36C25619R0042-028.pdf
PDF 223 KB Posted
- Attached to
- Install Roll Down Gates for Garages Federal contract opportunity
- Solicitation number
- 36C25619R0042
About this file
36C25619R0042 0318-5PL101.pdf
View the file
Other files for this federal contract opportunity
Show all 50
Install Roll Down Gates for Garages has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
A
G
FC
I
UP
ATTENDANT OFFICE
1L106
STAIR
STL-2
STAIR
STL-1
8" R
L
8" R
L
8" R
L
6" R
L
8" R
L
TEL-DATA
1L107
SECURITY
1L105
SECURITY
1L108
TEL-DATA
1L110
10" RL (10,200 sq/ft)- DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE 1-ST FLOOR LEVEL
WITH 10" ZURN Z-199 DOWNSPOUT NOZZLE
6" R
L
10" RL (16,200 sq/ft)-UP-DISCHARGE TO RAIN GARDENS.
TERMINATE 14" BELOW 1-ST FLOOR LEVEL
WITH 10" ZURN Z-199 DOWNSPOUT NOZZLE
4"W-UP
4"FD-B
6"RL-UP (5,600 sq/ft)
4"WS-UP&DN
4"WS-UP&DN
8"RL-UP (9,000 sq/ft)
4"W-UP
4"WS-UP&DN
4"W-UP
4"WS-UP&DN
4"W-UP
8"RL-UP (9.000 sq/ft)
4"FD-B
4"W-UP
6"RL-UP (5,100 sq/ft)
4"W-UP
4"WS-UP&DN
4"WS-UP&DN
4"W-UP
4"FD-B
4"W-UP
4"WS-UP&DN
4"W-UP
6"RL-UP (4,600 sq/ft)
C
G
H
J
K
L
N
E
F
M
D
3.6
1"CW RISER-UP 4"WS-UP
6"RL-UP (4,600 sq/ft)
3/4"CW TO P-811
6" RL (2,800 sq/ft)-UP-DISCHARGE TO RAIN GARDENS.
TERMINATE 14" BELOW 1-ST FLOOR LEVEL
WITH 10" ZURN Z-199 DOWNSPOUT NOZZLE
4"W-UP
4"FD-B
4"WS-UP&DN
8" RL (9,000 sq/ft)- DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE 1-ST FLOOR LEVEL
WITH 10" ZURN Z-199 DOWNSPOUT NOZZLE
8" RL (9,000 sq/ft)- DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE 1-ST FLOOR LEVEL
WITH 10" ZURN Z-199 DOWNSPOUT NOZZLE
8" RL (9,700 sq/ft) -DISCHARGE TO RAIN GARDENS
TERMINATE 7" ABOVE 1-ST FLOOR LEVEL
WITH 10" ZURN Z-199 DOWNSPOUT NOZZLE
3/4"CW TO P-811
3/4"CW RISER-UP
3/4"CW TO P-811
(2)4"V-UP&DN
P-811 P-811 P-811
P-811 P-811
FCO
CO CO
3/4"PRV
3/ 4"
C W
3/4" CW3/4" CW3/4" CW
FCO
CO
CO
4"W-UP
3/4"CW TO P-811
CO
FCO
FCO
CO
CO
8" R
L
8" RL 10" RL
" R
L
FCO
3/4"PRV
CO
FCO
FCO
FCO
FCO
4"WS-UP&DN
CO
4"FD-B
4"FD-B
4"FD-B
4"FD-B
4"FD-B
4"FD-B
4"FD-B
FCO
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
5PL101
BLDG 5 FIRST FLOOR PLUMBING PLAN
PDF YVJune 30, 2011
Construction Documents 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERS / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERS, INC. / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
3/32" = 1'-0"1 BLDG 5 FIRST FLOOR PLAN
4 Addendum 4 08/05/11
RFI-04455: FD Revised location near K/4
File details come from the government source that posted it.