087100r2 Door Hardware_08-07-2020.docx
DOCX document 45 KB Posted
- Solicitation number
- 36C25620R0113
About this file
This document provides specifications for door hardware required for the Renovation of Pathology and Laboratory, Phase III project at the Michael E. DeBakey VA Medical Center in Houston, Texas. Key hardware includes hinges, locks, exit devices, closers and other items. Finishes are generally satin chromium with some stainless steel. The specifications give requirements for hardware function, fire ratings, fasteners, keying, and installation. Hardware sets are scheduled for over 30 doors. Substitutions are allowed if equivalent in function, thickness and durability. Installers must be qualified and available for consultation. Adjustments will be inspected by a hardware consultant.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25620R0113 0002.docx | DOCX document | |
| 28 13 00 Physical Access Control Specification.pdf | ||
| VAHPLB100_PHASE III_Delta 1 Drawings.pdf | ||
| 580-18-118 Structural Sheets.pdf | ||
| Revised Proposal Submission Requirements 8-17-20.docx | DOCX document | |
| 36C25620R0113 0001.docx | DOCX document | |
| 580-18-118 Pneumatic Sheets.pdf | ||
| 085113 Aluminum Windows.doc | DOC document | |
| Egress Plan.pdf | ||
| 580-18-118 Project Statement of Work.docx | DOCX document | |
| 36C25620R0113_1.docx | DOCX document | |
| SF24 BID BOND.pdf | ||
| 580-18-118 Project Drawings - Dated 3-6-2020 - Part III.pdf | ||
| 580-18-118 Project Drawings - Dated 3-6-2020 - Part II.pdf | ||
| Site Visit Instructions for Project 580-18-118.docx | DOCX document | |
| DOL Wage Determinations TX20200253 02-14-2020.pdf | ||
| 580-18-118 Project Specifications.pdf | ||
| 580-18-118 Project Drawings - Dated 3-6-2020 - Part I.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Michael E. DeBakey VA Medical Center VA Project No: 580-18-118
| Network Contracting Office 16 |
| Renovation of Pathology and Laboratory, Phase III |
SECTION 08 71 00
DOOR HARDWARE
PART 1 - GENERAL
| 1.1 | SUMMARY |
| A. | Section Includes: |
Door Hardware Storefront and entrance door hardware B. Related Sections:
Section 08 11 13, HOLLOW METAL DOORS AND FRAMES Section 08 41 13, ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS C. Specific Omissions: Hardware for the following is specified or indicated elsewhere:
Windows Cabinets, including open wall shelving and locks Signs, except where scheduled Installation Rough hardware
1.2 REFERENCES
Use date of standard in effect as of Bid Date.
American National Standards Institute – ANSI 156.18 – Materials and Finishes ICC/ANSI A117.1 - 1998 – Specifications for making buildings and facilities usable by physically handicapped people ABAAS – Architectural Barriers Act Accessibility Standards BHMA – Builders Hardware Manufacturers Association DHI – Door and Hardware Institute NFPA – National Fire Protection Association
1. NFPA 80 – Fire Doors and Windows
2. NFPA 101 – Life Safety Code
3. NFPA 105 – Smoke and Draft Control Door Assemblies
4. NFPA 252 – Fire Tests of Door Assemblies UL – Underwriters Laboratories
5. UL10C – Positive Pressure Fire Tests of Door Assemblies
6. UL 305 – Panic Hardware WHI – Warnock Hersey Incorporated State of Texas Building Code Local applicable codes SDI – Steel Door Institute WI – Woodwork Institute NAAMM – National Association of Architectural Metal Manufacturers
1.3 SUBMITTALS & SUBSTITUTIONS
SUBMITTALS: Organize vertically formatted schedule into “Hardware Sets” with index of doors and headings, indicating complete designations of every item required for each door or opening. Include following information:
1. Type, style, function, size, quantity and finish of hardware items
2. Use BHMA Finish codes per ANSI A156.18
3. Name, part number and manufacturer of each item
4. Fastenings and other pertinent information
5. Location of hardware set coordinated with floor plans and door schedule
6. Explanation of abbreviations, symbols, and codes contained in schedule
7. Mounting locations for hardware
8. Door and frame sizes, materials and degrees of swing
9. List of manufacturers used and their nearest representative with address and phone number
10. Catalog cuts
1.4 QUALITY ASSURANCE
Qualifications:
1. Hardware supplier: direct factory contract supplier who employs a certified architectural hardware consultant (AHC), available at reasonable times during course of work for project hardware consultation.
a) Responsible for detailing, scheduling and ordering of finish hardware. Detailing implies that the submitted schedule of hardware is correct and complete for the intended function and performance of the openings.
Hardware: Free of defects, blemishes and excessive play. Obtain each kind of hardware (latch and locksets, exit devices, hinges and closers) from one manufacturer.
Exit Doors: Operable from inside with single motion without the use of a key or special knowledge or effort.
Fire-Rated Openings: NFPA 80 compliant. Hardware UL10C (positive pressure) compliant for given type/size opening and degree of label. Provide proper latching hardware, non-flaming door closers, approved-bearing hinges, and resilient seals. Coordinate with wood door section for required intumescent seals. Furnish openings complete.
Note: Scheduled resilient seals may exceed selected door manufacturer’s requirements.
See 2.6.E for added information regarding resilient and intumescent seals.
Furnish hardware items required to complete the work in accordance with specified performance level and design intent, complying with manufacturers’ instructions.
1.5 DELIVERY, STORAGE AND HANDLING
Delivery: Coordinate delivery to appropriate locations (shop or field).
Acceptance at Site: Items individually packaged in manufacturers’ original containers, complete with proper fasteners and related pieces. Clearly mark packages to indicate contents, locations in hardware schedule and door numbers.
Storage: Provide securely locked storage area for hardware, protect from moisture, sunlight, paint, chemicals, dust, excessive heat and cold, etc.
1.6 PROJECT CONDITIONS AND COORDINATION
Where exact types of hardware specified are not adaptable to finished shape or size of members requiring hardware, provide suitable types having as nearly as practical the same operation and quality as type specified, subject to Architect’s approval.
Coordination: Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for proper installation and function, regardless of omissions or conflicts in the information on the Contract Documents. Furnish related trades with the following information:
1. Location of embedded and attached items to concrete
2. Location of wall-mounted hardware, including wall stops
3. Location of finish floor materials and floor-mounted hardware
4. Locations for conduit and raceways as needed for electrical, electronic and electro-pneumatic hardware items. Fire/life-safety system interfacing. Point-to-point wiring diagrams plus riser diagrams to related trades.
5. Manufacturer templates to door and frame fabricators Check Shop Drawings for doors and entrances to confirm that adequate provisions will be made for proper hardware installation.
| 1.7 | WARRANTY |
| A. | Part of respective manufacturers’ regular terms of sale. Provide manufacturers’ written warranties: |
| 1. | |
| Locksets: | |
| Three years |
| 2. |
| Exit Devices: |
| Three years |
| 3. |
| Closers: |
| Ten years |
| 4. |
| Hinges: |
| One year |
| 5. |
| Other Hardware |
| Two years |
1.8 COMMISSIONING
Conduct these tests prior to request for certificate of substantial completion:
1. With installer present, test door hardware operation with climate control system at rest and while in full operation.
PART 2 - PRODUCTS
| 2.1 | MANUFACTURERS |
| A. | |
| Listed acceptable alternate manufacturers: submit for review products with equivalent function and features of scheduled products. |
| ITEM: |
| MANUFACTURER: |
| ACCEPTABLE SUB: |
| Hinges |
| (IVE) Ives |
| Bommer, Stanley |
| Key System |
| (BES) Best Lock Co. |
| None |
Locks
Electrified Hardware (BES) Best Lock Co.
(SCE) Schlage Electronics None
(SDC) Security Door Controls
| Exit Devices |
| (VON) Von Duprin |
| None |
| Closers |
| (LCN) LCN |
| None |
| Silencers |
| (IVE) Ives |
| Rockwood, Trimco |
| Stops |
| (IVE) Ives |
| Rockwood, Trimco |
| Thresholds |
| (ZER) Zero International |
| NGP, Reese |
| Seals & Bottoms |
| (ZER) Zero International |
| NGP, Reese |
| Pulls & Pushes |
| (IVE) Ives |
| Rockwood, Trimco |
2.2 HINGING METHODS
Drawings typically depict doors at 90 degrees, doors will actually swing to maximum allowable. Use wide-throw conventional or continuous hinges as needed up to 8 inches in width to allow door to stand parallel to wall for true 180-degree opening. Advise architect if 8-inch width is insufficient.
Conform to manufacturer’s published hinge selection standard for door dimensions, weight and frequency, and to hinge selection as scheduled. Where manufacturer’s standard exceeds the scheduled product, furnish the heavier of the two choices, notify Architect of deviation from scheduled hardware.
Conventional Hinges: Steel or stainless steel pins and concealed bearings. Hinge open widths minimum, but of sufficient throw to permit maximum door swing.
1. Outswinging exterior doors: non-ferrous with non-removable (NRP) pins and security studs.
2. Non-ferrous material exteriors and at doors subject to corrosive atmospheric conditions.
Pivots: high-strength forged bronze or stainless steel, tilt-on precision bearing and bearing pin.
3. Bottom and intermediate pivots: adjustability of minus 1/16 inch, plus 1/8 inch.
2.3 LOCKSETS, LATCHSETS, DEADBOLTS
A. Extra Heavy Duty Cylindrical Locks and Latches: as scheduled.
1. Chassis: Cylindrical design, corrosion-resistant plated cold-rolled steel, through-bolted.
2. Locking Spindle: Stainless steel, integrated spring and spindle design.
3. Latch Retractors: Forged steel. Balance of inner parts: corrosion-resistant plated steel, or stainless steel.
4. Latchbolt: Solid steel
5. Backset: 2-3/4" typically, more or less as needed to accommodate frame, door or other hardware.
6. Lever Trim: Accessible design, independent operation, spring-cage supported, minimum 2” clearance from lever mid-point to door face.
7. Strikes: 16 gage curved steel, bronze or brass with 1” deep box construction, lips of sufficient length to clear trim and protect clothing.
8. Lock Series and Design: Best 93K, 15D design.
9. Certifications:
a) ANSI A156.2, 1994, Series 4000, Grade 1.
b) UL listed for A label and lesser class single doors up to 4ft x 8ft.
2.4 EXIT DEVICES / PANIC HARDWARE
General features:
1. Independent lab-tested 1,000,000 cycles.
2. Push-through push-pad design. No exposed push-pad fasteners, no exposed cavities when operated. Return stroke fluid dampeners and rubber bottoming dampeners, plus anti-rattle devices.
3. 0.75-inch throw deadlocking latchbolts.
4. End caps: Impact-resistant, flush-mounted. No raised edges or lips to catch carts or other equipment.
5. No exposed screws to show through glass doors.
6. Non-handed basic device design with center case interchangeable with all functions, no extra parts required to effect change of function.
7. Releasable in normal operation with 15-lb. maximum operating force.
8. Where devices span over door lite frame and the face of the selected lite manufacturer’s frame is raised from the face of the door, furnish panic hardware manufacturer’s fitted shims or glass-bead kits at no additional cost to the project.
2.5 CLOSERS
Surface Closers: Full rack-and-pinion type cylinder with removable non-ferrous cover and cast iron body. Double heat-treated pinion shaft, single piece forged piston, chrome-silicon steel spring.
1. ISO 2000 certified. Units stamped with date-of-manufacture code.
2. Non-sized, non-handed, and adjustable. Place closer inside building, stairs, and rooms.
3. Plates, brackets and special templating when needed for interface with particular header, door and wall conditions and neighboring hardware.
4. Separate adjusting valves for closing speed, latching speed and backcheck, fourth valve for delayed action where scheduled.
5. Non-flaming fluid, will not fuel door or floor covering fires.
6. Pressure Relief Valves (PRV) not permitted.
2.6 OTHER HARDWARE
Door Stops: Provide stops to protect walls, casework or other hardware.
1. Unless otherwise noted in Hardware Sets, provide floor type with appropriate fasteners. Where floor type cannot be used, provide wall type. If neither can be used, provide overhead type.
Seals: Finished to match adjacent frame color. Resilient seal material: polyurethane, polypropylene, nylon brush, silicone rubber or solid high-grade neoprene as scheduled. Do not furnish vinyl seal material. UL label applied to seals on rated doors. Substitute products: certify that the products equal or exceed specified material’s thickness and durability.
2. Proposed substitutions: Submit for approval.
3. Solid neoprene: MIL Spec. R6855-CL III, Grade 40
4. Non-corroding fasteners at in-swinging exterior doors Exposed Through-Bolts: Do not use SNB, grommet nuts, sleeve nuts or other such clamping type fasteners, intent is for minimal exposed hardware. Coordinate with wood doors; ensure provision of proper blocking to support wood screws for mounting panic hardware and door closers. Coordinate with metal doors and frames; ensure provision of proper reinforcement to support machine screws for mounting panic hardware and door closers.
Silencers: Interior hollow metal frames, 3 for single doors, 4 for pairs of doors. Omit where adhesive mounted seal occurs. Leave no unfilled/uncovered pre-punched silencer holes.
2.7 FINISH
Generally BHMA 626 Satin Chromium
1. Areas using BHMA 626 to have push-plates, pulls and protection plates of BHMA 630, Satin Stainless Steel, unless otherwise noted.
Door closers: factory powder coated to match other hardware, unless otherwise noted.
Aluminum items: Match predominant adjacent material. Seals to coordinate with frame color.
2.8 KEYING REQUIREMENTS
Key System: Lock 7-pin key system Construction and permanent cores to be provided and installed by Dept. of Veterans Affairs; coordinate with VA locksmith.
PART 3 - EXECUTION
3.1 ACCEPTABLE INSTALLERS
Can read and understand manufacturers’ templates, suppliers’ hardware schedules and printed installation instructions. Can readily distinguish drywall screws from manufacturers’ furnished fasteners. Available to meet with manufacturers’ representatives and related trades to discuss installation of hardware.
3.2 PREPARATION
Ensure that walls and frames are square and plumb before hardware installation. Make corrections before commencing hardware installation.
Locate hardware per SDI-100 and applicable building, fire, life-safety, accessibility, and security codes.
1. Notify Architect of code conflicts before ordering material.
2. Locate levers, key cylinders, t-turn pieces, touchbars and other operable portions of latching hardware between 34 inches to 48 inches above the finished floor.
3. Where new hardware is to be installed near existing doors/hardware scheduled to remain, match locations of existing hardware.
3.3 INSTALLATION
Install hardware per manufacturer’s instructions and recommendations. Do not install surface-mounted items until finishes have been completed on substrate. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate for proper installation and operation. Remove and reinstall or replace work deemed defective by Architect.
1. Gaskets: install jamb-applied gaskets before closers, overhead stops, rim strikes, etc; fasten hardware over and through these seals. Install sweeps across bottoms of doors before astragals, cope sweeps around bottom pivots, trim astragals to tops of sweeps.
2. When hardware is to be attached to existing metal surface and insufficient reinforcement exists, use RivNuts, NutSerts or similar anchoring device for screws.
3. Use manufacturers' fasteners furnished with hardware items, or submit Request for Substitution with Architect.
4. Replace fasteners damaged by power-driven tools.
Locate floor stops no more than 4 inches from walls and not within paths of travel. See paragraph 2.2 regarding hinge widths, door should be well clear of point of wall reveal. Point of door contact no closer to the hinge edge than half the door width. Where situation is questionable or difficult, contact Architect for direction.
Locate overhead stops for minimum 90 degrees and maximum allowable degree of swing.
Drill pilot holes for fasteners in wood doors and/or frames.
3.4. ADJUSTING
Adjust and check for proper operation and function. Replace units, which cannot be adjusted to operate freely and smoothly.
1. Hardware damaged by improper installation or adjustment methods: repair or replace to Owner’s satisfaction.
2. Adjust doors to fully latch with no more than 1 pound of pressure.
3. Adjust delayed-action closers on fire-rated doors to fully close from fully-opened position in no more than 10 seconds.
4. Adjust door closers per 2.5 this section.
Inspection: Use hardware supplier’s consultant or consultant’s agent. Include supplier's report with closeout documents.
Final inspection: Installer to provide letter to Owner that upon completion installer has visited the Project and has accomplished the following:
5. Re-adjust hardware.
6. Evaluate maintenance procedures and recommend changes or additions, and instruct Owner’s personnel.
7. Identify items that have deteriorated or failed.
8. Submit written report identifying problems.
3.5 DEMONSTRATION
Demonstrate mechanical hardware and electrical, electronic and pneumatic hardware systems, including adjustment and maintenance procedures.
3.6 PROTECTION/CLEANING
Cover installed hardware, protect from paint, cleaning agents, weathering, carts/barrows, etc. Remove covering materials and clean hardware just prior to substantial completion.
Clean adjacent wall, frame and door surfaces soiled from installation/reinstallation process.
3.7 SCHEDULE OF FINISH HARDWARE
See door schedule in drawings for hardware set assignments.
HARDWARE GROUP NO. 001
USE WITH DOOR # 119b Provide each SL door(s) with the following:
| 1 |
| EA |
| CYLINDER |
| YALE 7 PIN LFIC MORTISE CYL. X (MATCH EXISTING 7 PIN GH KEYWAY) X CMK (AS REQ'D) |
| 626 |
| YAL |
ALL HARDWARE BY DOOR MANUFACTURER
B/O
HARDWARE GROUP NO. 004
USE WITH DOOR # 119A
Provide each SGL door(s) with the following:
| 1 |
| EA |
| CYLINDER |
| YALE 7 PIN LFIC MORTISE CYL. X (MATCH EXISTING 7 PIN GH KEYWAY) X CMK (AS REQ'D) |
| 626 |
| YAL |
BAL OF HARDWARE BY DOOR MANUFACTURER
B/O
COORDINATE LOCKING REQUIREMENTS WITH DOOR MANUFACTURER
HARDWARE GROUP NO. 341
USE WITH DOOR # 115b, 115c Provide each SGL door(s) with the following:
| 3 |
| EA |
| HINGE |
| 5BB1HW 4.5 X 4.5 |
| 652 |
| IVE |
| 1 |
| EA |
| PRIVACY LOCK |
| CRR 8802FL X 261 (OCCUPANCY INDICATOR) (F19) |
| 626 |
| YAL |
| 1 |
| EA |
| SURFACE CLOSER |
| 4040XP RW/PA X MTG BRKT, SPCR & PLATE AS REQ (C02011/C02021) |
| 689 |
| LCN |
| 1 |
| EA |
| KICK PLATE |
| 8400 10" X 2" LDW B-CS (J102) |
| 630 |
| IVE |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. 401
USE WITH DOORS # 117, 115A, 121C
Provide each SGL door(s) with the following:
| 1 |
| EA |
| CONT. HINGE |
| 705 |
| 630 |
| IVE |
| 1 |
| EA |
| CLASSROOM LOCK |
| CRR 8808FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F08) |
| 626 |
| YAL |
| 1 |
| EA |
| KICK PLATE |
| 8400 10" X 2" LDW B-CS (J102) |
| 630 |
| IVE |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 2 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. 501
USE WITH DOORS # 115
Provide each SGL door(s) with the following:
| 3 |
| EA |
| HINGE |
| 5BB1 4.5 X 4.5 |
| 652 |
| IVE |
| 1 |
| EA |
| CLASSROOM LOCK |
| CRR 8808FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F08) |
| 626 |
| YAL |
| 1 |
| EA |
| SURFACE CLOSER |
| 4040XP RW/PA X MTG BRKT, SPCR & PLATE AS REQ (C02011/C02021) |
| 689 |
| LCN |
| 1 |
| EA |
| KICK PLATE |
| 8400 10" X 2" LDW B-CS (J102) |
| 630 |
| IVE |
| 1 |
| EA |
| WALL STOP |
| 1270CX (L02101) |
| 626 |
| TRI |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (USE SILENCERS @ NON-RATED DOORS) |
| BK |
| ZER |
| 1 |
| EA |
| THRESHOLD |
| 545 SADDLE THRESHHOLD |
| BK |
| ZER |
HARDWARE GROUP NO. HM-4L
USE WITH DOOR # 215
Provide each SGL door(s) with the following:
| 1 |
| EA |
| CONT. HINGE |
| 705 |
| 630 |
| IVE |
| 1 |
| EA |
| CLASSROOM PUSH/PULL LATCH |
| HL6 9070 2 3/4" A (BOTH PADDLES POINTING DOWN) |
| 630 |
| SCH |
| 1 |
| EA |
| MORTISE CYLINDER |
| 2196 X CAM X COLLARS (MATCH EXISTING 7 PIN YALE GH MASTERKEY) X CMK |
| 626 |
| YAL |
| 1 |
| EA |
| KICK PLATE |
| 8400 10" X 2" LDW B-CS (J102) |
| 630 |
| IVE |
| 1 |
| EA |
| DOOR EDGE GUARD |
| KE33-1 / KE33-2 X 34" ( CUT OUT FOR HDW AS REQ'D) (J208M) |
| 630 |
| TRI |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| DOOR BOTTOM |
| 368AA (R0Y346) |
| AA |
| ZER |
| 1 |
| EA |
| THRESHOLD |
| 410 (J32300 2 1/2) |
| AL |
| NGP |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. HW-1K.PR
USE WITH DOOR # 121A
Provide each PR door(s) with the following:
| 2 |
| EA |
| CONT. HINGE |
| 705 |
| 630 |
| IVE |
| 1 |
| EA |
| CONST LATCHING BOLT |
| FB51T/FB61T (AS REQ'D) |
| 630 |
| IVE |
| 1 |
| EA |
| PUSH/PULL LATCH - BOTH HANDLES DOWN |
| HL6 9010 (F01) |
| 630 |
| SCH |
| 1 |
| EA |
| OH STOP |
| 100S (C01541) (ACTIVE LEAF) |
| 630 |
| GLY |
| 2 |
| EA |
| SURFACE CLOSER |
| 4040XP RW/PA X MTG BRKT, SPCR & PLATE AS REQ (C02011/C02021) |
| 689 |
| LCN |
| 2 |
| EA |
| ARMOR PLATE |
| 8400 34" X 1" LDW B-CS (J101) |
| 630 |
| IVE |
| 2 |
| EA |
| DOOR EDGE GUARD |
| KE33-1 / KE33-2 X 34" ( CUT OUT FOR HDW AS REQ'D) (J208M) |
| 630 |
| TRI |
| 1 |
| EA |
| WALL STOP |
| 1270CX (L02101) (INACTIVE LEAF) |
| 626 |
| TRI |
| 1 |
| EA |
| ASTRAGAL GASKET |
| 322A-S |
| A |
| ZER |
| 2 |
| EA |
| DOOR BOTTOM |
| 368AA (R0Y346) |
| AA |
| ZER |
| 2 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. HW-3E
USE WITH DOORS # 120D, 120E, 120F, 120H, 120I, 121b Provide each SGL door(s) with the following:
| 3 |
| EA |
| HINGE |
| 5BB1 4.5 X 4.5 |
| 652 |
| IVE |
| 1 |
| EA |
| ENTRY LOCK |
| CRR 8807FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F04) |
| 626 |
| YAL |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (USE SILENCERS @ NON-RATED DOORS) |
| BK |
| ZER |
| 1 |
| EA |
| COAT HOOK |
| 3070-1 (L03121) (OMIT WHERE GLASS LITE PREVENTS INSTALLATION) |
| 626 |
| TRI |
HARDWARE GROUP NO. HW-3E.1
USE WITH DOORS # 120K, 120L
Provide each SGL door(s) with the following:
| 3 |
| EA |
| HINGE |
| 5BB1HW 5 X 4.5 |
| 652 |
| IVE |
| 1 |
| EA |
| ENTRY LOCK |
| CRR 8807FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F04) |
| 626 |
| YAL |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (USE SILENCERS @ NON-RATED DOORS) |
| BK |
| ZER |
| 1 |
| EA |
| COAT HOOK |
| 3070-1 (L03121) (OMIT WHERE GLASS LITE PREVENTS INSTALLATION) |
| 626 |
| TRI |
HARDWARE GROUP NO. HW-4G
USE WITH DOOR # 118
Provide each SGL door(s) with the following:
| 3 |
| EA |
| HINGE |
| 5BB1 4.5 X 4.5 |
| 652 |
| IVE |
| 1 |
| EA |
| APARTMENT EXIT LOCK |
| CRR 8817FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F09) |
| 626 |
| YAL |
| 1 |
| EA |
| SURFACE CLOSER |
| 4040XP RW/PA X MTG BRKT, SPCR & PLATE AS REQ (C02011/C02021) |
| 689 |
| LCN |
| 1 |
| EA |
| KICK PLATE |
| 8400 10" X 2" LDW B-CS (J102) |
| 630 |
| IVE |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. HW-4K
USE WITH DOORS # 115D, 119C, 121
Provide each SGL door(s) with the following:
| 1 |
| EA |
| CONT. HINGE |
| 705 |
| 630 |
| IVE |
| 1 |
| EA |
| APARTMENT EXIT LOCK |
| CRR 8817FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F09) |
| 626 |
| YAL |
| 1 |
| EA |
| SURFACE CLOSER |
| 4040XP RW/PA X MTG BRKT, SPCR & PLATE AS REQ (C02011/C02021) |
| 689 |
| LCN |
| 1 |
| EA |
| ARMOR PLATE |
| 8400 34" X 1" LDW B-CS (J101) |
| 630 |
| IVE |
| 1 |
| EA |
| DOOR EDGE GUARD |
| KE33-1 / KE33-2 X 34" ( CUT OUT FOR HDW AS REQ'D) (J208M) |
| 630 |
| TRI |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. HW-5G.1
USE WITH DOOR # 119, 122A
Provide each SGL door(s) with the following:
| 3 |
| EA |
| HINGE |
| 5BB1 4.5 X 4.5 |
| 652 |
| IVE |
| 1 |
| EA |
| STOREROOM LOCK |
| CRR 8805FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F07) |
| 626 |
| YAL |
| 1 |
| EA |
| SURFACE CLOSER |
| 4040XP RW/PA X MTG BRKT, SPCR & PLATE AS REQ (C02011/C02021) |
| 689 |
| LCN |
| 1 |
| EA |
| KICK PLATE |
| 8400 10" X 2" LDW B-CS (J102) |
| 630 |
| IVE |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| DOOR BOTTOM |
| 368AA (R0Y346) |
| AA |
| ZER |
| 1 |
| EA |
| THRESHOLD |
| 410 (J32300 2 1/2) |
| AL |
| NGP |
| 2 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. HW-11A.SGL
USE WITH DOORS # 119D, 121D
Provide each SGL door(s) with the following:
| 1 |
| EA |
| CONT. HINGE |
| 705 |
| 630 |
| IVE |
| 1 |
| EA |
| STOREROOM LOCK |
| CRR 8805FL X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F07) |
| 626 |
| YAL |
| 1 |
| EA |
| ARMOR PLATE |
| 8400 34" X 2" LDW B-CS (J101) |
| 630 |
| IVE |
| 1 |
| EA |
| DOOR EDGE GUARD |
| KE33-1 / KE33-2 X 34" ( CUT OUT FOR HDW AS REQ'D) (J208M) |
| 630 |
| TRI |
| 1 |
| EA |
| FLOOR STOP |
| 1214 (L02121) |
| 626 |
| TRI |
| 1 |
| EA |
| GASKETING |
| 188S-B PSA H & J (ROY154) |
| BK |
| ZER |
HARDWARE GROUP NO. HW-SH-10
USE WITH DOORS # 100, 102A, 102B, 120, 209A
Provide each SGL door(s) with the following:
| 1 |
| EA |
| CONT. HINGE |
| 705 TW8 (INSTALL CON, CUT FOR ACCESS PANEL) |
| 630 |
| IVE |
| 1 |
| EA |
| ELECTRIFIED MORTISE LOCK (FAIL SECURE) |
| CRR 8891FL X REX X 1193 (7 PIN MATCH EXISTING GH KEYWAY) X CMK (F07) |
| 626 |
| YAL |
| 1 |
| EA |
| SURFACE CLOSER |
| 4040XP RW/PA X MTG BRKT, SPCR & PLATE AS REQ (C02011/C02021) |
| 689 |
| LCN |
| 1 |
| EA |
| ARMOR PLATE |
| 8400 34" X 2" LDW B-CS (J101) |
| 630 |
| IVE |
| 1 |
| EA |
| DOOR EDGE GUARD |
| KE33-1 / KE33-2 X 34" ( CUT OUT FOR HDW AS REQ'D) (J208M) |
| 630 |
| TRI |
| 1 |
| EA |
| WALL STOP |
| 1270CX (L02101) |
| 626 |
| TRI |
| 3 |
| EA |
| SILENCER |
| 1229A (L03011) |
| GRY |
| TRI |
| 1 |
| EA |
| DOOR POSITION SWITCH (AS REQ'D) |
| BY SECTION 28 13 00 |
B/O
| 1 |
| EA |
| CREDENTIAL READER / KEYPAD |
| BY SECTION 28 13 00 |
B/O
| 1 |
| EA |
| POWER SUPPLY |
| BY SECTION 28 13 00 |
B/O
OPERATIONAL DESCRIPTION: ENTRANCE BY CREDENTIAL READER OR MANUAL KEY OVER-RIDE. ALWAYS FREE EGRESS. FAIL SECURE.
For ALL FIRE RATED DOOS, PROVIDE SMOKE SEALS All Around.
- - - END - - -
DOOR HARDWARE
08 71 00 - 15
File details come from the government source that posted it. Updated .