This document is a detailed site plan for Parking Lot C, part of the Northport Mill and Fill Project for the Department of Veterans Affairs. The parking lot renovation involves 62,160 square feet with specific infrastructure improvements, including:

Key modifications include new 8-feet sidewalk (1,424 ft²), new striping (130 ft), concrete to black top conversion (640 ft²), one 6-feet ADA curb ramp, two 4-feet ADA curb ramps, and a new crosswalk (135'L x 4'W). The project also requires relocating three existing lighting poles and one fire hydrant, with multiple pricing alternatives for additional work such as new sidewalks, curb replacements, and concrete demolition. The base price covers black top surfacing, ADA ramp installation, and new striping, with optional add alternatives that can be selected to expand the scope of work.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Parking Lot C

Lot Square footage: 62,160 ft2 Curb Linear Feet: 1,160 ft New 8-feet Sidewalk: 1,424 ft2 New Striping: 130 ft Concrete to Black Top Conversion: 640 ft2 New 6-feet ADA Curb Ramp: 1 New 4-feet ADA Curb Ramps: 2 Existing Concrete to be Demolished: 275 ft2 New Crosswalk: 135’L x 4’W New Directional Traffic Arrows: 3

Base Price: Black Top, New ADA 6-feet Ramp, New Striping Add Alternative 1: New Sidewalk, New 4-feet ADA Ramp Add Alternative 2: All Curbs Add Alternative 3: Demolish existing concrete and replace with crosswalk

Relocating (3) lighting poles and (1) fire hydrant

Add Alternative 1: New Sidewalk, New 4-feet ADA Ramp Add Alternative 2: All Curbs Add Alternative 3: Demolish existing concrete and replace with crosswalk

PARKING LOT C

Existing Lighting Pole to be relocated: 3 Existing Fire Hydrant to be relocated: 1

EXISTING FIRE HYDRANT (NOT TO

SCALE) TO BE PULLED BACK 10-FEET

EXISTING LIGHTING POLE (NOT TO SCALE)

TO BE PULLED BACK 10-FEET (TYP OF 3)

VHANOPSINGHS

Highlight

EXISTING LIGHTING POLE (NOT TO SCALE)

TO BE PULLED BACK 10-FEET (TYP OF 3)

VHANOPSINGHS

Highlight

EXISTING FIRE HYDRANT (NOT TO

SCALE) TO BE PULLED BACK 10-FEET

VHANOPSINGHS

Highlight Existing Fire Hydrant to be relocated: 1

VHANOPSINGHS

Highlight xisting Lighting Pole to be relocated: 3

VHANOPSINGHS

Highlight