Testing Block-7.1-7.6-10-07-2026.xlsx
XLSX spreadsheet 11 KB Posted
- Solicitation number
- 36C25027Q0009
About this file
This file is a testing and device location specification document for fire alarm system maintenance at the Richard L. Roudebush VA Medical Center. The document details specific work items across multiple buildings and locations, identifying fire detection and alarm devices requiring testing and maintenance in compliance with NFPA 72-2025 standards.
The scope encompasses testing requirements for fire alarm components distributed across the RLR Campus, including smoke detectors, pull stations, speaker/strobes, heat detectors, strobes, control panels, tamper switches, waterflow switches, door holders, dual monitoring monitors, duct detectors, monitoring modules with relays, and supervisory devices. Testing locations include Building sections 5, 6, 19, and 23, plus a New Building 5 and Vivarium. The New Building 5 contains the most extensive device inventory with 76 total devices, including 1 control panel, 3 tamper switches, 1 waterflow switch, 26 speaker/strobes, 7 strobes, 1 ceiling strobe, 10 smoke detectors, 10 pull stations, 2 door holders, 3 dual monitoring monitors, 2 duct detectors, and 1 monitoring module. All devices are referenced against specific NFPA 72-2025 table requirements (primarily Tables 14.4.3.2 with corresponding device categories). The site visit for inspection is scheduled for October 7, 2026, at 10:00 AM EDT at Building 5, with quotes due October 21, 2026, at 10:00 AM EDT.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25027Q0009 0003.docx | DOCX document | |
| Testing Block 7.8-10-07-2026.xlsx | XLSX spreadsheet | |
| Site visit sign in 10.7.2026.pdf | ||
| 36C25027Q0009 0002.docx | DOCX document | |
| Table 7.1.3 example only.xlsx | XLSX spreadsheet | |
| Testing Block-One-10-07-2026.xlsx | XLSX spreadsheet | |
| RFI Response-10-15-2026.docx | DOCX document | |
| ATTACHMENT II - Instructions for VAAR 852.219-75 UPDATED.docx | DOCX document | |
| RFI Form.docx | DOCX document | |
| 36C25027Q0009 0001.docx | DOCX document | |
| 36C25027Q0009.docx | DOCX document | |
| ATTACHMENT II - Instructions for VAAR 852.219-75.docx | DOCX document | |
| ATTACHMENT I - SCA.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| 7.0 - SPECIFIC WORK ITEMS SUMMARY & LOCATION PAGE | ||||||
| RLR Campus | ||||||
| 7.1 - 7.7 Device location and quantities | ||||||
| Building | Section | Devices Type | Testing Requirements | Location | # of | |
| EOC | NFPA | Table | Devices | |||
| 5 | 7.2.1 | Smoke Detectors | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.2.1 | 2 |
| 5 | 7.2.2 | Speaker/Strobe | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.2.1 | 1 |
| 6 | 7.3.1 | Smoke Detectors | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.3.1 | 3 |
| 6 | 7.3.2 | Pull Stations | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.3.2 | 3 |
| 6 | 7.3.3 | Speaker/Strobe | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.3.3 | 2 |
| 19 | 7.4.1 | Smoke Detectors | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.4.1 | 2 |
| 19 | 7.4.2 | Pull Stations | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.4.2 | 2 |
| 19 | 7.4.3 | Heat Detectors | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.4.3 | 3 |
| 19 | 7.4.4 | Speaker/Strobe | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.4.4 | 4 |
| 19 | 7.4.5 | Strobe | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.4.5 | 2 |
| 23 | 7.5.1 | Pull Stations | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.5.1 | 2 |
| 23 | 7.5.2 | Smoke Detectors | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.5.2 | 2 |
| New Bldg 5 | 7.6.1 | Control Panel | 02.03.05 EP 05 | 72, 2025, Table 14.4.3.2 (4) | 7.6.1 | 1 |
| New Bldg 5 | 7.6.2 | Tamper Switches | 02.03.05 EP 02 | 72-2025 Table 14.4.3.2 (17)(10)(a) & (17)(11) | 7.6.2 | 3 |
| New Bldg 5 | 7.6.3 | Waterflow Switches | 02.03.05 EP 02 | 72-2025 Table 14.4.3.2 (17)(10)(a) & (17)(11) | 7.6.3 | 1 |
| New Bldg 5 | 7.6.4 | Speaker/Strobes | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.6.4 | 26 |
| New Bldg 5 | 7.6.5 | Ceiling Strobes | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.6.5 | 1 |
| New Bldg 5 | 7.6.6 | Strobes | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.6.6 | 7 |
| New Bldg 5 | 7.6.7 | Smoke Detectors | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.6.7 | 10 |
| New Bldg 5 | 7.6.8 | Pull Stations | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.6.8 | 10 |
| New Bldg 5 | 7.6.9 | Door Holders | 02.03.05 EP 04 | 72, 2025, Table 14.4.3.2 (22) | 7.6.9 | 2 |
| New Bldg 5 | 7.6.10 | Dual Monitoring Monitors | 02.03.05 EP 05 | 72, 2025, Table 14.4.3.2 (4) | 7.6.10 | 3 |
| New Bldg 5 | 7.6.11 | Duct Detectors | 02.03.05 EP 03 | 72, 2025, Table 14.4.3.2 (17) | 7.6.11 | 2 |
| New Bldg 5 | 7.6.12 | Monitoring Module with relay | 02.03.05 EP 05 | 72, 2025, Table 14.4.3.2 (4) | 7.6.12 | 1 |
| Vivarium | 7.7.1 | Supervisory Devices | 02.03.05 EP 05 | 72, 2025, Table 14.4.3.2 (4) | 7.7.1 | 1 |
| Vivarium | 7.7.2 | Smoke Detectors | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.7.2 | 5 |
| Vivarium | 7.7.3 | Pull Stations | 02.03.05 EP 03 | 72-2025, Table 14.4.3.2 (17) | 7.7.3 | 2 |
| Vivarium | 7.7.4 | Strobes | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.7.4 | 3 |
| Vivarium | 7.7.5 | Horn/Strobe | 02.03.05 EP 04 | 72-2025, Table 14.4.3.2 (22) | 7.7.5 | 2 |