36C25619R0072-004.pdf
PDF 14 MB Posted
- Attached to
- NRM 580-17-101 Expand - Renovate ER
- Solicitation number
- 36C25619R0072
About this file
36C25619R0072 580-17-101 Project Drawings - General.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25619C0088-000.docx | DOCX document | |
| 36C25619R0072-0003002.pdf | ||
| 36C25619R0072-0003000.docx | DOCX document | |
| 36C25619R0072-0003001.pdf | ||
| 36C25619R0072-0002000.docx | DOCX document | |
| 36C25619R0072-0002001.docx | DOCX document | |
| 36C25619R0072-0001003.pdf | ||
| 36C25619R0072-0001002.pdf | ||
| 36C25619R0072-0001004.pdf | ||
| 36C25619R0072-0001001.pdf | ||
| 36C25619R0072-0001000.docx | DOCX document | |
| 36C25619R0072-003.pdf | ||
| 36C25619R0072-009.pdf | ||
| 36C25619R0072-013.pdf | ||
| 36C25619R0072-011.pdf | ||
| 36C25619R0072-006.pdf | ||
| 36C25619R0072-008.pdf | ||
| 36C25619R0072-005.pdf | ||
| 36C25619R0072-001.docx | DOCX document | |
| 36C25619R0072-010.pdf | ||
| 36C25619R0072-002.docx | DOCX document | |
| 36C25619R0072-012.docx | DOCX document | |
| 36C25619R0072-007.pdf | ||
| 36C25619R0072-000.docx | DOCX document |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
V A N
J
A
D
E
F G
H
I
J K
L
M
N
P
Q R
O
6A101
EMERGENCY DEPARTMENT
EXPANSION
MICHAEL E. DEBAKEY VA MEDICAL CENTER
2002 HOLCOMBE BLVD.
HOUSTON, TEXAS 77030
100% Construction Documents
VA PROJECT NO. 580-17-101
MEDICAL CENTER ASSOC. DIRECTOR
CHIEF OF STAFF
ASSOC. DIRECTOR OF PATIENT CARE
CHIEF FES
PROJECT SECTION SUPV.
PROJECT MANAGER
GENERAL UTILITIES FOREMAN
PATIENT CARE FOREMAN
MEDICAL CENTER DIRECTOR GENERAL PROPERTIES FOREMAN
FIRE CHIEF
SUPERVISOR BIO-MED SERVICE
CHIEF LOGISTICS
PATIENTSAFETY MANAGER
SAFETY OFFICE
CIO OFFICER
INFECTION PREVENTION
CONTRACTING OFFICER
VA APPROVAL
V A
R E
G
IO
N A
L O
F F
IC
E
H O
L C
O M
B E
B L V
D
S O
U T
H L
E E
WEST LEE
EAST LEE
RESEARCH
LE CAPITAN
C A
T E
T E
R R
A C
E
RINGNESS AVE
CAMBRIDGE
CAMBRIDGE
H O
LC
O
M B E B
LV
D
E N
E R
G Y
C E
N T
E R
D R
IV
E
S H E E H A N A
V E
O L D
S P
A N
IS
H
T R
A
IL
S
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:2
P
M
G-001
COVER SHEET
1 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
Scale: No Scale
CAMPUS
Scale: No Scale
VICINITY MAP N
O R
T H
TRUE
NORTH
TRUE
DocuSign Envelope ID: 13593FA6-7439-4EC6-B042-673A01B20B29
3/14/2019
1-1/2"
DIAMETER
GRAB BAR
TOILET
TISSUE
DISPENSER
SANITARY
NAPKIN
DISPOSAL
TOILET
FIXTURE
TOILET
FIXTURE
TOILET
TISSUE
DISPENSER
1-1/2"
DIAMETER
GRAB BAR
EXPOSED
PLUMBING AT
BARRIER
FREE
LAVATORIES
SHALL BE
INSULATED.
LEVER OPERATING
CONTROLLED
SOAP DISPENSER
NOTE: SINKS IN COUNTERS TO BE
MOUNTED WITH RIM NO MORE
THAN 2'-10" HIGH AND WITH AT
LEAST 2'-3" KNEE CLEARANCE.
CLEAR
ACCESSIBLE TOILET PAPER TOWEL DISPENSER/
WASTE RECEPTICLE
TYPICAL ACCESSIBLE
CLEARANCE AT LAVATORY
TYPICAL ACCESSIBLE
LAVATORY AND MIRROR
1'-3" 1'-3"
M
IN
M A
X
M
A X
M
A X6
A
.F .F
1'-6"
3'-0" 6"
3'-0"
" 3
1'-0" 3'-6"
2'-4"
MIN
8"
MAX
6"
M
IN9
M
IN
M
IN
M A
X
17" MIN
TYPICAL URINAL
MOUNTING
CLEAR
15"
CLEAR
15"
"3
M
A X
TYPICAL TOILET NON-ACCESSIBLE
TOILET
TISSUE
DISPENSER
2'-9"
TOILET
FIXTURE
1'-6"
O F
R
IM
T
O P
W H
E R
E H
.C
A C
C E
S S
R E
Q 'D
OF DOOR WIDTH WHEN
ON WALL BEYOND
DOOR
CLOCK
NURSE
CALL
DOME
LIGHT
CLOCK OUTLET
TOWEL BAR
ACCESSIBLE
ROBE/COAT HOOK
ROBE/COAT
HOOK
TELEVISION
OUTLET
WALL MOUNTED TVCOAT RACK / COAT HOOK CLOCK & NURSE CALL DEVICESTOILET ACCESSORIES
HAND DRYER
6"
T
Y P
M A
X
F O
R S
T A
N D
IN
G
O
.C
TELEVISION
OUTLET
F O
R S
E A
T E
D
O
.C
WALL MOUNTED TACKBOARD
AND MARKERBOARD
WALL MOUNTED LECTURE UNIT
BOARD
PAPER TOWEL
DISPENSER
2'-0" AT SIDEWALLS
AT COUNTER SINKS
1'-6" AT SIDEWALLS
AT LAVATORY
4'-0" MAX TO
HIGHEST OPERABLE
POINT - IF FIRE
EXTINGUISHER
OVER 40 LBS
3'-6" MAX HT.
FIRE EXTINGUISHER
CABINET
ELECTRICAL CABINET
DUPLEX
OUTLET
SWITCH
THERMOSTAT
TELEPHONE
OR DATA
OUTLET
FIRE ALARM
PULL
INTERCOM
STATION
DUPLEX
OUTLET
COMPUTER
TERMINAL
MOP BASIN
MOP SHELF
TYPICAL JANITORS CLOSET
FIRE ALARM
CHIME WITH
VISUAL
ALARM LIGHT
FIRE ALARM
PULL STATION
FIRE ALARM
ANNUNCIATOR
FIRE ALARM
INTERCOM
STATION
INTERCOM
MASTER
STATION
INTERCOM
WALL
OUTLET
INTERCOM STATION
WALL PROTECTION
BUMPERGUARD
HANDRAIL
OR DOOR FRAME
3" TO CORNERGUARD
CORNERGUARD
DRINKING FOUNTAIN
WHEELCHAIR ACCESSIBLE
(CANTILEVERED STYLE)
17" - 19"
8" MIN
9" MIN
6" MAX
M
IN
T O
P O
F S
P O
U T
' M
A X
DIAPER CHANGING
STATION
M
IN
M A
X
MISC. WALL DEVICES
/8
/4
T O
B O
T T
O M
O F
R
F
L E
C T
IV
U R
F A
C E
O F
M
IR
R
O R
S
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:2
P
M
G-100
GENERAL INFORMATION
2 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
SHEET INDEX
SHEET # SHEET NAME DWG
OF
DWG
PP100 BASEMENT INTERSTITIAL SANITARY PLAN 6 13
PP101 FIRST FLOOR SANITARY PLAN 7 13
PP102 FIRST FLOOR INTERSTITIAL SANITARY PLAN 8 13
PP103 FIRST FLOOR DOMESTIC WATER PLAN 9 13
PP104 FIRST FLOOR INTERSTITIAL DOMESTIC WATER PLAN 10 13
PP501 PLUMBING DETAILS 11 13
PP901 SANITARY RISER PLAN 12 13
PP902 DOMESTIC WATER RISER PLAN 13 13
MECHANICAL
M-001 MECHANICAL LEGEND, ABBREVIATIONS, AND GENERAL NOTES 1 12
MD101 FIRST FLOOR CEILING HVAC DEMOLITION PLAN 2 12
MD102 FIRST FLOOR INTERSTITIAL HVAC DEMOLITION PLAN 3 12
MD103 FIRST FLOOR INTERSTITIAL MECHANICAL PIPING DEMOLITION PLAN 4 12
MH101 FIRST FLOOR CEILING PLAN 5 12
MH102 FIRST FLOOR INTERSTITIAL COMPOSITE HVAC PLAN 6 12
MH103 FIRST FLOOR INTERSTITIAL HVAC SUPPLY PLAN 7 12
MH104 FIRST FLOOR INTERSTITIAL HVAC EXHAUST/RETURN PLAN 8 12
MP101 FIRST FLOOR INTERSTITIAL MECHANICAL PIPING PLAN 9 12
MH501 MECHANICAL DETAILS 10 12
MH502 MECHANICAL CONTROLS 11 12
MH601 MECHANICAL SCHEDULES 12 12
E-001 ELECTRICAL GENERAL NOTES, SYMBOLS AND ABBREVIATIONS 1 10
ED101 FIRST FLOOR ELECTRICAL DEMOLITION PLAN 2 10
E-101 OVERALL BUILDING FLOOR PLAN 3 10
EP101 FIRST FLOOR POWER PLAN 4 10
EL101 FIRST FLOOR LIGHTING PLAN 5 10
E-401 ELECTRICAL ENLARGEMENTS 6 10
E-501 ELECTRICAL DETAILS 7 10
E-601 ONE-LINE DIAGRAM 8 10
E-602 ELECTRICAL PANEL SCHEDULES AND LUMINAIRE SCHEDULE 9 10
E-603 ELECTRICAL PANEL SCHEDULES 10 10
TK001 TECHNOLOGY GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS 1 6
TD101 TECHNOLOGY DEMOLITION 2 6
TK101 FIRST FLOOR TECHNOLOGY PLAN 3 6
TK102 FIRST FLOOR SECURITY PLAN 4 6
TK401 TECHNOLOGY ENLARGEMENTS 5 6
TK501 TECHNOLOGY DETAILS 6 6
FA001 FIRE ALARM GENERAL NOTES AND SYMBOLS 1 3
FA101 FIRST FLOOR FIRE ALARM DEMOLITION PLAN 2 3
FA102 FIRST FLOOR FIRE ALARM PLAN 3 3
SHEET INDEX
SHEET # SHEET NAME DWG
OF
DWG
GENERAL
G-001 COVER SHEET 1 9
G-100 GENERAL INFORMATION 2 9
G-102 PRE CONSTRUCTION RISK ASSESSMENT (PCRA) 3 9
G-103 INFECTION CONTROL RISK ASSESSMENT DETAILS (ICRA) 4 9
GC101 FIRST FLOOR PHASING PLAN - EXISTING 5 9
GC102 FIRST FLOOR PHASING PLAN - OVER NEW 6 9
GC103 FIRST FLOOR PHASING PLAN - OVER NEW - DEDUCTIVE ALTERNATES 7 9
GL101 OVERALL FIRST FLOOR LIFE SAFETY PLAN 8 9
GL102 FIRST FLOOR LIFE SAFETY PLAN 9 9
ARCHITECTURAL
AG001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 20
AG002 WALL PARTITION SCHEDULE 2 20
AD101 FIRST FLOOR DEMOLITION PLAN 3 20
AD121 FIRST FLOOR DEMOLITION CEILING PLAN 4 20
AE101 FIRST FLOOR PLAN 5 20
AE121 FIRST FLOOR REFLECTED CEILING PLAN 6 20
AE301 BUILDING SECTION 7 20
AE401 ENLARGED PLANS 8 20
AE402 ENLARGED PLANS 9 20
AE403 ENLARGED PLANS 10 20
AE411 INTERIOR ELEVATIONS 11 20
AE421 ENLARGED REFLECTED CEILING DETAILS 12 20
AE422 ENLARGED REFLECTED CEILING DETAILS 13 20
AE501 PLAN DETAILS 14 20
AE502 WALL SECTIONS AND DETAILS 15 20
AE601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 16 20
AE701 FINISH PLAN AND SCHEDULE 17 20
AE702 FINISH PLAN, SCHEDULE AND DETAILS 18 20
AE801 SIGNAGE 19 20
AE802 SIGNAGE 20 20
EQUIPMENT HOSPITAL
QH101 FIRST FLOOR EQUIPMENT PLAN - AREA A 1 2
QH102 FIRST FLOOR EQUIPMENT PLAN - AREA B 2 2
FIRE PROTECTION
FP001 FIRE PROTECTION LEGEND, ABBREVIATIONS, AND GENERAL NOTES 1 3
FD101 FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN 2 3
FP101 FIRST FLOOR FIRE PROTECTION PLAN 3 3
PLUMBING
P-001 PLUMBING LEGEND, ABBREVIATIONS, AND GENERAL NOTES 1 13
PD101 FIRST FLOOR SANITARY DEMOLITION PLAN 2 13
PD102 FIRST FLOOR DOMESTIC WATER DEMOLITION PLAN 3 13
PD103 FIRST FLOOR MEDICAL GAS DEMOLITION PLAN 4 13
PG101 FIRST FLOOR MEDICAL GAS PLAN 5 13
STANDARD MOUNTING HEIGHTS
ELECTRICAL
TECHNOLOGY
FIRE ALARM
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:3
P
M
G-102
PRE CONSTRUCTION RISK
ASSESSMENT (PCRA)
3 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
PRE-CONSTRUCTION RISK ASSESSMENT
(PCRA) NOTES:
DUST CONSTROL PLAN NOTES
A. THIS PROJECT INCLUDES CONSTRUCTION ENTRY VESTIBLE -
CONSTRUCTION ANTEROOM. THEY SHALL BE USED WHEN GOING INTO
CONSTRUCTION AREA AND LEAVING THE CONSTRUCTION AREA AND TIGHT
SEALS SHALL BE MAINTAINED AT THE FULL PERIMETER OF WALLS AND WALL
PENETRATIONS. ANY DUST SHALL BE IMMEDIATELY CLEANED IF TRACKED
OUTSIDE OF THE CONSTRUCTION BARRIER. UPON COMPLETION OF THE
CONSTRUCTION PHASE, DUST BARRIERS SHALL BE REMOVED CAREFULLY
AFTER VA COR'S APPROVAL TO MINIMIZE SPREADING OF DUST AND THE
CONTRACTOR SHALL HAVE TEMPORARY DUST PROTECTION IN PLACE
BEFORE REMOVAL OF A PERMANENT BARRIER.
INTERNAL DEMOLITION AND CONSTRUCTION ACTIVITIES DUST AND DEBRIS
CONTROL
B. TRAFFIC CONTROL: DESIGNATED ENTRY AND EXIT PROCEDURES SHALL BE
DEFINED. EGRESS PATHS SHALL BE FREE OF DEBRIS; DESIGNATED
ELEVATORS SHALL BE USED DURING SCHEDULED TIMES; AND ONLY
AUTHORIZED PERSONNEL SHALL BE ALLOWED TO ENTER THE
CONSTRUCTION ZONE. SIGNAGE SHALL DIRECT PEDESTRIAN TRAFFIC AWAY
FROM THE CONSTRUCTIOIN AREA AND MATERIALS.
C. CONTRACTOR SHALL USE TWO CARTS TO TRANSFER CONSTRUCTION
MATERIAL AND OUT OF THE PROJECT - CLEAN CART SHALL BE USED; THE
NOT-SO-CLEAN CART SHALL BE USED BETWEEN THE MAIN ENTRY AND THE
CONSTRUCTION STAGING PREP AREA.
D. DEMOLITION DEBRIS: DEBRIS SHALL BE REMOVED IN CARTS WITH TIGHTLY
FITTED COVERS, USING DESIGNATED TRAFFIC ROUTE. EFFORTS SHALL BE
MADE TO MINIMIZE USE OF ELEVATORS WITH AN EMPHASIS ON TRANSPORT
DURING THE LOWEST PERIOD OF ACTIVITY. DEBRIS SHALL BE REMOVED
DAILY AND AT TIMES SPECIFIED BY THE COR. IF CHUTES ARE USED TO
DIRECT DEBRIS OUTSIDE, HIGH EFFICIENCY PARTICULATE AIR (HEPA)
FILTERED NEGATIVE AIR MACHINES SHALL BE USED, AND THE CHUTE
OPENING SHALL BE SEALED WEHN NOT IN USE. FILTERS SHALL BE BAGGED
AND SEALED BEFORE BEING TRANSPORTED OUT OF THE CONSTRUCTION
AAREA. THE CONTRACTOR SHALL NOT HAUL DEBRIS THROUGH PATIENT-
CARE AREAS WITHOUT PRIOR APPROVAL OF THE COR.
E. EXTERIOR WINDOWS: EXISTING WINDOWS SHALL BE PROTECTED TO
PREVENT DAMAGE BY ADJACENT CONSTRUCTION WORK.
VENTILATION AND ENVIRONMENTAL CONTROLS
F. AIR SYSTEM FLOW: THE COR VERIFY AND ACKNOWLEDGE CONTRACTOR
WHETHER THE CONSTRUCTION AREA USES FRESH/OUTSIDE OR RE-
CIRCUATED AIR; FILTERS SHALL BE ADDED OR RETURN VENTS COVERED AS
NEEDED WITH FILTER MATERIAL OR PLASTIC. AIR MUST FLOW FROM CLEAN
TO DIRTY PLACES.
G. NEGATIVE AIR PRESSURE: THE AIR WITHIN THE CONSTRUCTION AREA SHALL
BE NEGATIVE WITH RESPECT TO SURROUNDING AREAS AND WITH NO
DISRUPTION OF AIR SYSTEMS OF ADJACENT AREAS. USE OF THE NEGATIVE
AIR PRESSURE SYSTEM WITHIN THE ENCLOSURE TO REMOVE DUST SHALL
PASS AIR THROUGH AN INDUSTRIAL GRADE PORTABLE HEPA FILTER
CAPABLE OF FILTRATION RATES OF 300-800 CUBIC FEET PER MINUTE
(9FT3/MIN), OR EXHAUST AIR DIRECTLY TO THE OUTSIDE IF APPROVED BY
COR. IF EXHAUST SHALL BE TIED INTO A RE-CIRCULATED AIR SYSTEM, PRE-
FILTER AND HEPA FILTER SHALL BE USED BEFORE EXHAUST TO PREVENT
CONTAMINATION OF THE DUCTS.
H. ADJACENT AREAS: THE STATUS OF SEALED PENETRATIONS AND INTACT
CEILIING SHALL BE VERIFIED DAILY.
I. AIR EXCHANGE RATES AND PRESSURE RELATIONSHIPS: VAMC AND
CONTRACTOR SHALL VERIFY AND MAINTAIN PROPER RATES IN CRITICAL
AREAS NEAR CONSTRUCTION ACTIVITY AND ENSURE AIR IS NOT BEING RE-
CIRCUATED WITHOUT FILTRATION FROM THE CONSTRUCTION AREA
ELSEWHERE. PROVIDE AIR PRESSURE TESTING THOUGHOUT THE PROJECT
IN THE FREQUENCY AS IDENTIFIED BY THE COR.
CONTAMINATION OF PATIENT ROOMS, SUPPLIES, EQUIPMENT AND RELATED
AREAS
J. WORKSITE CLOTHING: CONTRACTOR PERSONNEL CLOTHING SHALL BE
FREE OF LOOSE SOIL AND DEBRIS BEFORE LEAVING THE CONSTRUCTION
AREA. IF PROTECTIVE APPAREL IS NOT WORN (E.G., COVERALLS, FOOTGEAR
AND HEADGEAR) A HEPA-FILTERED VACUUM SHALL BE USED TO REMOVE
DUST FROM CLOTHING BEFORE LEAVING THE BARRICADE. THE
CONTRACTOR SHALL CONSTRUCT AN ANTEROOM FOR CHANGING
CLOTHING AND STORING EQUIPMENT (DESIGNATED AREA. ALL EQUIPMENT,
TOOLS, TOOL CARTS, AND MATERIALS TRANSPORTED THROUGH OCCUPIED
AREAS SHALL BE MADE FREE FROM DUST AND MOISTURE BY VACUUMING
AND WET WIPING BEFORE THEIR REMOVAL FROM THE CONSTRUCTION
ZONE OR WORK AREA.
K. POST CONSTRUCTION: DO NOT REMOVE BARRIERS AND KEEP ALL HVAC
ISOLATION UNTIL CONTRACTOR HAS CLEANED CONSTRUCTION SITE, VA
EMS STAFF HAS DONE A TERMINAL CLEANING, AND VA INFECTIOUS DISEASE
CONTROL HAS INSPECTED AND APPROVED THE CLEANING.
GENERAL
L. PROVIDE TEMPORARY 1-HOUR RATED SLAB-TO-SLAB BARRIERS CONSIST OF
3-5/8" METAL STUD FRAMING WITH 5/8" ON BOTH SIDES. BARRIERS SHALL BE
INSPECTED BY VA PCRA STAFF PRIOR TO START OF CONSTRUCTION IN
SPACE. MAINTAIN NEGATIVE PRESSURE VENTILATION IN THE
CONSTRUCTION SPACE.
M. USE ISOLATION CART FOR ALL WORK IN THIS AREA.
N. PROVIDE TWO STICKY MATS AT EACH CONSTRUCTION ACCESS POINT IN ALL
PHASES.
O. PROVIDE TWO STICKY MATS AT EACH CONSTRUCTION ACCESS POINT IN ALL
PHASES.
P. VA REQUIRES THAT ALL APPLICABLE PERMITS BE COMPLETED AND
APPROVED PRIOR TO BEGINNING ANY WORK ON STATION.
PERMITS INCLUDE:
ICRA, PCRA, ILSM, ABOVE CEILING, FIRE/SMOKE
WALL, UTILITY, FIRE SPRINKLER, FIRE ALARM SYSTEM, MEDICAL GASES,
CONFINED SPACE AND HOT WORK.
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:3
P
M
G-103
INFECTION CONTROL RISK
ASSESSMENT DETAILS (ICRA)
4 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
Scale: No Scale
ICRA DETAILS
CJCJ
CJ
CJ
CJ
CJ
CJ
EJ
EJ
FD
CSWK 9CSWK 9
GP17
TB(3)
TB(22)
HEATING STRIP
FEC
W A
LL
20.5 20 1515.816171819
E
G
H
I
J
G.3
F.8
F.5
E.8
E.5
EXIS
TIN
G
EXPA
N
SIO
N
JO
IN
T
E X
IS
T
IN
G
X P
A N
S
IO
N J
O
IN
T
GEN. EXAM
1A-805
MEDS
1A-804
PSYCH EXAM
1A-796
ANTE ROOM
1A-795
ISOLATION
EXAM
1A-794
WHEELCHAIR
SHOWER
1A-808
TREATMENT
BAY
IA-807 EQUIPMENT
STORAGE
1A-773
TLT
1A-768A
EXAM 3
1A-768
EXAM 4
1A-767
EXAM 5
1A-766
EXAM 10
1A-780
EXAM 9
1A-779
EXAM 8
1A-778
EXAM 7
1A-777
EXAM 11
1A-782
EXAM 12
1A-783
EXAM 13
1A-784
EXAM 14
1A-785
PAT. TLT
1A-786
TOILET
ROOM
1A-793
TOILET
ROOM
1A-792
GYN. EXAM
1A-791
STORAGE
1A-790A
LINEN
1A-772A
WORK RM
1A-772
WAITING
C1A-765
TRIAGE
1A-761
TRIAGE
1A-762
TRIAGE
1A-763
TRIAGE
1A-759
TRIAGE
1A-758
PAT. TOILET
1A-740
EKG
1A-739
FAST TRACK
1A-738
FAST TRACK
1A-737
FAST TRACK
1A-736 PHYSICIANS
WORKROOM
1A-719
EXAM 4
1A-718
EXAM 3
1A-717
EXAM 2
1A-716
EXAM 1
1A-715
EMS
1A-714
VITAL SIGNS
1A-713 EXAM 5
1A-724
EXAM 10
1A-726
EXAM 11
1A-727
EXAM 12
1A-728
EXAM 13
1A-729
EXAM 14
1A-730
EXAM 9
1A-720
EXAM 8
1A-721
EXAM 7
1A-722
EXAM 6
1A-723
MEN'S
RESTROOM
1A-734
WOMEN'S
RESTROOM
1A-733
TRANSFER
COORDINATORS
1A-802
BED
CONTROL
1A-802A
VISC ESCORT
1A-800
CLERK
WORKROOM
1A-704
VIC
1A-705
Room
MEAN'S
TEST.
1A-707
MEAN'S
TEST.
1A-708
SOC.
WORKER
1A-742
OFFICE
1A-743
TLT
1A-745
MED. DIR
1A-751
ADMIN. ASST.
1A-750
NURSE
1A-749
CODER
OFFICE
1A-748 CONF ROOM
1A-746
BED
CONTROL
1A-711
BED
CONTROL
1A-710
OFFICE
1A-200E
WALK-IN
VESTIBULE
C1A-754
POLICE
1A-756
AMBULANCE
VESTIBULE
C1A-811
ISOLATION
1A-813
BED 4
BED 3
BED 2
BED 1
ASSISTED
CARE
1A-812
MEDS
1A-814
CORRIDOR
C1A-810
RECEPTION
1A-757
CORRIDOR
C1A-764
CORRIDOR
C1A-764A
TRIAGE
WORK
1A-760
EXAM 18
1A-790
EXAM 17
1A-789
EXAM 16
1A-788
EXAM 15
1A-787
NURSE
CONTROL
1A-799
STAFF/PHYS.
WORKSTATIONS
1A-798
Room
ADMISSIONS
CLERK
1A-775
NOURISHMENT
1A-781
GERIATRIC
CLERK
1A-712
REGISTRATION
CLERK
1A-709
CORRIDOR
1A-741A
CORRIDOR
1A-741B
Room 1A-741C
COPY
1A-747
STOR. RM
1A-744
CORRIDOR
C1A-735
CORRIDOR
C1A-732
CORRIDOR
C1A-725
CORRIDOR
C1A-774
CORRIDOR
C1A-776
CORRIDOR
C1A-801
CORRIDOR
C1A-800
CORRIDOR
C1A-802
STRETCHER
C1A-809
CORRIDOR
C1A-731
GERIATRIC
WAITING
C1A-702
REGISTRATION
WAITING
C1A-701
ER/URGENT
CARE
WAITING
C1A-703
PHASE 1A
PHASE 2B
PHASE 2B
PHASE 2A
LIMITS
OF WORK
18.9
PHASE 1B
CHASE
ELEVATOR
PHASE 2B
3 8
S
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:4
P
M
GC101
FIRST FLOOR PHASING PLAN -
EXISTING
5 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
Scale: 1/8" = 1'-0"
FIRST FLOOR EXISTING PLAN - FOR INFORMATION ONLY
1. SHEET GC101 PROVIDED FOR INFORMATION
ABOUT EXISTING CONDITIONS.
2. REFER TO SHEET GC102 FOR PHASING PLAN.
3. REFER TO SHEET GC103 FOR DEDUCT ALTERNATE
PLAN.
1 PHASE 1A (4873 SF) – RENOVATE MAJORITY OF
EXPANSION SPACE. THE EXISTING FAST TRACK
AREA MUST REMAIN OPERATIONAL DURING THIS
TIME, ACCESSED BY THE DOOR CONSTRUCTED
IN PHASE 1A.
2 PHASE 1B (1013 SF) - ADD ONE ADDITION EXAM
ROOM, ONE CLEAN STORAGE ROOM, STAFF
TOILET, INTERVIEW ROOM, MEDICATION
STORAGE, AND ALCOVE SPACE.
3 PHASE 2A (63 SF) - RENOVATE FOR TWO EXAM
ROOMS 1A-794 AND 1A791 AND TOILETS. 1A-793
AND STORAGE 1A-990A TO BE ANTE ROOMS FOR
NEW ISOLATION EXAM ROOMS.
4 DEDUCTIVE ALTERNATE 1 - ELIMINATE THE
SWITCHABLE GLASS FOR THE EXAM ROOM
SLIDING DOORS AND ADD CUBICLE CURTAINS.
5 DEDUCTIVE ALTERNATE 2 - ELIMINATE PHASE 2B ,
RESUSCITATION ROOM AND NEW MEDICATION
STORAGE, WORK FROM PROJECT SCOPE OF
WORK.
6 DEDUCTIVE ALTERNATE 3 - ELIMINATE EXAM
ROOM SLIDING DOORS. ADD CUBICAL CURTAINS
IN L-SHAPE. CONTRACTOR TO PROVIDE A UNIT
PRICE FOR SLIDERS VS. CURTAIN/DOOR AND
FRAME.
7 PHASE 2B (341 SF) RENOVATE FOR ONE NEW
RESUSCITATION ROOM. REMOVE THE WALL
BETWEEN WORK ROOM 1A-772 AND LINEN
1A-772A CREATING ONE SPACE, NEW MEDS
STORAGE 1A-804.
8 ADD NEW DOOR OPENING, FRAME, DOOR AND
HARDWARE BETWEEN EXISTING ISOLATION
ROOM AND EXISTING TOILET ROOM.
# SHEET KEY NOTES:
A
A
CJCJ
CJ
CJ
CJ
CJ
CJ
EJ
EJ
FD
CSWK 9CSWK 9
GP17
TB(3)
TB(22)
HEATING STRIP
FEC
W A
LL
A A
A
20.5 20 1515.816171819
E
G
H
I
J
G.3
F.8
F.5
E.8
E.5
PHASE 1A
PHASE 1B
PHASE 2A
PHASE 2B
Calculating...
4873 SF
PHASE 1A
77 SF
PHASE 2B
50 SF
PHASE 2A13 SF
PHASE 2A
264 SF
PHASE 2B
1013 SF
PHASE 1B
1 4
1 4
1 4
Room
1 4
1 4
LIMITS OF WORK
18.9
ELEVATOR
CHASE
CR
PB
PB
PB
CR
CR
PB
CR
5 7
161 SF
PHASE 2B
EGRESS PATH
EGRESS PATH TAG
EGRESS PATH TAG -
COMMON PATH
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER BRACKET
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
EMERGENCY RESPONSE
REFERENCE
CONTROLLED ACCESS -
ALWAYS UNLOCKED IN
DIRECTION OF EGRESS
KNOX BOX
DELAYED EGRESS W/ ALARM
SMOKE COMPARTMENTS
(MAX 40,000 SF
PER NFPA 101.21.3.7.2
ABD 19.3.7.1)
CARD READER
PUSH BUTTON
CA
DE
KB
XXX
XXX
FEB
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH EGRESS
CAPACITY
CR
PB
S
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:1
P
M
GC102
FIRST FLOOR PHASING PLAN - OVER
NEW
6 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
Scale: 1/8" = 1'-0"
FIRST FLOOR PHASING PLAN
1 PHASE 1A (4873 SF) – RENOVATE MAJORITY OF
EXPANSION SPACE. THE EXISTING FAST TRACK
AREA MUST REMAIN OPERATIONAL DURING THIS
TIME, ACCESSED BY THE DOOR CONSTRUCTED
IN PHASE 1A.
2 PHASE 1B (1013 SF) - ADD ONE ADDITION EXAM
ROOM, ONE CLEAN STORAGE ROOM, STAFF
TOILET, INTERVIEW ROOM, MEDICATION
STORAGE, AND ALCOVE SPACE.
3 PHASE 2A (63 SF) - RENOVATE FOR TWO EXAM
ROOMS 1A-794 AND 1A791 AND TOILETS. 1A-793
AND STORAGE 1A-990A TO BE ANTE ROOMS FOR
NEW ISOLATION EXAM ROOMS.
4 DEDUCTIVE ALTERNATE 1 - ELIMINATE THE
SWITCHABLE GLASS FOR THE EXAM ROOM
SLIDING DOORS AND ADD CUBICLE CURTAINS.
5 DEDUCTIVE ALTERNATE 2 - ELIMINATE PHASE 2B ,
RESUSCITATION ROOM AND NEW MEDICATION
STORAGE, WORK FROM PROJECT SCOPE OF
WORK.
6 DEDUCTIVE ALTERNATE 3 - ELIMINATE EXAM
ROOM SLIDING DOORS. ADD CUBICAL CURTAINS
IN L-SHAPE. CONTRACTOR TO PROVIDE A UNIT
PRICE FOR SLIDERS VS. CURTAIN/DOOR AND
FRAME.
7 PHASE 2B (341 SF) RENOVATE FOR ONE NEW
RESUSCITATION ROOM. REMOVE THE WALL
BETWEEN WORK ROOM 1A-772 AND LINEN
1A-772A CREATING ONE SPACE, NEW MEDS
STORAGE 1A-804.
8 ADD NEW DOOR OPENING, FRAME, DOOR AND
HARDWARE BETWEEN EXISTING ISOLATION
ROOM AND EXISTING TOILET ROOM.
A. WORK FOR THE PROJECT SHALL BE PHASED TO
ALLOW THE VA TO MAINTAIN OPERATIONS OF THE
EMERGENCY DEPARTMENT AT ALL TIMES DURING
THE COMPLETE LIFE OF THE PROJECT, DURING
BOTH DEMOLITION AND CONSTRUCTION FOR
EACH PHASE.
B. AT THE START OF EACH PHASE, PROVIDE
INFECTION CONTROL MEASURES INCLUDING
TEMPORARY PARTITIONS, CONSTRUCTION
ACCESS ANTEROOMS, HEPA-FILTERED EXHAUST,
AND USE OF MOBILE CONTAINMENT CARTS PER
ICRA REQUIREMENTS TO PREVENT THE SPREAD
OF DUST AND CONTAMINANTS TO ADJACENT
OCCUPIED AREAS. MAINTAIN INFECTION
CONTROL MEASURES AT ALL TIMES THROUGH
THE COMPLETE LIFE OF THE PROJECT. REFER TO
G-103 FOR STANDARD INFECTION CONTROL
MEASURES.
PHASING LEGEND
LEGEND
# SHEET KEY NOTES:
A
CJ
CJCJ
CJ
CJ
CJ
CJ
CJ
EJ
EJ
FD
CSWK 9CSWK 9
GP17
TB(3)
TB(22)
HEATING STRIP
FEC
W A
LL
A A
A
EGRESS PATH
EGRESS PATH TAG
EGRESS PATH TAG -
COMMON PATH
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER BRACKET
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
EMERGENCY RESPONSE
REFERENCE
CONTROLLED ACCESS -
ALWAYS UNLOCKED IN
DIRECTION OF EGRESS
KNOX BOX
DELAYED EGRESS W/ ALARM
SMOKE COMPARTMENTS
(MAX 40,000 SF
PER NFPA 101.21.3.7.2
ABD 19.3.7.1)
CARD READER
PUSH BUTTON
CA
DE
KB
XXX
XXX
FEB
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH EGRESS
CAPACITY
CR
PB
20.5 20 1515.816171819
E
G
H
I
J
G.3
F.8
F.5
E.8
E.5
AE301
AE301
AE411
AE411
AE411
AE411
AE411
9 10
AE411
AE411
AE411
AE411
18.9
LIMITS
OF WORK
1 4 6
1 4 6
1 4 6
1 4 6
1 4 6
1 4 6
1 4 6
1 4 6
1 4 6
1 4 6
1 4 6
S
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:2
P
M
GC103
FIRST FLOOR PHASING PLAN - OVER
NEW - DEDUCTIVE ALTERNATES
7 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
1 PHASE 1A (4873 SF) – RENOVATE MAJORITY OF
EXPANSION SPACE. THE EXISTING FAST TRACK
AREA MUST REMAIN OPERATIONAL DURING THIS
TIME, ACCESSED BY THE DOOR CONSTRUCTED
IN PHASE 1A.
2 PHASE 1B (1013 SF) - ADD ONE ADDITION EXAM
ROOM, ONE CLEAN STORAGE ROOM, STAFF
TOILET, INTERVIEW ROOM, MEDICATION
STORAGE, AND ALCOVE SPACE.
3 PHASE 2A (63 SF) - RENOVATE FOR TWO EXAM
ROOMS 1A-794 AND 1A791 AND TOILETS. 1A-793
AND STORAGE 1A-990A TO BE ANTE ROOMS FOR
NEW ISOLATION EXAM ROOMS.
4 DEDUCTIVE ALTERNATE 1 - ELIMINATE THE
SWITCHABLE GLASS FOR THE EXAM ROOM
SLIDING DOORS AND ADD CUBICLE CURTAINS.
5 DEDUCTIVE ALTERNATE 2 - ELIMINATE PHASE 2B ,
RESUSCITATION ROOM AND NEW MEDICATION
STORAGE, WORK FROM PROJECT SCOPE OF
WORK.
6 DEDUCTIVE ALTERNATE 3 - ELIMINATE EXAM
ROOM SLIDING DOORS. ADD CUBICAL CURTAINS
IN L-SHAPE. CONTRACTOR TO PROVIDE A UNIT
PRICE FOR SLIDERS VS. CURTAIN/DOOR AND
FRAME.
7 PHASE 2B (341 SF) RENOVATE FOR ONE NEW
RESUSCITATION ROOM. REMOVE THE WALL
BETWEEN WORK ROOM 1A-772 AND LINEN
1A-772A CREATING ONE SPACE, NEW MEDS
STORAGE 1A-804.
8 ADD NEW DOOR OPENING, FRAME, DOOR AND
HARDWARE BETWEEN EXISTING ISOLATION
ROOM AND EXISTING TOILET ROOM.
A. WORK FOR THE PROJECT SHALL BE PHASED TO
ALLOW THE VA TO MAINTAIN OPERATIONS OF
THE EMERGENCY DEPARTMENT AT ALL TIMES
DURING THE COMPLETE LIFE OF THE PROJECT,
DURING BOTH DEMOLITION AND
CONSTRUCTION FOR EACH PHASE.
B. AT THE START OF EACH PHASE, PROVIDE
INFECTION CONTROL MEASURES INCLUDING
TEMPORARY PARTITIONS, CONSTRUCTION
ACCESS ANTEROOMS, HEPA-FILTERED
EXHAUST, AND USE OF MOBILE CONTAINMENT
CARTS PER ICRA REQUIREMENTS TO PREVENT
THE SPREAD OF DUST AND CONTAMINANTS TO
ADJACENT OCCUPIED AREAS. MAINTAIN
INFECTION CONTROL MEASURES AT ALL TIMES
THROUGH THE COMPLETE LIFE OF THE
PROJECT. REFER TO G-103 FOR STANDARD
INFECTION CONTROL MEASURES.
C. REFER TO GC102 FOR PHASING PLAN.
# SHEET KEY NOTES:
LEGEND
1/8" = 1'-0"
FIRST FLOOR DEDUCT ALTERNATE PLAN - NEW
T-5
M7250
R7000 M3150 M3150 R7000
M
M
F0535 F0535
C1A-101
VEST
C
RASH C
ART
STRETC
HER
TRASHCONDUMENTS
COUNTER CABINET
COUNTERPASTRY
CJ
FFC
CJ FFC
FFC
CRCR
FFC
CJ
CJCJCJCJCJCJCJ
FFC
CJ
CJ
CJ
FFC
CJ
CJ
CJ
CJ
CJ
CJ
FFC
CJFFC
FFC
CJ
CJ
CJ
CJ
FFC FFC
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ CJ CJ CJ CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
FFC
CJ
FFC
EXAM TABLE
EXAM TABLE
EXAM TABLE
EXAM TABLE
ADMIN ASST
MEDICATION RM.
CONS
1A-276A
DIETICIAN
SECY.
TMT/WAIST
MED & TMT
PROCPROC
EKG
COPY RM.
CONS
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
FD
FD
FD FD
BELOW
FD
BELOW
BELOWBELOW
FD
FD
FD
FD
FDFD
FD
FD FD
FDFD
FD
FD
FDFD
FD FD
FDFDFD
FD FD FD
FD
FD FD
FD
FD
4" CONC PAD
FD FD FD
FD
FD FD
FD
FDFD FD
FD FD
FD
FD FD
FDFDFD
FD
FD
FD
FD
FDFD
FD FD
FD FDFD
FD
FD
FDFDFD
FD FD FD
FD
FD
FD
FD
FD
FD
FDFD
FD
FD
FD
CSWK 9
4" CONC PAD
4" CONC PAD
T37(3)
DISPLAY CAB
CSWK41
T22E
FIAO4(VV)
T6(4)
VL3-24
GMA151
TOP 10B
FIN ENDS
VL31-36(3)(L)
VL4-36(3)(L)
TOP 10B
FIA01 (VV)
FTG38
TC (12)
FIN END
4" RAD.
CSWH4
GPB
4" CONC PAD
TC14
TB(3)
TB(8)
CSWK 51
CABINET
ROLLING
CART
T7B(2)
TD(17)
TD(6)
CSWK 51
CSWK 2
SIM FIN END
T6B(2)
T35 (2)
4" CONC PAD
CSWK 52
FHVEC
VL4-30 T5C(2)
T6AT6B (2)
T6A
T18C3
CSWK 52
4" CONC. PAD
CSWK 9
4" CONC PAD
GP17
TB(3)
TB(22)
T7 T-10
4" CONC PAD
TD(22)TD(22)
1 1
HEATING STRIP
TV
PAC
MAN
TV FOR
GAMES
TV FOR
MOVIES
FEC
REF
PRINTER
COPIER
GP35
GP35
GP35
GP26
Z1P01
CSWK
Z1J02
Z1E01
Z1E04
Z1E02E
Z1E01E
Z1E10
Z1E02
Z1A02A Z1A01A
Z1K01
Z1K02
Z1K03
Z1K04
Z1K05
Z 1G
Z1G04
Z1G02
Z1G03
Z1G05
Z1H01 Z1F01
Z1F05 Z1F06 Z1F07
Z1F01F
Z1F10
Z 1F
W
AL
L
UPS FEDX
FD
w c wc wc
E
D C C
AWAY FROM DIRECT
SUNLIGHT
FOR USE IN
AC ENVIRONMENT
ONLY
24238 SF
EXISTING
AMBULATORY
HEALTH CARE
OCCUPANCY
21025 SF
EXISTING
SMOKE
COMPARTMENT
H
11933 SF
EXISTING
SMOKE
COMPARTMENT
M
22885 SF
EXISTING
SMOKE
COMPARTMENT
D
21859 SF
EXISTING
SMOKE
COMPARTMENT
C
23541 SF
EXISTING
SMOKE
COMPARTMENT
B
21837 SF
EXISTING
SMOKE
COMPARTMENT
A
13837 SF
EXISTING
SMOKE
COMPARTMENT
135445
SF
EXISTING
BUSINESS
OCCUPANCY
7687 SF
EXISTING
SMOKE
COMPARTMENT
L
LIMITS OF WORK
EXISTING AMBULATORY HEALTH CARE
OCCUPANCY
EXISTING BUSINESS OCCUPANCY
EXISTING SMOKE COMPARTMENT
EXISTING SMOKE COMPARTMENT A
EXISTING SMOKE COMPARTMENT B
EXISTING SMOKE COMPARTMENT C
EXISTING SMOKE COMPARTMENT D
EXISTING SMOKE COMPARTMENT H
EXISTING SMOKE COMPARTMENT L
EXISTING SMOKE COMPARTMENT M
GL102
EGRESS PATH
EGRESS PATH TAG
EGRESS PATH TAG -
COMMON PATH
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER BRACKET
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
EMERGENCY RESPONSE
REFERENCE
CONTROLLED ACCESS -
ALWAYS UNLOCKED IN
DIRECTION OF EGRESS
KNOX BOX
DELAYED EGRESS W/ ALARM
SMOKE COMPARTMENTS
(MAX 40,000 SF
PER NFPA 101.21.3.7.2
ABD 19.3.7.1)
CARD READER
PUSH BUTTON
CA
DE
KB
XXX
XXX
FEB
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH EGRESS
CAPACITY
CR
PB
S
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:4
P
M
GL101
OVERALL FIRST FLOOR LIFE SAFETY
PLAN
8 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
Scale: 1/32" = 1'-0"
FIRST FLOOR LIFE SAFETY - OCCUPANCY AND SMOKE COMPARTMENTS
THE LIFE SAFETY PLAN RECEIVED BY APOGEE CONSULTING GROUP INDICATES THE
SMOKE COMPARTMENTS ILLUSTRATED BELOW. BASED ON THESE SMOKE
COMPARTMENTS AND THE 2-HOUR FIRE BARRIER LOCATIONS SHOWN ON THE SAME
RECEIVED LIFE SAFETY PLAN, IT IS BELIEVED THAT THE EXISTING EMERGENCY
DEPARTMENT AND EXPANSION SPACE ARE ALREADY PART OF THE HEALTHCARE
OCCUPANCY. WITH THIS ASSUMPTION, MOST WALL RATINGS OF THE FACILITY ARE
CORRECT IN THEIR CURRENT STATE.
COMPARTMENT LEGEND
C1A-101
VEST
CJ
CJCJCJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
EJ
EJ
FD
FD
FD
FD
FD
FD FDFDFD
FDFDFD
FD FD FD
FD
FD
FD
FD
FD
FD
FD
CSWK 9CSWK 9
GP17
TB(3)
TB(22)
T7 T-10
HEATING STRIP
FEC
Z1K01
Z1K02
Z1K03
Z 1G
Z1G02
W
AL
L
UPS FEDX
24238 SF
EXISTING
AMBULATORY
HEALTH CARE
OCCUPANCY
7687 SF
EXISTING
SMOKE
COMPARTMENT
L
LIMITS OF WORK
CAPACITYCLR
72" 360
CAPACITYCLR
36" 180
CAPACITYCLR
36" 180
CAPACITYCLR
72" 360
EXISTING 2-HR
SEPARATION
EXISTING 2-HR
SEPARATION
EXISTING 2-HR
SEPARATION
EXISTING 2-HR
SEPARATION
EXISTING AMBULATORY HEALTH CARE
OCCUPANCY
EXISTING BUSINESS OCCUPANCY
EXISTING SMOKE COMPARTMENT H
EXISTING SMOKE COMPARTMENT L
FEC
FEC
VERTICAL SHAFTS
(per IBC 39.3.1)
EGRESS WIDTH
(per IBC 1009.2, 1018.2)
COMMON PATH OF TRAVEL
(per IBC 1014)
EXIT ACCESS TRAVEL DATA
(per IBC 21.2.6, 7.7.2, 7.6)
DEAD-END CORRIDOR
(per IBC 1018.4)
STAIR ENCLOSURES
(per IBC XX - XX)
1 HR RATED
STAIRWAYS - 44"
EGRESS COMPONENTS - 44"
100 IF IN SUITE
NOT MORE THAN 50% OF REQ. NUMBER OF EXITS
50 FEET
1 HR RATED
OCCUPANT LOAD
(per NFPA 7.3.1.2, IBC 1004.1.1)
150 AMBULATORY CARE
TRAVEL DISTANCE
(per IBC 1016.1)
TRAVEL DISTANCE BETWEEN ROOM DOOR AND
EXIT ACCESS SHALL NOT EXCEED 200 FEET WITH
SPRINKLER SYSTEM
EGRESS PATH
EGRESS PATH TAG
EGRESS PATH TAG -
COMMON PATH
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER BRACKET
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
EMERGENCY RESPONSE
REFERENCE
CONTROLLED ACCESS -
ALWAYS UNLOCKED IN
DIRECTION OF EGRESS
KNOX BOX
DELAYED EGRESS W/ ALARM
SMOKE COMPARTMENTS
(MAX 40,000 SF
PER NFPA 101.21.3.7.2
ABD 19.3.7.1)
CARD READER
PUSH BUTTON
CA
DE
KB
XXX
XXX
FEB
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH EGRESS
CAPACITY
CR
PB
A. REFER TO SHEET AG001 FOR ABBREVIATIONS..
B. REFER TO PLUMBING DRAWINGS FOR
INFORMATION CONCERNING PLUMBING
FIXTURES AND PIPING SYSTEM(S).
C. REFER TO MECHANICAL DRAWINGS FOR
INFORMATION CONCERNING HVAC SYSTEM(S).
D. REFER TO ELECTRICAL DRAWINGS FOR
INFORMATION CONCERNING POWER, LIGHTING
AND COMMUNICATION SYSTEM(S).
E. REFER TO FIRE ALARM DRAWINGS FOR FIRE
ALARM NOTIFICATION AND EMERGENCY EGRESS
LIGHTING LOCATIONS.
F. REFER TO PARTITION TYPES FOR FURTHER FIRE
SEPARATION REQUIREMENTS.
G. PROVIDE ALL ADDITIONAL FRAMING NECESSARY
FOR ALL OPENINGS AND SUPPLEMENTAL
FRAMING ABOVE PARTITIONS.
H. ALL FIRE RATED ASSEMBLIES SHALL BE
INSTALLED IN ACCORDANCE WITH TESTED
ASSEMBLIES INDICATED.
I. EXTEND FIRE RATED PARTITIONS, BARRIERS,
AND OTHER SEPARATIONS TO BOTTOM OF
FLOOR DECK ABOVE (OR AS DIRECTED BY UL
ASSEMBLY). SEAL JOINT BETWEEN EDGES OF
PARTITION WITH FIRE RATED SEALANT AND/OR
INTUMESCENT ASSEMBLY.
J. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES
SHALL BE FIRE-SEALED IN ACCORDANCE WITH
APPROVED MANUFACTURER'S DETAIL FOR
LOCATION, TYPE OF CONSTRUCTION,
PENETRATING ITEM AND RATING REQUIRED.
K. ALL DUCTWORK, DIFFUSERS AND GRILLES
PENETRATING FIRE-RATED WALLS, CEILINGS
AND FLOORS SHALL HAVE THE APPROPRIATE
TYPE OF FIRE/SMOKE DAMPER IN ACCORDANCE
WITH THE TYPE OF CONSTRUCTION BEING
PENETRATED AND THE FIRE/SMOKE RATING
REQUIRED.
L. ALL LIGHT FIXTURES AND ELECTRICAL DEVICES
PENETRATING FIRE-RATED ASSEMBLIES SHALL
BE UL-LISTED FOR INSTALLATION IN THE
ASSEMBLY OR SHALL BE INSTALLED SUCH THAT
THE FIRE-RATING IS NOT COMPROMISED.
M. SMOKE RESISTANT CONSTRUCTION SHALL MEET
THE REQUIREMENTS OF ALL APPLICABLE
CODES. AREA SHALL BE SEPARATED FROM THE
REMAINDER OF THE BUILDING BE
CONSTRUCTION CAPABLE OF RESISTING THE
PASSAGE OF SMOKE. THE PARTITIONS SHALL
EXTEND FROM THE FLOOR TO THE UNDERSIDE
OF THE FLOOR OR ROOF ASSEMBLY ABOVE.
DOORS SHALL BE SELF OR AUTOMATIC
CLOSING. DOORS SHALL NOT HAVE AIR
TRANSFER OPENINGS AND SHALL NOT BE
UNDERCUT IN EXCESS OF CLEARANCE
PERMITTED WITH ACCORDANCE TO NFPA 80.
N. STORAGE OF ANY FLAMMABLE OR
COMBUSTIBLE LIQUIDS IS UNDERSTOOD TO NOT
BE WITHIN THE BUILDING. STORAGE OF ANY
MATERIAL IS TO BE IN COMPLIANCE WITH ALL
APPLICABLE CODES AND AUTHORITIES HAVING
JURISDICTION.
S
TAT E O F N E VA
D A
T H
E O
D
ORE JOHN MOW
EN
JRR
EG
ISTERED
No. 7867
A R C H I T E C
T
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:1
P
M
GL102
FIRST FLOOR LIFE SAFETY PLAN
9 9TM HM
HOUSTON VAMC ED
EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
March 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
Scale: 1/16" = 1'-0"
LIFE SAFETY PLAN - EGRESS
PROPOSED USE:
OWNED BY: PRIVATE
LOCAL GOVERNMENT
CITY/COUNTY
STATE
CODE ENFORCEMENT JURISDICTION: CITY
COUNTY
APPLICABLE CODES:
GENERAL CODE INFORMATION:
NEW CONSTRUCTION
RENOVATION (EXISTING BUILDING)
CONSTRUCTION TYPE:
MIXED CONSTRUCTION
SPRINKLERED
MEZZANINE
MIXED OCCUPANCY
PRIMARY OCCUPANCY:
SECONDARY OCCUPANCY:
PROJECT NAME:
PROJECT ADDRESS:
OWNER OR AGENT:
TYPE I
HEALTHCARE
STORAGE
NFPA 1 FIRE CODE: 2018
ADA: 2010
NFPA 10 PORTABLE FIRE EXTINGUSIHER: 2018
NFPA 13 FIRE SPRINKLER SYSTEM: 2016
NFPA 70 NATIONAL ELECTRIC CODE: 2017
NFPA 99 HEALTH CARE FACILITY. CODE: 2018
INTERNATIONAL BUILDING CODE: 2018
NFPA 101 LIFE SAFETY CODE: 2018
PG-18-13 BARRIER FREE DESIGN: 2017
ABA-ARCH. BARRIERS ACT: 20##
INTERNATIONAL EXISTING BUILDING CODE: 2018
HOUSTON VAMC ED EXPANSION
Michael E. DeBakey VA Medical Center 2002 Holcombe Blvd. Houston, TX 77030
Department of Veterans Affairs
CODE INFORMATION
FEDERAL
LEGEND
- MAX TRAVEL DISTANCE COMMON PATH WITHIN A
SUITE 100 LF.
COMPARTMENT LEGEND
EGRESS DATA:
| Sheets |
| G-001 - COVER SHEET |
| G-100 - GENERAL INFORMATION |
| G-102 - PRE CONSTRUCTION RISK ASSESSMENT (PCRA) |
| G-103 - INFECTION CONTROL RISK ASSESSMENT DETAILS (ICRA) |
| GC101 - FIRST FLOOR PHASING PLAN - EXISTING |
| GC102 - FIRST FLOOR PHASING PLAN - OVER NEW |
| GC103 - FIRST FLOOR PHASING PLAN - OVER NEW - DEDUCTIVE ALTERNATES |
| GL101 - OVERALL FIRST FLOOR LIFE SAFETY PLAN |
| GL102 - FIRST FLOOR LIFE SAFETY PLAN |
| 2019-03-14T11:34:16-0700 | |
| Digitally verifiable PDF exported from www.docusign.com |
File details come from the government source that posted it.