This federal contract opportunity document outlines a requirement for construction services. The Overton Brooks VA Medical Center is seeking a contractor to correct tunnel discrepancies at their facility located in Shreveport, Louisiana under project number 667-18-101. The anticipated period of performance is 200 calendar days with an expected contract award date approximately 30 days after the August 15th proposal due date. The procurement will be conducted as a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Offerors must be verified in the Vendor Information Pages database and registered in SAM.gov to be considered for award. The construction cost range is between $500,000 to $1,000,000 and NAICS code 236220 for commercial and institutional building construction applies.
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL INFORMATION ADHESIVE SET ANCHORS, REINFORCING
BARS, & DOWEL NOTES
A. CONCRETE ANCHORS
I. MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED
FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193 FOR
CRACKED AND UNCRACKED CONCRETE RECOGNITION.
II. ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR
USE IN ACCORDANCE WITH ACI 355.4 AND ICC-ES AC308 FOR
CRACKED AND UNCRACKED CONCRETE RECOGNITION.
SUBMIT FOR APPROVAL ANCHORING SYSTEM FOR ATTACHMENT TO HOLLOW
AND GROUT-FILLED MASONRY UNITS.
SUBMIT FOR APPROVAL ANCHORING SYSTEM FOR ATTACHMENT INTO
SOLID SURFACES ONLY. (E.G., SOLID CONCRETE )
SUBMIT FOR APPROVAL ANCHORING SYSTEM FOR REBAR AND DOWEL
EMBEDMENT.
USE MANUFACTER'S THREADED RODS OR APPROVED EQUAL UNLESS
SPECIFICALLY NOTED OTHERWISE. SUBSTITUTION OF A-36 ALL-THREAD ROD
WILL NOT BE ALLOWED. RODS ANCHORING INTO UNREINFORCED MASONRY
SHALL BE BENT AT 22 1/2° ANGLE UNO.
WHERE BASE MATERIAL IS HOLLOW BLOCK, BRICK OR OTHER MATERIAL
CONTAINING POCKETS OR VOIDS, A SCREEN TUBE, PER MANUFACTURERS
RECOMMENDATIONS, SHALL BE EMPLOYED IN THE SYSTEM.
1.
2.
3.
4.
5.
FOLLOW MANUFACTURERS REQUIREMENTS FOR MINIMUM DEPTH OF BASE
MATERIAL, MINIMUM EDGE DISTANCES, AND MINIMUM BOLT/BAR SPACING.
6.
UNLESS SPECIFIED OTHERWISE, ANCHORS SHALL BE EMBEDDED IN THE
APPROPRIATE SUBSTRATE WITH A MINIMUM EMBEDMENT OF 8 TIMES THE
NOMINAL ANCHOR DIAMETER OR THE EMBEDMENT DEPTH REQUIRED TO
SUPPORT THE INTENDED LOAD.
7.
POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM
THE ENGINEER-OF-RECORD PRIOR TO INSTALLING POST-INSTALLED ANCHORS IN
PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE SHALL BE
TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH
EXISTING REINFORCING. HOLES SHALL BE DRILLED AND CLEANED IN
ACCORDANCE WITH THE MANUFACTURER’S WRITTEN INSTRUCTIONS.
SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW
SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER-OF-RECORD
ALONG WITH CALCULATIONS THAT ARE PREPARED & SEALED BY A REGISTERED
PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL DEMONSTRATE THAT THE
SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERTINENT EQUIVALENT
PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE
APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE
BUILDING CODE. PROVIDE CONTINUOUS SPECIAL INSPECTION FOR ALL ADHESIVES
AND MECHANICAL ANCHORS PER THE PRODUCT’S APPLICABLE ICC-ES OR IAPMO-
ES EVALUATION REPORT (ICC-ES ESR). CONTACT MANUFACTURER’S
REPRESENTATIVE FOR THE INITIAL TRAINING AND INSTALLATION OF ANCHORS AND
FOR PRODUCT RELATED QUESTIONS AND AVAILABILITY.
8.
1. SUBSTITUTION OF EXPANSION OR ADHESIVE ANCHORS FOR EMBEDDED
ANCHORS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY APPROVED IN
WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO PLACING OF
CONCRETE CONTAINING THE ANCHORS.
2. PERMANENT STABILITY OF THE BUILDING AND COMPONENTS IS NOT
PROVIDED UNTIL THE ERECTION IS COMPLETED AS SHOWN ON THE
CONTRACT DRAWINGS. PER SECT 7.10.3 OF AISC CODE OF STANDARD
PRACTICE FOR BUILDINGS AND BRIDGES MARCH 18, 2005. "TEMPORARY
SUPPORTS, SUCH AS TEMPORARY GUYS, BRACES, FALSEWORK, CRIBBING OR
OTHER ELEMENTS REQUIRED FOR THE ERECTION OPERATION WILL BE
DETERMINED, FURNISHED AND INSTALLED BY THE ERECTOR."
3. WEIGHTS OF MECHANICAL EQUIPMENT SHOWN ON THE STRUCTURAL PLANS
ARE FOR UNITS SPECIFIED BY THE MECHANICAL ENGINEER. CONTRACTOR
SHALL VERIFY WEIGHTS AND ANY SUBSTITUTIONS THAT RESULT IN INCREASED
WEIGHT SHALL BE APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
4. THE CONTRACTOR SHALL INSURE THAT NO CONSTRUCTION LOAD EXCEEDS
THE DESIGN LIVE LOADS INDICATED ON THE STRUCTURAL DRAWINGS AND THAT
THESE LOADS ARE NOT PLACED ON THE STRUCTURAL MEMBERS PRIOR TO THE
TIME THAT ALL FRAMING MEMBERS AND THEIR CONNECTIONS ARE IN PLACE.
5. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION TO BE
COORDINATED WITH THE STRUCTURAL DRAWINGS.
6. PRIOR TO FABRICATION AND/OR ERECTION OF ANY MATERIALS, THE
CONTRACTOR SHALL FIELD VERIFY ALL PERTINENT EXISTING DIMENSIONS,
ELEVATIONS, AND CONDITIONS AND SHALL REPORT ANY DISCREPANCIES TO
THE STRUCTURAL ENGINEER OF RECORD OR THE ARCHITECT IMMEDIATELY
UPON DISCOVERY.
7. THE GENERAL CONTRACTOR SHALL VERIFY THE SITE CONDITIONS INCLUDING
UNDERGROUND UTILITIES BEFORE STARTING WORK AND SHALL NOTIFY THE
STRUCTURAL ENGINEER OF RECORD OF ANY CONDITIONS ENCOUNTERED
CONTRADICTORY TO THOSE SHOWN ON THE STRUCTURAL CONTRACT
DOCUMENTS.
8. THE GENERAL CONTRACTOR SHALL COORDINATE THE ARCHITECTURAL,
MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL WORK WITH THE
STRUCTURAL CONTRACT DOCUMENTS AND SHALL REPORT ANY SUSPECTED
DISCREPANCIES OR OMISSIONS TO THE ARCHITECT IMMEDIATELY.THE
STRUCTURAL CONTRACT DOCUMENTS DO NOT INCLUDE SHOP DRAWINGS,
VENDOR DRAWINGS NOR ANY MATERIAL PREPARED AND SUBMITTED BY THE
CONTRACTOR OR SUBCONTRACTORS.
9. REFERENCE TO STANDARD SPECIFICATIONS OF ANY TECHNICAL SOCIETY,
ORGANIZATION OR ASSOCIATION OR TO CODES OF LOCAL OR STATE
AUTHORITIES SHALL MEAN THE LATEST STANDARD, CODE,SPECIFICATION OR
TENTATIVE SPECIFICATION ADOPTED AND PUBLISHED AT THE DATE OF
TAKING BIDS UNLESS SPECIFICALLY STATED OTHERWISE.
10. FOR DIMENSIONS NOT SHOWN ON THE STRUCTURAL CONTRACT
DOCUMENTS, SEE THE ARCHITECTURAL DRAWINGS.THE CONTRACTOR SHALL
REVIEW THE STRUCTURAL DRAWINGS FOR SECTIONS AND DETAILS THAT ARE
LABELED AS "TYPICAL" AND ARE NOT NECESSARILY REFERENCED ON THE
STRUCTURAL PLANS WHERE THEY APPLY.
EXISTING CONSTRUCTION
1. BEFORE FABRICATION AND ERECTION OF ANY MATERIALS, FIELD VERIFY
ALL EXISTING ELEVATIONS, DIMENSIONS, AND CONDITIONS AS SHOWN ON
THE DRAWINGS AND REPORT ANY DISCREPANICIES TO THE ARCHITECT &
ENGINEER OF RECORD AT ONCE.
STEEL FRAMING NOTES
8. ALL STEEL MEMBERS EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALV.
GALVANIZED OR PAINTED WITH TNEMEC EPOXY SYSTEM OR SIMILAR SYSTEM
MEETING THE REQUIREMENTS FOR PAINTING STRUCTURAL STEEL IN THE
PROJECT SPECIFICATIONS. ALL OTHER STEEL MEMBERS SHALL BE FURNISHED
WITH A SHOP COAT OF TNEMEC RED OR GRAY OXIDE PRIMER OR SIMILAR
SYSTEM MEETING THE REQUIREMENTS FOR PAINTING STRUCTURAL STEEL IN
THE PROJECT SPECIFICATIONS. ALL PRIMERS SHALL BE COMPATIBLE WITH TOP
COATINGS SPECIFIED.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INCLUDING THE
COSTS FOR ALL MISCELLANEOUS STEEL IN THEIR BID REGARDLESS OF
WHETHER OR NOT THOSE ITEMS ARE INDICATED ON THE STRUCTURAL
DRAWINGS. THESE COSTS SHALL INCLUDE, BUT ARE NOT LIMITED TO,
MISCELLANEOUS STEEL ITEMS SHOWN ON ARCHITECTURAL, CIVIL,
MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS.
9. FIELD CUTTING, DRILLING, OR OTHER MODIFICATION OF STRUCTURAL STEEL
COMPONENTS IS NOT PERMITTED WITHOUT WRITTEN APPROVAL OF THE
STRUCTURAL ENGINEER OF RECORD. WHERE BEAM PENETRATIONS
CANNOT BE AVOIDED OR WHERE CUTTING IS REQUIRED, THE CONTRACTOR
SHALL SUBMIT, TO THE STRUCTURAL ENGINEER OF RECORD, ALL
PERTINENT INFORMATION INCLUDING PENETRATION SHAPE, SIZE,
LOCATION, AND METHOD OF CUTTING THE OPENINGS.
2. ALL STRUCTURAL STEEL HSS SQUARE/RECT SECTIONS SHALL BE ASTM A500,
GRADE B (Fy=46 ksi). ALL STRUCTURAL STEEL WIDE FLANGE SHALL BE ASTM
A992 GRADE 50. CHANNEL SHAPES AND ALL OTHER MISCELLANEOUS STEEL
SHALL BE ASTM A36 OR A572. ALL STRUCTURAL STEEL HSS ROUND SHALL BE
ASTM A500, GRADE B (Fy=42 ksi). ALL BASE PLATES SHALL BE ASTM A572-50.
3. ALL STRUCTURAL BOLTS CONNECTING STRUCTURAL STEEL SHALL BE ASTM
A325 TYPE 1 WITH THREADS ALLOWED IN THE SHEAR PLANE, EXCEPT
ANCHOR BOLTS SHALL BE ASTM F1554 GR55, MUST MEET S1 WELDABILITY
REQUIREMENT OR GR36 AS NOTED.
4. WELD ELECTRODES SHALL BE E70XX.
1. UNLESS SPECIFICALLY NOTED OTHERWISE, FABRICATION AND ERECTION OF
STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH AISC SPECIFICATIONS,
LATEST EDITION.
6. UNLESS DETAILED OTHERWISE, ALL SHOP CONNECTIONS SHALL BE WELDED.
UNLESS DETAILED OTHERWISE, ALL FIELD CONNECTIONS SHALL BE MADE
USING 3/4"Ø, AND 1"Ø WHERE INDICATED, ASTM A325-N (OR ASTM F1852)
HIGH STRENGTH BOLTS ("N" INDICATES BEARING TYPE WITH THREADS
INCLUDED IN SHEAR PLANE). WASHERS SHALL BE INSTALLED UNDER NUTS
WHEN REQUIRED BY THE SPECIFICATIONS OF STRUCTURAL JOINTS.
7. WHERE FIELD AND SHOP WELDS ARE INDICATED ON THE DRAWINGS,
THEY SHALL BE THE SIZE AND TYPE NOTED. ALL WELDING OF
STRUCTURAL STEEL SHALL BE DONE IN ACCORDANCE WITH THE LATEST
EDITION OF AWS D1.1 CORRESPONDING TO THE AISC SPECIFICATION
USED AND ALL WELDS INCLUDING FIELD WELDS SHALL BE MADE BY
CERTIFIED WELDERS USING E70XX ELECTRODES.
5. UNLESS DETAILED OTHERWISE OR REACTIONS ARE INDICATED, BEAM
CONNECTIONS SHALL BE SELECTED TO SUPPORT 70% THE TOTAL UNIFORM
LOAD CAPICITY SHOWN IN THE "ALLOWABLE UNIFORM LOAD TABLES" IN PART 2
OF THE AISC STEEL CONSTRUCTION MANUAL, LATEST EDITION, FOR THE GIVEN
BEAM SIZE, SPAN, AND STEEL SPECIFICATION OR FOR THE BEAM REACTION
SHOWN ON THE DRAWINGS, WHICHEVER IS GREATER. THE MINIMUM BEAM
CONNECTION SHALL NOT BE SMALLER THAN THOSE LISTED IN TABLES 10-1 &
10-2 OF THE AISC STEEL CONSTRUCTION MANUAL, LATEST EDITION FOR THE
GIVEN BEAM DEPTH, BOLT DIAMETER, AND WELD SEPCIFICATION.
B. MASONRY ANCHORS
I. ANCHORAGE TO SOLID-GROUTED CONCRETE MASONRY
- MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED
FOR USE IN ACCORDANCE WITH ICC-ES AC01 OR AC106.
- ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED
FOR USE IN ACCORDANCE WITH ICC-ES AC58.
II. ANCHORAGE TO HOLLOW CONCRETE MASONRY/UNREINFORCED
CLAY BRICK MASONRY
- MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND
QUALIFIED IN ACCORDANCE WITH ICC-ES AC106
- ADHESIVE ANCHORS WITH SCREEN TUBES SHALL BE TESTED
AND QUALIFIED IN ACCORDANCE WITH ICC-ES AC58 OR AC60, AS
APPROPRIATE.
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C :\0
R ev it
Lo ca ls \2
9\
-1
8-
S
T R
C R
V T
_k br id ge s4
M K
9D .r vt 2/
/2
8:
:1
A M
S001
STRUCTURAL GENERAL NOTES
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811 www.johnsondanforth.com
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 KB LB
0.1
1.1
2.0
2.1
3.0
3.1
4.0
4.1
5.0
5.1
6.0
6.1
7.0
7.1
8.0
F2
S103
C 1/
S
1'-0" (TYP)
2 2 2
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"
44 4
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C :\0
R ev it
Lo ca ls \2
9\
-1
8-
S
T R
C R
V T
_k br id ge s4
M K
9D .r vt 2/
/2
3:
:3
P M
S101
TUNNEL FLOOR PLANS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811 www.johnsondanforth.com
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 KB LB
1/8" = 1'-0"
C1 TUNNEL FLOOR PLAN @ GARAGE
SHEET NOTES:
1. SEE ARCH FOR DEMOLITION DRAWINGS AND NOTES.
2. SEE ARCH DRAWINGS FOR DIMENSIONS NOT SHOWN.
KEYED NOTES:
EXISTING TUNNEL WALL EXPANSION JOINT REPAIR. SEE ARCH FOR DETAILS.1
NEW STEEL PIPE SUPPORTS (TYP), SEE SECTIONS. LOCATE 1'-0" MINIMUM FROM
EXISTING PIPE SUPPORT FRAMES.
L4x4 (TYP) AT TOP OF VERTICAL PIPE SUPPORTS, SEE SECTIONS.3
EXISTING HOLLOW MASONRY WALL.4
GRID LOCATIONS INDICATE
THE EXISTING PIPE SUPPORT
LOCATIONS (TYP)
8.1
9.0
9.1
10.0
10.1
11.0
11.1
12.0
12.1
13.0
13.1
14.0
14.1
15.0
15.1
16.0
F8
S103
C 1/
S
2 2 2 2
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"
GRID LOCATIONS INDICATE
THE EXISTING PIPE SUPPORT
LOCATIONS (TYP)
F 6/
S
16.1
17.0
17.1
18.0
18.1
19.0
19.1
F 6/
S
2 2
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"
GRID LOCATIONS INDICATE
THE EXISTING PIPE SUPPORT
LOCATIONS (TYP)
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C :\0
R ev it
Lo ca ls \2
9\
-1
8-
S
T R
C R
V T
_k br id ge s4
M K
9D .r vt 2/
/2
3:
:4
P M
S102
TUNNEL FLOOR PLANS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811 www.johnsondanforth.com
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 KB LB
1/8" = 1'-0"
C1 TUNNEL FLOOR PLAN @ DRIVE
1/8" = 1'-0"
F6 TUNNEL FLOOR PLAN @ DRIVE
SHEET NOTES:
1. SEE ARCH FOR DEMOLITION DRAWINGS AND NOTES.
2. SEE ARCH DRAWINGS FOR DIMENSIONS NOT SHOWN.
KEYED NOTES:
EXISTING TUNNEL WALL EXPANSION JOINT REPAIR. SEE ARCH FOR DETAILS.1
NEW STEEL PIPE SUPPORTS (TYP), SEE SECTIONS. LOCATE 1'-0" MINIMUM FROM
EXISTING PIPE SUPPORT FRAMES.
L4x4 (TYP) AT TOP OF VERTICAL PIPE SUPPORTS, SEE SECTIONS.3
EXISTING HOLLOW MASONRY WALL.4
GARAGE FFE
0' - 0"
TUNNEL FFE
-11' - 4 1/2"
C6x8.2
C8x11.5
C8x11.5
C8x11.5
C8x11.5
C8x11.5
C8x11.5
L4x4x5/16 EXTEND
TO NEXT VERT
C6 BTWN EVERY
OTHER VERT C6;
SEE PLAN
EXISTING
CONCRETE
WALL
EXISTING
HOLLOW
CLAY BLOCK
NOTES:
1. PIPE SUPPORT DESIGNED FOR ONE (1) 12" DIA PIPE
SPANNING 10'-0" ON CENTER.
2. ALL STEEL TO BE HOT-DIPPED GALVANIZED.
3. PIPE HANGERS AND PIPE PEDESTALS TO DESIGNED AND
PROVIDED BY PIPE SUPPLIER / MECH CONTRACTOR.
B A
6"
3"
6"
CONCRETE PEDESTAL 6" x 12" REINF w/ #4 BAR & 2 - 1/2" DIA
F1554-GR36 THREADED RODS
EPOXY DWL INTO EXISTING
SLAB (TYP)
OR USE PRECAST BLOCK w/ PRE-DRILLED
HOLES EXTENSION & GROUT SOLID
FIELD VERIFY
2'-2" 1'-8"
FIELD VERIFY
2'-2"
F
IE
LD
V
E R
IF
Y
5' -1
0"
D5
S103
BA
TUNNEL ROOF
-3' - 4 1/2"
TUNNEL FFE
-11' - 4 1/2"
C6x8.2
C8x11.5
C8x11.5
C8x11.5
C8x11.5
C8x11.5
C8x11.5
B A
L4x4x5/16 x0'-6" w/ 2 - 1/2" DIA
EXPANSION
(2 3/8" MIN
EMBEDMENT)
EXISTING
CONCRETE
TUNNEL
F
IE
LD
V
E R
IF
Y
7' -0
FIELD VERIFY
2'-2" 1'-8"
FIELD VERIFY
2'-2"
A B
SECTION A
1 1/2" = 1'-0"
3"
SECTION B
1 1/2" = 1'-0"
1 1/2" 3"
1 1/2"
C6 VERT
C8 w/ 2 -1/2" DIA
A325 BOLTS
L4x4x5/16x0'-6" w/ 2 - 1/2 DIA
A325 BOLTS
C4
C8
L4x4x5/16x0'-6"
AT EXISTING CONCRETE WALL
PROVIDE 2 - 1/2 DIA HILTI KWIK
BOLT III EXPANSION ANCHORS (2
3/8" MIN EMBEDMENT) AT
CONCRETE WALL;
AT EXISTING HOLLLOW
CLAY BLOCK WALL - PROVIDE 2 -
1/2 DIA THREADED ROD ANCHORS
w/ HILITI HY70 ADHESIVE OR
APPROVAL EQUAL (4 1/2"
EMBEDMENT)
C6 VERT
SUPPORT
PL 1/2"
3/16
3" 3"
6"
1' -0
2"
1/
2"
1/
2"
1/ 2"
1/
2"
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C :\0
R ev it
Lo ca ls \2
9\
-1
8-
S
T R
C R
V T
_k br id ge s4
M K
9D .r vt 2/
/2
8:
:1
A M
S103
SECTIONS & DETAILS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811 www.johnsondanforth.com
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 KB LB
3/4" = 1'-0"
F2 TUNNEL SECTION @ GARAGE
3/4" = 1'-0"
F8 TUNNEL SECTION @ DRIVE
1 1/2" = 1'-0"
D5 BASE PLATE
DRAIN
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CONDENSATE PUMP DISCHARGE
X-D
X-CHR
X-CHS
X-CPD
CONDENSER WATER RETURNX-CWR
CONDENSER WATER SUPPLYX-CWS
HIGH PRESSURE CONDENSATE
HIGH PRESSURE STEAM
LOW PRESSURE CONDENSATE
LOW PRESSURE STEAM
HIGH PRESSURE GASX-HPG(XX)
X-HPC
X-HPS(XX)
X-LPC
X-LPS(XX)
SHT #
X0.0
EXISTING PIPING TO
BE REMOVED
MECHANICAL SYMBOLS AND ABBREVIATIONS
SYMBOLS INDICATED HERE AND NOT USED IN THE CONTRACT DOCUMENTS DO NOT APPLY TO THIS
PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED IN THE CONTRACT DOCUMENTS.
NAME
NOTE:
SYSTEM LABELS
PIPING SPECIALTIES
WATER PIPING CONNECTION
EXPANSION JOINT
DIRECTION OF FLOW
LINE CONTINUATION BREAK
DOUBLE
ELBOW DOWN
ELBOW UP
BOTTOM CONNECTION
(45° OR 90°)
TOP CONNECTION
(45° OR 90°)
EXISTING PIPING TO REMAIN
SINGLE
PIPING
BUTTERFLY VALVE
GATE VALVE
GLOBE VALVE
BALL VALVE
(XX)=DEFINES FAIL POSITION OR NORMAL POSITION
FC=FAIL CLOSED (CONTROL VALVE OR DAMPER)
FO=FAIL OPEN (CONTROL VALVE OR DAMPER)
NO=NORMALLY OPEN (CONTROL VALVE OR DAMPER)
NC=NORMALLY CLOSED (CONTROL VALVE OR DAMPER)
VALVES
GENERAL CONTRACTOR
GALLONS PER MINUTE
GC
GPM
OV OUTLET VELOCITY
SCHEDULE
PHASE
TOP
TOD
TOS
PSIG
PSIA
PCF
PSI
TSP
TOB
SCH
PH
PSF
EXISTINGX
WG
WC
TOP OF PIPE
TOP OF DUCT/TOP OF DECK
TOP OF SLAB
POUNDS PER SQUARE INCH GAUGE
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER CUBIC FOOT
POUNDS PER SQUARE INCH
WATER COLUMN
WATER GAUGE
TOTAL STATIC PRESSURE
TOP OF BEAM
POUNDS PER SQUARE FOOT
PC PLUMBING CONTRACTOR
FLR FLOOR
MEP
MBH
MC
NTS
OC ON CENTER
COP
COND
CENTER OF PIPE
CONDENSATE/CONDENSER
MECHANICAL, ELECTRICAL AND PIPING
NOT TO SCALE
THOUSANDS OF BTU PER HOUR
MECHANICAL CONTRACTOR
P PUMP
CONTROL PANEL
CONDENSATE PUMP/
STORAGE TANK/STEAM TRAP
WATER FILTER
CP
ST
WF
ABBREVIATIONS
V VALVE/VOLTS
(XX) = SYSTEM PRESSURE IN PSIG
DRAIN
CHILLED WATER RETURN
CHILLED WATER SUPPLY
HOT WATER RETURN
HOT WATER SUPPLY
CONDENSATE PUMP DISCHARGE
HIGH PRESSURE CONDENSATE
HIGH PRESSURE STEAM
LOW PRESSURE CONDENSATE
LOW PRESSURE STEAM
HIGH PRESSURE GASHPG(XX)
D
CHR
CHS
HWR
HWS
CPD
HPC
HPS(XX)
LPC
LPS(XX)
NEW CONNECTION TO EXISTING
REFERENCE SYMBOLS
EQUIPMENT NAME AND NUMBER
SHEET KEYNOTE NUMBER
REVISION NUMBER
CONSTRUCTION BULLETIN NUMBER
DETAIL REFERENCE TOP
DESIGNATES
DETAIL NUMBER BOTTOM
DESIGNATES SHEET NUMBER
SECTION REFERENCE TOP
DESIGNATES SECTION
NUMBER
BOTTOM DESIGNATES SHEET
NUMBER
GENERAL REFERENCE
DESIGNATES SHEET
NUMBER
DEMO TO THIS POINT
1. GENERAL NOTES APPLY TO ALL MECHANICAL SHEETS.
2. THE CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK
INCLUDED IN THE CONTRACT. DO NOT SCALE THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
COORDINATION.
3. THE MECHANICAL CONTRACTOR SHALL PROVIDE MEP COORDINATION DRAWINGS (PLANS AND SECTIONS) AT A SCALE OF NOT LESS THAN 1/4" = 1'0" TO ILLUSTRATE PROBOSED FINAL LOCATION AND COORDINATION OF ALL MECHANICAL.
4. FIELD CHANGES TO THE ROUTING OF PIPE 2" AND SMALLER AS SHOWN ON THE CONTRACTOR'S COORDINATION DRAWINGS INCLUDING CLEARANCE WILL BE ALLOWED AT THE DISCRETION OF THE OWNER'S CONSTRUCTION INSPECTOR.
5. THE MECHANICAL CONTRACTOR SHALL DETERMINE THE FINAL ELEVATION OF THE STRUCTURAL BEAMS AND IMBEDS THAT
ARE PROVIDED FOR THE PURPOSE OF SUPPORTING THE PIPES.
6. PROVIDE LOW POINT DRAINS AS REQUIRED TO COMPLETELY DRAIN ALL SYSTEMS AND HIGH POINT MANUAL AIR VENTS.
7. PROVIDE ALL UNIONS, BUSHINGS, AND/OR REDUCING INSERTS, ETC, NOT SHOWN ON THE DRAWINGS BUT REQUIRED FOR
INSTALLATION.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL FLUIDS CONTAINED WITHIN ALL PIPING, EQUIPMENT, AND TASKS. NO FLUIDS SHALL BE ALLOWED TO BE DISCHARGED TO SANITARY OR STORM LINES WITHOUT WRITTEN APPROVAL FROM THE OWNER'S CONSTRUCTION MANAGER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTAINING, HAULING, AND PROPERLY AND LEGALLY DISPOSING OF ALL REMOVED FLUIDS FROM THE SITE.
9. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIRMENTS.
GENERAL NOTES
CONDENSER WATER RETURNCWR
CONDENSER WATER SUPPLYCWS
(SMALLER THAN 4") (4" AND LARGER)
NEW EXISTING
REFER
X0.0
PCR PUMPED CONDENSATE RETURN
CHS CHILLED WATER SUPPLY
DOMESTIC COLD WATERDCW
PUMPED CONDENSATE RETURNPCR
DOMESTIC COLD WATERX-DCW
PUMPED CONDENSATE RETURNX-PCR
DCW DOMESTIC COLD WATER
DDC
EL
EC
ETR
EWT
EXISTING TO REMAIN
ELEVATION
DIRECT DIGITAL CONTROL
ENTERING WATER TEMPERATURE
ELECTRICAL CONTRACTOR
EXPANSION JOINTEJ
DCW DOMESTIC COLD WATER
TANKT
EXISTING PIPING TO
BE REMOVED
LINE CONTINUATION BREAK
DOUBLE
ELBOW DOWN
ELBOW UP
BOTTOM CONNECTION
(45° OR 90°)
TOP CONNECTION
(45° OR 90°)
EXISTING PIPING TO REMAIN
SINGLE
PIPING
(SMALLER THAN 4") (4" AND LARGER)
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:4
A
M
M000
MECHANICAL SYMBOLS &
ABBREVIATIONSJohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
2019.02.22 BB MAB
2.1 3.1 4.1 5.1 6.1 7.11.1
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
8.1
F3
M601
C3
M600
F1
M600
D6
M601
C7
M603
2" XPCR
6" XHPS
UP TO PLANT
UP TO PLANT
UP TO PLANT
UP TO PLANT
2" XHPS
10" XHPS
8" XPCR
12" XHPS
8" XDCW
8" XPCR
18" XCHS
SLIP EXPANSION
JOINTS
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
9 R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
EXISTING SLIP
EXPANSION JOINTS
4" XPCR
/M
4(TYP. FOR ALL)
4 (TYP. FOR ALL)
4(TYP. FOR ALL)
12" XHPS
8" XDCW
8" XPCR
10" XHPS
58" XPCR
4" XPCR
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:4
A
M
M101
MECHANICAL DEMOLITION PLAN
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
5 5 10 15 20
1/8" = 1'-0"
FEETSCALE
GENERAL NOTES
1. THIS DRAWING DOCUMENTS EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
PIPING, VALVES, AND SLIP JOINTS LOCATIONS AND
ARRANGEMENTS PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. REFER TO M600 FOR FURTHER INFORMATION.
4. REFER TO RENOVATION PLAN FOR FUTURE
WORK.
5. ONE STEAM LINE SHALL REMAIN ACTIVE DURING
INSULATION ABATEMENT, DEMOLITION, AND
RENOVATION PHASE ACTIVITIES.
1/8" = 1'-0"2
MECHANICAL TUNNEL FLOOR PLAN @ GARAGE - DEMOLITION
SHEET KEYED NOTES#
1. REMOVE EXISTING INSULATION FROM EXISTING CHILLED WATER LINE.
2. EXTENT OF DEMOLITION OF EXISTING INSULATION SHALL NOT EXCEED
SPECIFIED POINT FOR ASSOCIATED SYSTEM.
3. REMOVE EXISTING EXPANSION JOINT ON EXISTING 10 INCH HIGH PRESSURE
STEAM PIPING FOR REPLACEMENT DURING RENOVATION PHASE.
4. REMOVE EXISTING PIPE SUPPORT/RESTRAINING AT STRUCTURAL SUPPORT
RACK FOR ALL EXISTING PIPING SUPPORTED BY RACK. MISCELLANEOUS
PIPING TO BE TEMPORARILY SUPPORTED DURINGREPLACEMENTS OF
STRUCTURAL SUPPORT MEMBERS.
5. REMOVE EXISTING INSULATION FROM EXISTING STEAM LINE.
6. REMOVE EXISTING INSULATION FROM EXISTING 8 INCH
PUMPEDCONDENSATE RETURN LINES (QTY. 2).
7. REMOVE EXISTING INSULATION ON 4 INCH CONDENSATE RETURN PIPING.
9.1
10.0
10.1
11.0
11.1
12.0
12.1
13.0
13.1
14.0
14.1
15.0
15.1
16.0
8.1
F6
M602
B8
M605
C1
M606
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
8" XPCR
EXISTING SLIP
EXPANSION JOINTS
EXISTING SLIP
EXPANSION JOINTS
/M
3(TYP. FOR ALL)
3(TYP. FOR ALL)
3 (TYP. FOR ALL)
16.0
16.1
17.0
17.1
18.0
18.1
19.0
19.1
D8
M605
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
12" XHPS
8" XDCW
10" XHPS 18" XCHS
R A
C K
3 (TYP. FOR ALL)
M
M
3 (TYP. FOR ALL)
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:4
A
M
M102
MECHANICAL DEMOLITION PLAN
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
1. THIS DRAWING DOCUMENTS EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
PIPING, VALVES, AND SLIP JOINTS LOCATIONS AND
ARRANGEMENTS PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. REFER TO M600 FOR FURTHER INFORMATION.
4. REFER TO RENOVATION PLAN FOR FUTURE
WORK.
5. ONE STEAM LINE SHALL REMAIN ACTIVE DURING
INSULATION ABATEMENT, DEMOLITION, AND
RENOVATION PHASE ACTIVITIES.
GENERAL NOTES
SHEET KEYED NOTES#
1. REMOVE EXISTING INSULATION FROM EXISTING CHILLED WATER
LINE.
2. REMOVE EXISTING 4 INCH STEAM LINE UP TO DISTRIBUTION
MAIN AND PROVIDE CAP AND NEW INSULATION.
3. REMOVE EXISTING PIPE SUPPORT/RESTRAINING AT
STRUCTURAL SUPPORT RACK FOR ALL EXISTING PIPING
SUPPORTED BY RACK. MISCELLANEIOUS PIPING TO BE
TEMPORARILY SUPPORTED DURING REPLACEMENT OF
STRUCTURAL MEMBERS.
4. REMOVE EXISTING INSULATION FROM EXISTING STEAM LINE.
5. REMOVE EXISTING INSULATION FROM 8 INCH CONDENSATE
RETURN LINES (QTY. 2).
1/8" = 1'-0"2
MECHANICAL TUNNEL FLOOR PLAN @ DRIVE - DEMOLITION
1/8" = 1'-0"1
MECHANICAL TUNNEL FLOOR PLAN @ DRIVE - CONT.
19.0
19.1
F8
M602
L6
M604
C2
M604
R A
C K
R A
C K
EXISTING
SUMP PUMP
4" XPCR
4" XCHR
8" XPCR
8" X
D C
W
4" XCHS
18" XCHS
" X
H
PS
18" XCHS
" X
C H
R
12" XHPS
4" XDCW
12" XHPS
3" XHPS
3" XHPS
EXISTING VALVE S-3
EXISTING VALVE S-1B
EXISTING GAS
REGULATOR
/M
3 (TYP. 4)
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M103
MECHANICAL SUB-BASEMENT
DEMOLITION PLANJohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/4" = 1'-0"1
MECHANICAL SUB-BASEMENT FLOOR PLAN - DEMOLITION
2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
1. THIS DRAWING DOCUMENTS EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
PIPING, VALVES, AND SLIP JOINTS LOCATIONS AND
ARRANGEMENTS PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. REFER TO M600 FOR FURTHER INFORMATION.
4. REFER TO RENOVATION PLAN FOR FUTURE
WORK.
5. ONE STEAM LINE SHALL REMAIN ACTIVE DURING
INSULATION ABATEMENT, DEMOLITION, AND
RENOVATION PHASE ACTIVITIES.
GENERAL NOTES
SHEET KEYED NOTES#
1. REMOVE EXISTING INSULATION FROM EXISTING CHILLED WATER
LINE.
2. REMOVE EXISTING INSULATION FROM EXISTING STEAM LINE.
3. REMOVE EXISTING PIPE SUPPORT/RESTRAINTS AT
STRUCTURAL SUPPORT RACK FOR ALL EXISTING PIPING
SUPPORTED BY RACK. MISCELLANEOUS PIPING TO BE
TEMPORARILY SUPPORTED DURING REPLACEMENTS OF
STRUCTURAL SUPPORT MEMBERS.
4. REMOVE EXISTING STEAM VALVE.
5. REMOVE EXISTING STEAM VALVE. CONTRACTOR TO REPLACE
PACKING DISC AND SEAT ON EXISTING STEAM VALVE AND
RETURN TO OWNER.
6. REMOVE EXISTING INSULATION FROM 8 INCH CONDENSATE
RETURN LINES (QTY. 2).
7. EXTENT OF DEMOLITION OF EXISTING INSULATION SHALL NOT
EXCEED SPECIFIED POINT FOR ASSOCIATED SYSTEM.
8.1
F3
M601
C3
M600
F1
M600
D6
M601
C7
M603
2" XPCR
6" XHPS
UP TO
PLANT
UP TO
PLANT
UP TO PLANT
UP TO PLANT
2" XHPS10" XHPS
8" XPCR
12" XHPS
8" XDCW
8" XPCR
18" XCHS
4" XPCR
EXISTING SLIP EXPANSION JOINTS
ON CONDENSATE RETURN PIPING
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
9 R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
EXISTING SLIP
EXPANSION JOINTS
ON STEAM PIPING
4" XPCR
/M
4 4
4 4 4
4 4 4
5 (TYP FOR ALL)
5 (TYP FOR ALL)
9 (TYP. 2)
(TYP. 2)
(TYP. 2)
(TYP. 2)
(TYP. 2) (TYP. 2) (TYP. 2)
(TYP. 2)
(TYP. 2)
(TYP. 2)
(TYP. 2)
(TYP. 2)
(TYP. 2)
8" XDCW
12" XHPS
5 (TYP FOR ALL)
18" XCHR
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M201
MECHANICAL RENOVATION PLAN
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/8" = 1'-0"2
MECHANICAL TUNNEL FLOOR PLAN @ GARAGE - RENOVATION
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD CONDITIONS BASED
ON ORIGINAL DRAWINGS AND LIMITED FIELD OBSERVATIONS.
FIELD VERIFY EQUIPMENT LOCATIONS AND ARRANGEMENT
PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND SYMBOL
INFORMATION.
3. REFERENCE M600 FOR FURTHER DEMOLITION AND RENOVATION
SCOPE INFORMATION.
4. MISCELLANEOUS PIPING TO BE SUPPORTED DURING
CONSTRUCTION.
5. ONE STEAM LINE SHALL REMAIN ACTIVE DURING INSULATION
ABATEMENT, DEMOLITION, AND RENOVATION PHASE ACTIVITIES.
6. WITHIN 5' 0" OF NEW WORK, CONTRACTOR SHALL MAINTAIN
AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS BELOW
DEW POINT ON CHILLED WATER PIPING PRIOR TO INSTALLING
NEW CHILLED WATER PIPING INSULATION.
SHEET KEYED NOTES#
1. PROVIDE NEW INSULATION FOR 10 INCH AND 12 INCH EXISTING STEAM
LINES.
2. REPLACE EXISTING EXPANSION JOINT WITH NEW SLIP TYPE
EXPANSION JOINT ON 10 INCH HIGH PRESSURE STEAM PIPING.
3. PROVIDE NEW MECHANICAL PIPE SUPPORT FOR EXISTING STEAM
PIPING AT STRUCTURAL SUPPORT RACK . ATTACH TO NEW
STRUCTURAL MEMBER.
4. PROVIDE NEW MECHANICAL ADJUSTABLE PIPE SLIDING GUIDE FOR
EXISTING STEAM PIPING AS SPECIFIED AND ATTACH TO NEW
STRUCTURAL MEMBER.
5. PROVIDE NEW MECHANICAL PIPE SUPPORTS FOR ALL EXISTING
DOMESTIC COLD WATER AND CHILLED WATER PIPING. ATTACH TO NEW
STRUCTURAL MEMBER.
6. PROVIDE NEW MECHANICAL ADJUSTABLE PIPE SLIDING GUIDE FOR
EXISTING CONDENSATE RETURN PIPING AS SPECIFIED AND ATTACH TO
NEW STRUCTURAL MEMBER.
7. PROVIDE NEW MECHANICAL PIPE ANCHOR FOR EXISTING 8 INCH
CONDENSATE RETURN PIPING (QTY. 2) AND 10 INCH STEAM PIPING AS
SPECIFIED AND ATTACH TO NEW STRUCTURAL MEMBER.
8. PROVIDE NEW MECHANICAL PIPE ANCHOR FOR EXISTING 12 INCH
STEAM LINE AS SPECIFIED AND ATTACH TO NEW STRUCTURAL MEMBER.
9. PROVIDE NEW MECHANICAL PIPE SUPPORT FOR EXISTING
CONDENSATE RETURN AT STRUCTURAL SUPPORT RACK . ATTACH TO
NEW STRUCTURAL MEMBER.
10. PROVIDE NEW INSULATION FOR 4 INCH EXISTING CONDENSATE
RETURN LINE. EXTENT OF RENOVATION TO BE BETWEEN ELBOWS.
11. PROVIDE NEW INSULATION FOR 8 INCH CONDENSATE RETURN LINES
(QTY.2).
12. PROVIDE NEW INSULATION FOR CHILLED WATER LINE.
13. NEW INSULATION SHALL NOT EXCEED SPECIFIED POINT FOR
ASSOCIATED SYSTEM FOR EXTENT OF RENOVATION.
10.0
10.1
11.0
11.1
12.0
12.1
13.0
13.1
14.0
14.1
15.0
15.1
16.0
8.1
F6
M602
B8
M605
C1
M606
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
8" XPCR
EXISTING SLIP EXPANSION JOINTS ON
EXISTING STEAM AND CONDENSATE
RETURN PIPING.
EXISTING SLIP
EXPANSION JOINTS ON
EXISTING STEAM PIPE
/M
3 3 3 3 3
3 3 3 3
2 2
4 (TYP. FOR ALL)
(TYP. FOR ALL)
88(TYP. 2)
(TYP. 2)
(TYP. 2)
(TYP. 2) (TYP. 2) (TYP. 2) (TYP. 2)
(TYP. 2)
(TYP. 2) (TYP. 2)
(TYP. 2)
16.0
16.1
17.0
17.1
18.0
18.1
19.0
D8
M605
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
R A
C K
12" XHPS
8" XDCW
10" XHPS 18" XCHS
/M
2 2
2 2
(TYP. FOR ALL)
88 (TYP. 2) (TYP. 2)
(TYP. 2)
/M
18" CHR
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M202
MECHANICAL RENOVATION PLAN
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/8" = 1'-0"2
MECHANICAL TUNNEL FLOOR PLAN @ DRIVE - RENOVATION
1/8" = 1'-0"1
MECHANICAL TUNNEL FLOOR PLAN @ DRIVE - RENOVATION CONT.
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD CONDITIONS BASED
ON ORIGINAL DRAWINGS AND LIMITED FIELD OBSERVATIONS.
FIELD VERIFY EQUIPMENT LOCATIONS AND ARRANGEMENT
PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND SYMBOL
INFORMATION.
3. REFERENCE M600 FOR FURTHER DEMOLITION AND RENOVATION
SCOPE INFORMATION.
4. MISCELLANEOUS PIPING TO BE SUPPORTED DURING
CONSTRUCTION.
5. ONE STEAM LINE SHALL REMAIN ACTIVE DURING INSULATION
ABATEMENT, DEMOLITION, AND RENOVATION PHASE ACTIVITIES.
6. WITHIN 5' 0" OF NEW WORK, CONTRACTOR SHALL MAINTAIN
AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS BELOW
DEW POINT ON CHILLED WATER PIPING PRIOR TO INSTALLING
NEW CHILLED WATER PIPING INSULATION.
SHEET KEYED NOTES#
1. PROVIDE NEW INSULATION FOR 10 INCH AND 12 INCH EXISTING STEAM
LINES.
2. PROVIDE NEW MECHANICAL PIPE SUPPORT FOR EXISTING STEAM PIPING
AT STRUCTURAL SUPPORT RACK . ATTACH TO NEW STRUCTURAL
MEMBER.
3. PROVIDE NEW MECHANICAL ADJUSTABLE PIPE SLIDING GUIDE FOR
EXISTING STEAM PIPING AS SPECIFIED AND ATTACH TO NEW
STRUCTURAL MEMBER.
4. PROVIDE NEW MECHANICAL PIPE SUPPORTS FOR ALL EXISTING
DOMESTIC COLD WATER AND CHILLED WATER PIPING. ATTACH TO NEW
STRUCTURAL MEMBER.
5. PROVIDE NEW MECHANICAL ADJUSTABLE PIPE SLIDING GUIDE FOR
EXISTING CONDENSATE RETURN PIPING AS SPECIFIED AND ATTACH TO
NEW STRUCTURAL MEMBER.
6. PROVIDE NEW MECHANICAL PIPE ANCHOR FOR EXISTING 8 INCH
CONDENSATE RETURN PIPING (QTY. 2) AND 10 INCH STEAM PIPING AS
SPECIFIED AND ATTACH TO NEW STRUCTURAL MEMBER.
7. PROVIDE NEW MECHANICAL PIPE ANCHOR FOR EXISTING 12 INCH STEAM
LINE AS SPECIFIED AND ATTACH TO NEW STRUCTURAL MEMBER.
8. PROVIDE NEW MECHANICAL PIPE SUPPORT FOR EXISTING CONDENSATE
RETURN PIPING AT STRUCTURAL SUPPORT RACK . ATTACH TO NEW
STRUCTURAL MEMBER.
9. PROVIDE NEW INSULATION FOR 8 INCH CONDENSATE RETURN LINES
(QTY.2).
10. PROVIDE NEW INSULATION FOR CHILLED WATER LINE.
19.0
F8
M602
L6
M604
C2
M604
R A
C K
R A
C K
EXISTING
SUMP PUMP
4" XPCR
4" XCHR
8" XPCR
8" X
D C
W
M .0
4" XCHS10" XHPS18" XCHS
" X
H
PS
" X
C H
S
" X C
H R
12" XHPS
4" XDCW
12" XHPS
3" XHPS
3" XHPS
EXISTING VALVE S-3
EXISTING VALVE S-1B
EXISTING GAS
REGULATOR
D /M
8" XPCR
8" DCW 18" XCHR
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M203
MECHANICAL SUB-BASEMENT
RENOVATION PLANJohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/4" = 1'-0"1
MECHANICAL SUB-BASEMENT FLOOR PLAN - RENOVATION
1. THIS DRAWING DOCUMENTS EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
PIPING, VALVES, AND SLIP JOINT LOCATIONS AND
ARRANGEMENTS PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. REFERENCE M600 FOR FURTHER DEMOLITION
AND RENOVATION SCOPE INFORMATION.
4. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
5. ONE STEAM LINE SHALL REMAIN ACTIVE DURING
INSULATION ABATEMENT, DEMOLITION, AND
RENOVATION PHASE ACTIVITIES.
6. WITHIN 5' 0" OF NEW WORK, CONTRACTOR SHALL
MAINTAIN AMBIENT TEMPERATURE AND HUMIDITY
CONDITIONS BELOW DEW POINT ON CHILLED
WATER PIPING PRIOR TO INSTALLING NEW
CHILLED WATER PIPING INSULATION.
GENERAL NOTES SHEET KEYED NOTES#
1. PROVIDE NEW INSULATION ON EXISTING 10 INCH AND 12 INCH
STEAM LINE.
2. PROVIDE NEW MECHANICAL PIPE SUPPORT FOR EXISTING
STEAM PIPING. ATTACH TO NEW STRUCTURAL MEMBER.
3. PROVIDE NEW MECHANICAL PIPE SUPPORT FOR EXISTING
CHILLED WATER LINE. ATTACH TO NEW STRUCTURAL MEMBER.
4. PROVIDE NEW STEAM VALVE ON 10 INCH STEAM LINE.
5. PROVIDE NEW STEAM VALVE ON 12 INCH STEAM LINE.
6. PROVIDE NEW INSULATION ON CHILLED WATER LINE
7. PROVIDE NEW INSULATION ON 8 INCH PUMPED CONDENSATE
LINES (QTY. 2).
8. NEW INSULATION SHALL NOT EXCEED SPECIFIED POINT FOR
ASSOCIATED SYSTEM FOR EXTENT OF RENOVATION.
TUNNEL FFE
TUNNEL ROOF
1" XHPS
1" XHPS
8" XDCW
1" XHPS1" XHPS
10" XHPS
8" XPCR
8" XPCR
12" XHPS
EXISTING VALVE
EXISTING
VALVE
EXISTING VALVE
4" XPCR
1 2
5(TYP.)
GARAGE FFE
TUNNEL FFE
TUNNEL ROOF
8" XDCW
1" XD1" XD
12" XHPS
10" XHPS
8" XPCR
4" XPCR
8" XDCW
DOWN FROM CUP DOWN FROM CUP
10" XHPS
8" XPCR
12" XHPS
5(TYP.)
4" XPCR1
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:4
A
M
M600
MECHANICAL SECTIONS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/2" = 1'-0"C3 C3
1/2" = 1'-0"F1 F1
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGEMENT
PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
1 1 2 3 4 5
1/2" = 1'-0"
FEETSCALE
SHEET KEYED NOTES#
1. DEMOLISH EXISTING INSULATION AND PROVIDE
NEW INSULATION FOR EXISTING PIPING.
2. PROTECT EXISTING INSULATION FROM DAMAGE.
INSULATION SHALL REMAIN ON EXISTING PIPING.
3. PROTECT IN PLACE EXISTING 12.47 KV
CONDUCTORS DURING INSULATION
REPLACEMENT. COORDINATE WITH DIVISION 26.
4. REPLACE EXISTING MECHANICAL PIPE SUPPORT
WITH NEW PIPE SUPPORT.
5. ALL MISCELLANEOUS PIPING AND CONDUIT TO BE
TEMPORARILY SUPPORTED DURING
REPLACEMENT OF EXISTING SUPPORTS.
TUNNEL ROOF
8" XDCW
2" X
PC
R
6" XHPS
10" XHPS
8" XPCR
8" XPCR
12" XHPS
EXISTING LIGHT FIXTURE
EXISTING
VALVE
PIPE EXITING
TUNNEL AT THIS
POINT.
EXISTING CONDUIT
4 5 (TYP.)
TUNNEL FFE
TUNNEL ROOF
4" XPCR
10" XHPS
8" XPCR
8" XPCR
18" XCHS 18" XCHR
12" XHPS
2" X
H
PS
2" X
H
PS
8" XDCW
5(TYP.)
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M601
MECHANICAL SECTIONS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/2" = 1'-0"1 F3
1/2" = 1'-0"2 D6
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGEMENT
PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
SHEET KEYED NOTES#
1. DEMOLISH EXISTING INSULATION AND PROVIDE
NEW INSULATION ON EXISTING PIPING.
2. PROTECT EXISTING INSULATION FROM DAMAGE.
INSULATION SHALL REMAIN ON EXISTING PIPING.
3. PROTECT IN PLACE EXISTING 12.47 KV
CONDUCTORS DURING INSULATION
REPLACEMENT. COORDINATE WITH DIVISION 26.
4. REPLACE EXISTING MECHANICAL PIPE SUPPORT
WITH NEW PIPE SUPPORT. REFERENCE M201 AND
M202 FOR SPECIFIED LOCATIONS OF PIPE
SUPPORT, RESTRAINING GUIDE AND PIPE
ANCHOR LOCATIONS.
5. MISCELLANEOUS CONDUIT SHOWN FOR
INFORMATION ONLY.
8" XDCW
18" XCHR
18" XCHS
8" XPCR
8" XPCR
10" XHPS 12" XHPS
EXISTING LIGHT
FIXTURE
(TYP.)
3(TYP. 4)
TUNNEL FFE
TUNNEL ROOF
18" XCHS 18" XCHR
8" XDCW8" XPCR
12" XHPS10" XHPS
8" XPCR
15(TYP.)
(TYP. 4)
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:2
:2
A
M
M602
MECHANICAL SECTIONS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/2" = 1'-0"2 F8
1/2" = 1'-0"1 F6
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGEMENT
PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
SHEET KEYED NOTES#
1. DEMOLISH EXISTING INSULATION AND PROVIDE
NEW INSULATION ON EXISTING PIPING.
2. PROTECT EXISTING INSULATION FROM DAMAGE.
INSULATION SHALL REMAIN ON EXISTING PIPING.
3. PROTECT IN PLACE EXISTING 12.47 KV
CONDUCTORS DURING INSULATION
REPLACEMENT. COORDINATE WITH DIVISION 26.
4. REPLACE EXISTING MECHANICAL PIPE SUPPORT
WITH NEW PIPE SUPPORT. REFERENCE M201 AND
M202 FOR SPECIFIED LOCATIONS OF PIPE
SUPPORT, RESTRAINING GUIDE AND PIPE
ANCHOR LOCATIONS.
5. MISCELLANEOUS CONDUIT SHOWN FOR
INFORMATION ONLY.
2.1 1.1 1.02.02.1 1.1 1.02.0
TUNNEL FFE
TUNNEL ROOF
F3
M601
C3
M600
F1
M600
D6
M601
10" XHPS
8" XPCR
8" XPCR
6" XHPS
2" XPCR
1" XHPS
1" XD
DOWN FROM CUP
4" PCR
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M603
MECHANICAL SECTIONS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/2" = 1'-0"C7 C7
1 1 2 3 4 5
1/2" = 1'-0"
FEETSCALE
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGMENT
PRIOR TO CONSTRUCTION.
2. REFRENCE M000 FOR ABBREVIATION AND SYMBOL
INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
4. ONE STEAM LINE SHALL REMAIN ACTIVE DURING
INSULATION ABATEMENT, DEMOLITION, AND
RENOVATION PHASE ACTIVITIES.
5. WITHIN 5' 0" OF NEW WORK, CONTRACTOR SHALL
MAINTAIN AMBIENT TEMPERATURE AND HUMIDITY
CONDITIONS BELOW DEW POINT ON CHILLED
WATER PIPING PRIOR TO INSTALLING NEW
CHILLED WATER PIPING INSULATION.
SHEET KEYED NOTES#
1. DEMOLISH EXISTING INSULATION AND PROVIDE
NEW INSULATION ON EXISTING PIPING.
2. EXTENT OF REPLACEMENT OF EXISTING
INSULATION SHALL NOT GO BEYOND SPECFIED
POINT FOR ASSOCIATED SYSTEM.
8" XPCR
4" XCHR
4" X
C H
R
10" XHPS 12" XHPS
EXISTING SUMP PUMP
C2
M604
EXISTING GAS
REGULATOR
EXISTING
STEAM
VALVE
18" XCHS
8" PCR
8" PCR
12" XHPS
TUNNEL FFE
TUNNEL ROOF
L6
M604
8" PCR
12" XHPS
18" XCHR
8" XPCR
8" XPCR
10" XHPS
8" DCW
18" XCHS
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M604
MECHANICAL SECTIONS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/2" = 1'-0"L6 L6
1/2" = 1'-0"C2 C2
1 1 2 3 4 5
1/2" = 1'-0"
FEETSCALE
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGMENT
PRIOR TO CONSTRUCTION.
2. REFRENCE M000 FOR ABBREVIATION AND SYMBOL
INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
4. ONE STEAM LINE SHALL REMAIN ACTIVE DURING
INSULATION ABATEMENT, DEMOLITION, AND
RENOVATION PHASE ACTIVITIES.
5. WITHIN 5' 0" OF NEW WORK, CONTRACTOR SHALL
MAINTAIN AMBIENT TEMPERATURE AND HUMIDITY
CONDITIONS BELOW DEW POINT ON CHILLED
WATER PIPING PRIOR TO INSTALLING NEW
CHILLED WATER PIPING INSULATION.
SHEET KEYED NOTES#
1. DEMOLISH EXISTING INSULATION AND PROVIDE
NEW INSULATION ON EXISTING PIPING.
2. PROTECT EXISTING INSULATION FROM DAMAGE.
INSULATION SHALL REMAIN ON EXISTING PIPING.
3. REPLACE EXISTING STEAM VALVE ON 12 INCH LINE
AND PROVIDE NEW STEAM VALVE.
4. REMOVE EXISTING STEAM VALVE ON 10 INCH
STEAM LINE. EXISTING STEAM VALVE TO HAVE
VALVE PACKING DISK, SEAT, AND PIPING
FLANGES REPAIRED. RETURN REFURBISHED
STEAM VALVE TO OWNER.
5. EXTENT OF REPLACEMENT OF EXISTING
INSULATION SHALL NOT GO BEYOND SPECFIED
POINT FOR ASSOCIATED SYSTEM.
6. PROVIDE NEW STEAM VALVE ON 10 INCH LINE.
18" XCHR
8" XDCW
12" XHPS10" XHPS
8" XPCR
8" XPCR
18" XCHS
4"
4"
4"
EXISTING VALVE
EXISTING VALVE
ABANDONED
UNKNOWN
UTILITY
ABANDONED
UNKNOWN UTILITY5
(TYP.)
TUNNEL FFE
TUNNEL ROOF
18" XCHS
8" XDCW
18" XCHR
8" XPCR
8" XPCR
10" XHPS 12" XHPS
4 1
(TYP. 4) 3
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:1
A
M
M605
MECHANICAL SECTIONS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/2" = 1'-0"1 B8
1/2" = 1'-0"2 D8
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGEMENT
PRIOR TO CONSTRUCTION.
2. REFERENCE M000 FOR ABBREVIATION AND
SYMBOL INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
SHEET KEYED NOTES#
1. DEMOLISH EXISTING INSULATION AND PROVIDE
NEW INSULATION ON EXISTING PIPING.
2. PROTECT EXISTING INSULATION FROM DAMAGE.
INSULATION SHALL REMAIN ON EXISTING PIPING.
3. PROTECT IN PLACE EXISTING 12.47 KV
CONDUCTORS DURING INSULATION
REPLACEMENT. COORDINATE WITH DIVISION 26.
4. REPLACE EXISTING MECHANICAL PIPE SUPPORT
WITH NEW PIPE SUPPORT. REFERENCE M201 AND
M202 FOR SPECIFIED LOCATIONS OF PIPE
SUPPORT, RESTRAINING GUIDE AND PIPE
ANCHOR LOCATIONS.
5. MISCELLANEOUS CONDUIT SHOWN FOR
INFORMATION ONLY.
6. EXISTING PIPING TO BE DEMOLISHED TO CUP TAP.
PROVIDE CAP AND INSULATION.
11.0 11.111.0 11.1
TUNNEL ROOF
B8
M6054"
4"4"
12" XHPS
4"
8" XDCW
EXISTING
LIGHT
FIXTURE
DOWN FROM CUP
18" XCHS
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:2
:2
A
M
M606
MECHANICAL SECTIONS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
1/2" = 1'-0"1 C1
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGMENT
PRIOR TO CONSTRUCTION.
2. REFRENCE M000 FOR ABBREVIATION AND SYMBOL
INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
4. ONE STEAM LINE SHALL REMAIN ACTIVE DURING
INSULATION ABATEMENT, DEMOLITION, AND
RENOVATION PHASE ACTIVITIES.
5. WITHIN 5' 0" OF NEW WORK, CONTRACTOR SHALL
MAINTAIN AMBIENT TEMPERATURE AND HUMIDITY
CONDITIONS BELOW DEW POINT ON CHILLED
WATER PIPING PRIOR TO INSTALLING NEW
CHILLED WATER PIPING INSULATION.
SHEET KEYED NOTES#
1. DEMOLISH EXISTING INSULATION AND PROVIDE
NEW INSULATION ON EXISTING PIPING.
2. EXISTING PIPING TO BE DEMOLISHED UP TO CUP
TAP. PROVIDE CAP AND INSULATION.
4. PROTECT EXISTING INSULATION FROM DAMAGE.
INSULATION SHALL REMAIN ON EXISTING PIPING.
DOWN FROM CUP
10" XHPS
1" XHPS
6" XHPS
12" XHPS
1" XHPS
DOWN FROM CUP
10" XHPS
1" XHPS
6" XHPS
12" XHPS
1" XHPS 4
1 2 3 4 5 6 7 98 10
E
D
C
B
A
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
GULF COAST
VETERANS HEALTH
CARE SYSTEM
OVERTON BROOKS
VAMC
U.S. Department of Veterans Affairs
ARCHITECT OF RECORD:
A/E:
STAMP
MISSION CRITICAL
CONSTRUCTION DOCUMENTS
C U s e rs \K
T O
N -T
H A
T \D o c u m e n ts \R e v it
L o c a l C o p y \6
-1
-1
M E
P
M O
D E
L R
E V
IT
k to n -t h a t.
rv t
/2
/2
:1
:5
A
M
M607
MECHANICAL SCHEMATICS
JohnsonDanforth & Associates
2200 N. Rodney Parham Rd, Suite 210
Little Rock, AR 72212
501.404.4811
CORRECT TUNNEL
DISCREPANCIES
510 E. STONER AVENUE SHREVEPORT, LA 71101
667-18-101
B1 & B3
2019.02.22 BB MAB
STEAM SCHEMATIC DEMOLITION
STEAM SCHEMATIC RENNOVATION
SHEET KEYED NOTES#
GENERAL NOTES
1. THIS DRAWING DOCUMENT EXISTING FIELD
CONDITIONS BASED ON ORIGINAL DRAWINGS AND
LIMITED FIELD OBSERVATIONS. FIELD VERIFY
EQUIPMENT LOCATIONS AND ARRANGMENT
PRIOR TO CONSTRUCTION.
2. REFRENCE M000 FOR ABBREVIATION AND SYMBOL
INFORMATION.
3. MISCELLANEOUS PIPING TO BE SUPPORTED
DURING CONSTRUCTION.
1. DEMOLISH EXISTING STEAM VALVE ON 12 INCH LINE.
2. REMOVE EXISTING STEAM VALVE. EXISTING STEAM VALVE TO
BE REFURBISHED AND TURNED OVER TO THE VA.
3. DEMOLISH EXISTING THERMAL EXPANSION JOINT ON 10 INCH
LINE.
4. PROVIDE NEW STEAM VALVE ON 12 INCH LINE.
5. PROVIDE NEW STEAM VALVE ON 10 INCH LINE.
6. PROVIDE NEW THERMAL EXPANSION JOINT ON 10 INCH LINE.
SIZE
2-1/2"
3" 4"
5" 6" 8"
10"
12"
FORGED FLANGE
PIPE INTERNAL
GUIDE RING
OVERALL LENGTH
MULTI-PLY BELLOWS
DRAIN PLUG INTERNAL STOP
O.D.
OVERALL
LENGTH
51"
51" 51"
51" 51"
53"
53"
53"
MAX
PSIG
AXIAL
COMP.
8"
8" 8"
8" 8"
8"
8"
8"
AXIAL
EXT.
1-1/2"
1-1/2" 1-1/2"
1-1/2" 1-1/2"
1-1/2"
1-1/2"
1-1/2"
OUTSIDE
DIAMETER
6-5/8"
10-3/4"
12-3/4"
14-1/2"
14"
16"
6-5/8"
10-3/4"
EFFECTIVE
AREA IN. SQ.
WEIGHT
(LBS.)
CL
HL W/O
INSULATION
B A
7"
BS MAX. BOLT
DIAMETER FOR STEEL
ATTACHMENT
2 1/2" FOR 4" MIN.
BEAM FLANGE
4 1/2" FOR 6"
MIN. OR WIDER
BEAM FLANGE
W
INSULATION TO
SURROUND PIPE,
CLAMPS, AND
ADJUSTABLE
PEDESTAL
PIPE
SIZE
(IN)
PIPE
HEIGHT
CL
(IN)
OVERALL
HEIGHT
W/O
INSULATION
(HL)
MAXIMUM
INSULATION
THICKNESS LOWER
POSITION
(HL)
A
(IN)
B
(IN)
W
(IN)
8 9 13.5 2.5 10.5 12.5 11.75
ASG LOWER POSITION CL AND HL
ASG
PIPE
SIZE
(IN)
RATED
BASE
MOUNTED
PIPE LOAD
(LBS)
8 3050
1. INSTALL PIPE GUIDE PARALLEL WITH PIPE.
2. INSTALL DIELECTRIC SPACERS IN COPPER OR
BRASS WATER OR STEAM SYSTEMS UNDER
CLAMPS ON TOP AND BOTTOM.
3. ALL COMPONENTS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .