36C26120R0007-0006003.xls
XLS spreadsheet Posted
- Attached to
- Install Anti-Ligature Door Alarms
- Solicitation number
- 36C26120R0007
About this file
This document contains three electrical panel inventory records and a notice of a federal contract opportunity to install anti-ligature door alarms. The contract opportunity solicitation seeks bids to install suicide deterrent and alarm systems on 75 doors across four Department of Veterans Affairs medical campuses in California, Hawaii, Nevada and Reno before March 2020. The self-monitoring systems must detect ligatures before pressure is applied, activate visual and audible alarms, and record at least 64 recent alarm events for review. Bids are due 30 days following issuance of the solicitation on December 30, 2019. The magnitude of construction is estimated between $500,000 and $1,000,000. The NAICS code is 238210 with a size standard of $16.5 million. The solicitation will be a total small business set-aside for Service-Disabled Veteran-Owned Small Businesses.
36C26120R0007 0006 3B313 revised 01-27-2020.xls
View the file
Other files
Show 40 more
Latest 50 of 53 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PNL 3B-2C2
| Electrical Panel Inventory | Name/Date | Lila Orrantia | 8/17/12 | ||||||||
| LOCATION | 3B313 | RPIE | PNL3B/2C2 | PNL NAME | 3B/2C2 | ||||||
| MANUFACT. | Westinghouse | # OF CKTS | 43 | MAX # CKTS | 46 | ||||||
| PNL TYPE | W10B Ckt. 42 | PNL AMPS | 100 | PNL VOLTS | 208Y/120V | ||||||
| PHASE | 3 | WIRE | 3 | NEUTRAL CAT. | 5158C03G04 | ||||||
| NEUTR AMPS | 225 | VOLT | SHRT CKT VLT | ||||||||
| BOX CAT NO. | YS2030 | BOX TYPE | N-1 | SHRT CKT AMP | 10K | ||||||
| JOB NO. | HL47200 IT.96 | MFT AT | VI | PNL BRD # | CY-328764 | ||||||
| FEEDER LOC | 3B313 | FEED PNL | 3B/4C2 Ckt. 2 | FEEDER AMP | 50 | ||||||
| Ckt# | Equipt Served | Poles | Amps | Equipt Served | Poles | Amps | Ckt# | ||||
| 1 | R - EXAM/TREAT 3B522 | 1 | 20 | R - TREAT CENTER 3B108 | 1 | 20 | 2 | ||||
| 3 | R - 3B508 | 1 | 20 | R - TREAT CENTER 3B121 | 1 | 20 | 4 | ||||
| 5 | M9608(Modular Headwall) 3B516 | 1 | 20 | M9608(Modular Headwall) 3B525 | 1 | 20 | 6 | ||||
| 7 | M9608(Modular Headwall) 3B518 | 1 | 20 | M9608(Modular Headwall) 3B523 | 1 | 20 | 8 | ||||
| 9 | M9608(Modular Headwall) 3B520 | 1 | 20 | M9608(Modular Headwall) 3B521 | 1 | 20 | 10 | ||||
| 11 | A301, 3B300A | 1 | 20 | M9608(Modular Headwall) 3B519 | 1 | 20 | 12 | ||||
| 13 | M9604(Modular Headwall) 3B506 | 1 | 20 | M9608(Modular Headwall) 3B517B | 1 | 20 | 14 | ||||
| 15 | M9609(Modular Headwall) 3B504 | 1 | 20 | M9608(Modular Headwall) 3B513 | 1 | 20 | 16 | ||||
| 17 | M9609(Modular Headwall) 3B504 | 1 | 20 | M9608(Modular Headwall) 3B505 | 1 | 20 | 18 | ||||
| 19 | S - OFF | 1 | 20 | M9608(Modular Headwall) 3B503 | 1 | 20 | 20 | ||||
| 21 | S - OFF | 1 | 20 | M9608(Modular Headwall) 3B501 | 1 | 20 | 22 | ||||
| 23 | S - OFF | 1 | 20 | S - OFF | 1 | 20 | 24 | ||||
| 25 | S - OFF | 1 | 20 | S - OFF | 1 | 20 | 26 | ||||
| 27 | S - OFF | 1 | 20 | S - OFF | 1 | 20 | 28 | ||||
| 29 | S - OFF | 1 | 20 | S - OFF | 1 | 20 | 30 | ||||
| 31 | S - OFF | 1 | 20 | S - OFF | 1 | 20 | 32 | ||||
| 33 | S - OFF | 1 | 20 | S - OFF | 1 | 20 | 34 | ||||
| 35 | S - OFF | 1 | 20 | NURSE CALL 3B311 | 1 | 20 | 36 | ||||
| 37 | S - OFF | 1 | 20 | NURSE CALL 3B111 | 1 | 20 | 38 | ||||
| 39 | S - OFF | 1 | 20 | S - OFF | 1 | 20 | 40 | ||||
| 41 | S - ON | 1 | 20 | S - OFF | 1 | 20 | 42 | ||||
| - | MAIN | 3 | 100 | ||||||||
| - | " " | ||||||||||
| - | " " | ||||||||||
| S = SPARE | L = LIGHTS | ||||||||||
| R = RECEPTACLE | PFB = PROV. FUTURE BKRS | ||||||||||
| CH=Cutler Hammer | CG=Challenger | GE=General Electric | SI=Siemens | ||||||||
| CP=Circle Products | FP=Federal Pacific | SD=Square D | WH=Westinghse | ||||||||
| Comments: | |||||||||||
| Updated 11/29/17 |
PNL 3B-2E
| Electrical Panel Inventory | Name/Date | LILA ORRANTIA 08/26/2013 | |||||||||
| LOCATION | 3B313 | RPIE | NONE | PNL NAME | 3B2E | ||||||
| MANUFACT. | Cutler Hammer | # OF CKTS | 25 | MAX # CKTS | 42 | ||||||
| PNL TYPE | PRL-1 | PNL AMPS | 225 | PNL VOLTS | 208/120 | ||||||
| PHASE | 3 | WIRE | 4 | NEUTRAL CAT. | K99649G02 | ||||||
| NEUTR AMPS | 225 | VOLT | 120 | SHRT CKT VLT | N/A | ||||||
| BOX CAT NO. | EZB2048R | BOX TYPE | 1 | SHRT CKT AMP | 10K | ||||||
| JOB NO. | SHL99257 | MFT AT | SES | PNL BRD # | HL112092 | ||||||
| FEEDER LOC | 3B313 | FEED PNL | 3B/4E | FEEDER AMP | 70 | ||||||
| Ckt# | Equipt Served | Poles | Amps | Equipt Served | Poles | Amps | Ckt# | ||||
| 1 | M5552 3B302 OFF | 3 | 90 | R8473(Refrigerator) 3B302 OFF | 2 | 40 | 2 | ||||
| 3 | " " | " " | 4 | ||||||||
| 5 | " " | R6850(Refrigerator) 3B302 | 1 | 20 | 6 | ||||||
| 7 | R - Nourishment Station - 3B509 | 1 | 20 | S - ON | 1 | 20 | 8 | ||||
| 9 | R - Nourishment Station - 3B509 | 1 | 20 | R6200+S6700 | 1 | 20 | 10 | ||||
| 11 | R - 6850 3B316A | 1 | 20 | M5250(Med Serv Cntr) 3B512 | 1 | 20 | 12 | ||||
| 13 | PNL 3D/2E OFF | 3 | 50 | S - OFF | 3 | 15 | 14 | ||||
| 15 | " " | " " | 16 | ||||||||
| 17 | " " | " " | 18 | ||||||||
| 19 | Door Access Equipment | 1 | 20 | FCU 3B309 | 1 | 20 | 20 | ||||
| 21 | CCTV Equipment | 1 | 20 | FCU 2B501 | 1 | 20 | 22 | ||||
| 23 | CCTV Equipment | 1 | 20 | EXHAUST FAN - OFF | 1 | 20 | 24 | ||||
| 25 | USCG - DENTAL CHAIR - OFF | 1 | 20 | USCG - DENTAL CONSOLE | 1 | 20 | 26 | ||||
| 27 | USCG - DENTAL CHAIR - OFF | 1 | 20 | USCG - DENTAL CONSOLE OFF | 1 | 20 | 28 | ||||
| 29 | USCG - VACUUM PUMP OFF | 2 | 40 | USCG - DENTAL CONSOLE OFF | 1 | 20 | 30 | ||||
| 31 | " " | RELOCATED AIR COMPRESSOR OFF | 2 | 30 | 32 | ||||||
| 33 | JB FOR MASTER CONTROL OFF | 1 | 20 | " " | 34 | ||||||
| 35 | - PFB | S - OFF | 1 | 20 | 36 | ||||||
| 37 | - PFB | - PFB | 38 | ||||||||
| 39 | - PFB | - PFB | 40 | ||||||||
| 41 | - PFB | - PFB | 42 | ||||||||
| 150A | MAIN LOCATED ON TOP ON PANEL | ||||||||||
| S = SPARE (OFF) | L = LIGHTS | * = NO LABEL, NO MARK. | |||||||||
| R = RECEPTACLE | PFB = PROV. FUTURE BKRS | ** = NO LABEL. | |||||||||
| CH=Cutler Hammer | CG=Challenger | GE=General Electric | SI=Siemens | ||||||||
| CP=Circle Products | FP=Federal Pacific | SD=Square D | WH=Westinghse | ||||||||
| Comments: | |||||||||||
| Updated 11/29/17 |
PNL 3B-2N
| Electrical Panel Inventory | Name/Date | Adam Sullivan 3-17-05 | |||||||||
| LOCATION | 3B313 | RPIE | PNL3B/2N | PNL NAME | 3B/2N | ||||||
| MANUFACT. | Westinghouse | # OF CKTS | 36 | MAX # CKTS | 42 | ||||||
| PNL TYPE | W10B Ckt. 42 | PNL AMPS | 100 | PNL VOLTS | 208/120 | ||||||
| PHASE | 3 | WIRE | 4 | NEUTRAL CAT. | 5158C03G04 | ||||||
| NEUTR AMPS | 225 | VOLT | 120 | SHRT CKT VLT | |||||||
| BOX CAT NO. | YS3039 | BOX TYPE | N-1 | SHRT CKT AMP | 10K | ||||||
| JOB NO. | HL47200 IT.99 | MFT AT | VI | PNL BRD # | CY - 320535 | ||||||
| FEEDER LOC | 3B313 | FEED PNL | 3B/4N Ckt. 13 | FEEDER AMP | 100 | ||||||
| Ckt# | Equipt Served | Poles | Amps | Equipt Served | Poles | Amps | Ckt# | ||||
| 1 | R - 3B527 | 1 | 20 | M9608(Modular Headwall) 3B525 | 1 | 20 | 2 | ||||
| 3 | R - 3B528 | 1 | 20 | M9608(Modular Headwall) 3B523 | 1 | 20 | 4 | ||||
| 5 | R - 3B524, 526 | 1 | 20 | M9608(Modular Headwall) 3B521 | 1 | 20 | 6 | ||||
| 7 | R - 3B522 | 1 | 20 | M9608(Modular Headwall) 3B519 | 1 | 20 | 8 | ||||
| 9 | R - 3B522 | 1 | 20 | M9608(Modular Hdwall) 3B517, 517B | 1 | 20 | 10 | ||||
| 11 | M9609(Modular Headwall) 3B520 | 1 | 20 | M9608(Modular Headwall) 3B513 | 1 | 20 | 12 | ||||
| 13 | M9609(Modular Headwall) 3B518 | 1 | 20 | R - 3B509, 511 | 1 | 20 | 14 | ||||
| 15 | R - 3B514, 516 | 1 | 20 | M9608(Modular Headwall) 3B505 | 1 | 20 | 16 | ||||
| 17 | R - 3B510, 512 | 1 | 20 | M9608(Modular Headwall) 3B503 | 1 | 20 | 18 | ||||
| 19 | R - 3B508 | 1 | 20 | M9608(Modular Headwall) 3B501 | 1 | 20 | 20 | ||||
| 21 | M9609(Modular Headwall) 3B506 | 1 | 20 | R - 3B515 | 1 | 20 | 22 | ||||
| 23 | M9609(Modular Headwall) 3B504 | 1 | 20 | R - 3B301, 303, 305, 307 | 1 | 20 | 24 | ||||
| 25 | M9609(Modular Headwall) 3B504 | 1 | 20 | R - F7041 3B322 | 1 | 20 | 26 | ||||
| 27 | R - 3B502 | 1 | 20 | R - 3B309 | 1 | 20 | 28 | ||||
| 29 | R - 3B500A | 1 | 20 | BRIDGE R | 1 | 20 | 30 | ||||
| 31 | BRIDGE | 1 | 20 | R - 2205(Water Cooler) 3B506 | 1 | 15 | 32 | ||||
| 33 | 3B300A MAGNET OFF | 1 | 20 | STATION 430 3B510 | 1 | 20 | 34 | ||||
| 35 | R - 3B116/118 | 1 | 20 | R - 3B123/127/127A | 1 | 20 | 36 | ||||
| 37 | R - 3B116/118 | 1 | 20 | R - 3B129A | 1 | 20 | 38 | ||||
| 39 | R - 3B116/118 | 1 | 20 | R - 3B129A | 1 | 20 | 40 | ||||
| 41 | R - 3B116 | 1 | 20 | S - OFF | 1 | 20 | 42 | ||||
| MAIN | 3 | 100 | |||||||||
| " " | |||||||||||
| " " | |||||||||||
| . | |||||||||||
| S = SPARE (OFF) | L = LIGHTS | * = NO LABEL, NO MARK. | |||||||||
| R = RECEPTACLE | PFB = PROV. FUTURE BKRS | ** = NO LABEL. | |||||||||
| CH=Cutler Hammer | CG=Challenger | GE=General Electric | SI=Siemens | ||||||||
| CP=Circle Products | FP=Federal Pacific | SD=Square D | WH=Westinghse | ||||||||
| Comments: | |||||||||||
| Updated 11/30/17 |