VAHPLB100_PHASE III_Delta 1 Drawings.pdf

PDF 424 KB Posted

Attached to
Y1DB--580-18-118 Pathology and Laboratory Renovation
Solicitation number
36C25620R0113
Issued by

About this file

This opportunity announcement is for a construction contract to renovate pathology and laboratory space at the Michael E. DeBakey VA Medical Center in Houston, Texas. The project involves demolishing and constructing approximately 12,400 square feet of space on the third floor of Building 100, including structural, architectural, mechanical, electrical, plumbing, communications, fire protection and interior finishes work. The period of performance is 810 calendar days from notice to proceed. The contract type is firm-fixed price and the estimated value is between $2-5 million. The NAICS code assigned is 236220 for commercial and institutional building construction with a small business size standard of $39.5 million in average annual receipts. The solicitation will be set aside 100% for Service-Disabled Veteran-Owned Small Businesses and require at least 15% of labor costs be spent on SDVOSB or veteran employees. The solicitation is expected to be released on July 21, 2020 as a request for proposals with a 90-day acceptance period. Bonds will be required from the contractor receiving award.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C G

CG

CG

CGCG

CG

CG

CG

CG

C G

CG

CG

CG

CG

CG

C G

CG

F

G

14 1315

H

FH-1

WS-1S

FR5

IC1

RF3

RF2

WS-4S

PM1

PM2

WS-5S

WS-6S

PR6

CF1

CF2

SC1

WS-3S

PR3

CF4

CF3

PR11

WS-2S

EL2

EL3

EL1

WS-8

PR4FX1

WS-2

WS-45

WS-33

WS-43

PR10

PR7PR8

WS-44

PR5

WS-N

WS-N

WS-46

WS-N

SC2

IS1

CF5

WS-52

PR26

PR27

WS-51

WS-50

PR28

PR29

RF15

IM2

RF20

MW2

MW1

RF21

RF22

SPECIAL

CHEMISTRY

LAB

3A-120

(E)

HAC

H5

(E) MT

3A-104

(E) FT

3A-102

ELEVATOR

P-16

ELEVATOR

P-13

(E)

BMS

STOR

3A-101

(E)

CORR

C3A-305

(E)

FIRE

STAIR

ST-13

SPECIMEN

COLLECTION

WAITING

3A-115

TOILET

3A-115C

TOILET

3A-115B

SPECIMEN

COLLECTION

3A-115A

BREAK

ROOM

3A-117

SPECIMEN

ACCESSIONING

3A-120A

STERILE

STORAGE

3A-119C

BULK

STORAGE

3A-119D

ELEVATOR

J28

ELEVATOR

J29

(E)

PASS

ELEV

LOBBY

C3A-303

SUPERVISOR

SPECIAL

CHEMISTRY

3A-120K

SUPERVISOR

IN-PATIENT

3A-120L

CORR.

C3A-100

120L

120K

120L

120K

115D 115A

115C

115B

115120

119D

119C

102B

102A

CORR

C3A-102

AE403

13SA3

15SA5

AE403

12SA2

AE403

14SA4

AE402

15SC5

AE402

12SC2

AE402

13SC3

AE402

11SC1

14SC4

AE402

16SC6

AE40116

AE40311

S A

AB3

AB2 PR2 PR1 AB1AB2

SC4

WS-N

WS-N

WS-N

WS-N

MC

RF1

BF6

RF16

WS-N

WS-N

BC3

AC1

IDS

WS-54

PR36

PWR2

SC3

WS-7S

RF25

AE400

AE40015

5' - 0"

AE401

15 14

AE401

AE401

8' - 1"

9'

0"

4'

- 0

" C

LR

5' - 0" CLR.

CLR.

5' - 0"

5' - 1"

2'

- 5

O

PP. S

ID

E

9" T

YP.

TYP.EQ

TYP.EQ

TYP.EQ

4'

- 0

4'

- 0

4'

- 1

0"

5'

- 0

" C

LR

TYP.1'

- 6

135.00°

CT6

CT1

CT1

CT5

CT9

CT2

CT6

CT2

CT2

CT2

CT2

CT6

CT6

CT5

CT2

CT2

CT4

OS1

OS1

OS1

OS2

OS1

OS2

8' - 4"

1' - 1"

EQ1

AE504

C

LR

2'

5'

- 9

/2

5' - 4"

18" M

IN.

AREA B

AREA A

AREA C

LEGEND:

(E) WALL (NON RATED)

(N) 1 HR FIRE RATED WALL

(E) 2 HR FIRE BARRIER

(E) 2 HR FIRE/ SMOKE BARRIER

(E) SMOKE BARRIER

(N) DOORS

NOT IN SCOPE

GENERAL NOTES:

1. SEE SHEET AE602 FOR SPECIALTY EQUIPMENT SCHEDULE

2. SEE SHEET AE603 FOR FURNITURE SYSTEM SCHEDULE,

OTHER EQUIPMENT AND ACCESSORIES SCHEDULE

3. FOR OTHER CASEWORK COMPONENTS, REFER TO CASEWORK

ELEVATIONS SHEET AE402, AE403 & AE404.

4. ALL INTERIOR WALLS SHALL EXTEND UP TO THE BOTTOM OF

3RD FLOOR INTERSTIAL FLOOR SLAB

5. ALL WALLS SHALL HAVE SOUND INSULATION

6. PROVIDE FIRE CAULKING TO ALL WALL AND CONCRETE FLOOR

PENETRATIONS

7. PROVIDE FIRE CAULKING ON ALL PENETRATIONS THROUGH

FIRE RATED WALLS

8. PAINT MATERIAL, COLOR AND MANUFACTURER SHALL MATCH

WITH THOSE CURRENTLY BEING USED BY VA MAINTENANCE

SECTION UNO.

9. ALL WALLS TO REMAIN WITHIN THE CONSTRUCTION AREA

SHALL BE TOUCHED UP AND REPAINTED

10. FURNITURE (CHAIRS, STOOLS & TABLES) WILL BE FURNISHED

BY GOVT. UNO.

11. ALL CABINETS ARE LOCKABLE

12. FOR SIGNAGE SEE SHEET GI003 AND WALL TYPES SEE SHEET

AE502

13. FOR EQUIPMENT & FURNITURE LOCATIONS SEE SHEET AE102

TO AE104. FOR INTERIOR FINISH SCHEDULE AND LEGEND SEE

SHEET AF601. FOR EQUIPMENT ANCHORAGE SEE 15/AE503 &

STRUCTURAL DWGS.

14. FOR FINISH PLAN SEE SHEET - AF101

15. FOR PIPE/CONDUIT/DUCT PENETRATION OF FIRE/SMOKE

BARRIERS SEE SHEET-AE505

16. ALL DIMENSIONS ARE FINISH TO FINISH, ADJUSTMENT TO

DIMENSIONS MAY BE REQUIRED TO FIT EQUIPMENT. VERIFY

EQUIPMENT DIMENSIONS W/ EQUIPMENT MANUFACTURER

17. FOR MORE INFO. ON DIMENSIONS SEE SHEET AE100

18. PROVIDE BEVELED OR A ROUND EDGES

19. SALVAGE ALL DOOR HARDWARE @ (E) DOORS WHICH ARE

REMOVED AND TURNOVER TO VA MEDICAL CENTER

20. ALL DEVICES TO BE (N) IN THE AREA OF WORK.

AT

T S

XETE FO

SA

R.

KALWANI

2 4 0 11

R

EG

IS

TE

RED ARCHITEC

T

03/31/20

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

315 Arden Ave, Suite 26 Glendale, CA 91203 t: 888.900.3823 www.schwabeng.com

PROJECT NO.:

RENOVATION OF PATHOLOGY

AND LABORATORY PHASE I

MICHAEL E. DEBAKEY VA MEDICAL CENTER

580-18-118

Building 100

Bi d

D oc um en ts S ub m itt al

Ph as e

I

March 06, 2020 SH/JARK

C :\U se rs

\s un al \D oc um en ts

\V A

H P

LB

0_ P

H A

S E

II

I_ su na lin i.r vt 8/

/2

:5

7:

A M

AE103

PHASE 1 ENLARGED PLAN AREA B

1/4" = 1'-0"

1 AREA B ENLARGED PLAN

PHASE 1

AREA C

, S

EE S

HEET A

E10

PHASE 1 - AREA A, SEE SHEET AE102

1" = 80'-0"

Key Plan - PHASE 3 - AREA B

KEYNOTES - NEW

NO. DESCRIPTION

1 RELOCATED (E) LOCKABLE BOX, WALL MOUNTED

2 (N) CASEWORK SOLID SURFACE COUNTERTOP WITH BASE

3 (E) PHLEBOTOMY CHAIR

4 (N) CLEAN SINK

5 (N) ACCESS CARD READER

6 CLOSE ACCESS TO DUMB WAITER OPENING. FINISH TO MATCH

ADJACENT SURFCE.

7 FINISH WALL TO MATCH EXISTING ADJACENT SURFACES. PROVIDE

SIGNAGE AS APPROVED BY VA. PROVIDE CRASHRAILS, HANDRAILS

AND CORNER GUARDS TO MATCH EXISTING.

8 FIRE EXTINGUISHER CABINET, SEE DETAIL 7/AE504

9 COSTUMIZE WALL PANEL ALONG (E) EXTERIOR WINDOW TO BE

BELOW WINDOW SILL

0 2' 4' 8'

N

Revisions: Date:

RESPONSE TO PRE-BID RFI 08/11/2020

DOOR SCHEDULE LEGEND

DOOR TYPE GENERAL NOTES

HM HOLLOW METAL

S SAFETY TEMPERED GLASS

STL STEEL

SCW SOLID CORE WOOD

HCW HOLLOW CORE WOOD

MTL METAL

A. REFER TO DEMOLITION PLANS FOR LOCATIONS OF

ALL DEMO AND REMOVED DOORS, DOOR FRAMES

AND HARDWARE, AS NOTED.

B. REFER TO FLOOR PLANS FOR LOCATIONS OF ALL

NEW DOORS, DOOR FRAMES AND HARDWARE.

C. SEALANT SHALL BE INSTALLED AT PERIMETER OF

ALL EXTERIOR DOOR FRAMES ON BOTH THE

EXTERIOR AND INTERIOR SIDE PROVIDING AN AIR,

WEATHER AND WATERTIGHT SEAL. INSTALL BACKER

RODS WHERE REQUIRED.

D. PAINT ALL NEW EXTERIOR HOLLOW METAL DOORS TO

MATCH EXISTING EXTERIOR DOORS. THE INTERIOR SIDE

SHALL BE PAINTED PER THE MATERIAL AND COLOR

LEGEND.

E. PAINT ALL DOOR FRAMES, REFERENCE THE MATERIAL

AND COLOR LEGEND FOR FINISH.

G. ALL DOORS NOT LISTED ARE EXISTING DOORS TO REMAIN

IN PLACE; REPAIR AND/OR REPLACE DAMAGED DOORS

WHERE REQUIRED.

H. REFER TO DOOR HARDWARE SPECIFICATION FOR

HARDWARE GROUPS FOR ALL NEW DOORS.

GLASS TYPE SCHEDULE

GT-1 1" INSULATED GLASS

GENERAL NOTES

1. ALL INTERIOR OFFICE DOORS SHALL BE SOLID CORE WOOD DOORS.

2. FOR DOORS TO OFFICES AND CONFERENCE ROOMS PROVIDE THE FOLLOWING:

a. DOOR SEALS, THRESHOLDS AND DOOR BOTTOM FOR PRIVACY

b. STC RATING TO MATCH THE WALLS (40 FOR PRIVATE OFFICES AND 45/50

FOR CONFERENCE ROOMS)

3. ALL DOORS ARE LOCKABLE

4. PER EDWARDS AFB INSTALLATION DESIGN STANDARDS:

a. EXTERIOR DOORS SHALL BE OPERABLE WITH NO MORE THAN 8 POUNDS

SUSTAINED PULL REQUIRED.

b. INTERIOR DOORS SHALL BE OPERABLE WITH NO MORE THAN 5 POUNDS

SUSTAINED PULL REQUIRED.

c. DOORS SHALL CONSIST OF THE FOLLOWING TYPES:

1. ALUMINUM DOORS SHALL BE 1 3/4 INCH THICK WITH 3 INCH WIDE

TOP RAIL AND VERTICAL STYLES, MEDIUM-BRONZE ANODIZED

FINISH, FACTORY APPLIED WEATHER STRIPPED, WITH SQUARE

GLAZING STOPS AND A 10 INCH HIGH BOTTOM RAIL AND

THRESHOLD.

2. STEEL DOORS SHALL BE FLUSH DESIGN, 1 3/4 INCH THICK WITH

STEEL GRID CORE OR STEEL STIFFENED CORE.

3. WOOD DOORS SHALL BE 1 3/4 INCH, SOLID CORE BIRCH HARDWOOD

VENEER FLUSH FACE DOORS. LOCKSETS SHALL BE APPROPRIATE

TO FUNCTION. ALL DOORS SHALL HAVE SILENCERS (EXCEPT WHERE

WEATHER-STRIPPING OCCURS). A 16 INCH HIGH MINIMUM MOP/KICK

PLATE SHALL BE PROVIDED AT THE KICK SIDE OF ALL WOOD

DOORS. DOOR HARDWARE AND LOCKSETS SHALL BE FACTORY

FINISHED. MEDIUM OR SATIN OR OIL-RUBBED ANODIZED BRONZED

FINISH FOR OFFICE SPACES AND CONFERENCE ROOMS. BRIGHT OR

SATIN NICKEL PLATED FINISH IS RECOMMENDED FOR BATHROOMS.

IN ALL CASES, HARDWARE AND LOCKSETS SHOULD MATCH THE

BUILDING DOOR AND WINDOW FRAMING SYSTEM COLOR.

STANDARD -SIZED DOOR LEVERS SHALL BE INSTALLED FOR

HANDICAPPED-ACCESS. HEAVY-DUTY LOCKS SHALL BE INSTALLED

ON HIGH-TRAFFIC DOORS AND MEDIUM-DUTY LOCKS FOR LIGHT

TRAFFIC DOORS.

4. DOOR HARDWARE PLANS AND SUBMITTALS SHALL BE

COORDINATED WITH AND APPROVED BY VA PRIOR TO PURCHASE

OR INSTALLATION. LOCKSETS SHALL BE COMPATIBLE WITH THE

EXISTING VA YALE MASTER KEYWAY SYSTEM. VA USES A 7-PIN

KEYWAY SYSTEM. ALL MATERIAL SUBMITTALS ARE REQUIRED FOR

APPROVAL.

5. FOR ROOMS W/ DOORS WITH STC RATING, PROVIDE WALLS W/ STC

50 OR MORE.

PER SCHED.

T

W1

SLIDING WINDOW

FLOOR FINISH

TOP OF TRANSACTION

COUNTER ALIGNED WITH

WINDOW SILL

A D

A A

C C

E S

S

IB

LE

2'

"P

E R

S C

H E

D

SEE AE101 AND AE504

FOR WALL TYPES

DOOR FRAME

SEE SCHED.

SEALANT EACH SIDE

(TYP.)

DOUBLE STUD

BOX HEADER

TYP. HEAD FRAMING

STEEL TRACK

DOOR SEAL

(WHERE PARTITION

TAG QUALIFIER "S"

IS INDICATED)

DOOR

SEE SCHED.

1/2" 1/2"

2" MIN

4" TYP FINISHED FACE OF

INTERSECTING PARTITION

SEE AE101 FOR WALL

TYPES

DOOR FRAME

SEE SCHED.

SEALANT EACH SIDE

(TYP.)

DOOR SEAL (WHERE

PARTITION TAG QUALIFIER

"S" IS INDICATED)

DOOR

SEE SCHED.

1/ 2"

1/ 2"

D1

SINGLE FLUSH

F.F.

D4

SLIDING

7'

3' - 0"

7'

3' - 7"

D2

DOUBLE DOOR UNEVEN

FLUSH

5' - 0"

7'

D3

SINGLE FLUSH

7'

3' - 0"

2' - 0" 3' - 0"

4"

6' - 10 1/2"

KICK

PLATE

FOR WALL TYPES, REFER

TO SHEET AE100 AND

DETAILS ON SHEET AE502

BATT INSULATION

5/8" GYP. BD. O/

METAL STUDS @ 16"

O.C. (BOTH SIDES)

METAL HEADER

ASSEMBLY

ALUMINUM FRAME,

SEE WINDOW

SCHEDULE

GLAZING PER SPECS.

2"

C

A U

LK

1/

4" S

H

IM

1/4" THICK CLEAR

SLIDING GLASS

WITH ALUMINUM

TRACK ASSEMBLY

ALUM. FRAME

CORNER BEAD

C

A U

LK

1/

4" S

H

IM

FOR WALL TYPES

REFER TO SHEET

AE100 AND DETAILS

ON SHEET AE502

5/8" THK. GWB O/

METAL STUDS @ 16"

O.C. (BOTH SIDES)

RESIN COUNTERTOP

F.F.

F1

P E

R S

C H

E D

U

LE

2"

2"

PER SCHEDULE

2"

F2

P E

R S

C H

E D

U

LE

2"

2"

PER SCHEDULE

2"

3rd FL 93' - 8"

8' - 0"

8'

1"

AE504

AE504

AE504

AE504

EQEQ

4' - 0"

8'

1"

T Y

P

1'

7' - 6"

8'

1"

EQEQ

T Y

P

6' - 6"

8'

1"

EQEQ

5' - 6"

8'

1"

EQEQ

T Y

P

6' - 0"

8'

1"

T Y

P

T Y

P

1'

7'

T Y

P

EQ EQ

(E) FLOOR SLAB

DOOR FRAME

BEYOND

TRANSITION STRIP

WHERE OCCURS

DOOR. SEE

DOOR SCHED.

AUTOMATIC DOOR

BOTTOM PER SPEC.

1/ 2"

M A

X

VINYL

COMPOSITION TILE

WHERE OCCURS

LUXURY VINYL

TILE- SEE FIN.

SCHED.

1/ 2"

M A

X

M O

R T

A R

3/

T

IL

E

5/

(E) FLOOR SLAB

DOOR FRAME

BEYOND

CERAMIC TILE FLOOR

DOOR-SEE

DOOR SCHED.

LUXURY VIYNL TILE-

SEE FIN. SCHED.

AUTOMATIC DOOR

BOTTOM PER SPEC.

TILE FLOOR PROFILE

TRANSITION STRIP

WHERE OCCURS

AT

T S

XETE FO

SA

R.

KALWANI

2 4 0 11

R

EG

IS

TE

RED ARCHITEC

T

03/31/20

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

315 Arden Ave, Suite 26 Glendale, CA 91203 t: 888.900.3823 www.schwabeng.com

PROJECT NO.:

RENOVATION OF PATHOLOGY

AND LABORATORY PHASE I

MICHAEL E. DEBAKEY VA MEDICAL CENTER

580-18-118

Building 100

Bi d

D oc um en ts S ub m itt al

Ph as e

I

March 06, 2020 SH/JARK

C :\U se rs

\s un al \D oc um en ts

\V A

H P

LB

0_ P

H A

S E

II

I_ su na lin i.r vt 8/

/2

:5

7:

A M

AE600

DOORS AND WINDOW SCHEDULE

DOOR SCHEDULE

DOOR

NUMBER WIDTH HEIGHT

DOOR

TYPE

DOOR

MAT'L

DOOR

FINISH

FRAME

TYPE

FRAME

MTR'L

FRAME

FINISH

HARDWARE

GROUP

FIRE

RATING

Sound Transmission Class (STC) DETAIL REMARKS Family

100 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-SH-10 1,2,3/AE600 PROVIDE PIV

READERS

Single-Flush

102A 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-SH-10 2-HR 1,2,3/AE600 PROVIDE PIV

READERS

Single-Flush

102B 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-SH-10 1-HR 1,2,3/AE600 PROVIDE PIV

READERS

Single-Flush

115 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) 501 2-HR 1,2,3/AE600 Single-Flush 115A 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) 401 1,2,3/AE600 Single-Flush 115B 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) 341 1,2,3/AE600 Single-Flush 115C 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) 341 1,2,3/AE600 Single-Flush

115D 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-4K 1,2,3/AE600 PROVIDE PIV

READERS

Single-Flush

117 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) 401 1,2,3/AE600 Single-Flush 118 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-4G 2-HR 1,2,3/AE600 Single-Flush 119 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-5G.1 2-HR 1,2,3/AE600 Single-Flush

119A 3' - 0" 6' - 6" FACTOR

Y

FACTORY FACTORY FACTORY 004 1-HR Freezer Cooler Swing Door

119B 3' - 0" 6' - 6" FACTOR

Y

FACTORY FACTORY FACTORY 001 1-HR Freezer Cooler Swing Door

119C 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-4K 1-HR 1,2,3/AE600 Single-Flush 119D 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-11A.SGL 1-HR 1,2,3/AE600 Single-Flush 120 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-SH-10 2-HR 1,2,3/AE600 PROVIDE PIV

READERS

Single-Flush

120D 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E 50 1,2,3/AE600 Single-Flush 120E 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E 50 1,2,3/AE600 Single-Flush 120F 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E 50 1,2,3/AE600 Single-Flush 120H 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E 50 1,2,3/AE600 Single-Flush 120I 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E 50 1,2,3/AE600 Single-Flush 120K 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E.1 50 1,2,3/AE600 Single-Flush 120L 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E.1 50 1,2,3/AE600 Single-Flush 121 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-4K 1,2,3/AE600 Single-Flush

121A 5' - 0" 7' - 0" D2 SCW SW F2 HM MATCH (E) HW-1K.PR 1,2,3/AE600 Door-Passage-Uneven-F lush

121B 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-3E 1,2,3/AE600 Single-Flush 121C 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) 401 1,2,3/AE600 Single-Flush 121D 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-11A.SGL 2-HR 1,2,3/AE600 Single-Flush 122A 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-5G.1 1,2,3/AE600 Single-Flush 209A 4' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HW-SH-10 1-HR 1,2,3/AE600 PROVIDE PIV

READERS

Single-Flush

215 3' - 0" 7' - 0" D1 SCW SW F1 HM MATCH (E) HM-4L 1,2,3/AE600 Single-Flush Grand total: 31

WINDOW SCHEDULE

WINDOW

TYPE

WINDOW

WIDTH

WINDOW

HEIGHT SILL HEIGHT

WINDOW

MATERIAL

WINDOW

FINISH DETAILS

FIRE

RATING REMARKS

W1 4' - 0" 4' - 2" ALUMINUM PAINTED 5,6/AE601 SLIDING PASS THRU WINDOW

3" = 1'-0"

DOOR HEAD DETAIL

3" = 1'-0"

DOOR JAMB DETAIL

1/4" = 1'-0"

DOOR TYPE LEGEND

3" = 1'-0"

PASS THRU WINDOW HEAD

(JAMB SIM.)

3" = 1'-0"

PASS THRU WINDOW SILL

1/4" = 1'-0"

DOOR FRAME LEGEND

1/4" = 1'-0" A A

1/4" = 1'-0" B B

1/4" = 1'-0" C C

1/4" = 1'-0" D D

1/4" = 1'-0" E E

1/4" = 1'-0" F F

3" = 1'-0"

VCT TO LVT- TS 2

3" = 1'-0"

CERAMIC TILE TO LVT- TS1

Revisions: Date:

RESPONSE TO PRE-BID RFI 08/11/2020

Sheets
AE103 - PHASE 1 ENLARGED PLAN AREA B
AE600 - DOORS AND WINDOW SCHEDULE

File details come from the government source that posted it. Updated .