A-406.pdf
PDF 477 KB Posted
- Attached to
- Z1DA--528-18-109 WARD 9C RENOVATIONS
- Solicitation number
- 36C24222B0069
About this file
This reflected ceiling plan drawing and related federal contract opportunity provide details for a 9th floor renovation at the Buffalo VA Medical Center. Key specifications include installing 2x2 acoustic ceiling tiles and gypsum ceilings throughout various rooms in Area C, coordinating locations for mechanical systems, lighting fixtures, plumbing fixtures, fire sprinklers, and ceiling-mounted patient lift tracks. The federal contract opportunity is a solicitation issued by the Department of Veterans Affairs for project number 528-18-109 to complete the ward 9C renovations at the Buffalo VAMC for a fully sprinklered building. The solicitation number is 36C24222B0069 and offers an opportunity to provide services for the ceiling installation and related construction work as specified in the reflected ceiling plan drawings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AA-102.pdf | ||
| AD-102.pdf | ||
| A-604.pdf | ||
| A-405.pdf | ||
| AA-101.pdf | ||
| A-404.pdf | ||
| AD-100.pdf | ||
| AA-100.pdf | ||
| A-109.pdf | ||
| 117300.pdf | ||
| A-108.pdf | ||
| 36C24222B0069 0005.docx | DOCX document | |
| 36C24222B0069 0004.docx | DOCX document | |
| Abatement Ward 9c Report.pdf | ||
| 36C24222B0069 0003.docx | DOCX document | |
| 36C24222B0069 0002.docx | DOCX document | |
| 36C24222B0069 0001.docx | DOCX document | |
| 528-18-109 Pre Bid Attendance.pdf | ||
| SPECS 3.pdf | ||
| 36C24222B0069_1.docx | DOCX document | |
| SPECS 1.pdf | ||
| WAGE RATE.pdf | ||
| LIMITATION ON SUBCONTRACTING.docx | DOCX document | |
| SPECS 2.pdf | ||
| 528-18-109_9C DRAWINGS.pdf | ||
| FAR 52.225-2 Buy American Certification.docx | DOCX document |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S
OS
C B A
DD
C.1
5.1
CC
BB
AA
AREA 'A'
AREA 'C'
MATCHLINE
A R
E A
B
A R
E A
C
M
A T
C H
L
IN
E
AREA 'A'
AREA 'B'
STAIR
NO WORK
2' -6
/4
A-504
LARGE
EQUIP.
RM.
908C
PATIENT
ROOM
904C
CORRIDOR
900C
HSKPG
934C
DATA RM
933C
PATIENT
ROOM
932C
TLT. RM.
932-1C
TLT. RM.
931-1C
PATIENT
ROOM
931C
PATIENT
ROOM
905C
TLT. RM.
905-1C
TLT. RM.
904-1C
CLEAN
UTILITY
906C
SOILED
UTILITY
907C
CLEAN
LINEN
929C
NURSE
MANAGER
930C
N.STN.
930C-1
7'-6"
7'-6"
8'-0"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
8'-11"
8'-11"
8'-11"
8'-11"
8'-11"
8'-11"
8'-11"
8'-11"
9'-0"
8'-0"
8'-0"
7'-6"
7'-8"
7'-6"
B
DD
C.1
5.1
CC
BB
AA
B
DD
C.1
5.1
CC
BB
AA
C B A
DD
C.1
5.1
CC
BB
AA
9'-0"
3'
/8
10' - 10 7/8"
4'
1/
8"
4'
1/
8"
4'
1/
8"
4'
1/
8"
3'
/8
3'
/8
/8
3'
/8
7' - 6"
7' - 0"
9B
9B
GENERAL CEILING NOTES - 9C
A. CONTRACTOR TO VERIFY DIMENSIONS IN FIELD PRIOR TO THE START OF CONSTRUCTION.
B. REFER TO MECHANICAL, ELECTRICAL AND FIRE PROTECTION WORK FOR CEILING MOUNTED DEVICES AND
LOCATIONS. SHOWN HERE FOR COORDINATION ONLY.
C. PRIME AND PAINT EXPOSED SURFACES OF GYPSUM SOFFIT / CEILING CONSTRUCTION - REFER TO ROOM
FINISH SCHEDULE.
D. PROVIDE BLOCKING FOR ANCHORING OF CEILING SUSPENSION SYSTEMS AS REQUIRED.
E. COORDINATE FINAL CEILING HEIGHTS AND MINIMUM REQUIRED CLEARANCES WITH WORK TO BE CONCEALED
ABOVE CEILING.
F. CONTRACTOR TO SUBMIT COORDINATION SHOP DRAWINGS FORE REVIEW AND RECEIVE APPROVAL PRIOR TO COMMENCEMENT OF WORK. COORDINATION DRAWINGS TO SHOW PLAN LOCATIONS AND ELEVATIONS OF HVAC, ELECTRICAL, PLUMBING, FIRE PROTECTION, MEDICAL GAS, STRUCTURAL, AND CEILINGS SYSTEMS.
G. REFER TO ROOM FINISH SCHEDULE ON SHEET A-603 FOR DETAILS REGARDING CEILING FINISHES.
H. EXISTING TO REMAIN TILE AND GRID AT ENTRY DAMAGED BY CONTRACTOR SHALL BE REPLACED IN-KIND.
I. CONTRACTOR IS EXPECTED TO BECOME FAMILIAR WITH MECHANICAL, ELECTRICAL, PLUMBING EQUIPMENT, DEVICE LOCATIONS, AND LAYOUTS PRIOR TO THE START OF THE CEILING INSTALLATION.
J. CONTRACTOR SHALL EXERT CARE WHEN DRILLING INTO SLAB ABOVE AS EXISTING ELECTRICAL CONDUIT ARE
BURIED IN THE SLAB ABOVE AND LOCATIONS ARE UNKNOWN.
K. CONTACT COR PROMPTLY IF REINFORCING BAR IS DAMAGED WHILE DRILLING INTO SLAB ABOVE.
L. IN PATIENT ROOMS, CENTER LIGHT FIXTURE ABOVE PLANNED BED LOCATION. CONFORM CEILING GRID TO
ACCOMMODATE.
M. ANCHORING OF ITEMS TO THE UNDERSIDE OF BEAMS IS STRICTLY PROHIBITED, INCLUDING CONDUIT, PLUMBING, DUCTWORK, TRACK, AND OTHER SIMILAR MATERIALS/SYSTEMS.
24" x 24" ACOUSTIC CEILING TILE
GYPSUM SOFFIT TO BE PAINTED
LED LIGHT FIXTURE.
COORDINATE WITH LIGHTING
DRAWINGS
HVAC. COORDINATE WITH HVAC
DRAWINGS
TOILET ROOM VENT
LIGHT FIXTURES. COORDINATE
WITH ELECTRICAL DRAWINGS
FIRE PROTECTION SPRINKLER
SYSTEM. COORDINATE WITH FIRE
PROTECTION DRAWINGS
EMERGENCY EXIT SIGN.
COORDINATE WITH LIGHTING
DRAWINGS
MECHANICAL VALANCE UNIT,
REFER TO HVAC DRAWINGS
WALL MOUNTED MECHANICAL
DIFFUSER, COORDINATE WITH
HVAC DRAWINGS
PATIENT LIFT RAIL
CUBICLE CURTAIN TRACK
X'-X" CEILING HEIGHT
REFLECTED CEILING PLAN LEGEND
NOTE: NOT ALL SYMBOLS MAY
BE USED IN EACH DRAWING
1 AT-1 2x2 ACOUSTIC CEILING TILE
2 AT-2 2x2 ACOUSTIC CEILING TILE @ TOILET ROOMS
3 GYPSUM CEILING - P-1
CEILING TYPE LEGEND
DRAWING NOTE
1. PATIENT LIFTS ARE INCLUDED IN THE SCOPE OF WORK, COORDINATE LOCATION OF CEILING MOUNTED TRACKS WITH ALL TRADES. PATIENT ROOMS 904C AND 905C ARE TO BE PROVIDED MOBILE FLOOR LIFTS AS CEILING MOUNTED LIFTS ARE NOT POSSIBLE DUE TO EXISTING ABOVE CEILING CONDITIONS; MOBILE LIFTS ARE TO MEET WEIGHT REQUIREMENTS LISTED IN SPECIFICATION SECTION 117300 – CEILING MOUNTED PATIENT LIFT SYSTEMS
2. PNEUMATIC TUBE SYSTEM IS N.I.C. CONTRACTOR SHALL COORDINATE FOR INSTALLATION BY OTHERS DURING
CONTRACT PERIOD. REFER TO COR FOR SCHEDULING.
AREA 'C'
KEY PLAN
WING 9C
95 Perry Street, Suite 300 Buffalo, NY 14203
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT: WARD 9C RENOVATIONS
3495 BAILEY AVENUE BUFFALO, NY 14215
528-18-109
528-18-109-
B
IM
/B u ff a lo
V A
W a rd
C
R e d e s ig n
C o n s tr u c ti o n /1
A R
C H
.r v t
/2 /2
:0
:3
A
M
A-406
9TH FLOOR - PARTIAL CEILING
PLAN - AREA 'C'
February 25, 2022 RAS AHE
1/4" = 1'-0"1
9TH FLOOR - AREA 'C'
0' 2' 4' 8' 16'
1/4" = 1'-0"
NORTH
Revisions: Date:
BID ADDENDUM #1 2022/10/28
| Sheets |
| A-108 - 7C REFLECTED CEILING PLAN |
| A-109 - 8C REFLECTED CEILING PLAN |
| A-404 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'A' |
| A-405 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'B' |
| A-406 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'C' |
| A-604 - EQUIPMENT SCHEDULE |
| AD-100 - 7TH FLOOR DEMOLITION CEILING PLAN |
| AD-102 - 8TH FLOOR DEMOLITION CEILING PLAN |