36C25619R0072-008.pdf

PDF 2 MB Posted

Attached to
NRM 580-17-101 Expand - Renovate ER
Solicitation number
36C25619R0072
Issued by

About this file

36C25619R0072 580-17-101 Project Drawings - Fire Protection.pdf

View the file

Other files

File Type Posted
36C25619C0088-000.docx DOCX document
36C25619R0072-0003002.pdf PDF
36C25619R0072-0003000.docx DOCX document
36C25619R0072-0003001.pdf PDF
36C25619R0072-0002000.docx DOCX document
36C25619R0072-0002001.docx DOCX document
36C25619R0072-0001003.pdf PDF
36C25619R0072-0001002.pdf PDF
36C25619R0072-0001004.pdf PDF
36C25619R0072-0001001.pdf PDF
36C25619R0072-0001000.docx DOCX document
36C25619R0072-003.pdf PDF
36C25619R0072-004.pdf PDF
36C25619R0072-009.pdf PDF
36C25619R0072-013.pdf PDF
36C25619R0072-011.pdf PDF
36C25619R0072-006.pdf PDF
36C25619R0072-005.pdf PDF
36C25619R0072-001.docx DOCX document
36C25619R0072-010.pdf PDF
36C25619R0072-002.docx DOCX document
36C25619R0072-012.docx DOCX document
36C25619R0072-007.pdf PDF
36C25619R0072-000.docx DOCX document
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE PROTECTION LEGEND

PIPING TO BE DEMOLISHED

PIPE TURNS UP

PIPE TURNS DOWN

CONTINUATION

TIE POINT INTO EXISTING

SHUT-OFF VALVE (BALL VALVE)

SPRINKLER PIPING FP

CAPPED PIPE

QUICK RELEASE, CONCEALED

PENDANT SPRINKLER

INDICATING VALVE WITH TAMPER

SWITCH

FLOW SWITCH

LIGHT HAZARD - 0.10 GPM/1500 SQ. FT.

ORDINARY HAZARD GROUP 1 - 0.15 GPM/1500 SQ. FT.

ORDINARY HAZARD GROUP 2 - 0.20 GPM/1500 SQ. FT.

QUICK RELEASE, CONCEALED

HORIZONTAL SIDEWALL

SPRINKLER

QUICK RELEASE, UPRIGHT

SPRINKLER

BACK FLOW PREVENTER

SHUT-OFF VALVE (GATE VALVE)

FS

SIGHT GLASS

FIRE PROTECTION WATER SUPPLY

DEMAND ESTMATE

DESIGN DATA:

SYSTEM TYPE: WET

OCCUPATION CLASSIFICATION: ORD. GR. 1

DENSITY: 0.15 GPM/FT2

AREA OF APPLICATION: 1500

MINIMUM SPRINKLER DEMAND: 225 GPM

HOSE STREAMS: 100 GPM

SAFETY FACTOR: 10%

TOTAL WATER REQUIRED

(INCLUDING HOSE STREAMS): 357.5 GPM

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:4

P

M

FP001

FIRE PROTECTION LEGEND,

ABBREVIATIONS, AND GENERAL

NOTES

1 3SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

FIRE PROTECTION GENERAL NOTES

1 THESE FIRE PROTECTION DRAWINGS ARE DIAGRAMMATIC IN NATURE. SPRINKLER HEAD TYPES AND APPROXIMATE LOCATIONS HAVE BEEN

ESTABLISHED. THE FIRE PROTECTION LAYOUT INDICATED IS FOR REFERENCE ONLY. FINAL SYSTEM LAYOUT AND PIPE ROUTING SHALL BE DETERMINED BY THE FIRE PROTECTION CONTRACTOR AND SHALL TAKE INTO CONSIDERATION THE BUILDING STRUCTURE, ARCHITECTURAL

FEATURES AND SHALL BE COORDINATED WITH THE WORK OF OTHER TRADES. THE FIRE PROTECTION CONTRACTORS SHALL PROVIDE WORKING

DRAWINGS IN ACCORDANCE WITH NFPA 13 FOR REVIEW AND APPROVAL BY COR.

2 ADJUST SPRINKLERS TO BE PLACED IN THE CENTER OF THE CEILING TILE IT IS SHOWN IN.

3 MODIFICATION TO EXISTING SPRINKLER SYSTEMS SHALL RESULT IN A COMPLETE AND WORKING WET PIPE SPRINKLER SYSTEM THAT IS IN

COMPLIANCE WITH CONTRACT DOCUMENTS AND NFPA 13.

4 ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH NFPA 13, THE DEPARTMENT OF VETERANS AFFAIRS, FIRE PROTECTION DESIGN

MANUAL 7TH EDITION AND ALL OTHER APPLICABLE CODES AND STANDARDS.

5 LIGHT HAZARD OCCUPANCIES: OFFICE AND CUSTOMARY ACCESS AREAS. LIGHT HAZARD SPACES SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE A MINIMUM DENSITY OF 0.10 GPM/SQ.FT. OVER THE HYDRAULICALLY MOST REMOTE 1500 SQ.FT.

6 ORDINARY HAZARD GROUP 1 OCCUPANCIES: MECHANICAL ROOMS, TRANSFORMER ROOMS, ELECTRICAL SWITCHGEAR ROOMS AND ELECTRICAL CLOSETS. ORDINARY HAZARD GROUP 1 SPACES SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE A MINIMUM DENSITY OF 0.15

GPM/SQ.FT. OVER THE HYDRAULICALLY MOST REMOTE 1500 SQ.FT.

7 ORDINARY HAZARD GROUP 2 OCCUPANCIES: STORAGE ROOMS, TRASH ROOMS, CLEAN AND SOILED LINEN ROOMS AND KITCHENS. ORDINARY HAZARD GROUP 2 SPACES SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE A MINIMUM DENSITY OF 0.20 GPM/SQ.FT. OVER THE

HYDRAULICALLY MOST REMOTE 1500 SQ.FT.

8 PRIOR TO THE OPERATION (OPENING OR CLOSING) OF ANY VALVES CONTROLLING WATER TO THE DOMESTIC OR FIRE SYSTEMS, NOTIFICATION SHALL BE GIVEN TO THE COR AND APPROVAL MUST BE OBTAINED BEFORE BEGINNING OF WORK.

9 PROVIDE PIPING OFFSETS AS REQUIRED TO AVOID DUCTWORK, STRUCTURE, OTHER TRADES OR OTHER OBSTRUCTIONS.

10 ALL PIPE SHALL BE INSTALLED ABOVE CEILINGS IN AREAS WITH FINISHED CEILINGS AND CORRESPONDING SPRINKLER HEADS SHALL BE RECESSED. IN AREAS WITH EXPOSED STRUCTURE, PIPING SHALL BE EXPOSED AND PAINTED TO MATCH ADJACENT SURFACES. IN NO CASE SHALL ANY EXPOSED EXPOSED SPRINKLER PIPING BE INSTALLED BELOW THE BOTTOM HORIZONTAL PLANE OF LIGHTING FIXTURES.

11 NEW ZONE PIPING SHALL BE HYDRAULICALLY CALCULATED WITH THE AVAILABLE SUPPLY AND RESIDUAL PRESSURE AS SHOWN IN THE SPECIFICATIONS. PERFORM HYDRAULIC CALCULATIONS UTILIZING THE AREA/DENSITY METHOD. DESIGN AREA REDUCTIONS ARE PERMITTED WHEN USING QUICK RESPONSE SPRINKLERS. MINIMUM DESIGN AREA IS 1500 SQ.FT. INCLUDE AN ALLOWANCE FOR A 250 GPM HOSE STREAM AT THE BASE OF THE RISER. SHOP DRAWINGS SHALL BE PREPARED AND SEALED STAMPED BY A REGISTERED PROFESSIONAL ENGINEER IN THE

FIELD OF FIRE PROTECTION.

12 VERIFY ALL DISTANCES, HEIGHTS AND DIMENSIONS OF THE BUILDING AND ITS SYSTEMS PRIOR TO THE START OF WORK.

13 INSTALL QUICK RESPONSE SPRINKLERS (QRS) IN ALL AREAS EXCEPT WHERE SPECIFICALLY PROHIBITED (E.G., HIGH TEMPERATURE AREAS AS

DEFINED IN NFPA 13). ALL SPRINKLERS SHALL BE UL LISTED AND FM APPROVED.

14 ALL VALVES SHALL BE READILY ACCESSIBLE FOR OPERATION.

15 CONTRACTOR SHALL PROVIDE LOW POINT DRAINS AS REQUIRED BY NFPA 13. ALL LOW POINTS SHALL BE MARKED WITH A SIGN INDICATING

"AUXILIARY DRAIN".

16 TEST SPRINKLER SYSTEM, CONTROLS, PIPING AND MONITORING IN ACCORDANCE WITH NFPA 25.

17 NO STRUCTURAL MEMBERS SHALL BE CUT, DRILLED, OR BURNED.

DocuSign Envelope ID: 7F0BDB62-5146-4079-B1A0-D12C70ECAC76

3/14/2019

A A

A

A A

A

20.5 20 1515.816171818.9

E

G

H

I

J

G.3

F.7

F.5

E.8

E.5

F S

3" FS

F S

3" FS

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:3

P

M

FD101

FIRST FLOOR FIRE PROTECTION

DEMOLITION PLAN

2 3SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

SCALE: 1/8" = 1'-0"1

LEVEL A FIRE PROTECTION DEMOLITION PLAN 0 4 8 16 N

O R

TH

TRUE

A COORDINATE WORKING HOURS ALLOWED WITH

THE VA COR.

B ALL ITEMS NOT CALLED OUT FOR DEMOLTION

ARE TO REMAIN UNDISTURBED.

C ALL COMBUSTIBLE MATERIAL SHALL BE

REMOVED FROM THE AREA OF WORK DURING

DEMOLITION BEFORE SPRINKLERS ARE TAKEN

OUT OF SERVICE.

1 REMOVE EXISTING SPRINKLER HEADS

IN AREA OF WORK. CONNECTING

BRANCH PIPING SERVING HEADS ARE

TO REMAIN.

J

J

J

J

J

J

J

J

J

J

J

J

J

J

20.5 20 1515.816171818.9

E

G

H

I

J

G.3

F.7

F.5

E.8

E.5

3" FS

F S

3" FS

F S

SOILED

1A-804

PSYCH EXAM 23

1A-796

ANTE ROOM

1A-795

ISOL (NEG) EXAM

1A-794

WHEELCHAIR

SHOWER

1A-808

EQUIPMENT

STORAGE

1A-773

TLT

1A-768A

EXAM 3

1A-768

EXAM 4

1A-767

EXAM 5

1A-766

PAT. TLT

1A-786

TOILET ROOM

1A-793

TOILET ROOM

1A-792

ISOL (POS) EXAM

1A-791

ANTE

1A-790A

WORK RM

1A-772

TRIAGE

1A-761

TRIAGE

1A-762

TRIAGE

1A-763

TRIAGE

1A-759

TRIAGE

1A-758

TRANSFER

COORDINATORS

1A-802

BED CONTROL

1A-802A

VISC ESCORT

1A-800

CLERK

WORKROOM

1A-704

VIC

1A-705

OFFICE

1A-706

MEAN'S TEST.

1A-707

MEAN'S TEST.

1A-708

SOC. WORKER

1A-742

OFFICE

1A-743

TLT

1A-745

MED. DIR

1A-751

ADMIN. ASST.

1A-750

NURSE

1A-749

CODER OFFICE

1A-748 CONF ROOM

1A-746

BED CONTROL

1A-711

BED CONTROL

1A-710

OFFICE

1A-200E

WALK-IN

VESTIBULE

C1A-754

POLICE

1A-756

AMBULANCE

VESTIBULE

C1A-811

ASSISTED CARE

1A-812

MEDS

1A-814

CORRIDOR

C1A-810

RECEPTION

1A-757

CORRIDOR

C1A-764

CORRIDOR

C1A-764A

TRIAGE WORK

1A-760

CARE STATION

1A-799

REGISTRATION

CLERK

1A-709

CORRIDOR

1A-741A

CORRIDOR

1A-741B

Room

1A-741C

COPY

1A-747

STOR. RM

1A-744

CORRIDOR

C1A-774

STRETCHER

C1A-809

ER/URGENT CARE

WAITING

C1A-703

INTERVIEW

1A-765

CLEAN

1A-734

EXAM 11

1A-733

EXAM 12

1A-732

TOILET

1A-764B

BARIATRIC TOILET

1A-764C

SOILED

1A-739

EXAM 7

1A-738

EXAM 8

1A-737

EXAM 9

1A-736

EXAM 10

1A-735

EXAM 6

1A-728

EXAM 5

1A-727

EXAM 4

1A-726

EQUIPMENT

1A-740

EXAM 3

1A-722

EXAM 2

1A-723

EXAM 1

1A-724

CARE STATION

1A-729

MEDICATION

ROOM

1A-731

ALC

1A-721

NOURISHMENT

1A-740A

EXAM 24

C1A-795

RESUS 25

1A-805

STAFF TOILET

1A-764A

EQUIPMENT

1A-725

RESUS 26

1A-807

STAFF WORK

1A-730

ALCOVE

1A-734A

CORRIDOR

C1A-711

CORRIDOR

C1A-712

CORRIDOR

C1A-713

CORRIDOR

C1A-714

CORRIDOR

C1A-715

BARIATRIC TOILET

1A-753

TOILET

1A-754

TOILET

1A-755

127914

R E E

N

I

IO

O F

P R

SS

E

L

N

L EA

SE NC

I N

DE

G

SILAS P. GEORGE

S

E T A

T ETFO

S

XA

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved: Mark Landwert - COR

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 5960 Fairview Road, Suite 500

Charlotte, NC 28210

704-887-3500

/1

/2

:1

:5

P

M

FP101

FIRST FLOOR FIRE PROTECTION PLAN

3 3SPG SMH

RENOVATE/EXPAND

EMERGENCY ROOM SYSTEM

2002 HOLCOMBE BOULEVARD.

HOUSTON, TX 77030 4298

MARCH 15, 2019

100% CONSTRUCTION DOCUMENTS

580-17-10116-352

A COORDINATE WORKING HOURS ALLOWED

WITH THE VA COR.

B CONTRACTOR SHALL FIRE STOP ALL

PENETRATIONS.

C UNLESS NOTED OTHERWISE, ALL ROOM'S

SPRINKLER SYSTEM SHALL BE DESIGNED AS

"LIGHT HAZARD".

D EXISTING SPRINKLER HEADS SHALL NOT BE

REUSED.

E FIRE PROTECTION EVALUATED ONLY FOR THE

AREA WITHIN THE LIMIT OF WORK.

SCALE: 1/8" = 1'-0"1

LEVEL A FIRE PROTECTION PLAN 0 4 8 16 N

O R

TH

TRUE

1 ROOM TO BE DESIGNATED AS "ORDINARY

HAZARD GROUP 1".

2 ROOM TO BE DESIGNATED AS "ORDINARY

HAZARD GROUP 2".

Sheets
FP001 - FIRE PROTECTION LEGEND, ABBREVIATIONS, AND GENERAL NOTES
FD101 - FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN
FP101 - FIRST FLOOR FIRE PROTECTION PLAN
2019-03-14T11:46:06-0700
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it.