055000-6.0_Metal Fabrications-Suicide Fence-SD_ASI_ACG.pdf

PDF 264 KB Posted

Attached to
Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)
Solicitation number
36C25926R0082_1
Issued by

About this file

This is a technical drawing and submittal document for a 4-foot square aluminum fence panel with mesh infill, prepared by MFR Manufacturing Corporation, Inc. for the Veterans Affairs Medical Center (VAMC) Oklahoma City facility. The panel features a 4-foot by 4-foot frame with a 3-foot 8-inch by 3-foot 8-inch mesh infill area, with a 4-inch opening at the top. The frame is constructed with 1-inch edges and uses aluminum mesh with 4-inch by 4-inch spacing. The finish specification is powder coating in black.

The document includes comprehensive technical specifications, a bill of materials, connection details, and general notes regarding fabrication tolerances (±1/4 inch on all dimensions), field verification requirements, and installation responsibilities. Key contractual provisions specify that the customer is responsible for verifying all dimensions before fabrication, that surrounding structural support must be designed to withstand transmitted forces, and that mechanical fasteners are the installer's responsibility unless otherwise noted. The document requires customer signature and approval with red-line marking of any necessary changes. MFR Manufacturing Corporation retains all design and intellectual property rights to the drawings. The submittal is dated April 1, 2025, with fabrication coordinated by drawing verification procedures outlined on subsequent pages.

View the file

Other files

File Type Posted
36C25926R0082 Amend 0007.pdf PDF
019100-2022-04 general comissioning requirements.docx DOCX document
280800-2016-11 comissioning of electronic and security systems.docx DOCX document
635-21-139 Questions and Responses 3.docx DOCX document
36C25926R0082Amend 0006.pdf PDF
36C25926R0082 Amend 0005.pdf PDF
36C25926R0082 0004.pdf PDF
055000-2.0_Metal Fabrications-SD_ASI_ACG_VA.pdf PDF
635-21-139 Questions and Responses 2.docx DOCX document
36C25926R0082 0003.docx DOCX document
635-21-139 2nd Site visit Sign in sheet 08-25-2026.pdf PDF
36C25926R0082 0002.docx DOCX document
2nd Site Visit Meeting Doc_635-21-139 Repair Parking Garage 1.docx DOCX document
Terracon Project No. 03235201 Rev 1 VAMC Parking Garage Stair Tower GEO ENG RPT 12-19-2024 - signed.pdf PDF
S04- 635-21-139 Site Visit Sign in sheet 07-29-2026.pdf PDF
S06- 36C25926R0082 0001.docx DOCX document
Site Visit Meeting Doc_635-21-139 Repair Parking Garage 1.docx DOCX document
635-21-139 Questions and Responses.docx DOCX document
36C25926R0082_1.docx DOCX document
S02 - Prime and Sub Contractor Construction Breakdown.xlsx XLSX spreadsheet
635-21-139 OKC PARKING GARAGE Combined Drawings.pdf PDF
S22 LOS Certification 852.219-75_JAN 2023 DEVIATION.docx DOCX document
S02-3-10-2021 Past Performance Questionnaire_Blank_Fillable PDF.pdf PDF
Site Map for site visit 635-21-139.pdf PDF
00-Specifications 635-21-139.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

" [1

08]

OC

1 4"

8] O

C

4" [10

1] O

PEN

ING

2"

4'-0" [1219] FRAME WIDTH

3'-8" [1118] MESH INFILL WIDTH

3' -8

[1

M

ES

H

IN

FI

LL

H

EI

G

HT

4' -0

[1

9] F

RA

M E

HE

IG

HT

1" [25]

3"

3"

4'-0" [1219] FRAME WIDTH

3'-8" [1118] MESH INFILL WIDTH

1 14" [32] 4" [19]

FRONT VIEW

TOP VIEW

FRONT VIEW

1" [25] 1 14" [32]

2"

3 4"

2"

4"

2]

2 1 4" [58]

R 58 " [R16]

158" [41]

DRAWN BY: CHECKED BY:

DATE:SCALE:

JOB NO.

SHEET NO.

S

IL

L

AV

E, A

UR

OR

A

IL

(8

2-

W W

W .M

FR

CO

RP

.C

O M

V A

M C

O K

C

M A S T E R S

H E E T

C O N N E C T

IO

N D

E T A

IL

B

IL

L O

F M

A T E R

IA

L C

H A R T

4/1/2025AS NOTED

BB GM

A1PLEASE INITIAL AND DATE THE FOLLOWING PAGES ON THE BOTTOM RIGHT HAND

CORNER FOR THE PURPOSE OF DRAWING VERIFICATION.

CUSTOMER SIGNATURE AND APPROVAL

DATE SIGNED

APPROVED BY DATE SENT

SUBMITTAL #

( SIGNATURE )

GENERAL ABBREVIATIONS

AFF = ABOVE FINISHED FLOOR

= ARCHITECTARCH.

B.O. = BY OTHERS

B.P. = BASE PLATE

= BAR DIRECTION

= CENTER LINECL

CLR = CLEARANCE

CMU = CONCRETE MASONRY UNIT

DIM = DIMENSIONS

Ø = DIAMETER

(E) = EXISTING

FCTF = FIELD CUT TO FIT

FH = FRAME HEIGHT

FL = FLOOR

FS = FAR SIDE

FW = FRAME WIDTH

GC = GENERAL CONTRACTOR

GL = GROUND LEVEL

ITI

H = HEIGHT

= INSIDE TO INSIDE

(OPENING)

L = LENGTH

L1 = OPENING

L2 = PANEL WIDTH

NS = NEAR SIDE

OC = ON CENTER

O.H. = OPPOSITE HAND

O/O = OWNER/OPERATOR

OTO = OUTSIDE TO OUTSIDE

(OPENING)

P = PANEL

PL = PLATE

R.O. = ROUGH OPENING

TYP. = TYPICAL

VIF = VERIFY IN FIELD

WIF = WELD IN FIELD

R E V B

Y R E V

D A T E

R E V

IS

E D I T E M S

R E V

N O - - - -

DRAWING INDEX

FINISH: POWDER COATED

COLOR: BLACK

INFORMATION PROVIDED ON THIS DRAWING DOCUMENT ARE VITAL TO THE

CUSTOMER AND MFR MANUFACTURING CORPORATION, INC.. THE PRODUCTION OF

THE COMPONENTS ARE DEPENDENT UPON THE ACCURACY OF INFORMATION

PROVIDED TO MFR MANUFACTURING CORPORATION, INC. BY THE CUSTOMER. PLEASE

REVIEW THE MEASUREMENTS IN THE DRAWINGS CAREFULLY, VERIFY THEM IN THE

FIELD, DISCUSS AND CHECK THEM WITH YOUR DESIGNER AND CONTRACTOR.

INDICATE NECESSARY CHANGES IN RED MARKS. UPON SIGNING THIS BOX, IT WILL

SUPERSEDE ALL SIGNED AND AFFIXED STAMPS USED BY THE CUSTOMER FOR THEIR

OWN PURPOSES AND OFFICE PROCEDURES. CHANGES AFTER APPROVAL MAY INCUR

ADDITIONAL COSTS AND DELAYS IN PRODUCTION. FAILURE OF CUSTOMER TO COMPLY

WITH THIS REQUEST RELIEVES MFR OF ANY RESPONSIBILITY RESULTING FROM

ANY ERROR.

THESE DRAWINGS IN DESIGN AND DETAIL ARE THE SOLE

PROPERTY OF MFR MANUFACTURING CORPORATION, INC. AND MAY NOT BE USED

FOR ANY PURPOSE WHATSOEVER OTHER THAN FOR OUR MANUFACTURING FACILITY

AND INSTALLATION OF OUR PRODUCTS. THESE DOCUMENTS OR ANY PART THEREOF

MAY NOT BE REPRODUCED IN ANY MANNER WHATSOEVER AND SHALL BE RETURNED

TO US UPON REQUEST.

ALL RIGHTS RESERVED.

1) CUSTOMER WILL SPECIFY, APPROVE, VERIFY IN FIELD, AND GUARANTEE ALL DIMENSIONS SHOWN ON THESE DRAWINGS BEFORE FABRICATION.

REQUIRED ARCHITECTURAL DIMENSIONS OF FENCES, RAILINGS AND SCREENS PROVIDED BY CUSTOMER.

THEY SHOULD MEET ALL THE APPLICABLE BUILDING CODES REQUIRED BY LOCAL, STATE & OTHER REGULATORY AGENCIES.

2)

UNLESS OTHERWISE INDICATED IN THE PLAN, ALL MECHANICAL FASTENERS ARE TO BE SUPPLIED BY AND RESPONSIBILITY OF THE INSTALLER.3) MFR MANUFACTURING CORPORATION, INC. ASSUMES NO RESPONSIBILITY FOR THE DESIGN, CONSTRUCTION OR INSTALLATION OF ANY MATERIALS SUPPLIED BY OTHERS.4) ANY ADDITIONAL STRUCTURAL MEMBERS SUCH AS GUSSETS, BRACES, KICKERS, EMBEDS AND STIFFENERS, THAT MAY BE REQUIRED

ARE NOT THE RESPONSIBILITY OF MFR MANUFACTURING CORPORATION, INC.

5)

ACCIDENTAL DAMAGES & DEFECTS RESULTING FROM IMPROPER INSTALLATION AND VANDALISM ARE NOT COVERED UNDER THE WARRANTY

PROVIDED BY MFR MANUFACTURING CORPORATION, INC.

6)

ANY CLOUDED AREA IN THE DRAWING MUST BE REVIEWED. ADVISE MFR MANUFACTURING CORPORATION, INC. IN WRITING OF THE SUGGESTIONS OR BY REDLINING AND SIGNING THE DRAWINGS WITH THE ALTERNATIVE SOLUTIONS OR OPTIONS REGARDING THE MATTER.

7)

ALL THE SURROUNDING STEEL, CONCRETE, CMU, PRECAST STRUCTURES, SUPPORT, FRAMES, COLUMNS OR POSTS MUST BE DESIGNED

TO WITHSTAND ALL RESULTANT FORCES TRANSMITTED BY THE PANEL SCREENS AND RAILINGS.

8)

9)

ALL OF THE ELEVATIONS AND DETAILS DRAWN ILLUSTRATE WELDED ROD ON THE NEARSIDE, EXCEPT WHEN NOTED OTHERWISE.10) DIMENSION ALLOWANCE ON FABRICATION TOLERANCE IS +/- 1/4" (+/- 5mm) ON ALL DIMENSIONS.11)

THE MESH DRAWN BY HATCHES ARE SHOWN FOR ILLUSTRATION INTENT ONLY. DO NOT SCALE NOR MEASURE THE MESHES.

MESH SPACINGS ARE SPECIFIED ON THE ISOMETRIC (OR 2-D) PANEL DRAWING SHOWN ON THE UPPER RIGHT HAND SIDE OF THE SHEET.

ALIGNMENT OF MESHES ON SLOPED AND STRAIGHT PANELS MAY VARY DUE TO FIELD CONDITIONS AND SOME FACTORS ENCOUNTERED IN THE FIELD SUCH AS, BUT NOT LIMITED TO, CONSTRUCTION ERRORS, MISFITS, OR IRREGULARITIES.

MFR RESERVES THE RIGHT TO MAKE MINOR CHANGES AND ADJUSTMENTS IN ORDER TO ACCOMMODATE PRODUCTION AND MACHINE LIMITATIONS. THESE CHANGES WILL NOT IMPACT THE FUNCTION, ORIGINAL DESIGN INTENT OR OVERALL APPEARANCE.

12)

GENERAL NOTES

SOME FIELD MODIFICATIONS AND WELDING MAY BE REQUIRED.13)

4"x4" ALUMINUM MESH ISOMETRIC DETAIL

ALL HARDWARE INCLUDING FASTENERS, BOLTS, SCREWS, WASHERS, AND SIMILAR ITEMS ARE UNFINISHED AND USUALLY APPEAR AS ZINC-PLATED, GALVANIZED, OR CHROME-PLATED COLOR UNLESS OTHERWISE NOTED IN DRAWINGS

14)

4' SQ. ALUMINUM FENCE PANEL DETAIL

PANEL CONNECTION DETAIL

4/1/2025

AutoCAD SHX Text

14" ALUMINUM ROD TYPICAL

AutoCAD SHX Text 14" ALUMINUM ROD MESH 4"x4" OPENING SIZE ROD ENDS CAPTURED IN FRAME WELDED TO FRAME

AutoCAD SHX Text 2"x2"x " ALUMINUM TUBE 18" ALUMINUM TUBE PANEL FRAME

AutoCAD SHX Text 2 "x2"x " ALUMINUM PANEL ATTACHMENT TABS 14"x2"x " ALUMINUM PANEL ATTACHMENT TABS 14" ALUMINUM PANEL ATTACHMENT TABS WELDED TO BACK FACE OF FRAME HARDWARE/ANCHORS BY OTHERS

AutoCAD SHX Text

EXTERIOR

AutoCAD SHX Text

14" THK AL PLATE

AutoCAD SHX Text

CONTENTS:

AutoCAD SHX Text

PROJECT:

AutoCAD SHX Text

ADDRESS:

AutoCAD SHX Text

MASTER SHEET, ELEVATION, BILL OF MATERIAL, DETAIL & CHART

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text A1

AutoCAD SHX Text 3" = 1'-0"

AutoCAD SHX Text A1

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text A1

AutoCAD SHX Text 1-1/2" = 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text A1

AutoCAD SHX Text 6" = 1'-0" amayo Received