About this file

This asbestos and lead inspection report documents testing conducted at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The inspection sampled materials associated with replacing the roof on Building 6's A-wing under project number 695-22-103. Asbestos was identified in the tar flashing on the brick chimney and walls at the roof level. Lead paint was found on window sashes, trim, and sills; wood soffits; exterior brick walls; and porch trim. The related federal contract opportunity is solicitation number 36C25222B0031 to replace the Building 6 A-wing roof for the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12.

View the file

Other files

File Type Posted
36C25222B0031 0008.docx DOCX document
S06 - 695-22-103 SOW Revised Oct 18 2022.pdf PDF
36C25222B0031 0007.docx DOCX document
S06 - Wage Determination effective 10.14.22.pdf PDF
S06 - Second Pre-Bid Site Visit Notes_695-22-103.pdf PDF
36C25222B0031 0006.docx DOCX document
S04 - Second Site-Visit Sign-In Roster_10.7.22.pdf PDF
S06 - Wage Determination effective 8.5.2022.pdf PDF
36C25222B0031 0005.docx DOCX document
S06 - 695-22-103 SOW Revised Oct 3rd 2022.pdf PDF
36C25222B0031 0004.docx DOCX document
S06 - Drawings AD101 _ AE101.pdf PDF
S06 - 00 01 10 - TABLE OF CONTENTS with spec sections.pdf PDF
36C25222B0031 0003.docx DOCX document
36C25222B0031 0002.docx DOCX document
S06 - 695-22-103 Site Visit roster 8.15.22.pdf PDF
36C25222B0031 0001.docx DOCX document
S02 - 6a - 695-22-103 DrawingsPart-3.pdf PDF
S02 - 6a - 695-22-103 DrawingsPart-1.pdf PDF
S02 - Wage Determination effective 7.15.22.pdf PDF
S02 - 6a - 695-22-103 DrawingsPart-4.pdf PDF
S02 - 6a - 695-22-103 DrawingsPart-2.pdf PDF
S02 - 695-22-103 Firestop_SoleSourceJustification_Executed.pdf PDF
36C25222B0031_2.docx DOCX document
S02 - 6a - 695-22-103 DrawingsPart-5.pdf PDF
S02 - 6b - 695-22-103 Specifications.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS & LEAD PAINT SAMPLING REPORT

for

CLEMENT J. ZABLOCKI VAMC

MILWAUKEE, WI

PROJECT:

BUILDING 6

REPLACE A-WING ROOF

PROJECT # 695-22-103

Assessment Date:

OCTOBER 13, 2021

CONSULTANT:

CASTLE HILL ASSOCIATES, LLC

1197 FARNSWORTH RD. – UNIT E

WATERVILLE, OH 43566

567-952-0212 www.CASTLEHILLASSOCIATES.com

ACCOMPANYING 36C25222B0031 0004

TABLE OF CONTENTS

• ASBESTOS & LEAD PAINT SAMPLING SUMMARY

• ABESTOS BULK SAMPLING DESCRIPTIONS AND LAB RESULTS

• LEAD XRF SAMPLING RESULTS

• PHOTOS OF LEAD PAINTED BUILDING COMPONENTS

• ASBESTOS LABORATORY REPORT

• ASBESTOS LABORATORY CERTIFICATIONS

• INSPECTOR CERTIFICATIONS

CLEMENT J. ZABLOCKI VA MEDICAL CENTER, MILWAUKEE, WI

BUILDING 6 REPLACE A-WING ROOF 695-22-103

OCTOBER 13, 2021

INSPECTION SUMMARY

On October 13, 2021, Brett Brumbaugh performed asbestos and lead-based paint XRF testing prior to the planned replacement of the roof on the West A-wing of Building 6 at the Clement J. Zablocki VAMC in Milwaukee, WI. Bulk samples were collected of suspect asbestos containing materials and XRF testing was conducted of all painted surfaces associated with the work areas. There were 12 asbestos bulk samples collected and 8 XRF readings taken as part of this survey.

Asbestos bulk sampling as part of this project was based upon the appearance, texture, and location of the suspect materials. All bulk samples were analyzed utilizing current EPA methods for PLM (Polarized Light Microscopy) by EMSL Analytical in Plymouth, MI. EMSL is accredited by the NIST, NVLAP program (National Institute of Standards and Technology, National Voluntary Laboratory Accreditation Program) and also an American Industrial Hygiene Association (AIHA) accredited laboratory.

Lead paint testing was conducted on all painted surfaces in the work area using a Viken Detection Pb200i direct read XRF analyzer. Painted components that were tested in the areas are considered to be “lead-based” paint as defined by the US EPA (greater than 1.0 mg/cm2).

The inspection was conducted and the report was prepared by Brett Brumbaugh who is licensed by the State of Wisconsin as an Asbestos Inspector and is also an EPA Licensed Lead Risk Assessor. Mr. Brumbaugh has been conducting asbestos surveys and lead sampling since 1987, and is licensed in 28 states. He is also a Registered Environmental Property Assessor (REPA) and Certified Environmental Safety Compliance Officer (CESCO) through the NREP (National Registry of Environmental Professionals).

INSPECTION FINDINGS

Asbestos: As a result of the inspection and bulk sampling, there were asbestos identified in the roofing asphalt/tar flashing on the brick and upper walls of the roof.

Lead paint: As a result of the XRF testing for lead in paint, there was lead-paint identified on the following building components:

Lead painted components Locations

Window sashes, trim, and sills All windows in A-wing

Wood Soffits A-wing wood soffits/trim

Exterior brick wall Exterior walls of A-wing

Porch trim Trim on porch of A-wing

Inspector Signature:

Brett Brumbaugh, REPA, CESCO Certified Asbestos Inspector, State of Wisconsin License # AII-272513 Lead Risk Assessor – EPA License # LBP-R-I216003-1

ASBESTOS SAMPLING PROTOCOL

The bulk samples were collected from locations that were selected to be representative of the building materials. Sampling was accomplished using the simplified sampling scheme referenced in the AHERA regulations and found in the “Pink Book”. Locations of individual samples are referenced on this report.

The samples were either collected with a coring tool designed for asbestos sampling or placed into a plastic bag for laboratory analysis. The samples were analyzed via polarized light microscopy with dispersion staining, using the “Interim method for the Determination of Asbestos in Bulk Insulation Samples” found in Appendix A to Subpart F in 40 CFR Part 763.

The regulations require specific numbers of samples be obtained per homogeneous area. For example, when sampling for joint compound or asbestos in hard plaster (sprayed-on or troweled-on surfacing materials) samples are to be taken based on the following increments: 0 to 1000 square feet of material, 3 samples are necessary. From 1001 to 5000 square feet, 5 samples are necessary, over 5000 square feet 7 samples are required. If during analysis any samples are found to contain asbestos, the entire homogeneous area is delineated as asbestos containing material. In the case of pipe insulation or other types of manufactured materials, the regulations require only enough samples to ascertain whether asbestos is present. In this case, the minimum number of samples to collect and analyze is usually three. The sampling performed in this inspection followed these sampling guidelines.

ASBESTOS GLOSSARY OF TERMS

Friable asbestos material: means any material containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763 section 1, Polarized Light Microscopy, that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Category I Non-friable Asbestos Containing Material (ACM) means asbestos containing packings, gaskets, resilient floor coverings, and asphalt roofing products containing more that 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763, Section 1, Polarized Light Microscopy.

Category II Non-friable ACM means any material, excluding Category I non-friable ACM, containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized Light Microscopy that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Regulated Asbestos Containing Material (RACM): means (a) Friable asbestos material, (b) Category I non-friable ACM that has become friable, (c) category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material expected in the course of demolition or renovation operations regulated by this subpart.

ASBESTOS BULK SAMPLE DESCRIPTIONS & RESULTS

Facility: Clement J. Zablocki VAMC – Milwaukee, WI Building: Building 6 Area: A-Wing Roof Sampling Date: October 13, 2021 Analysis Date: October 19, 2021 Laboratory: EMSL Analytical, Inc. – Plymouth, MI Accreditation: NVLAP Asbestos Bulk Accredited Laboratory Sampler: Brett Brumbaugh

SAMPLE

# MATERIAL DESCRIPTION SAMPLE LOCATION

LABORATORY ANALYSIS

RESULT

Upper layer dimensional roofing shingles (black/gray)

A-wing N. roof area No Asbestos Detected

Upper layer dimensional roofing shingles (black/gray)

A-wing W. roof area No Asbestos Detected

Upper layer dimensional roofing shingles (black/gray)

A-wing S. roof area No Asbestos Detected

4 Lower layer 3-tab roofing shingles (black) A-wing N. roof area No Asbestos Detected

5 Lower layer 3-tab roofing shingles (black) A-wing W. roof area No Asbestos Detected

6 Lower layer 3-tab roofing shingles (black) A-wing S. roof area No Asbestos Detected

7 Roofing tar paper A-wing N. roof area No Asbestos Detected

8 Roofing tar paper A-wing W. roof area No Asbestos Detected

9 Roofing tar paper A-wing S. roof area No Asbestos Detected

10 Tar/asphalt on brick chimney A-wing N. chimney 28% Chrysotile Asbestos

11 Tar/asphalt on brick wall A-wing W. chimney 25% Chrysotile Asbestos

12 Tar/asphalt on wood wall on roof level A-wing Middle wall area 50% Chrysotile Asbestos

Note: Asbestos containing materials are defined by containing greater than 1% asbestos.

PHOTOGRAPHS OF ASBESTOS MATERIALS

Photo A-1 Tar coating on roof chimney

Photo A-2

Tar coating on roof chimney

Photo A-3 Tar coating on roof upper walls

PHOTOGRAPHS OF LEAD COMPONENTS

Photo L-1 Soffit and upper roof trim

Photo L-2

Wood soffits & trim

Photo L-3 Wood soffits & trim

Photo L-4

Exterior brick walls and porch trim

PHOTOGRAPHS OF LEAD COMPONENTS

Photo L-5

Photo L-6 Wood windows

Photo L-7

Photo L-8

Exterior wood siding and soffit trim

ASBESTOS LABORATORY REPORT

EMSL ANALYTICAL, INC.

EMSL Analytical, Inc.

15111 Northville Rd Plymouth, MI 48170

Tel/Fax: (734) 668-6810 / (734) 668-8532 http://www.EMSL.com / annarborlab@emsl.com

082102637EMSL Order:

Customer ID: CHAS42

Customer PO:

Project ID:

Attention: Phone:Brett Brumbaugh (567) 952-0212

Fax:Castle Hill Associates, LLC

Received Date:218-A Mechanic St. 10/15/2021 3:45 PM

Analysis Date:Waterville, OH 43566 10/19/2021

Collected Date:

Project: Zablocki VAMC - Bldg. 6

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

082102637-0001

None DetectedNon-fibrous (Other)92%Cellulose

Glass

2%

6%

Gray/Black

Fibrous

Heterogeneous

Shingle

082102637-0002

None DetectedQuartz

Non-fibrous (Other)

3%

90%

Cellulose

Glass

<1%

7%

Gray/Black

Fibrous

Heterogeneous

Shingle

082102637-0003

None DetectedNon-fibrous (Other)90%Glass10%Gray/Black

Fibrous

Heterogeneous

Shingle

082102637-0004

None DetectedQuartz

Non-fibrous (Other)

4%

88%

Glass8%Gray/Black

Fibrous

Homogeneous

Shingle

082102637-0004A

None DetectedNon-fibrous (Other)97%Cellulose3%Black

Non-Fibrous

Homogeneous

Tar

082102637-0005

None DetectedQuartz

Non-fibrous (Other)

3%

91%

Glass6%Gray/Black

Fibrous

Heterogeneous

Shingle

082102637-0005A

None DetectedNon-fibrous (Other)98%Cellulose2%Black

Non-Fibrous

Homogeneous

Tar

082102637-0006

None DetectedNon-fibrous (Other)92%Glass8%Gray/Black

Fibrous

Heterogeneous

Shingle

082102637-0007

None DetectedNon-fibrous (Other)22%Cellulose

Glass

75%

3%

Black

Fibrous

Homogeneous

Tar Paper

082102637-0008

None DetectedNon-fibrous (Other)23%Cellulose

Glass

75%

2%

Black

Fibrous

Homogeneous

Tar Paper

082102637-0009

None DetectedNon-fibrous (Other)30%Cellulose70%Black

Fibrous

Homogeneous

Tar Paper

082102637-0010

25% ChrysotileNon-fibrous (Other)70%Cellulose5%Black

Fibrous

Heterogeneous

Flashing

082102637-0011

28% ChrysotileNon-fibrous (Other)68%Cellulose4%Black

Fibrous

Heterogeneous

Flashing

082102637-0012

50% ChrysotileNon-fibrous (Other)40%Cellulose10%Brown/Black

Fibrous

Homogeneous

Tar Paper

082102637-0012A

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Tar

Initial report from: 10/19/2021 11:43:13

Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 10/19/2021 11:43 AM

EMSL Analytical, Inc.

15111 Northville Rd Plymouth, MI 48170

Tel/Fax: (734) 668-6810 / (734) 668-8532 http://www.EMSL.com / annarborlab@emsl.com

082102637EMSL Order:

Customer ID: CHAS42

Customer PO:

Project ID:

Analyst(s)

Ashton Bullock (10)

Ryan Shannon (5)

Ryan Shannon, Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Plymouth, MI NVLAP Lab Code 101048-4

Initial report from: 10/19/2021 11:43:13

Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 10/19/2021 11:43 AM

OrderID: 082102637

LEAD XRF TESTING DATA

LABORATORY CERTIFICATIONS

INSPECTOR CERTIFICATIONS

695-22-103_100% Basis of Design Report copy 58
695-22-103_100% Basis of Design Report copy 59
695-22-103_100% Basis of Design Report copy 60
695-22-103_100% Basis of Design Report copy 61
695-22-103_100% Basis of Design Report copy 62
695-22-103_100% Basis of Design Report copy 63
695-22-103_100% Basis of Design Report copy 64
695-22-103_100% Basis of Design Report copy 65
695-22-103_100% Basis of Design Report copy 66
695-22-103_100% Basis of Design Report copy 67
695-22-103_100% Basis of Design Report copy 68
695-22-103_100% Basis of Design Report copy 69
695-22-103_100% Basis of Design Report copy 70
695-22-103_100% Basis of Design Report copy 71
695-22-103_100% Basis of Design Report copy 72
695-22-103_100% Basis of Design Report copy 73
695-22-103_100% Basis of Design Report copy 74
695-22-103_100% Basis of Design Report copy 75
695-22-103_100% Basis of Design Report copy 76
695-22-103_100% Basis of Design Report copy 77
695-22-103_100% Basis of Design Report copy 78

File details come from the government source that posted it. Updated .