36C25020B0028-003.pdf
PDF Posted
- Solicitation number
- 36C25020B0028
About this file
This pre-solicitation notice describes a requirement for renovation services at a Department of Veterans Affairs medical center. The contractor shall renovate approximately 17,000 square feet of ICU/TCU space at the Dayton VA Medical Center in Ohio, upgrading facilities and IT systems. The project duration is 365 calendar days from notice to proceed.
The solicitation will be issued on or around March 20, 2020 via FBO.gov, with proposals due approximately 30 days later. The estimated value is between $5-10 million. The NAICS code is 236220 and the small business size standard is $39.5 million. The solicitation will be 100% set aside for SDVOSBs, which must be registered and verified on various websites. The contractor must perform a minimum of 15% of construction work. Bid, payment and performance bonds will be required. A site visit will be scheduled. Questions may be emailed to the point of contact listed.
36C25020B0028 S02. Attachment 2 - Project Drawings - Arch Structural (1 of 2).pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25020B0028 0006.docx | DOCX document | |
| 36C25020B0028 0005.docx | DOCX document | |
| Site Visit sign-in.pdf | ||
| 20200702 Addendum 1.pdf | ||
| 20200701 TCUICU 2nd Floor Room Names.pdf | ||
| 20200701 TCUICU 2nd Floor RCP.pdf | ||
| PreBid RFIs Answers.pdf | ||
| 36C25020B0028 0004.docx | DOCX document | |
| Bid Opening Instructions.pdf | ||
| 36C25020B0028-0003000.docx | DOCX document | |
| 36C25020B0028-0002000.docx | DOCX document | |
| 36C25020B0028-0001000.docx | DOCX document | |
| 36C25020B0028-0001001.pdf | ||
| 36C25020B0028-004.pdf | ||
| 36C25020B0028-009.pdf | ||
| 36C25020B0028-007.pdf | ||
| 36C25020B0028-005.pdf | ||
| 36C25020B0028-008.pdf | ||
| 36C25020B0028-002.pdf | ||
| 36C25020B0028-006.pdf | ||
| 36C25020B0028-001.docx | DOCX document |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WISCONSIN
IOWA
CEMETERY
K A N S A S
CEMETERY
A V E
McMAHO N
CEMETERY
AVE.
KENTUCKY
C O L O R A D O
A V E
BROWN
IN
D
IA
N A
A V E
AV
E
MONUMENT
McMA
HON
AVE.
AVE.
I L L
IN
O
IS
A V E
AVE.
NEW
O H
IO
YORK
KENTUCKY
S O U T H
AVE.
P E N N S Y L V A N
IA
AVE.
A V E
O H
IO
WEST VIR
GIN
IA
AVE
AV
E
AVE.
A V E
G E T T Y S B U R G
A V E
WEST
THIR
D
ST
CEMETERY
MICHIGAN AVE
C O N N E C T
IC
U T A V E
M A
IN
E
A V E
DAKOTA AVE.
LAKE
LAKE-
V E R M O N T A V E
O R E G O N
A V E
E
A
B
C
D
118 400
CITY OF DAYTON
FIRE HOUSE NO. 17
131 26
34139
4100 WEST THIRD STREET
RETENTION
POND
U.S. ROUTE 35
NE
W
ME
XI
CO
P
LA
CE
U .S
. R O
U
TE 3
S E R
VI
C E R D
A V E
N HAMPSHIR
E
AVE.DELAWARE
DELAWARE
A V E
N
J E R S E Y
B R O W N
AVE.
CIRCLE
S E R V I C E
R D
R D
E
I C E
R V
S
R H O D E
IS
L A N D
A V E
MISSOURI AVEMICHIGAN AV
E
E
D R
R
C I V
S E
M
IN
N E S O T A
A V E
MASSACHUSETTS BLVD.
KENTUCKYAVE.
M A R Y L A N D
A V
E AVE.
WISCONSIN AVE.
TEN
N
ESSEE
P E N N S Y L V A N
IA
DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER
M
IN
N E S O T A
A V E
HAWAII
PLACE
TEXAS AVE.
Liscum Dr.
Secondary
Supply
AVE.
Dayton, Ohio 45428
EXTERIOR ELEVATION
INTERIOR ELEVATION
SEE 700 SERIES SHEETS
SECTION/DETAIL NUMBER
DRAWING NUMBER
EQUIPMENT TAG
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
SEE SHEET A001
CEILING HEIGHT
FINISH DESIGNATION
X
10'-8"
X
X
XX.X-X
X
X
1/A101
X
XXXX
X
SIM
XX
SIGNAGE TAG TOILET ACCESSORY TAGXX
DAYTON VAMC PROJECT LOCATION
LOADING DOCK
CONTRACTOR PARKING &
STORAGE CONTAINER
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G
IS
E T
R
ED RA
C H
TI
E C T
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Department of Veterans Affairs Medical Center
ARCHITECTURE PLANNING INTERIOR DESIGN
3131 NEWMARK DRIVE, SUITE 200
MIAMISBURG, OHIO 45342
937.461.3290 P
JOHN POE ARCHITECTS
HEAPY ENGINEERING
MECHANICAL ELECTRICAL TECHNOLOGY
1400 WEST DOROTHY LANE
DAYTON, OH 45409
937.224.0861 P
937.224.5777 F
THP LIMITED INC.
STRUCTURAL ENGINEER
100 E. EIGHTH STREET
CINCINNATI, OH 45202
513.241.3222 P
513.241.2981 F
Dwg. of
TERRACON CONSULTANTS
ENVIRONMENTAL ENGINEER
611 LUNKEN PARK DRIVE
CINCINNATI, OH 45226
513-321-5816 P
Renovate TCU-ICU Space Bldg. 330
03/09/2020
COVER SHEET
G001
MWTH
17005.00
552-18-102
Dayton Ohio
Renovate TCU-ICU Space Bldg. 330
4100 West Third Street Dayton, OH 45428 PROJECT #: 552-18-102
G001 COVER SHEET
G100 CODE DATA
G101 PHASING PLANS
S001 GENERAL NOTES
S100 FRAMING PLANS AND DETAILS
AD101 DEMOLITION PLANS
A101-D1 ENLARGED DIMENSION PLAN
A101-D2 ENLARGED DIMENSION PLAN
A101-D3 DIMENSION PLANS
A101-N NOTE PLANS
A121 REFLECTED CEILING PLAN
A401 ENLARGED PLANS & INTERIOR ELEVATIONS
A402 INTERIOR ELEVATIONS
A403 INTERIOR ELEVATIONS - CORRIDORS
A404 INTERIOR ELEVATIONS - CORRIDORS
A405 ENLARGED PLANS & INTERIOR ELEVATIONS - CONTROL
CENTERS
A406 ENLARGED PLANS & INTERIOR ELEVATIONS - DEDUCT
ALTERNATE
A501 MISCELLANEOUS DETAILS
A511 CASEWORK SECTIONS & DETAILS
A512 CASEWORK SECTIONS & DETAILS
A513 HEADWALL DETAILS
A601 WALL TYPES, DOOR SCHEDULE & DETAILS
AF101-F FLOOR FINISH PLAN
AF101-P WALL PROTECTION PLAN
AF101-W WALL FINISH PLAN
AF601 FINISH SCHEDULE
AF602 FINISH SCHEDULE - DEDUCT ALTERNATE
AS101 SIGNAGE PLAN
F901 FURNITURE AND EQUIPMENT PLAN
F902 FURNITURE AND EQUIPMENT PLANS AND SCHEDULE
FX001 LEGEND & GENERAL NOTES
FX103 PARTIAL THIRD FLOOR PLAN
P001 LEGEND & GENERAL NOTES
PD102 PARTIAL SECOND FLOOR PLAN - REMOVALS
PD103 PARTIAL THIRD FLOOR PLAN - REMOVALS
PP102 PARTIAL SECOND FLOO RPLAN - NEW WORK
PP103A PARTIAL THIRD FLOOR PLAN - SANITARY WASTE AND VENT &
STORM - NEW WORK
PP103B PARTIAL THIRD FLOOR PLAN - DOMESTIC WATER - NEW WORK
PP103C PARTIAL THIRD FLOOR PLAN - MEDICAL GAS - NEW WORK
P501 SCHEDULES AND DETAILS
P901 SANITARY WASTE AND VENT DIAGRAM
M001 LEGEND & GENERAL NOTES
MD102 PARTIAL SECOND FLOOR PLAN - REMOVALS
MD103 PARTIAL THIRD FLOOR PLAN - REMOVALS
MH102 PARTIAL SECOND FLOOR PLAN - NEW WORK
MH103 PARTIAL THIRD FLOOR PLAN - DUCTWORK
MH104 ROOF PLAN
MP103 PARTIAL THIRD FLOOR PLAN - PIPING
M300 SECTIONS
M501 DETAILS
M502 DETAILS
M503 DETAILS
M601 SCHEDULES & DIAGRAMS
M602 SCHEDULES & DIAGRAMS
M701 CONTROLS & AUTOMATION
M702 CONTROLS & AUTOMATION
E001 LEGEND & GENERAL NOTES
E002 PHASING NOTES AND DESCRIPTIONS
ED103 PARTIAL THIRD FLOOR PLAN - REMOVALS
ED104 EXISTING SIGNALS CLOSET - REMOVALS
EL103 PARTIAL THIRD FLOOR PLAN - LIGHTING
EP103 PARTIAL THIRD FLOOR PLAN - POWER
ET103 PARTIAL THIRD FLOOR PLAN - TECHNOLOGY
ET104 EXISTING SIGNALS CLOSET - NEW WORK
ET105 PARTIAL THIRD FLOOR PLAN - SIGNALS PATHWAYS - BASE BID
ET106 PARTIAL FLOOR PLANS - PATHWAYS
E401 ENLARGED PLANS
E403 DEDUCT ALTERNATE PLANS - LIGHTING AND POWER
E501 DETAILS - SIGNALS
E502 DETAILS - SECURITY SYSTEM
E601 ELECTRICAL SCHEDULES
E602 SINGLE LINE DIAGRAM - NORMAL
E603 SINGLE LINE DIAGRAM - EMERGENCY
E701 LIGHTING FIXTURE DESCRIPTIONS
E702 LIGHTING FIXTURE DESCRIPTIONS
GENERAL CONSTRUCTION NOTES
1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE,
INTERNATIONAL BUILDING CODE, AND OTHER CODES AS IDENTIFIED ON THE
CODE DATA SHEET OR IN VHA PROGRAM GUIDE PG-18-3, TOPIC 01, CODES,
STANDARDS AND EXECUTIVE ORDERS WHICH CAN BE FOUND ON THE
DEPARTMENT OF VETERAN AFFAIRS, TECHNICAL INFORMATION LIBRRARY
WEBSITE.
2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE LATEST
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) AND
DEPARTMENT OF VETERANS AFFAIRS BARRIER FREE DESIGN GUIDE PG-18-13
WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERANS AFFAIRS
TECHNICAL INFORMATION LIBRARY WEBSITE.
3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE AND ACCEPT
EXISTING CONDITIONS PRIOR TO BIDDING. SITE VISITS TO BE COORDINATED
WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH, TO MATCH
ADJACENT EXISTING SURFACES, ANY EXISTING MATERIALS TO REMAIN THAT
ARE DAMAGED DURING THE COURSE OF DEMOLITION OR NEW WORK.
5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR INSTALLATION OF
NEW WORK, CONTRACTOR SHALL REPAIR EXISTING CONSTRUCTION TO
REMAIN OR PROVIDE NEW CONSTRUCTION TO MATCH EXISTING ADJACENT
SURFACES TO REMAIN.
6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS AND
DIMENSIONS PRIOR TO ORDERING, FABRICATING OR INSTALLING NEW
MATERIALS.
7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL EQUIPMENT, ETC. TO
BE INSTALLED AS PART OF THIS PROJECT, AND WHERE NECESSARY, MAKE
SPECIAL PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO FIT
THROUGH FINISHED OPENINGS.
8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET ACCESSORIES,
HAND RAILS, BUMPER RAILS, SHELVING, CASEWORK, MOUNTING BRACKETS
AND OTHER WALL MOUNTED ITEMS, AS INDICATED IN THE CONTRACT
DOCUMENTS AND AS RECOMMENDED BY PRODUCT MANUFACTURERS. ALL
WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.
9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES UNLESS
SPECIFICALLY NOTED OTHERWISE. IF NO FINISH IS INDICATED AT A
PARTICULAR SURFACE, CONTRACTOR SHALL PROVIDE FINISH(ES) AS
INDICATED AT SIMILAR CONDITIONS.
10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY OPERATIONAL
SYSTEMS WHICH COMPLY WITH STATED CODES AND REGULATIONS. WHERE
THE OMISSION OF A PART OR ELEMENT OF A SYSTEM WOULD RESULT IN THE
NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM, CONTRACTOR
SHALL INCLUDE SAID PART OR ELEMENT AS PART OF THE WORK.
11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE OR FIRE RATED
WALLS SHALL BE SMOKE/FIRE STOPPED AS REQUIRED BY THE RATING OF
THE WALL.
DRAWING INDEXGRAPHIC SYMBOLS
N N.T.S.Scale:
VICINITY MAP
N N.T.S.Scale:
CAMPUS PLAN
Revision s
Date
7 100% For Bid 03.09.2020
0-HR Smoke Partition
1-HR Fire Barrier (NFPA 101-8.3)
2-HR Fire Barrier (NFPA 101-8.3)
Smoke Barrier/ 1- HR Fire (NFPA 101-8.5)
Smoke Barrier/ 2-HR Fire
Means of Egress
Existing Wall to Remain
New Wall
Fire Extinguisher
CODE LEGEND
SUITE 2
7488 SF
SUITE 1
6080 SF
NOTE:
SUITES ILLUSTRATED CONFORM TO STATE OF CONDITION
DRAWING PREPARED BY FP&C DATED 10/25/13
TOTAL TRAVEL DISTANCE = 198'-2"
(MAXIMUM = 200'-0")
TOTAL TRAVEL DISTANCE =
152'-3" (MAXIMUM = 200'-0")
COMMON PATH OF
TRAVEL = 26'-1"
(MAXIMUM = 100'-0")
LONGEST DEAD
END CORRIDOR =
25'-9" (MAXIMUM =
30'-0")
EXISTING, TO
REMAIN
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G
IS
E T
R
ED RA
C H
TI
E C T
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
CODE DATA
G100
DWTH
17005.00
552-18-102
Dayton Ohio
N Scale: 1/16" = 1'-0"1
THIRD FLOOR CODE PLAN
Referenced Code: NFPA 101 Life Safety Code (2018 Edition)
Construction Type: Type I (332)
Use Group: Health Care Occupancy
Height: Partial 1 story renovation of an existing 9 story building (145'-10" existing overall building height)
Area: 13,173 SF
Occupant Load: 55 occupants
Protection: Fully suppressed
Chapter 6 Classification of Occupancy and Hazard of Contents
6.1.5 Health Care Occupancy.
6.2.2.3 Ordinary Hazard Contents.
Chapter 7 Means of Egress
7.2.1.4.3.1 Any door leaf in a means of egress leaves
more than one-half of the required width of the corridor.
7.3.1.2 Occupant Load Factor based on Inpatient
Treatment Department is 240 SF/person: 55 persons.
7.4 Number of means of Egress: 3.
7.5.1.2.1 Corridors to lead to means of egress without
passing through any intervening spaces other than corridors, lobbies or spaces permitted to be open to the corridor.
7.5.1.2.2 Corridors not required to be fire resistance
rated shall be permitted to open into open floor plan areas.
Chapter 8 Features of Fire Protection Table A.8.2.1.2 Fire Resistance Ratings for Type I (332)
Construction (per NFPA 220 Table 4.1.1)
- Columns: 3 hours
- Beams, Girders, Trusses: 3 hours
- Interior Nonbearing Walls: 0 hour
Table 8.3.3.2.2 Minimum Fire Rating for Opening Protectives in Fire Resistance Rated Assemblies
- 1 hour fire barrier requires 3/4 hour door with a vision panel no larger than 1296 sq. in.
- Smoke barriers require 1/3 hour door with a vision panel no larger than 1296 sq. in.
8.4.1 Smoke Partitions shall limit the transfer of smoke.
8.5.1 Smoke Barriers shall restrict the transfer of smoke
and have 1 hour fire resistance rating.
8.5.3 Fire Barriers that meet requirements of Section
8.5 shall be permitted to be used as a smoke barrier.
Chapter 9 Building Service and Fire Protection Equipment
9.6 Fire Detection, Alarm and Communications
Systems. Fire alarm system required per Section 19.3.4.1.
9.7 Automatic sprinkler system required by Section
19.4.2.1.
9.9 Portable fire extinguishers shall be installed, inspected, and maintained in accordance with
NFPA 10.
Chapter 10 Interior Finish, Content and Furnishings Table A.10.2.2 Interior Finish Classification Limitations for Health
Care (Existing) Exit Access Corridors: Class A or B.
Other Spaces: Class A or B.
10.2.8.1 Automatic Sprinklers permit use of Class B In lieu
of Class A and Class C In lieu of Class B.
Chapter 18 New Health Care Occupancies
18.1.1.1.4 The area of work is an existing hospital and
therefore falls under Chapter 18.
Table 18.1.6.1 Construction Type Limitations: Type I (332), sprinklered, no story limitations.
18.1.7 Occupant Load per Table 7.3.1.2.
18.2.3.4 Corridors in hospitals shall be not less than 8 feet in clear an unobstructed width.
18.2.5.2 Dead end corridors shall not exceed 30’.
18.2.5.3 Common path of travel shall not exceed 100’.
18.2.5.4 Every corridor shall have access to not less than
two approved exits without passing through any intervening spaces other than corridors or lobbies.
18.2.5.7.1.3 Hazardous areas within a suite shall be separated from the remainder of the suite IAW Section 18.3.2.1.
18.2.5.7.1.4 The subdivision of suites shall be by means of
noncombustible materials, and such partitions shall not be required to be fire rated.
18.2.5.7.2.3 (B) Sleeping suites shall not exceed 7,500 SF.
18.2.6.2.1 Travel distance from any point in a room to exit
shall not exceed 200’.
18.3.2.1.2 Boiler/Fuel fire equipment rooms, laundries larger than 100 SF, soiled linen rooms with volume exceeding 64 gal and storage rooms larger than 100 SF shall be protected by 1 hour fire barriers.
18.3.2.1.3 Storage rooms (clean supply and clean linen)
larger than 50 SF but not exceeding 100 SF shall be protected by smoke partitions.
18.3.2.4 Areas where medical gas is stored or administer
and the operation, testing and maintenance of medical gases shall be in accordance with NFPA 99.
18.3.4.1 Health care occupancies shall be provided with a
fire alarm system IAW Section 9.6.
18.3.5.1 Building containing health care occupancies shall
be protected throughout by approved, supervised automatic sprinkler systems IAW Section 9.7.
18.3.5.12 Portable fire extinguishers shall be provided IAW
Section 9.9.
18.3.6.2.2 No fire resistance rating is required for corridor walls.
18.3.6.2.3 Corridor walls shall form a barrier to limit the
transfer of smoke but are not required to be smoke barriers or smoke partitions.
18.3.6.3.1 Corridor doors shall be doors constructed to resist the passage of smoke.
18.3.7.3 Smoke barrier shall be constructed IAW Section
8.5 and shall have 1 hour fire resistive rating.
18.3.7.5.1 Not less than 30 net SF per patient in a hospital
shall be provided within the aggregate area of corridors, patient rooms and other low hazard areas on each side of the smoke barrier.
18.3.7.6 Doors in smoke barriers shall have 20 minute fire
resistive rating.
CODE DATA
Revision s
PHASING LEGEND
Temporary Construction Barrier and door.
Temporary door to have 45 min raiting.
Hardware to be lockable with a closer. Reuse existing door and hardware where possible.
Ensure all accessibility requirements are met.
Extend wall from floor to deck. See A601 for wall types. Wall type T1.0, typical.
Area of renovation.
Owner-Occupied Area. No work to be performed by Contractor this phase.
Owner-Occupied Area. No architectural work in current phase. PME work may be required.
See PME drawings for additional phasing requirements. Work to be performed by Contractor during off-hours (9pm - 5am).
Coordinate off-hour work with COR.
1.06
1.06
1.031.04 1.051.041.03
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G
IS
E T
R
ED RA
C H
TI
E C T
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
PHASING PLANS
G101
DWTH
17005.00
552-18-102
Dayton Ohio
A. Temporary partitions are suggested locations. Coordinate final location in field with C.O.R. Temporary partition locations are approximate and may need to be adjusted to meet project requirements.
B. Verify all conditions in the field prior to fabrication, erection and construction.
C. Any work done on adjacent floors to be completed and cleaned by end of second shift.
D. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
E. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
F. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R.
G. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. Confirm all locations with the C.O.R. Maintain all emergency egress paths.
H. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction.Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEPDrawings.
J. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for duct locations.
K. Extend all temporary partitions to structural deck above.
L. Existing power to occupied areas must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
M. Coordinate construction sequence with C.O.R. so that only one side (not less than 48") of any corridor in use is obstructed at any one time in order to maintain required egress.
N. Coordinate all work involving the generation of excessive noise so as to occur during normal operating hours, 0700 to 1500 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
P Relocate lights and sprinkler heads as required at temporary partitions.
GENERAL PHASING NOTES
N Scale: 3/32" = 1'-0"
PHASING PLAN - PHASE I
N Scale: 3/32" = 1'-0"
PHASING PLAN - PHASE II
1.03 Contractor access.
1.04 Staff/patient access.
1.05 Maintain access to waiting room.
1.06 See mechanical and structural drawings for detailed information regarding relocation of supply ductwork in this area.
PLAN NOTES
Revision s
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number on e-ei gh th in ch on e fo ot on e-qu ar te r in ch on e fo ot th re e-ei gh th s in ch on e fo ot on e-ha lf in ch on e fo ot th re e-qu ar te rs in ch on e fo ot on e in ch on e fo ot on e an d on e-ha lf in ch es on e fo ot th re e in ch es on e fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
GENERAL NOTES
S001
JBEF
17005.00 552-18-102
Dayton Ohio
GENERAL STRUCTURAL NOTES:
A. CODES AND SPECIFICATIONS
1. 2018 INTERNATIONAL BUILDING CODE.
2. ASCE/SEI 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.
3. ANSI/AISC 303-16, CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES AS MODIFIED
BY THE CONSTRUCTION DOCUMENTS.
4. ANSI/AWS D1.1, STRUCTURAL WELDING CODE– STEEL.
5. ADDITIONAL TECHNICAL SPECIFICATIONS IN THE PROJECT MANUAL.
B. DESIGN LOADS
1. SPECIAL LOADS AND/OR DESIGN DATA:
HOIST SELF WEIGHT: PER LIFT MANUFACTURER
HOIST LIFT CAPACITY: PER LIFT MANUFACTURER
C. CONCRETE
1. CONCRETE STRENGTHS:
a. INTERIOR SLAB ON METAL DECK: 4000 PSI, LIGHTWEIGHT (117 PCF).
2. PLACE NO PERMANENT LOAD, SUCH AS MASONRY WALLS, ON SUPPORTED SLABS UNTIL CONCRETE
HAS REACHED SPECIFIED STRENGTH AND ALL SHORING HAS BEEN REMOVED.
3. CONCRETE CONSTRUCTION TOLERANCES ARE AS SHOWN IN THE PROJECT SPECIFICATIONS.
4. SLABS ON METAL DECKS ARE TO BE CAST TO A CONSTANT THICKNESS OVER BEAMS, WITH MINIMUM
THICKNESS AS SHOWN ON THE DRAWINGS. ALLOW FOR MINIMUM EXTRA 1/2” OF CONCRETE TO
ACCOUNT FOR METAL DECK DEFLECTION. PURLINS AND GIRDERS ARE UNSHORED DURING SLAB
PLACEMENT. AFTER PLACEMENT, FINISH SLABS TO REQUIRED TOLERANCES PER THE PROJECT
SPECIFICATIONS.
D. REINFORCING STEEL
1. ALL REINFORCING BARS: 60 KSI YIELD.
2. PROVIDE TENSION SPLICES UNLESS NOTED OTHERWISE.
3. PROVIDE MINIMUM CLEARANCES BETWEEN REINFORCING STEEL AND CONCRETE SURFACES AS
SHOWN. IF NOT SHOWN, PROVIDE CLEAR COVER PER ACI. PLACE ALL REINFORCING AS SHOWN AND
DETAILED, AND WITHIN ACI TOLERANCE.
E. STRUCTURAL STEEL
1. ALL WORK SHALL CONFORM TO AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STANDARDS
AND THE PROJECT SPECIFICATIONS.
2. FABRICATOR SHALL MEET AISC CERTIFICATION STANDARD FOR STEEL BUILDING STRUCTURES PER
THE PROJECT SPECIFICATIONS.
3. MATERIAL:
a. WIDE FLANGE SHAPES: ASTM A992 (Fy 50 KSI).
b. HOLLOW STRUCTURAL SECTIONS (HSS): ASTM A500, GRADE B
HSS SQUARE AND RECTANGULAR Fy 50 KSI).
c. OTHER ROLLED SHAPES, PLATES AND BARS: ASTM A36 (Fy 36 KSI).
d. BOLTS: ASTM A325, 3/4" MIN. DIA., U.N.O.
4. ALL WELDING MATERIALS, WELDING PROCEDURES AND OPERATORS PERFORMING WELDING TO BE
QUALIFIED PER AWS D1.1.
5. PRIME PAINTING IS REQUIRED FOR ALL STEEL WHICH WILL BE VISIBLE IN THE COMPLETED BUILDING
AND IS NOT SCHEDULED TO RECEIVE FIRE PROOFING.
F. METAL DECK
1. ALL WORK SHALL CONFORM TO STEEL DECK INSTITUTE (SDI) STANDARDS AND THE PROJECT
SPECIFICATIONS.
2. DECK MANUFACTURER SHALL BE A CURRENT MEMBER OF SDI.
3. MATERIAL, G-60 MINIMUM GALVANIZED STEEL:
a. 2" DEEP, 18 GAGE MIN. THICKNESS, COMPOSITE METAL FLOOR DECK.
4. MINIMUM ATTACHMENT OF FLOOR DECK: FASTEN TO ALL SUPPORTS WITH NOT LESS THAN 5/8" DIA.
FUSION WELDS OR APPROVED FASTENERS SPACED 12" O.C..
G. FIREPROOFING
1. ALL LOAD BEARING METAL STRUCTURAL FRAMING REQUIRES SPRAY-ON FIREPROOFING. REFER TO
THE PROJECT SPECIFICATION FOR SPECIFIC REQUIREMENTS.
H. COORDINATION AND CONSTRUCTION
1. THE SPECIFICATIONS AND DRAWINGS COMPLEMENT EACH OTHER. BOTH SHALL BE THOROUGHLY
REVIEWED BEFORE PROCEEDING WITH ANY WORK. THE CONTRACTOR SHALL COMPLETE ALL WORK
REQUIRED AND NECESSARY FOR THE PROJECT IN ACCORDANCE WITH THE PROJECT
SPECIFICATIONS, DRAWINGS, AND REFERENCED STANDARDS.
2. UNLESS OTHERWISE NOTED, DETAILS, SECTIONS AND NOTES ON THE STRUCTURAL DRAWINGS ARE
INTENDED TO APPLY TO SIMILAR SITUATIONS ELSEWHERE.
3. STRUCTURAL FRAMING PLANS ARE TYPICALLY DRAWN AS REFLECTED PLANS SHOWING BEAMS, WALLS, AND COLUMNS ON THE UNDERSIDE OF THE LEVEL SHOWN.
4. ALL FRAMING MEMBERS PROVIDED ARE FOR BIDDING PURPOSES ONLY. SUBMIT
MANUFACTURER'S DATA FOR THE PROPOSED EQUIPMENT TO STRUCTURAL ENGINEER FOR
VERIFICATION OR REDESIGN OF SUPPORTS PRIOR TO PREPARING SHOP DRAWINGS.
5. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL DETAILS, DIMENSIONS,
EMBEDDED ITEMS, SLEEVES, FLOOR PITCHES, DEPRESSIONS AND FILLS. OPENING SIZES WHEN SHOWN, ARE FOR GENERAL INFORMATION ONLY AND SHALL BE VERIFIED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND OTHER COORDINATION DRAWINGS AS APPLICABLE.
6. SHOP DRAWINGS PREPARED BY SUPPLIERS AND SUB CONTRACTORS SHALL BE REVIEWED BY THE
TRADE CONTRACTOR AND GENERAL CONTRACTOR OR CONSTRUCTION MANAGER PRIOR TO
SUBMITTING TO ARCHITECT/ENGINEER.
a. FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS AND CONDITIONS WHICH AFFECT
FABRICATION AND SHOW ON SHOP DRAWINGS.
b. VERIFY AND SHOW EXACT SIZE AND LOCATION OF ALL FLOOR, WALL AND ROOF OPENINGS, SLAB EDGES, EMBEDDED ANCHORS AND OTHER ITEMS.
c. SHOW AND LOCATE ALL MECHANICAL SLEEVES, EMBEDS, DRAINS, ETC. ON COORDINATION
DRAWINGS. ITEMS NOT SUBMITTED FOR REVIEW TO THE STRUCTURAL ENGINEER ARE NOT
PERMITTED IN OR THROUGH THE STRUCTURE.
d. SUBMIT COMPLETE SHOP DRAWINGS WITH MANUFACTURERS’ DATA, ETC. SHOW ALL
CONNECTIONS AND DETAILS NECESSARY TO FULLY DESCRIBE AND PROPERLY INSTALL THE
WORK.
e. STRUCTURAL ENGINEER’S REVIEW SHALL BE FOR GENERAL ARRANGEMENT AND
CONFORMANCE WITH THE STRUCTURAL INTENT ONLY.
7. THE SPECIFICATIONS AND STRUCTURAL DRAWINGS TYPICALLY REFER TO THE FINISHED STRUCTURE.
UNLESS NOTED OTHERWISE, THEY DO NOT PRESCRIBE THE METHOD OF CONSTRUCTION.
8. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF
ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO WORKING HOURS.
9. THE ARCHITECT’S AND ENGINEER’S OBSERVATION AND REVIEW OF CONTRACTORS’ PERFORMANCE DOES NOT INCLUDE REVIEW OF ADEQUACY OF CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR
THE CONSTRUCTION SITE.
I. MECHANICAL AND OTHER ITEMS EMBEDDED IN OR SUPPORTED FROM STRUCTURE
1. ALL TRADE CONTRACTORS (MECHANICAL, SPECIALTY, ETC.) ARE TO DESIGN
THEIR SYSTEMS, INCLUDING ATTACHMENTS TO THE BUILDING’S STRUCTURE WITHIN THE FOLLOWING
LIMITATIONS.
a. LOADS ARE TO BE DISTRIBUTED TO THE STRUCTURE IN A MANNER THAT DOES NOT EXCEED THE
LOAD ALLOWANCES NOTED UNDER DESIGN LOADS. ANCHORS ARE TO HAVE AN ULTIMATE
SAFETY FACTOR OF AT LEAST 4.0.
b. LOADS SUPPORTED BY WIDE FLANGE BEAMS ARE TO BE APPLIED IN A MANNER WHICH DOES NOT
CAUSE TORSION ABOUT THE LONGITUDINAL AXIS OF THE BEAM.
2. THE SIZE AND LOCATION OF EQUIPMENT, MUST BE COORDINATED WITH SUPPORTING STRUCTURAL
STEEL AND/OR ANGLE FRAMES. TRADE CONTRACTOR(S), GENERAL CONTRACTOR AND
CONSTRUCTION MANAGER MUST ENSURE ACCURATE DIMENSIONAL INFORMATION IS PROVIDED TO
STEEL FABRICATOR PRIOR TO FABRICATION.
3. UNLESS OTHERWISE NOTED, DO NOT HANG OR OTHERWISE SUPPORT ANY ITEMS FROM METAL
DECKS. USE CONCRETE ANCHORS TO SUPPORT FROM CONCRETE SLABS CAST ON METAL DECK.
J. QUALITY CONTROL AND ASSURANCE
1. THE CONTRACTOR SHALL PERFORM QUALITY CONTROL, TESTING AND INSPECTION OF ALL WORK AS REQUIRED BY THE CONTRACT DOCUMENTS, INCLUDING REFERENCED CODES, SPECIFICATIONS AND
STANDARDS.
2. THE STRUCTURAL ENGINEER MAY GENERALLY OBSERVE THE PROGRESS OF THE WORK, BUT HIS
OBSERVATION SHALL NOT BE CONSTRUED AS INSPECTION.
Revision s
1 FOR BID 03.09.2020
CHANNEL PER PLAN.
EXISTING 5 1/4" LIGHTWEIGHT
CONCRETE AND STEEL DECK FLOOR
SYSTEM.
PROVIDE NON-SHRINK GROUT TIGHT TO
BOTTOM OF EXISTING METAL DECK.
EXISTING WF BEAM PER PLAN.
PL6"x4-1/2"x1/4" SHEAR TAB WITH
SHORT SLOTTED HOLES, WELDED
TO WEB OF EXISTING BEAM.
(2) 3/4" BOLTS AT 3" GAGE.
PROVIDE SELF TAPPING SCREWS AT 1'-0"
O.C. THROUGH EXISTING ROOF DECK.
1 1/2" MAX
C BEAMLC BEAML
UNISTRUT AND BEAM CLAMP BY LIFT
MANUFACTURER.
EXISTING WF BEAM.
EXISTING FIREPROOFING.
REMOVE AS REQUIRED AND
RESTORE AFTER
INSTALLATION OF UNISTRUT,
REFER TO SPECIFICATION.
UNISTRUT AND BEAM CLAMP BY LIFT
MANUFACTURER.
EXISTING WF BEAM.
EXISTING FIREPROOFING.
REMOVE AS REQUIRED AND
RESTORE AFTER
INSTALLATION OF UNISTRUT,
REFER TO SPECIFICATION.
ANGLE TOP AND BOTTOM BY
LIFT MANUFACTURER.
UNISTRUT COLUMN INSERTS
AND TRACK BY LIFT
MANUFACTURER.
T/SLAB
REFER TO ARCH
EXISTING WF BEAM PER PLAN.
(2) #3 BARS, BY 2'-0" LONG
EVENLY SPACED ACROSS SLAB,
BOTH ENDS OF OPENING. EPOXY DOWEL 6" INTO
EXISTING SLAB WITH HILTI
HIT-HY 200 EPOXY.
NEW 2", 18 GAUGE FLOOR DECK.
ATTACH TO EXISTING BEAMS WITH
5/8" DIA PUDDLE WELDS OR
APPROVED FASTENER SPACED AT
1'-0"OC.
CUT EXISTING SLAB BACK TO
CENTERLINE OF BEAM.
PROVIDE NEW LIGHTWEIGHT
CONCRETE SLAB OVER METAL DECK.
3'-9" ± C BEAML
EXISTING WF BEAM.
UNISTRUT AND BEAM
CLAMP BY LIFT
MANUFACTURER.
UNISTRUT PER HOIST
MANUFACTURERS DRAWINGS.
HANGER DESIGN BY LIFT
MANUFACTURER. CENTER
CONNECTION UNDER EXISTING BEAM.
EXISTING FIREPROOFING.
REMOVE AS REQUIRED AND
RESTORE AFTER INSTALLATION
OF UNISTRUT, REFER TO
SPECIFICATIONS.
NEW EXHAUST FAN OPENING.
REFER TO MECHANICAL ROOF
PLAN DRAWING FOR
LOCATIONS.
NEW C7x9.8 TO ATTACH TO AND SPAN
BETWEEN NEW CHANNELS. ALIGN
BACK OF CHANNEL WITH EDGE OF
OPENING. REFER TO SIMILAR DETAIL 1
ON S100 FOR CONNECTION
INFORMATION.
NEW C7x9.8 TO ATTACH TO AND SPAN
BETWEEN EXISTING WIDE FLANGE
BEAMS. ALIGN BACK OF CHANNEL WITH
EDGE OF OPENING. REFER TO SIMILAR
DETAIL 1 ON S100 FOR CONNECTION
INFORMATION
EXISTING COMPOSITE
WIDE FLANGE BEAM.
EXISTING COMPOSITE
WIDE FLANGE BEAM.
EXISTING 5 1/4" CONCRETE AND
STEEL ROOF DECK SYSTEM
VA
RI
ES
9'-
0"
TO
9'-
4"
2'- 1"
2'-3"±
A B
2.1
4.2
3.1
F
EDC
5.3
4.65
5.2
E9
E8
EX W24x94 EX W24x68
1.2
E1
1.5
2.2
3.2
4.1
3.05
4.6
EX W24x68 EX W24x68 EX W24x68
EX
W x6
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX W21x44
EX W21x111 EX W21x62 EX W21x62 EX W21x62
EX
W x5
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x5
EX
W x4
EX
W x3
EX
W x5
5 EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x2
EX
W x5
EX
W x2
EX B2
EX
B1
EX
W x5
EX
W x2
EX
W x2
EX
W x2
EX
W x1
EX
W
8x
EX
W
8x
EX
W
8x
EX
W
8x
EX
W
8x
18 EX
W 8x
EX
W x5
0EX W16x26EX W21x57
EX W21x101
EX W21x101
EX W24x94 EX W24x94
EX W21x50 EX W21x50 EX W21x50
EX W21x73 EX W21x68 EX W21x68
EX W21x50
EX W18x35
EX
W x3
EX
W x2
EX
W x2
EX
W x2
EX
W x5
EX W16x26
EX
B2
EX
B2
EX
B2
EX
B2
EX
B2
EX B1
EX W21x68
EX
B1
TYP
TYP
TYP
TYP
6 6
6 6 6 6
9'-0" ± 9'-0" ± 9'-0" ± 9'-0" ± 9'-4" ± 9'-4" ± 9'-4" ± 9'-4" ± 9'-4" ± 9'-4" ± 9'-4" ± 9'-4" ± 9'-4" ± 6'-8" ± 6'-8" ± 7'-3 1/2" ± 3'-4 1/2" ±
2'- 0"
'-1
'-1
1"
'-0
'-0
'-0
A B
2.1
9'-0" ± 9'-0" ± 3'-9" ± 9'-0" ±
EX W24x117
EX
W x7
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX
W x4
EX W21x111
EX W8x18
EX W8x18
WITH ARCH
4'-5 1/2"±
VERIFY
W
ITH
AR
CH
4'- 8"
VE
RI
FY
C7x9.8
C7 x9
.8
4'-
/4"
3 4 5
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number on e-ei gh th in ch on e fo ot on e-qu ar te r in ch on e fo ot th re e-ei gh th s in ch on e fo ot on e-ha lf in ch on e fo ot th re e-qu ar te rs in ch on e fo ot on e in ch on e fo ot on e an d on e-ha lf in ch es on e fo ot th re e in ch es on e fo ot
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
FRAMING PLANS AND DETAILS
S100
JBEF
17005.00 552-18-102
Dayton Ohio
1/8" = 1'-0"S100
B LEVEL 4 FRAMING PLAN
1/8" = 1'-0"S100
A LEVEL 3 PARTIAL FRAMING PLAN
DRAWING NOTES:
1. NEW C7x9.8 TO ATTACH TO AND SPAN BETWEEN EXISTING WIDE FLANGE BEAMS. REFER
TO DETAIL 1 THIS DRAWING FOR CONNECTION INFORMATION.
2. NEW C7x9.8 TO ATTACH TO AND SPAN BETWEEN EXISTING WIDE FLANGE BEAM AND NEW
CHANNEL. REFER TO SIMILARDETAIL 1 THIS DRAWING FOR CONNECTION INFORMATION.
3. NEW FLOOR PENETRATION PER ARCHITECTURAL DEMOLITION DRAWINGS.
4. PROVIDE NEW 2" STEEL FLOOR DECK TO COVER EXISTING FLOOR PENETRATION. REFER
TO DETAIL 2, THIS DRAWING.
5. PROVIDE NEW LIGHTWEIGHT CONCRETE SLAB OVER METAL DECK. FINISHED ELEVATION
OF SLAB IS TO MATCH EXISTING.
6. HSS6x3x1//4 GRAB BAR SUPPORT STEEL. REFER TO ARCHITECT DETAILS 1 AND 2 ON A501.
7. C7x9.8 MECHANICAL PENETRATION SUPPORT CHANNELS. REFER TO TYPICAL PLANDETAIL
6, THIS DRAWING. COORDINATE FINAL LOCATION WITH MECHANICAL DRAWINGS.
1 1/2" = 1'-0"S100
1 SECTION
3" = 1'-0"S100
3 DETAIL
UNISTRUT AT BEAMS OF SAME DEPTH
3" = 1'-0"S100
4 DETAIL
UNISTRUT AT BEAMS OF DIFFERENT DEPTHS
1 1/2" = 1'-0"S100
2 SECTION
3" = 1'-0"S100
5 DETAIL
HANGER DIRECTLY BELOW EXISTING BEAM
NOTE: ALL STRUCTURAL COMPONENTS REQUIRED TO SUPPORT PATIENT LIFTS ARE TO BE PROVIDED BY AND DESIGNED BY LIFT MANUFACTURER. STUCTURAL COMPONENTS AND UNISTRUT ARE TO BE SHOWN ON HVAC COORDINATION DRAWINGS. ALL UNISTRUT IS TO BE PROVIDED ABOVE BOTTOM OF
EXISTING STEEL BEAMS, PER REFERENCE DETAILS 3, 4, AND 5, THIS DRAWING.
3/8" = 1'-0"S100
6 PLAN DETAIL
Revision s
1 FOR BID 03.09.2020
F
1.2
EDCBA B3 B6 C5 E1
1.5
2.2
3.2
4.1
5.3
4.2
3.1
2.1
D2C6
5.2
E9E8
3.05
4.6
AREA OF DEDUCT ALTERNATE
AD101
2.01 2.02
7'-2 3/8"
2.03
2.01 2.03
2.04
2.06
2.03
2.09
2.11
2.05
2.03 2.09
2.03
2.01
2.04
2.06
2.06
2.04
2.06
2.03
2.02
2.06
2.04
2.02
2.04
2.06
2.03
2.04
2.06
/2
2.04 2.17
2.04
2.06
2.04
2.06
2.12
2.03
2.02
2.06
2.04
2.02
2.03
2.06
2.04
2.03
2.04
2.06
2.02
2.06
2.05
2.02 2.03
2.09 2.03
2.03
2.01
2.01
2.04
2.06
2.03
2.09
2.01
2.03
2.01 2.01
2.03
2.09
2.03
2.01
2.01
2.03
2.09
2.03
2.01
2.01
2.03
2.09
2.03
2.14 2.01
2.03
2.06
2.03
2.09
2.04
2.03
2.09
2.01
2.01
2.01 2.03
2.04
2.06
2.01
2.01 2.03
2.03
2.09
2.04
2.06
2.03
2.09
2.03
2.01
2.03
2.09 2.03
2.03
2.04
2.06
2.04
2.06
2.18
2.16
2.16
2.18
2.18
2.06
2.06
2.16
2.06
2.15
2.06
2.04
2.19
2.03
2.04
2.06 2.04
2.06 2.04
2.06
2.04
2.06
2.03
2.09
2.03
2.04
2.06
2.01
2.03 2.01
2.09
2.03
2.01
2.04
2.06
2.03 2.012.01
2.09
2.03
2.04
2.06
2.03 2.03
2.03 2.04
2.06
2.09
2.03
2.04
2.06
2.03
2.01 2.01 2.03
2.03
2.09 2.09
2.03
2.01
2.01
2.04
2.06 2.06
2.04
2.01
2.03
2.09
2.03
2.01 2.04
2.06
2.06
2.04
2.09
2.03
2.03
2.01
2.01
2.03
2.01
2.03
2.09
2.01 2.04
2.06 2.04
2.06
2.03
2.03
2.09
2.01
2.01
2.09
2.03
2.04
2.06
2.08
2.03
6"
2.08
/4
2.06
2.11
2.14
2.04
2.06
2.12
2.05
2.03
2.03
2.02
2.02
2.08
2.04
2.06
2.04
2.06
2.04
2.06
2.04
2.06
2.12
2.04
2.06
2.06
2.16
2.08
2.04
2.06
2.04
2.06
2.06
2.22
2.08
2.04
2.06
2.04
2.06
2.04
2.06
2.09 2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.202.20
2.202.20 2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.19
2.19
2.21
2.21
2.212.04
2.06
2.12
2.04
2.06
2.12
2.04
2.06
2.12
2.23
2.24
2.07
2.07
2.07
2.07
2.07
2.07
2.07
2.07
2.07
2.07
2.01
2.06
2.04
2.03
2.03
2.14
2.14
2.25
2.21
2.18
2.07
2.07
2.07
2.07
2.04
2.06
2.04
2.06
2.04
2.06
2.06
2.04
2.04
2.06
2.12
2.29
Typ.
2.29
Typ.
2.29 Typ.
2.29 Typ.
2.29 Typ.
2.29
Typ.
2.29
Typ.
2.29 Typ.
2.29 Typ.
2.30
CONSULTATION
ROOM
3B102
OFFICE
3B103
LOUNGE
3B104
LOCKER
ROOM
3B104A
BED ROOM
- SICU
3B105
UTILITY
ROOM,
SOILED
3B106
STORAGE,
STRETCHER/
WHEELCHAIR
3B107
BED ROOM
- SICU
3B108
UTILITY
ROOM,
CLEAN
3B109
BED ROOM
- SICU
3B110
COMM
CLOSET
3B111
BED ROOM
- SICU
3B112
BED ROOM
- SICU
3B113
OFFICE
3B114
KITCHEN,
NOURISHMENT
3B115
MEDICATION
PREP.
3B116
OFFICE,
PHYSICIAN
3B117
OFFICE
3B118
UTILITY
ROOM,
SOILED
3B119
OFFICE
3B120
BED ROOM
- SICU
3B121
BED ROOM
- SICU
3B122
BED ROOM
- SICU
3B123
BED ROOM
- SICU
3B124
BED ROOM
- SICU
3B125
TOILET,
FEMALE
3B126
BED ROOM
- ISOLATION
3B127
TOILET,
MALE
3B128
ANTE
ROOM
3B129
STORAGE
3B129A
BED ROOM
- SICU
3B131
ANTE
ROOM
3B132
ANTE
ROOM
3B133
BED ROOM
- SICU
3B134
BED ROOM
- MICU
3B135
ANTE
ROOM
3B136
BED ROOM
- MICU
3B137
BED ROOM
- MICU
3B138
TOILET,
CONGREGATE
3B139
BED ROOM
- MICU
3B140
BED ROOM
- CCU
3B141
BED ROOM
- MICU
3B142
BED ROOM
- MICU
3B143
UTILITY
ROOM,
CLEAN
3B130
ELECTRICAL
CLOSET
3B144
BREAK
ROOM
3B145
KITCHEN,
MISC
3B146
STORAGE,
GENERAL
3B147
HOUSEKEEPING
AID CLOSET
3B148
OFFICE
3B149
OFFICE
3B150
KITCHEN,
NOURISHMENT
3B151
LINEN
ROOM,
SOILED
3B152
TOILET,
CONGREGATE
3B153
MEDICATION
PREP.
3B154
UTILITY
ROOM,
CLEAN
3B155
UTILITY
ROOM,
SOILED
3B156
BED ROOM
- MICU
3B157
BED ROOM
- MICU
3B158
BED ROOM
- MICU
3B159
BED ROOM
- MICU
3B160
BEDROOM -
RESIDENT
ON-CALL
3B161
CORRIDOR
C3-13
CORRIDOR
C3-12
CORRIDOR
C3-14
CORRIDOR
C3-18
CORRIDOR
C3-19
CONTROL
CENTER
C3-15
CORRIDOR
C3-17
CORRIDOR
C3-22
CORRIDOR
C3-23
CORRIDOR
C3-26
CORRIDOR
C3-24
CONTROL
CENTER
C3-25
CORRIDOR
C3-20
CORRIDOR
3C-27
Corridor
3C-9
PLAN AREA
DCB
4.2
3.1
2.1
2.17
2.19
2.19
2.04
2.06
2.08
2.16
2.03
2.06
2.18
2.06
2.18
2.07
2.04
2.06
2.06
2.16
2.04
2.06
2.04
2.06 2.07
2.07
2.07
2.07
2.07
2.07
2.04
2.06
2.07
2.07
2.06
2.08
2.22 2.07
2.07
2.07
2.07
2.04
2.06
2.04
2.06
2.03
2.04
2.06
2.04
2.06
2.04
2.06
2.06
2.18
2.07
2.07
2.07
2.07
2.04
2.06
2.04
2.06
2.04
2.06
2.07
2.07
2.07
2.04
2.06
2.04
2.06
2.07
2.07
2.21
2.04
2.06
2.07 2.04
2.15
2.06
2.16
2.06
2.16
2.07
2.04
2.12
2.16
2.03 2.03
2.24
2.11
2.14
2.14
2.11
2.14
2.14
2.02
UTILITY
ROOM,
SOILED
3B106
STORAGE,
STRETCHER/
WHEELCHAIR
3B107
UTILITY
ROOM,
CLEAN
3B109
COMM
CLOSET
3B111
OFFICE
3B114
KITCHEN,
NOURISHMENT
3B115
MEDICATION
PREP.
3B116
OFFICE,
PHYSICIAN
3B117
OFFICE
3B118
UTILITY
ROOM,
SOILED
3B119
TOILET,
FEMALE
3B126
TOILET,
MALE
3B128
STORAGE
3B129A
TOILET,
CONGREGATE
3B139
UTILITY
ROOM,
CLEAN
3B130
ELECTRICAL
CLOSET
3B144
BREAK
ROOM
3B145
KITCHEN,
MISC
3B146
STORAGE,
GENERAL
3B147
HOUSEKEEPING
AID CLOSET
3B148
OFFICE
3B149
OFFICE
3B150
KITCHEN,
NOURISHMENT
3B151
LINEN
ROOM,
SOILED
3B152
TOILET,
CONGREGATE
3B153
MEDICATION
PREP.
3B154
UTILITY
ROOM,
CLEAN
3B155
CORRIDOR
C3-13
CONTROL
CENTER
C3-15
CORRIDOR
C3-17
CORRIDOR
C3-22
CORRIDOR
C3-23
CORRIDOR
C3-24
CONTROL
CENTER
C3-25
Means of Egress
Wall to be Demolished
Existing Wall to Remain
Door and Frame to be Demolished.
Reuse as temporary doors where possible
DCB
4.2
3.1
2.1
2.04
2.15 2.17
2.04
2.06
2.032.04
2.06
2.19
2.19
2.02 2.24
2.11
2.14
2.14
2.11
2.14
2.14
UTILITY
ROOM,
SOILED
3B106
STORAGE,
STRETCHER/
WHEELCHAIR
3B107
UTILITY
ROOM,
CLEAN
3B109
COMM
CLOSET
3B111
OFFICE
3B114
KITCHEN,
NOURISHMENT
3B115
MEDICATION
PREP.
3B116
OFFICE,
PHYSICIAN
3B117
OFFICE
3B118
UTILITY
ROOM,
SOILED
3B119
TOILET,
FEMALE
3B126
TOILET,
MALE
3B128
STORAGE
3B129A
TOILET,
CONGREGATE
3B139
UTILITY
ROOM,
CLEAN
3B130
ELECTRICAL
CLOSET
3B144
BREAK
ROOM
3B145
KITCHEN,
MISC
3B146
STORAGE,
GENERAL
3B147
HOUSEKEEPING
AID CLOSET
3B148
OFFICE
3B149
OFFICE
3B150
KITCHEN,
NOURISHMENT
3B151
LINEN
ROOM,
SOILED
3B152
TOILET,
CONGREGATE
3B153
MEDICATION
PREP.
3B154
UTILITY
ROOM,
CLEAN
3B155
UTILITY
ROOM,
SOILED
3B156
CORRIDOR
C3-13
CORRIDOR
C3-14
CONTROL
CENTER
C3-15
CORRIDOR
C3-17
CORRIDOR
C3-22
CORRIDOR
C3-23
CORRIDOR
C3-24
CONTROL
CENTER
C3-25
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G
IS
E T
R
ED RA
C H
TI
E C T
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
DEMOLITION PLANS
AD101
DWTH
17005.00
552-18-102
Dayton Ohio
GENERAL DEMOLITION NOTES
A. Remove all existing partitions shown with dashed line. Repair wall and floor finishes to match adjacent surfaces at areas of removal or scheduled new surfaces as required.
B. Remove all existing borrowed lights, doors and hollow metal frames where indicated with dashed line. Unused hardware shall be turned over to Owner. Box hardware before giving to Owner.
C. Remove wall-hung toilet room accessories and medical equipment as required and turn over to Owner.
D. See Plumbing, HVAC and Electrical Drawings for removal work associated with those trades.
E. Computer and communication cables and/or other wiring, piping, tubing, etc. serving other areas and functions located above ceiling or in walls of area to be remodeled shall be maintained during demolition/construction process.
Coordinate any required changes to these systems with the
COR.
F. Repair existing walls to match adjacent undisturbed wall where cabinets, countertops, etc. are shown to be removed.
G. Prepare walls and floor slabs as required to receive new finish materials where existing finish is indicated to be removed.
H. Remove existing corner guards in areas to be remodeled.
J. Protect existing fireproofing on all structural steel members and repair as needed.
PLAN NOTES
N Scale: 1/8" = 1'-0"1
DEMOLITION PLAN - BASE BID
N N.T.S.Scale:
KEY PLAN
N Scale: 1/8" = 1'-0"2
DEMOLITION PLAN - DEDUCT ALTERNATE #1
2.01 Remove existing window.
2.02 Remove existing base cabinets, wall cabinets and countertop.
2.03 Remove existing plumbing fixtures and all associated
accessories. See Plumbing Drawings.
2.04 Remove existing VCT flooring and rubber base. Prepare
subfloor for new scheduled finish this area.
2.05 Remove existing portion of wall as required for new opening.
See New Work Plan and Door Schedule.
2.06 Remove existing acoustic ceiling tile, grid, lights and all ceiling mounted accessories this area.
2.07 Remove existing door leaf. Frame to remain.
2.08 Remove ceramic wall tile and associated gypsum board.
2.09 Remove existing utility column, associated framing, and
associated utilities. See PME drawings.
2.11 Remove existing nurse station casework.
2.12 Remove all existing wall mounted equipment, accessories, corner guards, handrails, bumper guards, etc.
2.14 Remove existing gypsum board soffit and support framing.
2.15 Remove existing gypsum board ceiling.
2.16 Remove existing ceramic floor, base, and setting material.
Prepare subfloor for new scheduled finish.
2.17 Remove existing lockers.
2.18 Remove existing carpet flooring and rubber base. Prepare subfloor for new scheduled finish and base this area.
2.19 Remove existing cross corridor door and wall.
2.20 Remove existing patient lifts and supports.
2.21 Mechanical chase, to remain.
2.22 Remove porcelain floor tile and base
2.23 Gas valve box locations to remain.
2.24 Existing pneumatic tube system to be relocated as shown on new plans. System shall be non-operational for no more than 10 days.
2.25 Existing floor penetration to be infilled per new work. See structural drawings.
2.29 Remove existing window sill.
2.30 Remove existing fire extinguisher cabinet. Patch wall as required.
DEMOLITION LEGEND
N Scale: 1/8" = 1'-0"3
DEMOLITION PLAN - DEDUCT ALTERNATE #2
Revision s
Date
6 95% Owner Review Resubmittal 11.09.2018
5 95% Owner Review Resubmittal 09.28.2018
4 95% Owner Review Resubmittal 08.20.2018
3 95% Owner Review 06.15.2018
2 Design Development 04.30.2018
1 Schematic Design 02.23.2018
1.2
EDCBA
1.5
2.2
3.2
3.1
2.1
E8
3.05
9 1/2"
10' - 9 5/8"
1' - 9 5/8"
/8
/4
/8
RESTROOM
3B123a
S2.0S2.0
RESTROOM
3B124a
ANTE
ROOM
3B123b
BED ROOM
3B125
CORRIDOR
C3-19
TOILET,
FEMALE
3B126
TOILET,
MALE
3B128
CORRIDOR
C3-17
CONTROL
CENTER
C3-15
MED ROOM
3B119
ELECTRICAL
CLOSET
3B144
BED ROOM,
INFECTION
CONTROL
3B124
STORAGE
3B164
STORAGE
3B145
RESTROOM
3B125a
RESTROOM
3B135a
BED ROOM,
BARIATRIC
3B135
BED ROOM,
INFECTION
CONTROL
3B137
RESTROOM
3B137a
RESTROOM
3B138a
A N
T E
R O
O M
B b
A N
T E
R O
O M
B b
BARIATRIC,
INFECTION
CONTROL
3B138
BED ROOM
3B140
UTILITY
ROOM,
CLEAN
3B130
CLEAN
LINEN
3B139
SOILED
UTILITY
3B152
NOURISHMENT
3B153
CORRIDOR
C3-20
RESTROOM
3B140a
RESTROOM
3B142a
ALCOVE
TRAY
STORAGE
3B141a
BED ROOM
3B142
CONTROL
CENTER
C3-25
BED ROOM
3B160
ALCOVE,
WHEELCHAIR
3B171
R E
S T
R O
O M
B a
RESTROOM
3B159a
BED ROOM
3B159
CORRIDOR
C3-26
MED ROOM
3B154
NURSE
WORKROOM
3B151
STORAGE
3B149
OFFICE
3B150
STORAGE
3B148
HAC
3B155
STORAGE
3B168
OFFICE
3B147
BREAK
ROOM
3B146
OFFICE
3B117
NURSE
WORKROOM
3B114
S .0
S1.1
S1.1
S .0
S1.1-N
S1.1-N
S1.1
S .1
S1.1
S1.1
S1.1
S2.0
S2.0S2.0
S2.0
S2.0
S2.0S2.0
S1.1
S2.0
S1.0-F
S1.1
S1.1
S2.0
S2.0
S1.1 S2.0
S2.0
S2.0
S1.0-F S1.0-F
S1.0-F
4' - 5 1/2"
4 1/4"
6' - 7 3/8" 4 7/8"
7 7/8"
4 1/4" 5' - 3 3/8"4
/4
/4
/8
/4
/4
S1.0-F
/8
/4
/4
/8
/8
/8
120°
13' - 6 7/8" 1' - 0 1/8" 2' - 0"
120°
3' - 0 1/8" 13' - 7 3/8"
3' - 11 3/8" 3' - 11 1/8" 4' - 4 7/8"
4 7/8"
4' - 4 7/8" 3' - 11 1/2" 3' - 11 1/2" 8' - 0 1/2" 1' - 11 1/4" 8' - 0 1/2"
5' - 4 1/8"
4 1/4"
11"
4 1/4"
120° 120° 120°
1' - 9 5/8" 4' - 5 3/4" 3' - 4 1/2" 4 7/8" 3' - 10"
ALIGN
/8
/8
/8
/4
/8
/4
0°
/2
/4
/4
/2
/4
A L
IG
N
ALIGN
14' - 4 3/4"
4 7/8"
6' - 2"
4 7/8"
2' - 6 1/2" 4' - 5 1/8" 2' - 6 1/2"
4 7/8"
S1.0-F
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN1
/2
/8
/2
/8
/8
/8
/4
/8
/8
/2
/4
/8
7' - 5 3/8" 3' - 11 3/4"
1' - 9 5/8"
4' - 8 3/8" 3' - 11 1/8" 3' - 6" 8' - 0 1/2" 1' - 11 1/4" 8' - 0 1/2" 7' - 9 3/8"
4 7/8"
2' - 10 5/8"
4 7/8"
4' - 4 1/8"
4 7/8"
7' - 9" 8' - 0 1/2" 11 5/8"
/2
/4
/2
2' - 2 1/2"
ALIGN S2.0
ALIG
N
S2.0S2.0
/2
S2.0
1' - 9 5/8" 12' - 1 1/8"
/8
/8
S2.0S2.0
2' - 6" 6 1/8" 13' - 5 3/8"
/2
/8
/4
/8
/4
/4
5' - 3 3/8"
1' - 7 1/2"
/4
13' - 5 3/4" 10 3/4" 2' - 2"
M
IN
/8
/8
/8
/4
/8
/2
5' - 5 1/4"
4 1/4"
11"
4 1/4"
1' - 7 1/2"
S2.0S2.0
4 7/8"
3' - 0 1/8" 13' - 1 1/2"
/2
/8
/4
/8
/8
/8
6'
9'
/8 " 1'
/8
4' - 7 7/8" +/-
/4
/8
8' - 0" MIN.
135°
/8
/4
/8
/8
/8
/8
ALIGN
/8
S2.0S2.0
S2.0
/2
/8
"4
/8
ALIGN
ALIGN
2' - 8 7/8"
/2
" 10' - 0 5/8"
13' - 4 3/4"
4'
/8
3'
0"
4"
6'
1/
4"
3'
0"
1/ 2"
2' - 0 5/8"
ALIGN
ALIGN
ALIGN ALIGN ALIGN
45°
6' - 4 7/8"
ALIGN
BEDROOM -
RESIDENT
ON-CALL
3B161
S2.0S2.0
9"
3' - 6"
CORRIDOR
3C-27
S1.0-F
S1.0-F
S1.0-F
S1.0-F
S1.0-F
S1.0-F
S1.0-F
E1.0
E1.0
E1.0
S1.0-N
AREA A
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G
IS
E T
R
ED RA
C H
TI
E C T
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
ENLARGED DIMENSION PLAN
A101-D1
DWTH
17005.00
552-18-102
Dayton Ohio
N Scale: 1/4" = 1'-0"
ENLARGED DIMENSION PLAN A GENERAL NOTES
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. All partitions shall be type 'S1.0' unless noted otherwise.
E. See enlarged plans for additional notes.
F. See code plan for existing rated construction. Firestop all new penetrations to maintain integrity of existing rated construction.
Additionally, firestop up to a maximum of 100 penetrations and/or 100 SF of existing, unfirestopped penetrations through existing rated construction.
N.T.S.Scale:
Key Plan
Revision s
FEDCBA B3 B6 C5 E1
3.2
4.1
4.7
5.3
4.2
3.1
D2C6
3.05
4.6
OFFICE
3B120
CORRIDOR
C3-18
BED ROOM
3B121
RESTROOM
3B121a
ALCOVE,
WHEELCHAIR
3B165
RESTROOM
3B122a
BED ROOM
3B122
ALCOVE
CRASH
CART
3B166
RESTROOM
3B110a
NOURISHMENT
3B115
BED ROOM,
INFECTION
CONTROL
3B123
CORRIDOR
C3-19
CONTROL
CENTER
C3-15
NURSE
WORKROOM
3B114
CLEAN
LINEN
3B116
COMM
CLOSET
3B111
OFFICE
3B117
BREAK
ROOM
3B146
OFFICE
3B147
CORRIDOR
C3-23
STORAGE
3B168
HAC
3B155
STORAGE
3B106
BED ROOM,
BARIATRIC
3B110
BED ROOM
3B108
RESTROOM
3B108a
ALCOVE
WHEELCHAIR
3B112
BED ROOM
3B105
RESTROOM
3B105a
CONSULTATION
ROOM
3B102
RESTROOM
3B158a
BED ROOM
3B158
CORRIDOR
C3-26
BED ROOM
3B159
UTILITY
ROOM,
CLEAN
3B109
SOILED
UTILITY
3B107
S2.0
S2.0
S2.0
S1.1
S1.1
S1.1
S2.0
S1.1
S1.1
S2.0
S1.1
S2.0
S2.0
S2.0
S2.0
S2.0
S2.0
S2.0
S1.1
S1.1
S2.0S2.0
S2.0
S2.0
S2.0S2.0
S1.0-F
/8
0°
/2
/2
/8
/8
/8
/4
/8
/4
/8 " 4
/8
/8
/8
/8
7' - 7 3/8" 3' - 11 3/4" 1' - 9 5/8"
/4
/2
/4
/2
/4
/8
/2
/8
A L
IG
N
120°
ALIGN
120°
/8
/8
120°
ALIGN
ALIGN
A L
IG
N
ALIGN
6' - 3 1/8"
6' - 7 7/8"
4 7/8"
5' - 4 1/2" 6' - 7"
ALIGN
CORRIDOR
C3-12
OFFICE
3B103
/8
/8
/8
/8
7' - 2 1/2"
/8
/4
/8
/2
S2.0
2' - 10 7/8" 5' - 10 1/2" 3' - 7 3/8" 3' - 11 1/8" 3' - 8 3/8" 8' - 0 1/2" 1' - 11 1/4" 8' - 0 1/2" 6' - 0 1/2"
4 7/8"
5' - 4" 1' - 3" 8' - 0 1/2" 10' - 0 1/2" 2' - 7 1/8"
4' - 0 7/8"
4 1/4"
8 1/2"
4 1/4"
5' - 4 5/8"
4 7/8"
3' - 9" 13' - 3 3/4"
1' - 0 1/8"
/4
/4
11' - 9 7/8"
1' - 10 1/2"
2' - 10 1/2"
/8
/8
/8
S2.0
1' - 10" 3' - 6"
5' - 3 3/4"
4 1/4"
8 1/2"
13' - 11 7/8" 4' - 9" 4 7/8"
1' - 7 1/8"
5' - 3 3/8" 1' - 0 3/4"
/8
/8
ALIGN
/8
M
IN
/4
/4
/4
/4
/8
/8
/2
/4
/8
/2
5' - 5 5/8" 2' - 2 1/2"
2' - 0"
13' - 10 3/4"
/4
3 5/8"
17' - 11"
11' - 7 1/8"
1' - 9 5/8"
/4
7' - 0"
SCRUBS
3B106a
3'
6"
4'
1"
9"
S2.0S2.0S2.0
S2.0 S2.0
S2.0
AREA B
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G
IS
E T
R
ED RA
C H
TI
E C T
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
ENLARGED DIMENSION PLAN
A101-D2
DWTH
17005.00
552-18-102
Dayton Ohio
N Scale: 1/4" = 1'-0"
ENLARGED DIMENSION PLAN B
GENERAL NOTES
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. All partitions shall be type 'S1.0' unless noted otherwise.
E. See enlarged plans for additional notes.
F. See code plan for existing rated construction. Firestop all new penetrations to maintain integrity of existing rated construction.
Additionally, firestop up to a maximum of 100 penetrations and/or 100 SF of existing, unfirestopped penetrations through existing rated construction.
N.T.S.Scale:
Key Plan
Revision s
DCB
3.1
2.1
CORRIDOR
C3-14
CORRIDOR
C3-19
CORRIDOR
C3-20
UTILITY
ROOM,
SOILED
3B106
STORAGE,
STRETCHER/
WHEELCHAIR
3B107
UTILITY
ROOM,
CLEAN
3B109
COMM
CLOSET
3B111
OFFICE
3B174
KITCHEN,
NOURISHMENT
3B175
MEDICATION
PREP.
3B176
OFFICE,
PHYSICIAN
3B117
OFFICE
3B177
UTILITY
ROOM,
SOILED
3B178
TOILET,
FEMALE
3B126
TOILET,
MALE
3B128
STORAGE
3B129A
TOILET,
CONGREGATE
3B139
UTILITY
ROOM,
CLEAN
3B130
ELECTRICAL
CLOSET
3B144
BREAK
ROOM
3B179
KITCHEN,
MISC
3B180
STORAGE,
GENERAL
3B147
HOUSEKEEPING
AID CLOSET
3B148
OFFICE
3B149
OFFICE
3B150
NOURISHMENT
3B151
LINEN
ROOM,
SOILED
3B152
TOILET
3B181
MEDICATION
PREP.
3B154
UTILITY
ROOM,
CLEAN
3B155
UTILITY
ROOM,
SOILED
3B182
CONTROL
CENTER
C3-15
CORRIDOR
C3-17
CORRIDOR
C3-22
CORRIDOR
C3-23
CONTROL
CENTER
C3-25
S1.0-F
S1.0-NS1.0-F
S1.0-F
S1.0-N
(C L
E A
R
DCB
3.1
2.1
CORRIDOR
C3-14
NOURISHMENT
3B115
ALCOVE
WHEELCHAIR
3B112
BREAK
ROOM
3B179
OFFICE,
PHYSICIAN
3B117
OFFICE
3B174
COMM
CLOSET
3B111
UTILITY
ROOM,
CLEAN
3B109
STORAGE,
GENERAL
3B147
KITCHEN,
MISC
3B180
STORAGE,
STRETCHER/
WHEELCHAIR
3B107
UTILITY
ROOM,
SOILED
3B106
UTILITY
ROOM,
SOILED
3B182
CORRIDOR
C3-23
UTILITY
ROOM,
CLEAN
3B155
HAC
3B148
MED PREP
3B154
TOILET
3B181
OFFICE
3B149
OFFICE
3B150
LINEN
ROOM,
SOILED
3B152
NOURISHMENT
3B151
NOURISHMENT
3B175
MED PREP
3B176
UTILITY
ROOM,
SOILED
3B178
CORRIDOR
C3-17
CORRIDOR
C3-22
UTILITY
ROOM,
CLEAN
3B130
STORAGE
3B129A
OFFICE
3B177
TOILET,
MALE
3B128
TOILET,
FEMALE
3B126
ELECTRICAL
CLOSET
3B144
TOILET
3B139
CONTROL
CENTER
C3-15
CONTROL
CENTER
C3-25
S1.0-F S1.0-N
S1.0-F
S1.0-F
(C L
E A
R
2' - 0 5/8"
S1.0-F
PLAN AREA
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G
IS
E T
R
ED RA
C H
TI
E C T
Drawing Title
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
FULLY SPRINKLERED
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of Construction and Facilities Management
JPA Project No.
Dwg. of
Renovate TCU-ICU Space Bldg. 330
03/09/2020
DIMENSION PLANS
A101-D3
DWTH
17005.00
552-18-102
Dayton Ohio
GENERAL NOTES
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. All partitions shall be type 'S1.0' unless noted otherwise.
E. See enlarged plans for additional notes.
F. See code plan for existing rated construction. Firestop all new penetrations to maintain integrity of existing rated construction.
Additionally, firestop up to a maximum of 100 penetrations and/or 100 SF of existing, unfirestopped penetrations through existing rated construction.
N Scale: 1/8" = 1'-0"2
DIMENSION PLAN - DEDUCT ALTERNATE #2
N Scale: 1/8" = 1'-0"1
DIMENSION PLAN - DEDUCT ALTERNATE #1
N N.T.S.Scale:
KEY PLAN
Revision s
Date
6 95% Owner Review Resubmittal 11.09.2018
5 95% Owner Review Resubmittal 09.28.2018
4 95% Owner Review Resubmittal 08.20.2018
3 95% Owner Review 06.15.2018
2 Design Development 04.30.2018
1 Schematic Design 02.23.2018
1.2
EDCBA B3 C5 E1
1.5
2.2
3.2
4.1
5.3
4.2
3.1
2.1
D2
4.65
C2 C6
5.2
E9E8
3.05
4.6
CONSULTATION
ROOM
3B102
OFFICE
3B103
OFFICE
3B120
BEDROOM -
RESIDENT
ON-CALL
3B161
CORRIDOR
C3-12
CORRIDOR
C3-14
CORRIDOR
C3-18
CORRIDOR
C3-19
CORRIDOR
C3-20
CORRIDOR
3C-27
CORRIDOR
3C-9
BED ROOM
3B121
RESTROOM
3B121a
RESTROOM
3B122a
BED ROOM
3B122
BED ROOM,
INFECTION
CONTROL
3B123
RESTROOM
3B123a
RESTROOM
3B124a
BED ROOM
3B125
RESTROOM
3B125a
BED ROOM
3B142
RESTROOM
3B142a
RESTROOM
3B140a
BED ROOM
3B140
BARIATRIC,
INFECTION
CONTROL
3B138
RESTROOM
3B138a
RESTROOM
3B137a
BED ROOM,
INFECTION
CONTROL
3B137
BED ROOM,
BARIATRIC
3B135
BED ROOM
3B160
BED ROOM
3B158
BED ROOM,
BARIATRIC
3B110
BED ROOM
3B105
RESTROOM
3B105…
This is the start of the file's text. The full file is on GovTribe.