A-108.pdf
PDF 200 KB Posted
- Attached to
- Z1DA--528-18-109 WARD 9C RENOVATIONS
- Solicitation number
- 36C24222B0069
About this file
This document contains reflected ceiling plans and specifications for renovations to Ward 9C at the Buffalo VA Medical Center. The plans call for reinstalling an existing 24" by 48" acoustic panel ceiling system to match areas that were previously stored, including replacing any damaged tiles or grid. Light fixtures and other devices mounted in the ceiling will also be reinstalled according to their original locations. Priming and painting will be required for exposed gypsum surfaces. Strict prohibitions are outlined regarding anchoring items to the underside of beams. The related federal contract opportunity is solicitation number 36C24222B0069 for the Ward 9C Renovations project at the Buffalo VAMC, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2. The opportunity type is a solicitation for this renovation work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AA-102.pdf | ||
| A-406.pdf | ||
| AD-102.pdf | ||
| A-604.pdf | ||
| A-405.pdf | ||
| AA-101.pdf | ||
| A-404.pdf | ||
| AD-100.pdf | ||
| AA-100.pdf | ||
| A-109.pdf | ||
| 117300.pdf | ||
| 36C24222B0069 0005.docx | DOCX document | |
| 36C24222B0069 0004.docx | DOCX document | |
| Abatement Ward 9c Report.pdf | ||
| 36C24222B0069 0003.docx | DOCX document | |
| 36C24222B0069 0002.docx | DOCX document | |
| 36C24222B0069 0001.docx | DOCX document | |
| 528-18-109 Pre Bid Attendance.pdf | ||
| SPECS 3.pdf | ||
| 36C24222B0069_1.docx | DOCX document | |
| SPECS 1.pdf | ||
| WAGE RATE.pdf | ||
| LIMITATION ON SUBCONTRACTING.docx | DOCX document | |
| SPECS 2.pdf | ||
| 528-18-109_9C DRAWINGS.pdf | ||
| FAR 52.225-2 Buy American Certification.docx | DOCX document |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F 9
D C B A
DD
C.1
5.1
EFGH
CC
BB
AA
PATCH GWB AT AREA OF REMOVAL. PRIME AND PAINT TO MATCH.
GENERAL CEILING NOTES - 7C & 8C
A. CONTRACTOR TO VERIFY DIMENSIONS IN FIELD PRIOR TO THE START OF CONSTRUCTION.
B. REINSTALL STORED ACOUSTIC PANEL CEILING SYSTEM AS INDICATED; DAMAGED TILE AND/OR GRID SHALL BE REPLACED IN KIND. CAREFULLY REINSTALL AND REPLACE THE SYSTEM SO CONTIGUOUS AREAS MATCH
IN STYLE, FINISH AND COLOR.
C. SEE MECHANICAL, ELECTRICAL, AND FIRE PROTECTION WORK FOR LOCATIONS OF AND REQUIREMENTS
FOR REINSTALLED CEILING MOUNTED DEVICES AND LOCATIONS.
D. CONTRACTOR SHALL EXERT CARE WHEN DRILLING INTO SLAB ABOVE AS EXISTING ELECTRICAL CONDUIT
ARE BURIED IN SLAB ABOVE AND LOCATIONS ARE UNKNOWN.
E. CONTACT COR PROMPTLY IF REINFORCING BAR IS DAMAGED WHILE DRILLING INTO SLAB ABOVE.
F. PRIME AND PAINT EXPOSED SURFACES OF GYPSUM SOFFIT / CEILING CONSTRUCTION IN AFFECTED AREAS.
G. BLOCKING IS REQUIRED FOR ANCHORAGE OF CEILING SUSPENSION SYSTEMS.
H. COLUMN ENCLOSURES ARE EXISTING, 2 HOUR FIRE RATED SYSTEMS. WHERE THE INTEGRITY OF THE SYSTEM IS DISRUPTED BY CONSTRUCTION ACTIVITIES, RECONSTRUCT ENCLOSURE PER 2/A-108. FIRE CAULK UNDERSIDE OF CONCRETE DECK AND ANY JOINTS. SHOULD ANY CONDITIONS PERMANENTLY
DISRUPT THE INTEGRITY OF THE FIRE RATED CONSTRUCTION, NOTIFY THE COR PROMPTLY.
I. ANCHORING OF ITEMS TO THE UNDERSIDE OF BEAMS IS STRICTLY PROHIBITED, INCLUDING CONDUIT, PLUMBING, DUCTWORK, TRACK AND OTHER SIMILAR MATERIALS/SYSTEMS.
REINSTALL EXISTING STORED 24" x 48"
ACOUSTICAL PANEL CEILING SYSTEM
LEGEND
24" x 48" ACOUSTICAL PANEL CEILING
SYSTEM TO MATCH EXISTING
GYPSUM WALLBOARD
REINSTALL EXISTING STORED LIGHT
FIXTURE. REFER TO ELECTRICAL DRAWINGS
LIGHT FIXTURE. REFER TO ELECTRICAL
DRAWINGS FOR FIXTURE TYPE
C
B A
D
KEY PLAN
95 Perry Street, Suite 300 Buffalo, NY 14203
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT: WARD 9C RENOVATIONS
3495 BAILEY AVENUE BUFFALO, NY 14215
528-18-109
528-18-109-
B
IM
/B u ff a lo
V A
W a rd
C
R e d e s ig n
C o n s tr u c ti o n /1
A R
C H
.r v t
/2 /2
:0
:1
A
M
A-108
7C REFLECTED CEILING PLAN
February 25, 2022 RAS RLB
1/8" = 1'-0"1
7TH FLOOR REFLECTED CEILING PLAN
NORTH
1/8" = 1'-0"
0' 4' 8' 16' 32'
Revisions: Date:
BID ADDENDUM #1 2022/10/28
| Sheets |
| A-108 - 7C REFLECTED CEILING PLAN |
| A-109 - 8C REFLECTED CEILING PLAN |
| A-404 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'A' |
| A-405 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'B' |
| A-406 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'C' |
| A-604 - EQUIPMENT SCHEDULE |
| AD-100 - 7TH FLOOR DEMOLITION CEILING PLAN |
| AD-102 - 8TH FLOOR DEMOLITION CEILING PLAN |
File details come from the government source that posted it. Updated .