36C25619R0072-008.pdf
PDF 2 MB Posted
- Attached to
- NRM 580-17-101 Expand - Renovate ER
- Solicitation number
- 36C25619R0072
About this file
36C25619R0072 580-17-101 Project Drawings - Fire Protection.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25619C0088-000.docx | DOCX document | |
| 36C25619R0072-0003002.pdf | ||
| 36C25619R0072-0003000.docx | DOCX document | |
| 36C25619R0072-0003001.pdf | ||
| 36C25619R0072-0002000.docx | DOCX document | |
| 36C25619R0072-0002001.docx | DOCX document | |
| 36C25619R0072-0001003.pdf | ||
| 36C25619R0072-0001002.pdf | ||
| 36C25619R0072-0001004.pdf | ||
| 36C25619R0072-0001001.pdf | ||
| 36C25619R0072-0001000.docx | DOCX document | |
| 36C25619R0072-003.pdf | ||
| 36C25619R0072-004.pdf | ||
| 36C25619R0072-009.pdf | ||
| 36C25619R0072-013.pdf | ||
| 36C25619R0072-011.pdf | ||
| 36C25619R0072-006.pdf | ||
| 36C25619R0072-005.pdf | ||
| 36C25619R0072-001.docx | DOCX document | |
| 36C25619R0072-010.pdf | ||
| 36C25619R0072-002.docx | DOCX document | |
| 36C25619R0072-012.docx | DOCX document | |
| 36C25619R0072-007.pdf | ||
| 36C25619R0072-000.docx | DOCX document |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE PROTECTION LEGEND
PIPING TO BE DEMOLISHED
PIPE TURNS UP
PIPE TURNS DOWN
CONTINUATION
TIE POINT INTO EXISTING
SHUT-OFF VALVE (BALL VALVE)
SPRINKLER PIPING FP
CAPPED PIPE
QUICK RELEASE, CONCEALED
PENDANT SPRINKLER
INDICATING VALVE WITH TAMPER
SWITCH
FLOW SWITCH
LIGHT HAZARD - 0.10 GPM/1500 SQ. FT.
ORDINARY HAZARD GROUP 1 - 0.15 GPM/1500 SQ. FT.
ORDINARY HAZARD GROUP 2 - 0.20 GPM/1500 SQ. FT.
QUICK RELEASE, CONCEALED
HORIZONTAL SIDEWALL
SPRINKLER
QUICK RELEASE, UPRIGHT
SPRINKLER
BACK FLOW PREVENTER
SHUT-OFF VALVE (GATE VALVE)
FS
SIGHT GLASS
FIRE PROTECTION WATER SUPPLY
DEMAND ESTMATE
DESIGN DATA:
SYSTEM TYPE: WET
OCCUPATION CLASSIFICATION: ORD. GR. 1
DENSITY: 0.15 GPM/FT2
AREA OF APPLICATION: 1500
MINIMUM SPRINKLER DEMAND: 225 GPM
HOSE STREAMS: 100 GPM
SAFETY FACTOR: 10%
TOTAL WATER REQUIRED
(INCLUDING HOSE STREAMS): 357.5 GPM
127914
R E E
N
I
IO
O F
P R
SS
E
L
N
L EA
SE NC
I N
DE
G
SILAS P. GEORGE
S
E T A
T ETFO
S
XA
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:4
P
M
FP001
FIRE PROTECTION LEGEND,
ABBREVIATIONS, AND GENERAL
NOTES
1 3SPG SMH
RENOVATE/EXPAND
EMERGENCY ROOM SYSTEM
2002 HOLCOMBE BOULEVARD.
HOUSTON, TX 77030 4298
MARCH 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
FIRE PROTECTION GENERAL NOTES
1 THESE FIRE PROTECTION DRAWINGS ARE DIAGRAMMATIC IN NATURE. SPRINKLER HEAD TYPES AND APPROXIMATE LOCATIONS HAVE BEEN
ESTABLISHED. THE FIRE PROTECTION LAYOUT INDICATED IS FOR REFERENCE ONLY. FINAL SYSTEM LAYOUT AND PIPE ROUTING SHALL BE DETERMINED BY THE FIRE PROTECTION CONTRACTOR AND SHALL TAKE INTO CONSIDERATION THE BUILDING STRUCTURE, ARCHITECTURAL
FEATURES AND SHALL BE COORDINATED WITH THE WORK OF OTHER TRADES. THE FIRE PROTECTION CONTRACTORS SHALL PROVIDE WORKING
DRAWINGS IN ACCORDANCE WITH NFPA 13 FOR REVIEW AND APPROVAL BY COR.
2 ADJUST SPRINKLERS TO BE PLACED IN THE CENTER OF THE CEILING TILE IT IS SHOWN IN.
3 MODIFICATION TO EXISTING SPRINKLER SYSTEMS SHALL RESULT IN A COMPLETE AND WORKING WET PIPE SPRINKLER SYSTEM THAT IS IN
COMPLIANCE WITH CONTRACT DOCUMENTS AND NFPA 13.
4 ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH NFPA 13, THE DEPARTMENT OF VETERANS AFFAIRS, FIRE PROTECTION DESIGN
MANUAL 7TH EDITION AND ALL OTHER APPLICABLE CODES AND STANDARDS.
5 LIGHT HAZARD OCCUPANCIES: OFFICE AND CUSTOMARY ACCESS AREAS. LIGHT HAZARD SPACES SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE A MINIMUM DENSITY OF 0.10 GPM/SQ.FT. OVER THE HYDRAULICALLY MOST REMOTE 1500 SQ.FT.
6 ORDINARY HAZARD GROUP 1 OCCUPANCIES: MECHANICAL ROOMS, TRANSFORMER ROOMS, ELECTRICAL SWITCHGEAR ROOMS AND ELECTRICAL CLOSETS. ORDINARY HAZARD GROUP 1 SPACES SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE A MINIMUM DENSITY OF 0.15
GPM/SQ.FT. OVER THE HYDRAULICALLY MOST REMOTE 1500 SQ.FT.
7 ORDINARY HAZARD GROUP 2 OCCUPANCIES: STORAGE ROOMS, TRASH ROOMS, CLEAN AND SOILED LINEN ROOMS AND KITCHENS. ORDINARY HAZARD GROUP 2 SPACES SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE A MINIMUM DENSITY OF 0.20 GPM/SQ.FT. OVER THE
HYDRAULICALLY MOST REMOTE 1500 SQ.FT.
8 PRIOR TO THE OPERATION (OPENING OR CLOSING) OF ANY VALVES CONTROLLING WATER TO THE DOMESTIC OR FIRE SYSTEMS, NOTIFICATION SHALL BE GIVEN TO THE COR AND APPROVAL MUST BE OBTAINED BEFORE BEGINNING OF WORK.
9 PROVIDE PIPING OFFSETS AS REQUIRED TO AVOID DUCTWORK, STRUCTURE, OTHER TRADES OR OTHER OBSTRUCTIONS.
10 ALL PIPE SHALL BE INSTALLED ABOVE CEILINGS IN AREAS WITH FINISHED CEILINGS AND CORRESPONDING SPRINKLER HEADS SHALL BE RECESSED. IN AREAS WITH EXPOSED STRUCTURE, PIPING SHALL BE EXPOSED AND PAINTED TO MATCH ADJACENT SURFACES. IN NO CASE SHALL ANY EXPOSED EXPOSED SPRINKLER PIPING BE INSTALLED BELOW THE BOTTOM HORIZONTAL PLANE OF LIGHTING FIXTURES.
11 NEW ZONE PIPING SHALL BE HYDRAULICALLY CALCULATED WITH THE AVAILABLE SUPPLY AND RESIDUAL PRESSURE AS SHOWN IN THE SPECIFICATIONS. PERFORM HYDRAULIC CALCULATIONS UTILIZING THE AREA/DENSITY METHOD. DESIGN AREA REDUCTIONS ARE PERMITTED WHEN USING QUICK RESPONSE SPRINKLERS. MINIMUM DESIGN AREA IS 1500 SQ.FT. INCLUDE AN ALLOWANCE FOR A 250 GPM HOSE STREAM AT THE BASE OF THE RISER. SHOP DRAWINGS SHALL BE PREPARED AND SEALED STAMPED BY A REGISTERED PROFESSIONAL ENGINEER IN THE
FIELD OF FIRE PROTECTION.
12 VERIFY ALL DISTANCES, HEIGHTS AND DIMENSIONS OF THE BUILDING AND ITS SYSTEMS PRIOR TO THE START OF WORK.
13 INSTALL QUICK RESPONSE SPRINKLERS (QRS) IN ALL AREAS EXCEPT WHERE SPECIFICALLY PROHIBITED (E.G., HIGH TEMPERATURE AREAS AS
DEFINED IN NFPA 13). ALL SPRINKLERS SHALL BE UL LISTED AND FM APPROVED.
14 ALL VALVES SHALL BE READILY ACCESSIBLE FOR OPERATION.
15 CONTRACTOR SHALL PROVIDE LOW POINT DRAINS AS REQUIRED BY NFPA 13. ALL LOW POINTS SHALL BE MARKED WITH A SIGN INDICATING
"AUXILIARY DRAIN".
16 TEST SPRINKLER SYSTEM, CONTROLS, PIPING AND MONITORING IN ACCORDANCE WITH NFPA 25.
17 NO STRUCTURAL MEMBERS SHALL BE CUT, DRILLED, OR BURNED.
DocuSign Envelope ID: 7F0BDB62-5146-4079-B1A0-D12C70ECAC76
3/14/2019
A A
A
A A
A
20.5 20 1515.816171818.9
E
G
H
I
J
G.3
F.7
F.5
E.8
E.5
F S
3" FS
F S
3" FS
127914
R E E
N
I
IO
O F
P R
SS
E
L
N
L EA
SE NC
I N
DE
G
SILAS P. GEORGE
S
E T A
T ETFO
S
XA
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:3
P
M
FD101
FIRST FLOOR FIRE PROTECTION
DEMOLITION PLAN
2 3SPG SMH
RENOVATE/EXPAND
EMERGENCY ROOM SYSTEM
2002 HOLCOMBE BOULEVARD.
HOUSTON, TX 77030 4298
MARCH 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
SCALE: 1/8" = 1'-0"1
LEVEL A FIRE PROTECTION DEMOLITION PLAN 0 4 8 16 N
O R
TH
TRUE
A COORDINATE WORKING HOURS ALLOWED WITH
THE VA COR.
B ALL ITEMS NOT CALLED OUT FOR DEMOLTION
ARE TO REMAIN UNDISTURBED.
C ALL COMBUSTIBLE MATERIAL SHALL BE
REMOVED FROM THE AREA OF WORK DURING
DEMOLITION BEFORE SPRINKLERS ARE TAKEN
OUT OF SERVICE.
1 REMOVE EXISTING SPRINKLER HEADS
IN AREA OF WORK. CONNECTING
BRANCH PIPING SERVING HEADS ARE
TO REMAIN.
J
J
J
J
J
J
J
J
J
J
J
J
J
J
20.5 20 1515.816171818.9
E
G
H
I
J
G.3
F.7
F.5
E.8
E.5
3" FS
F S
3" FS
F S
SOILED
1A-804
PSYCH EXAM 23
1A-796
ANTE ROOM
1A-795
ISOL (NEG) EXAM
1A-794
WHEELCHAIR
SHOWER
1A-808
EQUIPMENT
STORAGE
1A-773
TLT
1A-768A
EXAM 3
1A-768
EXAM 4
1A-767
EXAM 5
1A-766
PAT. TLT
1A-786
TOILET ROOM
1A-793
TOILET ROOM
1A-792
ISOL (POS) EXAM
1A-791
ANTE
1A-790A
WORK RM
1A-772
TRIAGE
1A-761
TRIAGE
1A-762
TRIAGE
1A-763
TRIAGE
1A-759
TRIAGE
1A-758
TRANSFER
COORDINATORS
1A-802
BED CONTROL
1A-802A
VISC ESCORT
1A-800
CLERK
WORKROOM
1A-704
VIC
1A-705
OFFICE
1A-706
MEAN'S TEST.
1A-707
MEAN'S TEST.
1A-708
SOC. WORKER
1A-742
OFFICE
1A-743
TLT
1A-745
MED. DIR
1A-751
ADMIN. ASST.
1A-750
NURSE
1A-749
CODER OFFICE
1A-748 CONF ROOM
1A-746
BED CONTROL
1A-711
BED CONTROL
1A-710
OFFICE
1A-200E
WALK-IN
VESTIBULE
C1A-754
POLICE
1A-756
AMBULANCE
VESTIBULE
C1A-811
ASSISTED CARE
1A-812
MEDS
1A-814
CORRIDOR
C1A-810
RECEPTION
1A-757
CORRIDOR
C1A-764
CORRIDOR
C1A-764A
TRIAGE WORK
1A-760
CARE STATION
1A-799
REGISTRATION
CLERK
1A-709
CORRIDOR
1A-741A
CORRIDOR
1A-741B
Room
1A-741C
COPY
1A-747
STOR. RM
1A-744
CORRIDOR
C1A-774
STRETCHER
C1A-809
ER/URGENT CARE
WAITING
C1A-703
INTERVIEW
1A-765
CLEAN
1A-734
EXAM 11
1A-733
EXAM 12
1A-732
TOILET
1A-764B
BARIATRIC TOILET
1A-764C
SOILED
1A-739
EXAM 7
1A-738
EXAM 8
1A-737
EXAM 9
1A-736
EXAM 10
1A-735
EXAM 6
1A-728
EXAM 5
1A-727
EXAM 4
1A-726
EQUIPMENT
1A-740
EXAM 3
1A-722
EXAM 2
1A-723
EXAM 1
1A-724
CARE STATION
1A-729
MEDICATION
ROOM
1A-731
ALC
1A-721
NOURISHMENT
1A-740A
EXAM 24
C1A-795
RESUS 25
1A-805
STAFF TOILET
1A-764A
EQUIPMENT
1A-725
RESUS 26
1A-807
STAFF WORK
1A-730
ALCOVE
1A-734A
CORRIDOR
C1A-711
CORRIDOR
C1A-712
CORRIDOR
C1A-713
CORRIDOR
C1A-714
CORRIDOR
C1A-715
BARIATRIC TOILET
1A-753
TOILET
1A-754
TOILET
1A-755
127914
R E E
N
I
IO
O F
P R
SS
E
L
N
L EA
SE NC
I N
DE
G
SILAS P. GEORGE
S
E T A
T ETFO
S
XA
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved: Mark Landwert - COR
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500
Charlotte, NC 28210
704-887-3500
/1
/2
:1
:5
P
M
FP101
FIRST FLOOR FIRE PROTECTION PLAN
3 3SPG SMH
RENOVATE/EXPAND
EMERGENCY ROOM SYSTEM
2002 HOLCOMBE BOULEVARD.
HOUSTON, TX 77030 4298
MARCH 15, 2019
100% CONSTRUCTION DOCUMENTS
580-17-10116-352
A COORDINATE WORKING HOURS ALLOWED
WITH THE VA COR.
B CONTRACTOR SHALL FIRE STOP ALL
PENETRATIONS.
C UNLESS NOTED OTHERWISE, ALL ROOM'S
SPRINKLER SYSTEM SHALL BE DESIGNED AS
"LIGHT HAZARD".
D EXISTING SPRINKLER HEADS SHALL NOT BE
REUSED.
E FIRE PROTECTION EVALUATED ONLY FOR THE
AREA WITHIN THE LIMIT OF WORK.
SCALE: 1/8" = 1'-0"1
LEVEL A FIRE PROTECTION PLAN 0 4 8 16 N
O R
TH
TRUE
1 ROOM TO BE DESIGNATED AS "ORDINARY
HAZARD GROUP 1".
2 ROOM TO BE DESIGNATED AS "ORDINARY
HAZARD GROUP 2".
| Sheets |
| FP001 - FIRE PROTECTION LEGEND, ABBREVIATIONS, AND GENERAL NOTES |
| FD101 - FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN |
| FP101 - FIRST FLOOR FIRE PROTECTION PLAN |
| 2019-03-14T11:46:06-0700 | |
| Digitally verifiable PDF exported from www.docusign.com |
File details come from the government source that posted it.