RFI Form AHS 1 Plumbing.pdf
PDF 77 KB Posted
- Attached to
- Y1DA--Expand First Floor B-1 for PACT - 610-311
- Solicitation number
- 36C25020B0004
About this file
This document is a request for information (RFI) related to a federal contract opportunity for expanding the first floor B-1 for PACT at the Department of Veterans Affairs Northern Indiana Health Care System campus in Fort Wayne, Indiana. The RFI provides project details including specification section references, a request for an underground piping diagram with sizes and routing for an inslab pump pit, and questions regarding the circumference and depth of an existing pit. Responses to the RFI are due by July 22, 2020 and will be addressed through amendments. The related federal contract opportunity is solicitation number 36C25020B0004 for the Y1DA project to expand first floor B-1 for PACT at the VA location.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION (RFI)
36C25020B0004
PROJECT NUMBER: 610-311 Please ensure that before submitting questions or requests for clarification that you thoroughly read the solicitation, specifications, drawings and other pertinent documents. When submitting questions on this project the Government requires contractors to specifically identify the specification and/or solicitation section(s) or drawing number(s) in reference to the question or request for clarification submitted. No question or request for clarification will be answered by the Government unless the above requirements are met. Failure to comply may prevent the Government from responding in a timely manner.
PROJECT TITLE:
(Const) Expand First Floor B-1 for PACT
PROJECT LOCATION:
Department of Veterans Affairs Northern Indiana Health Care System – Fort Wayne Campus 2121 Lake Ave., Fort Wayne, IN
TO:
Yvonne Demorest, Contract Specialist Department of Veterans Affairs NCO10 West Contracting Office 2780 Airport Dr., Suite 340 Columbus, OH 43219 Yvonne.demorest@va.gov
RFI NO.: DATE:
SPEC/DWG. REFERENCE(s):
REPLY NEEDED BY:
INFORMATION NEEDED:
REPLY:
RFIs will be answered by amendment(s).
REPLY FROM: DATE:
ATTACHMENTS: COPY TO:
SUBMITTED BY: CITY/STATE:
PHONE:
A. Hattersley and Sons Fort Wayne IN,
(260) 483-6473
No1 07/22/2020 Plan Sheet PD101 5 Days
Plan Sheet PD101, Column Line WW &24: Indicates to relocate Pit and Duplex Pump and Control.
plan Sheet does not show any under-salb piping.
Please provide a under-slab piping diagram with the pipe routing and pipe size for inslab pump pit..
What is the circumference and the depth of the existing pit?
VHACOSDEMORY1
Highlight
VHACOSDEMORY1
Highlight
VHACOSDEMORY1
Highlight
VHACOSDEMORY1
Highlight
VHACOSDEMORY1
Highlight
File details come from the government source that posted it. Updated .