A-404.pdf
PDF 642 KB Posted
- Attached to
- Z1DA--528-18-109 WARD 9C RENOVATIONS
- Solicitation number
- 36C24222B0069
About this file
This document package includes ceiling plan drawings and specifications for renovation work at the Buffalo VA Medical Center Ward 9C, as well as details of the related federal contract opportunity. The drawings provide layout details for ceiling, lighting, HVAC and other systems on the 7th through 9th floors, including room dimensions and finishes. The contract opportunity is solicited by the Department of Veterans Affairs for renovations to Ward 9C at the Buffalo VAMC, including fully sprinklering the area, with an estimated value of $528,180.09. The solicitation number is 36C24222B0069 and responses are due on unspecified dates. The incumbent contractor and award dates are not provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AA-102.pdf | ||
| A-406.pdf | ||
| AD-102.pdf | ||
| A-604.pdf | ||
| A-405.pdf | ||
| AA-101.pdf | ||
| AD-100.pdf | ||
| AA-100.pdf | ||
| A-109.pdf | ||
| 117300.pdf | ||
| A-108.pdf | ||
| 36C24222B0069 0005.docx | DOCX document | |
| 36C24222B0069 0004.docx | DOCX document | |
| Abatement Ward 9c Report.pdf | ||
| 36C24222B0069 0003.docx | DOCX document | |
| 36C24222B0069 0002.docx | DOCX document | |
| 36C24222B0069 0001.docx | DOCX document | |
| 528-18-109 Pre Bid Attendance.pdf | ||
| SPECS 3.pdf | ||
| 36C24222B0069_1.docx | DOCX document | |
| SPECS 1.pdf | ||
| WAGE RATE.pdf | ||
| LIMITATION ON SUBCONTRACTING.docx | DOCX document | |
| SPECS 2.pdf | ||
| 528-18-109_9C DRAWINGS.pdf | ||
| FAR 52.225-2 Buy American Certification.docx | DOCX document |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S
S
S
S
S D
S D
S D
OS
OS
OS
OS
OS
D C B A
DD
5.1
E
STAIR
NO
WORK
AREA 'A'
AREA 'C'
MATCHLINE
A R
E A
B
A R
E A
C
M
A T
C H
L
IN
E
A R
EA
'A
A R
EA
'B
A-501
PATCH, PRIME
& PAINT
PATIENT
ROOM
924C
PATIENT
ROOM
923C
TLT. RM.
923-1C
TLT. RM.
924-1C
CORRIDOR
900C
PATIENT
ROOM
926C
TLT. RM.
926-1C
TLT. RM.
925-1C
PATIENT
ROOM
925C
PATIENT
ROOM
921C
NURSE
STATION
918C
CONF.
RM /
RESIDENT
OFFICE
917C
PATIENT
LOUNGE
928C
N.WK.RM
927C
N.TR.
927-1C
TLT. RM.
921-1C
CRASH
CART
922C
MED RM
920C
CLEAN
LINEN
929C
9'-0"
8'-11"
8'-11"
8'-11"
8'-11"
9'-0"
8'-0"
9'-0"
9'-0"
8'-0"
7'-8"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-0"
7'-6"
8'-11"
8'-8"
8'-11"
8'-11"
8'-11"
8'-11"
D C B A
DD
5.1
E
11 10 9
D C B A
DD
5.1
E
11 10 9
D C B A
DD
5.1
E
11 10 9
4' - 1 1/8" 4' - 1 1/8"
4' - 1 1/8"
4' - 1 1/8"
4' - 1 1/8"
4' - 1 1/8"
4' - 1 1/8"
3' - 8 3/4"
2' - 6 3/8"
4' - 1 1/8"
/8
7' - 6"
7' - 6"
7' - 6"
7' - 6"
9B
9B
9 9
9B
9B
8'-11"
24" x 24" ACOUSTIC CEILING TILE
GYPSUM SOFFIT TO BE PAINTED
LED LIGHT FIXTURE.
COORDINATE WITH LIGHTING
DRAWINGS
HVAC. COORDINATE WITH HVAC
DRAWINGS
TOILET ROOM VENT
LIGHT FIXTURES. COORDINATE
WITH ELECTRICAL DRAWINGS
FIRE PROTECTION SPRINKLER
SYSTEM. COORDINATE WITH FIRE
PROTECTION DRAWINGS
EMERGENCY EXIT SIGN.
COORDINATE WITH LIGHTING
DRAWINGS
MECHANICAL VALANCE UNIT,
REFER TO HVAC DRAWINGS
WALL MOUNTED MECHANICAL
DIFFUSER, COORDINATE WITH
HVAC DRAWINGS
PATIENT LIFT RAIL
CUBICLE CURTAIN TRACK
X'-X" CEILING HEIGHT
REFLECTED CEILING PLAN LEGEND
NOTE: NOT ALL SYMBOLS MAY
BE USED IN EACH DRAWING
1 AT-1 2x2 ACOUSTIC CEILING TILE
2 AT-2 2x2 ACOUSTIC CEILING TILE @ TOILET ROOMS
3 GYPSUM CEILING - P-1
CEILING TYPE LEGEND
GENERAL CEILING NOTES - 9C
A. CONTRACTOR TO VERIFY DIMENSIONS IN FIELD PRIOR TO THE START OF CONSTRUCTION.
B. REFER TO MECHANICAL, ELECTRICAL AND FIRE PROTECTION WORK FOR CEILING MOUNTED DEVICES AND
LOCATIONS. SHOWN HERE FOR COORDINATION ONLY.
C. PRIME AND PAINT EXPOSED SURFACES OF GYPSUM SOFFIT / CEILING CONSTRUCTION - REFER TO ROOM
FINISH SCHEDULE.
D. PROVIDE BLOCKING FOR ANCHORING OF CEILING SUSPENSION SYSTEMS AS REQUIRED.
E. COORDINATE FINAL CEILING HEIGHTS AND MINIMUM REQUIRED CLEARANCES WITH WORK TO BE CONCEALED
ABOVE CEILING.
F. CONTRACTOR TO SUBMIT COORDINATION SHOP DRAWINGS FORE REVIEW AND RECEIVE APPROVAL PRIOR TO COMMENCEMENT OF WORK. COORDINATION DRAWINGS TO SHOW PLAN LOCATIONS AND ELEVATIONS OF HVAC, ELECTRICAL, PLUMBING, FIRE PROTECTION, MEDICAL GAS, STRUCTURAL, AND CEILINGS SYSTEMS.
G. REFER TO ROOM FINISH SCHEDULE ON SHEET A-603 FOR DETAILS REGARDING CEILING FINISHES.
H. EXISTING TO REMAIN TILE AND GRID AT ENTRY DAMAGED BY CONTRACTOR SHALL BE REPLACED IN-KIND.
I. CONTRACTOR IS EXPECTED TO BECOME FAMILIAR WITH MECHANICAL, ELECTRICAL, PLUMBING EQUIPMENT, DEVICE LOCATIONS, AND LAYOUTS PRIOR TO THE START OF THE CEILING INSTALLATION.
J. CONTRACTOR SHALL EXERT CARE WHEN DRILLING INTO SLAB ABOVE AS EXISTING ELECTRICAL CONDUIT ARE
BURIED IN THE SLAB ABOVE AND LOCATIONS ARE UNKNOWN.
K. CONTACT COR PROMPTLY IF REINFORCING BAR IS DAMAGED WHILE DRILLING INTO SLAB ABOVE.
L. IN PATIENT ROOMS, CENTER LIGHT FIXTURE ABOVE PLANNED BED LOCATION. CONFORM CEILING GRID TO
ACCOMMODATE.
M. ANCHORING OF ITEMS TO THE UNDERSIDE OF BEAMS IS STRICTLY PROHIBITED, INCLUDING CONDUIT, PLUMBING, DUCTWORK, TRACK, AND OTHER SIMILAR MATERIALS/SYSTEMS.
DRAWING NOTE
1. PATIENT LIFTS ARE INCLUDED IN THE SCOPE OF WORK, COORDINATE LOCATION OF CEILING MOUNTED TRACKS WITH ALL TRADES. PATIENT ROOMS 904C AND 905C ARE TO BE PROVIDED MOBILE FLOOR LIFTS AS CEILING MOUNTED LIFTS ARE NOT POSSIBLE DUE TO EXISTING ABOVE CEILING CONDITIONS; MOBILE LIFTS ARE TO MEET WEIGHT REQUIREMENTS LISTED IN SPECIFICATION SECTION 117300 – CEILING MOUNTED PATIENT LIFT SYSTEMS
2. PNEUMATIC TUBE SYSTEM IS N.I.C. CONTRACTOR SHALL COORDINATE FOR INSTALLATION BY OTHERS DURING
CONTRACT PERIOD. REFER TO COR FOR SCHEDULING.
D C B
DD
C.1
5.1
R 8
7' - 8"
7' - 5"
R 14' - 6"
R 14' - 6"
A-504
AREA 'A'
KEY PLAN
WING 9C
95 Perry Street, Suite 300 Buffalo, NY 14203
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT: WARD 9C RENOVATIONS
3495 BAILEY AVENUE BUFFALO, NY 14215
528-18-109
528-18-109-
B
IM
/B u ff a lo
V A
W a rd
C
R e d e s ig n
C o n s tr u c ti o n /1
A R
C H
.r v t
/2 /2
:0
:2
A
M
A-404
9TH FLOOR - PARTIAL CEILING
PLAN - AREA 'A'
February 25, 2022 RAS AHE
1/4" = 1'-0"1
9TH FLOOR - AREA 'A'
1/4" = 1'-0"2
ENLARGED REFLECTED CEILING PLAN @ NURSE STATION
0' 2' 4' 8' 16'
1/4" = 1'-0"
NORTH
Revisions: Date:
BID ADDENDUM #1 2022/10/28
| Sheets |
| A-108 - 7C REFLECTED CEILING PLAN |
| A-109 - 8C REFLECTED CEILING PLAN |
| A-404 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'A' |
| A-405 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'B' |
| A-406 - 9TH FLOOR - PARTIAL CEILING PLAN - AREA 'C' |
| A-604 - EQUIPMENT SCHEDULE |
| AD-100 - 7TH FLOOR DEMOLITION CEILING PLAN |
| AD-102 - 8TH FLOOR DEMOLITION CEILING PLAN |
File details come from the government source that posted it. Updated .