36C25619R0072-004.pdf

PDF 14 MB Posted

Attached to
NRM 580-17-101 Expand - Renovate ER
Solicitation number
36C25619R0072
Issued by

About this file

36C25619R0072 580-17-101 Project Drawings - General.pdf

View the file

Other files

File Type Posted
36C25619C0088-000.docx DOCX document
36C25619R0072-0003002.pdf PDF
36C25619R0072-0003000.docx DOCX document
36C25619R0072-0003001.pdf PDF
36C25619R0072-0002000.docx DOCX document
36C25619R0072-0002001.docx DOCX document
36C25619R0072-0001003.pdf PDF
36C25619R0072-0001002.pdf PDF
36C25619R0072-0001004.pdf PDF
36C25619R0072-0001001.pdf PDF
36C25619R0072-0001000.docx DOCX document
36C25619R0072-003.pdf PDF
36C25619R0072-009.pdf PDF
36C25619R0072-013.pdf PDF
36C25619R0072-011.pdf PDF
36C25619R0072-006.pdf PDF
36C25619R0072-008.pdf PDF
36C25619R0072-005.pdf PDF
36C25619R0072-001.docx DOCX document
36C25619R0072-010.pdf PDF
36C25619R0072-002.docx DOCX document
36C25619R0072-012.docx DOCX document
36C25619R0072-007.pdf PDF
36C25619R0072-000.docx DOCX document
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

V A N

J

A

D

E

F G

H

I

J K

L

M

N

P

Q R

O

6A101

EMERGENCY DEPARTMENT

EXPANSION

MICHAEL E. DEBAKEY VA MEDICAL CENTER

2002 HOLCOMBE BLVD.

HOUSTON, TEXAS 77030

100% Construction Documents

VA PROJECT NO. 580-17-101

MEDICAL CENTER ASSOC. DIRECTOR

CHIEF OF STAFF

ASSOC. DIRECTOR OF PATIENT CARE

CHIEF FES

PROJECT SECTION SUPV.

PROJECT MANAGER

GENERAL UTILITIES FOREMAN

PATIENT CARE FOREMAN

MEDICAL CENTER DIRECTOR GENERAL PROPERTIES FOREMAN

FIRE CHIEF

SUPERVISOR BIO-MED SERVICE

CHIEF LOGISTICS

PATIENTSAFETY MANAGER

SAFETY OFFICE

CIO OFFICER

INFECTION PREVENTION

CONTRACTING OFFICER

VA APPROVAL

V A

R E

G

IO

N A

L O

F F

IC

E

H O

L C

O M

B E

B L V

D

S O

U T

H L

E E

WEST LEE

EAST LEE

RESEARCH

LE CAPITAN

C A

T E

T E

R R

A C

E

RINGNESS AVE

CAMBRIDGE

CAMBRIDGE

H O

LC

O

M B E B

LV

D

E N

E R

G Y

C E

N T

E R

D R

IV

E

S H E E H A N A

V E

O L D

S P

A N

IS

H

T R

A

IL

S

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:2

P

M

G-001

COVER SHEET

1 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: No Scale

CAMPUS

Scale: No Scale

VICINITY MAP N

O R

T H

TRUE

NORTH

TRUE

DocuSign Envelope ID: 13593FA6-7439-4EC6-B042-673A01B20B29

3/14/2019

1-1/2"

DIAMETER

GRAB BAR

TOILET

TISSUE

DISPENSER

SANITARY

NAPKIN

DISPOSAL

TOILET

FIXTURE

TOILET

FIXTURE

TOILET

TISSUE

DISPENSER

1-1/2"

DIAMETER

GRAB BAR

EXPOSED

PLUMBING AT

BARRIER

FREE

LAVATORIES

SHALL BE

INSULATED.

LEVER OPERATING

CONTROLLED

SOAP DISPENSER

NOTE: SINKS IN COUNTERS TO BE

MOUNTED WITH RIM NO MORE

THAN 2'-10" HIGH AND WITH AT

LEAST 2'-3" KNEE CLEARANCE.

CLEAR

ACCESSIBLE TOILET PAPER TOWEL DISPENSER/

WASTE RECEPTICLE

TYPICAL ACCESSIBLE

CLEARANCE AT LAVATORY

TYPICAL ACCESSIBLE

LAVATORY AND MIRROR

1'-3" 1'-3"

M

IN

M A

X

M

A X

M

A X6

A

.F .F

1'-6"

3'-0" 6"

3'-0"

" 3

1'-0" 3'-6"

2'-4"

MIN

8"

MAX

6"

M

IN9

M

IN

M

IN

M A

X

17" MIN

TYPICAL URINAL

MOUNTING

CLEAR

15"

CLEAR

15"

"3

M

A X

TYPICAL TOILET NON-ACCESSIBLE

TOILET

TISSUE

DISPENSER

2'-9"

TOILET

FIXTURE

1'-6"

O F

R

IM

T

O P

W H

E R

E H

.C

A C

C E

S S

R E

Q 'D

OF DOOR WIDTH WHEN

ON WALL BEYOND

DOOR

CLOCK

NURSE

CALL

DOME

LIGHT

CLOCK OUTLET

TOWEL BAR

ACCESSIBLE

ROBE/COAT HOOK

ROBE/COAT

HOOK

TELEVISION

OUTLET

WALL MOUNTED TVCOAT RACK / COAT HOOK CLOCK & NURSE CALL DEVICESTOILET ACCESSORIES

HAND DRYER

6"

T

Y P

M A

X

F O

R S

T A

N D

IN

G

O

.C

TELEVISION

OUTLET

F O

R S

E A

T E

D

O

.C

WALL MOUNTED TACKBOARD

AND MARKERBOARD

WALL MOUNTED LECTURE UNIT

BOARD

PAPER TOWEL

DISPENSER

2'-0" AT SIDEWALLS

AT COUNTER SINKS

1'-6" AT SIDEWALLS

AT LAVATORY

4'-0" MAX TO

HIGHEST OPERABLE

POINT - IF FIRE

EXTINGUISHER

OVER 40 LBS

3'-6" MAX HT.

FIRE EXTINGUISHER

CABINET

ELECTRICAL CABINET

DUPLEX

OUTLET

SWITCH

THERMOSTAT

TELEPHONE

OR DATA

OUTLET

FIRE ALARM

PULL

INTERCOM

STATION

DUPLEX

OUTLET

COMPUTER

TERMINAL

MOP BASIN

MOP SHELF

TYPICAL JANITORS CLOSET

FIRE ALARM

CHIME WITH

VISUAL

ALARM LIGHT

FIRE ALARM

PULL STATION

FIRE ALARM

ANNUNCIATOR

FIRE ALARM

INTERCOM

STATION

INTERCOM

MASTER

STATION

INTERCOM

WALL

OUTLET

INTERCOM STATION

WALL PROTECTION

BUMPERGUARD

HANDRAIL

OR DOOR FRAME

3" TO CORNERGUARD

CORNERGUARD

DRINKING FOUNTAIN

WHEELCHAIR ACCESSIBLE

(CANTILEVERED STYLE)

17" - 19"

8" MIN

9" MIN

6" MAX

M

IN

T O

P O

F S

P O

U T

' M

A X

DIAPER CHANGING

STATION

M

IN

M A

X

MISC. WALL DEVICES

/8

/4

T O

B O

T T

O M

O F

R

F

L E

C T

IV

U R

F A

C E

O F

M

IR

R

O R

S

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:2

P

M

G-100

GENERAL INFORMATION

2 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

SHEET INDEX

SHEET # SHEET NAME DWG

OF

DWG

PP100 BASEMENT INTERSTITIAL SANITARY PLAN 6 13

PP101 FIRST FLOOR SANITARY PLAN 7 13

PP102 FIRST FLOOR INTERSTITIAL SANITARY PLAN 8 13

PP103 FIRST FLOOR DOMESTIC WATER PLAN 9 13

PP104 FIRST FLOOR INTERSTITIAL DOMESTIC WATER PLAN 10 13

PP501 PLUMBING DETAILS 11 13

PP901 SANITARY RISER PLAN 12 13

PP902 DOMESTIC WATER RISER PLAN 13 13

MECHANICAL

M-001 MECHANICAL LEGEND, ABBREVIATIONS, AND GENERAL NOTES 1 12

MD101 FIRST FLOOR CEILING HVAC DEMOLITION PLAN 2 12

MD102 FIRST FLOOR INTERSTITIAL HVAC DEMOLITION PLAN 3 12

MD103 FIRST FLOOR INTERSTITIAL MECHANICAL PIPING DEMOLITION PLAN 4 12

MH101 FIRST FLOOR CEILING PLAN 5 12

MH102 FIRST FLOOR INTERSTITIAL COMPOSITE HVAC PLAN 6 12

MH103 FIRST FLOOR INTERSTITIAL HVAC SUPPLY PLAN 7 12

MH104 FIRST FLOOR INTERSTITIAL HVAC EXHAUST/RETURN PLAN 8 12

MP101 FIRST FLOOR INTERSTITIAL MECHANICAL PIPING PLAN 9 12

MH501 MECHANICAL DETAILS 10 12

MH502 MECHANICAL CONTROLS 11 12

MH601 MECHANICAL SCHEDULES 12 12

E-001 ELECTRICAL GENERAL NOTES, SYMBOLS AND ABBREVIATIONS 1 10

ED101 FIRST FLOOR ELECTRICAL DEMOLITION PLAN 2 10

E-101 OVERALL BUILDING FLOOR PLAN 3 10

EP101 FIRST FLOOR POWER PLAN 4 10

EL101 FIRST FLOOR LIGHTING PLAN 5 10

E-401 ELECTRICAL ENLARGEMENTS 6 10

E-501 ELECTRICAL DETAILS 7 10

E-601 ONE-LINE DIAGRAM 8 10

E-602 ELECTRICAL PANEL SCHEDULES AND LUMINAIRE SCHEDULE 9 10

E-603 ELECTRICAL PANEL SCHEDULES 10 10

TK001 TECHNOLOGY GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS 1 6

TD101 TECHNOLOGY DEMOLITION 2 6

TK101 FIRST FLOOR TECHNOLOGY PLAN 3 6

TK102 FIRST FLOOR SECURITY PLAN 4 6

TK401 TECHNOLOGY ENLARGEMENTS 5 6

TK501 TECHNOLOGY DETAILS 6 6

FA001 FIRE ALARM GENERAL NOTES AND SYMBOLS 1 3

FA101 FIRST FLOOR FIRE ALARM DEMOLITION PLAN 2 3

FA102 FIRST FLOOR FIRE ALARM PLAN 3 3

SHEET INDEX

SHEET # SHEET NAME DWG

OF

DWG

GENERAL

G-001 COVER SHEET 1 9

G-100 GENERAL INFORMATION 2 9

G-102 PRE CONSTRUCTION RISK ASSESSMENT (PCRA) 3 9

G-103 INFECTION CONTROL RISK ASSESSMENT DETAILS (ICRA) 4 9

GC101 FIRST FLOOR PHASING PLAN - EXISTING 5 9

GC102 FIRST FLOOR PHASING PLAN - OVER NEW 6 9

GC103 FIRST FLOOR PHASING PLAN - OVER NEW - DEDUCTIVE ALTERNATES 7 9

GL101 OVERALL FIRST FLOOR LIFE SAFETY PLAN 8 9

GL102 FIRST FLOOR LIFE SAFETY PLAN 9 9

ARCHITECTURAL

AG001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 20

AG002 WALL PARTITION SCHEDULE 2 20

AD101 FIRST FLOOR DEMOLITION PLAN 3 20

AD121 FIRST FLOOR DEMOLITION CEILING PLAN 4 20

AE101 FIRST FLOOR PLAN 5 20

AE121 FIRST FLOOR REFLECTED CEILING PLAN 6 20

AE301 BUILDING SECTION 7 20

AE401 ENLARGED PLANS 8 20

AE402 ENLARGED PLANS 9 20

AE403 ENLARGED PLANS 10 20

AE411 INTERIOR ELEVATIONS 11 20

AE421 ENLARGED REFLECTED CEILING DETAILS 12 20

AE422 ENLARGED REFLECTED CEILING DETAILS 13 20

AE501 PLAN DETAILS 14 20

AE502 WALL SECTIONS AND DETAILS 15 20

AE601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 16 20

AE701 FINISH PLAN AND SCHEDULE 17 20

AE702 FINISH PLAN, SCHEDULE AND DETAILS 18 20

AE801 SIGNAGE 19 20

AE802 SIGNAGE 20 20

EQUIPMENT HOSPITAL

QH101 FIRST FLOOR EQUIPMENT PLAN - AREA A 1 2

QH102 FIRST FLOOR EQUIPMENT PLAN - AREA B 2 2

FIRE PROTECTION

FP001 FIRE PROTECTION LEGEND, ABBREVIATIONS, AND GENERAL NOTES 1 3

FD101 FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN 2 3

FP101 FIRST FLOOR FIRE PROTECTION PLAN 3 3

PLUMBING

P-001 PLUMBING LEGEND, ABBREVIATIONS, AND GENERAL NOTES 1 13

PD101 FIRST FLOOR SANITARY DEMOLITION PLAN 2 13

PD102 FIRST FLOOR DOMESTIC WATER DEMOLITION PLAN 3 13

PD103 FIRST FLOOR MEDICAL GAS DEMOLITION PLAN 4 13

PG101 FIRST FLOOR MEDICAL GAS PLAN 5 13

STANDARD MOUNTING HEIGHTS

ELECTRICAL

TECHNOLOGY

FIRE ALARM

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:3

P

M

G-102

PRE CONSTRUCTION RISK

ASSESSMENT (PCRA)

3 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

PRE-CONSTRUCTION RISK ASSESSMENT

(PCRA) NOTES:

DUST CONSTROL PLAN NOTES

A. THIS PROJECT INCLUDES CONSTRUCTION ENTRY VESTIBLE -

CONSTRUCTION ANTEROOM. THEY SHALL BE USED WHEN GOING INTO

CONSTRUCTION AREA AND LEAVING THE CONSTRUCTION AREA AND TIGHT

SEALS SHALL BE MAINTAINED AT THE FULL PERIMETER OF WALLS AND WALL

PENETRATIONS. ANY DUST SHALL BE IMMEDIATELY CLEANED IF TRACKED

OUTSIDE OF THE CONSTRUCTION BARRIER. UPON COMPLETION OF THE

CONSTRUCTION PHASE, DUST BARRIERS SHALL BE REMOVED CAREFULLY

AFTER VA COR'S APPROVAL TO MINIMIZE SPREADING OF DUST AND THE

CONTRACTOR SHALL HAVE TEMPORARY DUST PROTECTION IN PLACE

BEFORE REMOVAL OF A PERMANENT BARRIER.

INTERNAL DEMOLITION AND CONSTRUCTION ACTIVITIES DUST AND DEBRIS

CONTROL

B. TRAFFIC CONTROL: DESIGNATED ENTRY AND EXIT PROCEDURES SHALL BE

DEFINED. EGRESS PATHS SHALL BE FREE OF DEBRIS; DESIGNATED

ELEVATORS SHALL BE USED DURING SCHEDULED TIMES; AND ONLY

AUTHORIZED PERSONNEL SHALL BE ALLOWED TO ENTER THE

CONSTRUCTION ZONE. SIGNAGE SHALL DIRECT PEDESTRIAN TRAFFIC AWAY

FROM THE CONSTRUCTIOIN AREA AND MATERIALS.

C. CONTRACTOR SHALL USE TWO CARTS TO TRANSFER CONSTRUCTION

MATERIAL AND OUT OF THE PROJECT - CLEAN CART SHALL BE USED; THE

NOT-SO-CLEAN CART SHALL BE USED BETWEEN THE MAIN ENTRY AND THE

CONSTRUCTION STAGING PREP AREA.

D. DEMOLITION DEBRIS: DEBRIS SHALL BE REMOVED IN CARTS WITH TIGHTLY

FITTED COVERS, USING DESIGNATED TRAFFIC ROUTE. EFFORTS SHALL BE

MADE TO MINIMIZE USE OF ELEVATORS WITH AN EMPHASIS ON TRANSPORT

DURING THE LOWEST PERIOD OF ACTIVITY. DEBRIS SHALL BE REMOVED

DAILY AND AT TIMES SPECIFIED BY THE COR. IF CHUTES ARE USED TO

DIRECT DEBRIS OUTSIDE, HIGH EFFICIENCY PARTICULATE AIR (HEPA)

FILTERED NEGATIVE AIR MACHINES SHALL BE USED, AND THE CHUTE

OPENING SHALL BE SEALED WEHN NOT IN USE. FILTERS SHALL BE BAGGED

AND SEALED BEFORE BEING TRANSPORTED OUT OF THE CONSTRUCTION

AAREA. THE CONTRACTOR SHALL NOT HAUL DEBRIS THROUGH PATIENT-

CARE AREAS WITHOUT PRIOR APPROVAL OF THE COR.

E. EXTERIOR WINDOWS: EXISTING WINDOWS SHALL BE PROTECTED TO

PREVENT DAMAGE BY ADJACENT CONSTRUCTION WORK.

VENTILATION AND ENVIRONMENTAL CONTROLS

F. AIR SYSTEM FLOW: THE COR VERIFY AND ACKNOWLEDGE CONTRACTOR

WHETHER THE CONSTRUCTION AREA USES FRESH/OUTSIDE OR RE-

CIRCUATED AIR; FILTERS SHALL BE ADDED OR RETURN VENTS COVERED AS

NEEDED WITH FILTER MATERIAL OR PLASTIC. AIR MUST FLOW FROM CLEAN

TO DIRTY PLACES.

G. NEGATIVE AIR PRESSURE: THE AIR WITHIN THE CONSTRUCTION AREA SHALL

BE NEGATIVE WITH RESPECT TO SURROUNDING AREAS AND WITH NO

DISRUPTION OF AIR SYSTEMS OF ADJACENT AREAS. USE OF THE NEGATIVE

AIR PRESSURE SYSTEM WITHIN THE ENCLOSURE TO REMOVE DUST SHALL

PASS AIR THROUGH AN INDUSTRIAL GRADE PORTABLE HEPA FILTER

CAPABLE OF FILTRATION RATES OF 300-800 CUBIC FEET PER MINUTE

(9FT3/MIN), OR EXHAUST AIR DIRECTLY TO THE OUTSIDE IF APPROVED BY

COR. IF EXHAUST SHALL BE TIED INTO A RE-CIRCULATED AIR SYSTEM, PRE-

FILTER AND HEPA FILTER SHALL BE USED BEFORE EXHAUST TO PREVENT

CONTAMINATION OF THE DUCTS.

H. ADJACENT AREAS: THE STATUS OF SEALED PENETRATIONS AND INTACT

CEILIING SHALL BE VERIFIED DAILY.

I. AIR EXCHANGE RATES AND PRESSURE RELATIONSHIPS: VAMC AND

CONTRACTOR SHALL VERIFY AND MAINTAIN PROPER RATES IN CRITICAL

AREAS NEAR CONSTRUCTION ACTIVITY AND ENSURE AIR IS NOT BEING RE-

CIRCUATED WITHOUT FILTRATION FROM THE CONSTRUCTION AREA

ELSEWHERE. PROVIDE AIR PRESSURE TESTING THOUGHOUT THE PROJECT

IN THE FREQUENCY AS IDENTIFIED BY THE COR.

CONTAMINATION OF PATIENT ROOMS, SUPPLIES, EQUIPMENT AND RELATED

AREAS

J. WORKSITE CLOTHING: CONTRACTOR PERSONNEL CLOTHING SHALL BE

FREE OF LOOSE SOIL AND DEBRIS BEFORE LEAVING THE CONSTRUCTION

AREA. IF PROTECTIVE APPAREL IS NOT WORN (E.G., COVERALLS, FOOTGEAR

AND HEADGEAR) A HEPA-FILTERED VACUUM SHALL BE USED TO REMOVE

DUST FROM CLOTHING BEFORE LEAVING THE BARRICADE. THE

CONTRACTOR SHALL CONSTRUCT AN ANTEROOM FOR CHANGING

CLOTHING AND STORING EQUIPMENT (DESIGNATED AREA. ALL EQUIPMENT,

TOOLS, TOOL CARTS, AND MATERIALS TRANSPORTED THROUGH OCCUPIED

AREAS SHALL BE MADE FREE FROM DUST AND MOISTURE BY VACUUMING

AND WET WIPING BEFORE THEIR REMOVAL FROM THE CONSTRUCTION

ZONE OR WORK AREA.

K. POST CONSTRUCTION: DO NOT REMOVE BARRIERS AND KEEP ALL HVAC

ISOLATION UNTIL CONTRACTOR HAS CLEANED CONSTRUCTION SITE, VA

EMS STAFF HAS DONE A TERMINAL CLEANING, AND VA INFECTIOUS DISEASE

CONTROL HAS INSPECTED AND APPROVED THE CLEANING.

GENERAL

L. PROVIDE TEMPORARY 1-HOUR RATED SLAB-TO-SLAB BARRIERS CONSIST OF

3-5/8" METAL STUD FRAMING WITH 5/8" ON BOTH SIDES. BARRIERS SHALL BE

INSPECTED BY VA PCRA STAFF PRIOR TO START OF CONSTRUCTION IN

SPACE. MAINTAIN NEGATIVE PRESSURE VENTILATION IN THE

CONSTRUCTION SPACE.

M. USE ISOLATION CART FOR ALL WORK IN THIS AREA.

N. PROVIDE TWO STICKY MATS AT EACH CONSTRUCTION ACCESS POINT IN ALL

PHASES.

O. PROVIDE TWO STICKY MATS AT EACH CONSTRUCTION ACCESS POINT IN ALL

PHASES.

P. VA REQUIRES THAT ALL APPLICABLE PERMITS BE COMPLETED AND

APPROVED PRIOR TO BEGINNING ANY WORK ON STATION.

PERMITS INCLUDE:

ICRA, PCRA, ILSM, ABOVE CEILING, FIRE/SMOKE

WALL, UTILITY, FIRE SPRINKLER, FIRE ALARM SYSTEM, MEDICAL GASES,

CONFINED SPACE AND HOT WORK.

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:3

P

M

G-103

INFECTION CONTROL RISK

ASSESSMENT DETAILS (ICRA)

4 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: No Scale

ICRA DETAILS

CJCJ

CJ

CJ

CJ

CJ

CJ

EJ

EJ

FD

CSWK 9CSWK 9

GP17

TB(3)

TB(22)

HEATING STRIP

FEC

W A

LL

20.5 20 1515.816171819

E

G

H

I

J

G.3

F.8

F.5

E.8

E.5

EXIS

TIN

G

EXPA

N

SIO

N

JO

IN

T

E X

IS

T

IN

G

X P

A N

S

IO

N J

O

IN

T

GEN. EXAM

1A-805

MEDS

1A-804

PSYCH EXAM

1A-796

ANTE ROOM

1A-795

ISOLATION

EXAM

1A-794

WHEELCHAIR

SHOWER

1A-808

TREATMENT

BAY

IA-807 EQUIPMENT

STORAGE

1A-773

TLT

1A-768A

EXAM 3

1A-768

EXAM 4

1A-767

EXAM 5

1A-766

EXAM 10

1A-780

EXAM 9

1A-779

EXAM 8

1A-778

EXAM 7

1A-777

EXAM 11

1A-782

EXAM 12

1A-783

EXAM 13

1A-784

EXAM 14

1A-785

PAT. TLT

1A-786

TOILET

ROOM

1A-793

TOILET

ROOM

1A-792

GYN. EXAM

1A-791

STORAGE

1A-790A

LINEN

1A-772A

WORK RM

1A-772

WAITING

C1A-765

TRIAGE

1A-761

TRIAGE

1A-762

TRIAGE

1A-763

TRIAGE

1A-759

TRIAGE

1A-758

PAT. TOILET

1A-740

EKG

1A-739

FAST TRACK

1A-738

FAST TRACK

1A-737

FAST TRACK

1A-736 PHYSICIANS

WORKROOM

1A-719

EXAM 4

1A-718

EXAM 3

1A-717

EXAM 2

1A-716

EXAM 1

1A-715

EMS

1A-714

VITAL SIGNS

1A-713 EXAM 5

1A-724

EXAM 10

1A-726

EXAM 11

1A-727

EXAM 12

1A-728

EXAM 13

1A-729

EXAM 14

1A-730

EXAM 9

1A-720

EXAM 8

1A-721

EXAM 7

1A-722

EXAM 6

1A-723

MEN'S

RESTROOM

1A-734

WOMEN'S

RESTROOM

1A-733

TRANSFER

COORDINATORS

1A-802

BED

CONTROL

1A-802A

VISC ESCORT

1A-800

CLERK

WORKROOM

1A-704

VIC

1A-705

Room

MEAN'S

TEST.

1A-707

MEAN'S

TEST.

1A-708

SOC.

WORKER

1A-742

OFFICE

1A-743

TLT

1A-745

MED. DIR

1A-751

ADMIN. ASST.

1A-750

NURSE

1A-749

CODER

OFFICE

1A-748 CONF ROOM

1A-746

BED

CONTROL

1A-711

BED

CONTROL

1A-710

OFFICE

1A-200E

WALK-IN

VESTIBULE

C1A-754

POLICE

1A-756

AMBULANCE

VESTIBULE

C1A-811

ISOLATION

1A-813

BED 4

BED 3

BED 2

BED 1

ASSISTED

CARE

1A-812

MEDS

1A-814

CORRIDOR

C1A-810

RECEPTION

1A-757

CORRIDOR

C1A-764

CORRIDOR

C1A-764A

TRIAGE

WORK

1A-760

EXAM 18

1A-790

EXAM 17

1A-789

EXAM 16

1A-788

EXAM 15

1A-787

NURSE

CONTROL

1A-799

STAFF/PHYS.

WORKSTATIONS

1A-798

Room

ADMISSIONS

CLERK

1A-775

NOURISHMENT

1A-781

GERIATRIC

CLERK

1A-712

REGISTRATION

CLERK

1A-709

CORRIDOR

1A-741A

CORRIDOR

1A-741B

Room 1A-741C

COPY

1A-747

STOR. RM

1A-744

CORRIDOR

C1A-735

CORRIDOR

C1A-732

CORRIDOR

C1A-725

CORRIDOR

C1A-774

CORRIDOR

C1A-776

CORRIDOR

C1A-801

CORRIDOR

C1A-800

CORRIDOR

C1A-802

STRETCHER

C1A-809

CORRIDOR

C1A-731

GERIATRIC

WAITING

C1A-702

REGISTRATION

WAITING

C1A-701

ER/URGENT

CARE

WAITING

C1A-703

PHASE 1A

PHASE 2B

PHASE 2B

PHASE 2A

LIMITS

OF WORK

18.9

PHASE 1B

CHASE

ELEVATOR

PHASE 2B

3 8

S

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:4

P

M

GC101

FIRST FLOOR PHASING PLAN -

EXISTING

5 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: 1/8" = 1'-0"

FIRST FLOOR EXISTING PLAN - FOR INFORMATION ONLY

1. SHEET GC101 PROVIDED FOR INFORMATION

ABOUT EXISTING CONDITIONS.

2. REFER TO SHEET GC102 FOR PHASING PLAN.

3. REFER TO SHEET GC103 FOR DEDUCT ALTERNATE

PLAN.

1 PHASE 1A (4873 SF) – RENOVATE MAJORITY OF

EXPANSION SPACE. THE EXISTING FAST TRACK

AREA MUST REMAIN OPERATIONAL DURING THIS

TIME, ACCESSED BY THE DOOR CONSTRUCTED

IN PHASE 1A.

2 PHASE 1B (1013 SF) - ADD ONE ADDITION EXAM

ROOM, ONE CLEAN STORAGE ROOM, STAFF

TOILET, INTERVIEW ROOM, MEDICATION

STORAGE, AND ALCOVE SPACE.

3 PHASE 2A (63 SF) - RENOVATE FOR TWO EXAM

ROOMS 1A-794 AND 1A791 AND TOILETS. 1A-793

AND STORAGE 1A-990A TO BE ANTE ROOMS FOR

NEW ISOLATION EXAM ROOMS.

4 DEDUCTIVE ALTERNATE 1 - ELIMINATE THE

SWITCHABLE GLASS FOR THE EXAM ROOM

SLIDING DOORS AND ADD CUBICLE CURTAINS.

5 DEDUCTIVE ALTERNATE 2 - ELIMINATE PHASE 2B ,

RESUSCITATION ROOM AND NEW MEDICATION

STORAGE, WORK FROM PROJECT SCOPE OF

WORK.

6 DEDUCTIVE ALTERNATE 3 - ELIMINATE EXAM

ROOM SLIDING DOORS. ADD CUBICAL CURTAINS

IN L-SHAPE. CONTRACTOR TO PROVIDE A UNIT

PRICE FOR SLIDERS VS. CURTAIN/DOOR AND

FRAME.

7 PHASE 2B (341 SF) RENOVATE FOR ONE NEW

RESUSCITATION ROOM. REMOVE THE WALL

BETWEEN WORK ROOM 1A-772 AND LINEN

1A-772A CREATING ONE SPACE, NEW MEDS

STORAGE 1A-804.

8 ADD NEW DOOR OPENING, FRAME, DOOR AND

HARDWARE BETWEEN EXISTING ISOLATION

ROOM AND EXISTING TOILET ROOM.

# SHEET KEY NOTES:

A

A

CJCJ

CJ

CJ

CJ

CJ

CJ

EJ

EJ

FD

CSWK 9CSWK 9

GP17

TB(3)

TB(22)

HEATING STRIP

FEC

W A

LL

A A

A

20.5 20 1515.816171819

E

G

H

I

J

G.3

F.8

F.5

E.8

E.5

PHASE 1A

PHASE 1B

PHASE 2A

PHASE 2B

Calculating...

4873 SF

PHASE 1A

77 SF

PHASE 2B

50 SF

PHASE 2A13 SF

PHASE 2A

264 SF

PHASE 2B

1013 SF

PHASE 1B

1 4

1 4

1 4

Room

1 4

1 4

LIMITS OF WORK

18.9

ELEVATOR

CHASE

CR

PB

PB

PB

CR

CR

PB

CR

5 7

161 SF

PHASE 2B

EGRESS PATH

EGRESS PATH TAG

EGRESS PATH TAG -

COMMON PATH

EGRESS IDENTIFICATION

AREA OF REFUGE

HAZARDOUS LOCATION

FIRE EXTINGUISHER BRACKET

FIRE EXTINGUISHER CABINET

FIRE BLANKET CABINET

EMERGENCY RESPONSE

REFERENCE

CONTROLLED ACCESS -

ALWAYS UNLOCKED IN

DIRECTION OF EGRESS

KNOX BOX

DELAYED EGRESS W/ ALARM

SMOKE COMPARTMENTS

(MAX 40,000 SF

PER NFPA 101.21.3.7.2

ABD 19.3.7.1)

CARD READER

PUSH BUTTON

CA

DE

KB

XXX

XXX

FEB

FEC

FBC

CAPACITYCLR

EXTERIOR

EXIT

XX" ###

EXIT

IDENTIFICATION

EGRESS CLEAR

WIDTH EGRESS

CAPACITY

CR

PB

S

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:1

P

M

GC102

FIRST FLOOR PHASING PLAN - OVER

NEW

6 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: 1/8" = 1'-0"

FIRST FLOOR PHASING PLAN

1 PHASE 1A (4873 SF) – RENOVATE MAJORITY OF

EXPANSION SPACE. THE EXISTING FAST TRACK

AREA MUST REMAIN OPERATIONAL DURING THIS

TIME, ACCESSED BY THE DOOR CONSTRUCTED

IN PHASE 1A.

2 PHASE 1B (1013 SF) - ADD ONE ADDITION EXAM

ROOM, ONE CLEAN STORAGE ROOM, STAFF

TOILET, INTERVIEW ROOM, MEDICATION

STORAGE, AND ALCOVE SPACE.

3 PHASE 2A (63 SF) - RENOVATE FOR TWO EXAM

ROOMS 1A-794 AND 1A791 AND TOILETS. 1A-793

AND STORAGE 1A-990A TO BE ANTE ROOMS FOR

NEW ISOLATION EXAM ROOMS.

4 DEDUCTIVE ALTERNATE 1 - ELIMINATE THE

SWITCHABLE GLASS FOR THE EXAM ROOM

SLIDING DOORS AND ADD CUBICLE CURTAINS.

5 DEDUCTIVE ALTERNATE 2 - ELIMINATE PHASE 2B ,

RESUSCITATION ROOM AND NEW MEDICATION

STORAGE, WORK FROM PROJECT SCOPE OF

WORK.

6 DEDUCTIVE ALTERNATE 3 - ELIMINATE EXAM

ROOM SLIDING DOORS. ADD CUBICAL CURTAINS

IN L-SHAPE. CONTRACTOR TO PROVIDE A UNIT

PRICE FOR SLIDERS VS. CURTAIN/DOOR AND

FRAME.

7 PHASE 2B (341 SF) RENOVATE FOR ONE NEW

RESUSCITATION ROOM. REMOVE THE WALL

BETWEEN WORK ROOM 1A-772 AND LINEN

1A-772A CREATING ONE SPACE, NEW MEDS

STORAGE 1A-804.

8 ADD NEW DOOR OPENING, FRAME, DOOR AND

HARDWARE BETWEEN EXISTING ISOLATION

ROOM AND EXISTING TOILET ROOM.

A. WORK FOR THE PROJECT SHALL BE PHASED TO

ALLOW THE VA TO MAINTAIN OPERATIONS OF THE

EMERGENCY DEPARTMENT AT ALL TIMES DURING

THE COMPLETE LIFE OF THE PROJECT, DURING

BOTH DEMOLITION AND CONSTRUCTION FOR

EACH PHASE.

B. AT THE START OF EACH PHASE, PROVIDE

INFECTION CONTROL MEASURES INCLUDING

TEMPORARY PARTITIONS, CONSTRUCTION

ACCESS ANTEROOMS, HEPA-FILTERED EXHAUST,

AND USE OF MOBILE CONTAINMENT CARTS PER

ICRA REQUIREMENTS TO PREVENT THE SPREAD

OF DUST AND CONTAMINANTS TO ADJACENT

OCCUPIED AREAS. MAINTAIN INFECTION

CONTROL MEASURES AT ALL TIMES THROUGH

THE COMPLETE LIFE OF THE PROJECT. REFER TO

G-103 FOR STANDARD INFECTION CONTROL

MEASURES.

PHASING LEGEND

LEGEND

# SHEET KEY NOTES:

A

CJ

CJCJ

CJ

CJ

CJ

CJ

CJ

EJ

EJ

FD

CSWK 9CSWK 9

GP17

TB(3)

TB(22)

HEATING STRIP

FEC

W A

LL

A A

A

EGRESS PATH

EGRESS PATH TAG

EGRESS PATH TAG -

COMMON PATH

EGRESS IDENTIFICATION

AREA OF REFUGE

HAZARDOUS LOCATION

FIRE EXTINGUISHER BRACKET

FIRE EXTINGUISHER CABINET

FIRE BLANKET CABINET

EMERGENCY RESPONSE

REFERENCE

CONTROLLED ACCESS -

ALWAYS UNLOCKED IN

DIRECTION OF EGRESS

KNOX BOX

DELAYED EGRESS W/ ALARM

SMOKE COMPARTMENTS

(MAX 40,000 SF

PER NFPA 101.21.3.7.2

ABD 19.3.7.1)

CARD READER

PUSH BUTTON

CA

DE

KB

XXX

XXX

FEB

FEC

FBC

CAPACITYCLR

EXTERIOR

EXIT

XX" ###

EXIT

IDENTIFICATION

EGRESS CLEAR

WIDTH EGRESS

CAPACITY

CR

PB

20.5 20 1515.816171819

E

G

H

I

J

G.3

F.8

F.5

E.8

E.5

AE301

AE301

AE411

AE411

AE411

AE411

AE411

9 10

AE411

AE411

AE411

AE411

18.9

LIMITS

OF WORK

1 4 6

1 4 6

1 4 6

1 4 6

1 4 6

1 4 6

1 4 6

1 4 6

1 4 6

1 4 6

1 4 6

S

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:2

P

M

GC103

FIRST FLOOR PHASING PLAN - OVER

NEW - DEDUCTIVE ALTERNATES

7 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

1 PHASE 1A (4873 SF) – RENOVATE MAJORITY OF

EXPANSION SPACE. THE EXISTING FAST TRACK

AREA MUST REMAIN OPERATIONAL DURING THIS

TIME, ACCESSED BY THE DOOR CONSTRUCTED

IN PHASE 1A.

2 PHASE 1B (1013 SF) - ADD ONE ADDITION EXAM

ROOM, ONE CLEAN STORAGE ROOM, STAFF

TOILET, INTERVIEW ROOM, MEDICATION

STORAGE, AND ALCOVE SPACE.

3 PHASE 2A (63 SF) - RENOVATE FOR TWO EXAM

ROOMS 1A-794 AND 1A791 AND TOILETS. 1A-793

AND STORAGE 1A-990A TO BE ANTE ROOMS FOR

NEW ISOLATION EXAM ROOMS.

4 DEDUCTIVE ALTERNATE 1 - ELIMINATE THE

SWITCHABLE GLASS FOR THE EXAM ROOM

SLIDING DOORS AND ADD CUBICLE CURTAINS.

5 DEDUCTIVE ALTERNATE 2 - ELIMINATE PHASE 2B ,

RESUSCITATION ROOM AND NEW MEDICATION

STORAGE, WORK FROM PROJECT SCOPE OF

WORK.

6 DEDUCTIVE ALTERNATE 3 - ELIMINATE EXAM

ROOM SLIDING DOORS. ADD CUBICAL CURTAINS

IN L-SHAPE. CONTRACTOR TO PROVIDE A UNIT

PRICE FOR SLIDERS VS. CURTAIN/DOOR AND

FRAME.

7 PHASE 2B (341 SF) RENOVATE FOR ONE NEW

RESUSCITATION ROOM. REMOVE THE WALL

BETWEEN WORK ROOM 1A-772 AND LINEN

1A-772A CREATING ONE SPACE, NEW MEDS

STORAGE 1A-804.

8 ADD NEW DOOR OPENING, FRAME, DOOR AND

HARDWARE BETWEEN EXISTING ISOLATION

ROOM AND EXISTING TOILET ROOM.

A. WORK FOR THE PROJECT SHALL BE PHASED TO

ALLOW THE VA TO MAINTAIN OPERATIONS OF

THE EMERGENCY DEPARTMENT AT ALL TIMES

DURING THE COMPLETE LIFE OF THE PROJECT,

DURING BOTH DEMOLITION AND

CONSTRUCTION FOR EACH PHASE.

B. AT THE START OF EACH PHASE, PROVIDE

INFECTION CONTROL MEASURES INCLUDING

TEMPORARY PARTITIONS, CONSTRUCTION

ACCESS ANTEROOMS, HEPA-FILTERED

EXHAUST, AND USE OF MOBILE CONTAINMENT

CARTS PER ICRA REQUIREMENTS TO PREVENT

THE SPREAD OF DUST AND CONTAMINANTS TO

ADJACENT OCCUPIED AREAS. MAINTAIN

INFECTION CONTROL MEASURES AT ALL TIMES

THROUGH THE COMPLETE LIFE OF THE

PROJECT. REFER TO G-103 FOR STANDARD

INFECTION CONTROL MEASURES.

C. REFER TO GC102 FOR PHASING PLAN.

# SHEET KEY NOTES:

LEGEND

1/8" = 1'-0"

FIRST FLOOR DEDUCT ALTERNATE PLAN - NEW

T-5

M7250

R7000 M3150 M3150 R7000

M

M

F0535 F0535

C1A-101

VEST

C

RASH C

ART

STRETC

HER

TRASHCONDUMENTS

COUNTER CABINET

COUNTERPASTRY

CJ

FFC

CJ FFC

FFC

CRCR

FFC

CJ

CJCJCJCJCJCJCJ

FFC

CJ

CJ

CJ

FFC

CJ

CJ

CJ

CJ

CJ

CJ

FFC

CJFFC

FFC

CJ

CJ

CJ

CJ

FFC FFC

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ CJ CJ CJ CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

FFC

CJ

FFC

EXAM TABLE

EXAM TABLE

EXAM TABLE

EXAM TABLE

ADMIN ASST

MEDICATION RM.

CONS

1A-276A

DIETICIAN

SECY.

TMT/WAIST

MED & TMT

PROCPROC

EKG

COPY RM.

CONS

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

FD

FD

FD FD

BELOW

FD

BELOW

BELOWBELOW

FD

FD

FD

FD

FDFD

FD

FD FD

FDFD

FD

FD

FDFD

FD FD

FDFDFD

FD FD FD

FD

FD FD

FD

FD

4" CONC PAD

FD FD FD

FD

FD FD

FD

FDFD FD

FD FD

FD

FD FD

FDFDFD

FD

FD

FD

FD

FDFD

FD FD

FD FDFD

FD

FD

FDFDFD

FD FD FD

FD

FD

FD

FD

FD

FD

FDFD

FD

FD

FD

CSWK 9

4" CONC PAD

4" CONC PAD

T37(3)

DISPLAY CAB

CSWK41

T22E

FIAO4(VV)

T6(4)

VL3-24

GMA151

TOP 10B

FIN ENDS

VL31-36(3)(L)

VL4-36(3)(L)

TOP 10B

FIA01 (VV)

FTG38

TC (12)

FIN END

4" RAD.

CSWH4

GPB

4" CONC PAD

TC14

TB(3)

TB(8)

CSWK 51

CABINET

ROLLING

CART

T7B(2)

TD(17)

TD(6)

CSWK 51

CSWK 2

SIM FIN END

T6B(2)

T35 (2)

4" CONC PAD

CSWK 52

FHVEC

VL4-30 T5C(2)

T6AT6B (2)

T6A

T18C3

CSWK 52

4" CONC. PAD

CSWK 9

4" CONC PAD

GP17

TB(3)

TB(22)

T7 T-10

4" CONC PAD

TD(22)TD(22)

1 1

HEATING STRIP

TV

PAC

MAN

TV FOR

GAMES

TV FOR

MOVIES

FEC

REF

PRINTER

COPIER

GP35

GP35

GP35

GP26

Z1P01

CSWK

Z1J02

Z1E01

Z1E04

Z1E02E

Z1E01E

Z1E10

Z1E02

Z1A02A Z1A01A

Z1K01

Z1K02

Z1K03

Z1K04

Z1K05

Z 1G

Z1G04

Z1G02

Z1G03

Z1G05

Z1H01 Z1F01

Z1F05 Z1F06 Z1F07

Z1F01F

Z1F10

Z 1F

W

AL

L

UPS FEDX

FD

w c wc wc

E

D C C

AWAY FROM DIRECT

SUNLIGHT

FOR USE IN

AC ENVIRONMENT

ONLY

24238 SF

EXISTING

AMBULATORY

HEALTH CARE

OCCUPANCY

21025 SF

EXISTING

SMOKE

COMPARTMENT

H

11933 SF

EXISTING

SMOKE

COMPARTMENT

M

22885 SF

EXISTING

SMOKE

COMPARTMENT

D

21859 SF

EXISTING

SMOKE

COMPARTMENT

C

23541 SF

EXISTING

SMOKE

COMPARTMENT

B

21837 SF

EXISTING

SMOKE

COMPARTMENT

A

13837 SF

EXISTING

SMOKE

COMPARTMENT

135445

SF

EXISTING

BUSINESS

OCCUPANCY

7687 SF

EXISTING

SMOKE

COMPARTMENT

L

LIMITS OF WORK

EXISTING AMBULATORY HEALTH CARE

OCCUPANCY

EXISTING BUSINESS OCCUPANCY

EXISTING SMOKE COMPARTMENT

EXISTING SMOKE COMPARTMENT A

EXISTING SMOKE COMPARTMENT B

EXISTING SMOKE COMPARTMENT C

EXISTING SMOKE COMPARTMENT D

EXISTING SMOKE COMPARTMENT H

EXISTING SMOKE COMPARTMENT L

EXISTING SMOKE COMPARTMENT M

GL102

EGRESS PATH

EGRESS PATH TAG

EGRESS PATH TAG -

COMMON PATH

EGRESS IDENTIFICATION

AREA OF REFUGE

HAZARDOUS LOCATION

FIRE EXTINGUISHER BRACKET

FIRE EXTINGUISHER CABINET

FIRE BLANKET CABINET

EMERGENCY RESPONSE

REFERENCE

CONTROLLED ACCESS -

ALWAYS UNLOCKED IN

DIRECTION OF EGRESS

KNOX BOX

DELAYED EGRESS W/ ALARM

SMOKE COMPARTMENTS

(MAX 40,000 SF

PER NFPA 101.21.3.7.2

ABD 19.3.7.1)

CARD READER

PUSH BUTTON

CA

DE

KB

XXX

XXX

FEB

FEC

FBC

CAPACITYCLR

EXTERIOR

EXIT

XX" ###

EXIT

IDENTIFICATION

EGRESS CLEAR

WIDTH EGRESS

CAPACITY

CR

PB

S

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:4

P

M

GL101

OVERALL FIRST FLOOR LIFE SAFETY

PLAN

8 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: 1/32" = 1'-0"

FIRST FLOOR LIFE SAFETY - OCCUPANCY AND SMOKE COMPARTMENTS

THE LIFE SAFETY PLAN RECEIVED BY APOGEE CONSULTING GROUP INDICATES THE

SMOKE COMPARTMENTS ILLUSTRATED BELOW. BASED ON THESE SMOKE

COMPARTMENTS AND THE 2-HOUR FIRE BARRIER LOCATIONS SHOWN ON THE SAME

RECEIVED LIFE SAFETY PLAN, IT IS BELIEVED THAT THE EXISTING EMERGENCY

DEPARTMENT AND EXPANSION SPACE ARE ALREADY PART OF THE HEALTHCARE

OCCUPANCY. WITH THIS ASSUMPTION, MOST WALL RATINGS OF THE FACILITY ARE

CORRECT IN THEIR CURRENT STATE.

COMPARTMENT LEGEND

C1A-101

VEST

CJ

CJCJCJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

EJ

EJ

FD

FD

FD

FD

FD

FD FDFDFD

FDFDFD

FD FD FD

FD

FD

FD

FD

FD

FD

FD

CSWK 9CSWK 9

GP17

TB(3)

TB(22)

T7 T-10

HEATING STRIP

FEC

Z1K01

Z1K02

Z1K03

Z 1G

Z1G02

W

AL

L

UPS FEDX

24238 SF

EXISTING

AMBULATORY

HEALTH CARE

OCCUPANCY

7687 SF

EXISTING

SMOKE

COMPARTMENT

L

LIMITS OF WORK

CAPACITYCLR

72" 360

CAPACITYCLR

36" 180

CAPACITYCLR

36" 180

CAPACITYCLR

72" 360

EXISTING 2-HR

SEPARATION

EXISTING 2-HR

SEPARATION

EXISTING 2-HR

SEPARATION

EXISTING 2-HR

SEPARATION

EXISTING AMBULATORY HEALTH CARE

OCCUPANCY

EXISTING BUSINESS OCCUPANCY

EXISTING SMOKE COMPARTMENT H

EXISTING SMOKE COMPARTMENT L

FEC

FEC

VERTICAL SHAFTS

(per IBC 39.3.1)

EGRESS WIDTH

(per IBC 1009.2, 1018.2)

COMMON PATH OF TRAVEL

(per IBC 1014)

EXIT ACCESS TRAVEL DATA

(per IBC 21.2.6, 7.7.2, 7.6)

DEAD-END CORRIDOR

(per IBC 1018.4)

STAIR ENCLOSURES

(per IBC XX - XX)

1 HR RATED

STAIRWAYS - 44"

EGRESS COMPONENTS - 44"

100 IF IN SUITE

NOT MORE THAN 50% OF REQ. NUMBER OF EXITS

50 FEET

1 HR RATED

OCCUPANT LOAD

(per NFPA 7.3.1.2, IBC 1004.1.1)

150 AMBULATORY CARE

TRAVEL DISTANCE

(per IBC 1016.1)

TRAVEL DISTANCE BETWEEN ROOM DOOR AND

EXIT ACCESS SHALL NOT EXCEED 200 FEET WITH

SPRINKLER SYSTEM

EGRESS PATH

EGRESS PATH TAG

EGRESS PATH TAG -

COMMON PATH

EGRESS IDENTIFICATION

AREA OF REFUGE

HAZARDOUS LOCATION

FIRE EXTINGUISHER BRACKET

FIRE EXTINGUISHER CABINET

FIRE BLANKET CABINET

EMERGENCY RESPONSE

REFERENCE

CONTROLLED ACCESS -

ALWAYS UNLOCKED IN

DIRECTION OF EGRESS

KNOX BOX

DELAYED EGRESS W/ ALARM

SMOKE COMPARTMENTS

(MAX 40,000 SF

PER NFPA 101.21.3.7.2

ABD 19.3.7.1)

CARD READER

PUSH BUTTON

CA

DE

KB

XXX

XXX

FEB

FEC

FBC

CAPACITYCLR

EXTERIOR

EXIT

XX" ###

EXIT

IDENTIFICATION

EGRESS CLEAR

WIDTH EGRESS

CAPACITY

CR

PB

A. REFER TO SHEET AG001 FOR ABBREVIATIONS..

B. REFER TO PLUMBING DRAWINGS FOR

INFORMATION CONCERNING PLUMBING

FIXTURES AND PIPING SYSTEM(S).

C. REFER TO MECHANICAL DRAWINGS FOR

INFORMATION CONCERNING HVAC SYSTEM(S).

D. REFER TO ELECTRICAL DRAWINGS FOR

INFORMATION CONCERNING POWER, LIGHTING

AND COMMUNICATION SYSTEM(S).

E. REFER TO FIRE ALARM DRAWINGS FOR FIRE

ALARM NOTIFICATION AND EMERGENCY EGRESS

LIGHTING LOCATIONS.

F. REFER TO PARTITION TYPES FOR FURTHER FIRE

SEPARATION REQUIREMENTS.

G. PROVIDE ALL ADDITIONAL FRAMING NECESSARY

FOR ALL OPENINGS AND SUPPLEMENTAL

FRAMING ABOVE PARTITIONS.

H. ALL FIRE RATED ASSEMBLIES SHALL BE

INSTALLED IN ACCORDANCE WITH TESTED

ASSEMBLIES INDICATED.

I. EXTEND FIRE RATED PARTITIONS, BARRIERS,

AND OTHER SEPARATIONS TO BOTTOM OF

FLOOR DECK ABOVE (OR AS DIRECTED BY UL

ASSEMBLY). SEAL JOINT BETWEEN EDGES OF

PARTITION WITH FIRE RATED SEALANT AND/OR

INTUMESCENT ASSEMBLY.

J. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES

SHALL BE FIRE-SEALED IN ACCORDANCE WITH

APPROVED MANUFACTURER'S DETAIL FOR

LOCATION, TYPE OF CONSTRUCTION,

PENETRATING ITEM AND RATING REQUIRED.

K. ALL DUCTWORK, DIFFUSERS AND GRILLES

PENETRATING FIRE-RATED WALLS, CEILINGS

AND FLOORS SHALL HAVE THE APPROPRIATE

TYPE OF FIRE/SMOKE DAMPER IN ACCORDANCE

WITH THE TYPE OF CONSTRUCTION BEING

PENETRATED AND THE FIRE/SMOKE RATING

REQUIRED.

L. ALL LIGHT FIXTURES AND ELECTRICAL DEVICES

PENETRATING FIRE-RATED ASSEMBLIES SHALL

BE UL-LISTED FOR INSTALLATION IN THE

ASSEMBLY OR SHALL BE INSTALLED SUCH THAT

THE FIRE-RATING IS NOT COMPROMISED.

M. SMOKE RESISTANT CONSTRUCTION SHALL MEET

THE REQUIREMENTS OF ALL APPLICABLE

CODES. AREA SHALL BE SEPARATED FROM THE

REMAINDER OF THE BUILDING BE

CONSTRUCTION CAPABLE OF RESISTING THE

PASSAGE OF SMOKE. THE PARTITIONS SHALL

EXTEND FROM THE FLOOR TO THE UNDERSIDE

OF THE FLOOR OR ROOF ASSEMBLY ABOVE.

DOORS SHALL BE SELF OR AUTOMATIC

CLOSING. DOORS SHALL NOT HAVE AIR

TRANSFER OPENINGS AND SHALL NOT BE

UNDERCUT IN EXCESS OF CLEARANCE

PERMITTED WITH ACCORDANCE TO NFPA 80.

N. STORAGE OF ANY FLAMMABLE OR

COMBUSTIBLE LIQUIDS IS UNDERSTOOD TO NOT

BE WITHIN THE BUILDING. STORAGE OF ANY

MATERIAL IS TO BE IN COMPLIANCE WITH ALL

APPLICABLE CODES AND AUTHORITIES HAVING

JURISDICTION.

S

TAT E O F N E VA

D A

T H

E O

D

ORE JOHN MOW

EN

JRR

EG

ISTERED

No. 7867

A R C H I T E C

T

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:1

P

M

GL102

FIRST FLOOR LIFE SAFETY PLAN

9 9TM HM

HOUSTON VAMC ED

EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

March 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: 1/16" = 1'-0"

LIFE SAFETY PLAN - EGRESS

PROPOSED USE:

OWNED BY: PRIVATE

LOCAL GOVERNMENT

CITY/COUNTY

STATE

CODE ENFORCEMENT JURISDICTION: CITY

COUNTY

APPLICABLE CODES:

GENERAL CODE INFORMATION:

NEW CONSTRUCTION

RENOVATION (EXISTING BUILDING)

CONSTRUCTION TYPE:

MIXED CONSTRUCTION

SPRINKLERED

MEZZANINE

MIXED OCCUPANCY

PRIMARY OCCUPANCY:

SECONDARY OCCUPANCY:

PROJECT NAME:

PROJECT ADDRESS:

OWNER OR AGENT:

TYPE I

HEALTHCARE

STORAGE

NFPA 1 FIRE CODE: 2018

ADA: 2010

NFPA 10 PORTABLE FIRE EXTINGUSIHER: 2018

NFPA 13 FIRE SPRINKLER SYSTEM: 2016

NFPA 70 NATIONAL ELECTRIC CODE: 2017

NFPA 99 HEALTH CARE FACILITY. CODE: 2018

INTERNATIONAL BUILDING CODE: 2018

NFPA 101 LIFE SAFETY CODE: 2018

PG-18-13 BARRIER FREE DESIGN: 2017

ABA-ARCH. BARRIERS ACT: 20##

INTERNATIONAL EXISTING BUILDING CODE: 2018

HOUSTON VAMC ED EXPANSION

Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030

Department of Veterans Affairs

CODE INFORMATION

FEDERAL

LEGEND

- MAX TRAVEL DISTANCE COMMON PATH WITHIN A

SUITE 100 LF.

COMPARTMENT LEGEND

EGRESS DATA:

Sheets
G-001 - COVER SHEET
G-100 - GENERAL INFORMATION
G-102 - PRE CONSTRUCTION RISK ASSESSMENT (PCRA)
G-103 - INFECTION CONTROL RISK ASSESSMENT DETAILS (ICRA)
GC101 - FIRST FLOOR PHASING PLAN - EXISTING
GC102 - FIRST FLOOR PHASING PLAN - OVER NEW
GC103 - FIRST FLOOR PHASING PLAN - OVER NEW - DEDUCTIVE ALTERNATES
GL101 - OVERALL FIRST FLOOR LIFE SAFETY PLAN
GL102 - FIRST FLOOR LIFE SAFETY PLAN
2019-03-14T11:34:16-0700
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it.