Table 7.1.3 example only.xlsx
XLSX spreadsheet 16 KB Posted
- Solicitation number
- 36C25027Q0009
About this file
This is a technical specifications attachment providing a detailed inventory table of heat detection devices requiring inspection and maintenance at the Richard L. Roudebush VA Medical Center. The table documents 34 heat detectors distributed across multiple floors and locations throughout Building One, including basement levels, second floor, ninth floor, and eleventh floor spaces. Each device is cataloged with its specific location (such as elevator shafts, mechanical rooms, MRI suite, chaplain's office, and generator rooms), assigned scan ID number, and corresponding address code for tracking and identification purposes. All devices are specified to be tested in conformance with NFPA standards and Joint Commission recommendations as part of the fire alarm maintenance service contract (Solicitation Number 36C25027Q0009).
The fire alarm maintenance service contract is a VA requirement for inspection, maintenance, and minor repairs to electrical and mechanical portions of fire alarm and suppression systems at the Roudebush VAMC main hospital building, several outbuildings, and the Cold Springs Road remote site. A mandatory site visit is scheduled for October 7th, 2026 at 10:00 AM EDT at Building 5. Prospective contractors must submit Requests for Information (RFI) by October 14th, 2026 at 10:00 AM EDT to the contract specialist Stacie Hill at stacie.hill@va.gov, with all questions answered via amendment posted to sam.gov. Contract quotes are due October 21st, 2026 at 10:00 AM EDT and must include completion of ATTACHMENT II per VAAR 852.219-75 instructions. The contract is structured as a base year plus four-year option period (Base + Four).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25027Q0009 0003.docx | DOCX document | |
| Testing Block-7.1-7.6-10-07-2026.xlsx | XLSX spreadsheet | |
| Testing Block-One-10-07-2026.xlsx | XLSX spreadsheet | |
| RFI Response-10-15-2026.docx | DOCX document | |
| Testing Block 7.8-10-07-2026.xlsx | XLSX spreadsheet | |
| Site visit sign in 10.7.2026.pdf | ||
| 36C25027Q0009 0002.docx | DOCX document | |
| ATTACHMENT II - Instructions for VAAR 852.219-75 UPDATED.docx | DOCX document | |
| RFI Form.docx | DOCX document | |
| 36C25027Q0009 0001.docx | DOCX document | |
| ATTACHMENT II - Instructions for VAAR 852.219-75.docx | DOCX document | |
| ATTACHMENT I - SCA.pdf | ||
| 36C25027Q0009.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| TABLE 7.1.3 | ||||
| HEAT DETECTORS BY LOCATION IN BUILDING ONE | ||||
| All devices shall be tested in conformance with NFPA and Joint Commission | ||||
| recommendations as previously indicated | ||||
| Number of devices to be tested=34 | ||||
| Device Type | Floor | Location | Scan ID | Address |
| Heat Detector | BSMT | A-WING SERVICE ELEV. SHAFT HEAT | 208963230 | 1-0-1-32 |
| Heat Detector | BSMT | A-WING N. PASS. ELEV. SHAFT HEAT | 208963229 | 1-0-1-31 |
| Heat Detector | BSMT | A-WING S. PASS. ELEV. SHAFT HEAT | 208963228 | 1-0-1-30 |
| Heat Detector | BSMT | C-WING N. E. GEN. RM. HEAT | 208963879 | 5-0-104-54 |
| Heat Detector | BSMT | C-WING N. E. GEN. RM. HEAT | 208963878 | 5-0-104-53 |
| Heat Detector | BSMT | A-WING BY RM. A- B082 STERILE RM. DOOR | 208963255 | 1-0-1-59 |
| Heat Detector | BSMT | A-WING S. DOCK ROLL DOWN DOOR | 208963254 | 1-0-1-58 |
| Heat Detector | BSMT | B-WING MRI SUITE | 208963249 | 1-0-1-52 |
| Heat Detector | BSMT | B-WING MRI SUITE | 208963248 | 1-0-1-50 |
| Heat Detector | BSMT | B-WING MRI SUITE | 208963247 | 1-0-1-49 |
| Heat Detector | 2ND FLR | PARKING GARAGE SHAFT | 208963478 | 3-0-29-41 |
| Heat Detector | 2ND FLR | C-WING CHAPLAINS OFFICE | 208964236 | 6-0-129-7 |
| Heat Detector | 2ND FLR | C-WING CHAPLAINS OFFICE | 208964235 | 6-0-129-6 |
| Heat Detector | 9TH FLR | A-WING ELEV PENTHOUSE S. E. (ELEV. 13) | 208963723 | 5-0-79-51 |
| Heat Detector | 9TH FLR | A-WING ELEV PENTHOUSE S. E. | 208963730 | 5-0-79-58 |
| Heat Detector | 9TH FLR | A-WING ELEV PENTHOUSE HEAT | 208963711 | 5-0-79-34 |
| Heat Detector | 9TH FLR | A-WING ELEV PENTHOUSE S. E. | 208963729 | 5-0-79-57 |
| Heat Detector | 9TH FLR | A-WING ELEV PENTHOUSE S. HEAT | 208963710 | 5-0-79-33 |
| Heat Detector | 9TH FLR | A-WING ELEV PENTHOUSE CENTER HEAT | 208963707 | 5-0-79-30 |
| Heat Detector | 9TH FLR | A-WING ELEV PENTHOUSE S. E. | 208963728 | 5-0-79-56 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM MAIN RECALL | 208964777 | 1-0-191-137 |
| Heat Detector | 11TH FLR | SECONDARY RM P6 | 208964763 | 8-0-191-75 |
| Heat Detector | 11TH FLR | SECONDARY RM P5 | 208964762 | 8-0-191-74 |
| Heat Detector | 11TH FLR | SECONDARY RM P4 | 208964761 | 8-0-191-73 |
| Heat Detector | 11TH FLR | SECONDARY RM P3 | 208964760 | 8-0-191-72 |
| Heat Detector | 11TH FLR | SECONDARY RM P2 | 208964759 | 8-0-191-71 |
| Heat Detector | 11TH FLR | SECONDARY RM P1 | 208964758 | 8-0-191-70 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM. | 208964776 | 8-0-191-136 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM. | 208964775 | 8-0-191-133 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM. | 208964774 | 8-0-191-132 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM. | 208964765 | 8-0-191-123 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM. | 208964771 | 8-0-191-129 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM. | 208964770 | 8-0-191-128 |
| Heat Detector | 11TH FLR | ELEV. MECH. RM. | 208964768 | 8-0-191-126 |
7.1.3
File details come from the government source that posted it. Updated .