36C25619R0042-035.pdf

PDF 267 KB Posted

Attached to
Install Roll Down Gates for Garages Federal contract opportunity
Solicitation number
36C25619R0042
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

About this file

36C25619R0042 0409-4TN101-K.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Install Roll Down Gates for Garages, newest first.
File Type Posted
36C25619C0123-000.docx DOCX document
36C25619R0042-0005000.docx DOCX document
36C25619R0042-0004000.docx DOCX document
00152-LL110-Staff_Parking.pdf PDF
00157-LL115-Patient_Visitor_Parking.pdf PDF
Proposed_Bollard_Location_-_Employee_Parking_Garage_(002).pdf PDF
36C25619R0042_0003.docx DOCX document
Cast_In_Place.pdf PDF
00154-LL112-Patient_Visitor_Parking.pdf PDF
36C25619R0042-0002000.docx DOCX document
36C25619R0042-0001000.docx DOCX document
36C25619R0042-036.pdf PDF
36C25619R0042-022.pdf PDF
36C25619R0042-033.pdf PDF
36C25619R0042-029.pdf PDF
36C25619R0042-012.docx DOCX document
36C25619R0042-032.pdf PDF
36C25619R0042-028.pdf PDF
36C25619R0042-004.docx DOCX document
36C25619R0042-039.pdf PDF
36C25619R0042-006.docx DOCX document
36C25619R0042-024.pdf PDF
36C25619R0042-030.pdf PDF
36C25619R0042-008.pdf PDF
36C25619R0042-023.pdf PDF
36C25619R0042-034.pdf PDF
36C25619R0042-019.pdf PDF
36C25619R0042-011.doc DOC document
36C25619R0042-020.pdf PDF
36C25619R0042-013.pdf PDF
36C25619R0042-015.docx DOCX document
36C25619R0042-010.pdf PDF
36C25619R0042-037.pdf PDF
36C25619R0042-003.pdf PDF
36C25619R0042-025.pdf PDF
36C25619R0042-038.pdf PDF
36C25619R0042-031.pdf PDF
36C25619R0042-016.pdf PDF
36C25619R0042-014.pdf PDF
36C25619R0042-027.pdf PDF
36C25619R0042-017.pdf PDF
36C25619R0042-018.pdf PDF
36C25619R0042-021.pdf PDF
36C25619R0042-007.pdf PDF
36C25619R0042-005.xlsx XLSX spreadsheet
36C25619R0042-009.pdf PDF
36C25619R0042-002.docx DOCX document
36C25619R0042-026.pdf PDF
36C25619R0042-001.docx DOCX document
36C25619R0042-000.docx DOCX document
Show all 50

Install Roll Down Gates for Garages has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

FLEET

ENTRY/EXIT

S S

SLOUNGE

1K116

ST

1K116A

ST

1K116B

DISPATCH

CUBICLES

1K114

STP

TRANS

SUPV

1K114A

ELEC

1K108

ATTENDANT

OFFICE

1K112

WC

STOR

1K109

STAIR

STK-1

STAIR

STK-2

STP

HE

N

M

L

K

J

H

G

F

E

D

C

EQUIPMENT

STORAGE

1K105

TELECOM

1K104

SECURITY

1K106

SECURITY

1K101

TEL-DATA

1K103

MECHANICAL

1K110

G7

4AS101K

4AI410

2AI101G

4AS101K

1.4

3.6

C

PULL BOX - SEE

PULL BOX DETAIL

FOR SIZES.

(4) 4" TIE

CONDUITS

(3) 4"

SLEEVES

(4) 4" CONDUITS UP

ABOVE CEILING ON

GARAGE 6TH FLOOR:

(2) 4" CONDUITS TO MCR

(2) 4" CONDUITS TO TER

4TN501

4TN501

WL

WWL

W

WL

A A

A A

NOTE 1NOTE 1

NOTE 1NOTE 1

NOTE 2NOTE 2

NOTE 2NOTE 2

TERMINATE CABLES WEST

OF COLUMN LINE H IN TR

1K104 - SEE NOTE 1.

TERMINATE CABLES EAST

OF COLUMN LINE H IN TR

1K103 - SEE NOTE 2.

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H A L

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

E E T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

X T

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

4TN101-K

BUILDING 04 TELECOM FIRST FLOOR PARKING

JLE JJPJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

EWP_04

1/16" = 1'-0"

BUILDING 04 TELECOM LEVEL ONE

DEVICE COUNT FIRST FLOOR

OUTLET SUBSCRIPT

VOICE

PORTS

DATA

PORTS

OUTLET

COUNT

DATA

PANELS

VOICE

PANELS

Standard

10 10 5 0.21 0.21

Wall Phone

WALL PHONE W 2 0 2 0 0.04

Wireless

WL 0 6 3 0.13 0

12 16 10 0.33 0.25

NOTES:

1. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED

FOR TELECOM AND SECURITY CONDUITS WEST OF COLUMN H.

2. VERTICAL SPACE BETWEEN PRECAST PANELS ALONG STICH WALL RESERVED

FOR TELECOM AND SECURITY CONDUITS EAST OF COLUMN H.

File details come from the government source that posted it.