02 Renovate Behavioral Health Addendum _1 Drawings 7.16.21 UPDATED.pdf

PDF 5 MB Posted

Attached to
Z2DA-- Renovate Behavioral Health Clinic P/N:589A4-19-103
Solicitation number
36C25521R0089
Issued by

About this file

This notice announces a solicitation for renovation services. The Department of Veterans Affairs intends to solicit proposals to renovate approximately 14,795 square feet of space at the Harry S. Truman Memorial Veterans Hospital in Columbia, Missouri to consolidate behavioral health clinics. Renovations will include new electrical, HVAC, plumbing, fire protection, data/voice systems, and interior finishes. Work will be conducted in multiple phases to minimize disruptions to patient care. The estimated value is between $2-5 million. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses and utilize the Lowest Price Technically Acceptable source selection process. The North American Industry Classification Code is 236220. Proposals will be due in July 2021 with an anticipated 800-day period of performance. Interested offerors should monitor the beta SAM website for solicitation details.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING LIST

VICINITY MAP

PROJECT TEAMBUILDING SUMMARYGENERAL NOTES

1. THESE DRAWINGS SHALL BE USED ONLY FOR THIS SPECIFIC PROJECT/SITE

LOCATION. THESE DRAWINGS ARE A COMPOSITE SET OF CONTRACT

DOCUMENTS AND SHALL NOT BE SEPARATED FOR DISTRIBUTION. THE GENERAL

CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW ALL DRAWINGS AND

SPECIFICATIONS.

2. IT IS HIGHLY RECOMMENDED THAT THE GENERAL CONTRACTOR ATTEND THE

PRE-BID MEETING TO INSPECT EXISTING CONDITIONS AND VERIFY WORK BEING

PERFORMED BEFORE SUBMITTING COST QUOTATIONS FOR WORK.

3. NOTIFY THE COTR PROMPTLY OF ANY ERRORS, OMISSIONS,

INCONSISTENCIES, DISCREPANCIES AND CONFLICTS WITHIN THE CONTRACT

DOCUMENTS AND ITS ASSOCIATED FIELD/PROJECT CONDITIONS SO THAT A

RESOLUTION CAN BE PROVIDED PRIOR TO CONTINUING WITH WORK.

4. DO NOT SCALE THE DRAWINGS. REQUEST ANY MISSING DIMENSIONS FROM

THE ARCHITECT.

5. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH GOVERNING

FEDERAL, STATE AND LOCAL BUILDING CODE REQUIREMENTS, SHALL BE

EXECUTED IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS, AND

SHALL CONFORM TO SPECIFIC REGULATIONS AS MANDATED BY THE OWNER,

THE ARCHITECT, AND THE AUTHORITIES HAVING JURISDICTION. THE GENERAL

CONTRACTOR IS RESPONSIBLE FOR ANY FEES ASSOCIATED WITH PROCURING

SUCH PERMITS AND CERTIFICATES AND SHALL FURNISH COPIES OF PERMITS,

INSPECTIONS, AND CERTIFICATES TO THE OWNER.

6. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK TO MINIMIZE

DISRUPTION OF ANY EXISTING TENANTS OR BUILDING OPERATIONS. THE

GENERAL CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO PROTECT

BUILDING OCCUPANTS, MATERIALS, AND EXISTING CONSTRUCTION

THROUGHOUT ALL PHASES OF CONSTRUCTION. DAMAGE TO EXISTING-TO-

REMAIN CONSTRUCTION OR EQUIPMENT SHALL BE RESTORED TO ORIGINAL

CONDITION AT THE CONTRACTOR'S EXPENSE.

7. THE GENERAL CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM

THE JOB SITE ON A DAILY BASIS.

8. ANY REQUESTS FOR SUBSTITUTIONS OF ANY SPECIFIED ITEM ARE TO BE

SUBMITTED TO THE COTR AND ARCHITECT IN WRITING AND WILL BE

CONSIDERED ONLY IF THE ALTERNATE PROPOSED IS PROVEN TO BE

ADVANTAGEOUS TO THE OWNER WITH RESPECT TO DELIVERY DATE, QUALITY,

AND/OR COST. SUBSTITUTION REQUESTS MUST BE MADE PRIOR TO BID.

9. THE MEANS AND METHODS OF CONSTRUCTION, TEMPORARY STRUCTURES

AND FACILITIES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE

ARCHITECT DOES NOT ASSUME ANY RESPONSIBILITY FOR THE CONTRACTOR'S

MEANS AND METHODS, TEMPORARY STRUCTURES OR FACILITIES.

10. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DEMOLISHING AND

REMOVING EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW

CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE

THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS.

11. JOB SITE SAFETY AND SECURITY ARE THE SOLE RESPONSIBILITY OF THE

GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE

FOR MEETING OSHA & NFPA REGULATIONS DURING CONSTRUCTION.

12. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR STORAGE AND

PROTECTION OF BUILDING MATERIALS, AND INSTALLED CONSTRUCTION, FROM

INCLEMENT WEATHER, THEFT, AND OTHER HAZARDS. THE GENERAL

CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS FOR

STORAGE OF MATERIALS. PARTIALLY COMPLETED WALLS SHALL BE COVERED

TO PROTECT FROM WATER INTRUSION. DAMAGE, INCLUDING BUT NOT LIMITED

TO MOLD, RESULTING FROM WATER INTRUSION DURING CONSTRUCTION SHALL

BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE.

PROJECT INFORMATION

PROJECT NAME: RENOVATE BEHAVIORAL HEALTH CLINIC

PROJECT NUMBER: 589A4-19-103

PROJECT LOCATION: 800 HOSPITAL DRIVE, COLUMBIA, MO 65201

PROJECT PURPOSE/USE: PHASE 1:THE PROJECT WILL RENOVATE APPROXIMATELY 5,089 SQUARE FOOT ON THE FOURTH FLOOR OF VA TRUMAN MEMORIAL VETERANS BUILDING IN COLUMBIA, MISSOURI.

THIS WILL INCLUDE PROCEDURE ROOMS, PAIN EXAM ROOMS, PM&R EXAM ROOMS, NURSE WORK

ROOMS, MSA CHECKIN, SWAMP ROOMS, EMG/SCI ROOM, PAIN BH, AND PAIN PHARM ROOMS.

PHASE 2-4: THE PROJECT WILL RENOVATE APPROXIMATELY 9,706 SQUARE FOOT OF STATE-OF-THE-ART

OUT-PATIENT BEHAVIORAL HEALTH CLINIC LOCATED ON THE SECOND FLOOR OF VA TRUMAN

MEMORIAL VETERANS BUILDING IN COLUMBIA, MISSOURI. THIS WILL INCLUDE GROUP ROOMS,

ADMINISTRATIVE OFFICES, CLINICAL OFFICES WHICH DOUBLE AS COUNSELING ROOMS, PUBLIC

RESTROOMS, A CENTRAL CHECK-IN/WAITING ROOM AND A STAFF BREAK ROOM.

VA LEADERSHIP SIGNATURES

0' 1'

6" 3"

1'

Gr ap hi c S ca le

: 1 /2"

1'-

0"

0' 4"

8" 1'

2'

Gr ap hi c S ca le

: 3 /32

1'

-0

0'

8' Gr ap hi c S ca le : 1

/16

1' -0

0' 8'

4' Gr ap hi c S ca le

: 1 /8"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 1 /4"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 3 /8"

1'-

0"

0' 2'

4' 1' Gr ap hi c S ca le : 1

/2"

1'- 0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 3 /4"

1'-

0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 1

1' -0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

A/E:Consultant:

EE

ES

S OF

M

R C

D

T

T T

IIN

U A

AA

V

RAP

M

N

T

T OF

E E

D

RS

I

FA

A

NT

SR

F

AEE

Fully Sprinklered

BI

M

VI

SN

- B eh av io ra l H ea lth C lin ic

R en ov at io n/

BH

C lin ic

R en ov at io n.

rv t

7/

/2

:2 3:

P

M

SHEET INDEX & GENERAL INFORMATION

RCO EM

Columbia, Missouri

5/13/2021 (ADDENDUM

#1 - 7.16.21)

STATION: Columbia, Missouri

BUILDING NUMBER: 1

1-GI100

589A4-19-103

Columbia Harry S. Truman Memorial Veterans Hospital

BID DOCUMENTS Columbia Harry S. Truman Memorial Veterans Hospital

BID DOCUMENTS

5/13/2021 (ADDENDUM #1 - 7.16.21)

PROJECT LOCATION: 800 HOSPITAL DRIVE, COLUMBIA, MO

65201

SHEET

NUMBER SHEET TITLE

1-MD201 LEVEL 02- VENTILATION DEMOLITION

1-MD202 LEVEL 03 - VENTILATION DEMOLITION

1-MD203 LEVEL 04 - VENTILATION DEMOLITION

1-MH101 LEVEL 02 - VENTILATION

1-MH102 LEVEL 03 - VENTILATION

1-MH103 LEVEL 04 - VENTILATION

1-MH300 VENTILATION DETAILS

1-MH400 VENTILATION DIAGRAMS

1-MH500 VENTILATION SCHEDULES

1-MH501 VENTILATION SCHEDULES

1-E-000 ELECTRICAL COVER SHEET

1-ED101 LEVEL 02 - ELECTRICAL DEMOLITION

1-ED102 LEVEL 04 - ELECTRICAL DEMOLITION

1-E101 LEVEL 03 - ELECTRICAL

1-EL101 LEVEL 02 - ELECTRICAL LIGHTING

1-EL103 LEVEL 04 - ELECTRICAL LIGHTING

1-EP101 LEVEL 02 - ELECTRICAL POWER

1-EP102 LEVEL 04 - ELECTRICAL POWER

1-FA101 LEVEL 02 - FIRE ALARM

1-FA102 LEVEL 04 - FIRE ALARM

1-E-300 ELECTRICAL DETAILS

1-E-500 ELECTRICAL SCHEDULES

1-E-501 ELECTRICAL SCHEDULES

1-ET-000 TELECOMMUNICATIONS COVERSHEET

1-TD101 LEVEL 02 - TELECOMMUNICATIONS DEMOLITION

1-TD102 LEVEL 04 -TELECOMMUNICATIONS DEMOLITION

1-ET101 LEVEL 01 - TELECOMMUNICATIONS

1-ET102 LEVEL 02 - TELECOMMUNICATIONS

1-ET103 LEVEL 03 - TELECOMMUNICATIONS

1-ET104 LEVEL 04 - TELECOMMUNICATIONS

1-ET201 ENLARGED PLANS - TELECOMMUNICATIONS

1-T-300 TELECOMMUNICATIONS DETAILS

1-T-400 TELECOMMUNICATIONS DIAGRAMS

1-T-500 TELECOMMUNICATIONS SCHEDULES

SHEET

NUMBER SHEET TITLE

1-AE706 CEILING DETAILS SUSPENDED GYPSUM

1-AE707 SECOND FLOOR WINDOW, DOOR & STAIR DETAILS

1-AF101 SECOND FLOOR DOOR & WINDOW SCHEDULES

1-AF102 FOURTH FLOOR DOOR SCHEDULE & DETAILS

1-AF103 SECOND FLOOR FINISH PLAN & SCHEDULES

1-AF104 FOURTH FLOOR FINISH PLAN & SCHEDULES

1-AF105 SECOND FLOOR WALL TYPES

1-AF106 FOURTH FLOOR WALL TYPES

1-AW101 SECOND AND FOURTH FLOOR SIGNAGE PLAN

1-AW102 SIGNAGE PLAN DETAILS

1-AW103 SIGNAGE PLAN DETAILS

1-FX000 FIRE PROTECTION COVERSHEET

1-FD101 LEVEL 02 - FIRE PROTECTION DEMOLITION

1- FD102 LEVEL 04 - FIRE PROTECTION DEMOLITION

1-FX101 LEVEL 02 - FIRE PROTECTION

1- FX102 LEVEL 04 - FIRE PROTECTION

1-P-000 PLUMBING COVER SHEET

1-PD100 PIPE BASEMENT - PLUMBING DEMOLITION

1-PD101 LEVEL 01 - PLUMBING DEMOLITION

1-PD102 LEVEL 02 - PLUMBING DEMOLITION

1- PD103 LEVEL 03 - PLUMBING DEMOLITION

1- PD104 LEVEL 04 - PLUMBING DEMOLITION

1-PL100 BASEMENT-PLUMBING

1-PL101 LEVEL 01 - PLUMBING

1-PL102 LEVEL 02 - PLUMBING

1- PL103 LEVEL 03 - PLUMBING

1- PL104 LEVEL 04 - PLUMBING

1- P-300 PLUMBING DETAILS

1- P-400 PLUMBING RISERS

1- P-401 PLUMBING RESTROOM RISER

1-MP000 PIPING COVERSHEET

1-MD101 LEVEL 02 - MECHANICAL PIPING DEMOLITION

1-MD102 LEVEL 03 - MECHANICAL PIPING DEMOLITION

1-MD103 LEVEL 04 - MECHANICAL PIPING DEMOLITION

1-MP101 LEVEL 02 - MECHANICAL PIPING

1-MP102 LEVEL 03 - MECHANICAL PIPING

1-MP103 LEVEL 04 - MECHANICAL PIPING

1-MP300 MECHANICAL PIPING DETAILS

1-MP400 MECHANICAL PIPING DIAGRAMS

1-MH000 VENTILATION COVERSHEET

SHEET

NUMBER SHEET TITLE

1-GI100 SHEET INDEX & GENERAL INFORMATION

1-GI101 BUILDING CODE

1-GI102 ABBREVIATIONS & SYMBOLS

1-GI103 SECOND FLOOR LIFE SAFETY PLAN

1-GI104 FOURTH FLOOR LIFE SAFETY PLAN

1-GC101 SECOND & FOURTH FLOOR PHASING & INTERIM LIFE SAFETY PLANS

1-GC102 THIRD FLOOR PHASING PLAN

1-AD101 FIRST FLOOR RCP DEMOLITION PLAN & REFLECTED CEILING PLAN

1-AD102 SECOND FLOOR RCP DEMOLITION PLAN

1-AD103 SECOND FLOOR DEMOLITION PLAN

1-AD104 THIRD FLOOR RCP DEMOLITION PLAN & REFLECTED CEILING PLAN

1-AD105 FOURTH FLOOR RCP DEMOLITION PLAN

1-AD106 FOURTH FLOOR DEMOLITION PLAN

1-AE101 OVERALL SECOND FLOOR PLAN

1-AE102 ENLARGED SECOND FLOOR PLAN

1-AE103 OVERALL FOURTH FLOOR PLAN

1-AE104 ENLARGED FOURTH FLOOR PLAN

1-AE105 SECOND FLOOR DIMENSION PLAN

1-AE106 FOURTH FLOOR DIMENSION PLAN

1-AE107 SECOND FLOOR REFLECTED CEILING PLAN

1-AE108 FOURTH FLOOR REFLECTED CEILING PLAN

1-AE109A SECOND FLOOR EQUIPMENT PLAN

1-AE109B ENLARGED SECOND FLOOR TMS ROOM EQUIPMENT PLAN &

ELEVATIONS

1-AE110A FOURTH FLOOR EQUIPMENT PLAN

1-AE110B FOURTH FLOOR EQUIPMENT PLAN INTERIOR ELEVATIONS

1-AE110C FOURTH FLOOR EQUIPMENT PLAN INTERIOR ELEVATIONS

1-AE110D FOURTH FLOOR EQUIPMENT PLAN INTERIOR ELEVATIONS

1-AE110E FOURTH FLOOR EQUIPMENT PLAN INTERIOR ELEVATIONS

1-AE110F FOURTH FLOOR EQUIPMENT PLAN INTERIOR ELEVATIONS

1-AE401 SECOND FLOOR ENLARGED TOILET PLANS AND ELEVATIONS

1-AE402 SECOND FLOOR ENLARGED TOILET PLANS AND ELEVATIONS

1-AE403 FOURTH FLOOR ENLARGED TOILET PLANS AND ELEVATIONS

1-AE501 SECOND FLOOR MILLWORK PLAN & ELEVATIONS

1-AE502 FOURTH FLOOR MILLWORK PLAN & ELEVATIONS

1-AE503 SECOND FLOOR MILLWORK SECTIONS

1-AE504 FOURTH FLOOR MILLWORK ELEVATIONS & SECTIONS

1-AE702 MISCELLANEOUS DETAILS

1-AE703 SECOND FLOOR CEILING DETAILS

1-AE704 FOURTH FLOOR CEILING DETAILS

1-AE705 METAL STUD DETAILS

ARCHITECT:

Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX

Rebecca Olson, AIA, ACHA Rebecca.olson@romanykconsulting.com

855-424-3838 ext.302 602-430-1265 cell

MECHANICAL ENGINEER:

IMEG

15 Sunnen Drive Suite 104 St. Lois, MO

Scott Przybysz Scott.R.Przybysz@imegcorp.com

314-951-2535

ELECTRICAL ENGINEER:

IMEG

15 Sunnen Drive Suite 104 St. Louis, MO

Mark T. Harris marc.t.harris@imegcorp.com

314-951-2509 314-249-8634

PLUMBING ENGINEER:

IMEG

15 Sunnen Drive Suite 104 St.Louis, MO

Scott Przybysz Scott.R.Przybysz@imegcorp.com

314-951-2535

OWNER:

Department of Veteran Affairs Harry S. Truman Memorial Veterans' Hospital 800 Hospital Drive, Columbia, MO 65201

Jeanette Mathena Jeanette.Mathena@va.gov

Jason Bavlnka jason.bavlnka@va.gov

TECHNOLOGY:

IMEG

15 Sunnen Drive Suite 104 St.Louis, MO

Scott Thomas scott.b.thomas@imegcorp.com

FIRE PROTECTION:

IMEG

15 Sunnen Drive Suite 104 St.Louis, MO

Scott Przybysz Scott.R.Przybysz@imegcorp.com

314-951-2535

INTERIOR DESIGN:

OCULUS INC.

1 South Memorial Drive Suite 1500 St.Louis, MO

Carolyn Fava carolynf@oculusinc.com

314-450-5368

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

PROJECT NAME: RENOVATE BEHAVIORAL HEALTH CLINIC

PROJECT NUMBER: 589A4-19-103

Revisions: Date:

Addendum #1 7.16.21

FDFD

FD

FD

FEC

FE

C

FE

C

FEC

FEC

FEC

FE

C

FEC

FE

C

AREA PLAN LEGEND

GENERAL NOTES:KEY NOTES

BARRIER LEGEND

P Na N M L

2.82.8

3.7 3.7

4.64.6

5.55.5

6.36.3

K J H G F

7.27.2

8.38.3

9.19.1

320 SF

A218

GROUP

ROOM

307 SF

A219

GROUP

ROOM

182 SF

A204

CLINIC

OFFICE

154 SF

A203

CLINIC

OFFICE

204 SF

A200

CLINIC

OFFICE

94 SF

A201B

OBSERVATION

197 SF

A201

PSYCH.

RES

183 SF

A206

PSYCH.

RES

24 SF

A206A

EXIST.

STRG

49 SF

A207

EXIST.

ELEC

163 SF

A210

TMS

ROOM

63 SF

A213

EXIST.

SOC

WRK

64 SF

A212

EXIST.

SOC

WRK

308 SF

A217

EXIST. IT

96 SF

A216

EXIST.

ELEC.

CLO.

185 SF

A222

MEN'S

173 SF

A221

WOMEN'S

398 SF

A223

WAITING

125 SF

A223A

CHECKOUT/CHECK

IN

372 SF

A224

WAITING

515 SF

A220

GROUP

ROOM

169 SF

A208

TMS

ROOM

MAIL AREA

A223D

72 SF

A215

HAC

111 SF

A211

CARE

COORDINATOR

112 SF

A209

CARE

COORDINATOR

64 SF

A223C

COPIER/PAPER

STORAGE

AREA

89 SF

A223B

WORK

AREA

152 SF

A202

CLINIC

OFFICE

178 SF

A205

PSYCH.

RES

1-AE501

1235 SF

A226

GROUP

ROOM

WAITING

AREA

567 SF

C2A08

CORRIDOR

861 SF

C2A07

CORRIDOR

154 SF

C2A03

CORRIDOR

143 SF

C2A05

CORRIDOR

295 SF

C2A01

CORRIDOR

63 SF

C2A02

CORRIDOR

368 SF

C2A04

CORRIDOR

1-AE402

A203

A2

B

A2

A2

A2

A2

A2

B

C 2A

A2

C 2A

A

A201

A204

A208

A209 A211

A214

A223A A223C

A224A

A218 A219

14 1414

TYPICAL ALL AREAS

1-AE401

A206A

A207

A2

A2

A2

TYP.

74 SF

STAFF RESTROOM

A214

A2

B

C2A07

A216 17

1-AE109B

65 SF

VESTIBULE

A200A

C2A04

A202

A210

27 27 27 27 2727

ROOF BELOW

BLDG.

TYP. ALL

AREAS

23 23 23

232323

24 24

TYP.

25 26

TYPICAL ALL AREAS

TYP.

TYP.

TYPICAL ALL AREAS

TYP.

TYP.

TYP. TYP.

TYP.

TYP.

203 SF

CORRIDOR 7

C2A09

28 28

TYP.

28 28

TYP.

A217

A2

B

A2

A200

A2

A

26 24

19 26 24

1-AE707

TYP.

TYP.

TYP.

TYPICAL ALL AREAS

TYPICAL ALL AREAS

TYPICAL ALL AREAS

TYPICAL

ALL AREAS

TYPICAL ALL AREAS

TYP.

TYP.

7 19

24TYP.

25 7

TYP.

26 TYP.

26 TYP.

26 TYP.

TYP.

TYP.

36 36 36 27 36 36

TYP.

TYP.

TYP. TYP. TYP. TYP. TYP. TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

AREA NOT IN CONTRACT

1. CONTRACTOR TO FIELD VERIFY EXISTING

STRUCTURAL COLUMN SPACING AND OVERALL

BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY

VA AND ARCHITECT IF ANY DISCREPANCIES ARE

FOUND BETWEEN FIELD DIMENSIONS AND

DRAWINGS.

2. G.C. SHALL VERIFY DIMENSIONS OF OWNER

FURNISHED EQUIPMENT AND COORDINATE

INSTALLATION WITH ALL TRADES WHERE

REQUIRED.

3. REFER TO FINISH SHEETS FOR PARTITION

PROTECTION INFORMATION INCLUDING BUT NOT

LIMITED TO ALL CORNER GUARD TYPES AND

LOCATIONS.

4. G.C. SHALL INSTALL IN-WALL 16 GA METAL

BACKING FOR ALL PARTITION-MOUNTED

EQUIPMENT, ACCESSORIES, PARTITION STOPS,

ETC.

5. G.C. SHALL INSTALL FIRE-RETARDANT WOOD

BLOCKING WITHIN WALLS BASED ON CASEWORK

ELEVATIONS AND ALL INTERIOR PARTITION

ELEVATIONS.

6. ALL INTERIOR WALLS SHALL RECEIVE

5/8" TYPE 'X' GYPSUM BOARD.

7. G.C. SHALL PROVIDE UL APPROVED FIRE-

RESISTIVE PENETRATION SYSTEMS AT ALL FIRE-

RATED PARTITION ASSEMBLY.

8. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED

AS NON-RATED SMOKE PARTITIONS.

9. EXTEND ALL WALLS TO UNDERSIDE OF DECK PER

UL ASSEMBLY REQUIREMENTS. REFER TO 1-AF105

FOR INTERIOR PARTITION TYPES & DETAILS.

10. REFER TO SHEET 1-AE705 FOR RATED PARTITION

PRIORITY AND RATED PARTITION INTERSECTIONS.

11. FURNITURE AND EQUIPMENT SHOWN NIC UNLESS

OTHERWISE NOTED.

12. PROVIDE 16 GA STUDS ON WET WALLS IN

RESTROOMS AND FOR THE DRINKING FOUNTAIN

WALL. 20 GA STUDS ON ALL OTHER WALLS.

13. SEAL ALL PENETRATIONS IN SUITE PERIMETER

WALLS.

14. RECESSED ACCESS DOORS LOCATED UNDER

EACH LAVATORY AND SINK LOCATED IN THE

WALL.

A

C

E

B

SECOND FLOOR KEY PLAN

AREA OF

WORK

FB1 = FIRE BARRIER 1HR

FB2 = FIRE BARRIER 2HR

SB1 = SMOKE BARRIER- 1 HOUR

NON-RATED INTERIOR PARTITION WALL

NON-RATED INTERIOR PARTITION WALL (WITH

INSULATION)

EXISTING WALL TO REMAIN

SEE AF105 FOR WALL TYPE CONSTRUCTION

0' 1'

6" 3"

1'

Gr ap hi c S ca le

: 1 /2"

1'-

0"

0' 4"

8" 1'

2'

Gr ap hi c S ca le

: 3 /32

1'

-0

0'

8' Gr ap hi c S ca le : 1

/16

1' -0

0' 8'

4' Gr ap hi c S ca le

: 1 /8"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 1 /4"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 3 /8"

1'-

0"

0' 2'

4' 1' Gr ap hi c S ca le : 1

/2"

1'- 0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 3 /4"

1'-

0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 1

1' -0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Spinklered

BI

M

VI

SN

- B eh av io ra l H ea lth C lin ic

R en ov at io n/

BH

C lin ic

R en ov at io n.

rv t

7/

/2

:4 9:

A

M

ENLARGED SECOND FLOOR PLAN

RCO TLZ

BID DOCUMENTS 589A4-19-103

1-AE102

Columbia Harry S. Truman Memorial Veterans Hospital

Columbia, Missouri

5/13/2021 (ADDENDUM

#1 - 7.16.21)

Fully Sprinklered

1/8" = 1'-0"1 ENLARGED SECOND FLOOR PLAN

Note Number Note

PROVIDE A NEW CARD READER. POWER SUPPLY AND DOOR CONTACT FOR

EACH DOOR ASSEMBLY AND INCORPORATE/TIE-IN ALL COMPONENTS TO

THE EXISTING ACCESS CONTROL SYSTEM SO THAT IT IS OPERATIONAL

PRIOR TO SUBSTANTIAL COMPLETION. REFER TO TELECOMMUNICATIONS

SHEET 1-ET102, DOOR SCHEDULE SHEET 1-AF101, SPECIFICATIONS, AND

ASSOCIATE HARDWARE SET FOR ADDITIONAL DETAILS.

2 NEW ROOF ACCESS DOOR. SEE SHEET 1-AE707 FOR NEW DOOR

DETAILS.SEE SHEET 1-AE105 FOR DIMENSIONS OF NEW DOOR OPENING.

INFILL WALL AT THIS LOCATION IN REPLACE OF DEMO'ED WINDOW. MATCH

EXISTING ADJACENT WALL CONSTRUCTION. SEE 1-AE105 FOR DIMENSIONS

OF NEW WALL OPENING AND WALL TYPE.

4 EXISTING EXPANSION JOINT TO REMAIN.

INSTALL NEW 2'-8" X 6'-2 5/8" WINDOW AND NEW BLINDS AT THIS LOCATION.

SEE SHEET 1-AE707 FOR NEW WINDOW DETAILS & SHEET 1-AF101 FOR

WINDOW SCHEDULE & WINDOW ELEVATION. SEE DETAIL 2/1-AE702 FOR

BLINDS.

6 CONTRACTOR TO SUPPLY/INSTALL NEW MAILBOXES. SEE DETAILS

6,7/1-AE501 FOR MAILBOX ELEVATIONS.

7 PROVIDE NEW FLOORING & NEW FLOORING FINISHES. SEE FINISH MATERIAL

SCHEDULE SHEET 1-AF103 FOR MORE INFORMATION.

8 HANDWAVE SENSOR ON BOTH SIDES. REFER TO DOOR SCHEDULE SHEET

1-AF101 AND ELECTRICAL DRAWINGS FOR MORE INFORMATION.

9 3 DRAWER FILE CABINET WITH LOCKS BELOW COUNTERTOP. SEE SHEET

1-AE501 & 1-AE503 FOR MILLWORK ELEVATIONS AND SECTIONS.

10 SOLID SURFACE (SS-1)TRANSACTION COUNTERTOP.SEE SHEET 1-AE501 &

1-AE503 FOR MILLWORK ELEVATIONS AND SECTIONS.

11 SOLID SURFACE (SS-1)ACCESSIBLE COUNTERTOP. SEE SHEET 1-AE501 &

1-AE503 FOR MILLWORK ELEVATIONS AND SECTIONS.

12 DEMO AND REPLACE EXISTING EXPANSION JOINT-MATCH EXISTING.

CARD READER & A-PHONE TO BE RELOCATED FROM EXISTING SOCIAL

WORK DOOR A213 TO THIS LOCATION. POWER SUPPLY AND DOOR CONTACT

FOR EACH DOOR ASSEMBLY AND INCORPORATE/TIE-IN ALL COMPONENTS

TO THE EXISTING ACCESS CONTROL SYSTEM SO THAT IT IS OPERATIONAL

PRIOR TO SUBSTANTIAL COMPLETION. REFER TO SHEET

1-ET102-TECHNOLOGOY SHEETS, DOOR SCHEDULE SHEET 1-AF101,

SPECIFICATION, AND ASSOCIATE HARDWARE SET FOR ADDITIONAL DETAILS.

14 CORNER GUARD WALL PROTECTION (FULL HEIGHT) TYP. ALL CORRIDOR

CORNERS - REFER TO SPEC SECTION 102600 FOR DETAILS

HANDRAIL AND BUMPER GUARD WALL PROTECTION ALONG LENGTH OF

WALL - REFER TO SPEC SECTION 102600 FOR DETAILS. TOP OF HANDRAIL TO

BE 34" A.F.F. TYP.

16 PROVIDE NEW 1" SOLID SURFACE SILL. SEE DETAILS ON SHEET 1-AE707.

17 PROVIDE HANDWAVE AUTOMATIC DOOR OPENING SYSTEM. REFER TO

DOOR SCHEDULE SHEET 1-AF101.

PROVIDE TOILET PARTITION WALLS, DOORS, AND ASSOCIATED

COMPONENTS-REFER TO SPEC SECTION 102113 FOR DETAILS.SEE SHEET

1-AE401/402 FOR TOILET ELEVATIONS.

19 PATCH, CLEAN, & REPAIR WALLS AFTER DEMO TO MATCH ADJACENT

SURFACES, TYP. ALL AREAS.

REINSTALL EXISTING CARD READER. POWER SUPPLY AND DOOR CONTACT

FOR EACH DOOR ASSEMBLY AND INCORPORATE/TIE-IN ALL COMPONENTS

TO THE EXISTING ACCESS CONTROL SYSTEM SO THAT IT IS OPERATIONAL

PRIOR TO SUBSTANTIAL COMPLETION. REFER TO SHEET

1-ET102-TECHNOLOGOY SHEETS, DOOR SCHEDULE SHEET 1-AF101,

SPECIFICATION, AND ASSOCIATE HARDWARE SET FOR ADDITIONAL DETAILS.

21 REPLACE EXISTING DOORS WITH NEW DOOR, DOOR HARDWARE, AND DOOR

FRAME. SEE SHEET 1-AF101 - DOOR SCHEDULE FOR MORE INFORMATION.

22 EXISTING DOORS TO REMAIN

EXISTING WINDOWS TO REMAIN. INSTALL NEW BLINDS AT ALL EXTERIOR

WINDOWS. CONTRACTOR TO PROVIDE & INSTALL BLINDS. SEE DETAIL

2/1-AE702.

24 PATCH, CLEAN, & REPAIR FLOORS WHERE NEEDED AFTER DEMO. LEVEL

FLOORS WHERE NEEDED. TYPICAL ALL AREAS.

25 PAINT NEW WALLS. SEE FINISH MATERIAL SCHEDULE SHEET 1-AF103 FOR

DETAILS. TYPICAL IN ALL AREAS.

PROVIDE NEW GYP. BD. (TAKE TO THE UNDERSIDE OF THE DECK) AND NEW

PAINT TO EXISTING WALLS -TYP. SEE FINISH MATERIAL SCHEDULE SHEET

1-AF103 FOR DETAILS. SEE SHEET 1-AF105 WALL TYPES.

27 REINSTALL EXISTING INDUCTION UNIT HEATER. SEE DETAIL 5/1-AE707.

28 INSTALL NEW WALL TYPE P03- 3 5/8" METAL STUD ON 5/8" GYP. BD AGAINST

EXISTING WALL.

INFILL WALL AT THIS LOCATION IN REPLACE OF DEMO'ED DOOR. MATCH

EXISTING ADJACENT WALL CONSTRUCTION. SEE 1-AE105 FOR DIMENSIONS

OF NEW WALL OPENING AND WALL TYPE.

EXISTING FIRE RATED WALL, MAINTAIN FIRE RATING. SEAL ALL

PENETRATIONS CREATED OR UNCOVERED DURING CONSTRUCTION. DEMO

AND REPLACE GYP.BD. AS REQUIRED FOR NEW WORK.

REINSTALL EXISTING CARD READER REMOVED FROM EXISTING IT ROOM.

POWER SUPPLY AND DOOR CONTACT FOR EACH DOOR ASSEMBLY AND

INCORPORATE/TIE-IN ALL COMPONENTS TO THE EXISTING ACCESS

CONTROL SYSTEM SO THAT IT IS OPERATIONAL PRIOR TO SUBSTANTIAL

COMPLETION. REFER TO SHEET 1-ET102-TECHNOLOGOY SHEETS, DOOR

SCHEDULE SHEET 1-AF101, SPECIFICATION, AND ASSOCIATE HARDWARE

SET FOR ADDITIONAL DETAILS.

32 1" ACRYLIC PANEL (AP-1) PRIVACY SCREEN. SEE MILLWORK ELEVATIONS

SHEET 1-AE501 FOR MORE INFORMATION. SEE DETAIL 6/1-AE702.

33 DRINKING FOUNTAIN WITH BOTTLE FILLER. SEE DETAIL 10/1-AE401.

FIRE EXTINGUISHER AND FIRE EXTINGUISHER CABINET. SEE FIRE

EXTINGUISHER CABINET DETAILS 4,5/1-AE702. REFER TO LIFE SAFETY PLAN

SHEET 1-GI103 FOR DETAILS. SEE SPEC SECTION 104413.

35 PROVIDE NEW PREFRABRICATED ROOF ACCESS STEEL STAIRS. SEE SHEET

1-AE707 FOR DETAILS.

36 INSTALL NEW WALL TYPE P03- 3 5/8" METAL STUD ON 5/8" GYP. BD AGAINST

EXISTING WALL ABOVE AND BELOW WINDOW, TYP.

NORTH

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02Revisions: Date:

Addendum #1 7.16.21

AREA PLAN LEGEND

KEY NOTES

FEC

FE

C

FEC

FEC

GENERAL NOTES:BARRIER LEGEND

AREA OF

WORK

FOURTH FLOOR KEY PLAN

AREA NOT IN CONTRACT

Na

Na

N

N

M

M

L

L

K

K

J

J

4.4

5.45.4

5.75.7

6.26.2

2.92.9

LaMa

Ma

Hb

HbJb

1-AE403

189 SF

EMG/SCI

180 SF

OIT

259 SF

PROCEDURE

ROOM

124 SF

CLEAN

SUPPLY

234 SF

PROCEDURE

ROOM

150 SF

PM&R

EXAM

ROOM 1

156 SF

PM&R

EXAM

ROOM 3

150 SF

PM&R

EXAM

ROOM 2

148 SF

PM&R

EXAM

ROOM 4

125 SF

PAIN

EXAM

47 SF

EXISTING

ELEC.

492A

145 SF

PAIN

SWAMP

53 SF

TOILET

171 SF

PM&R

SWAMP

103 SF

SOILED

HOLDING

54 SF

TOILET

74 SF

PAIN &

PMR

VVC/TM

97 SF

PAIN BH

99 SF

PAIN

PHARM

119 SF

PAIN

EXAM

ROOM 2

122 SF

PAIN

EXAM

ROOM 3

126 SF

PAIN

EXAM

ROOM 4

106 SF

MSA

CHECKIN/OUT

52 SF

WORKSTATION

71 SF

NURSE

NAVIGATOR

1-AE403

1 1

2 2 2

2 22

2 2 2 2

22 2 2

2 2

6 7

14 14 14 14 14 14 14 14

15 16

16 16

16 16 16 16

0C

0B

13492

485484483

481480479

491 490A 489

1-AE502

1-AE502

1-AE502

144 SF

NURSES

CORRIDOR

C498

CORRIDOR

C496

CORRIDOR

C495

CORRIDOR

C499

CORRIDOR

C497

2A

104 SF

CORRIDOR

C500

21 21 21 21 21 21 21

16 15

25 25 25

1 1

1 1

3A

3A

TYP. ALL AREAS

TYP. ALL AREAS

TYP. ALL AREAS TYP. ALL AREAS

TYP. ALL AREAS

TYP. ALL AREAS

1. CONTRACTOR TO FIELD VERIFY EXISTING

STRUCTURAL COLUMN SPACING AND OVERALL

BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY

VA AND ARCHITECT IF ANY DISCREPANCIES ARE

FOUND BETWEEN FIELD DIMENSIONS AND

DRAWINGS.

2. GENERAL CONTRACTOR (GC) SHALL VERIFY

DIMENSIONS OF OWNER FURNISHED EQUIPMENT

AND COORDINATE INSTALLATION WITH ALL

TRADES WHERE REQUIRED.

3. REFER TO FINISH SHEETS FOR PARTITION

PROTECTION INFORMATION INCLUDING BUT NOT

LIMITED TO ALL CORNER GUARD TYPES AND

LOCATIONS.

4. GENERAL CONTRACTOR (GC) SHALL INSTALL

IN-WALL 16 GA METAL BACKING FOR ALL

PARTITION-MOUNTED EQUIPMENT, ACCESSORIES,

PARTITION STOPS, ETC.

5. GENERAL CONTRACTOR (GC) SHALL INSTALL

FIRE-RETARDANT WOOD BLOCKING WITHIN WALLS

BASED ON CASEWORK ELEVATIONS AND ALL

INTERIOR PARTITION ELEVATIONS.

6. ALL INTERIOR WALLS SHALL RECEIVE

5/8" TYPE 'X' GYPSUM BOARD.

7. GENERAL CONTRACTOR (GC) SHALL PROVIDE

UL APPROVED FIRE-RESISTIVE PENETRATION

SYSTEMS AT ALL FIRE- RATED PARTITION

ASSEMBLY.

8. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED

AS NON-RATED SMOKE PARTITIONS.

9. ALL WALLS SHALL BE CONSTRUCTED FLOOR TO

DECK AND CONTAIN SOUND INSULATION AND

ACOUSTICAL CAULK. REFER TO 1-AF106 FOR

INTERIOR PARTITION TYPES & DETAILS.

10. REFER TO SHEET 1-AE705 FOR RATED PARTITION

DETAILS AND RATED PARTITION INTERSECTIONS.

11. FURNITURE AND EQUIPMENT SHOWN NIC UNLESS

OTHERWISE NOTED.

12. PROVIDE 16 GA STUDS ON WET WALLS IN

RESTROOMS AND FOR THE DRINKING FOUNTAIN

WALL. 20 GA STUDS ON ALL OTHER WALLS.

13. UNLESS OTHERWISE NOTED, DIMENSIONING ON

PLAN IS AS FOLLOWS:

-TO FACE OF MASONRY

-TO FACE OF CONCRETE

-TO FACE OF STUD IN FRAMED PARTITIONS

-GRIDLINES: TO CENTER LINE OF COLUMNS

14. RECESSED ACCESS DOORS LOCATED UNDER

EACH LABORATORY AND SINK LOCATED IN THE

WALL.

FB1 = FIRE BARRIER 1HR

FB2 = FIRE BARRIER 2HR

SB1 = SMOKE BARRIER- 1 HOUR

NON-RATED INTERIOR PARTITION WALL

NON-RATED INTERIOR PARTITION WALL (WITH

INSULATION)

EXISTING WALL TO REMAIN

SEE AF105 FOR WALL TYPE CONSTRUCTION

0' 1'

6" 3"

1'

Gr ap hi c S ca le

: 1 /2"

1'-

0"

0' 4"

8" 1'

2'

Gr ap hi c S ca le

: 3 /32

1'

-0

0'

8' Gr ap hi c S ca le : 1

/16

1' -0

0' 8'

4' Gr ap hi c S ca le

: 1 /8"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 1 /4"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 3 /8"

1'-

0"

0' 2'

4' 1' Gr ap hi c S ca le : 1

/2"

1'- 0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 3 /4"

1'-

0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 1

1' -0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Spinklered

BI

M

VI

SN

- B eh av io ra l H ea lth C lin ic

R en ov at io n/

BH

C lin ic

R en ov at io n.

rv t

7/

/2

:4 3:

P

M

ENLARGED FOURTH FLOOR PLAN

RCO EM

BID DOCUMENTS 589A4-19-103

1-AE104

Columbia Harry S. Truman Memorial Veterans Hospital

Columbia, Missouri

5/13/2021 (ADDENDUM

#1 - 7.16.21)

Fully Sprinklered

NORTH

Note Number Note

1 CORNER GUARD WALL PROTECTION (FULL HEIGHT) TYP. ALL CORRIDOR

CORNERS-REFER TO SPEC SECTION 102600 FOR DETAILS.

HANDRAIL AND BUMPER GUARD WALL PROTECTION ALONG LENGTH OF WALL -

REFER TO DIMENSION PLAN 1-AE106 AND SPEC SECTION 102600 FOR DETAILS.

TOP OF HANDRAIL TO BE 34" A.F.F.

EXISTING FIRE RATED WALL, MAINTAIN FIRE RATING. SEAL ALL PENETRATIONS

CREATED OR UNCOVERED DURING CONSTRUCTION. DEMO AND REPLACE

GYP.BD AS REQUIRED FOR NEW WORK.

3A

EXISTING FIRE RATED WALL. 1 HOUR RATED SMOKE BARRIER. MAINTAIN FIRE

RATING. SEAL ALL PENETRATIONS CREATED OR UNCOVERED DURING

CONSTRUCTION. DEMO AND REPLACE GYP.BD. AS REQUIRED FOR NEW WORK.

4 RELOCATED ELECTRICAL PANELS. SEE ELECTRICAL SHEET 1-EP102 FOR MORE

INFORMATION.

PROVIDE A TEMPORARY CONSTRUCTION BARRIER BETWEEN OCCUPIED AND

NON-OCCUPIED SPACE. FREE EGRESS TO THE STAIR ENCLOSURE IS

REQUIRED DURING CONSTRUCTION.

PROVIDE HANDWAVE ACTUATOR (OVERHEAD DOOR COMPANY OF CENTRAL

MISSOURI OR VA APPROVED EQUAL). REFER TO DOOR SCHEDULE SHEET

1-AF102.

7 PATCH, CLEAN, AND REPAIR WALLS AFTER DEMO. TYPICAL IN ALL AREAS.

8 PATCH, CLEAN, AND REPAIR FLOORS WHERE NEEDED AFTER DEMO. LEVEL

FLOORS WHERE NEEDED. TYPICAL IN ALL AREAS.

9 PAINT NEW WALLS. SEE FINISH MATERIAL SCHEDULE SHEET 1-AF104 FOR

DETAILS. TYPICAL IN ALL AREAS.

10 PROVIDE NEW FLOORING & NEW FLOORING FINISHES. SEE FINISH MATERIAL

SCHEDULE SHEET 1-AF104 FOR MORE INFORMATION.

PROVIDE NEW GYP. BD. (TAKE TO THE UNDERSIDE OF THE DECK) AND NEW

PAINT TO EXISTING WALLS -TYP. SEE FINISH MATERIAL SCHEDULE SHEET

1-AF104 FOR DETAILS. SEE SHEET 1-AF106 WALL TYPES.

12 MOVABLE SCREEN BY OWNER, NIC.

13 EXISTING DOOR TO REMAIN.

EXISTING WINDOWS TO REMAIN. INSTALL NEW BLINDS AT ALL EXTERIOR

WINDOWS. CONTRACTOR TO PROVIDE & INSTALL BLINDS. SEE DETAIL

2/1-AE702.

15 INSTALL NEW SOLID SURFACE (SS-1) TRANSACTION COUNTERTOP. SEE SHEET

1-AE502.

16 INSTALL NEW SOLID SURFACE (SS-1) ACCESSIBLE COUNTERTOP. SEE SHEET

1-AE502.

17 1" ACRYLIC PANEL (AP-1) PRIVACY SCREEN. SEE 6/1-AE702 & 1/1-AE502 FOR

MORE INFORMATION.

FIRE EXTINGUISHER AND FIRE EXTINGUISHER CABINET. SEE FIRE

EXTINGUISHER CABINET DETAILS 4,5/1-AE702. REFER TO LIFE SAFETY PLAN

SHEET 1-GI106 FOR DETAILS. SEE SPEC SECTION 104413.

PROVIDE A CARD READER. POWER SUPPLY AND DOOR CONTACT FOR EACH

DOOR ASSEMBLY AND INCORPORATE/TIE-IN ALL COMPONENTS TO THE

EXISTING ACCESS CONTROL SYSTEM SO THAT IT IS OPERATIONAL PRIOR TO

SUBSTANTIAL COMPLETION. REFER TO DOOR SCHEDULE SHEET 1-AF102,

SPECIFICATIONS, AND ASSOCIATE HARDWARE SET FOR ADDITIONAL DETAILS.

20 DRINKING FOUNTAIN WITH BOTTLE FILLER. SEE DETAIL 7/1-AE403.

21 INSTALL NEW WALL TYPE P03- 3 5/8" MTL. STUD WITH SOUND BATT INSULATION

ON 5/8" GYP. BD AGAINST EXISTING WALL.

22 INFILL WALL AT THIS LOCATION IN REPLACE OF DEMO'ED DOOR.

23 FURR OUT AS NEEDED WITH P00 WALL TYPE. SEE SHEET 1-AE106.

24 ROLL DOWN LOCKABLE SECURITY GATE. SEE DETAIL 1/1-AE702 . SEE SPEC

SECTION 083300 FOR MORE INFORMATION.

25 WALL AT THIS LOCATION DOES NOT GO TO DECK. FRAME WALLS AROUND

DUCTS. SEE DETAIL 3/1-AE702.

INSTALL NEW 1/16" THICK LEAD LINED GYP. BD. LEAD LINING HEIGHT GOES UP

TO 7'-0" A.F.F. ON INTERIOR SIDE AT THIS LOCATION. CONTRACTOR TO PATCH

AND REPAIR WALL TO MEET WALL TYPE CONSTRUCTION. SEAL ALL

PENETRATIONS AS NEEDED.

INSTALL NEW 5/8" THICK TYPE 'X' GYP. BD. ON INTERIOR SIDE AT THIS

LOCATION. CONTRACTOR TO PATCH AND REPAIR WALL TO MEET R06 WALL

TYPE CONSTRUCTION. SEAL ALL PENETRATIONS AS NEEDED.

PROVIDE AUTOMATIC DOOR OPENING SYSTEM WITH PUSH BUTTON RELEASE

AT MSA CHECKIN DESK. REFER TO DOOR SCHEDULE SHEET 1-AF102. SEE

TECHNOLOGY SHEET ET104 FOR MORE INFORMATION.

1/4" = 1'-0"1 ENLARGED FOURTH FLOOR PLAN

NOTE: ALL FURNITURE SHOWN IS FOR LAYOUT PURPOSES, N.I.C. UNLESS

OTHERWISE NOTED. SEE EQUIPMENT PLAN FOR MORE DETAILS.

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02Revisions: Date:

Addendum #1 7.16.21

RCP NOTES

RCP LEGEND

WAP

WAP

CAM

WAP

N T

CAM

CAM

CAM

CAM

WAP

S

S

S

CAM

CAM

CAM

WAP

WAP

WAP

WAP

WAP

WAP

S

S

S S

S

S

S

A1

A1 F

A1

V V

V

O

O

E

E E

D

D

D

O

D

O O

E

D

E

E

D

D

D

D

D

D

D

D

D

D

K3

K3

E

D

K

K K

O

D D

D D D

D

OC

OC

VC

A3

OC

OC

OC

OC

OC

OC

OC

LS

LS LS

LS

OC OC

LS LS

LS

OC

VC

OC

OC

A3A1

A1A1

A1 A1 A1

A1

A1

A3

A1

A A1

A1

A

A

A3

V1

V1

A

A3

A1

A1

A1 A1 A

A1

OC

VC

VC

VC

VC VC

A1

A

SD

S1

1-TV

1-

TV

CAM

CAM

CAM

S

S

S

CAM

CAM

CAM

S1

1-

TV

1-TV

1-

TV

CAM

CAM

CAM

N N

N N N

N N

CAM

S

S

S

CAM

CAM

CAM

OC

OC

VC

A3

OC

OC

OC

OC

OC

OC

OC

LS

LS LS

LS

OC OC

LS LS

LS

OC

VC

OC

OC

A3A1

A1A1

A1 A1

A1

A1

A1

A A1

A1

A

A

A3

V1

V1

A

A3

A1

A1

A1 A1 A

A1

OC

VC

VC

VC

VC VC

A1

A

SD

SW SW SW SW

SW SW

SW SW

SW

SW

OC

OC

{LD1}

{LS3}

{LD1}

{LD1}

{LD1}

{LD1}

{LS1}

{LD1}

{LS3}

{LS3}{LD1}

{LS3}

{LD1}

{LD1}

{LD1} {LD1}

{LS3}

{LS3}

{LS3}

{LS3}

{LS3}

{LD1} {LD1}

{LS3}

{LD1}

{LS1}

{LD1}

{LS1}

VC

{LS3}

OC

OC

{LS2}

{LS2}

{LS1}

{LS1}

{LS2}

OC

SW

VC

{LS2}

A3

SD

SD

AR

D

A1

A1A1

A1

A3 A3

A3

A1

A

A1

V1

V1 A

A3

A1

A1

A1 A

1-

TV

1-TV

S1

1-TV

CAM

CAM

CAM

S

S

S

CAM

CAM

AREA PLAN LEGEND

KEY NOTES

RCP SYMBOLS

LIGHTING FIXTURE SCHEDULE

1. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT

OF ANY DIMENSIONAL DISCREPANCIES

DISCOVERED DURING CONSTRUCTION.

2. REFER TO ELECTRICAL DRAWINGS FOR LOCATION

OF EMERGENCY LIGHTING.

3. CENTER CEILING AND LIGHTS IN ALL SPACES

WHERE POSSIBLE, U.N.O.

4. REFER TO ELECTRICAL DRAWINGS FOR

LOCATIONS OF UNDER-CABINET LIGHT FIXTURES.

5. GYP. BD. SOFFITS ABOVE UPPER CABINETS SHALL

EXTEND TO TOP OF CABINET (7'-0" U.N.O.).

6. THIS SHEET IS FOR LAYOUT ONLY. SEE

ELECTRICAL AND MECHANICAL DRAWINGS FOR

EXACT FIXTURE QUANTITY. ALL SWITCHES,

OUTLETS, LIGHTS, DIFFUSERS, ETC. MUST BE

LOCATED PER ARCHITECTURAL DRAWINGS

WHERE APPLICABLE.

7. PROVIDE ACCESS PANELS IN GYPSUM CEILINGS

WHERE REQUIRED TO ACCESS ABOVE CEILING

EQUIPMENT. (SEE SPECS)

8. ALL CEILINGS SHALL BE 9'-0" AFF U.N.O.

9. REFER TO FINISH DRAWINGS FOR CEILING GRID

AND PANEL TYPE AND SIZE.

10. BOTTOM OF GYP. BD. BULKHEADS SHALL BE 8'-6"

AFF U.N.O.

11. ALL PARTITION WALLS SHALL EXTEND TO

UNDERSIDE OF DECK ABOVE U.N.O.

12. GYP. BD. CEILINGS SHALL BE CONSTRUCTED PER

SHEET 1-AE706 OR AT GENERAL CONTRACTOR

(GC) OPTION TO USE AN APPROVED EQUAL

SYSTEM (FOR EX. - USG CROSS-TEE SUSPENSION

SYSTEM) ALL FRAMING MEMBERS SHALL BE

ADEQUATELY SIZED FOR THE REQUIRED

SPAN/SPACING. REFER TO SPECS FOR

ADDITIONAL GYP. BD. INFORMATION. GYP. BD.

CEILINGS SHALL BE INSTALLED PER ASTM C840.

13. ALL OFFICES SHALL HAVE DIMMERS. SEE

ELECTRICAL SHEETS FOR MORE INFORMATION.

14. GROUP ROOMS SHALL HAVE THE ABILITY TO

DIM 60%-50%. SEE ELECTRICAL SHEETS FOR

MORE INFORMATION.

MECHANICAL SUPPLY DIFFUSER

MECHANICAL RETURN GRILLE

MECHANICAL EXHAUST GRILLE

24" X 24" ACOUSTICAL CEILING

PANEL AND GRID

GYPSUM BOARD CEILING OR

SOFFIT

2' x 2' LED FLUORESCENT

FIXTURE

RECESSED CAN DOWNLIGHT

CEILING ELEVATION A.F.F.X'-X"

EXIT SIGN

2' x 2' LED FIXTURE -

EMERGENCY NIGHT LIGHT

Na N M L

1.91.9

2.82.8

3.73.7

4.64.6

5.55.5

6.36.3

K J H G F

7.27.2

8.38.3

9.19.1

49 SF

A207

EXIST.

ELEC

204 SF

A200

CLINIC

OFFICE

154 SF

A203

CLINIC

OFFICE

182 SF

A204

CLINIC

OFFICE

GROUP ROOM

A218

GROUP ROOM

A219

GROUP ROOM

A220

WOMEN'S

A221

MEN'S

A222EXIST. IT

A217

EXIST. ELEC. CLO.

A216

152 SF

A202

CLINIC

OFFICE

169 SF

A208

TMS

ROOM

163 SF

A210

TMS

ROOM

183 SF

A206

PSYCH.

RES

197 SF

A201

PSYCH.

RES

94 SF

A201B

OBSERVATION

24 SF

A206A

EXIST.

STRG

178 SF

A205

PSYCH.

RES

372 SF

A224

WAITING

398 SF

A223

WAITING

MAIL AREA

89 SF

A223B

WORK

AREA

64 SF

A223C

COPIER/PAPER

STORAGE

AREA

125 SF

A223A

CHECKOUT/CHECK

IN

112 SF

A209

CARE

COORDINATOR

111 SF

A211

CARE

COORDINATOR

74 SF

A214

STAFF

RESTROOM 72 SF

A215

HAC

9' - 1"A.F.F

9' - 1"A.F.F

9' - 0"A.F.F

9' - 1"A.F.F

9' - 1"A.F.F 9' - 1"A.F.F

9' - 0"A.F.F 9' - 0"A.F.F

9' - 0"A.F.F

9' - 0"A.F.F

9' - 1"A.F.F

9' - 0"A.F.F

9' - 0"A.F.F

9' - 1"A.F.F

9' - 1"A.F.F

9' - 0"A.F.F

8' - 0"A.F.F

7' - 6"A.F.F

368 SF

C2A04

CORRIDOR

7' - 6"A.F.F

1235 SF

A226

GROUP

ROOM

WAITING

AREA

8' - 0"A.F.F

8' - 0"A.F.F

7' - 6"A.F.F

63 SF

C2A02

CORRIDOR

295 SF

C2A01

CORRIDOR

154 SF

C2A03

CORRIDOR

143 SF

C2A05

CORRIDOR

861 SF

C2A07

CORRIDOR

567 SF

C2A08

CORRIDOR

EXP.

EXP.

7' - 6"A.F.F

EXP.

1-AE703

1-AE703 1

1-AE703

1-AE703

8' - 0"A.F.F

8' - 0"A.F.F

8' - 0"A.F.F

EXP.

64 SF

EXIST. SOC WRK

A212

63 SF

EXIST. SOC WRK

A213

1-AE703

65 SF

A200A

VESTIBULE

EXISTING SOFFIT TO REMAIN

9' - 0"A.F.F

9' - 1"A.F.F

9' - 0"A.F.F

9' - 0"A.F.F

EXIST. IT

A217

EXP.

1-AE703

8' - 0"A.F.F

8' - 0"A.F.F

8' - 0"A.F.F

9' - 0"A.F.F

4.4

8' - 0"A.F.F

8' - 0"A.F.F

9' - 0"A.F.F 5

1-AE703

1-AE703

1-AE703

8' - 0"A.F.F

8' - 0"A.F.F

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

1 TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

1-AE702

Sim 4 4 4 4 4 4

AREA NOT IN CONTRACT

A

C

E

B

SECOND FLOOR KEY PLAN

AREA OF

WORK

OC

NURSE CALL DOME LIGHT WALL

MOUNTED

A

FIRE ALARM AUDIO/VISUAL

NOTIFICATION DEVICE-CEILING

MOUNTED.

CAM

LS

OCCUPANCY SENSOR

A1 A3

DAYLIGHT LEVEL SENSOR

CLOSED CIRCUIT CAMERA (CCTV)

CEILING MOUNTED

N

S SPEAKER

CLOSED CIRCUIT CAMERA (CCTV)CAM

VC VACANCY SENSOR

WAP CEILING INFORMATION OUTLET

FIRE ALARM VISUAL NOTIFICATION

DEVICE - WALL MOUNTED

V1

WALL CONTROL STATIONSW

NURSE CALL STATIONN

SMOKE,FIRE/SMOKE

DAMPER CONTROLLER

ARD

FIRE ALARM MANUAL PULL

STATION

F

FIRE ALARM SMOKE,

SMOKE DAMPER

SD

SD FIRE ALARM DUCT SMOKE

DETECTOR

D DIMMER LED

A FIRE ALARM AUDIO/VISUAL

NOTIFICATION DEVICE- WALL

MOUNTED.

A1 A3

S SWITCH

{LD}

{LS}

LIGHT DIMMER

LIGHT SENSOR

0' 1'

6" 3"

1'

Gr ap hi c S ca le

: 1 /2"

1'-

0"

0' 4"

8" 1'

2'

Gr ap hi c S ca le

: 3 /32

1'

-0

0'

8' Gr ap hi c S ca le : 1

/16

1' -0

0' 8'

4' Gr ap hi c S ca le

: 1 /8"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 1 /4"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 3 /8"

1'-

0"

0' 2'

4' 1' Gr ap hi c S ca le : 1

/2"

1'- 0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 3 /4"

1'-

0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 1

1' -0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Spinklered

BI

M

VI

SN

- B eh av io ra l H ea lth C lin ic

R en ov at io n/

BH

C lin ic

R en ov at io n.

rv t

7/

/2

:5 4:

P

M

SECOND FLOOR REFLECTED CEILING PLAN

RCO EM

BID DOCUMENTS 589A4-19-103

1-AE107

Columbia Harry S. Truman Memorial Veterans Hospital

Columbia, Missouri

5/13/2021 (ADDENDUM

#1 - 7.16.21)

Fully Sprinklered

1/8" = 1'-0"1 SECOND FLOOR REFLECTED CEILING PLAN

NORTH

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

Note Number Note

1 REINSTALL (67) EXISTING 2'X2' LIGHT FIXTURES, TYP. INSTALL AN

ADDITIONAL (112) NEW 2'X2' LIGHT FIXTURES FOR A TOTAL OF (179) LIGHT

FIXTURES NEEDED.

2 12"X12" ACCESS PANELS FOR VALVES.

3 EXISTING CEILING GRID, AND (4) 2'X2' LIGHTS TO REMAIN.

4 INSTALL NEW BLINDS AT ALL EXTERIOR WINDOWS. CONTRACTOR TO

PROVIDE & INSTALL BLINDS. SEE DETAIL 2/1-AE702.

Count Level Phase Created

14 LEVEL 02 New Construction Downlight - Recessed Can: 6" Incandescent - 120V: 14 16 LEVEL 02 New Construction Downlight - Recessed Can: 8" Incandescent - 120V: 16 1 LEVEL 02 New Construction Downlight - Recessed Can: 8" Incandescent - 277V: 1 5 LEVEL 02 New Construction Family1: Toilet light: 5 1 LEVEL 02 New Construction Lighting - Troffer - 2x4 Direct / Indirect (Center Basket): 2'x4'(2 Lamp): 1 1 LEVEL 02 New Construction Lighting - Troffer Light - Lens: 1'x4'(2 Lamp): 1 184 LEVEL 02 New Construction Lighting - Troffer Light - Lens: 2'x2'(2 Lamp): 184 2 LEVEL 02 New Construction Lighting - Troffer Light - Lens: 2'x4'(2 Lamp): 2 Grand total: 224

Revisions: Date:

Addendum #1 7.16.21

360o

180o

TYP. ALL

WINDOWS

TYP.

TYP.

11111

1 1

NEW 1" SOLID SURFACE SILL

SEALANT AND BACKER ROD

EXTRUDED

ALUMINUM SILL

(MATCH EXISTING)

SEALANT

1"

GROUT

NEW FIXED ALUMINUM

WINDOW FRAME

NEW 3 5/8" METAL STUD

WITH ACOUSTICAL BATT

INSULATION ON 5/8"

GYP.BD.

EXISTING MASONRY

WALL

REMOVE, SALVAGE, AND

REINSTALL EXISTING

INDUCTION UNIT HEATEREXISTING CEMENT

GROUT FILLED

CAVITY

FLASHING

AS NEEDED

1/2"

DIM.

PARTITION 1/2"

D O

O R

D

IM

2"

PARTITION AS SCHED.

H.M. FRAME

CONT. SEALANT

(BOTH SIDES)

DOOR AS SCHED.

METAL STUD

TRACK - GAUGE TO

MATCH STUDS

+ 1"

PARTITION WIDTH

LEVEL 02

12' - 8"

DOOR AS SCHED.

DOOR

THRESHOLD

DOOR FRAME BEYOND

BRICK BEYOND

EXISTING BUILT UP

ROOF OVER RIGID

INSULATION

1-AE707

EXISTING MASONRY

WALL

NEW PHP

SYSTEMS/DESIGN

(BASIS OF DESIGN OR

VA APPROVED EQUAL)

PREFABRICATED

STEEL ROOF ACCESS

STAIRS AND HANDRAIL

D O

O R

S

IL

L H

EI

G

H T

1'

/4

1/2"

DIM.

PARTITION 1/2"

D O

O R

D

IM

2"

PARTITION AS SCHED.

H.M. FRAME

CONT. SEALANT

(BOTH SIDES)

DOOR AS SCHED.

+ 1"

PARTITION WIDTH

DOUBLE METAL STUDS

AT JAMBS - TYP.

SHIM AS REQUIRED

DOOR AS SCHED.

+ 1"

PARTITION WIDTH

1/ 8"

1/8" CLEARANCE ABOVE

THRESHOLD

DOOR

THRESHOLD

EXTRUDED ALUMINUM

DOOR FRAME BEYOND

3/ 4"

1-AF101 1

NEW FIXED

ALUMINUM WINDOW

FRAME

NEW 3 5/8" STUD WITH

ACOUSTICAL BATT

INSULATION ON 5/8" GYP. BD.

4" FACE BRICK

1" SOLID SURFACE

SILL

NEW EXTRUDED

ALUMINUM SILL

SEALANT & BACKER

ROD

5/8"

FLASHING AS

NEEDED

FLASHING AS NEEDED

TO COVER PLYWOOD

1"

CONCRETE BLOCK

CEMENT GROUT

FILLED CAVITY

NEW 3 5/8" FACE BRICK

SEALANT AND

BACKER ROD

HOLLOW METAL

FRAME

WOOD SHIM

SEALANT AND

BACKER ROD

DOOR AS SCHEDULED

NEW 3 5/8" METAL STUD WITH

ACOUSTICAL BATT INSULATION ON

5/8" GYP.BD.

D O

O R

D

IM

2"

7/

8"

DOOR AS SCHED.

DOOR FRAME BEYOND

NEW 3 5/8" METAL STUD

WITH ACOUSTICAL BATT

INSULATION ON 5/8" GYP.

BD

SEALANT AND

BACKER ROD

HOLLOW METAL

FRAME

WOOD SHIM

SEALANT AND

BACKER ROD

WOOD BLOCKING

2" D

O O

R D

IM

EXISTING WALL

NEW 7/8" HAT

CHANNEL FURRING

METAL LATH ON

5/8" GYP. BD.

CONCRETE BLOCK

EXISTING WALL

NEW FIXED ALUMINUM

WINDOW FRAME

NEW CEILING- SEE RCP

SEALANT & BACKER ROD

NEW GYP. BD. OVER

EXISTING WALL

SEALANT & BACKER ROD

NEW 7/8" HAT

CHANNEL FURRING

METAL LATH ON 5/8"

GYP. BD

NEW 3 5/8" METAL STUD

WITH ACOUSTICAL BATT

INSULATION ON 5/8" GYP.

BD

WOOD BLOCKING

9' - 1"

FLASHING AS NEEDED

WOOD SHIM

1-AE707

1-AE707

A2

B

-9

AE707

-6

AE707

1-

AF

-6

AE707

NEW PREFABRICATED

ROOF ACCESS STAIRS

4'

0"

6' - 2 15/16"

1/2"

DIM.

PARTITION 1/2"

D O

O R

D

IM

2"

PARTITION AS SCHED.

H.M. FRAME

CONTINUOUS HINGE

CONT. SEALANT

(BOTH SIDES)

DOOR AS SCHED.

+ 1"

PARTITION WIDTH

DOUBLE METAL STUDS

AT JAMBS - TYP.

SHIM AS REQUIRED

0' 1'

6" 3"

1'

Gr ap hi c S ca le

: 1 /2"

1'-

0"

0' 4"

8" 1'

2'

Gr ap hi c S ca le

: 3 /32

1'

-0

0'

8' Gr ap hi c S ca le : 1

/16

1' -0

0' 8'

4' Gr ap hi c S ca le

: 1 /8"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 1 /4"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 3 /8"

1'-

0"

0' 2'

4' 1' Gr ap hi c S ca le : 1

/2"

1'- 0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 3 /4"

1'-

0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 1

1' -0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Spinklered

BI

M

VI

SN

- B eh av io ra l H ea lth C lin ic

R en ov at io n/

BH

C lin ic

R en ov at io n.

rv t

7/

/2

:4 4:

P

M

SECOND FLOOR WINDOW, DOOR & STAIR

DETAILS

MK EM

BID DOCUMENTS 589A4-19-103

1-AE707

Columbia Harry S. Truman Memorial Veterans Hospital

Columbia, Missouri

5/13/2021 (ADDENDUM

#1 - 7.16.21)

Fully Sprinklered

3" = 1'-0"5 WINDOW SILL DETAIL

3" = 1'-0"4 DOOR HEAD DETAIL @ MTL. STUD WALL

1 1/2" = 1'-0"8 DOOR SILL DETAIL @ EXISTING WALL

3" = 1'-0"3 DOOR JAMB DETAIL @ MTL. STUD WALL

3" = 1'-0"1 DOOR SILL DETAIL @ MTL. STUD WALL

3" = 1'-0"6 WINDOW JAMB DETAIL

3" = 1'-0"9 DOOR JAMB DETAIL

3" = 1'-0"10 DOOR HEAD @ EXISTING WALL

3" = 1'-0"7 WINDOW HEAD DETAIL

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

3/4" = 1'-0"11 ENLARGED PLAN @ ROOF ACCESS DOOR

3" = 1'-0"2

DOOR JAMB @ RESTROOMS

(CONTINUOUS HINGE)

Revisions: Date:

FEC

FE

C

FEC

FEC

GENERAL NOTES:AREA PLAN LEGEND

BARRIER LEGEND

ACQ/INS

FURNISHED/INSTALLED NOTE:

VV- GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

VC- GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

CC- CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

Na

Na

N

N

M

M

L

L

K

K

J

J

4.4

5.45.4

5.7

6.26.2

6.76.7

2.92.9

JaLaMa

Ma

Hb

HbJb

21 21

TYP.TYP.

180 SF

OIT

18 1920

16 4

18 20 9

150 SF

PM&R EXAM ROOM 1

150 SF

PM&R EXAM ROOM 2

156 SF

PM&R EXAM ROOM 3

148 SF

PM&R EXAM ROOM 4

189 SF

EMG/SCI

71 SF

NURSE NAVIGATOR

478 74 SF

PAIN & PMR VVC/TM

97 SF

PAIN BH

99 SF

PAIN PHARM

481 119 SF

PAIN EXAM ROOM 2

122 SF

PAIN EXAM ROOM 3

126 SF

PAIN EXAM ROOM 4

52 SF

WORKSTATION

54 SF

TOILET

171 SF

PM&R SWAMP

125 SF

PAIN EXAM

47 SF

EXISTING ELEC.

492A

103 SF

SOILED HOLDING

53 SF

TOILET

145 SF

PAIN SWAMP

259 SF

PROCEDURE ROOM

124 SF

CLEAN SUPPLY

234 SF

PROCEDURE ROOM

106 SF

MSA CHECKIN/OUT

4701-AE110B

5 1

1-AE110E 5

1-AE110E

1-AE110C

1-AE110F 10

1-AE110B7

1-AE110C2

1-AE502

1-AE502

1-AE502

1-AE110F 2

1-AE110D

1-AE110D

1-AE110B

3 Sim

Si m

Si m

1-AE110B

3Sim

Si m

Si m

1-AE110B

2Sim

Si m

3 Sim

Si m

SEE PM&R EXAM ROOM1

FOR EQUIPMENT KEYNOTES

SEE PM&R EXAM ROOM1

FOR EQUIPMENT KEYNOTES

SEE PM&R EXAM ROOM1

FOR EQUIPMENT KEYNOTES

SEE PAIN EXAM ROOM2

FOR EQUIPMENT KEYNOTES

SEE PM&R EXAM ROOM2

FOR EQUIPMENT KEYNOTES

1-AE110D

3 Sim

Si m

4Sim

1-AE502

7Sim

1-AE502

1-AE110D

3 Sim

Si m

4Sim

1-AE110F

6 Sim

Si m

Si m

9Sim

1-AE502 3

Si m

46 46

1-AE5024

Si m

TYP.

TYP.

1-AE502 5

1-AE110D

1-AE110D

1-AE110B

1-AE110F

1-AE110F

1-AE110C

144 SF

NURSES

472 1-AE110B

1-AE110E

1-AE110E

180 SF

CORRIDOR

C498

321 SF

CORRIDOR

C496

259 SF

CORRIDOR

C499

316 SF

CORRIDOR

C495

14 14

11 11

11 11

2'

6" 2'

0"

2'

0"

2'

0" 2'

0"

2'

6"

2Sim

2 Sim

Si m

Si m

1-AE403

11 11

152 SF

CORRIDOR

C497

1-AE401

50 50

4"

AREA OF

WORK

FOURTH FLOOR KEY PLAN

1. CONTRACTOR TO FIELD VERIFY EXISTING

STRUCTURAL COLUMN SPACING AND OVERALL

BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY

VA AND ARCHITECT IF ANY DISCREPANCIES ARE

FOUND BETWEEN FIELD DIMENSIONS AND

DRAWINGS.

2. GENERAL CONTRACTOR (GC) SHALL VERIFY

DIMENSIONS OF OWNER FURNISHED EQUIPMENT

AND COORDINATE INSTALLATION WITH ALL

TRADES WHERE REQUIRED.

3. REFER TO FINISH SHEETS FOR PARTITION

PROTECTION INFORMATION INCLUDING BUT NOT

LIMITED TO ALL CORNER GUARD TYPES AND

LOCATIONS.

4. GENERAL CONTRACTOR (GC) SHALL INSTALL

IN-WALL 16 GA METAL BACKING FOR ALL

PARTITION-MOUNTED EQUIPMENT, ACCESSORIES,

PARTITION STOPS, ETC.

5. GENERAL CONTRACTOR (GC) SHALL INSTALL

FIRE-RETARDANT WOOD BLOCKING WITHIN WALLS

BASED ON CASEWORK ELEVATIONS AND ALL

INTERIOR PARTITION ELEVATIONS.

6. ALL INTERIOR WALLS SHALL RECEIVE

5/8" TYPE 'X' GYPSUM BOARD.

7. GENERAL CONTRACTOR (GC) SHALL PROVIDE

UL APPROVED FIRE-RESISTIVE PENETRATION

SYSTEMS AT ALL FIRE- RATED PARTITION

ASSEMBLY.

8. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED

AS NON-RATED SMOKE PARTITIONS.

9. ALL WALLS SHALL BE CONSTRUCTED FLOOR TO

DECK AND CONTAIN SOUND INSULATION AND

ACOUSTICAL CAULK. REFER TO 1-AF106 FOR

INTERIOR PARTITION TYPES & DETAILS.

10. REFER TO SHEET 1-AE705 FOR RATED PARTITION

DETAILS AND RATED PARTITION INTERSECTIONS.

11. FURNITURE AND EQUIPMENT SHOWN NIC UNLESS

OTHERWISE NOTED.

12. PROVIDE 16 GA STUDS ON WET WALLS IN

RESTROOMS AND FOR THE DRINKING FOUNTAIN

WALL. 20 GA STUDS ON ALL OTHER WALLS.

13. UNLESS OTHERWISE NOTED, DIMENSIONING ON

PLAN IS AS FOLLOWS:

-TO FACE OF MASONRY

-TO FACE OF CONCRETE

-TO FACE OF STUD IN FRAMED PARTITIONS

-GRIDLINES: TO CENTER LINE OF COLUMNS

14. RECESSED ACCESS DOORS LOCATED UNDER

EACH LABORATORY AND SINK LOCATED IN THE

WALL.

AREA NOT IN CONTRACT

FB1 = FIRE BARRIER 1HR

FB2 = FIRE BARRIER 2HR

SB1 = SMOKE BARRIER- 1 HOUR

NON-RATED INTERIOR PARTITION WALL

NON-RATED INTERIOR PARTITION WALL (WITH

INSULATION)

EXISTING WALL TO REMAIN

SEE AF105 FOR WALL TYPE CONSTRUCTION

0' 1'

6" 3"

1'

Gr ap hi c S ca le

: 1 /2"

1'-

0"

0' 4"

8" 1'

2'

Gr ap hi c S ca le

: 3 /32

1'

-0

0'

8' Gr ap hi c S ca le : 1

/16

1' -0

0' 8'

4' Gr ap hi c S ca le

: 1 /8"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 1 /4"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 3 /8"

1'-

0"

0' 2'

4' 1' Gr ap hi c S ca le : 1

/2"

1'- 0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 3 /4"

1'-

0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 1

1' -0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Spinklered

BI

M

VI

SN

- B eh av io ra l H ea lth C lin ic

R en ov at io n/

BH

C lin ic

R en ov at io n.

rv t

7/

/2

:5 2:

P

M

FOURTH FLOOR EQUIPMENT PLAN

RCO EM

BID DOCUMENTS 589A4-19-103

1-AE110A

Columbia Harry S. Truman Memorial Veterans Hospital

Columbia, Missouri

5/13/2021 (ADDENDUM

#1 - 7.16.21)

Fully Sprinklered

1/4" = 1'-0"1 FOURTH FLOOR EQUIPMENT PLAN

NORTH

NOTE

NUMBER JSN# ITEM NAME ACQ/INS

1 F0205 CHAIR, SIDE WITH ARMS V/V

2 F0340 STOOL, SELF ADJUSTING V/V

3 M9066 TABLE, EXAM/TREATMENT, HI-LOW V/V

4 M3070 HAMPER, LINEN V/V

5 F2010 BASKET,WASTEPAPER,STEP ON V/V

6 F3200 CLOCK, BATTERY, 12" DIAMETER V/V

7 A5106 WASTE DISPOSAL UNIT, SHARPS W/GLOVE

DISPENSER

V/C

8 A5180 TRACK, CUBICLE, SURFACE MOUNTED, WITH

CURTAIN. SEE SPEC SECTION 102123.

C/C

9 M1620 HOLDER, CHART, PATIENT V/C

10 A5075 DISPENSER, SOAP, DISPOSABLE V/C

11 A5077 DISPENSER, HAND SANITIZER, HANDS FREE V/C

12 PT045 BASE CABINET, ADA SINK C/C

13 A5080 DISPENSER, PAPER TOWEL, SS SURFACE

MOUNTED

V/C

14 N/A COMPUTER DESK V/V

15 F2000 BASKET, WASTE PAPER, ROUND, METAL V/V

16 M1801 COMPUTER, MICROPROCESSING, W/FLAT PANEL

MONITOR

V/V

17 F0280 CHAIR, SWIVEL, LOW BACK V/V

18 M4200 OTOSCOPE/OPHTHALMOSCOPE, WALL MOUNTED V/C

19 A1132 RAIL ( WELCH ALLYN - BASIS OF DESIGN OR VA

APPROVED EQUAL), ACCESSORY MOUNTING, 48"

C/C

20 M4100 SPHYGMOMANOMETER, ANEROID, WALL

MOUNTED

V/V

21 A5145 HOOK, GARMENT, TRIPLE, SS, SURFACE

MOUNTED

V/V

22 CS140 SINK, SS, COMPARTMENT (SEE PLUMBING

FIXTURE #P-528).

C/C

23 A1012 TELEPHONE, WALL MOUNTED, 1 LINE V/V

24 P3100 LAVATORY, VITREOUS CHINA C/C

25 M8810 MAYO STAND V/V

26 F0355 FOOTSTOOL, STRAIGHT V/V

27 M4116 VITAL SIGNS MONITOR V/V

28 M4255 IV STAND V/V

29 F0420 5 DRAWER FILE CABINET V/V

30 M4665 STRETCHER, RECOVERY, SURGICAL V/V

31 M3073 BASKET, INFECTIOUS WASTE, STEP-ON V/V

32 M7905 OXIMETER, PULSE V/V

33 E0930 LOCKER, SUPPLY, 6 DRAWERS, MOBILE, 29WX20D V/V

34 P-709 BRADLEY DECK MOUNT EYEWASH, HAND HELD.

SEE PLUMBING FIXTURE SCHEDULE ON SHEET

P-000, #P-709.

C/C

35 M4020 SCALE, PERSON WEIGHING, HIGH CAPACITY V/V

36 M7725 ELECTROMYOGRAPH V/V

37 E0945 CART, COMPUTER, MOBILE V/V

38 M3072 FRAME, INFECTIOUS WASTE BAG WITH LID V/V

39 E0123 WORKSTATION, STRAIGHT, FREE STANDING, 72W V/V

40 M4266 PUMP, VOLUMETRIC, INFUSTION, MULTIPLE LINE V/V

41 M8830 STRETCHER, MOBILE, CRS, 9 POSITION V/V

42 A1200 OVERHEAD LIFT SYSTEM. SEE SPEC SECTION

117300.

V/V

43 F2020 CAN, TRASH, 44 GALLON V/V

44 A6046 ARTWORK, DECORATIVE, WITH FRAME V/V

45 M1803 WORKSTATION, COMPUTER, WALL MOUNTED V19 V/V

46 M1803 PRINTER,/COPIER/FAX COMBINATION V/V

47 A5107 DISPENSER, GLOVE,SURGICAL-EXAMINATION

WALL MOUNTED

V/C

48 A6135 SHUTTER, ROLL DOWN. SEE SPEC SECTION

083300 FOR MORE INFORMATION.

C/C

49 P-502 INTEGRAL SINK W/COUNTERTOP. SEE PLUMBING

FIXTURE SCHEDULE.

C/C

50 N/A SOLID SURFACE WORKSURFACE. VA TO

PROVIDE.

V/V

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02Revisions: Date:

FE

C

FEC

FEC

1-AE502

2' - 0" 2' - 0" 2' - 6"

2' - 6"2' - 0"2' - 0"

1920 18 2

ACQ/INS

FURNISHED/INSTALLED NOTE:

VV- GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

VC- GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

CC- CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

HATCHED AREA NOT IN PROJECT SCOPE

PM&R

EXAM

ROOM

CORRIDOR

C498

PM&R

EXAM

ROOM

PM&R

EXAM

ROOM

PAIN PHARM

PAIN EXAM

PAIN SWAMP

PAIN

EXAM

ROOM

PAIN

EXAM

ROOM

OIT

PROCEDURE

ROOM

CLEAN

SUPPLY

PROCEDURE

ROOM

MSA

CHECKIN/OUT

PAIN BH

480479

PAIN &

PMR

VVC/TM

492A

EXISTING

ELEC.

PAIN

EXAM

ROOM

TOILET

EMG/SCI

PM&R

EXAM

ROOM

PM&R SWAMP

TOILET

SOILED

HOLDING

NURSES

NURSE

NAVIGATOR

33 33 33 33

1-AE110B

5 1

1 21

18 1920

PM&R

EXAM

ROOM 1

1-AE110B7

CLEAN

SUPPLY

0' 1'

6" 3"

1'

Gr ap hi c S ca le

: 1 /2"

1'-

0"

0' 4"

8" 1'

2'

Gr ap hi c S ca le

: 3 /32

1'

-0

0'

8' Gr ap hi c S ca le : 1

/16

1' -0

0' 8'

4' Gr ap hi c S ca le

: 1 /8"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 1 /4"

1'-

0"

0' 2'

1' 4'

Gr ap hi c S ca le

: 3 /8"

1'-

0"

0' 2'

4' 1' Gr ap hi c S ca le : 1

/2"

1'- 0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 3 /4"

1'-

0"

0' 1'

2' 6"

Gr ap hi c S ca le

: 1

1' -0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

A/E:Consultant:

Spinklered

BI

M

VI

SN

- B eh av io ra l H ea lth C lin ic

R en ov at io n/

BH

C lin ic

R en ov at io n.

rv t

7/

/2

:5 2:

P

M

FOURTH FLOOR EQUIPMENT PLAN INTERIOR

ELEVATIONS

RCO EM

BID DOCUMENTS 589A4-19-103

1-AE110B

Columbia Harry S. Truman Memorial Veterans Hospital

Columbia, Missouri

5/13/2021 (ADDENDUM

#1 - 7.16.21)

Fully Sprinklered

1/2" = 1'-0"1 PM&R EXAM ROOM ELEVATION, TYP. EAST

1/2" = 1'-0"2 PM&R EXAM ROOM TYPICAL ELEVATION-NORTH

1/2" = 1'-0"3 PM&R EXAM ROOM TYPICAL ELEVATION-SOUTH

1/2" = 1'-0"5 PM&R EXAM ROOM TYPICAL ELEVATION-WEST

NOTE

NUMBER JSN# ITEM NAME ACQ/INS

1 F0205 CHAIR, SIDE WITH ARMS V/V

2 F0340 STOOL, SELF ADJUSTING V/V

3 M9066 TABLE, EXAM/TREATMENT, HI-LOW V/V

4 M3070 HAMPER, LINEN V/V

5 F2010 BASKET,WASTEPAPER,STEP ON V/V

6 F3200 CLOCK, BATTERY, 12" DIAMETER V/V

7 A5106 WASTE DISPOSAL UNIT, SHARPS W/GLOVE DISPENSER V/C

8 A5180 TRACK, CUBICLE, SURFACE MOUNTED, WITH CURTAIN. SEE SPEC SECTION 102123. C/C

9 M1620 HOLDER, CHART, PATIENT V/C

10 A5075 DISPENSER, SOAP, DISPOSABLE V/C

11 A5077 DISPENSER, HAND SANITIZER, HANDS FREE V/C

12 PT045 BASE CABINET, ADA SINK C/C

13 A5080 DISPENSER, PAPER TOWEL, SS SURFACE MOUNTED V/C

14 N/A COMPUTER DESK V/V

15 F2000 BASKET, WASTE PAPER, ROUND, METAL V/V

16 M1801 COMPUTER, MICROPROCESSING, W/FLAT PANEL MONITOR V/V

17 F0280 CHAIR, SWIVEL, LOW BACK V/V

18 M4200 OTOSCOPE/OPHTHALMOSCOPE, WALL MOUNTED V/C

19 A1132 RAIL ( WELCH ALLYN - BASIS OF DESIGN OR VA APPROVED EQUAL), ACCESSORY

MOUNTING, 48"

C/C

20 M4100 SPHYGMOMANOMETER, ANEROID, WALL MOUNTED V/V

21 A5145 HOOK, GARMENT, TRIPLE, SS, SURFACE MOUNTED V/V

22 CS140 SINK, SS, COMPARTMENT (SEE PLUMBING FIXTURE #P-528). C/C

23 A1012 TELEPHONE, WALL MOUNTED, 1 LINE V/V

24 P3100 LAVATORY, VITREOUS CHINA C/C

25 M8810 MAYO STAND V/V

26 F0355 FOOTSTOOL, STRAIGHT V/V

27 M4116 VITAL SIGNS MONITOR V/V

28 M4255 IV STAND V/V

29 F0420 5 DRAWER FILE CABINET V/V

30 M4665 STRETCHER, RECOVERY, SURGICAL…