Appendix A Identified Suspect ACM- Building 4.xls
XLS spreadsheet 52 KB Posted
- Solicitation number
- 36C24124B0037
About this file
This document is an appendix that identifies suspected asbestos-containing materials (ACM) in Building 4 of a VA medical center in Manchester, New Hampshire. The appendix provides a detailed inventory of the suspected ACM locations, materials, estimated quantities, and condition assessments. This information is likely to be relevant for an upcoming demolition project at the medical center, as referenced in the related federal contract opportunity.
The related federal contract opportunity is a solicitation (Solicitation Number: 36C24124B0037) issued by the Department of Veterans Affairs for the demolition of Buildings 2, 3, 4, 5, 13, and 14 at the Manchester, New Hampshire VA medical center. The solicitation provides additional details on the scope of work for this construction project.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Location(s) | Material | HA | Estimated Quantity | Condition | AHERA Hazard /Response |
| Assessment | |||||
| CRAWL SPACE | |||||
| Accessible from Mechanical Room | Assumed – Debris under plastic sheeting (See Section 2.3 for additional information) | NA | NA | NA | 7/5 |
| INTERIOR | |||||
| Room W10 (Foyer) - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Flooring Materials – Under Plywood Floor | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room W10 (Foyer) - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| 12" x 12" White with Blue Fleck Floor Tile | 4-14 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" White with Blue Fleck Floor Tile | 4-15 | NA | NA | NA | |
| Yellow Covebase Mastic | 4-12 | NA | NA | NA | |
| Room W11 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Room W11 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Interior Window Frame Caulk - 3 Windows | 4-09 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Room W12 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Room W12 - Non-ACM | Sheetrock | 4-04 | NA | NA | NA |
| Joint Compound | 4-05 | NA | NA | NA | |
| Interior Window Frame Caulk - 5 Windows | 4-09 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Yellow Covebase Mastic | 4-12 | NA | NA | NA | |
| Room W13 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Room W13 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Room W14 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room W14 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Room W15 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room W15 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| 12" x 12" White with Blue Fleck Floor Tile | 4-14 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" White with Blue Fleck Floor Tile | 4-15 | NA | NA | NA | |
| Yellow Covebase Mastic | 4-12 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| Room W16 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W16 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| Ceramic Tile Grout | 4-08 | NA | NA | NA | |
| Room W16A - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W16A - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| 12" x 12" White with Blue Fleck Floor Tile | 4-14 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" White with Blue Fleck Floor Tile | 4-15 | NA | NA | NA | |
| Room W20 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W20 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Textured Ceiling Application | 4-07 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Room W21 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W21 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Room W22 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room W22 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Textured Ceiling Application | 4-07 | NA | NA | NA | |
| Ceramic Tile Grout | 4-08 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| Room W23 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W23 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Room W23A - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W23A - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| Ceramic Tile Grout | 4-08 | NA | NA | NA | |
| Room W24 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W24 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Room W25 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room W25 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| 12" x 12" White with Blue Fleck Floor Tile | 4-14 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" White with Blue Fleck Floor Tile | 4-15 | NA | NA | NA | |
| Yellow Covebase Mastic | 4-12 | NA | NA | NA | |
| White Sink Coating | 4-13 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| Room W26 | No Access | NA | |||
| Room W28 (Stairway) - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room W28 (Stairway) - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Textured Ceiling Application | 4-07 | NA | NA | NA | |
| Stair Tread Mastic | 4-16 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| Room E10 (Foyer) - ACM | Pipe Insulation (Aircell) – Enclosed in Ceiling | 4-19 | 10 ln ft | Fair | 1/2 |
| Pipe Fitting Insulation Associated with Aircell Pipe Insulation | 4-20 | 4 ea | Fair | 1/2 | |
| Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room E10 (Foyer) - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| 12" x 12" Tan Floor Tile | 4-17 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" Tan Floor Tile | 4-18 | NA | NA | NA | |
| 12" x 12" Blue Floor Tile | 4-22 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" Blue Floor Tile | 4-23 | NA | NA | NA | |
| Vapor Barrier (Flooring Paper) Under Hardwood Flooring | 4-21 | NA | NA | NA | |
| Room E11 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Room E11 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 3 Windows | 4-09 | NA | NA | NA | |
| Room E12 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Room E12 - Non-ACM | Sheetrock | 4-04 | NA | NA | NA |
| Joint Compound | 4-05 | NA | NA | NA | |
| Interior Window Frame Caulk - 5 Windows | 4-09 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Yellow Covebase Mastic | 4-12 | NA | NA | NA | |
| Room E13 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Room E13 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Room E14 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room E14 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Room E15 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room E15 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| 12" x 12" Tan Floor Tile | 4-17 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" Tan Floor Tile | 4-18 | NA | NA | NA | |
| Ceramic Tile Grout | 4-08 | NA | NA | NA | |
| Room E16 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room E16 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| 12" x 12" Tan Floor Tile | 4-17 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" Tan Floor Tile | 4-18 | NA | NA | NA | |
| Room E17 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room E17 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| 12" x 12" Tan Floor Tile | 4-17 | NA | NA | NA | |
| Yellow Mastic Associated with 12" x 12" Tan Floor Tile | 4-18 | NA | NA | NA | |
| Room E20 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room E20 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Textured Ceiling Application | 4-07 | NA | NA | NA | |
| Room E22 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room E22 - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Textured Ceiling Application | 4-07 | NA | NA | NA | |
| Ceramic Tile Grout | 4-08 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| Room E23 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Room E23 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock | 4-04 | NA | NA | NA | |
| Joint Compound | 4-05 | NA | NA | NA | |
| Ceramic Tile Grout | 4-08 | NA | NA | NA | |
| Room E24 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Room E24 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Room E25 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Room E25 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Room E26 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room E26 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| Room E27 - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 1 Radiator Enclosure | NA | NA | NA | 7/5 | |
| Room E27 - Non-ACM | 2' x 4' Ceiling Tile | 4-06 | NA | NA | NA |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Skim Coat Plaster | 4-02 | NA | NA | NA | |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Yellow Carpet Mastic | 4-11 | NA | NA | NA | |
| Interior Window Frame Caulk - 2 Windows | 4-09 | NA | NA | NA | |
| Room E28 (Stairway) - ACM | Assumed – Pipe Insulation – Enclosed in Wall Chase | NA | NA | NA | 7/5 |
| Assumed – Pipe Insulation – Enclosed in Ceiling | NA | NA | NA | 7/5 | |
| Assumed – Transite – 2 Radiator Enclosures | NA | NA | NA | 7/5 | |
| Room E28 (Stairway) - Non-ACM | Skim Coat Plaster | 4-02 | NA | NA | NA |
| Base Coat Plaster | 4-03 | NA | NA | NA | |
| Sheetrock Associated with Plaster Ceilings and Walls | 4-01 | NA | NA | NA | |
| Textured Ceiling Application | 4-07 | NA | NA | NA | |
| Stair Tread Mastic | 4-16 | NA | NA | NA | |
| Interior Window Frame Caulk - 1 Window | 4-09 | NA | NA | NA | |
| EXTERIOR | |||||
| Roof - ACM | Roofing Materials (Assumed) | NA | NA | NA | 7/5 |
| Doors - ACM | Exterior Door Frame Caulk | 4-24 | 6 ea | Good | 7/5 |
| Exterior - Non-ACM | Exterior Window Frame Caulk - 35 Windows | 4-10 | NA | NA | NA |
&C&"Times New Roman,Bold"&11Appendix A Summary of Identified Suspect Asbestos-Containing Materials VA Medical Center Building #4 Manchester, New Hampshire &L&"Times New Roman,Regular"Notes:
1) Please refer to the report for additional inforamtion regarding the scope of work and limitations of this inspection.&RA-&P
Sheet2
Sheet3