A-108.pdf

PDF 200 KB Posted

Attached to
Z1DA--528-18-109 WARD 9C RENOVATIONS
Solicitation number
36C24222B0069
Issued by

About this file

This document contains reflected ceiling plans and specifications for renovations to Ward 9C at the Buffalo VA Medical Center. The plans call for reinstalling an existing 24" by 48" acoustic panel ceiling system to match areas that were previously stored, including replacing any damaged tiles or grid. Light fixtures and other devices mounted in the ceiling will also be reinstalled according to their original locations. Priming and painting will be required for exposed gypsum surfaces. Strict prohibitions are outlined regarding anchoring items to the underside of beams. The related federal contract opportunity is solicitation number 36C24222B0069 for the Ward 9C Renovations project at the Buffalo VAMC, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2. The opportunity type is a solicitation for this renovation work.

View the file

Other files

File Type Posted
AA-102.pdf PDF
A-406.pdf PDF
AD-102.pdf PDF
A-604.pdf PDF
A-405.pdf PDF
AA-101.pdf PDF
A-404.pdf PDF
AD-100.pdf PDF
AA-100.pdf PDF
A-109.pdf PDF
117300.pdf PDF
36C24222B0069 0005.docx DOCX document
36C24222B0069 0004.docx DOCX document
Abatement Ward 9c Report.pdf PDF
36C24222B0069 0003.docx DOCX document
36C24222B0069 0002.docx DOCX document
36C24222B0069 0001.docx DOCX document
528-18-109 Pre Bid Attendance.pdf PDF
SPECS 3.pdf PDF
36C24222B0069_1.docx DOCX document
SPECS 1.pdf PDF
WAGE RATE.pdf PDF
LIMITATION ON SUBCONTRACTING.docx DOCX document
SPECS 2.pdf PDF
528-18-109_9C DRAWINGS.pdf PDF
FAR 52.225-2 Buy American Certification.docx DOCX document
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F 9

D C B A

DD

C.1

5.1

EFGH

CC

BB

AA

PATCH GWB AT AREA OF REMOVAL. PRIME AND PAINT TO MATCH.

GENERAL CEILING NOTES - 7C & 8C

A. CONTRACTOR TO VERIFY DIMENSIONS IN FIELD PRIOR TO THE START OF CONSTRUCTION.

B. REINSTALL STORED ACOUSTIC PANEL CEILING SYSTEM AS INDICATED; DAMAGED TILE AND/OR GRID SHALL BE REPLACED IN KIND. CAREFULLY REINSTALL AND REPLACE THE SYSTEM SO CONTIGUOUS AREAS MATCH

IN STYLE, FINISH AND COLOR.

C. SEE MECHANICAL, ELECTRICAL, AND FIRE PROTECTION WORK FOR LOCATIONS OF AND REQUIREMENTS

FOR REINSTALLED CEILING MOUNTED DEVICES AND LOCATIONS.

D. CONTRACTOR SHALL EXERT CARE WHEN DRILLING INTO SLAB ABOVE AS EXISTING ELECTRICAL CONDUIT

ARE BURIED IN SLAB ABOVE AND LOCATIONS ARE UNKNOWN.

E. CONTACT COR PROMPTLY IF REINFORCING BAR IS DAMAGED WHILE DRILLING INTO SLAB ABOVE.

F. PRIME AND PAINT EXPOSED SURFACES OF GYPSUM SOFFIT / CEILING CONSTRUCTION IN AFFECTED AREAS.

G. BLOCKING IS REQUIRED FOR ANCHORAGE OF CEILING SUSPENSION SYSTEMS.

H. COLUMN ENCLOSURES ARE EXISTING, 2 HOUR FIRE RATED SYSTEMS. WHERE THE INTEGRITY OF THE SYSTEM IS DISRUPTED BY CONSTRUCTION ACTIVITIES, RECONSTRUCT ENCLOSURE PER 2/A-108. FIRE CAULK UNDERSIDE OF CONCRETE DECK AND ANY JOINTS. SHOULD ANY CONDITIONS PERMANENTLY

DISRUPT THE INTEGRITY OF THE FIRE RATED CONSTRUCTION, NOTIFY THE COR PROMPTLY.

I. ANCHORING OF ITEMS TO THE UNDERSIDE OF BEAMS IS STRICTLY PROHIBITED, INCLUDING CONDUIT, PLUMBING, DUCTWORK, TRACK AND OTHER SIMILAR MATERIALS/SYSTEMS.

REINSTALL EXISTING STORED 24" x 48"

ACOUSTICAL PANEL CEILING SYSTEM

LEGEND

24" x 48" ACOUSTICAL PANEL CEILING

SYSTEM TO MATCH EXISTING

GYPSUM WALLBOARD

REINSTALL EXISTING STORED LIGHT

FIXTURE. REFER TO ELECTRICAL DRAWINGS

LIGHT FIXTURE. REFER TO ELECTRICAL

DRAWINGS FOR FIXTURE TYPE

C

B A

D

KEY PLAN

95 Perry Street, Suite 300 Buffalo, NY 14203

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ARCHITECT: WARD 9C RENOVATIONS

3495 BAILEY AVENUE BUFFALO, NY 14215

528-18-109

528-18-109-

B

IM

/B u ff a lo

V A

W a rd

C

R e d e s ig n

C o n s tr u c ti o n /1

A R

C H

.r v t

/2 /2

:0

:1

A

M

A-108

7C REFLECTED CEILING PLAN

February 25, 2022 RAS RLB

1/8" = 1'-0"1

7TH FLOOR REFLECTED CEILING PLAN

NORTH

1/8" = 1'-0"

0' 4' 8' 16' 32'

Revisions: Date:

BID ADDENDUM #1 2022/10/28

Sheets
A-108 - 7C REFLECTED CEILING PLAN
A-109 - 8C REFLECTED CEILING PLAN
A-404 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'A'
A-405 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'B'
A-406 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'C'
A-604 - EQUIPMENT SCHEDULE
AD-100 - 7TH FLOOR DEMOLITION CEILING PLAN
AD-102 - 8TH FLOOR DEMOLITION CEILING PLAN

File details come from the government source that posted it. Updated .