Appendix A Identified Suspect ACM- Building 5.xls
XLS spreadsheet 55 KB Posted
- Solicitation number
- 36C24124B0037
About this file
This document is an appendix that identifies suspect asbestos-containing materials (ACM) in Building 5 of the VA Medical Center in Manchester, New Hampshire. The appendix provides a detailed room-by-room listing of the suspected ACM, including the location, material, estimated quantity, condition, and AHERA hazard/response assessment. The suspected ACM includes materials such as pipe insulation, flooring, and transite radiator enclosures. The appendix is referenced in Solicitation Number 36C24124B0037, which is for the demolition and construction of Buildings 2, 3, 4, 5, 13, and 14 at the VA Medical Center.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Location(s) | Material | HA | Estimated Quantity | Condition | AHERA Hazard /Response |
| Assessment | |||||
| CRAWL SPACE | |||||
| Accessible from Mechanical Room | Assumed – Debris under plastic sheeting (See Section 2.3 for additional information) | NA | NA | NA | 7/5 |
| INTERIOR | |||||
| Room C1 (Foyer) - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C1 (Foyer) - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Orange Pebble Style Sheet Flooring | 5-20 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C2 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C2 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C3 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 3 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C3 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Interior Window Frame Caulk - 3 Windows | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C4 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C4 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Residual Brown Vapor Barrier | 5-15 | NA | NA | NA | |
| Yellow Carpet Mastic | 5-14 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C5 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C5 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Residual Brown Vapor Barrier | 5-15 | NA | NA | NA | |
| Yellow Carpet Mastic | 5-14 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C6 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C6 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Residual Brown Vapor Barrier | 5-15 | NA | NA | NA | |
| Yellow Carpet Mastic | 5-14 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C7 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C7 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Residual Brown Vapor Barrier | 5-15 | NA | NA | NA | |
| Yellow Carpet Mastic | 5-14 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C8 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C8 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Residual Brown Vapor Barrier | 5-15 | NA | NA | NA | |
| Yellow Carpet Mastic | 5-14 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C9/ Room C11 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C9/ Room C11 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Residual Brown Vapor Barrier | 5-15 | NA | NA | NA | |
| Yellow Carpet Mastic | 5-14 | NA | NA | NA | |
| Interior Window Frame Caulk - 3 Windows | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C10 - ACM | White Sheet Flooring (Under other layers of flooring material) | 5-16 | 150 sq ft | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C10 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Yellow Mastic Associated with White Sheet Flooring | 5-17 | NA | NA | NA | |
| Residual Black Mastic on White Sheet Flooring | 5-18 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C12 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Mastic Associated with Fiberglass Wall Panels | NA | NA | NA | 8/5 | |
| Room C12 - Non-ACM | Ceramic Tile Grout | 5-09 | NA | NA | NA |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C13 (Foyer) - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpet | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C13 (Foyer) - Non-ACM | Ceramic Tile Grout | 5-09 | NA | NA | NA |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C14 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C14 - Non-ACM | Ceramic Tile Grout | 5-09 | NA | NA | NA |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C15 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C15 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Tan Sheet Flooring with Burlap Backing | 5-05 | NA | NA | NA | |
| Brown Vapor Barrier Associated with Tan Sheet Flooring with Burlap Backing | 5-06 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C16 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Mastic Associated with Fiberglass Wall Panels | NA | NA | NA | 8/5 | |
| Room C16 - Non-ACM | Ceramic Tile Grout | 5-09 | NA | NA | NA |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C17 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C17 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C18 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C18 - Non-ACM | Red Sheet Flooring with Burlap Backing | 5-12 | NA | NA | NA |
| Brown Vapor Barrier Associated with Red Sheet Flooring with Burlap Backing | 5-13 | NA | NA | NA | |
| Granite Style Sheet Flooring | 5-01 | NA | NA | NA | |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Interior Window Frame Caulk - 3 Windows | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C19 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C19 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Tan Sheet Flooring with Burlap Backing | 5-05 | NA | NA | NA | |
| Brown Vapor Barrier Associated with Tan Sheet Flooring with Burlap Backing | 5-06 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C20 - ACM | Green Sheet Flooring (Under other layers of flooring materials) | 5-10 | 100 sq ft | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C20 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Paper Adhesive Associated with Green Sheet Flooring | 5-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C21 - ACM | Green Sheet Flooring (Under other layers of flooring materials) | 5-10 | 135 sq ft | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C21 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Paper Adhesive Associated with Green Sheet Flooring | 5-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C22/ Room C23 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C22/ Room C23 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Tan Sheet Flooring with Burlap Backing | 5-05 | NA | NA | NA | |
| Brown Vapor Barrier Associated with Tan Sheet Flooring with Burlap Backing | 5-06 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C24 - ACM | Green Sheet Flooring (Under Carpet) | 5-10 | 225 sq ft | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C24 - Non-ACM | Yellow Carpet Mastic | 5-14 | NA | NA | NA |
| Paper Adhesive Associated with Green Sheet Flooring | 5-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C25 - ACM | Green Sheet Flooring (Under other layers of flooring materials) | 5-10 | 150 sq ft | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C25 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Paper Adhesive Associated with Green Sheet Flooring | 5-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C26 - ACM | Green Sheet Flooring (Under other layers of flooring materials) | 5-10 | 135 sq ft | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C26 - Non-ACM | Granite Style Sheet Flooring | 5-01 | NA | NA | NA |
| Yellow Mastic Associated with Granite Style Sheet Flooring | 5-02 | NA | NA | NA | |
| Paper Adhesive Associated with Green Sheet Flooring | 5-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 5-07 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C27 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Multiple layers of Flooring Materials | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Room C27 - Non-ACM | Ceramic Tile Grout | 5-09 | NA | NA | NA |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 5-07 | NA | NA | NA | |
| Room C28 (Foyer) - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpeting | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C28 (Foyer) - Non-ACM | Ceramic Tile Grout | 5-09 | NA | NA | NA |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C29 (Hallway) - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Carpeting | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C29 (Hallway) - Non-ACM | Yellow Carpet Mastic | 5-14 | NA | NA | NA |
| Tan Sheet Flooring with Burlap Backing | 5-05 | NA | NA | NA | |
| Brown Vapor Barrier Associated with Tan Sheet Flooring with Burlap Backing | 5-06 | NA | NA | NA | |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Room C30 (Hallway) - ACM | Green Sheet Flooring (Under carpet) | 5-10 | 325 sq ft | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Assumed – Flooring Paper – Under Hardwood Floor | NA | NA | NA | 7/5 | |
| Room C30 (Hallway) - Non-ACM | Yellow Carpet Mastic | 5-14 | NA | NA | NA |
| Skim Coat Plaster | 5-03 | NA | NA | NA | |
| Base Coat Plaster | 5-04 | NA | NA | NA | |
| Mechanical Room - Non-ACM | Endcap Sealant on Fiberglass Insulation | 5-21 | NA | NA | NA |
| EXTERIOR | |||||
| Roof -ACM | Roofing Materials (Assumed) | NA | NA | NA | 7/5 |
| Non-ACM | Exterior Door Frame Caulk | 5-22 | NA | NA | NA |
| Exterior Window Frame Caulk | 5-08 | NA | NA | NA |
&C&"Times New Roman,Bold"&11Appendix A Summary of Identified Suspect Asbestos-Containing Materials VA MEdical Center Building #5 Manchester, New Hampshire &L&"Times New Roman,Regular"Notes: