FOIO

4" RB-1

VINYL

BASE

ONE-WAY GLAZING

4' -0

2'

-2

MODULAR DICTATION STATION BY

SECTION 12 31 00

4" RB-1 VINYL BASE

F2 F2

FAAP - SEE ELECT.4" RB-1 VINYL BASE

SF2 SF1

SS-1A SILL

1A

A401

1B

A401

1C

A401

PROVIDE

MATCHING

FILLER PANELS

LP-1 CABS

LP-2 CTP,

BACKSPLASH, &

SIDESPLASH

LP-1 BASE CABS

2' -6

1'

-5

/4

3' -0

1' -6

2'-0"2'-6"FSOFFIT

1A

A401

SIM.

UC LIGHT

MICROWAVE SHELF

1A

A401

1D

A401

1B

A401

1C

A401

LP-2 CTP

FRIDGE FOIO

LP-1 BASE CABS

VERIFY WITH OWNER

2'-10"

1A

A401

SIM.

2'-8" 2'-8" 2'-8"

3' -0

2'

-0

2' -6

1' -6

LP-1 CABS

1A

A401

1B

A401

1C

A401

ELECTRIC

WATER

COOLER

4'-0"

3' -0

1'

-6

2' -6

LP-1 UPPER

CABS

LP-2 CTP,

BACKSPLASH, &

SIDESPLASH

LP-1 LOWER

CABS

ONE-WAY GLAZING

A .F

.F

4' -0

2'

-2

F2 F2

4" RB-1 BASE

ADJUSTABLE

SHELVES

4E

A401

LP-1 CABS

3'-0" 3'-0"

7' -0

FILLER STRIP

SD -

FOIO

PTD -

FOIO

A401 4F

CONTINUE

WAINSCOT

ON ALL

WALLS

(1) 4 1/4" X 4 1/4" CT-3

BULLNOSE TRIM

(1) 2 1/8" X 8 1/2"

CT-4 ACCENT BAND

(10) 4 1/4" X 4 1/4"

CT-3 FIELD TILE

(1) 4 1/4" X 8 1/2"

CT-3 COVE BASE

6' -6

3' -0

2'-0"

UC LIGHTS

BLANKET WARMER

ON CART - FOIO

EMG UNIT ON CART - FOIO

1A

A401

SOFFIT

LP-1 CABS

LP-2 CTP

LP-1 DRAWER

EQ EQ EQ EQ EQ

2' -6

3/

4"

4" RB-1 BASE

SD - FOIO

PTD - FOIO

1'-6"

A401 1A

1B

A401

SOFFIT

LP-2 CTP

LP-1 BASE

CABS

LP-1 CABS

REFER TO ELEVATION

1G/A301 FOR WAINSCOT

INFORMATION

3/ 4"

2' -6

1'

-7

/4

3' -0

2'-0"

TALL LP-1 CABINETS W/

ADJ. SHELVES -

LOCKABLE

LP-1 CABS

4" RB-1 VINYL BASE

4E

A401

3'-0" 3'-0"

7' -2

FILLER STRIP

14" DEEP LP-1

SHELVES ON

STANDARDS

LP-2 CTP

LP-1 BASE CAB4" RB-1 VINYL BASE

EQ EQ EQ EQ

3' -0

1B

A401

6' -6

CONTINUE

WAINSCOT ON

ALL WALLS

SEE GENERAL

NOTES FOR WSCT

INFORMATION

LP-1 BASE CABS &

APRON AT SINK

A401 4B

UC LIGHTS

1A

A401

4'-0"

ADJUSTABLE LP-1

SHELVES AT UPPER

LP-1 CABINETS

ADJUSTABLE COUNTER-TOPS BY

12 31 00, MODULAR CASEWORK

2' -6

7' -2

3'-0" 3'-0" 3'-0" 3'-0"

2' -6

4" RB-1 VINYL BASE

LP-1 MAILBOX

SLOTS

9 1/2" CLEAR TYP.

5" C

LE

A

R T

Y P

. LP-2 CTP

LP-1 BASE

CABS

4" RB-1

VINYL BASE

3E

A401

3'-0"

SD - FOIO

PTD ON

ADJACENT WALL-

FOIO

HAND SANITIZER - FOIO

CT-3 WAINSCOT; CONTINUE

WSCT ON ALL 3 WALLS

SEE ELEVATION

FOR WAINSCOT

INFORMATION

A301 1G

Sim

1'-6"

SD - FOIO

PTD - FOIO

HAND

SANITIZER -

FOIO

(1) 4 1/4" X 8 1/2"

CT-3 COVE BASE

AWP-1; REFER TO FINISH

PLAN FOR PANEL LENGTH

3' -0

(8) 4 1/4" X 4 1/4"

CT-3 FIELD TILES

(1) 4 1/4" X 4 1/4"

BULLNOSE TRIM

SAME TILE WSCT

TYPICAL AT ALL

TREATMENT ROOM

SINK LOCATIONS

4" CARPET BASE 3'-8"

24"X36"

MIRROR - TYP

4' -0

LP-1 CABS

ADJUSTABLE

TILTED MIRROR;

FILLER PER SPECS

SD - FOIO

OPEN

PTD - FOIO

1' -6

4"

3' -0

2'

-0

SS-1A CTP WITH

INTEGRAL SINK

LP APRON,

RETURNED TO

WALL

CONTINUE

WAINSCOT ON

ALL WALLS

SEE GENERAL

NOTES FOR WSCT

INFORMATION

1'-1 3/4"

2' -1

0"

4'-2"

2'-0" 1'-0"

1' -6

4"

1' -0

2'

-0

CONTINUE

WAINSCOT

ON ALL

WALLS

(1) 4 1/4" X 4 1/4" CT-3

BULLNOSE TRIM

(1) 2 1/8" X 8 1/2"

CT-4 ACCENT BAND

(10) 4 1/4" X 4 1/4"

CT-3 FIELD TILE

(1) 4 1/4" X 8 1/2"

CT-3 COVE BASE

BCS

A401 4F

SD -

FOIO

PTD -

FOIO

CONTINUE

WAINSCOT

ON ALL

WALLS

A401 4F

CT-3 FIELD TILE; ALL

OTHER TILES AT TOP

ROW ARE CT-3

BULLNOSE TRIM

TILE DETAIL TYP. AT

ALL VERTICAL GRAB

BAR LOCATIONS

ALL TILES AT VERTICAL

GRAB BAR ARE CT-3

BULLNOSE TRIM

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Sara Malin License No. 40063

COPYRIGHT This drawing is the copyrighted work product of Architect and reuse, modification or reproduction of these documents without express written consent of Architect is prohibited. The architectural or related services performed or furnished by the Architect for this project are provided subject to the care and skill ordinarily exercised by members of the architectural profession practicing under similar circumstances at the same time and in the same locality. Architect makes no warranties, express or implied, in connection with its services.

C

No DATEREVISION

DRAWING TITLE

APPROVED: CHIEF OF STAFF

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: CHIEF OF POLICE

APPROVED: DIRECTOR FMS DATE: APPROVED: SAFETY MANAGER DATE:

APPROVED: GEMS COORDINATOR

APPROVED: PROJECTS SECTION MANAGER

APPROVED: SERVICE LINE DIRECTOR

DATE:

DATE:

DATE: APPROVED: INFECTION CONTROL NURSE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE:

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DATE:

DATE: DRAWING NO.

DRAWN

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE

REHABILITATION CENTER

PROJECT #656-332

St. Cloud VA Health Care System

INTERIOR

ELEVATIONS

11/13/2018

S1430

A301

1/4" = 1'-0"A301

4C ADL BATH

1/4" = 1'-0"A301

4A ADL KITCHEN 1

1/4" = 1'-0"A301

4B ADL KITCHEN 2

1/4" = 1'-0"A301

1F MUSIC

1/4" = 1'-0"A301

5E OT CHARTING

1/4" = 1'-0"A301

4H OT CLINIC

1/4" = 1'-0"A301

5B OT CLINIC - SPLINT COUNTER

1/4" = 1'-0"A301

3A RECEPTION

1/4" = 1'-0"A301

4G SPEECH LAB

1/4" = 1'-0"A301

2B TYPICAL TREATMENT ROOM

1/4" = 1'-0"A301

2C TREATMENT RMS & SPEECH THERAPY - TYP.

1/4" = 1'-0"A301

3B RECEPTION 2

1/4" = 1'-0"A301

2D WORK 1

1/4" = 1'-0"A301

2E WORK 2

1/4" = 1'-0"A301

5F OT CHARTING 2

1/4" = 1'-0"A301

5D SOUTH VESTIBULE

1/4" = 1'-0"A301

1A GROUP MEETING ROOM 1/4" = 1'-0"A301

1B STAFF

1/4" = 1'-0"A301

1C OP GYM

1/4" = 1'-0"A301

1D PT GYM

1/4" = 1'-0"A301

1E PT GYM 2

1/4" = 1'-0"A301

2A TYPICAL TOILET

1/4" = 1'-0"A301

3C PROCEDURE ROOM EMG

1/4" = 1'-0"A301

3D PROCEDURE ROOM EMG 2

1/4" = 1'-0"A301

3E LOW VISION CLINIC

1/4" = 1'-0"A301

5C PT CHARTING

1/4" = 1'-0"A301

4D ADL BATH 2

1/4" = 1'-0"A301

3F LOW VISION CLINIC 2

1/4" = 1'-0"A301

2F WORK 3

1/4" = 1'-0"A301

5A OT CLINIC 2

1/4" = 1'-0"A301

1G MUSIC 2

GENERAL NOTES

1. REFER TO ELEVATION 1G/A301 FOR TREATMENT ROOM,

PROCEDURE ROOM, SPEECH THERAPY, & LPN TILE

WAINSCOT DETAILS

2. REFER TO ELEVATION 2A/A301 FOR TYPICAL TOILET

ROOM & ADL BATH TILE WAINSCOT DETAILS. TILE

WAINSCOT TO CONTINUE ALL WALLS, U.N.O.

3. PROVIDE LOCKS ON ALL SINK BASE CABINETS

4. REFER TO ELEVATION 2G/A301 FOR TYPICAL TILE DETAIL

AT VERTICAL GRAB BARS

1/4" = 1'-0"A301

4E ADL BATH 3

1/4" = 1'-0"A301

4F ADL BATH 4

SEE SHEET A403 FOR

MODULAR CASEWORK

DETAILS

SEE SHEET A403 FOR

MODULAR CASEWORK

DETAILS

SEE SHEET A403 FOR

MODULAR CASEWORK

DETAILS

1/4" = 1'-0"A301

2H FEMALE TOILET 170 (EAST)

1/4" = 1'-0"A301

2G FEMALE TOILET 170 (NORTH)

NOTE: SEE PLAN FOR

T-3 CUSTOM COUNTER

SHAPE & DIMENSIONS

1 9/25/14 ASI 5 TILE REVISIONS

2 9/30/16 RECORD SET

ROOM NOT CONSTRUCTED ROOM NOT CONSTRUCTED

ROOM NOT CONSTRUCTED

ROOM NOT CONSTRUCTED

ROOM NOT CONSTRUCTED

RECESSED CABINET

VERIFY WALL CONFIGURATION &

LOCATION W/ PLANS

MOUNT BOTTOM OF F.E.

CABINET @ 3'-0" A.F.F.

VERIFY RECESS REQ'MTS

W/ CABINET SUPPLIER

6" METAL STUDS

2"

2"

5/8" GYP BD ON STUD WALL

SURFACE MOUNTED

CORNER GUARD BY DIV 10

REFER TO PLAN

FOR WALL TYPES

FINISH PAINTING WALLS

PRIOR TO CORNER

GUARD INSTALLATION

5/8" GYP BD ON STUD WALL

FINISH PAINTING WALLS

PRIOR TO CORNER

GUARD INSTALLATION

SURFACE MOUNTED

CORNER GUARD BY DIV 10

2' -1

0" 3' -4

2' -5

TO

P

O F

C O

N

TR

O

LS

MIRROR BY DIV. 10

CENTER ON LAV.

M

IN

SOAP DISP

FOIO

PAPER TOWEL DISP

FOIO

SAN NAP DISP BY DIV 10

(SND)

FOIO

WALL HUNG VAN OR

CAB & SINK

NOTE:

PROVIDE BLOCKING AS REQ'D

(BY DIV. 10) FOR ALL WALL

MTD. ITEMS

1'-3"

REAR GRAB BAR IS 36"

UNLESS OTHERWISE

NOTED ON ELEVATIONS

MINIMUM OF 24"

NOTE:

PLUMBER TO INSTALL

W.C. BASE, SWING UP

GRAB BAR TO BE MTD.,

W.C. TANK TO BE

INSTALLED

2' -3

" T

O S

E A

T3' -0

6" 3'-0"

1'-0" 1'-0"

A

LL

W .C

.'S

TO

T

O P

SWING UP GRAB BAR

AT ADL BATHROOM

1'-0"3'-6"

3' -0

" T

O S

E A

T

8"

4"

TO

T

O P

TOILET PAPER HOLDER,

BY DIV 10 TPH

SAN NAP DISP,

BY DIV 10 SND

CLR MIN

4'-10 1/2"

3' -4

3'-4"

1' -6

3' -4

BCS (BABY

CHANGING STATION)

1" x 3" x 1/4" STL ANCHOR WELD

TO END OF HORIZ SECTION

1'-6" x 1'-4" x 1" SQUARE 11 GA STL TUBE w/ 6" x 6" x 3/16" STL GUSSET, WELD TO TUBE

3/16" x 2-1/2" TAPCON SCREWS

1"

3"

1/8" RAD

1' -4

CTP, REFER TO ELEVS & PLANS

PROVIDE BLOCKING AS REQUIRED

CLOSE ENDS & PAINT TO MATCH WALL

1'-0" @ CLOSETS

VARIES, REFER TO PLAN

FASTEN TO WALL W/ LP COVERED CLEATS &

SCREWS. PLASTIC CAPS TO MATCH LP

6"

1/

2"

5' -0

" A .F

.F

1" DIA. CHROME BAR W/ ESCUTCHEON

PLATES, REFER TO ELEVS

L.P. GUSSETS AT 36" O.C.

BLOCKING AS REQUIRED

COUNTERSINK & PLUG SCREWS,

LP ALL SURFACES

4"

R E

FE

R

T O

E

LE

V S

1/

4"

2'-0"

SCRIBE TO WALL

IF INDICATED ON ELEVS

SUPPORT

BRACKET,

SEE DETAIL

2D

A401

WD OR LP ALL EXPOSED

SURFACES,

REFER TO ELEVS

ADJ SHELF

GENERAL NOTES

12" OR 15", REFER TO CASEWORK

R E

FE

R

T O

E

LE

V S

UC LIGHT AS INDICATED

ON ELEVS, REFER TO ELEC

SHELF QUANTITY VARIES,

REFER TO CASEWORK

GENERAL NOTES

VALANCE AS INDICATED,

REFER TO ELEVS

3/ 4"

SEE ELEVATIONS/RCP FOR SOFFITS

SEE RCP

LP FACED FILLER BY DIV. 12

R E

FE

R

T O

E

LE

V S

4"

1/ 2"

SCRIBE TO WALL AS

INDICATED ON ELEVS

DRAWER

D O

O R

6"

21" ADJ.

SHELF

BASE, REFER TO RFS 3"

LP ALL

EXPOSED

SURFACES

NOTE: 30" DEEP AT

SPLINT COUNTER

R E

FE

R

T O

E

LE

V S

4"

1/ 2"

6"

SINK BY DIV 15

LP ALL EXPOSED

SURFACES

1/2"

D O

O R

3"

SCRIBE TO WALL AS

INDICATED ON ELEVS

BASE, REFER TO RFS

LP ALL

EXPOSED

SURFACES

1' -0

1'

-6

CUT OUT FOR

ELEC. OUTLET

MICROWAVE

BY OWNER

(VERIFY SIZE)

1'-3"

1'-8"

2' -6

R E

FE

R

T O

E

LE

V S

4"

3"

BASE, REFER TO RFS

REFER TO SPEC

FOR PULL STYLE

ADJUSTABLE SHELF

LP CABS BY SEC 12,

TYP

2'-0"

2' -6

4"

1/ 2"

DRAWER

DRAWER

DRAWER

E Q

E Q

E Q

LP ALL

EXPOSED

SURFACES

3"

SCRIBE TO WALL AS

INDICATED ON ELEVS

BASE, REFER TO RFS

2' -6

4"

/4

1/ 2"

FILE

DRAWER

DRAWER

PENCIL DRAWER4"

SCRIBE TO WALL,

IF INDICATED ON ELEVS

BASE, REFER TO RFS 3"

LP ALL

EXPOSED

SURFACES

3' -0

4"

BASE

21" ADJ.

SHELF

DRAWER

7' -2

1'-2"

3/4" LP VERTICAL

DIVIDERS SLOTTED

FOR REMOVEABLE

SHELVES

REMOVEABLE

1/4" PLEXIGLASS

DIVIDERS 3" O.C.

VERT

REMOVABLE 3/16" CLEAR

PLEXIGLASS SHELVES

R E

FE

R

T O

E

LE

V S

3/4" LP VERTICAL

DIVIDERS SLOTTED FOR

REMOVABLE SHELVES

1/

2"

1'-3"

LP ALL

EXPOSED

SURFACES

CONT SPACER

1/4" SCREWS

@ 16" O.C.

STEEL BLOCKING

WALL GUARD BY

DIV 10, SEE SPEC

HANDRAIL BY DIV 10,

SEE SPEC

CONT STEEL BLOCKING

REFER TO PLANS FOR

WALL TYPE

2' -1

0"

REFER TO RFS & PLAN

FOR LOCATIONS &

VARIATIONS

ANCHORAGE SHALL BE

LOCATED TO MISS STUDS

MFG'R. STD.

END CLOSURE

CORNER

GUARD

FINISHED WALL

RESILIENT CONTACT

SURFACE BUMPER

DOOR FRAME

RESILIENT CONTACT

SURFACE BUMPER

MFG'R. STD.

END CLOSURE7"

6"

7" MAX.MFG.R. REQ'D.7" MAX.6"

[1 m m

[1 m m

LE

N

G

TH

A S

R E

Q 'D

[152mm] [178mm] [178mm]

NEOPRENE CUSHION

AT EACH FASTENING

RESILIENT CONTACT

SURFACE BUMPER

ALUMINUM

ANCHOR

BRACKETS OR

CONT. RETAINER

TOGGLE BOLT

FINISHED WALL

BASE

FINISHED FLOOR

BACKING DETAIL

O5 50 00-02

1/2"

2 1/2" MAX.

8" [2 m m

C O

O R

D

IN

A

TE

W

IT

H U

S E

R S

8" M

A X

[2 m m

[13mm]

[64mm]

SEE RCP

SEE RCP

8" X 20 GA. METAL

STUDS @ 16" O.C.

SECURITY GRILL TRACK BY

DIVISI0N 8

8" X 20 GA. RUNNER

TOP AND BOTTOM.

ANCHOR TO P/C W/

POWER DRIVEN

FASTENERS @ EACH

SIDE OF EACH STUD.

ONE LAYER GYP BD

EACH SIDE OF STUD -

SHIM AS REQUIRED FOR

WIDTH.

SEE RCP

2"

CONTRACTOR SHALL

COORDINATE LOCATIONS OF

HORIZONTAL FASTENERS.

FASTEN AT BOTH

ENDS WITH MIN. 4

TAPPING SCREWS.

CUT

HORIZONTAL

FASTENER FROM

STUD

VERTICAL WALL

STUDS AT 16"

[406mm] OR 24" [610mm] O.C.

ISOMETRIC

WALL FINISH

PLAN

1.

GENERAL NOTES:

CERAMIC TILE, 1/4" HEIGHT

SOLID SURFACE THRESHOLD

SS-1A, 1/4" TO 1/8" SLOPE SET

FLUSH WITH CT, BY DIV 09

VCT, 1/8" HEIGHT

CARPET, 1/4" HEIGHT

VCT, 1/8" HEIGHT

CTA-47-H VINYL TRANSITION

STRIP, 2 1/2" WIDE

CARPET, 1/4" HEIGHT

RUBBER FLOORING, 3/8" HEIGHT

CTA-47-L VINYL TRANSITION

STRIP, 2 1/2" WIDE

SEAL SEAM BETWEEN MATERIALS

W/ CLEAR SILICONE CAULK

VCT, 1/8" HEIGHT

CTA-47-PL TRANSITION

STRIP, 4" WIDE

RUBBER FLOORING, 3/8" HEIGHT

CERAMIC TILE, 1/4" HEIGHT

SOLID SURFACE THRESHOLD, 1/4" TO

3/8" SLOPE SET FLUSH WITH CT,

BY DIV 09

RUBBER FLOORING, 3/8" HEIGHT

RUBBER FLOORING, 3/8" HEIGHT

VCT, 1/8" HEIGHT

SUBFLOOR LEVELER

LS-40, 12" WIDE

SEAL SEAM BETWEEN MATERIALS

W/ CLEAR SILICONE CAULK

ALL CASEWORK IS LAMINATE PLASTIC AS INDICATED ON

ELEVATIONS, UNLESS NOTED OTHERWISE.

ALL BASE CABINETS TO HAVE 1 ADJUSTABLE SHELF. ALL UPPER

CABINETS TO HAVE 2 ADJUSTABLE SHELVES, EXCEPT UPPER

CABINETS 24" OR LESS HIGH TO HAVE 1 ADJUSTABLE SHELF.

ALL UPPER CABINETS TO BE 15" DEEP UNLESS OTHERWISE NOTED

ON DRAWINGS. ALL BASE CABINETS TO BE 24" DEEP UNLESS

OTHERWISE NOTED ON DRAWINGS.

INSTALL FLOOR BASE TO ALL LAMINATE BASE CABINETS IN TOE

SPACE AS SCHEDULED IN ROOM FINISH SCHEDULE.

SEE SHEET A403 FOR MODULAR CASEWORK.

GENERAL NOTES AT CASEWORK:

REFER TO ELECTRICAL AND TELECOMMUNICATION

PLANS FOR POWER/DATA/VIDEO OUTLETS.

PROVIDE ADA COMPLIANT PROTECTIVE INSULATION

WRAP AT EXPOSED LAVATORY PLUMBING, TYPICAL.

VERIFY GROMMET LOCATIONS WITH OWNER.

PROVIDE BLOCKING IN WALLS AS REQUIRED.

ALL COUNTERTOPS TO HAVE 4" BACKSPLASH AND 4"

SIDESPLASH AT RETURN WALLS.

PROVIDE LOCKS ON ALL SINK BASE CABINETS.

2' -6

4"

1/ 2"

DRAWER

DRAWER

3/

4" 5"

5"

LP ALL

EXPOSED

SURFACES

3"

SCRIBE TO WALL AS

INDICATED ON ELEVS

BASE, REFER TO RFS

DRAWER

DRAWER

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Sara Malin License No. 40063

COPYRIGHT This drawing is the copyrighted work product of Architect and reuse, modification or reproduction of these documents without express written consent of Architect is prohibited. The architectural or related services performed or furnished by the Architect for this project are provided subject to the care and skill ordinarily exercised by members of the architectural profession practicing under similar circumstances at the same time and in the same locality. Architect makes no warranties, express or implied, in connection with its services.

C

No DATEREVISION

DRAWING TITLE

APPROVED: CHIEF OF STAFF

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: CHIEF OF POLICE

APPROVED: DIRECTOR FMS DATE: APPROVED: SAFETY MANAGER DATE:

APPROVED: GEMS COORDINATOR

APPROVED: PROJECTS SECTION MANAGER

APPROVED: SERVICE LINE DIRECTOR

DATE:

DATE:

DATE: APPROVED: INFECTION CONTROL NURSE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE:

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DATE:

DATE: DRAWING NO.

DRAWN

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE

REHABILITATION CENTER

PROJECT #656-332

St. Cloud VA Health Care System

INTERIOR DETAILS 11/13/2018

S1430

A401

1 1/2" = 1'-0"A401

3A FIRE EXTINGUISHER CABINET - RECESSED

3" = 1'-0"A401

3C CORNER GUARD, SURFACE MOUNTED @ END OF WALL

3" = 1'-0"A401

3D CORNER GUARD, SURFACE MOUNTED @ CORNER OF WALL

1/2" = 1'-0"A401

4F TYP. TOILET ROOM FIXTURE DIMENSIONS

3/4" = 1'-0"A401

2D SUPPORT BRACKET

1 1/2" = 1'-0"A401

2E SHELF

3/4" = 1'-0"A401

2B 24"D COUNTER

3/4" = 1'-0"A401

1A TYP. WALL CABINET 3/4" = 1'-0"A401

1B 24"D BASE CAB - DOOR/DRAWER

3/4" = 1'-0"A401

1C 24"D SINK BASE

3/4" = 1'-0"A401

1D MICROWAVE CAB

1" = 1'-0"A401

4E 24"D STORAGE CABINET

3/4" = 1'-0"A401

1E 24" BASE CAB./3 DRAWERS

3/4" = 1'-0"A401

2A 24"D BASE CAB - FILE/DRAWER/PENCIL

3/4" = 1'-0"A401

4D 24"D 36"H BASE CAB./MAIL SLOTS

3/4" = 1'-0"A401

3E 15"D FORM SLOTS

1 1/2" = 1'-0"A401 3B TYP HANDRAIL w/ BUMPER 3F WALL GUARD

2F WALL GUARD SECTION - NTS

NTS

1 1/2" = 1'-0"A401

1F SECURITY GRILL SUPPORT

4A

ANCHORAGE- GRAB BARS AND

CABINATES

3" = 1'-0"A401

5A CERAMIC TILE TO VCT

3" = 1'-0"A401

5C CARPET TO VCT

3" = 1'-0"A401

5E CARPET TO RUBBER FLOORING

3" = 1'-0"A401

5D RUBBER FLOORING TO VCT

3" = 1'-0"A401

5B CERAMIC TILE TO RUBBER FLOORING

3" = 1'-0"A401

5F SUBFLOOR LEVELER SYSTEM

6A VESTIBULE FLOOR GRILL

NTS

NTS

3/4" = 1'-0"A401

4B INT DTL - CASEWORK - BASE CAB, 4 DRAWERS

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Sara Malin License No. 40063

COPYRIGHT This drawing is the copyrighted work product of Architect and reuse, modification or reproduction of these documents without express written consent of Architect is prohibited. The architectural or related services performed or furnished by the Architect for this project are provided subject to the care and skill ordinarily exercised by members of the architectural profession practicing under similar circumstances at the same time and in the same locality. Architect makes no warranties, express or implied, in connection with its services.

C

No DATEREVISION

DRAWING TITLE

APPROVED: CHIEF OF STAFF

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: CHIEF OF POLICE

APPROVED: DIRECTOR FMS DATE: APPROVED: SAFETY MANAGER DATE:

APPROVED: GEMS COORDINATOR

APPROVED: PROJECTS SECTION MANAGER

APPROVED: SERVICE LINE DIRECTOR

DATE:

DATE:

DATE: APPROVED: INFECTION CONTROL NURSE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE:

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DATE:

DATE: DRAWING NO.

DRAWN

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE

REHABILITATION CENTER

PROJECT #656-332

St. Cloud VA Health Care System

INTERIOR DETAILS -

MODULAR

CASEWORK

11/13/2018

S1430

A403

1/2" = 1'-0"A403

1 TREATMENT RM MODULAR CASEWORK

3/8" = 1'-0"A403

2 RECEPTION DESK MODULAR CASEWORK

3/8" = 1'-0"A403

3 OT CHARTING RM MODULAR CASEWORK

3/8" = 1'-0"A403

4 PT CHARTING RM MODULAR CASEWORK

PROVIDE SEPARATE CONDUITS

FOR NORMAL & EMERGENCY

POWER

1 9/30/16 RECORD SET

ROOM NOT CONSTRUCTED

LEVEL 0

100' - 0"

ROOF SLAB

115' - 9"

CRAWL SPACE

93' - 0"

MECH BASEMENT

88' - 0"

PROVIDE DEFLECTION TRACK

AT TOP OF WALL - TYP. A601

OPP.

LEVEL 0

100' - 0"

ROOF SLAB

115' - 9"

CRAWL SPACE

93' - 0"

MECH BASEMENT

88' - 0"

1' -0

8"

6' -0

2'

-8

8 1/2

SHEET

WATERPROOFING

2" RIGID FOUNDATION

INSULATION

CONC. FOUNDATION -

SEE STRUCT.

CONC. SLAB ON GRADE -

SEE STRUCT.

3" ROCK MULCH ON

LANDSCAPE FABRIC

PLASTIC EDGING

2'-8"

FACE BRICK

CONTINUOUS CAVITY DRAINAGE

MATERIAL

3" CAVITY WALL INSULATION

(R-15 MIN.)

AIR/VAPOR BARRIER

6" CMU

5/8" GYP BD ON METAL FURRING

AT 16" O.C. TOPPING ON PRECAST

PLANK - SEE STRUCTURAL

BRICK SOLDIER

COURSE

4 1/2" PRECAST

ARCHITECTURAL

CONCRETE

LIGHT GUAGE

TRUSSES BY

05 40 00

PRECAST BEAM -

SEE STRUCTURAL

PRECAST PLANK -

SEE STRUCTURAL

ACT - SEE RCP

COLUMN BEYOND

COLUMN AND

FURRING BEYOND

ASPHALT SHINGLE SYSTEM

METAL DECKING - SEE

STRUCTURAL

5/8" PLYWOOD SHEATHING

AIR/VAPOR BARRIER

PREFINISHED

FACIA

GRID

PRECAST SILL

A701 2A

A701 3A

A701 3B

GUTTER

DRIP EDGE

A701 2B

1/2" EXPANSION

JOINT MATERIAL

VAPOR BARRIER OVER

6" GRANULAR FILL

6" SCREEDED

ON-SITE SOIL

VAPOR BARRIER OVER

6" GRANULAR FILL

AT MECHANICAL BASEMENT

SEE CIVIL FOR GRADING

BLOWN IN INSULATION

FACE BRICK

CONT. CAVITY

DRAINAGE MATERIAL

3" RIGID INSULATION

AIR/VAPOR BARRIER

8" CMU

CONC. SLAB -

SEE STRUCT.

6" COMPACTED

GRANULAR FILL

1/2" EXPANSION

JOINT MATERIAL

FOUNDATION - SEE

STRUCT.

FULLY ADHERED EPDM

MEMBRANE ROOF OVER

ROOR INSULATION

OVER PRECAST PLANK

CONT. CLEAT

PREFINISHED METAL

CAP FLASHING

TREATED WD

BLOCKING

SLOPE

PLANK BEARING

SEE STRUCT.

T.O. CMU

16'-4"

SHEET

WATERPROOFING

2" RIGID FOUNDATION

INSULATION

AIR/VAPOR BARRIER, LAP OVER

THRU-WALL FLASHING

CONT MTL DRIP

EDGE

THRU WALL FLASHING CUT

FLUSH w/ FACE OF WALL LAP

& SEAL ALL JOINTS DAM ALL

END CONDITIONS

CONT CAVITY DRAINAGE MATERIAL

FULL THICKNESS OF CAVITY

GROUT SOLID

WEEP HOLE WICK

T.O. FOOTING

SEE STRUCT.

VAPOR BARRIER

1' -0

4 3/4"

'-8

PRECAST

ARCHITECTURAL

CONCRETE

(SEE

FOR PROFILE DIMS)

B.O. BAND

2'-0"

1 3/8"

1"MAX OVERHANG -

1"

3A

A701

LEVEL 0

100' - 0"

ROOF SLAB

115' - 9"

CRAWL SPACE

93' - 0"

GRID

A701 2A

A701 3A

A701 3B

SHEET

WATERPROOFING

2" RIGID FOUNDATION

INSULATION

CONC. FOUNDATION -

SEE STRUCT.

FACE BRICK

CONTINUOUS CAVITY

DRAINAGE MATERIAL

3" CAVITY WALL

INSULATION (R-15 MIN.)

AIR/VAPOR BARRIER

6" CMU

5/8" GYP BD ON METAL

FURRING AT 16" O.C.

(SEE PLAN FOR TYPE)

TOPPING ON PRECAST

PLANK - SEE STRUCTURAL

PRECAST SILL

SEE FOR MAINTENANCE

STRIP TYP. NOTES

A601

BRICK SOLDIER

COURSE

ACT - SEE RCP

2'-10"2'-3 3/8"

A702 2D

A702 1D

5' -8

9'

-4

2' -8

PRECAST BEAM -

SEE STRUCTURAL

PRECAST PLANK -

SEE STRUCTURAL

6" SCREEDED

ON-SITE SOIL

VAPOR BARRIER OVER

6" GRANULAR FILL

T.O. FOOTING

SEE STRUCT.

SIM.

SEE CIVIL FOR GRADING

CONT. CLEAT

PREFINISHED METAL

CAP FLASHING

TREA…