Drawing_BLDG77_FIRE_FA102_Amdt001.pdf
PDF 408 KB Posted
- Solicitation number
- 36C24921B0018
About this file
This document includes construction drawings and specifications for renovations to Building 77 at the Veterans Affairs Medical Center in Mountain Home, Tennessee. The project involves upgrading the existing fire protection system at the roof level to current NFPA 13 standards, including removing the existing fire alarm smoke detection system. The related federal contract opportunity is solicitation number 36C24921B0018 for renovations to Building 77 to create a new customer service area, with a magnitude of construction between $500,000 and $1,000,000. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S S
S S
S
KEYNOTES:
LH
E 2 1/2" FP-W UP
7 6 5 4
B
C
D
E 2 1/2" FP-W E 2 1/2" FP-W E 2 1/2" FP-W E 2 1/2" FP-W
E
F
P -W
E
F
P -W
E
F
P -W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
1. SEE SHEET F-001 FOR GENERAL NOTES AND LEGEND.
2. FIRE SUPPRESSION SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 13
AND VETERANS AFFAIRS FIRE PROTECTION DESIGN MANUAL. THE ORDER OF
PREFERENCE OF CODE SHALL BE:
1. VAFPDM
2. NFPA 13
3. FIRE SUPPRESSION SYSTEM AT THE ROOF LEVEL IS EXISTING TO REMAIN.
SHEET NOTES:
7 6 5 4
B
C
D
2 3
KEY PLAN
T R
U E
N
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
VAMC MOUNTAIN HOME, TN
B
IM
/1
V A
C u s to m e r
S e rv ic e B
L D
G
/1
V A
B
L D
G
M E
P F
P v
.r v t
/3 /2
:3
:5
P
M
F-102
PARTIAL ROOF FIRE PROTECTION EXISTING
PLANS
RENOVATE BUILDING 77 FOR
CUSTOMER SERVICE
621-20-103
JUNE 23, 2021 NDS BDP
BID DOCUMENTS
1. EXISTING 4" WATER MAIN LOCATED ABOVE THE 3RD FLOOR CEILING SUPPLYING
OVERHEAD SPRINKLER SYSTEM.
2. EXISTING OVERHEAD SPRINKLER SYSTEM SERVES OPEN OFFICE CUBICLES BELOW
THAT ARE NOT PROVIDED WITH CEILINGS.
3. REMOVE THE EXISTING FIRE ALARM SMOKE DETECTION SYSTEM IN ITS ENTIRETY
AT ROOF LEVEL.
SCALE: = 1'-0"
0 4 84
1/4"
SCALE: 1/4" = 1'-0"F1
PARTIAL ROOF FIRE PROTECTION EXISTING PLAN
SCALE: 1/4" = 1'-0"F5
PARTIAL ROOF FIRE PROTECTION EXISTING CEILING PLAN
Revisions: Date:
Revision 1 2021/12/06
| Sheets |
| F-102 - PARTIAL ROOF FIRE PROTECTION EXISTING PLANS |
File details come from the government source that posted it. Updated .