589A5-22-106_Replace_HVAC_Bldg_4_Drawings_05-15-24_1of 3.pdf
PDF 24 MB Posted
- Attached to
- 589A5-22-106, REPLACE BLDG4 HVAC
- Solicitation number
- 36C25524R0114_1
About this file
This document is a solicitation (Solicitation Number: 36C25524R0114_1) for the replacement of the HVAC system in Building 4 at the Colmery - O'Neil VA Medical Center in Topeka, Kansas.
The Department of Veterans Affairs, Veterans Integrated Service Network 15, is seeking construction services to install a new HVAC system and controls for Building 4. This is a 100% Service-Disabled Veteran Owned Small Business (SDVOSB) set-aside with a $45 million small business size standard. The construction magnitude is estimated to be more than $10 million and will be awarded on a best value basis. The period of performance is 540 calendar days after notice to proceed. A single site visit is scheduled for September 12, 2024, and questions are due by September 13, 2024. Proposals submitted by Teaming Arrangements other than VA Joint Ventures will not be considered.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R OA D
F
2 5
T101 T102
Colmery-O'Neil Veterans' Administration Medical Center
Replace HVAC & Associated Components - Building 4
US DEPARTMENT OF VETERANS AFFAIRS
VA Eastern Kansas Health Care System
VA PROJECT NUMBER: 589A5-22-106
OVERALL CAMPUS SITE PLAN, BUILDING NUMBER, AND PROJECT LOCATOR
CONTACT INFORMATION
DRAWING INDEX LEGEND
BUILDING NUMBER SHEET TYPE DESIGNATORS
0 = GENERAL
1 = PLANS
2 = ELEVATIONS
3 = SECTIONS
4 = LARGE-SCALE VIEWS
5 = DETAILS
6 = SCHEDULES & DIAGRAMS
7 = USER DEFINED
8 = USER DEFINED
9 = 3D REPRESENTATIONS
DISCIPLINE DESIGNATORS EXAMPLES
GI = GENERAL INFORMATION
GC = GENERAL CONTRACT
GJ = ICRA
GR = PICTURES
CS = CIVIL SITE
AD = ARCHITECTURAL DEMOLITION
AS = ARCHITECTURAL SITE
AE = ARCHITECTURAL ELEMENTS
FLOOR PLANS, ELEVATIONS, DETAILS
AI = ARCHITECTURAL INTERIORS
AG = ARCHITECTURAL GRAPHICS
AF = ARCHITECTURAL FINISHES
AC = ARCHITECTURAL CEILING PLAN
AW = ARCHITECTURAL WAYFINDING
AP = ARCHITECTURAL SPACE PLANNING
FLOOR PLANS & SCHEDULES
AL = ARCHITECTURAL LIFE SAFETY
DRAWINGS
HA = HAZARDOUS MATERIALS
SG = STRUCTURAL GENERAL
SF = STRUCTURAL FRAMING
MD = MECHANICAL DEMOLITION
MG = MECHANICAL GENERAL
MH = MECHANICAL HVAC
MP = MECHANICAL PIPING
PG = PLUMBING MEDICAL GAS
PL = PLUMBING FIXTURES
ED = ELECTRICAL DEMOLITION
EG = ELECTRICAL GENERAL
EL = ELECTRICAL LIGHTING
EP = ELECTRICAL POWER
FP = FIRE PROTECTION
FLOOR NUMBER ON PLAN SHEETS
SHEET NUMBER
##-XX-###
COR: WILLIAM McPHAIL
(785) 350-3111 Ext. 52982
WILLIAM.MCPHAIL@VA.GOV
A/E: DAVE HAUN
317-464-9090
DHAUN@DAENGINEERING.COM
PROJECT LOCATIONOVERALL CAMPUS
SHED
CARPORT
st
S
TR
E E
T
ROAD A
R O
A D
R O
A D
O
ROAD J
ROAD A
ROAD A
R O
A D
A
R O
A D
A
R O
A D
B
R O
A D
C
R O
A D
L
ROAD E
R O
A D
D
R O
A D
H
R O
A D
G
GAGE BLVD.
BUILDING
BU
IL
D
IN
G
SHED
SOLAR ENERGY FIELD
GAGE BLVD.
st
S
TR
E E
T
BLDG_NO
BLDG
P ro pe rty
L in e
P ro pe rty
L in e
Property Line
Property Line
Property Line
N
AREA OF WORK
GENERAL - COVER SHEET
4-GI-001
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
1061REDEH
ROAD
F
T102
SHED
SH
ED
SHED
ROAD A
R O
A D
A
R O
A D
L
ROAD E
R O
A D
D
R O
A D
H
R O
A D
G
SOLAR ENERGY FIELD
BLDG_NO
BLDG
P ro pe rty
L in e
Property Line
N
PROJECT BUILDING
STAGING AREA
TRAILER AND
STORAGE AREA
2 5
4-GI-002
CONSTRUCTION SITE PLANNING
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
LOGISTICS GENERAL NOTES:
A. SELECTED CONTRACTOR TO OBTAIN REQUIRED SECURITY CLEARANCES WITH THE
CONTRACTING OFFICER REPRESENTATIVE (COR) DURING SUBMITTAL PHASE. WORK WITHIN
THE BUILDING REQUIRES TIER ONE CLEARANCE.
B. BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION.
C. DEMOLITION AND CONSTRUCTION WORK SHALL NOT INTERFERE WITH OR REDUCE EXISTING
BUILDING SECURITY. CONTRACTOR SHALL WORK WITH COR FOR FINAL LOCATIONS AND TO
SCHEDULE FOR BUILDING SECURITY.
D. CONTRACTOR IS TO PROVIDE TEMPORARY PATH OF EMERGENCY EGRESS FOR AREAS
UNDER CONSTRUCTION
E. CONTRACTOR TO PROVIDE A GRAPHIC PLAN OF PROPOSED TEMPORARY EGRESS AND
PROTECTION OF STRUCTURES PRIOR TO COMMENCING WORK FOR OWNER AND ARCHITECT
APPROVAL. THE EGRESS PATH MUST HAVE PROTECTION FROM WORK ABOVE AND ADJACENT
TO THE PATH.
F. THOSE WISHING TO VISIT THE SITE SHALL NOTIFY THE COR WILLIAM MCPHAIL
(WILLIAM.MCPHAIL@VA.GOV (785) 350-3111 EXT. 52982 OR HIS DESIGNATED REPRESENTATIVE
A MINIMUM OF 1 WEEK PRIOR.
G. BUILDING HOURS ARE CURRENTLY 7:00AM - 5:00PM MONDAY THRU FRIDAY. ANY CHANGES TO
BUILDING HOURS WILL BE PROVIDED BY THE COR.
H. ALL CONSTRUCTION PERSONNEL MUST SIGN-IN EVERY DAY THAT THEY ARE ON SITE -
COORDINATE DESIRED PROCEDURE WITH COR.
I. NOISY WORK AND WORK PRODUCING NOXIOUS ODOR SHALL BE SCHEDULED 48 HOURS IN
ADVANCE AND COMPLETED OUTSIDE REGULAR BUILDING HOURS OR AS DIRECTED BY THE
COR. PROTECT MECHANICAL DUCTS AND AIR INTAKE FROM DUST, DEBRIS AND NOXIOUS
ODORS.
J. NO MATERIAL IS TO BE STAGED OR STORED IN THE BUILDING CORRIDORS AND CONTRACTOR
IS RESPONSIBLE FOR MAINTAINING ALL EXISTING PATHS OF EGRESS FROM THE BUILDING.
K. THE GENERAL CONTRACTOR MAY USE EXISTING STORAGE WITHIN THE BUILDING ONLY AS
DIRECTED BY COR.
L. ALL ROOF DRAINS SHOULD BE PROTECTED FROM DEBRIS. CONTRACTOR TO VERIFY CLEAN
CONDITION OF DRAINS AT COMPLETION OF THE PROJECT. IT IS RECOMMENDED THAT THE
CONTRACTOR DOCUMENT THE EXISTING CONDITION OF THE ROOF DRAINS PRIOR TO START
OF WORK.
M. CONTRACTOR PARKING TO BE IN PUBLIC LOTS OR AS DESIGNATED BY COR.
N. MATERIALS STORAGE LOCATIONS AS DESIGNATED BY COR.
CONSTRUCTION SCHEDULING NOTES:
1. THE PROJECT SHALL BE COMPLETED IN THE CALENDAR DAYS NOTED IN THE
CONTRACT.
2. THE GENERAL CONTRACTOR WILL PREPARE A GRAPHIC SCHEDULE FOR FINAL
APPROVAL BY THE COR PRIOR TO CONSTRUCTION START.
3. CONTRACTOR MUST COORDINATE SCHEDULE WITH THE COR AND OTHER
CONTRACTORS WORKING UNDER SEPARATE CONTRACTS IN ADJACENT
SPACES OF THE BUILDING.
4. THE GENERAL CONTRACTOR WILL PREPARE A CONSTRUCTION STAGING AND
SAFETY PLAN FOR FINAL APPROVAL BY THE COR PRIOR TO CONSTRUCTION
START.
UTILITY LOCATION AND ACCESS NOTES:
1. CONTRACTOR MUST CONTACT LOCAL UTILITY MARKING SERVICE TO LOCATE
AND MARK ALL UNDERGROUND UTILITIES WITHIN WORK AREA PRIOR TO ANY
DEMOLITION.
2. CONTRACTOR WILL HAVE ACCESS TO (COR) DESIGNATED 110V ELECTRICITY
AND WATER WHILE WORKING ON THE EXTERIOR OF THE BUILDING.
3. CONTRACTOR MAY HAVE ACCESS TO 110V ELECTRICITY, WATER, AND BUILDING
RESTROOMS WHILE WORKING ON THE INTERIOR OF THE BUILDING. (NOTIFY
COR PRIOR TO USING INTERIOR FACILITIES)
4. DESIGNATED RESTROOMS WILL BE AVAILABLE TO PERSONNEL WHO WORK ON
THE EXTERIOR, HOWEVER DUE TO SECURITY TO ENTER THE BUILDING IT IS
RECOMMENDED THAT THE CONTRACTOR PROVIDE A PORTABLE RESTROOM.
LOCATION TO BE IDENTIFIED BY COR.
5. ANY ADDITIONAL UTILITIES REQUIRED FOR DEMOLITION OR CONSTRUCTION
MUST BE PROVIDED BY THE CONTRACTOR.
CONSTRUCTION DEBRIS NOTES:
1. CONSTRUCTION DEBRIS MUST BE CONTAINED WITHIN THE BOUNDARY
AREA AT ALL TIMES.
2. CONSTRUCTION DEBRIS MUST BE MONITORED AND SECURED AT ALL
TIMES
3. VA MANDATED RECYCLING FORMS MUST BE KEPT UP TO DATE.
4. DUMPING OF DEMOLITION OR CONSTRUCTION LIQUIDS IS PROHIBITED
IN EXISTING PLUMBING FIXTURES UNLESS DIRECTED OTHERWISE BY
COR.
5. CONSTRUCTION DEBRIS MUST NOT BE STORED OR STOCK PILED ON
THE EXISTING ROOF.
6. THE CONTRACTOR IS RESPONSIBLE FOR THE CONTINUED USE AND
MAINTENANCE OF THE ROOF DRAINAGE ASSEMBLIES.
LOGISTICS KEY NOTES:
1. TEMPORARY SAFETY FENCING TO BE INSTALLED AROUND THIS AREA.
2. CONTRACTOR TO CONTACT VA COR FOR ANY LANE CLOSURES REQUIRED FOR MACHINERY ACCESS.
3. GENERAL CONTRACTOR AND SUBCONTRACTORS TO CHECK IN THROUGH COVID-19 SCREENING
AREA, FOLLOWING ALL VA GUIDELINES.
4. BUILDING ACCESS POINT
5. STORAGE OF MATERIALS, OR CONSTRUCTION WORK IS THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR. PHOTO DOCUMENT AND REPORT ANY EXISTING DAMAGE TO COR PRIOR TO START OF CONSTRUCTION. OFF-SITE STORAGE OF BUILDING MATERIALS MUST BE APPROVED BY THE VA COR
PRIOR TO REMOVAL.
6. SUGGESTED DUMPSTER LOCATIONS. PRIOR TO START OF ON-SITE MOBILIZATION. THE CONTRACTOR IS REQUIRED TO VERIFY LOCATION AND TEST/INSPECT UTILITIES AND UNDERGROUND SPRINKLER SYSTEMS. CONTRACTOR TO PROTECT ALL SPRINKLERS AND IN GROUND SYSTEMS. COST TO REPAIR
DAMAGE TO SPRINKLER SYSTEM INCURRED DURING THE PROJECT WILL BE THE CONTRACTOR'S
SOLE RESPONSIBILITY.
7. BUILDING NOT IN CONTRACT. SHOWN FOR CAMPUS CLARITY.
8. SUGGESTED TRASH CHUTE LOCATION FOR TRASH AND DEBRIS FROM ROOF DEMO.
7 7
CONSTRUCTION SITE PLANNING PLAN
NO SCALE
2REDEH
UPUP
E
D1
D
F
7 8 9 10 11
DNDN
UP
UPUP
A
B
E
C
D1
D
F
G
H
J
1 2 3 4 5 6 7 8 9 10 16 17 18 19 20 21 22
23 24 25
1211 13 14 15
C0-C1A0-C1B0-C1 B09
B09A
B09B
C17
C17A
C17B
C17F C18
C19E
C15 C15B
C15A
C19
C23 C22
A14
A24A24A
A24B
A13A0-S1
A12F A11
A2E A01E
B04B05B06
B07E
B08FB08
B07 B03
A01A
A01A02 C21 C20
A0-E9
AE-MECH BASEMENT SPACE DRIVER AREA - B...
NO NAME NET AREA
COMMON SPACE
B10 MECHANICAL 1025 SF
1025 SF
AE-BASEMENT SPACE DRIVER AREA - BY ROOM
NO NAME NET AREA
CENTRALIZED STAFF FAC
A13 STAFF RESTROOM 49 SF
A24 FEMALE STAFF LOUNGE 143 SF
A24A LOCKER ROOM 209 SF
A24B RESTROOM 137 SF
C15 MALE STAFF LOUNGE 142 SF
C15A LOCKER ROOM 200 SF
C15B RESTROOM 115 SF
995 SF
COMMON SPACE
A0-C1 CORRIDOR 639 SF
A0-E9 ELEVATOR 92 SF
A0-S1 STAIR 1 147 SF
A01E ELEC. CLOSET 7 SF
A2E ELEC. CLOSET 7 SF
A11 HOUSEKEEPING 83 SF
A12 CLOSET 26 SF
A12F FIRE CLOSET 3 SF
A14 STORAGE 260 SF
B0-C1 CORRIDOR 482 SF
B07 MECHANICAL 214 SF
B07E ELEC. CLOSET 7 SF
B08F FIRE CLOSET 3 SF
B09 VESTIBULE 38 SF
B09A CLOSET 24 SF
B09B STAIR 3 105 SF
B10 MECHANICAL 1025 SF
C0-C1 CORRIDOR 488 SF
C17 VESTIBULE 49 SF
C17A STORAGE 26 SF
C17B STAIR 2 116 SF
C17F FIRE CLOSET 2 SF
C19 FIRE PANEL ROOM 619 SF
C19E ELEC. CLOSET 8 SF
4470 SF
IRM
C20 IT CLOSET 131 SF
131 SF
LINEN SERVICE
B08 SOILED LINEN 262 SF
C18 SOILED LINEN 260 SF
523 SF
NURSING SVC ADMIN
B03 CLINICAL NURSE LEADER 151 SF
151 SF
PSYCHIATRY ADMINISTRATION
C23 OFFICE 133 SF
133 SF
PSYCHOLOGY
C21 OFFICE 130 SF
C22 OFFICE 138 SF
268 SF
REHAB MEDICINE
B04 VOC. REHAB & EMPLOYMENT 140 SF
B05 VOC. REHAB & EMPLOYMENT 137 SF
B06 VOC. REHAB & EMPLOYMENT 123 SF
400 SF
VSO/VET ASSISTANCE
A01 AFGE 300 SF
A01A STORAGE 73 SF
A02 AFGE INTERVIEW ROOM 153 SF
527 SF
NO NAME NET AREA
PHASE 1 PHASE 2
SEE ENLARGED PLAN
ABOVE ON THIS SHEET.
PHASE 1
PHASE 1
4-GI-1B3
PHASING PLAN BASEMENT FLOOR
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
PHASING PLAN BASEMENT FLOOR
NO SCALE
REDEH
DN
DN
DN
DN
UP
UP
UP
UPUP UP
A
B
E
C
D1
D
F
G
H
J
1 2 3 4 5 6 7 8 9 10
16 17 18 19 20 21 22 23 24 25
13 14
A1-S1
A101
A138A
A136
A139
A136A
A137
A141
A143
A140
A144 A145
A102
B134
A102EA103E
A103
A1-C4
A138
B112
B104B105
B1-C2
B131
B108
B132
B132A
B130
B129
B129A
B128
B106 B107
B125F
B1-S3
B125
B125A
B126
B126A
B127
B127A
B133
B123
B115E
B122
B113
B114
B115
B121E
B116
B116A
B117B118
B121
B121AB120
B109
B119
B119A
A101A
C1-3
C163E
C163 C164
C165
C166 C167
C168
C169C169AC170
C148
C149
C150
C151
C153
C154 C155
C156
C157
C158C158F
C162
C161
C160C142A
C145
C146B
C146
C146A
C143
C143A
C143B
C142
C144
C175A C174A
C172
C171
C170E
C152
C173
C174C175
C147
C146C C1-C1A1-C2
A1-C1
A1-C3
B110
C1-C2
B1-C1
B1-C4
B1-C3
C144A
C163A
A1-E9
C1-S2
PHASE 5
PHASE 6
AE-LEVEL 1 SPACE DRIVER AREA - BY ROOM
NO NAME NET AREA
B116 PATIENT ROOM 254 SF
B116A RESTROOM 47 SF
B117 PATIENT ROOM 305 SF
B118 PATIENT ROOM 270 SF
B119 PATIENT ROOM 259 SF
B119A RESTROOM 71 SF
B120 PATIENT ROOM 252 SF
B121 PATIENT ROOM 180 SF
B121A RESTROOM 46 SF
B122 SOILED UTILITY 65 SF
B123 CLEAN LINEN 70 SF
B125 PATIENT ROOM 129 SF
B125A RESTROOM 52 SF
B126 PATIENT ROOM 218 SF
B126A RESTROOM 51 SF
B127 PATIENT ROOM 235 SF
B127A RESTROOM 47 SF
B128 PATIENT ROOM 240 SF
B129 PATIENT ROOM 261 SF
B129A RESTROOM 53 SF
B130 TV ROOM 270 SF
B131 PHONE ALCOVE 19 SF
B132 CONFERENCE 252 SF
B132A STORAGE 65 SF
B133 SOCIAL WORK OFFICE 162 SF
B134 COMF. CARE CLOSET 78 SF
8106 SF
CANTEEN SERVICE
A138A VENDING 79 SF
79 SF
CENTRALIZED STAFF FAC
A139 MEN'S STAFF RESTROOM 47 SF
A140 STAFF RESTROOM 34 SF
A141 STAFF LOUNGE 230 SF
A143 UNIVERSAL WASTE STORAGE 45 SF
C149 STAFF ONLY 53 SF
C166 STAFF RESTROOM 33 SF
442 SF
COMMON SPACE
A1-C1 CORRIDOR 186 SF
A1-C2 CORRIDOR 107 SF
A1-C3 CORRIDOR 890 SF
A1-C4 CORRIDOR 165 SF
A1-E9 ELEV#9 97 SF
A1-S1 STAIR 1 172 SF
A102 EQUIPMENT ROOM 95 SF
A102E ELEC. CLOSET 7 SF
A103E ELEC. CLOSET 9 SF
A136 SOLARIUM 964 SF
A136A ENGINEERING 165 SF
A137 CONFERENCE ROOM 254 SF
A144 MEN 48 SF
A145 WOMEN 54 SF
B1-S3 STAIR 3 174 SF
B115E ELEC. CLOSET 7 SF
B121E ELEC. CLOSET 19 SF
B125F FIRE CLOSET 4 SF
C1-3 WOMEN'S HEALTH CLINIC 1149 SF
C1-C2 CORRIDOR 570 SF
C1-S2 STAIR 2 170 SF
C148 RESTROOM 53 SF
C158F FIRE CLOSET 3 SF
C161 HOUSEKEEPING 23 SF
C162 HOUSEKEEPING 65 SF
C163 E
ELEC. CLOSET 19 SF
C165 WOMEN 34 SF
C170 E
ELEC. CLOSET 8 SF
5512 SF
IRM
C143 A
IT CLOSET 7 SF
C146 C
NETWORK CLOSET 15 SF
22 SF
LOBBY SPACE
A101 LOBBY 520 SF
A101A VESTIBULE 144 SF
664 SF
MED SERVICE ADMIN
C150 CONFERENCE 302 SF
302 SF
RECREATIONAL THERAPY
A138 SDTP CLASSROOM 972 SF
972 SF
REHAB MEDICINE
C174 GROUP ROOM 449 SF
C174 A
STORAGE 29 SF
C175 RECREATION CLINIC 398 SF
C175 A
STORAGE 36 SF
912 SF
SOCIAL WORK
C151 SOCIAL WORKER 120 SF
C153 OEF/OIF/OND CASE MANAGER 95 SF
C154 OEF/OIF/OND PROGRAM
MANAGER
339 SF
C155 OEF/OIF/OND CASE MANAGER 252 SF
C156 OEF/OIF/OND NURSE CASE
MANAGER
94 SF
C158 EXAM ROOM 119 SF
AE-LEVEL 1 SPACE DRIVER AREA - BY ROOM
NO NAME NET AREA
C144 A
CLOSET 14 SF
C145 RESTROOM 55 SF
C146 RESIDENT ROOM 127 SF
C146 A
CLOSET 8 SF
C146 B
HALLWAY 30 SF
878 SF
BEDS MH/BEHAVIORAL MED
A103 NURSE MANAGER 177 SF
B1-C1 CORRIDOR 302 SF
B1-C2 CORRIDOR 704 SF
B1-C3 CORRIDOR 542 SF
B1-C4 CORRIDOR 146 SF
B104 QUIET ROOM 150 SF
B105 MULTI-PURPOSE ROOM 104 SF
B106 EXAM ROOM 160 SF
B107 MEDICINE 73 SF
B108 NURSE'S STATION 219 SF
B108A NURSING 115 SF
B109 BREAK ROOM 46 SF
B110 DAYROOM 616 SF
B111 KITCHEN 151 SF
B112 DINING ROOM 457 SF
B113 NOURISHMENT 99 SF
B114 HOUSEKEEPING 34 SF
B115 LAUNDRY 57 SF
AE-LEVEL 1 SPACE DRIVER AREA - BY ROOM
NO NAME NET AREA
ACS-PRIMARY CARE
C1-C1 CORRIDOR 466 SF
C147 SUPPLIES 106 SF
C152 PSYCHOLOGIST 147 SF
C157 EXAM ROOM 136 SF
C160 STAFF WORK ROOM 37 SF
C163 EXAM ROOM 128 SF
C163 A
ALCOVE 12 SF
C164 SOCIAL WORKER 143 SF
C167 EXAM ROOM 274 SF
C168 CONFERENCE ROOM 368 SF
C169 CARE MANAGER 280 SF
C169 A
WOMEN'S WAITING ROOM 187 SF
C170 EXAM ROOM 162 SF
C171 WOMENS HEALTH RECEPTION 217 SF
C172 STORAGE 120 SF
C173 MEDICINE 63 SF
2847 SF
BEDS HOPTEL
C142 HOPTEL 416 SF
C142 A
CLOSET 4 SF
C143 KITCHEN 74 SF
C143 B
LAUNDRY 15 SF
C144 RESIDENT ROOM 135 SF
PHASE 2 PHASE 2
4-GI-114
PHASING PLAN 1ST FLOOR 1020 SF
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
PHASING PLAN 1ST FLOOR
4REDEH
UP UP
UP
A
B
E
C
D1
D
F
G
H
J
1 2 3 4 5 6 7 8 9 10
16 17 18 19 20 21 22
23 24 25
13 14
A201
A236
A271
A234F
A2 -S
A238
A237
A269 C268 C267 C265
C239A
C240 C239
C249
C250
C256
C255A
C254
C253A
C253
C263 C255
C262
C256E
C251E
C257
C258
C2-S2
C247
C243A
C243
C242
C246A
C246
C247F
C247G
C244A
C264
C2-C1
C2-C2
C252
C241
C2-C3
C251A C251
C244
C247A
B231 A234A234A
A202EA203E
B204B205B206
B232
B230
B225F
B2-C1
B225
B225A
B223
B222
B221E
B215EB2-C3
B213
B214
B215
B216A
B217B218
B226A
B226
B209 B208
B207 A203
B232A
B233
B229A
B229
B227A
B227 B228
B2 -S
B218A
B219 B220A B220
B221
B216 A202 A270
B210B212
B2-C4
B2-C2
C266
C261
C2-C4
C259
A2-9
PHASE 4 PHASE 3A
PHASE 3B
SWING SPACE
AE-LEVEL 2 SPACE DRIVER AREA - BY ROOM
NO NAME NET AREA
B220A RESTROOM 46 SF
B221 OFFICE 181 SF
B222 SOILED LINEN 66 SF
B223 STORAGE 72 SF
B225 CHANGING ROOM 130 SF
B225A CHANGING RESTROOM 52 SF
B226 PATIENT ROOM 217 SF
B226A RESTROOM 49 SF
B227 PATIENT ROOM 239 SF
B227A RESTROOM 45 SF
B228 PATIENT ROOM 244 SF
B229 PATIENT ROOM 262 SF
B229A RESTROOM 56 SF
B230 SOCIAL ROOM 264 SF
B231 TELEPHONE ALCOVE 20 SF
B232 PATIENT ROOM 253 SF
B232A RESTROOM 66 SF
B233 PATIENT ROOM 166 SF
C2-C1 CORRIDOR 308 SF
C2-C2 CORRIDOR 463 SF
C2-C3 CORRIDOR 540 SF
C2-C4 CORRIDOR 251 SF
C239 STAFF PSYCHOLOGIST 162 SF
C239A RESTROOM 66 SF
C240 PATIENT ROOM 266 SF
C241 EQUIPMENT 19 SF
C242 RN OFFICE 270 SF
C243 PATIENT ROOM 256 SF
C243A RESTROOM 53 SF
C244 PATIENT ROOM 250 SF
C244A RESTROOM 49 SF
C246 PATIENT ROOM 204 SF
C246A RESTROOM 49 SF
C247 PATIENT ROOM 131 SF
C247A RESTROOM 51 SF
C247G PATIENT ROOM 253 SF
C249 LINEN & OXYGEN STORAGE 70 SF
C250 SOILED LINEN UTILITY ROOM 68 SF
C251 PATIENT ROOM 180 SF
C251A RESTROOM 53 SF
C252 PATIENT ROOM 245 SF
C253 PATIENT ROOM 263 SF
C253A RESTROOM 71 SF
C254 PATIENT ROOM 275 SF
C255 PATIENT ROOM 304 SF
C255A RESTROOM 48 SF
C256 PATIENT ROOM 265 SF
C257 PATIENT LAUNDRY 57 SF
C259 NURSE MANAGER 102 SF
C261 DINING ROOM 607 SF
C262 LIVING ROOM 617 SF
C263 NURSES STATION 487 SF
C264 MEDICINE 79 SF
C265 KITCHEN 70 SF
C267 CONFERENCE 213 SF
16205 SF
CENTRALIZED STAFF FAC
A236 STAFF RESTROOM 46 SF
A237 STAFF RESTROOM 48 SF
A238 BREAK ROOM 220 SF
A271 STAFF RESTROOM 46 SF
B204 STAFF LOUNGE 156 SF
516 SF
COMMON SPACE
A2-9 ELEVATOR 109 SF
A2-S1 STAIR 1 177 SF
A3-1 STAIR 1 129 SF
A201 ELEVATOR LOBBY 664 SF
A202E ELEC. CLOSET 7 SF
A203E ELEC. CLOSET 8 SF
A234F FIRE CLOSET 3 SF
A272 HALLWAY 117 SF
A301 MECHANICAL PENTHOUSE 1342 SF
B2-S3 STAIR 3 177 SF
B214 HOUSEKEEPING 40 SF
B215E ELEC. CLOSET 10 SF
B221E ELEC. CLOSET 19 SF
B225F FIRE CLOSET 5 SF
C2-S2 STAIR 2 175 SF
C247F FIRE CLOSET 3 SF
C251E ELEC. CLOSET 19 SF
C256E ELEC. CLOSET 8 SF
C258 HOUSEKEEPING 40 SF
3051 SF
IRM
C266 NETWORK CLOSET 29 SF
29 SF
SOCIAL WORK
C268 SOCIAL WORK OFFICE 157 SF
157 SF
20360 SF
AE-LEVEL 2 SPACE DRIVER AREA - BY ROOM
NO NAME NET AREA
1 CHASE 403 SF
403 SF
BEDS MH/BEHAVIORAL MED
A202 SUPPLY ROOM 96 SF
A203 NURSE MANAGER 177 SF
A234 FULL OXYGEN STORAGE 26 SF
A234A EMPTY OXYGEN STORAGE 33 SF
A269 OFFICE 127 SF
A270 OFFICE 141 SF
B2-C1 CORRIDOR 471 SF
B2-C2 CORRIDOR 463 SF
B2-C3 CORRIDOR 541 SF
B2-C4 CORRIDOR 250 SF
B205 LINEN ROOM 106 SF
B206 HYDROTHEREPY 166 SF
B207 MEDICINE 70 SF
B208 NURSE STATION 474 SF
B209 NOURISHMENT 52 SF
B210 DINING ROOM 622 SF
B212 DAY ROOM 609 SF
B213 KITCHEN 101 SF
B215 LAUNDRY 53 SF
B216 PATIENT ROOM 259 SF
B216A RESTROOM 49 SF
B217 PATIENT ROOM 311 SF
B218 PATIENT ROOM 274 SF
B218A RESTROOM 72 SF
B219 PATIENT ROOM 265 SF
B220 PATIENT ROOM 252 SF
PHASE 2
PHASE 2
4-GI-125
PHASING PLAN 2ND FLOOR
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
PHASING PLAN 2ND FLOOR
5REDEH
AE-PENTHOUSE SPACE DRIVER AREA - BY...
NO NAME NET AREA
COMMON SPACE
A3-1 STAIR 1 129 SF
A301 MECHANICAL PENTHOUSE 1342 SF
1471 SF
PHASE 6
PHASE 3APHASE 4
PHASE 4 PHASE 3A
DN
1 2 3 4 5 6 9 11 13 16 18 20 22 24
A
B
C
D
F
H
7 8 1210 14 17 19 21 23 25
E
G
I
4-GI-1R6
PHASING PLAN ROOF &
PENTHOUSE
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
PHASING PLAN ROOF & PENTHOUSE
6REDEH
1. THIS PHASE WORK TO BE DONE DURING EVENING HOURS AND/OR OVER WEEKEND HOURS.
2. DOOR COVERING TO MEET/EXCEED TOPEKA VAMC ICRA STANDARDS. VERIFY WITH COR.
SPECIALTY NOTES:
A. SECURITY
1. CONTRACTOR SHALL NOT LEAVE DOORS PROPPED OPEN.
2. CONTRACTOR SHALL NOT LEAVE TOOLS OR LADDERS UNATTENDED.
3. CONTRACTOR SHALL NOT LEAVE ELECTRICAL OR DATA PANELS EXPOSED.
B. PHOTOGRAPHY
1. NO PHOTOGRAPHY OF VA PREMISES IS ALLOWED WITHOUT WRITTEN PERMISSION OF THE
COR. IF PERMISSION IS GRANTED BY THE COR, NO PHOTOGRAPHY IS PERMITTED OF
PERSONNEL, PATIENTS, COMPUTER SCREENS, LICENSE PLATES, OR ANY OTHER SENSITIVE
MATERIAL AS DETERMINED BY THE COR.
C. BADGING
1. ALL CONTRACTOR PERSONNEL ARE REQUIRED TO DISPLAY VA BADGE WHEN WORKING ON
STATION.
2. TWO-WEEK NOTICE IS REQUIRED FOR BADGING OF CONTRACTOR PERSONNEL REQUIRING A
FLASH PASS/BADGE .
D. KEYS
1. COORDINATE WITH VA COR FOR ACCESS AND ISSUING OF KEYS.
E. JOBSITE PLAN
1. JOBSITE PLAN MUST BE SUBMITTED PRIOR TO COMMENCEMENT OF WORK
a. INCLUDES
1. ENTRANCES USED
2. MATERIAL MOVEMENT PLAN
3. RESTROOMS TO BE USED
4. LIST OF SUBCONTRACTORS
5. SITE PLAN (LAYDOWN AREA, JOBSITE TRAILER LOCATION, DUMPSTER LOCATION)
6. PERSONNEL ON SITE
F. TRAILER STORAGE
1. CONTRACTORS ARE REQUIRED TO COORDINATE TRAILER STORAGE LOCATION WITH COR.
G. CONTRACTOR SHALL NOTIFY COR OF ANY MATERIAL REMOVED CONTAINING EE# OR MAXIMO
NUMBER.
1. CONTRACTOR SHALL NOTIFY COR OF ANY NEW EQUIPMENT AND/OR SPECIFIC
REQUIREMENTS FOR EQUIPMENT (I.E. SPECIAL OUTLETS, ADEQUATE BREAKER SIZE, ETC.).
(MAKE, MODEL, SERIAL NUMBER)
H. UTILITY SHUTDOWNS
1. MUST BE COORDINATED WITH COR 21 DAYS IN ADVANCE.
I. FIRESTOPPING
1. INSTALL TEMPORARY FIRESTOPPING IN ALL NEW CORE DRILLED PENETRATIONS IN FLOOR
AND WALLS. ENSURE FIRESTOPPING IS MAINTAINED THROUGHOUT CONSTRUCTION UNTIL
PENETRATIONS ARE PERMANENTLY FIRE STOPPED.
K. FIRE ALARM/SPRINKLER
1. IF FIRE ALARM AND/OR SPRINKLER SYSTEM IS DISABLED DURING CONSTRUCTION,
HEAT DETECTION MUST BE PROVIDED. SIEMENS MUST MAKE FINAL TERMINATIONS AND
PROGRAM INTO EXISTING FIRE ALARM SYSTEM.
J. ILSM
1. TEMPORARY FIRE EXTINGUISHERS SHALL BE APPROPRIATELY MOUNTED AND SPACED
DURING CONSTRUCTION FOR HOUSEKEEPING AND SAFETY REQUIREMENTS.
a. TRAVEL DISTANCE FROM ANY POINT OF THE PROTECTED AREA TO THE NEAREST FIRE
EXTINGUISHER SHALL NOT EXCEED 75 FEET.
K. EXIT PATHS MUST BE LITTER/DEBRIS FREE
L. THE CONTRACTOR IS RESPONSIBLE FOR MOVING, STORING AND PROTECTING ALL EXISTING
FURNITURE AND EQUIPMENT IN EACH AREA FOR THE DURATION OF THE PROJECT.
FURNITURE AND EQUIPMENT DAMAGED BY THE CONTRACTOR WILL BE REPLACED OR
RESTORED TO COMPLETE FUNCTIONALITY AND APPEARANCE BY THE CONTRACTOR AT NO
COST TO THE VA.
M. CONTRACTOR IS REQUIRED TO HAVE A DECON SHOWER FOR ALL WORK.
N. ALL WORK IN CORRIDORS HAVE TO BE REMOVED BEFORE 6:00AM EACH MORNING.
DNDN
UP
UPUP
C0-C1A0-C1B0-C1 B09
B09A
B09B
C17
C17A
C17B
C17F C18
C19E
C15 C15B
C15A
C19
C23 C22
A14
A24A24A
A24B
A13A0-S1
A12F A11
A2E A01E
B04B05B06
B07E
B08FB08
B07 B03
A01A
A01A02 C21 C20
A0-E9 UPUP
UP
UP
UP
UPUP UP
A1-S1
A101
A138A
A136
A139
A136A
A137
A141
A143
A140
A144 A145
A102
B134
A102EA103E
A103
A1-C4
A138
B112
B104B105
B1-C2
B131
B108
B132
B132A
B130
B129
B129A
B128
B106 B107
B125F
B1-S3
B125
B125A
B126
B126A
B127
B127A
B133
B123
B115E
B122
B113
B114
B115
B121E
B116
B116A
B117B118
B121
B121AB120
B109
B119
B119A
A101A
C1-3
C163E
C163 C164
C165
C166 C167
C168
C169C169AC170
C148
C149
C150
C151
C153
C154 C155
C156
C157
C158C158F
C162
C161
C160C142A
C145
C146B
C146
C146A
C143
C143A
C143B
C142
C144
C175A C174A
C172
C171
C170E
C152
C173
C174C175
C147
C146C C1-C1A1-C2
A1-C1
A1-C3
B110
C1-C2
B1-C1
B1-C4
B1-C3
C144A
C163A
A1-E9
C1-S2
UP UP
UP
A201
A236
A271
A234F
A2 -S
A238
A237
A269 C268 C267 C265
C239A
C240 C239
C249
C250
C256
C255A
C254
C253A
C253
C263 C255
C262
C256E
C251E
C257
C258
C2-S2
C247
C243A
C243
C242
C246A
C246
C247F
C247G
C244A
C264
C2-C1
C2-C2
C252
C241
C2-C3
C251A C251
C244
C247A
B231 A234A234A
A202EA203E
B204B205B206
B232
B230
B225F
B2-C1
B225
B225A
B223
B222
B221E
B215EB2-C3
B213
B214
B215
B216A
B217B218
B226A
B226
B209 B208
B207 A203
B232A
B233
B229A
B229
B227A
B227 B228
B2 -S
B218A
B219 B220A B220
B221
B216 A202 A270
B210B212
B2-C4
B2-C2
C266
C261
C2-C4
C259
A2-9
UP
4-GJ-507
ICRA PLAN BASEMENT, FIRST,
AND SECOND FLOORS
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
ICRA PLAN BASEMENT, FIRST, AND SECOND FLOORS
7REDEH
AS SCHEDULED
ACOUSTICAL CEILING
2' X 4' SUSPENDED
WALL CONST. TYPES (DETAILS)
TYPE A
BASE @ BOTH SIDES
4" RUBBER COVE
W A
LL
H
EI
G H T
V
ER
IE
S
TYPE B
C
EI
LI
N G
H
EI
G H T
'-0
ON FLOOR PLAN.
FI
EL
D V
ER
IF
Y
C
EI
LI
N G
H
EI
G H T
'-0
4 7/8"4 7/8"
W A
LL
H
EI
G H T
V
ER
IE
S
FI
EL
D V
ER
IF
Y
TO MATCH EXISTING AREA
ROOF METAL DECKING
AS SCHEDULED
ACOUSTICAL CEILING
2' X 4' SUSPENDED
ON FLOOR PLAN.
HARD WALL ICRA
BARRIERS ARE
REQUIRED FOR ICRA
AND SHALL HAVE A 1
HR FIRE RATING AND
SOUND ATTENUATION.
BASIS OF DESIGN:
STARC SYSTEMS FIRE
BLOCK WALL. WALL TO
EXTEND TO ROOF METAL
DECKING
4" RUBBER COVE TO
MATCH EXISTING AREA
BASE @ BOTH SIDES
HARD WALL ICRA
BARRIERS ARE
REQUIRED FOR ICRA
AND SHALL HAVE A 1
HR FIRE RATING AND
SOUND ATTENUATION.
BASIS OF DESIGN:
STARC SYSTEMS FIRE
BLOCK WALL. WALL TO
EXTEND TO ROOF METAL
DECKING
GENERAL NOTES:
LOW RISK
OFFICE AREAS
PATIENT RISK GROUPS
MEDIUM RISK HIGH RISK HIGHEST RISK
CARDIOLOGY CCU ANY AREA CARING FOR
ECHOCARDIOGRAPHY
ENDOSCOPY
NUCLEAR MEDICINE
PHYSICAL THERAPY
RADIOLOGY/MRI
RESPIRATORY THERAPY
EMERGENCY ROOM
LABOR & DELIVERY
LABORATORY (SPECIMEN)
NEWBORN NURSERY
OUTPATIENT SURGERY
PEDIATRICS
IMMUNOCOMPROMISED PATIENTS
BURN UNIT
CARDIAC CATH LAB
CENTRAL STERILE SUPPLY
INTENSIVE CARE UNITS
MEDICAL UNIT
PHARMACY
POST ANESTHESIA CARE UNIT
SURGICAL UNITS
NEGATIVE PRESSURE ISOLATION ROOMS
ONCOLOGY
OPERATING ROOMS INCLUDING
C-SECTION ROOMS
LOW RISK GROUP
CONSTRUCTION PROJECT TYPE
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP
RISK RELATED GROUP TYPE A TYPE B TYPE C TYPE D
I II II III/IV
II
II III/IV
III/IV
III
III/IV
IV
IV
IV
I
I
II
CONSTRUCTION PROJECT BY PATIENT RISK
IC MATRIX - CLASS OF PRECAUTIONS:
INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK
NOTE:
LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
INSPECTION AND NON-INVASIVE ACTIVITIES
TYPE A
SMALL SCALE, SHORT DURATION ACTIVITIES
TYPE B
WHICH CREATES MINIMAL DUST.
WORK THAT GENERATES A MODERATE TO
TYPE C
HIGH LEVEL OF DUST OR REQUIRES DEMOLITION
OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES
MAJOR DEMOLITION AND CONSTRUCTION
TYPE D
PROJECTS
MATRIX OF PRECAUTIONS FOR
CONSTRUCTION & RENOVATION
I R AC (ICRA)
ROOM ELEVATION
AREA UNDER
FRAMED
PICTURE
OF
C.O.R.
ICRA, ILSM
FIRE WATCH
MISC. FORMS
PAPER
CADDY
CONSTRUCTION
RESTRICTED AREA
THIS IS A
CONST. SUPERVISOR
NAME AND
CELL PHONE
XXXXXX XXXX XXXX
CHILLER PLANT AFTER HOURS
CONTACT PHONE 53230
FIRE EMERGENCY DIAL 4911
XXXXXX XXXX XXXX
XXXXXX XXXX XXXX
WITH CONTACT
INFORMATION
INTERIM LIFE SAFETY MEASURES:
INFECTION CONTROL RISK ASSESSMENT:
PICRA:
UTILITIES SHUT-DOWNS:
ICRA
ILSM
TYPICAL IDEAL
CONSTRUCTION LAYOUT
CLASS III
CROSS-SECTION 'A-A'
CROSS-SECTION 'A-A'
TYPICAL ALTERNATIVE
CONSTRUCTION LAYOUT
CLASS III
CLASS III (ALTERNATE)
CLASS III
1. REMOVE OR ISOLATE H.V.A.C. SYSTEM IN AREA WHERE WORK IS BEING DONE TO
PREVENT CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS IE. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL
AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH
PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR
VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS IF INDICATED.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
6. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL
DEPARTMENT AND THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL SERVICES
DEPARTMENT.
1. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
2. VACUUM WORK AREA WITH HEPA FILTERED VACUUM.
3. WET MOP AREA WITH DISINFECTANT.
4. REMOVE ISOLATION OF H.V.A.C. SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
PRIOR TO ANY CONSTRUCTION
POST CONSTRUCTION
C
LA
SS
II
4-GJ-508
TYPE III ICRA CONSTRUCTION
DETAILS
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
1068REDEH
2' X 4' SUSPENDED
WALL CONST. TYPES (DETAILS)
TYPE A
BASE @ BOTH SIDES
4" RUBBER COVE
W A
LL
H
EI
G H T
V
ER
IE
S
TYPE B
C
EI
LI
N G
H
EI
G H T
'-0
ON FLOOR PLAN.
FI
EL
D V
ER
IF
Y
C
EI
LI
N G
H
EI
G H T
'-0
4 7/8"4 7/8"
W A
LL
H
EI
G H T
V
ER
IE
S
FI
EL
D V
ER
IF
Y
TO MATCH EXISTING AREA
ROOF METAL DECKING
AS SCHEDULED
ACOUSTICAL CEILING
2' X 4' SUSPENDED
ON FLOOR PLAN.
HARD WALL ICRA
BARRIERS ARE
REQUIRED FOR ICRA
AND SHALL HAVE A 1
HR FIRE RATING AND
SOUND ATTENUATION.
BASIS OF DESIGN:
STARC SYSTEMS FIRE
BLOCK WALL. WALL TO
EXTEND TO ROOF METAL
DECKING
4" RUBBER COVE TO
MATCH EXISTING AREA
BASE @ BOTH SIDES
HARD WALL ICRA
BARRIERS ARE
REQUIRED FOR ICRA
AND SHALL HAVE A 1
HR FIRE RATING AND
SOUND ATTENUATION.
BASIS OF DESIGN:
STARC SYSTEMS FIRE
BLOCK WALL. WALL TO
EXTEND TO ROOF METAL
DECKING
GENERAL NOTES:
LOW RISK
OFFICE AREAS
PATIENT RISK GROUPS
MEDIUM RISK HIGH RISK HIGHEST RISK
CARDIOLOGY CCU ANY AREA CARING FOR
ECHOCARDIOGRAPHY
ENDOSCOPY
NUCLEAR MEDICINE
PHYSICAL THERAPY
RADIOLOGY/MRI
RESPIRATORY THERAPY
EMERGENCY ROOM
LABOR & DELIVERY
LABORATORY (SPECIMEN)
NEWBORN NURSERY
OUTPATIENT SURGERY
PEDIATRICS
IMMUNOCOMPROMISED PATIENTS
BURN UNIT
CARDIAC CATH LAB
CENTRAL STERILE SUPPLY
INTENSIVE CARE UNITS
MEDICAL UNIT
PHARMACY
POST ANESTHESIA CARE UNIT
SURGICAL UNITS
NEGATIVE PRESSURE ISOLATION ROOMS
ONCOLOGY
OPERATING ROOMS INCLUDING
C-SECTION ROOMS
LOW RISK GROUP
CONSTRUCTION PROJECT TYPE
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP
RISK RELATED GROUP TYPE A TYPE B TYPE C TYPE D
I II II III/IV
II
II III/IV
III/IV
III
III/IV
IV
IV
IV
I
I
II
CONSTRUCTION PROJECT BY PATIENT RISK
IC MATRIX - CLASS OF PRECAUTIONS:
INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK
NOTE:
LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
INSPECTION AND NON-INVASIVE ACTIVITIES
TYPE A
SMALL SCALE, SHORT DURATION ACTIVITIES
TYPE B
WHICH CREATES MINIMAL DUST.
WORK THAT GENERATES A MODERATE TO
TYPE C
HIGH LEVEL OF DUST OR REQUIRES DEMOLITION
OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES
MAJOR DEMOLITION AND CONSTRUCTION
TYPE D
PROJECTS
MATRIX OF PRECAUTIONS FOR
CONSTRUCTION & RENOVATION
I R AC (ICRA)
ANTE ROOM
ELEVATION
AREA UNDER
FRAMED
PICTURE
OF
C.O.R.
ICRA, ILSM
FIRE WATCH
MISC. FORMS
PAPER
CADDY
CONSTRUCTION
RESTRICTED AREA
THIS IS A
CONST. SUPERVISOR
NAME AND
CELL PHONE
XXXXXX XXXX XXXX
CHILLER PLANT AFTER HOURS
CONTACT PHONE 53230
FIRE EMERGENCY DIAL 4911
XXXXXX XXXX XXXX
XXXXXX XXXX XXXX
WITH CONTACT
INFORMATION
C
LA
SS
V
1. ISOLATE H.V.A.C. SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS IE. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL
AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH
PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR
VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS IF INDICATED.
4. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY.
5. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM
7. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL.
8. ROOM AND/OR SHALL BE THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL
SERVICES DEPARTMENT.
2. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
5. VACUUM WORK AREA WITH HEPA FILTERED VACUUM.
6. WET MOP AREA WITH DISINFECTANT.
SO THEY CAN BE VACUUMED USING HEPA VACUUM CLEANER BEFORE LEAVING WORK
SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH
TIME THEY LEAVE THE WORK SITE.
6. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS.
SHOE COVERS MUST BE CHANGED EACH TIME THE WORKER EXITS THE WORK AREA.
SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH
TIME THEY LEAVE THE WORK SITE.
3. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
7. REMOVE ISOLATION OF H.V.A.C. SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
4. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
PRIOR TO ANY CONSTRUCTION
POST CONSTRUCTION
1. OBTAIN APPROVAL BY MCOT TEAM TO REMOVE BARRIERS.
TYPICAL IDEAL
CONSTRUCTION LAYOUT
CLASS IV
ELEVATION
TYPE B
TYPE A
CROSS-SECTION 'A-A' MOBILE CONTAINMENT CART
CLASS IV
INTERIM LIFE SAFETY MEASURES:
INFECTION CONTROL RISK ASSESSMENT:
PICRA:
UTILITIES SHUT-DOWNS:
ICRA
ILSM
4-GJ-509
3 12
TYPE IV ICRA CONSTRUCTION
DETAILS
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
1069REDEH
2' X 4' SUSPENDED
WALL CONST. TYPES (DETAILS)
TYPE A
BASE @ BOTH SIDES
4" RUBBER COVE
W A
LL
H
EI
G H T
V
ER
IE
S
TYPE B
C
EI
LI
N G
H
EI
G H T
'-0
ON FLOOR PLAN.
FI
EL
D V
ER
IF
Y
C
EI
LI
N G
H
EI
G H T
'-0
4 7/8"4 7/8" W
A
LL
H
EI
G H T
V
ER
IE
S
FI
EL
D V
ER
IF
Y
TO MATCH EXISTING AREA
ROOF METAL DECKING
AS SCHEDULED
ACOUSTICAL CEILING
2' X 4' SUSPENDED
ON FLOOR PLAN.
HARD WALL ICRA
BARRIERS ARE
REQUIRED FOR ICRA
AND SHALL HAVE A 1
HR FIRE RATING AND
SOUND ATTENUATION.
BASIS OF DESIGN:
STARC SYSTEMS FIRE
BLOCK WALL. WALL TO
EXTEND TO ROOF METAL
DECKING
4" RUBBER COVE TO
MATCH EXISTING AREA
BASE @ BOTH SIDES
HARD WALL ICRA
BARRIERS ARE
REQUIRED FOR ICRA
AND SHALL HAVE A 1
HR FIRE RATING AND
SOUND ATTENUATION.
BASIS OF DESIGN:
STARC SYSTEMS FIRE
BLOCK WALL. WALL TO
EXTEND TO ROOF METAL
DECKING
GENERAL NOTES:
LOW RISK
OFFICE AREAS
PATIENT RISK GROUPS
MEDIUM RISK HIGH RISK HIGHEST RISK
CARDIOLOGY CCU ANY AREA CARING FOR
ECHOCARDIOGRAPHY
ENDOSCOPY
NUCLEAR MEDICINE
PHYSICAL THERAPY
RADIOLOGY/MRI
RESPIRATORY THERAPY
EMERGENCY ROOM
LABOR & DELIVERY
LABORATORY (SPECIMEN)
NEWBORN NURSERY
OUTPATIENT SURGERY
PEDIATRICS
IMMUNOCOMPROMISED PATIENTS
BURN UNIT
CARDIAC CATH LAB
CENTRAL STERILE SUPPLY
INTENSIVE CARE UNITS
MEDICAL UNIT
PHARMACY
POST ANESTHESIA CARE UNIT
SURGICAL UNITS
NEGATIVE PRESSURE ISOLATION ROOMS
ONCOLOGY
OPERATING ROOMS INCLUDING
C-SECTION ROOMS
LOW RISK GROUP
CONSTRUCTION PROJECT TYPE
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP
RISK RELATED GROUP TYPE A TYPE B TYPE C TYPE D
I II II III/IV
II
II III/IV
III/IV
III
III/IV
IV
IV
IV
I
I
II
CONSTRUCTION PROJECT BY PATIENT RISK
IC MATRIX - CLASS OF PRECAUTIONS:
INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK
NOTE:
LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
INSPECTION AND NON-INVASIVE ACTIVITIES
TYPE A
SMALL SCALE, SHORT DURATION ACTIVITIES
TYPE B
WHICH CREATES MINIMAL DUST.
WORK THAT GENERATES A MODERATE TO
TYPE C
HIGH LEVEL OF DUST OR REQUIRES DEMOLITION
OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES
MAJOR DEMOLITION AND CONSTRUCTION
TYPE D
PROJECTS
MATRIX OF PRECAUTIONS FOR
CONSTRUCTION & RENOVATION
I R AC (ICRA)
ANTE ROOM
ELEVATION
AREA UNDER
FRAMED
PICTURE
OF
C.O.R.
ICRA, ILSM
FIRE WATCH
MISC. FORMS
PAPER
CADDY
CONSTRUCTION
RESTRICTED AREA
THIS IS A
CONST. SUPERVISOR
NAME AND
CELL PHONE
XXXXXX XXXX XXXX
CHILLER PLANT AFTER HOURS
CONTACT PHONE 53230
FIRE EMERGENCY DIAL 4911
XXXXXX XXXX XXXX
XXXXXX XXXX XXXX
WITH CONTACT
INFORMATION
C
LA
SS
V
1. ISOLATE H.V.A.C. SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS IE. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL
AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH
PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR
VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS IF INDICATED.
4. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY.
5. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM
7. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL.
8. ROOM AND/OR SHALL BE THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL
SERVICES DEPARTMENT.
2. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
5. VACUUM WORK AREA WITH HEPA FILTERED VACUUM.
6. WET MOP AREA WITH DISINFECTANT.
SO THEY CAN BE VACUUMED USING HEPA VACUUM CLEANER BEFORE LEAVING WORK
SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH
TIME THEY LEAVE THE WORK SITE.
6. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS.
SHOE COVERS MUST BE CHANGED EACH TIME THE WORKER EXITS THE WORK AREA.
SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH
TIME THEY LEAVE THE WORK SITE.
3. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
7. REMOVE ISOLATION OF H.V.A.C. SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
4. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
PRIOR TO ANY CONSTRUCTION
POST CONSTRUCTION
1. OBTAIN APPROVAL BY MCOT TEAM TO REMOVE BARRIERS.
TYPICAL ALTERNATIVE
CONSTRUCTION LAYOUT
CLASS IV
CROSS-SECTION 'A-A' MOBILE CONTAINMENT CART
C O
R R
ID
O
R
H A
LL
W
A Y
CLASS IV (CONST. BARRIER TYPES)
INTERIM LIFE SAFETY MEASURES:
INFECTION CONTROL RISK ASSESSMENT:
PICRA:
UTILITIES SHUT-DOWNS:
ICRA
ILSM
4-GJ-5010
3 12
TYPE IV ICRA CONSTRUCTION
ALTERNATE DETAILS
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
05-15-2024
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
10610REDEH
1-AE-001
SYMBOLS AND ABBREVIATIONS
MJBMFC 11
ELEVATION INDICATOR
BREAK, ROUND (USER DEFINES SIZE)
BREAK, STRAIGHT (SEE SECTION INDICATORS,
BUILDING, WITH BREAK STANDARDS)
DETAIL INDICATOR
DIMENSION LINE
DOOR OPENING
DRAWING BLOCK TITLE, TYPICAL
ELEVATION INDICATOR, INTERIOR, MULTIPLE VIEW
ELEVATION INDICATOR, INTERIOR, SINGLE VIEW
CENTER LINE
DRAWING BLOCK TITLE
1 1/2" = 1'-0"
ROOM NAME AND NUMBER
KEYNOTE
NORTH ARROW
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NEW CONSTRUCTION
CONCRETE
EARTH
EQUAL DIMENSIONS ON BOTH SIDES
CRUSHED STONE
NOTE
X
XXX
ROOM NAME
XXX
XXX
NOTE
DOOR TAG
WINDOW TAG
DRAWING SCALE
MATERIAL LEGEND
BUILDING LEGEND
ARCHITECTURAL SYMBOLS
@ AT
A/C AIR CONDITIONING
ABAAS ARCHITECTURAL
BARRIERS ACT
ACCESSIBILITY
GUIDELINES
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT-SEE
A.B.A.A.S.
ADJ ADJACENT, ADJUSTABLE
ADMIN ADMINISTRATION
AFF ABOVE FINISH FLOOR
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATIVE
ALUM ALUMINUM
APP'D APPROVED
ARCH ARCHITECTURAL
AUTO AUTOMATIC
AVG AVERAGE
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BOTT BOTTOM
CAB CABINET
CHK'D CHECKED
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CO CONTRACTING OFFICER
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CPT, CRPT CARPET
CTR CENTER
CW COLD WATER
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA, Ø DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR, ELEVATION
EOB END OF BUSINESS
EPDM ETHYLENE PROPYLENE
DIENE MONOMER (ROOF
MEMBRANE)
EQ = EQUAL
EQPM EQUIPMENT
EX, EXST EXISTING
FAX FACSIMILE
FD FLOOR DRAIN
FDN, FDTN FOUNDATION
FE FIRE EXTINGUISHER
FIN FINISH
FLR FLOOR
FT (') F00T OR FEET
FTG FOOTING
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
GMU GLAZED MASONRY UNIT
GYP GYPSUM
HB HOSE BIBB
HDW HARDWARE
HT, HGT HEIGHT
HM HOLLOW METAL
HORZ HORIZONTAL
HVAC HEATING VENTILATION
AND AIR CONDITIONING
HW HOT WATER
ID INSIDE DIAMETER
IN (") INCH OR INCHES
INSUL INSULATION
INT INTERIOR
JAN JANITOR
KO KNOCK OUT
LAV LAVATORY
LCD LIQUID CRYSTAL DISPLAY
LB POUND
LH LEFT HAND
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MH MAN HOLE
MIN MINIMUM
MISC MISCELLANEOUS
MRR MEN'S RESTROOM
MULT MULTIPLE
N/A NOT APPLICABLE
NCA VA NATIONAL CEMETERY
ADMINISTRATION
NIC NOT IN CONTRACT
NO, # NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPP OPPOSITE
OPNG OPENING
PEMB PRE-ENGINEERED METAL
BUILDING
PH PHASE
P LAM PLASTIC LAMINATE
PLUM PLUMBING
PR PAIR
PRG POLYMER RUBBER GEL
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PTR PRINTER
PROC PROCESSING
QTY QUANTITY
R RADIUS
RD ROOF DRAIN
REC RECEPTION
REQ, REQD REQUIRED
REV REVISE, REVISION
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RR RESTROOM
SECT SECTION
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STRG, STOR STORAGE
T TEMPERED
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
TEL TELEPHONE
TELCOM TELECOMMUNICATIONS
TEMP TEMPORARY
THK THICK, THICKNESS
THRU THROUGH
TYP TYPICAL
UL UNDERWRITERS
LABORATORIES
UNO UNLESS NOTED
OTHERWISE
VA VETERANS
ADMINISTRATION
VCT VINYL COMPOSITE TILE
VERT VERTICAL
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WIN, WDW WINDOW
WT WEIGHT
WRR WOMEN'S RESTROOM
GENERAL ABBREVIATIONS:
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
M
IC
HAEL F . CONLY
RE
GISTERED
STATE OF
No.
AR00032507R
E
ARCH I T
EG
I STERED
C T
I N D I A NA
05-15-2024
KEY PLAN
UP
A2-S1 B231
A234 A234A
A202EA203E
B204B205B206
B232
B230
B225F
B2-C1
B225
B225A
B223
B222
B221E
B215E
B2-C3
B213
B214
B215
B216AB217B218
B226A
B226
B209B208
B207
A203
B232A
B233
B229A
B229
B227A
B227 B228
B2-S3
B218A
B219
B220A
B220
B221
B216 A202
B210B212
B2 -C
B2 -C
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
D1
E
F
G
H
J
4-AD-122
FLOOR PLAN DEMO. SECOND
FLOOR - B WING
MJBMFC 12
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
M
IC
HAEL F . CONLY
RE
GISTERED
STATE OF
No.
AR00032507R
E
ARCH I T
EG
I STERED
C T
I N D I A NA
NO ANTICIPATED FLOOR WORK
LEGEND:
DEMO KEY NOTE:
1. CONSTRUCT DUST BARRIER AS MARKED ON DRAWINGS. DO NOT
BLOCK WAYS OF EGRESS.
2. DEMO DRINKING FOUNTAIN. TERMINATE ALL ASSOCIATED WATER
SUPPLY AND DRAINS. PER ALL PERTAINING PLUMBING CODES AND
PRACTICES.
3. DEMO WALL COMPLETELY AS SHOWN, FULL HEIGHT. WHERE
DEMO TERMINATES , TAKE CARE NOT TO DAMAGE WALL TO
REMAIN. REPAIR DAMAGES AFTER NEW WALL CONSTRUCTION.
X
1 2 3
A
B
E
C
D1
D
F
G
H
J
10 16 17 18 19 20 21 22 23 24 251211 13 14 15
A201
A236
A271
A234F
A238
A269 C268 C267
C265
C239A
C240
C239
C249
C250
C256 C255A
C254
C253A
C253
C263 C255
C262
C256E
C251E
C257
C258
C2-S2
C247
C243A
C243
C242
C246A
C246
C2
F
C247G
C244A
C264
C2-C1
C2 -C
C252
C241 C251AC251
C244
C247A
A270
C266
C261
C2 -C
C259
A2-9
ROOF BELOW
ROOF BELOW
ROOF BELOW
ROOF BELOW
A0-E10
4-AD-123
FLOOR PLAN DEMO SECOND
FLOOR - A-C WING
MJBMFC 13
NO ANTICIPATED FLOOR WORK
LEGEND:
DEMO KEY NOTE:
1. CONSTRUCT DUST BARRIER AS MARKED ON DRAWINGS. DO NOT
BLOCK WAYS OF EGRESS.
2. DEMO DRINKING FOUNTAIN. TERMINATE ALL ASSOCIATED WATER
SUPPLY AND DRAINS. PER ALL PERTAINING PLUMBING CODES AND
PRACTICES.
3. DEMO WALL COMPLETELY AS SHOWN, FULL HEIGHT. WHERE
DEMO TERMINATES , TAKE CARE NOT TO DAMAGE WALL TO
REMAIN. REPAIR DAMAGES AFTER NEW WALL CONSTRUCTION.
X
1 2 3 www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
M
IC
HAEL F . CONLY
RE
GISTERED
STATE OF
No.
AR00032507R
E
ARCH I T
EG
I STERED
C T
I N D I A NA
UP
E
D1
D
F
G
H
9 10 1211
B0-C1
B09B09A
B09B A0-S1
A11
A2E A01E
B06
B07E
B08F
B08
B07 A01
AREA B2
AREA B1
CRAWL SPACE
OPEN TO BELOW
SEE SHT. AE202
B05 B04 B03 A02
KEY PLAN
87654321
DN
B0-C1 A11
A2E A01EB07E
B08F
B08
DN
B0-C1 A11
A2E A01EB07E
B08F
B08
4-AC-1B4
REFLECTED CEILING PLAN
BASEMENT FLOOR - B WING
MJBMFC 14
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration
CONSTRUCTION DOCUMENTS
DESIGN REPLACE HVAC &
ASSOCIATED COMPONENTS
589A5-22-106
COLMERY-O'NEIL VAMC
2200 SW GAGE BLVD. - TOPEKA, KS 66622
FULLY SPRINKLERED
ARCHITURA CORPORATION
9880 Westpoint Drive, Suite #400 Indianapolis, IN 46256-3384
PH: (317) 348-1000
POC: Michael Conly, AIA, NCARB, President
M
IC
HAEL F . CONLY
RE
GISTERED
STATE OF
No.
AR00032507R
E
ARCH I T
EG
I STERED
C T
I N D I A NA
SEE MECHANICAL
SEE MECHANICAL
SEE MECHANICAL
NO WORK ANTICIPATED
CEILING WORK NOT IN CONTRACT
LEGEND:
AREA OF CEILING WORK IN
CONTRACT
DEMO KEY NOTE:
1. REMOVE SECTIONS OF CEILING PANELS AND CROSS TEES TO
ALLOW ADEQUATE ROOM FOR DEMO OF EXISTING DUCT. TAKE
CARE NOT TO DAMAGE WI-FI BOOSTERS, EXIT SIGNS, INTERCOM
SPEAKERS, AND SENSORS ENTIRE LENGTH OF HALLS: B0-C1,
A0-C1, AND C0-C1. SEE MECHANICAL PLANS AND DRAWINGS FOR
EXTENT OF DUCT WORK.
2. REMOVE EXISTING DUCTWORK PENETRATING FIREWALL,
EXISTING FIREWALL TO REMAIN, SEE MECHANICAL DRAWINGS
AND PLANS.
CONSTRUCTION KEY NOTE:
1. CLEAN AND PAINT DISCOLORED OR SCRATCHED CROSS TEES.
INSTALL CROSS TEES REPLACING DAMAGED SECTIONS WITH NEW
TO MATCH EXISTING. SUPMIT SAMPLES TO VA-COR AND BUILDING
MANAGER FOR APPROVAL.
2. INSTALL CEILING PANELS (REPLACE WITH NEW PANELS
EVERYWHERE.) SAVE REUSABLE EXISTING PANELS FOR "ATTIC
STOCK". MATCH EXISTHING IN SIZE (2' X 2') IN CORRIDORS B0-C1,
A0-C1, C0-C1. SUBMIT SAMPLE TO VA-COR FOR REVIEW. SEE
MECHANICAL FOR EXTENT OF WORK.
3. INSTALL DUCTWORK THROUGH FIREWALL PER MECHANICAL
PLANS AND DRAWINGS. IF PENETRATION IS LARGER OR SMALLER
THAN EXISTING PENETRATION REFER TO MECHANICAL. CONFIRM
FIRE CAULK AND FIRE RATED DUCT COLLAR ARE USED AT
PENETRATION.
X
2 11
4-AC-1B4
A2/A3
1 1
C0-C1A0-C1
C17 C17A
C17B
C17F
C18
C19E
C15
C15B
C15A
C19
C23 C22 A24
A24A
A24B
A13
A1 2F
A01A
A01
C21 C20
A0-E9
CRAWL SPACE
TO MECHANICAL
ACCESS PIT,
OPEN TO EXTERIOR
A14
A0-E10
KEY PLAN
16 17 18 19 20 21 22 23 2412 13 14 15
16 17 18 19 20 21 22 23 2412 13 14 15
UP
C0-C1A0-C1
C17 C17A
C17B
C17F
C18
C19E
C15
C15B
C15A
C19
C23 C22 A24
A24A
A24B
A13
A1 2F
A01A
A01
C21 C20
A0-E9
CRAWL SPACE
TO MECHANICAL
ACCESS PIT,
OPEN TO EXTERIOR
A14
A0-E10
4-AC-1B5
REFLECTED CEILING PLAN
BASEMENT FLOOR - A-C WING
MJBMFC 15
www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions:…