WPB-VA_S-SHEETS.txt
TXT text file 2 KB Posted
- Attached to
- Y1DA--FY23: NRM-Tier 1 (PROJ: 548-23-122) D/B Install Additional Pump on OR Chilled Water Loop
- Solicitation number
- 36C24823R0051_1
About this file
This solicitation and related federal contract opportunity document provide details for an upcoming project at a Department of Veterans Affairs medical facility. The solicitation is a 100% set-aside for Service Disabled Veteran Owned Small Businesses and requests bids for work including installing an additional pump on an existing OR chilled water loop, matching the capacity and controls configuration of two existing pumps. The new pump, VFD, and DDC controls integrated with the facility's BACnet BAS are required. The performance period is 120 days from notice to proceed. Relevant experience with BACnet integration and pumping system installation will be valued.
Text of this file
Transmittal Report:
Created by AutoCAD eTransmit Tuesday, August 17, 2021, 1:48 PM.
Drawing Sheet Set:
This is a transmittal based on drawing sheets from the sheet set:
WPB-VA_S-SHEETS.
Sheets:
S-1 STRUCTURAL NOTES
S-2 PROPOSED PLAN LAYOUT
S-3 STRUCTURAL DETAILS
S-4 EXISTING WALL DEMO AND PROPOSED ELEVATION
S-5 FORMWORK, BATCH AND MIXING SPECIFICATIONS
Files:
Root Drawings: WPB-VA CMU WALL.dwg
Sheet Set Data File:
WPB-VA_S-SHEETS.dst
Sheet Template Files:
sheetsets\architectural imperial.dwt
AutoCAD Drawing (External) References:
X-MOSES ENG BORDER.dwg
X-BASE.dwg
JPG File References:
Textures\Doors - Windows.Wood Doors.Ash.jpg
Adobe Acrobat Document References:
03 30 53.pdf
The following files were excluded from the transmittal:
acad.fmp
Fonts\simplex.shx
Fonts\arial.ttf
Fonts\arialbd.ttf
Fonts\tahoma.ttf
Fonts\ltypeshp.shx
Fonts\romans.shx
Fonts\txt.shx
Fonts\calibri.ttf
Fonts\bold.shx
Fonts\ARIALNB.TTF
Fonts\georgia.ttf
Fonts\ARIALN.TTF
Fonts\wingding.ttf
Fonts\romand.shx
The following files could not be located:
dgnlstyle-lstylebak.(shx,ttf) outline.(shx,ttf)
PlotCfgs\monochrome.ctb
PlotCfgs\JWM-oce.ctb
PlotCfgs\AutoCAD PDF (High Quality Print).pc3
PlotCfgs\DWG To PDF.pc3
ARCHSTYL.(shx,ttf) th5.(shx,ttf)
HAND.(shx,ttf)
PlotCfgs\DWF6 ePlot.pc3
Notes for distribution:
.DWG external reference files:
External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references.
eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted
PDF Underlay files:
Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references.
Material texture files:
Please copy these files to the AutoCAD Texture Maps Search Path directory.
The AutoCAD variable FONTALT was set to:
C:\Users\Stephen\AppData\Roaming\Autodesk\AutoCAD 2020\R23.1\enu\support\simplex.shx
Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font.
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .