07.08_AC146 - SIXTH FLOOR REFLECTED CEILING PLAN.pdf

PDF 758 KB Posted

Attached to
Z1DA--Project # 539-21-111 - Upgrade Terminal Units Additional information available on page # 2.
Solicitation number
36C25021B0125
Issued by

About this file

This document contains a reflected ceiling plan drawing and specifications for an upgrade project at the Cincinnati VA Medical Center, as well as information on a related federal contract opportunity.

The reflected ceiling plan drawing provides the layout and design of the sixth floor ceiling, including all room names and numbers, ceiling heights, light locations, and other ceiling details. It specifies removing and replacing the existing acoustical ceiling tile and grid with new 24"x24" tile and grid to match the previous ceiling height.

The federal contract opportunity is solicitation number 36C25021B0125 for project number 539-21-111 to upgrade terminal units at the Cincinnati VA Medical Center. The opportunity is a solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10. No other details are provided on the required products or services, response dates, or award information.

View the file

Other files

File Type Posted
36C25021B0125 0005.docx DOCX document
Attachment II - Amendment No. 5.pdf PDF
Attachment I - Combine Specification Air Terminal Units.pdf PDF
13.54_M700 - MECHANICAL CONTROLS.pdf PDF
JA - DDCASC.pdf PDF
07.03_AC141 - FIRST FLOOR REFLECTED CEILING PLAN.pdf PDF
13.53_M602 - MECHANICAL SCHEDULES.pdf PDF
07.06_AC144 - FOURTH FLOOR REFLECTED CEILING PLAN.pdf PDF
07.04_AC142 - SECOND FLOOR REFLECTED CEILING PLAN.pdf PDF
36C25021B0125 0004.docx DOCX document
07.05_AC143 - THIRD FLOOR REFLECTED CEILING PLAN.pdf PDF
Appendix B - Hazardous Material Report.pdf PDF
07.07_AC145 - FIFTH FLOOR REFLECTED CEILING PLAN.pdf PDF
QA.pdf PDF
Specs.pdf PDF
07.09_AC147 - SEVENTH FLOOR REFLECTED CEILING PLAN.pdf PDF
36C25021B0125 0003.docx DOCX document
36C25021B0125 0002.docx DOCX document
36C25021B0125 0001.docx DOCX document
Attachment II - MD105B - FIFTH FLOOR DEMOLITION PLAN - AREA B.pdf PDF
Attachment III - MH105B - FIFTH FLOOR HVAC PLAN - AREA B.pdf PDF
Attachment I - Q and A.pdf PDF
Attachment I - Drawings.pdf PDF
Attachment III - DBA WD.pdf PDF
IFB - 36C25021B0125.pdf PDF
Attachment II - Specifications.pdf PDF
36C25021B0125_1.docx DOCX document
Attachment IV - EMR Form.pdf PDF
Attachment VI - J_A x2.pdf PDF
Attachment V - RFI Form.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Nurse Station

A600 Nurse Man.

A601

Staff Tlt.

A602

Conf. Rm.

A603

D.R.

A604

Storage A605

HAC

A606

S.R. (Neg.

Pres.)

A607

CL. Supp.

A608

S.R.

A609

D.R.

A610

D.R.

A611

S.R.

A612

Clinical Pat.

Support A613

S.R. (Neg.

Pres.)

A614

Elec.

A615

Soiled Utility A616

Elec.

A617

CL. Lin.

A618

D.R.

A619

S.R.

A620

S.R. (Neg.

Pres.)

A621

D.R.

A622

D.R.

A623

S.R. (Neg.

Pres.)

A624

CL. Supp.

A625

D.R.

A626

Stair 2 S*6*2

Oxygen Storage

A628 D.R.

A629

Nourish.

A630

D.R.

A631

Service Lobby A632

Elec.

A632E

Medical Conf.

A634B

Tlt.

A635

Phys.

Work Rm.

A632D

LKRS.

A637B

HAC

A637A

DB. Wtr.

A639

Research Pulmonary

Lab.

A640

HHN Off.

A641

Chief Medical

Res.

A642

Waiting Room A643

Stair 1 S*6*1

Elec.

A645

Equip. Stor.

A646

D.R.

A647

Nourish.

A648

D.R.

A649

Stair 5 S*6*5

D.R.

A651

Cl. Supp.

A652

Nurse Station

A653

S.R. (Neg.

Pres.)

A654 D.R.

A655

D.R.

A656

S.R. (Neg.

Pres.)

A657

D.R.

A658D.R.

A659

Elec.

A660

Elec.

A661

Soil. Util.

A662

S.R. (Neg.

Pres.)

A663

Nurse Man.

A664

Tlt.

A659A

Tlt.

A658A

S.R.

A667

D.R.

A668

D.R.

A669

S.R A670

Sterile Supplies

A671

S.R. (Neg.

Pres.)

A672

CL. Lin.

A673

HAC

A674Nurse

Conf. Rm.

A675

Office A676

Tlt.

A604A

Tlt.

A607A

Tlt.

A609A

Tlt.

A610A

Tlt.

A611A

Tlt.

A612A

Tlt.

A614A

Tlt.

A619A

Tlt.

A621A

Tlt.

A620A

Tlt.

A622A

Tlt.

A623A

Tlt.

A626A

Tlt.

A624A

Tlt.

A629A

Tlt.

A631A

Trash Chute A637

Medical Conf.

A634C

Meeting Room A634A

Sig. Clos.

A645A

Tlt.

A647A

Tlt.

A649A

Tlt.

A651A

Tlt.

A654A

Tlt.

A655A

Tlt.

A656A

Tlt.

A657A

Toilet A633A

Tlt.

A667A

Tlt.

A668A

Tlt.

A669A

Tlt.

A670A

Tlt.

A675A

Tlt.

A672A

Corridor C*6*3

Corridor C*6*1

Off.

B601

Elec.

B619B

Soiled B619A

Echo.

B604

Storage B605

IV Tech.

Off.

B606

Conf. Rm.

B607

Stair 3 S*6*3

Exam B609

Exam B610

Office B611A

Exam B612A

Exam B612B

Exam B612C

Exam B612D

Toilet B613

Exam B614

Toilet B615

Exam B616

Exam B617

Secretary B618

Elec.

B607A

Sig. Clos.

B606A

Tlt.

B605A

Tlt.

B603

Adm. Asst.

B620

Social Work Off.

B621 Phys.

B622

Conf.

Room B623

Chief Admn.

Asst.

B624

Chief Phys.

B625

Phys.

B626

Phys.

B627

Phys.

B628

Phys.

B629

Clos.

B625A

Corridor C*6*5

Stor.

B632

Stor.

B633

Ward Stor.

B635

Pulmonary Func. LAB

B636

HAC

B634

Corridor C*6*4

Tlt.

B620A

Corridor C*6*2

Corridor C*6*6

Exam B611B

Closet B609A

Storage A646A

Corridor C*6*1

Corridor C*6*1

Corridor C*6*1

7' - 10"

7' - 11"

7' - 11"

8' - 0"

8' - 0"

G E N E R A L C E I L I N G N O T E S

A. ALL CEILINGS SHALL BE EXISTING TO REMAIN UNLESS NOTED OTHERWISE.

B. ALL CEILING HEIGHTS SHOWN ON REFLECTED CEILING PLAN ARE PLUS-OR-MINUS (+/-).

CONTRACTOR SHALL DOCUMENT ALL EXISTING CEILING HEIGHTS PRIOR TO CONSTRUCTION

AND MATCH EXISTING HEIGHTS WITH NEW CEILINGS.

C. ANY ACOUSTICAL CEILING TILES THAT ARE DAMAGED DURING CONSTRUCTION SHALL BE

REPLACED.

D. ALL EXISTING LIGHTS SHALL REMAIN UNLESS NOTED OTHERWISE. SUPPORT DURING

REMOVAL OF CEILING AND REINSTALL IN THE SAME LOCATION.

E. SEE MECHANICAL DRAWINGS FOR MECHANICAL SCOPE.

F. CONTRACTOR SHALL TEMPORARILY SUPPORT ALL EXISTING CEILING ITEMS DURING CEILING

REPLACEMENT.

G. CONTRACTOR SHALL COORDINATE CEILING WORK WITH OTHER TRADES.

H. CONTRACTOR IS RESPONSIBLE FOR QUANTIFYING ALL CEILING DEVICES FOR REMOVAL AND

REINSTALLATION.

I. CONTRACTOR SHALL ASSUME THERMOSTATS ARE PLACED ON CLAY MASONRY TILE WALLS.

J. BUILDING 1 IS FULLY SPRINKLERED WITH AN AUTOMATIC WET PIPE FIRE PROTECTION

SYSTEM. CONTRACTOR SHALL PRESUME UP TO 15% OF THE SPRINKLER HEADS ON EACH

FLOOR IN THE SCOPE OF THIS PROJECT WITHIN THE AREA(S) OF WORK SHOWN WILL BE

REMOVED AND REPLACED TO AVOID CONFLICT WITH NEW CEILING GRID. NEW FIRE

SPRINKLER PIPING SHALL BE PROVIDED AS NECESSARY FOR SERVICE TO NEW SPRINKLER

HEADS. DESIGN, INSTALLATION, AND TESTING SHALL MEET THE REQUIREMENTS OF NFPA 13

LATEST EDITION, VA FIRE PROTECTION MANUAL, AND ALL STATE AND LOCAL CODES.

K. PLACEMENT OF EXISTING LIGHTING FIXTURES ARE INCLUDED ON THE ARCHITECTURAL RCP

SHEETS FOR GENERAL REFERENCE AND SHOULD NOT BE USED FOR REINSTALLATION

LOACATIONS OF THE FIXTURES. CONTRACTOR SHALL DOCUMENT LOCATION AND

ORIENTATION OF ALL CEILING-MOUNTED DEVICES /EQUIPMENT INCLUDING BUT NOT LIMITED

TO LIGHTING FIXTURES, CAMERAS, OCCUPANCY SENSORS, WAPS, SIGNAGE, ETC VIA DIGITAL

PHOTOGRAPHS PRIOR TO CEILING REMOVAL. PHOTOGRAPHS SHALL BE TAKEN TO INCLUDE

ADEQUATE BACKGROUND/CONTEXT INFORMATION FOR ACCURATE DEVICE/EQUIPMENT RE-

INSTALLATION, ORGANIZED ON A FLOOR-BY-FLOOR AND ROOM-BY-ROOM BASIS, AND BE

MADE AVAILABLE TO THE COR, ENGINEER, AND ALL TRADES UPON REQUEST.

D R A W I N G L E G E N D

T

THERMOSTAT. CONCEAL RACEWAY IN WALL TO THERMOSTAT LOCATION.

COORDINATE WITH MECHANICAL DRAWINGS. EXISTING CONCEALED

RACEWAYS ASSOCIATED WITH THERMOSTATS MAY BE RE-USED. REPAIR AND

PATCH WALL AS NECESSARY TO ACHIEVE FLUSH AND SMOOTH TRANSITION TO

ADJACENT WALL FACE. PAINT ENTIRE WALL TO MATCH ADJACENT WALL

FINISH.

2' X 2' ACCOUSTICAL TILE CEILING

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Cincinnati VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

UPGRADE TERMINAL

UNITS

C U s e rs

\c a rt e \D o c u m e n ts

\0

L o c a l R e v it F ile s \2

\F F

E C in c in n a ti

U p g ra d e

A T

U s

B c a rt e r.

d a n ie l0

.r v t

/1 /2

:5

:5

P M

AC146

SIXTH FLOOR REFLECTED

CEILING PLAN

08/31/2021 PQ CD

CINCINNATI, OH

539-21-111100% CONSTRUCTION

DOCUMENTS

1/16" = 1'-0"

SIXTH FLOOR REFLECTED CEILING PLAN

D R A W I N G N O T E S :

1 REMOVE AND REPLACE EXISTING ACOUSTICAL CEILING TILE AND GRID WITH NEW 24"X24" ACOUSTICAL CEILING

GRID AND TILES AT PREVIOUS CEILING HEIGHT.

1616637 EXPIRES 12/31/21

PATRICK R. QUINN

Revisions: Date:

AMENDMENT 2 10/20/2021

Sheets
AC146 - SIXTH FLOOR REFLECTED CEILING PLAN

File details come from the government source that posted it. Updated .