36C25619R0072-007.pdf

PDF 744 KB Posted

Attached to
NRM 580-17-101 Expand - Renovate ER
Solicitation number
36C25619R0072
Issued by

About this file

36C25619R0072 580-17-101 Project Drawings - Fire Alarm.pdf

View the file

Other files

File Type Posted
36C25619C0088-000.docx DOCX document
36C25619R0072-0003002.pdf PDF
36C25619R0072-0003000.docx DOCX document
36C25619R0072-0003001.pdf PDF
36C25619R0072-0002000.docx DOCX document
36C25619R0072-0002001.docx DOCX document
36C25619R0072-0001003.pdf PDF
36C25619R0072-0001002.pdf PDF
36C25619R0072-0001004.pdf PDF
36C25619R0072-0001001.pdf PDF
36C25619R0072-0001000.docx DOCX document
36C25619R0072-003.pdf PDF
36C25619R0072-004.pdf PDF
36C25619R0072-009.pdf PDF
36C25619R0072-013.pdf PDF
36C25619R0072-011.pdf PDF
36C25619R0072-006.pdf PDF
36C25619R0072-008.pdf PDF
36C25619R0072-005.pdf PDF
36C25619R0072-001.docx DOCX document
36C25619R0072-010.pdf PDF
36C25619R0072-002.docx DOCX document
36C25619R0072-012.docx DOCX document
36C25619R0072-000.docx DOCX document
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE ALARM SYMBOL LEGEND

FIRE ALARM PULL STATION

SYMBOL HEIGHT DESCRIPTION

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

TOP: HEIGHT TO TOP OF DEVICE

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

F

F

S

FIRE ALARM SPEAKER

FIRE ALARM STROBE

FIRE ALARM PULL SPEAKER AND STROBE

FIRE ALARM DOOR OPEN HOLDER

FIRE ALARM SMOKE DETECTOR

FIRE ALARM CEILING MOUNTED SPEAKER

P

FIRE ALARM DUCT SMOKE DETECTOR

FIRE ALARM HEAT DETECTOR

48"

90"

90"

90"

FIRE ALARM PANEL

FIRE ALARM NAC PANEL

FIRE ALARM ANNUNCIATOR PANEL

FLOW SWITCH

FAP

NAC

FAAP

TAMPER SWITCH

POST INDICATOR VALVEPIV

REMOTE LIGHT/TEST SWITCH FOR DUCT DETECTORS

F FIRE ALARM BELL90"

XX - CANDELA

XX - CANDELA

XX - WATTAGEF

S

F S

H

GENERAL FIRE ALARM NOTES

1. PROVIDE FIRE ALARM SYSTEM AND COMPONENTS COMPLYING WITH:

A. NFPA 13- STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.

B. NFPA 14- STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEM.

C. NFPA 20- STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION.

D. NFPA 70 NATIONAL ELECTRICAL CODE.

E. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE.

F. NFPA 90A STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS.

G. NFPA 101 LIFE SAFETY CODE.

H. VA FIRE PROTECTION DESIGN MANUAL.

I. ANSI S3.41 AUDIBLE EMERGENCY EVACUATION SIGNAL.

J. NFPA 88A STANDARD FOR PARKING STRUCTURES.

1. FIRE ALARM SYSTEM SHALL COMPLY WITH FACTORY MUTUAL RESEARCH CORPORATION (FM).

2. PROVIDE FIRE ALARM WIRING IN CONDUIT, FACTORY PAINTED RED.

3. BEFORE STARTING WORK, TEST EXISTING FIRE ALARM SYSTEM IN WORK AREA AND ADJACENT AREAS.

4. NOTIFY CONTRACTING OFFICER'S REPRESENTIVE REGARDING DEFICIENCIES AND NON-OPERATING

OMPONENTS. VA WILL MAKE REPAIRS.

5. WHEN WORK IS COMPLETE, TEST EXISTING FIRE ALARM SYSTEM IN WORK AREA AND ADJACENT AREAS.

6. MAKE REPAIRS TO RESOLVE INCORRECT SYSTEM OPERATIONS AT NO ADDITIONAL COST.

7. THE FIRE ALARM SYSTEM VENDOR/CONTRACTOR SHALL TERMINATE, TEST AND PROGRAM ALL NEW FIRE

ALARM DEVICES. COORDINATE WITH COR.

8. CONNECT SPRINKLER SYSTEM SUPERVISORY DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE

LOCATION WITH THE SPRINKLER CONTRACTOR.

9. PROVIDE RELAY CONTROL MODULES FOR PACS, COORDINATE WITH PHYSICAL ACCESS CONTROL SYSTEM

(PACS), CONTRACTOR AND COR.

NOTES:

1. FIRE ALARM SYSTEM SHALL BE INTERCONNECTED

WITH ACCESS CONTROL SYSTEM TO ALLOW EGRESS

DURING ALARM CONDITIONS. COORDINATE BETWEEN

ACCESS CONTROL SYSTEM AND FIRE ALARM SYSTEM

MANUFACTURERS.

2. ALL FIRE ALARM WIRING SHALL BE IN FACTORY

PAINTED "RED" EMT CONDUIT.

3. ALL WIRING SHALL BE AS RECOMMENDED BY

MANUFACTURER.

4. PROVIDE SEPERATE OUTPUT SIGNALS TO AIR

HANDLER UNIT VFD FOR INDIVIDUAL UNIT SHUT-

DOWN.

5. PROVIDE ZONE ADAPTER MODULES TO CONNECT

NON ADDRESSABLE DEVICES SUCH AS FLOW AND

TAMPER SWITCHES, DOOR HOLD-OPEN DEVICES, AND

CONTROL SIGNALS.

6. PROVIDE POWER SUPPLY AND/OR NAC

(NOTIFICATION APPLIANCE CIRCUIT) PANEL AS

REQUIRED FOR ADDITIONAL DEVICES.

7. PROVIDE POWER AMPLIFIERS FOR ALL SPEAKERS.

8. NEW NAC PANEL SHALL MATCH THE EXISTING

NOTIFIER FIRE ALARM SYSTEM.

FS TS

TO ADDITIONAL

INDICATING

APPLIANCES

TO ADDITIONAL FLOW

AND TAMPER

SWITCHES

TO

ADDITIONAL

INITIATING

DEVICES

TO SMOKE DAMPERS

EXISTING FIRE

ALARM

CONTROL

PANEL (FACP)

SPRINKLER SYSTEM DEVICES

S S S TO ADDITIONAL FIRE

ALARM SPEAKERS

R R

CONTROL RELAY FOR

AUTO DOORS

(TYPICAL)

F

F P

EXISTING

FIRE

ALARM

PANEL

NEW

NAC

PANEL

TO ADDITIONAL

FIRE ALARM

DEVICES

F S

F S

R

R

28393

S

ARERPO

H

A M

L P

R E E

EP

I C H

S T

N

NLAOSI N E

GI

F O

ES

C O

LO

RA

DO REGI STERED

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500 Charlotte, NC 28210 704-887-3500

3/

/2

3:

:5

P

M

FA001

FIRE ALARM GENERAL NOTES AND

SYMBOLS

1 3RSB NJ

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD,

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: N.T.S.

FIRE ALARM RISER

DocuSign Envelope ID: 837E04C2-09DB-4231-8E73-CFBBA1969CC5

3/14/2019

F

F

F

F

F

F

F S

S

FA

S

FA

F S

F P

F S

F S

F S

F P

21 20.5 20 18.9 18 17 16 15.8 15

E

E.5

E.8

F.5

F.7

G

G.3

H

I

J

LIMITS OF WORK

R

R

28393

S

ARERPO

H

A M

L P

R E E

EP

I C H

S T

N

NLAOSI N E

GI

F O

ES

C O

LO

RA

DO REGI STERED

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500 Charlotte, NC 28210 704-887-3500

3/

/2

3:

:2

P

M

FA101

FIRST FLOOR FIRE ALARM DEMOLITION

PLAN

2 3RSB NJ

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD,

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: 1/8" = 1'-0"

FIRST FLOOR FIRE ALARM DEMOLITION PLAN

A. ALL EXISTING CONDITION DRAWINGS ARE

BASED ON BEST AVAILABLE INFORMATION

AT THE TIME OF SURVEY AND VISUAL

INSPECTION. VERIFY EXISTING CONDITIONS.

B. REMOVE ALL DEVICES.

C. REMOVE ALL CONDUIT NOT USED.

D. REMOVE ALL CABLING BACK TO SOURCE.

E. COORDINATE PHASING WITH COR.

0 4 8 16 NO

RTH

TRUE

1 EXISTING FIRE ALARM EQUIPMENT TO REMAIN.

2 EXISTING FIRE ALARM DEVICES TO REMAIN

15 CD

F

15 CD

F

15 CD

F

CD

F

CD

F

CD

F

15 CD

F

15 CD

F

15 CD

F

15 CD

F

15 CD

F

CD

F

15 CD

F

15 CD

F

15 CD

F

CD

F15

CD

F15

CD

F S

75 CD

1/2W

F S

CD

1/2 W

F S75

CD1/2

W

F

F S

15 CD

1/2W

F S75

CD1/2

W

F S

15 CD

1/2W

F S

C D

1/ 2W

F S

F P

F S

F S

F S

F P

21 20.5 20 18.9 18 17 16 15.8 15

E

E.5

E.8

F.5

F.7

G

G.3

H

I

J

SOILED

1A-804

PSYCH EXAM 23

1A-796

ANTE ROOM

1A-795

ISOL (NEG) EXAM 22

1A-794

WHEELCHAIR SHOWER

1A-808

EQUIPMENT STORAGE

1A-773

TLT

1A-768A

EXAM 3

1A-768

EXAM 4

1A-767

EXAM 5

1A-766

PAT. TLT

1A-786

TOILET ROOM

1A-793

TOILET ROOM

1A-792

ISOL (POS) EXAM 21

1A-791

ANTE

1A-790A

LINEN/OXYGEN

1A-772A

WORK RM

1A-772

TRIAGE

1A-761

TRIAGE

1A-762

TRIAGE

1A-763

TRIAGE

1A-759

TRIAGE

1A-758

TRANSFER COORDINATORS

1A-802

BED CONTROL

1A-802A

VISC ESCORT

1A-800

CLERK WORKROOM

1A-704

VIC

1A-705

OFFICE

1A-706

MEAN'S TEST.

1A-707

MEAN'S TEST.

1A-708

SOC. WORKER

1A-742

OFFICE

1A-743

TLT

1A-745

MED. DIR

1A-751

ADMIN. ASST.

1A-750

NURSE

1A-749

CODER OFFICE

1A-748 CONF ROOM

1A-746

BED CONTROL

1A-711

BED CONTROL

1A-710

OFFICE

1A-200E

WALK-IN VESTIBULE

C1A-754

POLICE

1A-756

AMBULANCE VESTIBULE

C1A-811

ASSISTED CARE

1A-812

MEDS

1A-814

CORRIDOR

C1A-810

RECEPTION

1A-757

CORRIDOR

C1A-764

CORRIDOR

C1A-764A

TRIAGE WORK

1A-760

CARE STATION

1A-799

REGISTRATION CLERK

1A-709

CORRIDOR

1A-741A

CORRIDOR

1A-741B

Room 1A-741C

COPY

1A-747

STOR. RM

1A-744

CORRIDOR

C1A-774

STRETCHER

C1A-809

ER/URGENT CARE WAITING

C1A-703

INTERVIEW

1A-765

CLEAN

1A-734

EXAM 11

1A-733

EXAM 12

1A-732

TOILET

1A-764B

BARIATRIC TOILET

1A-764C

SOILED

1A-739

EXAM 7

1A-738

EXAM 8

1A-737

EXAM 9

1A-736

EXAM 10

1A-735

EXAM 6

1A-728

EXAM 5

1A-727

EXAM 4

1A-726

EQUIPMENT

1A-740

EXAM 3

1A-722

EXAM 2

1A-723

EXAM 1

1A-724

CARE STATION

1A-729

MEDICATION ROOM

1A-731

ALC

1A-721

NOURISHMENT

1A-740A

EXAM 24

C1A-795

RESUS 25

1A-805

STAFF TOILET

1A-764A

EQUIPMENT

1A-725

RESUS 26

1A-807

STAFF WORK

1A-730

ALCOVE

1A-734A

CORRIDOR

C1A-711

CORRIDOR

C1A-712

CORRIDOR

C1A-713

CORRIDOR

C1A-714

CORRIDOR

C1A-715

CARE STATION

1A-799

Care Station 1A-798

CORRIDOR

C1A-718

CORRIDOR

C1A-719

CORRIDOR

C1A-720

CORRIDOR

C1A-721

Care Station 1A-797

EXAM 10

1A-801

EXAM 9

1A-803

EXAM 8

1A-806

EXAM 7

1A-777

EXAM 18

1A-790

EXAM 17

1A-809

EXAM 16

1A-810

EXAM 15

1A-811

ADMISSIONS CLERK

1A-775

EXAM 11

1A-813

EXAM 12

1A-815

EXAM 13

1A-816

EXAM 14

1A-785

BARIATRIC TOILET

1A-753

TOILET

1A-755

TOILET

1A-754

2 3

LIMITS OF WORK

R

R

28393

S

ARERPO

H

A M

L P

R E E

EP

I C H

S T

N

NLAOSI N E

GI

F O

ES

C O

LO

RA

DO REGI STERED

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500 Charlotte, NC 28210 704-887-3500

3/

/2

3:

:4

P

M

FA102

FIRST FLOOR FIRE ALARM PLAN

3 3RSB NJ

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD,

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

Scale: 1/8" = 1'-0"

FIRST FLOOR FIRE ALARM PLAN 0 4 8 16 NO

RTH

TRUE

1 EXISTING IT EQUIPMENT SEE DRAWING

TK401 FOR MORE INFORMATION.

2 EXISTING NOTIFIER FIRE ALARM PANELS TO

REMAIN.

3 PROVIDE FIRE ALARM NAC PANEL FOR THE

NEW DEVICES & CONNECT AS SHOWN.

A. PROVIDE NEW FIRE ALARM DEVICES

CABLING, COVER PLATES WITH

SELECTED MATERIAL AS SHOWN.

B. REUSE EXISTING OPENING IN THE FLOOR

OF THE INTERSTITIAL SPACE TO PROVIDE

NEW CONDUIT TO THE EXISTING WIRE WAY.

2090313 FA001
Sheets
FA001 - FIRE ALARM GENERAL NOTES AND SYMBOLS
FA101 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN
FA102 - FIRST FLOOR FIRE ALARM PLAN
2090313 FA101
Sheets
FA001 - FIRE ALARM GENERAL NOTES AND SYMBOLS
FA101 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN
FA102 - FIRST FLOOR FIRE ALARM PLAN
2090313 FA102
Sheets
FA001 - FIRE ALARM GENERAL NOTES AND SYMBOLS
FA101 - FIRST FLOOR FIRE ALARM DEMOLITION PLAN
FA102 - FIRST FLOOR FIRE ALARM PLAN
2019-03-14T08:49:35-0700
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it.