This document includes ceiling plans and specifications for the 9C Renovation project at the Buffalo VA Medical Center. Key details include reflected ceiling plans for areas A, B, and C on the 9th floor showing layouts of acoustic ceiling tiles, gypsum ceilings, lighting fixtures, HVAC systems, sprinklers, and other mechanical features. Specifications note ceiling material types, heights, finishes, blocking requirements, and coordination responsibilities between trades. The related federal contract opportunity is solicitation number 36C24222B0069 for the Ward 9C Renovations project at the Buffalo VAMC, a project overseen by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2.

View the file

Other files

File Type Posted
AA-102.pdf PDF
A-406.pdf PDF
AD-102.pdf PDF
A-604.pdf PDF
AA-101.pdf PDF
A-404.pdf PDF
AD-100.pdf PDF
AA-100.pdf PDF
A-109.pdf PDF
117300.pdf PDF
A-108.pdf PDF
36C24222B0069 0005.docx DOCX document
36C24222B0069 0004.docx DOCX document
Abatement Ward 9c Report.pdf PDF
36C24222B0069 0003.docx DOCX document
36C24222B0069 0002.docx DOCX document
36C24222B0069 0001.docx DOCX document
528-18-109 Pre Bid Attendance.pdf PDF
SPECS 3.pdf PDF
36C24222B0069_1.docx DOCX document
SPECS 1.pdf PDF
WAGE RATE.pdf PDF
LIMITATION ON SUBCONTRACTING.docx DOCX document
SPECS 2.pdf PDF
528-18-109_9C DRAWINGS.pdf PDF
FAR 52.225-2 Buy American Certification.docx DOCX document
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S

S D

S D

S D

OS

OS

OS

OS

D C

DD

C.1

5.1

EFGH

A R

EA

'A

A R

EA

'B

M

ATC

H

LIN

E

STAIR

NO

WORK

A R

E A

B

A R

E A

C

M

A T

C H

L

IN

E

AREA 'A'

AREA 'C'

NURSE

STATION

918C

CONF.

RM /

RESIDENT

OFFICE

917C

MED RM

920C

PATIENT

ROOM -

IIA/BAR.

914C

TLT. RM.

- BAR

914-1C

PATIENT

ROOM -

IIA

913C

ANTE

RM.

912C

TLT. RM.

-IIA

913-1C

PATIENT

ROOM -

IIA

911C

TLT. RM.

-IIA

911-1C

N. STN.

910C

CORRIDOR

900C

PATIENT

ROOM -

IIA/BAR.

916C

ANTE

RM.

915C

PATIENT

ROOM

909C

TLT. RM.

909-1C

LARGE

EQUIP.

RM.

908C

TLT. RM.

- BAR

916-1C

SOILED

UTILITY

907C

7'-6"

8'-0"

8'-11"

8'-8"

8'-11"

8'-11"

8'-8"

8'-11"

8'-11"

8'-0"

9'-0"

8'-11"

8'-11"

8'-11"

8'-11"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6" 3

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

8'-0"

9'-0"

8'-0"

7'-8"

7'-6"

7'-6"

8'-11"

D C

DD

C.1

EFGH

D C

DD

C.1

EFGH

D C

DD

C.1

5.1

EFGH

9'-0"

8'-11"

/8

/8

/8

/8

3' - 6 7/8"

/8

/2

/8

/4

/4

4' - 1 1/8"

7' - 6"

7' - 6"

9B

9B

9 9 9 9 9 9

9B 9 9 9B

9B

2' - 8" 6"

GENERAL CEILING NOTES - 9C

A. CONTRACTOR TO VERIFY DIMENSIONS IN FIELD PRIOR TO THE START OF CONSTRUCTION.

B. REFER TO MECHANICAL, ELECTRICAL AND FIRE PROTECTION WORK FOR CEILING MOUNTED DEVICES AND

LOCATIONS. SHOWN HERE FOR COORDINATION ONLY.

C. PRIME AND PAINT EXPOSED SURFACES OF GYPSUM SOFFIT / CEILING CONSTRUCTION - REFER TO ROOM

FINISH SCHEDULE.

D. PROVIDE BLOCKING FOR ANCHORING OF CEILING SUSPENSION SYSTEMS AS REQUIRED.

E. COORDINATE FINAL CEILING HEIGHTS AND MINIMUM REQUIRED CLEARANCES WITH WORK TO BE CONCEALED

ABOVE CEILING.

F. CONTRACTOR TO SUBMIT COORDINATION SHOP DRAWINGS FORE REVIEW AND RECEIVE APPROVAL PRIOR TO COMMENCEMENT OF WORK. COORDINATION DRAWINGS TO SHOW PLAN LOCATIONS AND ELEVATIONS OF HVAC, ELECTRICAL, PLUMBING, FIRE PROTECTION, MEDICAL GAS, STRUCTURAL, AND CEILINGS SYSTEMS.

G. REFER TO ROOM FINISH SCHEDULE ON SHEET A-603 FOR DETAILS REGARDING CEILING FINISHES.

H. EXISTING TO REMAIN TILE AND GRID AT ENTRY DAMAGED BY CONTRACTOR SHALL BE REPLACED IN-KIND.

I. CONTRACTOR IS EXPECTED TO BECOME FAMILIAR WITH MECHANICAL, ELECTRICAL, PLUMBING EQUIPMENT, DEVICE LOCATIONS, AND LAYOUTS PRIOR TO THE START OF THE CEILING INSTALLATION.

J. CONTRACTOR SHALL EXERT CARE WHEN DRILLING INTO SLAB ABOVE AS EXISTING ELECTRICAL CONDUIT ARE

BURIED IN THE SLAB ABOVE AND LOCATIONS ARE UNKNOWN.

K. CONTACT COR PROMPTLY IF REINFORCING BAR IS DAMAGED WHILE DRILLING INTO SLAB ABOVE.

L. IN PATIENT ROOMS, CENTER LIGHT FIXTURE ABOVE PLANNED BED LOCATION. CONFORM CEILING GRID TO

ACCOMMODATE.

M. ANCHORING OF ITEMS TO THE UNDERSIDE OF BEAMS IS STRICTLY PROHIBITED, INCLUDING CONDUIT, PLUMBING, DUCTWORK, TRACK, AND OTHER SIMILAR MATERIALS/SYSTEMS.

1 AT-1 2x2 ACOUSTIC CEILING TILE

2 AT-2 2x2 ACOUSTIC CEILING TILE @ TOILET ROOMS

3 GYPSUM CEILING - P-1

CEILING TYPE LEGEND

24" x 24" ACOUSTIC CEILING TILE

GYPSUM SOFFIT TO BE PAINTED

LED LIGHT FIXTURE.

COORDINATE WITH LIGHTING

DRAWINGS

HVAC. COORDINATE WITH HVAC

DRAWINGS

TOILET ROOM VENT

LIGHT FIXTURES. COORDINATE

WITH ELECTRICAL DRAWINGS

FIRE PROTECTION SPRINKLER

SYSTEM. COORDINATE WITH FIRE

PROTECTION DRAWINGS

EMERGENCY EXIT SIGN.

COORDINATE WITH LIGHTING

DRAWINGS

MECHANICAL VALANCE UNIT,

REFER TO HVAC DRAWINGS

WALL MOUNTED MECHANICAL

DIFFUSER, COORDINATE WITH

HVAC DRAWINGS

PATIENT LIFT RAIL

CUBICLE CURTAIN TRACK

X'-X" CEILING HEIGHT

REFLECTED CEILING PLAN LEGEND

NOTE: NOT ALL SYMBOLS MAY

BE USED IN EACH DRAWING

DRAWING NOTE

1. PATIENT LIFTS ARE INCLUDED IN THE SCOPE OF WORK, COORDINATE LOCATION OF CEILING MOUNTED TRACKS WITH ALL TRADES. PATIENT ROOMS 904C AND 905C ARE TO BE PROVIDED MOBILE FLOOR LIFTS AS CEILING MOUNTED LIFTS ARE NOT POSSIBLE DUE TO EXISTING ABOVE CEILING CONDITIONS; MOBILE LIFTS ARE TO MEET WEIGHT REQUIREMENTS LISTED IN SPECIFICATION SECTION 117300 – CEILING MOUNTED PATIENT LIFT SYSTEMS

2. PNEUMATIC TUBE SYSTEM IS N.I.C. CONTRACTOR SHALL COORDINATE FOR INSTALLATION BY OTHERS DURING

CONTRACT PERIOD. REFER TO COR FOR SCHEDULING.

AREA 'B'

KEY PLAN

WING 9C

95 Perry Street, Suite 300 Buffalo, NY 14203

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ARCHITECT: WARD 9C RENOVATIONS

3495 BAILEY AVENUE BUFFALO, NY 14215

528-18-109

528-18-109-

B

IM

/B u ff a lo

V A

W a rd

C

R e d e s ig n

C o n s tr u c ti o n /1

A R

C H

.r v t

/2 /2

:0

:3

A

M

A-405

9TH FLOOR - PARTIAL CEILING

PLAN - AREA 'B'

February 25, 2022 RAS AHE

1/4" = 1'-0"1

9TH FLOOR - AREA 'B'

0' 2' 4' 8' 16'

1/4" = 1'-0"

NORTH

Revisions: Date:

BID ADDENDUM #1 2022/10/28

Sheets
A-108 - 7C REFLECTED CEILING PLAN
A-109 - 8C REFLECTED CEILING PLAN
A-404 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'A'
A-405 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'B'
A-406 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'C'
A-604 - EQUIPMENT SCHEDULE