07.05_AC143 - THIRD FLOOR REFLECTED CEILING PLAN.pdf
PDF 1 MB Posted
- Attached to
- Z1DA--Project # 539-21-111 - Upgrade Terminal Units Additional information available on page # 2.
- Solicitation number
- 36C25021B0125
About this file
This document includes a reflected ceiling plan drawing and details for a federal construction project to upgrade terminal units. The drawing depicts the third floor plan of an existing facility, noting areas where the acoustic ceiling tile and grid will be removed and replaced. It also specifies the installation of access panels and indicates a space where work must be done within a HEPA cart and after hours to comply with infection control risk assessment guidelines.
The related federal contract opportunity is a solicitation to provide project number 539-21-111 for upgrading terminal units at an additional location, as referenced on page two. The solicitation does not include pricing terms, response dates, or other salient details. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
T
T
T T
T
T
T
T T
T
T
T T T
T
T
T
T
T
T
T
TT
T
T
T T T
T
Isolation Procedure
Rm.
C3024
Fluoro Procedure
Rm.
C3023
Corridor C*3*14
Procedure Rm.
C3021
Wash Room C3020
Physician Work Room
C3019
Clos.
C3018
Scope Storage
C3017
Ante Rm.
C3016
Scope Cleaning
C3016A
Procedure Rm.
C3025
Procedure Rm.
C3026
Prep/Recovery Rm.
C3027
Clean Supply C3014
Isolation Prep/Recovery
Rm.
C3013Prep/Recovery
Rm.
C3028
Prep/Recovery Rm.
C3029
Isolation Prep/Recovery
Rm.
C3012
Prep/Recovery Rm.
C3011 Prep/Recovery
Rm.
C3030
Prep/Recovery Rm.
C3010
Staff Break Rm.
C3009
Staff Toilet C3009A
Patient Toilet Rm.
C3008
Storage C3007A
Signal Clos.
C3035
Patient Toilet Rm.
C3037
Prep/Recovery Rm.
C3038
Prep/Recovery Rm.
C3039 Post-Op
C3040
Elec.
C3036A
Supplies / Equipment
C3006
Consult.
C3005
Corridor C*3*16
Corridor C*3*11
Lobby C3001
Waiting C3002
Staff Lounge
C326 Stair 10 S*3*10
Staff Work Rm.
C3007
SPD Case Cart
C3034
O.R. #7 C329
O.R.
Storage
C339
Anesthesia Work Rm.
C337
Men's Locker C324B
O.R. 1 C354
O.R. 2 C353
O.R.
Alcove
C352
O.R.
Alcove C352A
O.R.
Alcove C352BLight Rm.
C352C
O.R. 3 C351
O.R. 4 C350
Clean Core C340
Elec.
C338A
O.R. 5 C349
O.R. 6 C348
Mech.
C342
Corridor C*3*7
Women's Locker
C322
HAC
C346
Office C330
Cysto O.R.
C332
Cysto O.R.
C347
M. Shower C324A
W. Shower C322A
Sub-Waiting C3036
Work Rm.
C3004A
Nurse Station C3031
Sterile Core C347A
Frozen Section
C316
Utility C320
Office C318 Elec.
C335 Tele.
C333
Corridor C*3*9
Entry C324
A/C Shaft C337A
Soiled Utility C3032
Men's C3002A
Women's C3002B
Pat. Tlt.
C3022
Linen Clost.
C3015
Reception C3004
Office C317
Office C319
Office C321
Office C323
Office C325
Stair 6 S*3*6
Anesthesia Tech.
C328
Cleaning Supply C3016B
Temp.
Control C3005A
Oxygen Storage
C369
Vestibule C322B
Vestibule C324C
HAC
C3033
Patient Room 1
A387A
Patient Room A387B
Patient Room A387C
Patient Room A387D
Patient Room A387E
Patient Room A387F
Patient Room A387G
Shower A387H
Patient Room A387I
Patient Room A387J
Patient Room 10
A387K
Nurse Station
A387
Vasc. Lab A300
Vascular Lab A301
Chief Diet.
A302
Diet Sec.
A303
F. Tlt.
A306A
Exam A308
Exam A309
Storage A310
Lab A311
Machine A311A
Plaster A312
CAD/CAM
A313
Off.
A314
Elec.
A315
M. Tlt.
A316
Stor.
A317
HAC
A318
Asst. Chief A319
Pros. Adm.
Asst.
A320
Clos.
A320A
Chief Off.
A321
Ward Adm.
Off.
A323
Adm. Asst.
A324
Office A324A
Office A324B
Office A324C
Chief PBS A324D
Office A324E
Office A324G
Stor.
A324F
Stor.
A324H
Elec.
A331A
Pros. Stor.
A330
Pros. Off.
A332
Stair 2 S*3*2
Stor.
A335
Stor.
A336
Asst. Chief Diet.
A337
F. Tlt.
A341
M. Tlt.
A342
Stair 1 S*3*1
Stor.
A344
Sig.
A345
Stor.
A344A
Tlt.
A347A
Vasc. Lab A347
Elec.
A350
Mech.
A351
Adm. Asst.
A352
Off.
A353
Conf.
A354
Chief of Surgery
A355
Off.
A356
Off.
A357
Off.
A358
Off.
A359
Off.
A360
Off.
A361
Corridor C*3*3
Off.
A355A
Physician Review A355B
Linen Clos.
A389
Nurse Off.
A390
Soil Utility A391
Equip. Stor.
A392
HVAC
A394
Elec.
A395
Sig.
A396
Clean Supply
A397
Vasc. Lab A379
HAC
A378
HAC
A380
Lounge A382
Tlt.
A382A
M. Lock.
A382BFemale
Locker A382C
Soc. Wrk.
A383
Respiratory Therapy
A384
Conference Room A385
Pharm.
A386
On Call A381
Tlt.
A381A
Patient Advocate
A348
Off.
A349
Stair 5 S*3*5
Off.
A350B
Off.
A350D
Off.
A350A
Off.
A350C
Corridor C*3*1
Elect.
A346
Classroom B308
Nurse Educator
B309
Stor.
B310
Office B310A
Conf.
B310B
Off.
B311A
Off.
B311B
Asst. Ch.
B311E
Word Proc.
B311G
Off.
B312A
Sig.
B312B
Elec.
B312C
Stair 3 S*3*3
Nursing Conf.
B314
F. Tlt.
B315
Stor.
B316
Eq. Stor.
B317
Res. Stor.
B318
Stor.
B319
Classroom B320
Office B321
Off.
B319A
Off.
B319B
Off.
B319C
Off.
B319D
Stor.
B321A
Classroom B321B
Work Area B320A
Stor.
B320B
Stor.
B320C
HAC
B319E
Stair 4 S*3*4
Corridor C*3*5
Corridor C*3*4
Learning Exchange
B322
Work Area B322A
Work Area B322B
Elec.
B322C
Pat. Dining B325
Family Waiting
B326
Reception B327
Office C300
Consult C301
Break Rm.
C302
Patient Tlt.
C303
PACU
C304
Ophthamology Optometry
C305 Office C306
Acute Care C307
Storage C308
Corridor C*3*6
Patient Rm.
C304A
Patient Rm C304B
Patiet Rm C304C
Meds.
C304D
Clean Supp.
C304E
Patient Rm.
C304F
Patient Rm.
C304G
Patient Rm.
C304H
Patient Rm.
C304I
Patient Tlt.
C304J
Patient Rm.
C304K
Patient Rm.
C304L
Patient Rm.
C304M
Patient Rm.
C304N
Patient Rm.
C304O
EMS
C360Off.
C361
Clean Stretcher
Stor.
C355Anaesthetics
C356 Soil C357
Storage C358
HAC
C359
Electrical C309
Family Wtng.
C310
Tele C311
Lactation C312
Grieve Consult
C313
ICU Dir.
Off.
C314
Tlt.
C313B
Corridor C*3*17
Adm. Asst.
A307A
Stor.
A324I
Tlt.
A388
Stair 9 S*3*9
HAC
B301
Db. Wtr B302
Tlt.
C302A
Service Lobby A338
M. Locker A339
F. Locker A340
Corridor C*3*19
RO DI
Water A343
De-Gown A342
Gowning Rm.
A341
De-Con B303
Prep/Pack B307C
HAC
B303A
HAC
B307D
Office B305B
Office B305A
Storage B308A
Office B305C
Conf Rm.
B305D
Vendor Drop Off
B304 Cool Down
Cart B307B
Steam Equip Rm.
B307A
Open Office B305
Ante Rm/ Clean Exit
B307
Elec B306
Tr. Ch.
A338A
Stair 8 S*3*8
Elec A338B
O.R.
Alcove C352E
O.R.
Alcove
C334
Entry C322C
Stair 11 S*3*11
Corridor C*3*15
Corridor C*3*12
Corridor C*3*13
Corridor C*3*18
Mechanical A3002
Corridor C*3*1
Corridor C*3*1
Corridor C*3*1
Lounge B311C
Asst. Ch.
B311D
Adm. Off.
B311F
Off.
B311H
Chief Nurse B311I
Research Off.
B312
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
7' - 11"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
7' - 6"
8' - 0"
9' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"8' - 2"
8' - 4"
8' - 0"
8' - 0" 8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"8' - 4" 1
8' - 0"
8' - 0"
G E N E R A L C E I L I N G N O T E S
A. ALL CEILINGS SHALL BE EXISTING TO REMAIN UNLESS NOTED OTHERWISE.
B. ALL CEILING HEIGHTS SHOWN ON REFLECTED CEILING PLAN ARE PLUS-OR-MINUS (+/-).
CONTRACTOR SHALL DOCUMENT ALL EXISTING CEILING HEIGHTS PRIOR TO CONSTRUCTION
AND MATCH EXISTING HEIGHTS WITH NEW CEILINGS.
C. ANY ACOUSTICAL CEILING TILES THAT ARE DAMAGED DURING CONSTRUCTION SHALL BE
REPLACED.
D. ALL EXISTING LIGHTS SHALL REMAIN UNLESS NOTED OTHERWISE. SUPPORT DURING
REMOVAL OF CEILING AND REINSTALL IN THE SAME LOCATION.
E. SEE MECHANICAL DRAWINGS FOR MECHANICAL SCOPE.
F. CONTRACTOR SHALL TEMPORARILY SUPPORT ALL EXISTING CEILING ITEMS DURING CEILING
REPLACEMENT.
G. CONTRACTOR SHALL COORDINATE CEILING WORK WITH OTHER TRADES.
H. CONTRACTOR IS RESPONSIBLE FOR QUANTIFYING ALL CEILING DEVICES FOR REMOVAL AND
REINSTALLATION.
I. CONTRACTOR SHALL ASSUME THERMOSTATS ARE PLACED ON CLAY MASONRY TILE WALLS.
J. BUILDING 1 IS FULLY SPRINKLERED WITH AN AUTOMATIC WET PIPE FIRE PROTECTION
SYSTEM. CONTRACTOR SHALL PRESUME UP TO 15% OF THE SPRINKLER HEADS ON EACH
FLOOR IN THE SCOPE OF THIS PROJECT WITHIN THE AREA(S) OF WORK SHOWN WILL BE
REMOVED AND REPLACED TO AVOID CONFLICT WITH NEW CEILING GRID. NEW FIRE
SPRINKLER PIPING SHALL BE PROVIDED AS NECESSARY FOR SERVICE TO NEW SPRINKLER
HEADS. DESIGN, INSTALLATION, AND TESTING SHALL MEET THE REQUIREMENTS OF NFPA 13
LATEST EDITION, VA FIRE PROTECTION MANUAL, AND ALL STATE AND LOCAL CODES.
K. PLACEMENT OF EXISTING LIGHTING FIXTURES ARE INCLUDED ON THE ARCHITECTURAL RCP
SHEETS FOR GENERAL REFERENCE AND SHOULD NOT BE USED FOR REINSTALLATION
LOACATIONS OF THE FIXTURES. CONTRACTOR SHALL DOCUMENT LOCATION AND
ORIENTATION OF ALL CEILING-MOUNTED DEVICES /EQUIPMENT INCLUDING BUT NOT LIMITED
TO LIGHTING FIXTURES, CAMERAS, OCCUPANCY SENSORS, WAPS, SIGNAGE, ETC VIA DIGITAL
PHOTOGRAPHS PRIOR TO CEILING REMOVAL. PHOTOGRAPHS SHALL BE TAKEN TO INCLUDE
ADEQUATE BACKGROUND/CONTEXT INFORMATION FOR ACCURATE DEVICE/EQUIPMENT RE-
INSTALLATION, ORGANIZED ON A FLOOR-BY-FLOOR AND ROOM-BY-ROOM BASIS, AND BE
MADE AVAILABLE TO THE COR, ENGINEER, AND ALL TRADES UPON REQUEST.
D R A W I N G L E G E N D
T
THERMOSTAT. CONCEAL RACEWAY IN WALL TO THERMOSTAT LOCATION.
COORDINATE WITH MECHANICAL DRAWINGS. EXISTING CONCEALED
RACEWAYS ASSOCIATED WITH THERMOSTATS MAY BE RE-USED. REPAIR AND
PATCH WALL AS NECESSARY TO ACHIEVE FLUSH AND SMOOTH TRANSITION TO
ADJACENT WALL FACE. PAINT ENTIRE WALL TO MATCH ADJACENT WALL
FINISH.
2' X 2' ACCOUSTICAL TILE CEILING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Cincinnati VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FULLY SPRINKLERED
UPGRADE TERMINAL
UNITS
C U s e rs
\c a rt e \D o c u m e n ts
\0
L o c a l R e v it F ile s \2
\F F
E C in c in n a ti
U p g ra d e
A T
U s
B c a rt e r.
d a n ie l0
.r v t
/1 /2
:5
:3
P M
AC143
THIRD FLOOR REFLECTED
CEILING PLAN
08/31/2021 PQ CD
CINCINNATI, OH
539-21-111100% CONSTRUCTION
DOCUMENTS
1/16" = 1'-0"
THIRD FLOOR REFLECTED CEILING PLAN
D R A W I N G N O T E S :
1 REMOVE AND REPLACE EXISTING ACOUSTICAL CEILING TILE AND GRID WITH NEW 24"X24" ACOUSTICAL CEILING
GRID AND TILES AT PREVIOUS CEILING HEIGHT.
2 INSTALL 24" X 24" GYPSUM BOARD ACCESS PANELS AT LOCATIONS SHOWN. FOLLOW ICRA GUIDELINES IN SPS
SPACE. SUBMIT ICRA PLAN TO VA COR MINIMUM 3 WEEKS PRIOR TO WORK IN THIS AREA. ALL WORK IN THIS
SPACE SHALL BE WITHIN A HEPA CART AND WILL BE DURING OFF-BUSINESS HOURS.
1616637 EXPIRES 12/31/21
PATRICK R. QUINN
Revisions: Date:
AMENDMENT 2 10/20/2021
| Sheets |
| AC143 - THIRD FLOOR REFLECTED CEILING PLAN |
File details come from the government source that posted it. Updated .