36C25619R0072-010.pdf

PDF 6 MB Posted

Attached to
NRM 580-17-101 Expand - Renovate ER
Solicitation number
36C25619R0072
Issued by

About this file

36C25619R0072 580-17-101 Project Drawings - Plumbing.pdf

View the file

Other files

File Type Posted
36C25619C0088-000.docx DOCX document
36C25619R0072-0003002.pdf PDF
36C25619R0072-0003000.docx DOCX document
36C25619R0072-0003001.pdf PDF
36C25619R0072-0002000.docx DOCX document
36C25619R0072-0002001.docx DOCX document
36C25619R0072-0001003.pdf PDF
36C25619R0072-0001002.pdf PDF
36C25619R0072-0001004.pdf PDF
36C25619R0072-0001001.pdf PDF
36C25619R0072-0001000.docx DOCX document
36C25619R0072-003.pdf PDF
36C25619R0072-004.pdf PDF
36C25619R0072-009.pdf PDF
36C25619R0072-013.pdf PDF
36C25619R0072-011.pdf PDF
36C25619R0072-006.pdf PDF
36C25619R0072-008.pdf PDF
36C25619R0072-005.pdf PDF
36C25619R0072-001.docx DOCX document
36C25619R0072-002.docx DOCX document
36C25619R0072-012.docx DOCX document
36C25619R0072-007.pdf PDF
36C25619R0072-000.docx DOCX document
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A/E ARCHITECT / ENGINEER

AD AREA DRAIN

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISH GRADE

AG AIR GAP

AP ACCESS PANEL

AS AUTOMATIC SPRINKLER

ASD AUTOMATIC SPRINKLER DRAIN

ASHRAE AMERICAN SOCIETY HEATING,

REFRIGERATING, AIR CONDITIONING

ENGINEERS

ASME AMERICAN SOCIETY OF MECHANICAL

ENGINEERS

ASPE AMERICAN SOCIETY PLUMBING

ENGINEERS

ASR AUTOMATIC SPRINKLER RISER

AV ACID VENT

AW ACID WASTE

BFP REDUCED PRESSURE BACKFLOW

PREVENTER

BHP BREAK HORSEPOWER

BSP BLACK STEEL PIPE

BT BATHTUB

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNITS PER HOUR

C CELSIUS

CGA COMPRESSED GAS ASSOCIATION

CI CAST IRON

CO CLEANOUT

CS CLINICAL SINK

CV CONTROL VALVE

DCW DOMESTIC COLD WATER

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER RETURN

DHWS DOMESTIC HOT WATER SUPPLY

DI DEIONIZED WATER

DN DOWN

DOE DEPARTMENT OF ENERGY

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

DWH DOMESTIC WATER HEATER

DWR DRINKING WATER RETURN

DWS DRINKING WATER SUPPLY

DWV DRAIN WASTE VENT

EL ELEVATION

EMCS ENERGY MONOSERRAT AND

CENTRAL SYSTEM

EPA ENVIRONMENTAL PROTECTION

AGENCY

EPACT ENERGY POLICY ACT

ESC ESCUTCHEON

ESH EMERGENCY SHOWER

ET EXPANSION TANK

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EWS EYE WASH STATION

EX EXISTING

F FAHRENHEIT

FCO FLOOR CLEANOUT

FCW FILTERED COLD WATER

FD FLOOR DRAIN

FDC FIRE DEPARTMENT (HOSE)

CONNECTION

FM FLOW METER

FOP FUEL OIL PUMP

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FOV FUEL OIL VENT

FS FLOOR SINK

FU FIXTURE UNITS

GAL GALLON

GCO GRADE CLEANOUTS

GPD GALLONS PER DAY

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GPR GAS PRESSURE REGULATOR

GRS GAS REGULATOR STATION

GT GREASE TRAP

GVTR GAS VENT THROUGH ROOF

GWH GAS FIRED WATER HEATER

N2 NITROGEN

N2O NITROUS OXIDE

NC NORMALLY CLOSED

NG NATURAL GAS

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NOM NOMINAL

NPW NON POTABLE WATER

NTS NOT TO SCALE

02 OXYGEN

OC ON CENTER

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OR OPERATING ROOM

OVFL OVERFLOW

PA PASCAL

PD PRESSURE DROP OR DIFFERENCE

PDI PLUMBING AND DRAINAGE INSTITUTE

PG PRESSURE GAUGE

PP PLUMBING PUMP

PPM PARTS PER MILLION

PRS PRESSURE REDUCING STATION

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH

ATMOSPHERE

PSIG POUNDS PER SQUARE INCH GAUGE

PTRV PRESSURE TEMPERATURE RELIEF

VALVE

PW POTABLE WATER

RD ROOF DRAIN

RDL ROOF DRAIN LEADER

RL ROOF LEADER

RO REVERSE OSMOSIS

RWL RAIN WATER LEADER

SAN SANITARY SEWER

SCFM STANDARD CUBIC FOOT/MIN

SCW SOFTENED COLD WATER

SDMH STORM DRAIN MANHOLE

SP SUMP PUMP

SPR SPRINKLER LINE

SQFT SQUARE FOOT

SS STAINLESS STEEL

ST STORAGE TANK

SW STORM WATER

TCV TEMPERATURE CONTROL VALVE

TD TEMPERATURE DIFFERENCE

TD TRENCH DRAIN

TDH TOTAL DYNAMIC HEAD

TEMP TEMPERATURE

TMV THERMOSTATIC MIXING VALVE

TP TRAP PRIMER

TSTAT THERMOSTAT

TWR TEMPERED WATER RETURN

TWS TEMPERED WATER SUPPLY

TYP TYPICAL

UPC UNIFORM PLUMBING CODE

V VENT

VAC VACUUM

VB VACUUM BREAKER

VCO VACUUM CLEANER OUTLET

VP VACUUM PUMP

VS VENT STACK

VTR VENT THROUGH ROOF

W WASTE

WC WATER CLOSET

WCO WALL CLEANOUT

WG WATER GAUGE

WH WALL HYDRANT

WH WATER HEATER

WHA WATER HAMMER ARRESTOR

WL WATER LINE

WM WATER METER

WPD WATER PRESSURE DROP

WS WASTE STACK

YCO YARD CLEANOUT

YH YARD HYDRANT

H&CW HOT AND COLD WATER

HB HOSE BIBB

HD HUB DRAIN

HEX HEAT EXCHANGER

HP HORSEPOWER

HS HAND SINK

HST HOT WATER STORAGE TANK

(DOMESTIC)

HWB HOT WATER BOILER

HWCP HOT WATER CIRCULATING PUMP

HWP HOT WATER PUMP

HYD HYDRANT

ICW INDUSTRIAL COLD WATER

INV INVERT

IPC INTERNATIONAL PLUMBING CODE

IRW IRRIGATION WATER

IW INDIRECT WASTE

IWH INSTANTANEOUS WATER HEATER

IWR INDUSTRIAL WATER RETURN

IWS INDUSTRIAL WATER SUPPLY

KW KILOWATT

KWHR KILOWATT-HOUR

L/S LITER PER SECOND

LA LABORATORY AIR

LAV LAVATORY

LBS/HR POUNDS PER HOUR

LCW LABORATORY COLD WATER

LHW LABORATORY HOT WATER

LNG LIQUID NATURAL GAS

LOX LIQUID OXYGEN

LV LABORATORY VACUUM

LW LOW WATER

M METER

MA MEDICAL AIR

MAV MANUAL AIR VENT

MBH 1000 BTUH

MED MEDICAL

MER MECHANICAL EQUIPMENT ROOM

MH MANHOLE

MOU MEMORANDUM OF UNDERSTANDING

MSB MOP SERVICE BASIN

MV MEDICAL VACUUM

PLUMBING ABBREVIATIONS

V

SAN

PLUMBING LEGEND

GATE VALVE

GLOBE VALVE

GATE VALVE WITH 3/4" HOSE ADAPTER

CHECK VALVE

ANGLE GLOBE VALVE

BUTTERFLY VALVE

BALL VALVE

MODULATING CONTROL VALVE

BALANCING VALVE (CIRCUIT SETTER)

FE

DIRECTION OF PIPE PITCH (DOWN)

DIRECTION OF FLOW

ANCHOR

REDUCER OR INCREASER

ECCENTRIC REDUCER

TOP CONNECTION, 45° or 90°

BOTTOM CONNECTION, 45° OR 90°

SIDE CONNECTION

CAPPED OUTLET

RISE OR DROP IN PIPE

UNION

PIPE UP

PIPE DOWN

POINT OF CONNECTION BETWEEN NEW AND

EXISTING WORK

LIMIT OF DEMOLITION

WATER HAMMER ARRESTOR

FLOAT & THERMOSTATIC TRAP SET INCLUDING

PIPING ACCESSORIES

STRAINER

THERMOMETER

PRESSURE GAUGE

FLOW ELEMENT

TEMPERATURE SENSOR (AQUASTAT)

T

SANITARY SEWER PIPING

VENT PIPING

DOMESTIC COLD WATER PIPING

DOMESTIC HOT WATER PIPING

DOMESTIC HOT/COLD WATER RETURN

NON POTABLE

CONTINUATION

STORM WATER

SAN

SD

FIRE SUPPRESSIONFS

SANITARY SEWER PIPING (UNDER SLAB)

NATURAL GAS

COMPRESSED AIR

VACUUM

PIPING TO BE DEMOLISHED

OXYGEN

MV

MA

NG

O

PROJECT LIMITS OF WORK

MATCHLINE

PD104

PD103

PLUMBING LOAD SUMMARY

MARK DESCRIPTION QUANTITY DFU EACH DFU

CW WSFU

EACH

CW WSFU

HW WSFU

EACH HW WSFU

TOTAL WSFU

EACH TOTAL WSFU

P-101 WATER CLOSET, FLOOR MOUNTED, PUBLIC 5 4 20 10 50 0 0 10 50

P-114 WATER CLOSET, FLOOR MOUNTED BARIATRIC, PUBLIC 2 4 8 10 20 0 0 10 20

P-418 LAVATORY WALL HUNG, PUBLIC 25 1 25 1.5 37.5 1.5 37.5 0.7 17.5

P-505 CLINIC SERVICE SINK 0 5 5 13 10 3 3 13 13

P-608 ELECTRIC WATER COOLER HI-LOW 1 0.5 0.5 0.25 0.25 0 0

33 58.5 117.75 40.5 100.5

WATER HAMMER ARRESTOR SCHEDULE

MARK FIXTURE UNIT RATING

A 1 - 10

B 11 - 32

C 33 - 60

D 61 - 113

E 114 - 154

F 155 - 330

PLUMBING FIXTURE SCHEDULE

MARK DESCRIPTON DFU EACH CW WSFU HW WSFU TOTAL WSFU WASTE PIPE VENT PIPE COLD WATER HOT WATER

WRIST BLADE

HANDLES

ELECTRIC

SENSOR REMARKS

P-101 WATER CLOSET, FLOOR MOUNTED, PUBLIC 4 10 0 4" 2" 1" 0" Yes FLOOR MOUNTED, BACK DISCHARGE.

P-114 WATER CLOSET, FLOOR MOUNTED BARIATRIC, PUBLIC 4 10 0 4" 2" 1" 0" Yes FLOOR MOUNTED, BACK DISCHARGE BARIATRIC RATED.

P-418 LAVATORY WALL HUNG, PUBLIC 1 1.5 1.5 1 1/2" 0" 1/2" 1/2" No Yes STRAIGHT BACK, VITREOUS CHINA

P-505 CLINIC SERVICE SINK 5 13 3 4" 0" 1/2" 1/2" No Yes SEE SPECIFICATION SECTION 224000. STRAIGHT BACK, VITREOUS CHINA

P-608 ELECTRIC WATER COOLER HI-LOW 0.25 1 1/2" 1 1/2" 1/2"

ZVB-1 3 GAS VALVE BOX

1 WORK SHALL CONFORM TO APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND APPLICABLE VA STANDARDS.

2 INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS.

3 OBTAIN AND PAY FOR PERMITS, FEES, AND INSPECTIONS REQUIRED FOR THIS WORK.

4 PROVIDE NEW MATERIALS, EQUIPMENT AND PRODUCTS INCORPORATED IN THE WORK, OF A SUITABLE GRADE FOR THE PURPOSES INTENDED.

5 EQUIPMENT OR MATERIAL DEVIATIONS FROM INDICATED CONTRACT REQUIREMENTS SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT/ENGINEER. SUBMIT PROPOSED EQUIPMENT DEVIATIONS THAT ARE SIMILAR BOTH IN QUALITY AND CAPACITY TO THAT EQUIPMENT SPECIFIED, AS SOLELY DETERMINED BY THE ARCHITECT/ENGINEER.

6 INSTALL EQUIPMENT AS INDICATED, ALLOWING FOR SUFFICIENT ACCESS AND CLEARANCE SPACE FOR EQUIPMENT MAINTENANCE, REPAIRS, AND REPLACEMENT.

7 PLUMBING FIXTURES SHALL HAVE A PISTON TYPE WATER HAMMER ARRESTOR SIZED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.

8 SANITARY SEWER PIPING SHOWN IS LOCATED BELOW FLOOR SLAB OR WITHIN WALLS UNLESS NOTED OTHERWISE. SANITARY VENT PIPING SHOWN IS ABOVE THE CEILING OR

WITHIN WALLS UNLESS NOTED OTHERWISE.

9 SUPPORT PIPING SYSTEM AS REQUIRED BY LOCAL, STATE, AND NATIONAL CODES ALONG WITH SPECIFICATIONS, VA STANDARDS AND MANUFACTURER'S RECOMMENDATIONS.

10 PIPING PENETRATIONS THROUGH NEW OR EXISTING WALLS OR FLOORS SHALL BE SEALED TO EQUAL THE RATING OF THE NEW OR EXISTING WALL OR FLOOR.

11 PLUMBING SYSTEM SHALL BE TESTED AS REQUIRED PER ALL LOCAL, STATE, AND NATIONAL CODES ALONG WITH ALL VA STANDARDS.

12 COORDINATE ALL PLUMBING PIPING WITH ALL STRUCTURAL COMPONENTS.

13 DISINFECT THE DOMESTIC WATER SYSTEM IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL CODES ALONG WITH ALL VA STANDARDS.

14 PROVIDE SHUT OFF VALVES AT BRANCH PIPING TO FIXTURES.

15 COORDINATE PLUMBING WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION. CONTRACTOR SHALL COORDINATE ROUTING OF ALL PIPING WITH EXISTING CONDITIONS AND SHALL PROVIDE ANY NECESSARY OFFSETS, REROUTING, ETC. REQUIRED FOR A COMPLETE AND COORDINATED INSTALLATION.

16 PROVIDE ALL NECESSARY OFFSETS, TEES, ELBOWS, ETC. FOR A COMPLETE WORKING PLUMBING SYSTEM. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL

LOCATION AND ARRANGEMENT OF PIPING SYSTEMS.

17 CONTRACTOR SHALL COORDINATE ANY PLUMBING SYSTEM REQUIRED SHUTDOWN WITH THE OWNER 1 WEEK IN ADVANCE.

18 PATCH, PAINT AND CLEAN SURFACES SUSTAINING DAMAGE ASSOCIATED WITH PLUMBING WORK OF THIS CONTRACT, UNLESS NOTED OTHERWISE.

19 SUBMIT BOUND SET OF OPERATING AND MAINTENANCE INSTRUCTIONS FOR EQUIPMENT AT COMPLETION OF PROJECT.

20 INSTALL ESCUTCHEONS IN ALL PLACES WHERE PIPING PENETRATES A WALL IN AN EXPOSED LOCATION.

21 PIPES SHALL NOT BE ROUTED ABOVE TELECOM OR ELECTRICAL ROOMS.

PLUMBING GENERAL NOTES

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:2

P

M

P-001

PLUMBING LEGEND, ABBREVIATIONS,

AND GENERAL NOTES

1 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

* - PRIVATE FIXTURES

DocuSign Envelope ID: 7F0BDB62-5146-4079-B1A0-D12C70ECAC76

3/14/2019

20.5 20 1515.816171818.9

E

G

H

I

J

G.3

F.7

F.5

E.8

E.5

SAN

S A

N A

W S

A N

S A

N S

A N

S A

N

SAN

SAN SAN

S A

N S

A N

S A

N S

A N

S A

N S

A N

SAN

SAN

V

SAN SAN

S A

N

SAN

S A

N

SAN SAN

SAN

SANSAN

SANSAN

SANSAN

SANSAN

SAN

S A

N S

A N

V

V

V

S A

N S

A N

SAN SAN

S A

N

S A

N

S A

N

SAN

SAN

V

S A

N

SAN

V

V

SANSAN

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:3

P

M

PD101

FIRST FLOOR SANITARY DEMOLITION

PLAN

2 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

0 4 8 16 N O R

TH

TRUE

SCALE: 1/8" = 1'-0"1

FIRST FLOOR SANITARY DEMOLITION PLAN

1 DEMOLISH EXISTING PLUMBING

FIXTURE AND REMOVE ALL

ASSOCIATED SANITARY AND VENT

PIPING BACK TO LIMITS OF

DEMOLITION. CAP PIPE AT MAIN.

A SEE PP902 DOMESTIC WATER ISOMETRIC FOR

COMPLEMENTARY INFORMATION.

B COORDINATE ALL WORK WITH THE GENERAL

CONTRACTOR, OTHER TRADES, AND THE COR

TO MINIMIZE DISRUPTION OF AREAS OUTSIDE

OF THE PROJECT LIMITS OF WORK.

C ALL TIE-IN TO EXISTING COLD, HOT, AND HOT

WATER RETURN TO BE COORDINATED AND

SCHEDULED WITH VAMC. ASSUME ALL TIE-INS

WILL BE PERFORMED DURING OFF PEAK

HOURS (NIGHTS AND/OR WEEKENDS).

D COORDINATE PLUMBING INSTALLATION WITH

OTHER TRADES, OFFSET LINES AS NEEDED

TO AVOID CONFLICTS.

E PIPING HAS BEED INDICATED ON DRAWINGS

IN APPROXIMATE LOCATIONS. EXACT

ROUTING WILL BE DETERMINED IN THE FIELD.

F DO NOT SCALE DRAWING. SEE

ARCHITECTURAL DRAWINGS FOR EXACT

LOCATIONS OF ALL FIXTURES AND

EQUIPMENT.

G FIELD VERIFY ALL EXISTING PLUMBING PIPE

LOCATIONS, SIZES, AND INVERTS.

H SLEEVE ALL PENETRATIONS, FIRESTOP OR

SEAL AS REQUIRED.

I VERIFY EXISTING UNDERGROUND UTILITIES

AND LOCATIONS PRIOR TO ANY

EXCAVATIONS.

J REFER TO ARCHITECTURAL PLANS FOR

RATED WALL LOCATIONS.

K COORDINATE CLEANOUT, FLOOR DRAINS,

FLOOR ACCESS COVERS WITH

ARCHITECTURAL FINISH PLAN.

L WASTE PIPING IS BELOW FLOOR UNLESS

NOTED OTHERWISE. ALL WATER AND VENT

PIPING IN THE INTERSTITIAL SPACE UNLESS

NOTED OTHERWISE.

M ALL HANGER SUPPORTS SHALL BE INSTALLED

VERTICALLY AND UPRIGHT.

N ALL PIPES SHALL BE INSTALLED PARALLEL

AND PERPENDICULAR TO BUILDING.

G

H

I

J

G.3

F.7

F.5

E.8

E.5

3/4"3/4" 1 1/2"1 1/2"

3"3"

3/4"3/4" 1 1/2"1 1/2"

3"3" 1 1/2"1 1/2"

2 1/2"2 1/2"

3/4"3/4" 2"2"

3"3"

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:3

P

M

PD102

FIRST FLOOR DOMESTIC WATER

DEMOLITION PLAN

3 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

SCALE: 1/8" = 1'-0"1

FIRST FLOOR DOMESTIC WATER DEMOLITION PLAN

A INSTALLERS OF THESE SYSTEMS SHALL BE

ASSE 6010 CERTIFIED; TESTING PERSONNEL

SHALL BE ASSE 6020 CERTIFIED; AND

INSPECTORS AND VERIFIERS SHALL BE ASSE

6030 CERTIFIED.

B COORDINATE ALL WORK WITH THE GENERAL

CONTRACTOR, OTHER TRADES, AND THE

COR TO MINIMIZE DISRUPTION OF AREAS

OUTSIDE OF THE PROJECT LIMITS OF WORK.

C ALL TIE-IN TO EXISTING COLD, HOT, AND HOT

WATER RETURN TO BE COORDINATED AND

SCHEDULED WITH VAMC. ASSUME ALL

TIE-INS WILL BE PERFORMED DURING OFF

PEAK HOURS (NIGHTS AND/OR WEEKENDS).

D COORDINATE PLUMBING INSTALLATION WITH

OTHER TRADES, OFFSET LINES AS NEEDED

TO AVOID CONFLICTS.

E PIPING HAS BEED INDICATED ON DRAWINGS

IN APPROXIMATE LOCATIONS. EXACT

ROUTING WILL BE DETERMINED IN THE FIELD.

F DO NOT SCALE DRAWING. SEE

ARCHITECTURAL DRAWINGS FOR EXACT

LOCATIONS OF ALL FIXTURES AND

EQUIPMENT.

G FIELD VERIFY ALL EXISTING PLUMBING PIPE

LOCATIONS, SIZES, AND INVERTS.

H SLEEVE ALL PENETRATIONS, FIRESTOP OR

SEAL AS REQUIRED.

I REFER TO ARCHITECTURAL PLANS FOR

RATED WALL LOCATIONS.

J COORDINATE CLEANOUT, FLOOR DRAINS,

FLOOR ACCESS COVERS WITH

ARCHITECTURAL FINISH PLAN.

K WASTE PIPING IS BELOW FLOOR UNLESS

NOTED OTHERWISE. ALL WATER AND VENT

PIPING IN THE INTERSTITIAL SPACE UNLESS

NOTED OTHERWISE.

L ALL HANGER SUPPORTS SHALL BE

INSTALLED VERTICALLY AND UPRIGHT.

M ALL PIPES SHALL BE INSTALLED PARALLEL

AND PERPENDICULAR TO BUILDING.

1 DEMOLISH EXISTING PLUMBING FIXTURE

REMOVE ALL ASSOCIATED DOMESTIC

WATER PIPING BACK TO LIMITS OF

DEMOLITION.

2 DEMOLISH EXISTING PLUMBING PIPING BACK

TO LIMITS OF DEMOLITION. CAP PIPES AT

SHUT-OFF VALVES.

3 DEMOLISH EXISTING PLUMBING PIPE BACK

TO MAIN AND CONNECT NEW 1-1/2" PIPE AS

SHOWN ON PP104.

4 DEMOLISH EXISTING PLUMBING PIPE BACK

TO MAIN AND CONNECT NEW 3/4" PIPE AS

SHOWN ON PP104.

5 DEMOLISH EXISTING PLUMBING PIPING BACK

TO LIMITS OF DEMOLITION. CAP PIPES AT

MAIN.

0 4 8 16 N O R

TH

TRUE

G

H

I

J

G.3

F.7

F.5

E.8

E.5

BED CONTROL

1A-802A

VISC ESCORT

1A-800

AMBULANCE

VESTIBULE

C1A-811

ASSISTED CARE

1A-812

MEDS

1A-814

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:4

P

M

PD103

FIRST FLOOR MEDICAL GAS

DEMOLITION PLAN

4 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

SCALE: 1/8" = 1'-0"1

FIRST FLOOR MEDICAL GAS DEMOLITION PLAN

1 DEMOLISH EXISTING MEDICAL GAS PIPING

BACK TO LIMITS OF DEMOLITION.

2 REMOVE EXISTING MEDICAL GAS ZONE

ALARM PANEL.

3 REMOVE EXISTING MEDICAL GAS ZONE BOX.

0 4 8 16 N O R

TH

TRUE

G

H

I

J

G.3

F.7

F.5

E.8

E.5

SOILED

1A-804

PSYCH EXAM 23

1A-796

ANTE ROOM

1A-795

ISOL (NEG) EXAM

1A-794

WHEELCHAIR

SHOWER

1A-808

EQUIPMENT

STORAGE

1A-773

TLT

1A-768A EXAM 3

1A-768

EXAM 4

1A-767

EXAM 5

1A-766

PAT. TLT

1A-786

TOILET ROOM

1A-793

LINEN/OXYGEN

1A-772A

WORK RM

1A-772

TRIAGE

1A-761

TRIAGE

1A-762

TRIAGE

1A-763

TRIAGE

1A-759

TRIAGE

1A-758

BED CONTROL

1A-802A

VISC ESCORT

1A-800

OFFICE

1A-706

MEAN'S TEST.

1A-707

MEAN'S TEST.

1A-708

SOC. WORKER

1A-742

OFFICE

1A-743

TLT

1A-745

MED. DIR

1A-751

ADMIN. ASST.

1A-750

NURSE

1A-749

CODER OFFICE

1A-748 CONF ROOM

1A-746

BED CONTROL

1A-711

BED CONTROL

1A-710

OFFICE

1A-200E

WALK-IN

VESTIBULE

C1A-754

AMBULANCE

VESTIBULE

C1A-811

ASSISTED CARE

1A-812

MEDS

1A-814

RECEPTION

1A-757

CORRIDOR

C1A-764

CORRIDOR

C1A-764A

TRIAGE WORK

1A-760

CARE STATION

1A-799

REGISTRATION

CLERK

1A-709

CORRIDOR

1A-741A

CORRIDOR

1A-741B

Room

1A-741C

COPY

1A-747

STOR. RM

1A-744

CORRIDOR

C1A-774

STRETCHER

C1A-809

ER/URGENT CARE

WAITING

C1A-703

INTERVIEW

1A-765

CLEAN

1A-734

EXAM 11

1A-733

EXAM 12

1A-732

TOILET

1A-764B

BARIATRIC TOILET

1A-764C

SOILED

1A-739

EXAM 7

1A-738

EXAM 8

1A-737

EXAM 9

1A-736

EXAM 10

1A-735

EXAM 6

1A-728

EXAM 5

1A-727

EXAM 4

1A-726

EQUIPMENT

1A-740

EXAM 3

1A-722

EXAM 2

1A-723

EXAM 1

1A-724

CARE STATION

1A-729

MEDICATION

ROOM

1A-731

ALC

1A-721

NOURISHMENT

1A-740A

EXAM 24

C1A-795

RESUS 25

1A-805

STAFF TOILET

1A-764A

EQUIPMENT

1A-725

RESUS 26

1A-807

STAFF WORK

1A-730

ALCOVE

1A-734A

CORRIDOR

C1A-711

CORRIDOR

C1A-712

CORRIDOR

C1A-713

CORRIDOR

C1A-714

CORRIDOR

C1A-715

BARIATRIC TOILET

1A-753

TOILET

1A-754

TOILET

1A-755

ZVB-1

1 1/2" MV

3/4" MA

3/4" O

1 1/2" MV

1/2" MA

1/2" O

3/4" O

3/4" MA

1 1/4" MV

1/2" O

1/2" MA

3/4" MV

1/2" O

1/2" MA

3/4" MV

3/4" MV

3/4" MA

3/4" O

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:5

P

M

PG101

FIRST FLOOR MEDICAL GAS PLAN

5 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

SCALE: 1/8" = 1'-0"1

FIRST FLOOR MEDICAL GAS PLAN

1 CONNECT MEDICAL GAS VACUUM, AIR, AND

OXYGEN TO HEADWALL.

2 PROVIDE AND INSTALL NEW MEDICAL GAS

ALARM SUB PANEL TIED BACK TO EXISTING

MASTER PANEL. COORDINATE EXACT

LOCATION IN THE FIELD. PLUMBING

CONTRACTOR SHALL PROVIDE LINE

PRESSURE SWITCHES TIED BACK TO PANEL.

COORDINATE EXACT LOCATION OF

PRESSURE SWITCHES IN THE FIELD. REFER

ARCHITECTURE ELEVATIONS AND MOUNTING

HEIGHT DRAWINGS FOR EXACT LOCATION.

0 4 8 16 N O R

TH

TRUE

CO

CO

2" SAN

2" SAN

2" SAN

S A

N

S A

N

2" SAN

2" SAN

2" SAN

2" SAN2" SAN

2" SAN2" SAN

4" SAN4" SAN

2" SAN 2" SAN

S A

N

4" SAN

S A

N S

A N

S A

N S

A N

S A

N

S A

N S

A N

S A

N S

A N

S A

N

CO

CO

CO

CO

S A

N

CO

CO 4" SAN

4" S

AN

2" SAN

4" SAN4" SAN 4" SAN

S A

N

S A

N

2" SAN

2" SAN

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:5

P

M

PP100

BASEMENT INTERSTITIAL SANITARY

PLAN

6 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

0 4 8 16 N O R

TH

TRUE

SCALE: 1/8" = 1'-0"1

BASEMENT INTERSITIAL SANITARY PLAN

1 UP TO NEW PLUMBING FIXTURE.

2 COORDINATE CO LOCATION WITH COR.

A SLEEVE ALL PENETRATIONS, FIRESTOP OR

SEAL AS REQUIRED.

B ALL PIPING SHALL BE CONCEALED IN THE

PLENUM SPACE OR WALLS UNLESS NOTED

OTHERWISE.

C REFER TO ARCHITECTURAL PLANS FOR

RATED WALL LOCATIONS.

D ALL HANGER SUPPORTS SHALL BE

INSTALLED VERTICALLY AND UPRIGHT.

E ALL PIPES SHALL BE INSTALLED PARALLEL

AND PERPENDICULAR TO BUILDING.

G

H

I

J

G.3

F.7

F.5

E.8

E.5

P-101

P-418

P-418

P-101

P-114

P-418

P-418

P-418

P-101

P-101

P-418

P-114

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-505

P-608

P-418

SOILED

1A-804

PSYCH EXAM 23

1A-796

ANTE ROOM

1A-795

ISOL (NEG) EXAM

1A-794

WHEELCHAIR

SHOWER

1A-808

EQUIPMENT

STORAGE

1A-773

TLT

1A-768A

EXAM 3

1A-768

EXAM 4

1A-767

EXAM 5

1A-766

PAT. TLT

1A-786

TOILET ROOM

1A-793

TOILET ROOM

1A-792

ISOL (POS) EXAM

1A-791

ANTE

1A-790A

LINEN/OXYGEN

1A-772A

WORK RM

1A-772

TRIAGE

1A-761

TRIAGE

1A-762

TRIAGE

1A-763

TRIAGE

1A-759

TRIAGE

1A-758

TRANSFER

COORDINATORS

1A-802

BED CONTROL

1A-802A

VISC ESCORT

1A-800

CLERK

WORKROOM

1A-704

VIC

1A-705

OFFICE

1A-706

MEAN'S TEST.

1A-707

MEAN'S TEST.

1A-708

SOC. WORKER

1A-742

OFFICE

1A-743

TLT

1A-745

MED. DIR

1A-751

ADMIN. ASST.

1A-750

NURSE

1A-749

CODER OFFICE

1A-748 CONF ROOM

1A-746

BED CONTROL

1A-711

BED CONTROL

1A-710

OFFICE

1A-200E

WALK-IN

VESTIBULE

C1A-754

POLICE

1A-756

AMBULANCE

VESTIBULE

C1A-811

ASSISTED CARE

1A-812

MEDS

1A-814

CORRIDOR

C1A-810

RECEPTION

1A-757

CORRIDOR

C1A-764

CORRIDOR

C1A-764A

TRIAGE WORK

1A-760

CARE STATION

1A-799

REGISTRATION

CLERK

1A-709

CORRIDOR

1A-741A

CORRIDOR

1A-741B

Room

1A-741C

COPY

1A-747

STOR. RM

1A-744

CORRIDOR

C1A-774

STRETCHER

C1A-809

ER/URGENT CARE

WAITING

C1A-703

INTERVIEW

1A-765

CLEAN

1A-734

EXAM 11

1A-733

EXAM 12

1A-732

TOILET

1A-764B

BARIATRIC TOILET

1A-764C

SOILED

1A-739

EXAM 7

1A-738

EXAM 8

1A-737

EXAM 9

1A-736

EXAM 10

1A-735

EXAM 6

1A-728

EXAM 5

1A-727

EXAM 4

1A-726

EQUIPMENT

1A-740

EXAM 3

1A-722

EXAM 2

1A-723

EXAM 1

1A-724

CARE STATION

1A-729

MEDICATION

ROOM

1A-731

ALC

1A-721

NOURISHMENT

1A-740A

EXAM 24

C1A-795

RESUS 25

1A-805

STAFF TOILET

1A-764A

EQUIPMENT

1A-725

RESUS 26

1A-807

STAFF WORK

1A-730

ALCOVE

1A-734A

CORRIDOR

C1A-711

CORRIDOR

C1A-712

CORRIDOR

C1A-713

CORRIDOR

C1A-714

CORRIDOR

C1A-715

BARIATRIC TOILET

1A-753

TOILET

1A-754TOILET

1A-755

P-418

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:0

P

M

PP101

FIRST FLOOR SANITARY PLAN

7 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

0 4 8 16 N O R

TH

TRUE

SCALE: 1/8" = 1'-0"1

FIRST FLOOR SANITARY PLAN

1 2" WASTE DOWN TO BASEMENT INTERSTITIAL

AND 1-1/2" VENT UP TO FIRST FLOOR

INTERSTITIAL.

2 4" WASTE DOWN TO BASEMENT INTERSTITIAL

AND 2" VENT UP TO FIRST FLOOR

INTERSTITIAL.

A SLEEVE ALL PENETRATIONS, FIRESTOP OR

SEAL AS REQUIRED.

B ALL PIPING SHALL BE CONCEALED IN THE

PLENUM SPACE OR WALLS UNLESS NOTED

OTHERWISE.

C REFER TO ARCHITECTURAL PLANS FOR

RATED WALL LOCATIONS.

D ALL HANGER SUPPORTS SHALL BE

INSTALLED VERTICALLY AND UPRIGHT.

E ALL PIPES SHALL BE INSTALLED PARALLEL

AND PERPENDICULAR TO BUILDING.

G

H

I

J

G.3

F.7

F.5

E.8

E.5

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:0

P

M

PP102

FIRST FLOOR INTERSTITIAL SANITARY

PLAN

8 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

0 4 8 16 N O R

TH

TRUE

SCALE: 1/8" = 1'-0"1

FIRST FLOOR INTERSTITIAL SANITARY PLAN

A SLEEVE ALL PENETRATIONS, FIRESTOP OR

SEAL AS REQUIRED.

B ALL PIPING SHALL BE CONCEALED IN THE

PLENUM SPACE OR WALLS UNLESS NOTED

OTHERWISE.

C REFER TO ARCHITECTURAL PLANS FOR

RATED WALL LOCATIONS.

D ALL HANGER SUPPORTS SHALL BE

INSTALLED VERTICALLY AND UPRIGHT.

E ALL PIPES SHALL BE INSTALLED PARALLEL

AND PERPENDICULAR TO BUILDING.

1 DOWN TO PLUMBING FIXTURE.

SOILED

1A-804

PSYCH EXAM 23

1A-796

ANTE ROOM

1A-795

ISOL (NEG) EXAM

1A-794

WHEELCHAIR

SHOWER

1A-808

EQUIPMENT

STORAGE

1A-773

TLT

1A-768A

EXAM 3

1A-768

EXAM 4

1A-767

EXAM 5

1A-766

PAT. TLT

1A-786

TOILET ROOM

1A-793

TOILET ROOM

1A-792

ISOL (POS) EXAM

1A-791

ANTE

1A-790A

LINEN/OXYGEN

1A-772A

WORK RM

1A-772

TRIAGE

1A-761

TRIAGE

1A-762

TRIAGE

1A-763

TRIAGE

1A-759

TRIAGE

1A-758

TRANSFER

COORDINATORS

1A-802

BED CONTROL

1A-802A

VISC ESCORT

1A-800

CLERK

WORKROOM

1A-704

VIC

1A-705

OFFICE

1A-706

MEAN'S TEST.

1A-707

MEAN'S TEST.

1A-708

SOC. WORKER

1A-742

OFFICE

1A-743

TLT

1A-745

MED. DIR

1A-751

ADMIN. ASST.

1A-750

NURSE

1A-749

CODER OFFICE

1A-748 CONF ROOM

1A-746

BED CONTROL

1A-711

BED CONTROL

1A-710

OFFICE

1A-200E

WALK-IN

VESTIBULE

C1A-754

POLICE

1A-756

AMBULANCE

VESTIBULE

C1A-811

ASSISTED CARE

1A-812

MEDS

1A-814

CORRIDOR

C1A-810

RECEPTION

1A-757

CORRIDOR

C1A-764

CORRIDOR

C1A-764A

TRIAGE WORK

1A-760

CARE STATION

1A-799

REGISTRATION

CLERK

1A-709

CORRIDOR

1A-741A

CORRIDOR

1A-741B

Room

1A-741C

COPY

1A-747

STOR. RM

1A-744

CORRIDOR

C1A-774

STRETCHER

C1A-809

ER/URGENT CARE

WAITING

C1A-703

INTERVIEW

1A-765

CLEAN

1A-734

EXAM 11

1A-733

EXAM 12

1A-732

TOILET

1A-764B

BARIATRIC TOILET

1A-764C

SOILED

1A-739

EXAM 7

1A-738

EXAM 8

1A-737

EXAM 9

1A-736

EXAM 10

1A-735

EXAM 6

1A-728

EXAM 5

1A-727

EXAM 4

1A-726

EQUIPMENT

1A-740

EXAM 3

1A-722

EXAM 2

1A-723

EXAM 1

1A-724

CARE STATION

1A-729

MEDICATION

ROOM

1A-731

ALC

1A-721

NOURISHMENT

1A-740A

EXAM 24

C1A-795

RESUS 25

1A-805

STAFF TOILET

1A-764A

EQUIPMENT

1A-725

RESUS 26

1A-807

STAFF WORK

1A-730

ALCOVE

1A-734A

CORRIDOR

C1A-711

CORRIDOR

C1A-712

CORRIDOR

C1A-713

CORRIDOR

C1A-714

CORRIDOR

C1A-715

20.5 20 1515.816171818.9

E

G

H

I

J

G.3

F.7

F.5

E.8

E.5

BARIATRIC TOILET

1A-753

TOILET

1A-754TOILET

1A-755

P-101

P-418

P-418

P-101

P-114

P-418

P-418

P-418

P-101

P-101

P-418

P-114

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-505

P-608

P-418

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:1

P

M

PP103

FIRST FLOOR DOMESTIC WATER PLAN

9 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

A SLEEVE ALL PENETRATIONS, FIRESTOP OR

SEAL AS REQUIRED.

B ALL PIPING SHALL BE CONCEALED IN THE

PLENUM SPACE OR WALLS UNLESS NOTED

OTHERWISE.

C REFER TO ARCHITECTURAL PLANS FOR

RATED WALL LOCATIONS.

D ALL HANGER SUPPORTS SHALL BE

INSTALLED VERTICALLY AND UPRIGHT.

E ALL PIPES SHALL BE INSTALLED PARALLEL

AND PERPENDICULAR TO BUILDING.

SCALE: 1/8" = 1'-0"1

FIRST FLOOR DOMESTIC WATER PLAN 0 4 8 16 N

O R

TH

TRUE

1 1/2" CW AND 1/2" HW UP TO FIRST FLOOR

INTERSTITIAL.

2 1" CW UP TO FIRST FLOOR INTERSTITIAL.

3 1/2" CW UP TO FIRST FLOOR INTERSTITIAL.

G

H

I

J

G.3

F.7

F.5

E.8

E.5

1" DHW 1 1/2" DCW

1/

2" D

CW

1" D

HW

1/

2" D

CW

1/

2" D

CW

1/

2" D

CW

1" D

HW

1 1/2" DHW

2 1/2" DCW

3/4" DHWR

1 1/2" DHW

3" DCW

1/

2" D

CW

1" D

HW

3/ 4"

D

CW

1" D

HW

1" DHW

/4

D

H W

R

/4

D

C W

/4

D

H W

R

/4

D H

W

3/4" DHWR

3/4" DHW

3/4" DCW

1/2" DHW

1/2" DCW

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

BALANCING

VALVE

BALANCING

VALVE

BALANCING

VALVE

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:1

P

M

PP104

FIRST FLOOR INTERSTITIAL DOMESTIC

WATER PLAN

10 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

0 4 8 16 N O R

TH

TRUE

SCALE: 1/8" = 1'-0"1

FIRST FLOOR INTERSTITIAL DOMESTIC WATER

A SLEEVE ALL PENETRATIONS, FIRESTOP OR

SEAL AS REQUIRED.

B ALL PIPING SHALL BE CONCEALED IN THE

PLENUM SPACE OR WALLS UNLESS NOTED

OTHERWISE.

C REFER TO ARCHITECTURAL PLANS FOR

RATED WALL LOCATIONS.

D ALL HANGER SUPPORTS SHALL BE

INSTALLED VERTICALLY AND UPRIGHT.

E ALL PIPES SHALL BE INSTALLED PARALLEL

AND PERPENDICULAR TO BUILDING.

1 DOWN TO PLUMBING FIXTURE.

MINIMUM 16 GAGE GALVANIZED

STEEL PLATE 12"x48" [300x1200mm] MIN. SECURED TO

A MIN. 4 STUDS PER LAVATORY

TYP. 1/8" 1/4"

TYP. [3mm] [6mm]

1/4" [6mm] MOLLY BOLT HOLLOW WALL

ANCHOR (1 EA. SIDE OF LAV)

PLAN

NOTE:

1. AT LAVS WITH FOOT PEDAL

CONTROLS PROVIDE AN ADDITIONAL

16 GAGE GALVANIZED STEEL PLATE

12"x16" [300sx600mm] SECURED TO A

MINIMUM OF 2 STUDS PER FOOT

PEDAL.

2. PROVIDE 20 GAGE STUDS WHEN

HEIGHT EXCEEDS 12'-0" [3600mm].

STEEL WALL PLATE

WALL ANCHOR

STUDS

STEEL HANGER BY LAV MFGR

AA

FOR FIXTURE

HEIGHT SEE

ARCHITECTURAL

DRAWINGS

MIN. 5 1/4"

[131mm] GALV/

MACHINE BOLTS

WELDED TO PLATE

MIN. (3) 1/4"

[6mm] MACHINE

BOLTS W/ DOUBLE

LOCK NUTS ON

BACK SIDE

SECTION A

[9 m m

T O

F L O

O R

V A

R

IE

S

1/8" NPT PORT SEAL WITH

BRASS HEX HEAD PLUG USING

TEFLON TAPE (2 PL.)

FAUCET SEE

SPECIFICATIONS

LAMINAR FLOW

CONTROL DEVICE

OFFSET

WASTE

TRAP

PARALLEL

TO WALL

FINISHED

FLOOR

ESCUTCHEON

LOOSE

KEY STOP

F O

R F

IX

T

U R

E H

E

IG

H T

S S

A

R C

H

IT

E C

T U

R A

L D

R A

W

IN

G S

8"

/4

QUICK CLOSING

VALVE

WATER HAMMER ARRESTOR

ISOLATION VALVE

OUTLET

PROVIDE MEANS OF

ACCESS FOR

SERVICING

HANGERS - PROVIDE DOUBLE

DEFLECTION NEOPRENE (TYPE HN)

FOR FIRST TWO ON EACH SIDE OF

PUMP (SEE NOTE NO. 1)

PRESSURE GAGE

1/2" [ 15mm ]

STRAINER

FLEXIBLE CONNECTIONS

BALL OR

BUTTERFLY TYP.

BALANCING DEVICE

NOTES:

1. SUPPORT PUMP FROM PIPING ONLY. DO NOT SUPPORT PUMP FROM MOTOR.

FINISHED FLOOR

FINISHED WALL

SOLENOID

OPERATED

FLUSH VALVE

BACK

CHECK

ANGLE

STOP

GRAB BAR,

SEE ARCH.

DRAWINGS

SOLENOILD

TRANSFORMER IN JUNCTION

BOX

MOUNT ELECTRONIC

SENSOR IN 12"x16" [300x400mm] PANEL

12"x16" [300x400mm]

STAINLESS STEEL ACCESS

DOOR WITH OPERATED

CYLINDER LOCK

[1 m m

[8 m m

[4 m m

F O

R F

IX

T

U

H

IG

H

T S

S

A

C H

IT

E

C T

U R

A L D

R A

W

IN

G S

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:1

P

M

PP501

PLUMBING DETAILS

11 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

SCALE: N.T.S.1

LAVATORY MOUNTING DETAIL

SCALE: N.T.S.4

DUAL PORT SHUT-OFF VALVE WITH LOCKING HANDLE

SCALE: N.T.S.3

TYPICAL WHEELCHAIR LAVATORY DETAIL

SCALE: N.T.S.6

WATER HAMMER ARRESTOR DETAIL

SCALE: N.T.S.5

IN-LINE PUMPS - CONNECTIONS

SCALE: N.T.S.2

WATER CLOSET WALL HUNG DETAIL-SENSOR OPERATED

P-114

P-101

P-114

P-101

P-101

P-101

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418 P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-505

P-608

P-418

/2

V

/2

V

1 1/2" V

1 1/2" V

1 1/2" V

1 1/2" V

1 1/2" V

1 1/2" V

1 1/2" V

/2

V

/2

V

/2

V

/2

V

V

2" V

/2

V

2" SAN

4" SAN

4" SAN

4" SAN

4" SAN

4" SAN

2" SAN 2" S

AN

2" SAN

2" SAN

2" S

AN

2" SAN

2" SAN

2" SAN

2" SAN

2" SAN

2" SAN

2" SAN

2" SAN

2" SAN

4" SAN

4" SAN

S A

N

S A

N

2" SAN

2" SAN

CO

S A

N

2" SAN

6" S

AN

2" SAN

4" SAN

/2

S A

N

2" V

/2

V

1 1/2" V

3" V

3" V

3" V

1 1/2" V

1 1/2" V

2" V

1 1/2" V

2" V

CO

2" V

V

V

4" S

AN

4" S

AN

4" S

AN

4" S

AN

4" S

AN

4" S

AN

CO

/2

V

V

2" SAN

/2

S A

N

1 1/2" V

/2

V

2" V

1 1/2" V

1 1/2" V 1 1/2" V

V

V

/2

V

1 1/2" V

1 1/2" V

2" V 1" V

1" V

1 1/2" V 1 1/2" V

1 1/2" V

2" V

2" V 8" S

AN

4" A W1

/2

V

/2

S A

N

/2

V2" V

2" V

1 1/2" V

2" V 1 1/2" V

1 1/2" V 1 1/2" V

2" V 2" V

/2

S A

N

3" V

4" V

3" V

3" V

3" V

/2

S A

N

3" V 2" V

CO

CO

8" S

AN

8" S

AN

2" V

2" V

V

V

V

V

/2

S

A N

/2

S A

N

4" SAN

4" SAN

2" SAN

8" S

AN

8" S

AN

1 1/2" V

/2

S A

N

1 1/2" V 1 1/2" V

2" V 1 1/2" V

1 1/2" V

V

/2

V

1 1/2" V

/2

V

1 1/2" V

S A

N

S A

N

4" S

AN

S A

N

/2

S A

N

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:2

P

M

PP901

SANITARY RISER PLAN

12 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale:

SANITARY RISER PLAN

N.T.S.

P-114

P-101

P-114

P-101

P-101

P-101

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-505

P-608

P-418

3/4" DHWR

1 1/2" DHW

3" DCW

/4

D

H W

/4

D

C W

3" DCW

1 1/2" DHW

3/4" D

HW

R

1" DCW

D C

W

3/4" DHWR

1 1/2" DHW

3" DCW

3/4" DHW

1 1/4" DCW

1 1/2" D

CW

/2

D C

W

1 1/2" DCW

/2

D

H W

3/4" D

HW

R

1/2" DCW

1/2" D

CW

/2

D

C W

/2

D

H W

1/2" D

CW

3/4" DCW

3/4" DHWR

3/4" DHW

3/4" DCW 3/4" DHW

3/4" DCW

/2

D

C W

1 1/2" DCW

/2

D

C W

/2

D

H W

3" DCW

3/4" DHWR

3/4" DHW

3/4" DCW

3/4" DHW

3/4" DCW

1/2" DHW

1 1/2" DCW

1/2" DCW

1 1/2" DCW

1/2" DCW

3/4" DHWR

3/4" DHW

1 1/2" DCW

1/2" DHW

1 1/4" DCW

1 1/4" DCW

1/2" DHW

3/4" DHW

3/4" DHW

3/4" DHWR

1 1/2" DHW

3" DCW

1 1/2" DCW

1" DHW

/2

D

H W

/2

D

C W

1 1/2" DCW

1" DHW

1 1/2" DCW

/2

D

H W

/2

D

C W

1" DHW

1 1/2" DCW

1" DCW

/2

D

H W

/2

D

C W

1" DHW

1 1/2" DCW

1/2" DHW

1/2" DCW

1" DCW

1 1/2" DCW

1" DHW

1/2" DHW

1/2" DCW

1 1/2" DCW

1" DHW

1/2" DHW

1/2" DCW

1" DHW

1 1/2" DCW

1/2" DHW

1/2" DCW

1" DHW

1 1/2" DCW

1/2" DHW

1/2" DCW

1/2" DHW

1/2" DCW2 1/2" DCW

1" DHW

2 1/2" DCW

1 1/2" DHW

3/4" DHWR

3/4" DHWR

1/2" DHW

1/2" DCW

1/2" DHW

1/2" DCW

1" DHW

2 1/2" DCW

1/2" DHW

1/2" DCW

1" DCW

1" DHW

1" DHW

2 1/2" DCW

1/2" DCW

1/2" DHW1" DHW

3/4" DCW

3/4" DCW

1" DHW

1/2" DCW

1/2" DHW

1" DHW

3/4" DCW

1/2" DCW

1/2" DHW

1" DCW

1/2" DHW

1/2" DCW

1 1/4" DCW

1/2" DHW

1/2" DHWR

2" DCW

1 1/4" DHW

3/4" DHWR

1 1/2" DCW

3/4" DHWR

3/4" DHW

1 1/2" DCW

3/4" DHWR

3/4" DHW

3/4" DCW

3/4" DHW

1/2" DHW

1/2" DCW

3/4" DCW

1/2" DHW

1/2" DCW

1/2" DCW

1/2" DHW

1/2" DCW

3/8" DCW

1/2" DHW

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

ISOLATION

VALVES

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:2

P

M

PP902

DOMESTIC WATER RISER PLAN

13 13SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

SCALE:1

DOMESTIC WATER RISER PLAN

N.T.S.

Sheets
P-001 - PLUMBING LEGEND, ABBREVIATIONS, AND GENERAL NOTES
PD101 - FIRST FLOOR SANITARY DEMOLITION PLAN
PD102 - FIRST FLOOR DOMESTIC WATER DEMOLITION PLAN
PD103 - FIRST FLOOR MEDICAL GAS DEMOLITION PLAN
PG101 - FIRST FLOOR MEDICAL GAS PLAN
PP100 - BASEMENT INTERSTITIAL SANITARY PLAN
PP101 - FIRST FLOOR SANITARY PLAN
PP102 - FIRST FLOOR INTERSTITIAL SANITARY PLAN
PP103 - FIRST FLOOR DOMESTIC WATER PLAN
PP104 - FIRST FLOOR INTERSTITIAL DOMESTIC WATER PLAN
PP501 - PLUMBING DETAILS
PP901 - SANITARY RISER PLAN
PP902 - DOMESTIC WATER RISER PLAN
2019-03-14T11:46:07-0700