AD103 ADD 1.pdf
PDF 282 KB Posted
- Attached to
- Z2NB-- Project 667-18-101 Correct Tunnel Discrepancies Federal contract opportunity
- Solicitation number
- 36C25621R0158
About this file
This solicitation requests proposals for Correct Tunnel Discrepancies, Project No. 667-18-101 at the Overton Brooks VA Medical Center. The contractor shall provide all labor, materials, tools and equipment to perform the work described in the project scope of work, drawings and specifications. The anticipated contract value is between $500,000 and $1,000,000.
The solicitation will be issued as a 100% SDVOSB set-aside and proposals are due on August 15, 2021. A site visit will be held on or around July 15, 2021. The contract performance period is 200 calendar days from the notice to proceed. Interested offerors must be registered and verified as a SDVOSB in the Vendor Information Pages database and System for Award Management at the time of proposal submission. The solicitation number is 36C25621R0158 and will be posted on beta.SAM. The work location is 510 E. Stoner Ave, Shreveport, LA 71101 and is issued by the Department of Veterans Affairs Veterans Health Administration VISN 16.
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TUNNEL FFE
-11' - 4 1/2"
TUNNEL ROOF
-3' - 4 1/2"
F.
V.
7'
0"
F.V.
6' - 0"
10" HPS
8" PCR
18" CHS
12" HPS
8" DCW
18" CHR
TUNNEL FFE
-11' - 4 1/2"
TUNNEL ROOF
-3' - 4 1/2"
F.
V.
7'
0"
F.V.
6' - 0"
18" CHS
8" PCR
10" HPS
18" CHS
12" HPS
8" DCW
GARAGE FFE
0' - 0"
TUNNEL FFE
-11' - 4 1/2"
F.
V.
/2
F.V.
6' - 0"
F.V.
2' - 6"
F.V.
1' - 6"
F.V.
2' - 0"
GARAGE
SIDE
2" HPS
12" HPS
8" DCW
4" PCR
10" HPS
8" PCR
NOT FOR
CONSTRUCTION
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C :\U se rs
\ts te ve ns
\R ev it Lo ca l\C om pl et ed
J ob s\ D
-1 8-
_6
-1
8-
1_ C or re ct T un ne l D is cr ep an ci es \6
-1
8-
1_ Tu nn el
_A rc h_ to dd .s te ve ns .rv t 9/
3/
0:
:2
AM
AD103
DEMOLITION SECTIONS
JohnsonDanforth & Associates 2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811 www.johnsondanforth.com
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 JM TS
3/8" = 1'-0"C4
TUNNEL SECTION @ BUILDING #1 -
DEMO
3/8" = 1'-0"E4 TUNNEL SECTION @ DRIVE - DEMO
3/8" = 1'-0"D7 TUNNEL SECTION @ GARAGE - DEMO
DEMO KEYED NOTES
1 EXISTING CONCRETE TUNNEL WALL TO REMAIN; PROTECT DURING DEMO & NEW CONSTRUCTION UNLESS OTHERWISE NOTED.
2 EXISTING CONCRETE TUNNEL FLOOR TO REMAIN; PROTECT DURING DEMO & NEW CONSTRUCTION UNLESS OTHERWISE NOTED.
3 EXISTING CONCRETE TUNNEL CEILING TO REMAIN; PROTECT DURING DEMO & NEW CONSTRUCTION UNLESS OTHERWISE NOTED.
4 EXISTING ACCESS LADDER TO REMAIN; PROTECT DURING DEMO & NEW CONSTRUCTION UNLESS OTHERWISE NOTED.
5 EXISTING TUNNEL WALL EXPANSION JOINT; REMOVE ALL EXISTING SEALANT AND PREPARE SURFACE FOR NEW SEALANT (SEE DETAIL B8/AE101).
6 ACM ON EXISTING HIGH PRESSURE STEAM PIPING, TO BE ABATED.
7 ACM ON EXISTING PUMP CONDENSATE RETURN PIPING, TO BE ABATED.
8 ACM ON EXISTING CHILLED WATER SUPPLY PIPING, TO BE ABATED.
9 ACM ON EXISTING CHILLED WATER RETURN PIPING, TO BE ABATED.
10 EXISTING PIPE SUPPORT ASSEMBLY TO BE REMOVED; CONTRACTOR RESPONSIBLE FOR VERIFYING QUANTITIES WITH VA PRIOR TO DEMO; PROVIDE SHORING AND/OR SUPPORT FOR
PIPING AS REQUIRED DURING DEMO AND NEW CONSTRUCTION.
11 EXISTING CLAY BLOCK TUNNEL WALL TO REMAIN; PROTECT DURING DEMO AND NEW CONSTRUCTION.
12 ACM ON EXISTING DOMESTIC COLD WATER, TO BE ABATED.
GENERAL NOTES:
1. REFER TO MECHANICAL AND ELECTRICAL SHEETS FOR INFORMATION ON ALL
PIPING, CONDUIT, LIGHTING, OR OTHER UTILITY INFRASTRUCTURE.
2. REFER TO STRUCTURAL SHEETS FOR INFORMATION NEW CONSTRUCTION OF
PIPING STRUCTURES.
3. CONTRACTOR RESPONSIBLE FOR FIELD VERIFYING (F.V.) ALL EXISTING
CONDITIONS AND QUANTITIES PRIOR TO BIDDING.
D1
TYPICAL PIPING SUPPORT ASSEMBLY -
DEMO
1 1 2 3 4 5 6 7 3/8" = 1'-0"
FEETSCALE
ADDENDUM 1 DATE: 09.02.2021
| Sheets |
| AD103 - DEMOLITION SECTIONS |
File details come from the government source that posted it. Updated .