ATTACHMENT A - 5 of11 501-17-105 Dwg Arch2-07-20-22.pdf

PDF 13 MB Posted

Attached to
Project 501-17-105: Upgrade Energy Plant Equipment Infrastructure
Solicitation number
36C26223B0010
Issued by

About this file

This notification provides details for an upcoming solicitation for Project 501-17-105: Upgrade Energy Plant Equipment Infrastructure at the New Mexico VA Healthcare System. The solicitation will be issued via Contract Opportunities at SAM.gov on or around July 15, 2023 for general construction, alterations, mechanical, electrical and utility systems work. The project scope includes renovation, new construction, equipment replacements and utility modifications to address deficiencies at Building 43, the Central Utility Plant. The magnitude of work is estimated between $10-20 million. The solicitation will be set aside 100% for Service-Disabled Veteran-Owned Small Businesses listed in VetCert. The NAICS code is 236220 for Commercial and Institutional Building Construction. A site visit will be scheduled after solicitation release. The point of contact is Maria Cruz-Thompson, Contracting Specialist at the Network Contracting Office 22 in Long Beach, California.

View the file

Other files

File Type Posted
C01 AWARD NOTIFICATION 36C26223B0010 .pdf PDF
C01 36C26223C0246 AWARD NOTIFICATION.pdf PDF
S06 36C26223B0010 0004.docx DOCX document
S06 36C26223B0010 0003.docx DOCX document
S06 36C26223B0010 0002.pdf PDF
ATTACHMENT 1 - SIGN-IN SHEET 36C26223B0010.pdf PDF
S06 36C26223B0010 0001.pdf PDF
ATTACHMENT A - 6 of11 501-17-105 Dwg-Arch3 07-20-22.pdf PDF
ATTACHMENT B - 501-17-105 Specifications 100 percent 07-20-22.pdf PDF
ATTACHMENT A - 4 of11 501-17-105 Dwg Arch1 07-20-22.pdf PDF
ATTACHMENT D - RFI FORM 501-17-105.docx DOCX document
ATTACHMENT A - 10 of11 501-17-105 Dwg Elec 1-2 07-20-22.pdf PDF
ATTACHMENT E - WAGE DETERMINATION - NM20230044 06-09-2023.pdf PDF
ATTACHMENT A - 3 of11 501-17-105 Dwg Struc 07-20-22.pdf PDF
ATTACHMENT A - 2 of11 501-17-105 Dwg Civil 07-20-22.pdf PDF
ATTACHMENT C - SCOPE OF WORK - 501-17-105.pdf PDF
ATTACHMENT A - 1of11 501-17-105 DwgGen 07-20-22.pdf PDF
ATTACHMENT A - 7 of11 501-17-105 Dwg Plumb 07-20-22.pdf PDF
ATTACHMENT A - 8 of11 501-17-105 Dwg Mech1 07-20-22.pdf PDF
ATTACHMENT A - 11 of11 501-17-105 Dwg Elec 2-2 07-20-22.pdf PDF
ATTACHMENT A - 9 of11 501-17-105 Dwg-Mech2 07-20-22.pdf PDF
S02 36C26223B0010 .docx DOCX document
S03. Pre-Solicitaiton Notice 36C26223B0010.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES

A. CONTRACTOR TO AVOID ALL PLANT SHUT DOWNS.

B. CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY UTILITIES.

C. CONTRACTOR TO COORDINATE WITH RECENT ROOF INSTALLATION

WARRANTY REQUIREMENTS TO ENSURE NO VIOLATIONS OCCUR.

CONTRACTOR TO EMPLOY A CERTIFIED ROOFING INSPECTOR MEETING THE

REQUIREMENTS OF THE INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL

BE REQUIRED TO BE CORRECTED PRIOR TO CLOSE OUT.

D. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE

RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.

PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT

WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY

MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.

E. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND FIRE

PROTECTION PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL

SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS

AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

F. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD

VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM

THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE

LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE

MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD

CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION

DOCUMENTS.

G. COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL TRADES PRIOR TO

INSTALLATION.

H. GALVANIC PROTECTION REQUIRED AT CONNECTIONS BETWEEN ALL

DISSIMILAR METALS.

I. ANY FLOOR, WALL, OR CEILING CUTTING THAT IS REQUIRED TO COMPLETE

THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND RETURN

TO MATCH EXISTING CONDITIONS AND FINISHES.

KEYNOTES

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

E D C B A

LEVEL_00

-12' - 0"

ROOF LEVEL

26' - 6"

E1

A-301

E1

A-301

35 35

A

L39

C1

A-301

C1

A-301

BASE

BID

B9

A-551

L115

CJ

EP-2EP-2

EP-2

EP-2

EP-2 EP-2

EP-2

A

WL-3

WL-4

'-3

3' -6

CJ

C J

C J

7A

LI

G

H T

F

IX

T U

R E

9' -6

LI

G

H T

F

IX

T U

R E

9' -6

CJ

F

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

123456

LEVEL_00

-12' - 0"

ROOF LEVEL

26' - 6"

C4

A-301

C4

A-301

A

12 12

'-9

/2

137 138

10095129

L39

BEYOND

'-5

/4

CJ

CJ

EP-2

CREDIT EQ-8 DAYLIGHTING AND QUALITY VIEWS

INSTALL SKYLIGHTS AND CLERESTORY WINDOWS

SEE SHEET A-121C

E4

A-301

E4

A-301

5.8 LIGHTING FEATURES

5.8.6 65% ACCESS TO DAYLIGHTING

EP-1

EP-2

EP-2

EP-2

3' -6

WL-2

'-1

1" 14 '-0

8' -0

9' -6

EP-1

CIP-1

TRANSLUCENT PANEL

WINDOW SYSTEM

TL-1

ARCHITECTURAL COLOR PALETTE

EXTERIOR INSULATION

FINISHING SYSTEM

CAST IN PLACE

CONCRETE

CONCRETE

MASONRY UNIT

(BURNISHED)

CMU-1

VISION GLASS

BRONZE TO

MATCH EXISTING

GL-1

NOTE: MATERIALS ARE PROVIDED AS THE BASIS OF DESIGN,

ALL MATERIAL SUBSTITUTIONS ARE SUBJECT TO OWNERS

APPROVAL.

EXTERIOR ACCENT

PAINT, ALL TRIM, ALL

REVEALS, ALL

DOORS(SWING AND

ROLL UP) ALL DOOR

TRIM AND WINDOW

TRIM

EP-2

SLATE GRAY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural and Subconsultants:

NOT FOR

CONSTRUCTION

2058 S Dobson Rd., Suite 10, Mesa, AZ 85202

(480) 454-6408 www.unitedstr.com

B

IM

/5

-1

-1

O p ti m iz e

B

E n e rg y P la n t

/5

-1

-1

.4

.A

R C

H .r v t

/2 /2

:5

:2

P M

A-201

EXTERIOR BUILDING ELEVATIONS - NORTH &

EAST

TRIPLE C THE A/E GROUP

2266 S. Dobson Road, Suite 200

Mesa, AZ 85202

(928) 499-3225

Mat Perkins

P2S ENGINEERING, INC.

5000 E. Spring Street

8th Floor

Long Beach, CA 90815-5218

Contact: Mikhail Fuks

UPGRADE ENERGY PLANT

EQUIPMENT INFRASTRUCTURE

(BLDG. 43 & 43A)

1501 SAN PEDRO SE ALBUQUERQUE, NM 87108

501-17-105

11/25/2019 M. PERKINS K.

MCDERMOTT

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0" C2

EXTERIOR ELEVATION - NORTH

1/8" = 1'-0" F2

EXTERIOR ELEVATION - EAST

1 NEW METAL PANEL WALL SYSTEM TO MATCH EXISTING INSULATED METAL PANEL

SET IN EXISTING HOLLOW METAL FRAME, PAINT EP-2

2 NEW STAIRCASE TO GENSET MEZZANINE, REFER TO A-701 AND A-702 FOR

ADDITIONAL INFORMATION

3 NEW MECHANICAL EXHAUST, REFER TO MECHANICAL SHEETS FOR ADDITIONAL

INFORMATION IN STAINLESS STEEL FINISH

4 NEW ALUMINUM WINDOW IN NEW CMU, BRONZE GLAZING TO MATCH EXISTING,

SEE EP-2 AND GL-1

5 NEW EFIS WALL SYSTEM, TO MATCH EP-1

6 NEW LOUVER SCREEN, ANODIZED ALUMINUM FACTORY FINISH

7 THERMAL ENERGY STORAGE TANK, REFER TO MECHANICAL SHEETS FOR

ADDITIONAL INFORMATION

8 SCREEN WALL HIDDEN FOR CLARITY, REFER TO SHEET A-620, SEE EP-2

9 NEW SKYLIGHT, SEE TL-1

10 NEW VISION GLASS, BRONZE GLAZING TO MATCH EXISTING, SEE EP-2 AND GL-1

12 NEW TRANSLUCENT PANEL IN NEW CMU, SEE TL-1

13 NEW TRANSLUCENT PANEL IN EXISTING STUCCO, SEE TL-1

14 NEW HM DOOR IN EXISTING STUCCO

15 EXISTING UTILITY TUNNEL TO REMAIN

16 EXISTING PARAPET COPING AND FLASHING TO BE REMOVED AND REPLACED

WITH ROOFING, SEE EP-1

17 NEW LOUVER SCREEN, REFER TO A-620 FOR ADDITIONAL INFORMATION,

ANODIZED ALUMINUM FACTORY FINISH

18 EXISTING STUCCO SHALL BE REPAIRED AND BUILDING PAINTED TO MATCH EP-1

FINISH COLOR

19 EXISTING METAL PANEL ROOF SYSTEM TO REMAIN

EXISTING STUCCO AT FENESTRATION

EXISTING STUCCO AT PENETRATIONS

EXISTING STUCCO, ENLARGED

EXISTING STUCCO TO BE REPAIRED

REPAIR CRACKS AND

JOINTS IN EXISTING

STUCCO AS NECESSARY

FOR NEW PAINT FINISH,

SEE IMAGE BELOW FOR

ENLARGEMENT

CLEAN EXISTING JOINTS

IN STUCCO AS

NECESSARY FOR NEW

PAINT FINISH

INSPECT AND REPAIR

SEALS ON ALL

PENETRATIONS FOR NEW

PAINT FINISH

INSPECT AND REPAIR

DAMAGED STUCCO AT BASE,

CORNERS, SEAMS AND

JOINTS. REPAIR ALL DEFECTS

PRIOR TO NEW PAINT FINISH

Revisions: Date:

0 4'-0" 8'-0" 16'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

7/20/2022

MATHEW PERKINS

NO.005843

07/20/2022

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

EDCBA

LEVEL_00

-12' - 0"

ROOF LEVEL

26' - 6"

E1

A-301

E1

A-301

C1

A-301

C1

A-301

L39

L115

141140140

A-511

F4

BEYOND

BEYOND

5'-6" 9'-0" 10'-0" 1'-0"

D2

A-511

EP-2

EP-2

CJ

C J

C J

CJ

18'-0" 2'-1" 13'-5"

CJ

LI

G

H T

F

IX

T U

R E

9' -6

'-9

'-0

'-0

NEW

SURVEILANCE

CAMERA

NEW

SURVEILANCE

CAMERA

EP-2

EP-2

2B

3C

'-0

9' -8

3'

-6

GENERAL NOTES

A. CONTRACTOR TO AVOID ALL PLANT SHUT DOWNS.

B. CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY UTILITIES.

C. CONTRACTOR TO COORDINATE WITH RECENT ROOF INSTALLATION

WARRANTY REQUIREMENTS TO ENSURE NO VIOLATIONS OCCUR.

CONTRACTOR TO EMPLOY A CERTIFIED ROOFING INSPECTOR MEETING THE

REQUIREMENTS OF THE INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL

BE REQUIRED TO BE CORRECTED PRIOR TO CLOSE OUT.

D. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE

RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.

PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT

WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY

MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.

E. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND FIRE

PROTECTION PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL

SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS

AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

F. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD

VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM

THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE

LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE

MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD

CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION

DOCUMENTS.

G. COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL TRADES PRIOR TO

INSTALLATION.

H. GALVANIC PROTECTION REQUIRED AT CONNECTIONS BETWEEN ALL

DISSIMILAR METALS.

I. ANY FLOOR, WALL, OR CEILING CUTTING THAT IS REQUIRED TO COMPLETE

THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND RETURN

TO MATCH EXISTING CONDITIONS AND FINISHES.

KEYNOTES

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

1 2 3 4 5 6

LEVEL_00

-12' - 0"

ROOF LEVEL

26' - 6"

C4

A-301

C4

A-301

A

'-3

110 109 108 107110

BEYOND

BEYOND

E4

A-301

E4

A-301

B

B

A

A

8' -0

WL-1

CJ

C J

C J

LI

G

H T

F

IX

T U

R E

9' -6

LI

G H

T F

IX

T

U R

E 8'

-6

3' -6

'-5

/4

'-0

'-8

/8

12'-0" 2'-0" 21'-6" 2'-0" 17'-0" 2'-0" 17'-3"2'-1" 12'-0"

L39

BEYOND

8' -0

WL-6

EP-1

CIP-1

TRANSLUCENT PANEL

WINDOW SYSTEM

TL-1

ARCHITECTURAL COLOR PALETTE

EXTERIOR INSULATION

FINISHING SYSTEM

CAST IN PLACE

CONCRETE

CONCRETE

MASONRY UNIT

(BURNISHED)

CMU-1

VISION GLASS

BRONZE TO

MATCH EXISTING

GL-1

NOTE: MATERIALS ARE PROVIDED AS THE BASIS OF DESIGN,

ALL MATERIAL SUBSTITUTIONS ARE SUBJECT TO OWNERS

APPROVAL.

EXTERIOR ACCENT

PAINT, ALL TRIM, ALL

REVEALS, ALL

DOORS(SWING AND

ROLL UP) ALL DOOR

TRIM AND WINDOW

TRIM

EP-2

SLATE GRAY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural and Subconsultants:

NOT FOR

CONSTRUCTION

2058 S Dobson Rd., Suite 10, Mesa, AZ 85202

(480) 454-6408 www.unitedstr.com

B

IM

/5

-1

-1

O p ti m iz e

B

E n e rg y P la n t

/5

-1

-1

.4

.A

R C

H .r v t

/2 /2

:5

:4

P M

A-202

EXTERIOR BUILDING ELEVATIONS - SOUTH &

WEST

TRIPLE C THE A/E GROUP

2266 S. Dobson Road, Suite 200

Mesa, AZ 85202

(928) 499-3225

Mat Perkins

P2S ENGINEERING, INC.

5000 E. Spring Street

8th Floor

Long Beach, CA 90815-5218

Contact: Mikhail Fuks

UPGRADE ENERGY PLANT

EQUIPMENT INFRASTRUCTURE

(BLDG. 43 & 43A)

1501 SAN PEDRO SE ALBUQUERQUE, NM 87108

501-17-105

11/25/2019 M. PERKINS K.

MCDERMOTT

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0" C2

EXTERIOR ELEVATION - SOUTH

1/8" = 1'-0" F2

EXTERIOR ELEVATION - WEST

1 NEW LOUVER SCREEN, ANODIZED ALUMINUM FACTORY FINISH

2 NEW STAIRCASE, SEE EP-2

3 NEW MECHANICAL EXHAUST, REFER TO MECHANICAL SHEETS FOR ADDITIONAL

INFORMATION IN STAINLESS STEEL FINISH

4 NEW TRANSLUCENT PANEL IN EXISTING STUCCO, SEE TL-1

5 NEW EFIS WALL SYSTEM, TO MATCH EP-1

6 EXISTING STAIRCASE TO REMAIN

7 KALWALL WALL FACADE

8 EXISTING DETACHED ADJACENT BUILDING HIDDEN FOR CLARITY

9 NEW SCUPPER AND DOWNSPOUT, SEE EP-2

10 NEW SKYLIGHT, SEE TL-1

11 NEW TRANSLUCENT PANEL IN EXISTING STUCCO, SEE TL-1

12 NEW HM DOOR IN EXISTING STUCCO, BASE BID

13 EXISTING TO REMAIN

14 NEW STAIRCASE TO GENSET MEZZANINE, BASE BID. REFER TO A-701 AND A-702

FOR ADDITIONAL INFORMATION

15 EXISTING STUCCO SHALL BE REPAIRED AND BUILDING PAINTED TO MATCH DRY

RIVER

16 FUTURE NEW PIPE PENETRATIONS THROUGH WALL, SEE MECHANICAL PLUMBING

DRAWINGS

Revisions: Date:

EP-2 EP-2

EP-2

EP-2

0 4'-0" 8'-0" 16'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

EP-2

7/20/2022

MATHEW PERKINS

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

E D C B A

LEVEL_00

-12' - 0"

ROOF LEVEL

26' - 6"

E1

A-301

E1

A-301

ENGINEERING

CONTROL

CENTER

111111

CHILLER

ROOM

MA-109MA-109

OFFICE

MA-203MA-203

CORRIDOR

MA-202MA-202

CHILLER

ROOM

MA-109MA-109

8 1

A-351

F1

A-351

F3

CORRIDOR

MA-122MA-122

C1

A-301

C1

A-301

9' -8

D6

A-501

43-P9

1.8 ENVELOPE

CMU WALLS SHOULD BE R-9.5 MINIMUM,

CMU WALLS BELOW GRADE SHOULD BE R-7.5,

FLOORS, HEATED SLABS R-15 FOR 24" BELOW,

R-5 UNDER FULL SLAB

4' -8

7'

-4

A-551

B5

A-551

C5

B

A-511

B5

LI

G

H T

F

IX

T U

R E

'-2

S E

C U

R

IT

Y C

A M

E R

A

'-2

'-0

43-WCCH-343-WCCH-1

F

GENERAL NOTES

A. CONTRACTOR TO AVOID ALL PLANT SHUT DOWNS.

B. CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY UTILITIES.

C. CONTRACTOR TO COORDINATE WITH RECENT ROOF INSTALLATION

WARRANTY REQUIREMENTS TO ENSURE NO VIOLATIONS OCCUR.

CONTRACTOR TO EMPLOY A CERTIFIED ROOFING INSPECTOR MEETING THE

REQUIREMENTS OF THE INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL

BE REQUIRED TO BE CORRECTED PRIOR TO CLOSE OUT.

D. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE

RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.

PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT

WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY

MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.

E. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND FIRE

PROTECTION PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL

SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS

AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

F. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD

VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM

THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE

LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE

MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD

CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION

DOCUMENTS.

G. COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL TRADES PRIOR TO

INSTALLATION.

H. GALVANIC PROTECTION REQUIRED AT CONNECTIONS BETWEEN ALL

DISSIMILAR METALS.

I. ANY FLOOR, WALL, OR CEILING CUTTING THAT IS REQUIRED TO COMPLETE

THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND RETURN

TO MATCH EXISTING CONDITIONS AND FINISHES.

KEYNOTES

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

1 2 3 4 5 6

ROOF LEVEL

26' - 6"

FOUNDATION

-2' - 0"

C4

A-301

C4

A-301

GENERATOR

ROOM

MA-106MA-106

BOILER

PLANT

MA-108MA-108

CHILLER

ROOM

MA-109MA-109

1'-1"19'-11"

9D

110'-0"

25'-0" .23'-6" 23'-6" 19'-0" 19'-0"

7F

A-511

F6

A-551

B9

'-5

/4

'-3

/2

'-6

'-0

E4

A-301

E4

A-301

NEW PIPE

PENETRATIONS

THROUGH WALL

NEW

SURVEILANCE

CAMERA

1'-1"

9C

8' -0

A-513

D3

43-WCCH-1

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

LEVEL_00

-12' - 0"

ROOF LEVEL

26' - 6"

SECOND_FLOOR_BEAM

10' - 11"

FOUNDATION

-2' - 0"

C4

A-301

C4

A-301

LOUNGE

116116

CORRIDOR

MA-122MA-122

CORRIDOR

117117

HOUSEKEEPING

AIDS

CLOSET

112112

9' -0

8' -0

8' -0

53' - 5 3/16"

A-351

F7

A-351

E5

'-6

/4

'-9

/2

" 11 11

E

V V ITEM - VA SUPPLIED & INSTALLED

V C ITEM - VA SUPPLIED &

CONTRACTOR INSTALLED

C C ITEM - CONTRACTOR SUPPLIED &

INSTALLED

FURNITURE, FIXTURE, & EQUIPMENT

INDICATOR

A1000

EQUIPMENT / FURNITURE LEGEND

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

E D C B A

LEVEL_00

-12' - 0"

ROOF LEVEL

26' - 6"

FOUNDATION

-2' - 0"

CT_FRAME

30' - 6"

E1

A-301

E1

A-301

C1

A-301

C1

A-301

SUPPLY

ROOM

MA-105MA-105

GENERATOR

ROOM

MA-106MA-106

ELECTRICAL

ROOM

MA-107MA-107

STORAGE

MA-121MA-121

NEW

ELECTRICAL

MA-211MA-211

A-551

B5

A-551

C5

A-521

F1

A-521

E6

LI

G

H T

IN

G

'-9

/4

LI

G

H T

IN

G

9' -9

D3

A-513

A-512

B4

EXISTING ELEC EQUIPMENT TO REMAIN,

BASE BID

F

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural and Subconsultants:

KEY PLAN

NOT FOR

CONSTRUCTION

A B

C

B

2058 S Dobson Rd., Suite 10, Mesa, AZ 85202

(480) 454-6408 www.unitedstr.com

B

IM

/5

-1

-1

O p ti m iz e

B

E n e rg y P la n t

/5

-1

-1

.4

.A

R C

H .r v t

/2 /2

:5

:1

P M

A-301

ARCHITECTURAL BUILDING SECTIONS

TRIPLE C THE A/E GROUP

2266 S. Dobson Road, Suite 200

Mesa, AZ 85202

(928) 499-3225

Mat Perkins

P2S ENGINEERING, INC.

5000 E. Spring Street

8th Floor

Long Beach, CA 90815-5218

Contact: Mikhail Fuks

UPGRADE ENERGY PLANT

EQUIPMENT INFRASTRUCTURE

(BLDG. 43 & 43A)

1501 SAN PEDRO SE ALBUQUERQUE, NM 87108

501-17-105

11/25/2019 M. PERKINS K.

MCDERMOTT

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0" C4

BUILDING SECTION - TRANSVERSE SECTION AT NEW ADDITION

1/8" = 1'-0" E1

BUILDING SECTION - LONGITUDINAL SECTION AT EXISTING PLANT

1 NEW LOUVER SCREEN, ANODIZED ALUMINUM FACTORY FINISH

2 NEW EXHAUST VENTILATORS, REFER TO MECHANICAL SHEETS FOR ADDITIONAL

INFORMATION

3 NEW EFIS WALL SYSTEM

4 NEW ANGLED GYPSUM WALLBOARD SOFFIT FOR CONTROL MONITORS, REFER TO

A-531 FOR ADDITIONAL INFORMATION

5 NEW MECHANICAL EXHUAST, REFER TO MECHANICAL SHEETS FOR ADDITIONAL

INFORMATION

6 NEW DOWNSPOUT

7 NEW GENSET, REFER TO MECHANICAL SHEETS FOR ADDITIONAL INFORMATION,

PHASE 1

8 THERMAL ENERGY STORAGE TANK, REFER TO MECHANICAL SHEETS FOR

ADDITIONAL INFORMATION

9 NEW ROOF TOP DEDICATED OUTDOOR AIR SYSTEM, REFER TO MECHANICAL

SHEETS FOR ADDITIONAL INFORMATION

10 REMOVE WIND-GIRT FOR NEW FLOOR, REFER TO STRUCTURAL SHEETS FOR

ADDITIONAL INFORMATION, PHASE 1

11 NEW SKYLIGHT

12 NEW SCREEN WALL

13 NEW 1-HR RATED WALL AND WINDOW SYSTEM

14 NEW STEEL FRAMING, SEE STRUCTURAL

15 NEW BIRD SCREEN OVER COOLING TOWER TO MATCH EXISTING

17 EXISTING STEEL FRAMING TO BE REMOVED

18 PAINT ALL EXPOSED STEEL IN SPACE TO MATCH SPECIFIED WALL COLOR

1/8" = 1'-0" C1

BUILDING SECTION - LONGITUDINAL

C4

C1

F4

C4

F4

1/8" = 1'-0" E4

BUILDING SECTION - NEW ELECTRICAL ROOM

Revisions: Date:

0 4'-0" 8'-0" 16'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

7/20/2022

MATHEW PERKINS

B. CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY UTILITIES.

C. CONTRACTOR TO COORDINATE WITH RECENT ROOF INSTALLATION

WARRANTY REQUIREMENTS TO ENSURE NO VIOLATIONS OCCUR.

CONTRACTOR TO EMPLOY A CERTIFIED ROOFING INSPECTOR MEETING THE

REQUIREMENTS OF THE INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL

BE REQUIRED TO BE CORRECTED PRIOR TO CLOSE OUT.

D. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE

RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.

PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT

WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY

MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.

E. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND FIRE

PROTECTION PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL

SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS

AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

F. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD

VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM

THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE

LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE

MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD

CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION

DOCUMENTS.

G. COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL TRADES PRIOR TO

INSTALLATION.

H. GALVANIC PROTECTION REQUIRED AT CONNECTIONS BETWEEN ALL

DISSIMILAR METALS.

I. ANY FLOOR, WALL, OR CEILING CUTTING THAT IS REQUIRED TO COMPLETE

THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND RETURN

TO MATCH EXISTING CONDITIONS AND FINISHES.

KEYNOTES

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

FOUNDATION

-2' - 0"

CORRIDOR

MA-122MA-122

ENGINEERING

CONTROL

CENTER

111111

A-501

D9

C1

A-301

6' -9

T

O P

O F

M A

S O

N R

Y

'-0

A-501

F7

A-551

B2

A-521

B6

10 11

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

E

ROOF LEVEL

26' - 6"

FOUNDATION

-2' - 0"

CT_FRAME

30' - 6"

CHILLER

ROOM

MA-109MA-109

ENGINEERING

CONTROL

CENTER

111111

A-511

C8

A-511

B7

A-551

B5

A-511

F8

A-551

B6

A-551

D6

9' -8

T O

P O

F S

C R

E E

N W

A

LL

'-0

A-512

F5

A-531

E4

'-6

4'

-0

3' -3

/2

1/ 2"

OFFICE

MA-203MA-203

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

SECOND_FLOOR_BEAM

10' - 11"

FOUNDATION

-2' - 0"

LOUNGE

116116

A-501

D9

'-0

A-501

F9

BEYOND

3' -0

T

Y P

3' -6

T

Y P

SLOPE

LEVEL_01

0' - 0"

LEVEL_02

12' - 0"

LEVEL_00

-12' - 0"

BASEMENT_TANK_BOT

-13' - 0"

BASEMENT_OFFSET_1/4"

-11' - 11 3/4"

SECOND_FLOOR_BEAM

10' - 11"

FOUNDATION

-2' - 0"

HOUSEKEEPING

AIDS

CLOSET

112112

A-501

D9

'-0

D1

A-501

BEYOND A-501

D4

7' -0

6' -9

LI

G

H T

F

IX

T U

R E

S 9'

-6

A5135

A5075

A-501

F95

SLOPE

C E

IL

IN

G 8'

-0

A-531

B8

BEYOND

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural and Subconsultants:

KEY PLAN

NOT FOR

CONSTRUCTION

A B

C

B

2058 S Dobson Rd., Suite 10, Mesa, AZ 85202

(480) 454-6408 www.unitedstr.com

B

IM

/5

-1

-1

O p ti m iz e

B

E n e rg y P la n t

/5

-1

-1

.4

.A

R C

H .r v t

/2 /2

:5

:2

P M

A-351

ARCHITECTURAL WALL SECTIONS

TRIPLE C THE A/E GROUP

2266 S. Dobson Road, Suite 200

Mesa, AZ 85202

(928) 499-3225

Mat Perkins

P2S ENGINEERING, INC.

5000 E. Spring Street

8th Floor

Long Beach, CA 90815-5218

Contact: Mikhail Fuks

UPGRADE ENERGY PLANT

EQUIPMENT INFRASTRUCTURE

(BLDG. 43 & 43A)

1501 SAN PEDRO SE ALBUQUERQUE, NM 87108

501-17-105

11/25/2019 M. PERKINS D. YOUNG

100% CONSTRUCTION

DOCUMENTS

1 EXISTING UTILITY TUNNEL TO REMAIN

2 NEW CONCRETE SIDEWALK, SEE CIVIL DRAWINGS

3 NEW EIFS WALL SYSTEM, SEE EXTERIOR ELEVATIONS FOR COLOR, R-9.5 MIN

ABOVE GRADE, R-7.5 BELOW

4 NEW R-15 MIN RIGID INSULATION ON AGGREGATE BASE COURSE WITH VAPOR

BARRIER

5 NEW CONCRETE FLOOR SLAB, SEE STRUCTURAL AND INTERIOR FINISHES, R-5

MIN

6 NEW BURNISHED CMU AT INTERIOR

7 NEW SUSPENDED CEILING SYSTEM

8 NEW EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS

9 NEW HOLLOW CORE CONCRETE DECK SYSTEM

10 NEW TPO ROOFING TO EXTEND UP WALL TO UNDER CAP, R-30 MIN

11 NEW CURB AT SCREEN WALL BRACE

12 NEW PREFINISHED PARAPET CAP, SEE EXTERIOR ELEVATIONS FOR COLOR

13 NEW ROOF TOP SCREEN WALL SYSTEM, BASIS OF DESIGN: STURDISTRUCT BY

ARCHITECTURAL LOUVERS

14 NEW SCUPPER

15 NEW CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS, PROVIDE R-15 MIN TO

24" BELOW GRADE

16 NEW PREFABRICATED PREFINISHED STEEL GRATE STAIR SYSTEM, TO MATCH

EXISTING

17 NEW PREFABRICATED STEEL GUARD AND HANDRAIL

18 NEW FOOTING AND NEW STEEL COLUMN STAIR SUPPORT, SEE STRUCTURAL

DRAWINGS

19 NEW TRANSLUCENT PANEL WINDOW SYSTEM WITH VISION PANEL OPENING, SEE

WINDOW TYPE ELEVATIONS, SHEET A-620

20 NEW WALL BASE, SEE INTERIOR FINISHES FOR ADDITIONAL INFORMATION

21 NEW ROOF PLATFORM AND SCREEN WALL. SEE A-401 FOR PLAN AND

STRUCTURAL DRAWINGS FOR LAYOUT.

22 NEW SCREEN WALL BRACING, SEE STRUCTURAL, PAINTED TO MATCH SCREEN

WALL

23 NEW COOLING TOWER AND ENCLOSURE ON ROOF

24 NEW COOLING TOWER PLATFORM, SEE ENLARGED PLAN, SHEET A-411

25 EXISTING STUCCO WALL SYSTEM TO BE REPAIRED

26 NEW TPO ROOFING TO EXTEND UP WALL TO UNDER SILL FLASHING, R-30 MIN

27 REMOVE EXISTING STUCCO FOR NEW ROOF SYSTEM, SEE DETAIL

28 NEW BURNISHED CMU WALL, SEE PLAN AND PARTITION TYPES FOR ADDITIONAL

INFORMATION

29 NEW FIRE RATED SHUTTER INTEGRATED WITH FIRE ALARM

30 NEW NON-RATED INTERIOR OBSERVATION WINDOW, SEE WINDOW TYPES

31 EXISTING CONCRETE FLOOR SLAB TO REMAIN

32 KALWALL PYRAMID, OR APPROVED EQUAL

33 WALL MOUNTED MONITORS, REFER TO A-401 FOR ADDITIONAL INFORMATION

1/2" = 1'-0" F1

WALL SECTION AT NEW CORRIDOR

1/2" = 1'-0"

F3

WALL SECTION AT NEW CONTROL ROOM

1/2" = 1'-0" E5

WALL SECTION AT SOUTH

1/2" = 1'-0" F7

WALL SECTION AT TUNNEL

Revisions: Date:

0 1'-0" 2'-0" 4'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

7/20/2022

MATHEW PERKINS

S

FCR

F

CR

4 4

C R

A-401C

C4

'-4

2'-7"

2' -7

1'-3"

CHEMICAL

TESTING

ROOM

110110

P8

CT020

C A

1M

C A

1M

CA041MCA041M

A-509

B1

S-1

P

A-509

B3

1'-10"

U0005

MR6: SOLID WASTE

MANAGEMENT - ONGOING

PROVIDE STORAGE FOR

RECYCLABLES OF GLASS &

PLASTIC

C

4.13 HCS PROGRAM

4.13.1 MSDSRWS

RWS

CS040

P1965 F2300

3.1 FACILITIES FOR

STORING & HANDLING

RECYCLABLE MATERIALS

3.1.2.3 GLASS

3.1.2.5 PLASTIC

R4000

A-401

D6

HOUSEKEEPING

AIDS

CLOSET

112112

JANC1

9'-0"

6' -0

F0500 F0505

A5077 P2000

A5107A5075

P4700

WFT-6

A5135

U0001

F2300

4.13 HCS PROGRAM

4.13.1 MSDS

4.5 WASTE WATER EFFLUENTS

4.5.1 PROTECT FLOOR DRAINS

4.14 HEALTH & SAFETY &

MANAGEMENT OF

HAZARDOUS PRODUCT

4.14.1 CHEMICAL IN SECURE

LOCATIONS W/ VENTILATION

SEE SHEET AC101

D

F2017 M3073

MR-1:

COLLECTION FOR HAZARDOUS WASTE,

BATTERIES AND LAMPS

MR-6:

SOLID WASTE

MANAGEMENT-

ONGOING PROVIDE

STORAGE FOR

RECYCLABLES

EQ-10:

STORAGE CABINET FOR

GREEN CLEANING CHEMICALS

EQ-11: GREEN

CLEANING -

EQUIPMENT

EQ-10 CREDIT:

GREEN CLEANING-

PRODUCTS AND

MATERIALS

U0003

U0004

A5082

2.2 WATER CONSERVING

FEATURES 2.2.1.9 HAND

SANITIZERS/RUBS

3.1 FACILITIES FOR STORING &

HANDLING RECYCLABLE MATERIALS

3.1.2.9 ELECTRONIC AND BATTERIES

P8

P

A-401

E2

F0275

E0117M

F0275

E0117M

E0117M

F0275

M2055M2055

323232

E6

E

E

RWS

A-509

B5

5.8 LIGHTING

FEATURES

5.8.2 CONTROLLABLE

SHADING DEVICE

P

P

P8

GREEN GLOBES

1.2 LIGHTING

1.2.1.6 TASK LIGHTING

LEED EQ-7

INTERIOR LIGHTING

M2055M2055

F0225

F0225

F0795M

F0225

U0005

MR-6: SOLID WASTE

MANAGEMENT-ONGOING

PROVIDE STORAGE FOR

RECYCLABLES

F2000

U0002

U0002 U0002

ENGINEERING

CONTROL

CENTER

111111

'-0

22'-0 3/8"

3.1 FACILITIES FOR STORING &

HANDLING RECYCLABLE MATERIALS

3.1.2.3 GLASS

3.1.2.5 PLASTIC

P8

P8

1' -8

/4

U0006U0006

E0117M

U0006

U0006

2' -6

1'

-6

2' -1

0"

9' -0

8' -0

C05F0

C05F0

CA041M

CA041M

CT020

2'-9" 3'-4" 2'-9" 3'-4"

35 35

OPEN OPEN

PL-1 RB-1

C04F0M

CA041M

D5

A-541

B9

A-541

PL-1

PL-1

PL-1

S-1

PL-1

1'-3"

6"

10 10

RWS RWS

E7

IN601

TYP.

CA041M

C04P0M

2'-9" 3'-0"

2' -6

1'

-6

2' -1

0"

6' -1

0"

9' -0

CT020

3'-0"3'-0"

9'-2"RB-1

PL-1

S-1

PL-1

D5

A-541

B7

A-541

B9

A-541

4"

P1965

1'-10"

10"

8' -0

2'-0"

" 2'

-0 " 3'

-6

2' -1

0"3' -6

W F

T -6

4' -1

P4700 A5075

A5107

P2000

A5077

P2451M

A5135

6' -0

4' -4

1'-3"

U0001

RB-1

WFT-6

3'-0" 1'-9" 11" 1'-11"

1'-0"

EQ-10:

STORAGE CABINET FOR

GREEN CLEANING

CHEMICALS

EQ-11: GREEN

CLEANING -

EQUIPMENT

U0003

U0004

A5082

2.2 WATER CONSERVING

FEATURES 2.2.1.9 HAND

SANITIZERS/RUBS

9' -0

7' -4

E0117ME0117MF0275 F0275

A1015

SKYLIGHT

F0275RB-1

5 6

U0007 U0007 U0007 U0007U0007

GREEN GLOBES

1.2 LIGHTING

1.2.1.6 TASK LIGHTING

LEED EQ-7

INTERIOR

LIGHTING,TYP.

U0002

U0002

U0002

A1015

2'-0 3/8"4'-0"4'-0"4'-0"4'-0"4'-0"

GENERAL NOTES

A. CONTRACTOR TO AVOID ALL PLANT SHUT DOWNS.

B. CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY UTILITIES.

C. CONTRACTOR TO COORDINATE WITH RECENT ROOF INSTALLATION

WARRANTY REQUIREMENTS TO ENSURE NO VIOLATIONS OCCUR.

CONTRACTOR TO EMPLOY A CERTIFIED ROOFING INSPECTOR MEETING THE

REQUIREMENTS OF THE INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL

BE REQUIRED TO BE CORRECTED PRIOR TO CLOSE OUT.

D. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE

RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.

PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT

WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY

MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.

E. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND FIRE

PROTECTION PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL

SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS

AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

F. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD

VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM

THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE

LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE

MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD

CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION

DOCUMENTS.

G. COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL TRADES PRIOR TO

INSTALLATION.

H. GALVANIC PROTECTION REQUIRED AT CONNECTIONS BETWEEN ALL

DISSIMILAR METALS.

I. ANY FLOOR, WALL, OR CEILING CUTTING THAT IS REQUIRED TO COMPLETE

THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND RETURN

TO MATCH EXISTING CONDITIONS AND FINISHES.

KEYNOTES

V V ITEM - VA SUPPLIED & INSTALLED

V C ITEM - VA SUPPLIED &

CONTRACTOR INSTALLED

C C ITEM - CONTRACTOR SUPPLIED &

INSTALLED

FURNITURE, FIXTURE, & EQUIPMENT

INDICATOR

A1000

EQUIPMENT / FURNITURE LEGEND

32 32 32

8' -0

"9' -0

M2055

SKYLIGHT

6' -0

2'-0"4'-0"4'-0"4'-0"

E Q

E Q

E

Q

RWS-1 RWS-1

RB-1

5.8 LIGHTING FEATURES

5.8.2 CONTROLLABLE

SHADING DEVICE

M2055 M2055 M2055 U0005 MR-6: SOLID

WASTE

MANAGEMENT-

ONGOING

PROVIDE

STORAGE FOR

RECYCLABLES

3.1 FACILITIES FOR STORING &

HANDLING RECYCLABLE MATERIALS

3.1.2.3 GLASS

3.1.2.5 PLASTIC

F0225

F0795M E0117M5

RB-1

A-531

E4

U0002

A1015

F0275F0225

F0225

M2055

U0005

9' -0

6' -9

6' -6

U0006

M2055

E0117M

E0117M

F0275

RB-1

A-531

E4

GREEN GLOBES

1.2 LIGHTING

1.2.1.6 TASK

LIGHTING

LEED EQ-7

INTERIOR

LIGHTING

U0002 U0002 A1015

F2000

9' -0

6' -2

E7

IN601 TYP.

PATTERN OR COLOR CHANGE

MATERIAL FLOOR CHANGE (REFER TO IN601

FOR TRANSITION DETAILS)

DIRECTION OF FINISH

INTERIOR FINISH SYMBOLS

P-_ PAINT COLOR / WALL FINISHES

EXTENT OF WALL FINISH TYPE

CORNER GUARD LOCATIONCG

GRAIN

REFER TO SHEET IN601 FOR ROOM FINISH SCHEDULE & FINISH LEGEND

FINISHES LISTED ARE THE OVERALL FINISHES SPECIFIED FOR EACH SPACE.

REFER TO PLANS FOR ADDITIONAL WALL FINISHES REQUIRED FOR EACH SPACE.

RB-1

F0500

A5135

F0505

P4700

EQ-11: GREEN

CLEANING - EQUIPMENT

WFT-6 7

U0004

W F

T -6

4' -1

2' -0

6' -0

8' -0

E7

IN601

6"

4'-1"

U0005

F2300 C04P0M

CT020

CS040

P1965

RB-1

S-1

PL-1

4.13 HCS PROGRAM

4.13.1 MSDS

MR6: SOLID WASTE

MANAGEMENT -

ONGOING

6' -1

0"

9' -0

2' -1

0"

3.1 FACILITIES FOR STORING &

HANDLING RECYCLABLE MATERIALS

3.1.2.3 GLASS

3.1.2.5 PLASTIC

R4000

E7

IN601

TYP.

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural and Subconsultants:

KEY PLAN

NOT FOR

CONSTRUCTION

B

C

B

2058 S Dobson Rd., Suite 10, Mesa, AZ 85202

(480) 454-6408 www.unitedstr.com

B

IM

/5

-1

-1

O p ti m iz e

B

E n e rg y P la n t

/5

-1

-1

.4

.A

R C

H .r v t

/2 /2

:5

:3

P M

A-401

ARCHITECTURAL ENLARGED VIEWS

TRIPLE C THE A/E GROUP

2266 S. Dobson Road, Suite 200

Mesa, AZ 85202

(928) 499-3225

Mat Perkins

P2S ENGINEERING, INC.

5000 E. Spring Street

8th Floor

Long Beach, CA 90815-5218

Contact: Mikhail Fuks

UPGRADE ENERGY PLANT

EQUIPMENT INFRASTRUCTURE

(BLDG. 43 & 43A)

1501 SAN PEDRO SE ALBUQUERQUE, NM 87108

501-17-105

11/25/2019 M. PERKINS K.

MCDERMOTT

100% CONSTRUCTION

DOCUMENTS

1/4" = 1'-0" C8

CHEMICAL TESTING ROOM - 110

1/4" = 1'-0" D8

HAC - 112

1/4" = 1'-0" E8

ENGINEERING CONTROL CENTER -

1/4" = 1'-0" C2

CHEMICAL TESTING 110 - NORTH

ELEVATION

1/4" = 1'-0" C4

CHEMICAL TESTING 110 - EAST

ELEVATION

1/4" = 1'-0" D6

HAC - WEST ELEVATION

1/4" = 1'-0" E2

ENGINEERING CONTROL CENTER 111

- WEST ELEVATION

INTERIOR FINISH ABBREVIATIONS

ABBREVIATION FINISH TYPE

AT ACOUSTICAL CEILING TILE

C SEALED CONCRETE

CG CORNER GUARD

CMU CONCRETE MASONRY UNIT BLOCK

EPY EPOXY FLOORING

P PAINT

PL PLASTIC LAMINATE

PT PORCELAIN TILE

RB RESILIENT BASE

RWC RIGID WALL COVERING

RWS WINDOW SHADES

S SOLID SURFACE

SS STAINLESS STEEL

TR TILE TRIM

WD PLYWOOD

WFT WALL FINISH TYPE

JSN Schedule

JSN Nomenclature Furn. By/

Installed By R4000 Ice Maker, Freestanding, SS VV

R7250M Refrigerator/Freezer, 20 Cubic Feet, SS VV

U0001 Cabinet, W/H, 2 Shelf, 2 DO, non-sloping top, w/ trays for chemical spillage CC

U0002 Task Light, Freestanding VV

U0003 Power Washer VV

U0004 Chemical Cleaning Solution Dispenser VV

U0005 Container, Combination, Trash/Recycling, Small VV

U0006 Monitor Arm, Quad monitors CC

U0007 Single Wall Mount Monitor Arm CC

X1060M Cabinet, base, 1 door CC

JSN Schedule

JSN Nomenclature Furn. By/

Installed By F2017M Waste Receptacle, SS, 12 GAL VV

F2300 Rack, Information, Wall Mounted VV

F3065 Whiteboard/Bulletin Board, Combination VC

F3200 Clock, Battery, 12in Dia CC

K1552 Brewer, Coffee, Auto, Elect, 3 Burner, Front/Back VV

K2515 Dishwasher, Household CC

K4500M Stove, Household, 4 Burner, w/Oven, Electric, SS VC

K4665 Oven, Microwave, Consumer, SS CC

M2055 Shelving, Storage, Wire, CRS, w/Adjustable Shelves VV

M3073 Basket, Infectious Waste, Step-on VV

P1965 Eyewash, Eye-Face, Sink Mounted, Hands-free CC

P2000 Eyewash, Wall Mounted, Hands-Free CC

P2100 Disposal, Garbage, 2 HP Motor CC

P2451M Valve, Mixing, Thermostatic, serving double eyewash stations CC

P4700 Sink, Mop, Molded Stone CC

P5210M Shower, Single, Hand-Held CC

R2200M Fountain, Water, SS CC

JSN Schedule

JSN Nomenclature Furn. By/

Installed By C03P0 Cabinet, Sink, U/C/B, 2 Door CC

C04F0M Cabinet, U/C/B, 1 Shelf, 2 Half DR, 2 DO CC

C04P0M Cabinet, Sink, U/C/B, 2 Door CC

C05F0 Cabinet, U/C/B, 1 Shelf, 2 Half DR, 2 DO CC

CA041M Cabinet, W/H, 2 Shelf, 2 DO, non-sloping top CC

CS040 Sink, SS, Single Compartment CC

CS230 Sink, SS, Double Compartment CC

CT020 Countertop, Solid Surface CC

E0117M Workstation, Straight, Free Standing sit to stand CC

F0225 Chair, Stacking VV

F0275 Chair, Swivel, High Back VV

F0500 Cart, Janitor's VV

F0505 Bucket, Mop, With Wringer, 26 Quart VV

F0795M Table, Dining VV

F2000 Basket, Wastepaper, Fire Resistant VV

F2015 Basket, Wastepaper, SS, 2 Swinging Doors VV

F2017 Waste Receptacle, 24 Gal VV

JSN Schedule

JSN Nomenclature Furn. By/

Installed By A1012 Telephone, Wall Mounted, 1 Line VV

A1015 Telephone, Desk, Multiple Line 12 x 12 VV

A1035 Locker, Single Tier CC

A1067 Mirror, Float Glass, ADA Accessible CC

A1080 Mirror, Posture, Wall Mtd 28" x 6" CC

A1145 Shelving, Mobile, Manual CC

A5075 Dispenser, Soap, Disposable CC

A5077 Dispenser, Hand Sanitizer, Hands-Free VC

A5082 Dispenser, Paper Towel, Sensor, Hands Free VC

A5090 Disposal, Sanitary Napkin, SS, Surface Mounted VC

A5107 Dispenser, Glove, Surgical/Examination, Wall Mntd CC

A5109M Corner Grab Bar, 1-1/4" Dia., SS, 2 Wall, W/C Accessible CC

A5135 Shelf, Utility W/ Mop/Broom Holders, SS, Surf Mntd CC

A5170 Rod, Shower Curtain, 1"Diameter, W/Curtain & Hooks CC

A5200 Dispenser, Toilet Tissue, SS, 2-Roll, Surface Mntd VC

A5215 Bracket, Television, Wall-Mounted, Tilt/Angle CC

C02D0 Cabinet, U/C/B,4 Drawer CC

NOTE:

1. JSN NUMBERS THAT END WITH AN "M" SUFFIX INDICATE THAT THE ITEM IS A

MODIFIED VERSION OF THE VA'S EQUIPMENT LIST

2. JSN NUMBERS THAT START WITH A "U" PREFIX INDICATE THAT THE ITEM

DOES NOT HAVE A NUMBER IN THE VA EQUIPMENT LIST

1/4" = 1'-0" E6

ENGINEERING CONTROL CENTER 111

- EAST ELEVATION

1/4" = 1'-0" E4

ENGINEERING CONTROL CENTER 111

- SOUTH ELEVATION

1/4" = 1'-0" E1

ENGINEERING CONTROL CENTER 111

- NORTH ELEVATION

1 SLOPE FLOOR TO DRAIN, INSTALL PROTECTION FOR FLOOR DRAINS WHERE

CHEMICALS ARE USED; REFER TO PLUMBING SHEETS FOR ADDITIONAL

INFORMATION

2 TRENCH DRAIN, SLOPE FLOOR TO DRAIN AT CORNERS. REFER TO PLUMBING

SHEETS FOR ADDITIONAL INFORMATION

3 OCCUPANCY SENSOR, REFER TO ELECTRICAL SHEETS FOR ADDITIONAL

INFORMATION

4 APPROX 50 LINEAR FEET OF STORAGE FOR OWNER MANUALS

5 OPEN SHELVING BELOW PENINSULA

6 SIT TO STAND WORK STATION, WITH GROMMETS OR INTEGRAL CABLE

MANAGEMENT

7 EXTENT OF WALL PROTECTION, REFER TO INTERIOR FINISH SHEETS FOR

ADDITIONAL INFORMATION

8 NEW RECESSED FLOOR SLAB IN THIS SPACE, REFER TO STRUCTURAL FOR

ADDITIONAL INFORMATION

9 INDIRECT LIGHT COVE, 6" HOLD BACK OF ACOUSTICAL TILE FOR INDIRECT COVE

LIGHT TRIM, SEE SHEET A-531

10 UNDERCABINET TASK LIGHTING, REFER TO D5/A-541

11 ELECTRICAL EQUIPMENT. REFER TO ELECTRICAL SHEETS FOR ADDITIONAL

INFORMATION.

12 NEW BOX AND SURFACE MOUNTED MIXING VALVE

13 WALL MOUNTED MONITORS ARE PROVIDED BY VA, TYP.

1/4" = 1'-0" D4

HAC - NORTH ELEVATION

1/4" = 1'-0" C6

CHEMICAL TESTING 110 - SOUTH

ELEVATION

Revisions: Date:

0 2'-0" 4'-0" 8'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

7/20/2022

MATHEW PERKINS

O

F

S

W

C R

CR

2' -1

0"4 1/

2"

1' -3

"1 '-4

/2

1'

-4

7' -2

2'-9"

2'-9"

CT020

K4665

C02D0

K4500M R7250M

S-1

PL-1

PL-1

RB-1

D3

A-541

D9

A-541

B5

A-541

B3

A-541

X1060M PL-1

3'-0"

CA041M

CA041M

1'-3" 1'-3" 3"

CA041M

CG-1

CG-1

FILLER

PL-1

A-402B

A-402

B6

8'-0"

STORAGE

MA-121MA-121

'-6

4'-0" MIN.

4'-4 3/4"

1'-4 3/4"

5'-10"

6' -0

8'-0"

A1145

MR-6: SOLID WASTE

MANAGEMENT - ONGOING

U0005

A-509

D3

A-509

D5

WL-6

GENERAL NOTES

A. CONTRACTOR TO AVOID ALL PLANT SHUT DOWNS.

B. CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY UTILITIES.

C. CONTRACTOR TO COORDINATE WITH RECENT ROOF INSTALLATION

WARRANTY REQUIREMENTS TO ENSURE NO VIOLATIONS OCCUR.

CONTRACTOR TO EMPLOY A CERTIFIED ROOFING INSPECTOR MEETING THE

REQUIREMENTS OF THE INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL

BE REQUIRED TO BE CORRECTED PRIOR TO CLOSE OUT.

D. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE

RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.

PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT

WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY

MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.

E. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND FIRE

PROTECTION PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL

SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS

AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

F. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD

VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM

THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE

LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE

MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD

CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION

DOCUMENTS.

G. COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL TRADES PRIOR TO

INSTALLATION.

H. GALVANIC PROTECTION REQUIRED AT CONNECTIONS BETWEEN ALL

DISSIMILAR METALS.

I. ANY FLOOR, WALL, OR CEILING CUTTING THAT IS REQUIRED TO COMPLETE

THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND RETURN

TO MATCH EXISTING CONDITIONS AND FINISHES.

KEYNOTES

V V ITEM - VA SUPPLIED & INSTALLED

V C ITEM - VA SUPPLIED &

CONTRACTOR INSTALLED

C C ITEM - CONTRACTOR SUPPLIED &

INSTALLED

FURNITURE, FIXTURE, & EQUIPMENT

INDICATOR

A1000

EQUIPMENT / FURNITURE LEGEND

LOUNGE

116116

SL001

A-402D

12'-9 1/4"

A-402

E4

E

F2015

K1552

R7250M

F3065

A1080

WFT-4

D6

1' -1

1"

3B

1'-2"

A-509

B9

K4500M

A-402 D

F0795MF0225

F0225 F0225

F0225

F0795M

F0225

F0225

F0225

CT020

K2515

CA041M

CA041M

2.2 WATER

CONSERVING

FEATURES

2.2.1.11 WATER

SAVING DISWHASER

U0005

CT020

K4665

CA041M

MR-6: SOLID WASTE

MANAGEMENT - ONGOING

STORAGE FOR RECYCLABLE

MATERIALS

A5077

2'-1"

RWS-1

RWS-1

RWS-1

A5082

A5075

CG-1

A4

L4

A

LI

G N

ALIGN

D

VESTIBULE

103103

103C

W F

T -3

5' -0

WFT-3

4'-4 1/2"

6'-3 3/8"

W F

T -2

6' -4

/8

SLOPE

GG 2.2.1.7

P5210M

A5170

A5077

6"

CORRIDOR

MA-133

66 SF

SHOWER/CHANGE

66 SF

2.2 WATER CONSERVING

FEATURES 2.2.1.9 HAND

SANITIZERS/RUBS

3.1 FACILITIES FOR STORING

& HANDLING RECYCLABLE

MATERIALS

3.1.2.1 PAPER PRODUCTS

3.1.2.2 CARDBOARD

3.1.2.3 GLASS

3.1.2.4 METAL

3.1.2.5 PLASTIC

A4

A

A

E4

L4

A

SS-1

/-2

'-9

/8

5' -3

/2

8' -0

/8

4'-1 1/8"

CS230

B1

IN601

WFT-2

6'-9 1/4"

F3200

6' -0

CORRIDOR

BEYOND

RB-1

CA041M

CA041M

K1552 S-1

2' -1

0" 2'

-4

2' -0

2'-0" 2'-10"

8'-0 5/8"

D9

A-541

B1

A-541

K2515

A5082 A1012

3' -6

CT020

PL-1

A5075

1'-10 1/2"

PL-1

2.2 WATER CONSERVING FEATURES

2.2.1.11 WATER SAVING DISWHASER

2'-10 1/2"

3'-2"

C03P0

2'-1 1/2"

E7

IN601

8' -0

8'-0"

'-5

/2

EPY-1

A1145

U0005

E4

A-301

E4

A-301

'-5

/2

8' -0

11'-6"

EPY-1

E3

IN601

TYP.

C

CG-1CG-1

8' -0

W F

T -5

4' -0

EPY-1

4' -4

4"

E3

IN601

TYP.

A1035

6' -4

TYP

1'-0".

PATTERN OR COLOR CHANGE

MATERIAL FLOOR CHANGE (REFER TO IN601

FOR TRANSITION DETAILS)

DIRECTION OF FINISH

INTERIOR FINISH SYMBOLS

P-_ PAINT COLOR / WALL FINISHES

EXTENT OF WALL FINISH TYPE

CORNER GUARD LOCATIONCG

GRAIN

REFER TO SHEET IN601 FOR ROOM FINISH SCHEDULE & FINISH LEGEND

FINISHES LISTED ARE THE OVERALL FINISHES SPECIFIED FOR EACH SPACE.

REFER TO PLANS FOR ADDITIONAL WALL FINISHES REQUIRED FOR EACH SPACE.

1' -6

"2' -1

1"

3'-0" 1'-0"

2'-9"2 1/2"

4' -0

W F

T -3

8' -0

P5210M

W F

T -2

5' -0

WFT-3

5'-0"

A5170

1' -6

"2' -1

1"

3' -4

4" 1'

-6

1'-6"10"

P5210M

2'-6"

W F

T -3

8' -0

A5170

4'-0" W

F T

-2 3'

-6

WFT-2

WFT-3

TR-1

6' -0

WFT-3

4'-4 1/2"

WFT-2

6'-8"

E5

IN601

TYP.

TOILET,

STAFF

114114

TNPG1

A-402

B3

A

6' -7

/8

8'-4"

A5090

A5200

A5082

A5075 A1067

A5109M

WFT-2

B

1'-6"

F2017M

A5077

10"

GG 2.2.1.3

GG 2.2.1.4

2.2 WATER CONSERVING

FEATURES

2.2.1.9 HAND

SANITIZERS/RUBS

E

P8

A4

A

B1

IN601

2'-0"

A5082

A1067

A5075

F2017M

WFT-2

E5

IN601

TYPW

F

T -2

3' -6

8' -0

3' -4

3' -6

2' -1

0"

2'-0"

1' -6

2' -4

2' -9

W F

T -2

3' -6

2' -1

C L

A5090

A5200

A5109M

A5075

A5082

F2017M

A1067

2'-0" 1'-0" 6"

1'-6"2'-0"

WFT-2

1' -6

2' -1

2' -4

2' -9

W F

T -2

3' -6

8' -0

1'-0"

3'-4"

A5090

A5200

A5109M

1'-0" 3'-6"

WFT-2

2'-0"

2' -1

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural and Subconsultants:

KEY PLAN

NOT FOR

CONSTRUCTION

A

C

2058 S Dobson Rd., Suite 10, Mesa, AZ 85202

(480) 454-6408 www.unitedstr.com

B

IM

/5

-1

-1

O p ti m iz e

B

E n e rg y P la n t

/5

-1

-1

.4

.A

R C

H .r v t

/2 /2

:5

:4

P M

A-402

ARCHITECTURAL ENLARGED VIEWS

TRIPLE C THE A/E GROUP

2266 S. Dobson Road, Suite 200

Mesa, AZ 85202

(928) 499-3225

Mat Perkins

P2S ENGINEERING, INC.

5000 E. Spring Street

8th Floor

Long Beach, CA 90815-5218

Contact: Mikhail Fuks

UPGRADE ENERGY PLANT

EQUIPMENT INFRASTRUCTURE

(BLDG. 43 & 43A)

1501 SAN PEDRO SE ALBUQUERQUE, NM 87108

501-17-105

11/25/2019 M. PERKINS N.

BLANCHARD

100% CONSTRUCTION

DOCUMENTS

1/4" = 1'-0" D6

LOUNGE 116 - WEST ELEVATION

1/4" = 1'-0" B7

STORAGE - MA-121

INTERIOR FINISH ABBREVIATIONS

ABBREVIATION FINISH TYPE

AT ACOUSTICAL CEILING TILE

C SEALED CONCRETE

CG CORNER GUARD

CMU CONCRETE MASONRY UNIT BLOCK

EPY EPOXY FLOORING

P PAINT

PL PLASTIC LAMINATE

PT PORCELAIN TILE

RB RESILIENT BASE

RWC RIGID WALL COVERING

RWS WINDOW SHADES

S SOLID SURFACE

SS STAINLESS STEEL

TR TILE TRIM

WD PLYWOOD

WFT WALL FINISH TYPE

JSN Schedule

JSN Nomenclature Furn. By/

Installed By R4000 Ice Maker, Freestanding, SS VV

R7250M Refrigerator/Freezer, 20 Cubic Feet, SS VV

U0001 Cabinet, W/H, 2 Shelf, 2 DO, non-sloping top, w/ trays for chemical spillage CC

U0002 Task Light, Freestanding VV

U0003 Power Washer VV

U0004 Chemical Cleaning Solution Dispenser VV

U0005 Container, Combination, Trash/Recycling, Small VV

U0006 Monitor Arm, Quad monitors CC

U0007 Single Wall Mount Monitor Arm CC

X1060M Cabinet, base, 1 door CC

JSN Schedule

JSN Nomenclature Furn. By/

Installed By F2017M Waste Receptacle, SS, 12 GAL VV

F2300 Rack, Information, Wall Mounted VV

F3065 Whiteboard/Bulletin Board, Combination VC

F3200 Clock, Battery, 12in Dia CC

K1552 Brewer, Coffee, Auto, Elect, 3 Burner, Front/Back VV

K2515 Dishwasher, Household CC

K4500M Stove, Household, 4 Burner, w/Oven, Electric, SS VC

K4665 Oven, Microwave, Consumer, SS CC

M2055 Shelving, Storage, Wire, CRS, w/Adjustable Shelves VV

M3073 Basket, Infectious Waste, Step-on VV

P1965 Eyewash, Eye-Face, Sink Mounted, Hands-free CC

P2000 Eyewash, Wall Mounted, Hands-Free CC

P2100 Disposal, Garbage, 2 HP Motor CC

P2451M Valve, Mixing, Thermostatic, serving double eyewash stations CC

P4700 Sink, Mop, Molded Stone CC

P5210M Shower, Single, Hand-Held CC

R2200M Fountain, Water, SS CC

JSN Schedule

JSN Nomenclature Furn. By/

Installed By C03P0 Cabinet, Sink, U/C/B, 2 Door CC

C04F0M Cabinet, U/C/B, 1 Shelf, 2 Half DR, 2 DO CC

C04P0M Cabinet, Sink, U/C/B, 2 Door CC

C05F0 Cabinet, U/C/B, 1 Shelf, 2 Half DR, 2 DO CC

CA041M Cabinet, W/H, 2 Shelf, 2 DO, non-sloping top CC

CS040 Sink, SS, Single Compartment CC

CS230 Sink, SS, Double Compartment CC

CT020 Countertop, Solid Surface CC

E0117M Workstation, Straight, Free Standing sit to stand CC

F0225 Chair, Stacking VV

F0275 Chair, Swivel, High Back VV

F0500 Cart, Janitor's VV

F0505 Bucket, Mop, With Wringer, 26 Quart VV

F0795M Table, Dining VV

F2000 Basket, Wastepaper, Fire Resistant VV

F2015 Basket, Wastepaper, SS, 2 Swinging Doors VV

F2017 Waste Receptacle, 24 Gal VV

JSN Schedule

JSN Nomenclature Furn. By/

Installed By A1012 Telephone, Wall Mounted, 1 Line VV

A1015 Telephone, Desk, Multiple Line 12 x 12 VV

A1035 Locker, Single Tier CC

A1067 Mirror, Float Glass, ADA Accessible CC

A1080 Mirror, Posture, Wall Mtd 28" x 6" CC

A1145 Shelving, Mobile, Manual CC

A5075 Dispenser, Soap, Disposable CC

A5077 Dispenser, Hand Sanitizer, Hands-Free VC

A5082 Dispenser, Paper Towel, Sensor, Hands Free VC

A5090 Disposal, Sanitary Napkin, SS, Surface Mounted VC

A5107 Dispenser, Glove, Surgical/Examination, Wall Mntd CC

A5109M Corner Grab Bar, 1-1/4" Dia., SS, 2 Wall, W/C Accessible CC

A5135 Shelf, Utility W/ Mop/Broom Holders, SS, Surf Mntd CC

A5170 Rod, Shower Curtain, 1"Diameter, W/Curtain & Hooks CC

A5200 Dispenser, Toilet Tissue, SS, 2-Roll, Surface Mntd VC

A5215 Bracket, Television, Wall-Mounted, Tilt/Angle CC

C02D0 Cabinet, U/C/B,4 Drawer CC

NOTE:

1. JSN NUMBERS THAT END WITH AN "M" SUFFIX INDICATE THAT

THE ITEM IS A MODIFIED VERSION OF THE VA'S EQUIPMENT LIST

2. JSN NUMBERS THAT START WITH A "U" PREFIX INDICATE THAT

THE ITEM DOES NOT HAVE A NUMBER IN THE VA EQUIPMENT

LIST

1/4" = 1'-0" E7

LOUNGE/ SHOWER/ VESTIBULE

1/4" = 1'-0" D4

LOUNGE 116 - NORTH ELEVATION

1/4" = 1'-0" B6

STORAGE - EAST ELEVATION

1/4" = 1'-0"

B4

STORAGE - NORTH ELEVATION

1 GARBAGE DISPOSAL, SEE PLUMBING AND ELECTRICAL FOR ADDITIONAL

INFORMATION

2 NEW STOVE HOOD WITH INTEGRAL BACK SPLASH AND SIDE SPLASH REFER TO

MECHANICAL FOR ADDITIONAL INFORMATION

3 HIGH DENSITY STORAGE UNIT, MECHANICAL ASSIT MOBILE SYSTEM

4 HIGH DENSITY STORAGE TRACK SYSTEM MOUNTED ON EXISTING FLOOR

5 SINGLE SIDED SHELF DEPTH

6 DOUBLE SIDED SHELF DEPTH

7 APPROX. 460 LINEAR FEET OF SHELF STORAGE, REFERENCE JSN ID A1445

8 HIGH DENSITY STORAGE UNIT HIGH PRESSURE LAMINATE END PANELS, TYPICAL

9 CARD HOLDERS FOR LABELING, TYPICAL

10 CENTER STOP AT EACH DOUBLE SIDED CARRIAGE, TYPICAL

11 GYPSUM WALLBOARD SOFFIT, REFER TO CEILING PLANS

12 ELECTRIC WATER COOLER, REFER TO G-050 FOR ADDITIONAL INFORMATION

13 NEW METAL PANEL WALL SYSTEM TO MATCH EXISTING INSULATED METAL PANEL

AT REMOVED LOUVER

14 EXISTING STEEL CHANNEL

15 MILLWORK FILLER PIECE

16 ADA COMPLIANT P-TRAP COVER, REFER TO PLUMBING SHEETS FOR ADDITIONAL

INFORMATION

17 EXTENT OF WALL TILE; TILE BEHIND WALL MOUNTED FIXTURES

18 NEW WALL MOUNTED TYPE C - 10 LB FIRE EXTINGUISHER

19 NEW RECESSED FLOOR SLAB IN THIS SPACE, REFER TO STRUCTURAL FOR

ADDITIONAL INFORMATION

20 SLOPE FLOOR TO DRAIN, INSTALL PROTECTION FOR FLOOR DRAINS WHERE

CHEMICALS ARE USED; REFER TO PLUMBING SHEETS FOR ADDITIONAL

INFORMATION

21 TRENCH DRAIN, SLOPE FLOOR TO DRAIN AT CORNERS. REFER TO PLUMBING

SHEETS FOR ADDITIONAL INFORMATION

22 NEW RECESSED FLOOR SLAB IN THIS SPACE, REFER TO STRUCTURAL FOR

ADDITIONAL INFORMATION

23 OWNER'S EXISTING ELECTRIC STOVE

24 NEW MICROWAVE, CONTRACTOR PURCHASED AND INSTALLED

25 NEW DISHWASHER, CONTRACTOR PURCHASED AND INSTALLED

26 NEW LOCKERS, CONTRACTOR PURCHASED AND INSTALLED

1/4" = 1'-0" D3

VESTIBULE - SOUTH ELEVATION

1/4" = 1'-0" E6

SHOWER/CHANGE 115 - NORTH

ELEVATION

1/4" = 1'-0" E4

SHOWER/CHANGE 115 - WEST

ELEVATION

1/4" = 1'-0" A3

TOILET - 114

1/4" = 1'-0" B1

TOILET 114- SOUTH ELEVATION

1/4" = 1'-0"

B3

TOILET 114 - WEST ELEVATION

1/4" = 1'-0" A1

TOILET 114 - NORTH ELEVATION

Revisions: Date:

0 2'-0" 4'-0" 8'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

0 2'-0" 4'-0" 8'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

7/20/2022

MATHEW PERKINS

B. CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY UTILITIES.

C. CONTRACTOR TO COORDINATE WITH RECENT ROOF INSTALLATION

WARRANTY REQUIREMENTS TO ENSURE NO VIOLATIONS OCCUR.

CONTRACTOR TO EMPLOY A CERTIFIED ROOFING INSPECTOR MEETING THE

REQUIREMENTS OF THE INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL

BE REQUIRED TO BE CORRECTED PRIOR TO CLOSE OUT.

D. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE

RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.

PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT

WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY

MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.

E. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND FIRE

PROTECTION PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL

SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS

AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

F. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD

VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM

THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE

LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE

MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD

CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION

DOCUMENTS.

G. COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL TRADES PRIOR TO

INSTALLATION.

H. GALVANIC PROTECTION REQUIRED AT CONNECTIONS BETWEEN ALL

DISSIMILAR METALS.

I. ANY FLOOR, WALL, OR CEILING CUTTING THAT IS REQUIRED TO COMPLETE

THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND RETURN

TO MATCH EXISTING CONDITIONS AND FINISHES.

KEYNOTES

ROOF LEVEL

26' - 6"

CT_FRAME

30' - 6"

1'-0"

(6 TREADS AT 11")

5'-6"

6' -8

(7

R

IS

E R

S A

T

.1

3'

-0

/8

T Y

P

1/ 8"

H A

N D

R A

IL

2'

-9

/8

A-511

D4

ROOF LEVEL

26' - 6"

CT_FRAME

30' - 6"

B7

A-511

3' -3

/2

1/

2"

'-3

/2

'-0

VERIFY

6'-0"6'-6 1/2"6'-5 5/8"4'-6"4'-6"3'-6 1/2"

VERIFY

33'-0"

L39

D4

A-501

ROOF LEVEL

26' - 6"

CT_FRAME

30' - 6"

B7

A-511

23'-0"

3' -3

/2

'-0

'-3

/2

1/ 2"

L39

6' -8

8" 5'-0" 5'-0" 5'-0" 6'-8" 8"

3'-0" 2'-4 1/2"

F7

A-411

D4

A-501

ROOF LEVEL

26' - 6"

CT_FRAME

30' - 6"

B7

A-511

23'-7"

3' -3

/2

'-0

L39

1'-3" 6'-8" 5'-0" 5'-0" 5'-0" 8"

D4

A-501

LEVEL_02

12' - 0"

6' -0

" 7' -0

4'-0" 6'-0" 6'-0"

L115

D4

A-501

16'-0"

LEVEL_02

12' - 0"

7' -0

6' -0

8'-0"8'-0"8'-0"8'-0"

32'-0"

L115

LEVEL_02

12' - 0"

4'-0"

6' -0

"7' -0

L115

NEW PREFABRICATED

ROOFTOP SCREEN WALL

SYSTEM, BASIS OF DESIGN:

ARCHITECTURAL LOUVERS,

STURDISTRUCT WITH V4JS

EXTRUDED ALUMINUM

LOUVERED EQUIPMENT

SCREEN

4 5 6

C4

A-301

C4

A-301

F7

A-411

A-411

E1

A-411

B1

F5

A-512

D4

A-511

B4

A-512

9 3/4" 6'-0" 6'-6 1/2" 6'-5 5/8" 4'-6" 4'-6" 3'-6 1/2" 6'-5 1/2"

5' -0

5'

-0

6' -8

1'

-3

A-411

D1

L

L

L

L

L39

L39 L39 L39 L39 L39 L39

L

L

L

L

'-7

33'-0"

8"

VERIFY

6'-7 3/8"

VERIFY

5'-6"

6 TREADS AT 11" 9 3/4"

1 7/8" 2"

2' -7

/8

3'

-1

1/ 2"

1/

2" 5'

-0

5' -0

5'

-0

8" V

E R

IF

Y

6'-5 5/8" 4'-6"

8"

2'

-4

/2

3' -0

A-411

E4

'-0

ROOF LEVEL

26' - 6"

CT_FRAME

30' - 6"

L39

6'-7 1/2"

5'-9 3/4"

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural and Subconsultants:

KEY PLAN

NOT FOR

CONSTRUCTION

B

B

2058 S Dobson Rd., Suite 10, Mesa, AZ 85202

(480) 454-6408 www.unitedstr.com

B

IM

/5

-1

-1

O p ti m iz e

B

E n e rg y P la n t

/5

-1

-1

.4

.A

R C

H .r v t

/2 /2

:0

:1

P M

A-411

ARCHITECTURAL ENLARGED VIEWS AT ROOF

TRIPLE C THE A/E GROUP

2266 S. Dobson Road, Suite 200

Mesa, AZ 85202

(928) 499-3225

Mat Perkins

P2S ENGINEERING, INC.

5000 E. Spring Street

8th Floor

Long Beach, CA 90815-5218

Contact: Mikhail Fuks

UPGRADE ENERGY PLANT

EQUIPMENT INFRASTRUCTURE

(BLDG. 43 & 43A)

1501 SAN PEDRO SE ALBUQUERQUE, NM 87108

501-17-105

11/25/2019 M. PERKINS D. YOUNG

100% CONSTRUCTION

DOCUMENTS

3/8" = 1'-0" F7

STEPS AT COOLING TOWER ENCLOSURE

1 EXISTING ROOF DRAINS TO REMAIN

2 EXISTING MECHANICAL PIPE PENETRATIONS TO REMAIN

3 EXISTING COOLING TOWERS TO REMAIN, REFER TO MECHANICAL DRAWINGS FOR

ADDITIONAL INFORMATION

4 NEW COOLING TOWER PLATFORM

5 EXISTING GUY WIRE SUPPORT TO REMAIN

6 NEW STEEL STEPS WITH GRATING, PLATFORM ACCESS

7 NEW TIE BACK

8 NEW ROOF, TPO SINGLE PLY

9 MECHANICAL EQUIPMENT, REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL

INFORMATION

1/4" = 1'-0" D1

UPPER ROOF SCREEN WALL ELEVATION - EAST

1/4" = 1'-0" B1

UPPER ROOF SCREEN WALL ELEVATION - NORTH

1/4" = 1'-0" E1

UPPER ROOF SCREEN WALL ELEVATION - SOUTH

1/4" = 1'-0" F1

SCREEN WALL ELEVATION - NORTH

1/4" = 1'-0"

F3

SCREEN WALL ELEVATION - EAST

1/4" = 1'-0" F5

SCREEN WALL ELEVATION - SOUTH

3/8" = 1'-0" D5

ENLARGED ROOF PLAN AT ROOF SCREEN

Revisions: Date:

1/4" = 1'-0" E4

UPPER ROOF SCREEN WALL

ELEVATION - WEST

0 2'-0" 4'-0" 8'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

0 2'-0" 4'-0" 6'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

7/20/2022

MATHEW PERKINS

A-501

B7

A-501

B1

6"

A-501

B4

CANT STRIP

NEW ROOF

SYSTEM

NEW ROOF

STRUCTURE

NEW CONTINUOUS

TERMINATION BAR,

MAINTAIN CONSTANT

HEIGHT AT MINIMUM 8"

CLEAR FROM ROOF

SURFACE

MASONRY WALL & LINTEL,

SEE STRUCTURAL

DRAWINGS

8" M

IN

IM

U M

EXTEND ROOFING TO TOP OF

WALL, BENEATH CAP

ROOF SYSTEM CAP SHEET

EXTENDED OVER PARAPETVERIFY WITH MANUFACTURER

CONTINUOUS CANT STRIP OR BACKER

ROD

MIN. 60 MIL, TPO ROOFING

MEMBRANE,

FULLY ADHERED (TYP.)

MIN. 1/2" DENSDECK OR EQUAL

COVERBOARD, ADHERED

POLYISOCYANURATE INSULATION BOARD

(MIN. R-30 CONTINUOUS INSULATION AS REQUIRED

PER SPECS), ADHERED. PROVIDE TAPERED

INSULATION BOARD AS REQUIRED TO MAINTAIN A MIN.

1/4" PER 1'-0 SLOPE TO DRAIN AT ALL LOCATIONS.

EXISTING LIGHTWEIGHT CONCRETE TO

REMAIN AT EXISTING ROOF,

NEW CONCRETE PLANK AT NEW ROOF

VAPOR BARRIER

NOTES:

1. VAPOR BARRIER TO BE PART OF

THE OVERALL TESTED ROOFING

ASSEMBLY.

2. VAPOR BARRIER TO BE FLASHED

AND SEALED TO ALL

PENETRATIONS, DRAINS, CURBS,

ADJACENT WALLS, ETC.

3. SOLAR REFLECTIVITY INDEX TO

MEET ASHRAE 90.1 AND ENERGY

STAR REQUIREMENTS, MIN. SRI 82.

4. EXISTING LIGHTWEIGHT

CONCRETE TAPERS FROM 2" AT

LOW POINT TO 7" AT HIGH POINT

A-513

B4

1/2" FIRE-TREATED PLYWOOD

SHEATHING

MECHANICAL EQUIPMENT

LAP VERTICAL MIN. 60 MIL, TPO ROOFING

MEMBRANE LAYERS OVER CURB

OVERLAP HORIZONTAL MIN. 60 MIL, TPO

ROOFING MEMBRANE LAYERS AT VERTICAL

TRANSITION PER MANUFACTURER

RECOMMENDATIONS

SECURE LEVELED ROOF CURB TO

FIRE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .