36C25619R0042-027.pdf
PDF 647 KB Posted
- Attached to
- Install Roll Down Gates for Garages
- Solicitation number
- 36C25619R0042
About this file
36C25619R0042 0302-4PL101.pdf
View the file
Other files
Show 40 more
Latest 50 of 53 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Tectonic Copyright 2007
Tectonic Cop yright 2007
UP
A
G
FC
I
UP
UP
DN
N
L
K
J
H
G
F
E
C
D
3.6
1.4
1.69
DISPATCH & CUBICLES
1K114
ATTENDANT OFFICE
1K112
MECHANICAL
1K110 ELEC
1K108
STAIR-1
STK-1-1
STAIR-1
STK-2-1
WC STOR
1K109
EQUIPMENT STORAGE
1K105
EQUIPMENT STORAGE
1K107
TELECOM
1K104
LOUNGE
1K116
SECURITY
1K106
10" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(14911 sq/ft)
4PL400
10" RL
6" R
L
" R
L
6" R
L
" R
L
6" R
L
6" RL
6" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(4464 sq/ft)
6" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(4464 sq/ft)
6" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
( 2232 sq/ft)
6" RL (4185 sq/ft)
DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
6" RL
6" R
L
8" RL (9035 sq/ft) & 6" OFD (1350 sq/ft)
DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(4685 sq/ft)
6" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(2232 sq/ft)
6" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(4464 sq/ft)
6" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(4464 sq/ft)
10" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(10726 sq/ft)
6" RL DISCHARGE TO RAIN GARDENS.
TERMINATE 7" ABOVE GRADE
WITH 10" ZURN Z-199
DOWNSPOUT NOZZLE
(4185 sq/ft)
6" R
L
6" R
L
6" R
L
6" RL
FCO
FCO
FCO
FCO
2"V-UP
2"V-DN
COCO
COCOCO
CO
CO
CO
CO CO
6"RL-UP
(500 sq/ft)
6" RL-UP
(850 sq/ft)
3/4"CW-DROP
4" FD-B
4" W-UP
4" W-UP
6" RL-UP (4185 sq/ft)
4" WS-UP&DN
4" W-UP
4" WS-UP&DN4" WS-UP&DN
6" RL-UP (2232 sq/ft)
2" CW-UP
4" W-UP
3/4" CW-DROP
4" WS-UP&DN
4" W-UP
4" W-UP
3/4" CW-DROP TO
HOSE STATION
6" RL-UP
(4464 sq/ft)
4" FD-B
4" W-UP
6" RL-UP
(4464 sq/ft)
3/4" CW-DROP TO
HOSE STATION4" W-UP
3/4" CW-DROP
4" W-UP
4" WS-UP
4" WS-UP
4" W-UP
4" W-UP
4" W-UP
4" WS-UP
4" W-UP
4" WS-UP
4" W-UP
6" RL-UP (2790 sq/ft)
4" WS-UP
3/4" CW-DROP
4" W-UP
3" V-UP
4" WS-UP
10" RL-UP (10726 sq/ft)
3/4" CW-DROP
CO
4" FD-B
4" W-UP4" WS-UP&DN
6" RL-UP (4464 sq/ft)
4" FD-B
4" W-UP
6" RL-UP (4185 sq/ft)
4" WS-UP&DN
6" RL-UP (2232 sq/ft)
4" WS-UP&DN
1" CW-UP
4" WS-UP
6" RL-UP (4185 sq/ft)
4" WS-UP
4" WS-UP&DN
4" WS-UP&DN
4" W-UP
6" RL-UP (4464 sq/ft)
4" FD-B
4" WS-UP&DN
3/4" CW
6" R
L
4" W-DN
4" W-DN
CO
CO
CO
4" W
CO
CO
FCO
FCO
4" W
4" W-DN
4" W-DN
10" RL-UP (10726 sq/ft)
TRENCH DRAIN
FCO
FCO FCO
FCO
3" V
1 1/2" CW
FCO
FCO
3/4" CW-DROP
6" OFD-UP
6" OFD-UP
3/4" PRV
2" CW-DROP
1 1/2" CW
3/4" CW
3/4" CW-DROP
1-1/2" CW
1 1/2" CW
3/4" CW
3/4" PRV
3/4" CW3/4" CW
4" W
P-811P-811P-811
P-811
P-811
FCO
4" FD-B
4" FD-B
4" FD-B
4" FD-B
4" FD-B
4" FD-B
FCO
4" FD-B4" FD-B FCO
FCO
FCO
(2) 4" V-UP&DN
P-811
6" R
L 6"
R L
6"RL-UP (3500 sq/ft)
REFER TO CONCOURSE DRAWING
00PL101-A5 FOR CONTINUATION
4"FD-B
4"FD-B
8" RL
CO
CO
CO
CO
CO
CO
CO
6" RL
6" O
FD
6" R
L
8" R
L
6" O
FD
8" R
L 6"
O
FD
6" OFD
CO
CO
RUN HORIZONTAL RL AND
OFD PIPING AS TIGHT TO
EAST WALL AS POSSIBLE.
STACK OFD PIPING ABOVE RL
11.5
CO
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
4PL101
BLDG 4 FIRST FLOOR PLUMBING PLAN
PDF WJJune 30, 2011
Construction Documents 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERS / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERS, INC. / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_04
3/32" = 1'-0"1 BLDG 4 FIRST FLOOR PLAN
2 Addendum 2 07/29/11 5 Addendum 5 11/30/11
6 RFI 00375.1 6/22/1213
13 BULL 107 2/3/2014
SEE RFI 03691:
Revises location of waste and vent risers.
RFI-04364:
Revised Location
RFI-05441: As-built location is acceptable
File details come from the government source that posted it.