07.07_AC145 - FIFTH FLOOR REFLECTED CEILING PLAN.pdf
PDF 742 KB Posted
- Attached to
- Z1DA--Project # 539-21-111 - Upgrade Terminal Units Additional information available on page # 2.
- Solicitation number
- 36C25021B0125
About this file
This document includes a reflected ceiling plan drawing and associated federal contract opportunity for upgrading terminal units. The reflected ceiling plan drawing depicts the fifth floor layout of the Cincinnati VA Medical Center and notes that existing 2' x 2' acoustical ceiling tiles and grid will be removed and replaced with new 24" x 24" acoustical ceiling grid and tiles at the previous ceiling height. The related federal contract opportunity is solicitation number 36C25021B0125 for Project #539-21-111 to upgrade terminal units at the Cincinnati VA Medical Center, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10. Additional unspecified information is available on page two of the solicitation.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T T
T
T T
T
T
T
T T
T T
T
Nourishment A508
Single Room A504
Nurse Station
A506
Family Lounge
A578
HUC
A581
Physical Therapy
A579
Consult A580
Staff Lounge
A510
Telem.
A509
Office A582
Meds A505
Staff Tlt A513
Corridor C-5-3
Bath A504B
Clean Supply
A503
D.R.
A501
D.R.
A502
S.R. Neg.
Pressure
A511
S.R. Neg.
Pressure
A512
Elec.
A514
Soil. Util.
A515
Elec.
A516
D.R.
A517
D.R.
A518
S.R.
A519
D.R.
A520
D.R.
A521
S.R.
A522
D.R.
A523
Storage A524
Clean Linen A525
D.R.
A526
D.R.
A527
Nurse Manager
A528
Bath A511A
Bath A512A
Bath A521A
Bath A520A
Bath A522A
Bath A519A
Bath A523A
Bath A518A
Bath A517A
Stair 2 S*5*2
Bath A526A
Bath A502A
Bath A501A
Tr. Ch.
A535
HAC
A535A
Service Lobby A536
Elec.
A537A
Work Room A537F
Stor A544
Stor A545A
HAC
A545
Bath A527A Exam
Room 5 A555
Clos.
A556
Exam Room 4
A557A
Surgery Office A557B
Procedure Room A557C
Procedure Room A557D
Exam A558
Waiting Area A559
Clerk A559A
Class Rm.
A564
Exam 7 A566
Exam 6 A567
Exam 5 A568
Exam 4 A569
Exam 3 A570
Exam 2 A571
Exam 1 A572
Staff Physician
A573
Office A574
Pgm. Supp.
Asst.
A575
Elec.
A560
Tele A561
Soil A562
HAC
A562A
Stor.
A563A
Pain Nurse A563
Stor.
A564A
Stor.
A565A
Supp Clos A567A
Tlt.
A570A
Tlt.
A573A
Corridor C*5*4
Telesurgery Office A554
Tlt.
A553
Skin and Wound
Care Clinic A551
Waiting Area A550
Toilet A577
Closet A551A
Stor.
A551B
Stair 5 S*5*5
Stair 1 S*5*1
Medical Service Office B537
Medical Service
B538
Office B539
Chief Office B540
Adm. Asst.
A540
Adm Asst.
A541
Chief Med.
Svc.
A542
Sig. Clos.
A546A
Work Rm.
A549
Dirty Equipment
A537B
Db. Wtr.
A539
Storage A537E
Clean Supply A537D
Oxygen Storage
Equipment Room A537C
Office B537A
Med Svc B501
Office B503
Office B504
Conferece Room B523
Cleric B524
Rolling Storage
B525
IV
Ante-Room
B526 IV Prep
B526A
IV Buff B526B
Closet B526C
Tlt.
B503A
Storage B506
Conference Rm.
B507
Office B508
Office B509
Office B510
Office B511
Office B512
Office B513
Office B514
Office B515
Office B516
Office B517
Storage B515A
Closet B507A
Dispensing Area B536
Office B535C
Stair 3 S*5*3
Storage B505H
Sig. Clos.
B505G
Office B518
Corridor C*5*5
Office B505
Tlt.
B505A
Elec.
B505B
HAC
B521E
Stor.
B518A
Staff Tlt.
B535B
Stor.
B521D
Elec.
B521B
Cart Stor.
B535
Narc. Vault B521A Chief
B522
Compound Picking
B527Unit Dose B535A
Corridor C*5*1
Closet A554A
Elec.
A546
Tlt.
A571A
Corridor C*5*2
Corridor C*5*3
8' - 2"
G E N E R A L C E I L I N G N O T E S
A. ALL CEILINGS SHALL BE EXISTING TO REMAIN UNLESS NOTED OTHERWISE.
B. ALL CEILING HEIGHTS SHOWN ON REFLECTED CEILING PLAN ARE PLUS-OR-MINUS (+/-).
CONTRACTOR SHALL DOCUMENT ALL EXISTING CEILING HEIGHTS PRIOR TO CONSTRUCTION
AND MATCH EXISTING HEIGHTS WITH NEW CEILINGS.
C. ANY ACOUSTICAL CEILING TILES THAT ARE DAMAGED DURING CONSTRUCTION SHALL BE
REPLACED.
D. ALL EXISTING LIGHTS SHALL REMAIN UNLESS NOTED OTHERWISE. SUPPORT DURING
REMOVAL OF CEILING AND REINSTALL IN THE SAME LOCATION.
E. SEE MECHANICAL DRAWINGS FOR MECHANICAL SCOPE.
F. CONTRACTOR SHALL TEMPORARILY SUPPORT ALL EXISTING CEILING ITEMS DURING CEILING
REPLACEMENT.
G. CONTRACTOR SHALL COORDINATE CEILING WORK WITH OTHER TRADES.
H. CONTRACTOR IS RESPONSIBLE FOR QUANTIFYING ALL CEILING DEVICES FOR REMOVAL AND
REINSTALLATION.
I. CONTRACTOR SHALL ASSUME THERMOSTATS ARE PLACED ON CLAY MASONRY TILE WALLS.
J. BUILDING 1 IS FULLY SPRINKLERED WITH AN AUTOMATIC WET PIPE FIRE PROTECTION
SYSTEM. CONTRACTOR SHALL PRESUME UP TO 15% OF THE SPRINKLER HEADS ON EACH
FLOOR IN THE SCOPE OF THIS PROJECT WITHIN THE AREA(S) OF WORK SHOWN WILL BE
REMOVED AND REPLACED TO AVOID CONFLICT WITH NEW CEILING GRID. NEW FIRE
SPRINKLER PIPING SHALL BE PROVIDED AS NECESSARY FOR SERVICE TO NEW SPRINKLER
HEADS. DESIGN, INSTALLATION, AND TESTING SHALL MEET THE REQUIREMENTS OF NFPA 13
LATEST EDITION, VA FIRE PROTECTION MANUAL, AND ALL STATE AND LOCAL CODES.
K. PLACEMENT OF EXISTING LIGHTING FIXTURES ARE INCLUDED ON THE ARCHITECTURAL RCP
SHEETS FOR GENERAL REFERENCE AND SHOULD NOT BE USED FOR REINSTALLATION
LOACATIONS OF THE FIXTURES. CONTRACTOR SHALL DOCUMENT LOCATION AND
ORIENTATION OF ALL CEILING-MOUNTED DEVICES /EQUIPMENT INCLUDING BUT NOT LIMITED
TO LIGHTING FIXTURES, CAMERAS, OCCUPANCY SENSORS, WAPS, SIGNAGE, ETC VIA DIGITAL
PHOTOGRAPHS PRIOR TO CEILING REMOVAL. PHOTOGRAPHS SHALL BE TAKEN TO INCLUDE
ADEQUATE BACKGROUND/CONTEXT INFORMATION FOR ACCURATE DEVICE/EQUIPMENT RE-
INSTALLATION, ORGANIZED ON A FLOOR-BY-FLOOR AND ROOM-BY-ROOM BASIS, AND BE
MADE AVAILABLE TO THE COR, ENGINEER, AND ALL TRADES UPON REQUEST.
D R A W I N G L E G E N D
T
THERMOSTAT. CONCEAL RACEWAY IN WALL TO THERMOSTAT LOCATION.
COORDINATE WITH MECHANICAL DRAWINGS. EXISTING CONCEALED
RACEWAYS ASSOCIATED WITH THERMOSTATS MAY BE RE-USED. REPAIR AND
PATCH WALL AS NECESSARY TO ACHIEVE FLUSH AND SMOOTH TRANSITION TO
ADJACENT WALL FACE. PAINT ENTIRE WALL TO MATCH ADJACENT WALL
FINISH.
2' X 2' ACCOUSTICAL TILE CEILING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Cincinnati VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FULLY SPRINKLERED
UPGRADE TERMINAL
UNITS
C U s e rs
\c a rt e \D o c u m e n ts
\0
L o c a l R e v it F ile s \2
\F F
E C in c in n a ti
U p g ra d e
A T
U s
B c a rt e r.
d a n ie l0
.r v t
/1 /2
:5
:5
P M
AC145
FIFTH FLOOR REFLECTED CEILING
PLAN
08/31/2021 PQ CD
CINCINNATI, OH
539-21-111100% CONSTRUCTION
DOCUMENTS
1/16" = 1'-0"
FIFTH FLOOR REFLECTED CEILING PLAN
D R A W I N G N O T E S :
1 REMOVE AND REPLACE EXISTING ACOUSTICAL CEILING TILE AND GRID WITH NEW 24"X24" ACOUSTICAL CEILING
GRID AND TILES AT PREVIOUS CEILING HEIGHT.
1616637 EXPIRES 12/31/21
PATRICK R. QUINN
Revisions: Date:
AMENDMENT 2 10/20/2021
| Sheets |
| AC145 - FIFTH FLOOR REFLECTED CEILING PLAN |
File details come from the government source that posted it. Updated .