This document outlines requirements for a federal contract solicitation to install anti-ligature door alarms at multiple Department of Veterans Affairs medical centers. The contractor shall provide, install, and integrate a suicide deterrent and alarm system to detect ligature attempts on doors. The system must detect ligatures before pressure is applied and include visual and audible alarms. It shall record and display recent alarm events. Installation locations include 29 doors at the VA Northern California Health Care System in Mather, 12 doors at the VA Pacific Islands Health Care System in Honolulu, 20 doors at the VA Central California Health Care System in Fresno, and 14 doors at the VA Sierra Nevada Health Care System in Reno. The period of performance is 150 days from notice to proceed. The estimated contract value is between $500,000 and $1,000,000. The solicitation will be issued on or around December 30, 2019 and posted on Federal Business Opportunities. Proposals will be due 30 days after issuance unless extended. The solicitation will be a total small business set-aside for service-disabled veteran-owned small businesses.

36C26120R0007 0006 Revised Statement of Bid Items from Specs.pdf

View the file

Other files

File Type Posted
36C26120R0007-0007002.pdf PDF
36C26120R0007-0007001.pdf PDF
36C26120R0007-0007000.docx DOCX document
36C26120R0007-0006005.pdf PDF
36C26120R0007-0006015.pdf PDF
36C26120R0007-0006013.pdf PDF
36C26120R0007-0006009.pdf PDF
36C26120R0007-0006014.pdf PDF
36C26120R0007-0006000.docx DOCX document
36C26120R0007-0006006.pdf PDF
36C26120R0007-0006003.xls XLS spreadsheet
36C26120R0007-0006008.zip ZIP file
36C26120R0007-0006002.pdf PDF
36C26120R0007-0006012.pdf PDF
36C26120R0007-0006007.pdf PDF
36C26120R0007-0006010.zip ZIP file
36C26120R0007-0006004.pdf PDF
36C26120R0007-0006011.pdf PDF
36C26120R0007-0005000.docx DOCX document
36C26120R0007-0004008.pdf PDF
36C26120R0007-0004002.pdf PDF
36C26120R0007-0004000.docx DOCX document
36C26120R0007-0004009.docx DOCX document
36C26120R0007-0004004.pdf PDF
36C26120R0007-0004006.pdf PDF
36C26120R0007-0004011.docx DOCX document
36C26120R0007-0004005.pdf PDF
36C26120R0007-0004007.pdf PDF
36C26120R0007-0004001.docx DOCX document
36C26120R0007-0004003.pdf PDF
36C26120R0007-0004010.docx DOCX document
36C26120R0007-0003000.docx DOCX document
36C26120R0007-0002000.docx DOCX document
36C26120R0007-0001000.docx DOCX document
36C26120R0007-012.pdf PDF
36C26120R0007-010.docx DOCX document
36C26120R0007-013.docx DOCX document
36C26120R0007-006.pdf PDF
36C26120R0007-018.pdf PDF
36C26120R0007-003.pdf PDF
36C26120R0007-004.pdf PDF
36C26120R0007-020.docx DOCX document
36C26120R0007-017.docx DOCX document
36C26120R0007-019.pdf PDF
36C26120R0007-016.pdf PDF
36C26120R0007-009.pdf PDF
36C26120R0007-014.pdf PDF
36C26120R0007-008.pdf PDF
36C26120R0007-011.pdf PDF
36C26120R0007-007.docx DOCX document
Show 40 more

Latest 50 of 53 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

12-01-18

01 00 00 -2

1.3 STATEMENT OF BID ITEM(S)

A. ITEM I, Installation at VASNHCS, Reno: Work includes all efforts of general construction and alterations to complete the work outlined in the SOW for Fourteen existing wood doors (14).

Special considerations/requirements at this site are: none

B. ITEM II, Installation at VANCHCS, Mather: Work includes all efforts of general construction and alterations to complete the work outlined in the SOW for twenty-nine existing Hollow Metal doors (29).

Special considerations/requirements at this site are: anti-ligature alarm shall include Two sets of sensors at the top of the door at door and frame and one set of sensors at the bottom at the undercut of the door. Contractor shall install three new dedicated breakers and circuits for the system located in B726 electrical room to provide the required new power to the control panel/monitoring panel. Contractor shall label and relabel any junction boxes for wiring related to this project. All conduit and related work shall be color coded using a tape or paint to identify the wiring and cabling for this project’s infrastructure.

C. ITEM III, Installation at VACCHCS, Fresno: Work includes all efforts of general construction and alterations to complete the work outlined in the SOW for twenty existing doors (20) in inpatient psychiatry (6E).

Special considerations/requirements at this site are: none

C. ITEM IV, Installation at VAPIHCS, Honolulu: Work includes all efforts of general construction and alterations to complete the work outlined in the SOW for Twelve existing wood doors (12) in the VA Mental Health

/ Psychiatric Ward 3B2 located at the Tripler Army Medical Center at

Tripler Army Medical Center (TAMC).

Special considerations/requirements at this site are: anti-ligature alarm shall include Two sets of sensors at the top of the door at door and frame and one set of sensors at the bottom at the undercut of the door.

Contractor shall install new power to meet demand of provided equipment from electrical closet on seen on plan.

VHARENBARRM

Cross-Out

VHARENBARRM

Cross-Out