Attachment A - walk-in inventory2.xlsx
XLSX spreadsheet 65 KB Posted
- Solicitation number
- 33330226RF0010043
- Issued by
-
Smithsonian Institution
About this file
This is an inventory spreadsheet documenting the condition and specifications of approximately 70 Environmentally Controlled Walk-In (ECW) units across Smithsonian Institution facilities located in Washington DC, Suitland MD, Front Royal VA, Edgewater MD, Chantilly VA, and Landover MD. The spreadsheet captures detailed technical data for each unit including interior and exterior dimensions, door specifications, operational status, environmental control settings (temperature, relative humidity, radiation levels), refrigeration system components (compressor, condenser, evaporator manufacturers and serial numbers), electrical configurations, safety features (fire suppression systems, alarms, emergency generators), and current condition ratings (Green for good condition, Yellow for minor issues requiring attention, Red for significant problems). The inventory also documents specific deficiencies and recommended repairs for each unit, such as air filter replacements, insulation repairs, drain line clearing, refrigerant charge adjustments, light bulb replacements, and in some cases complete system rebuilds or decontamination procedures.
The data reveals significant variation in equipment age, condition, and maintenance requirements across the SI portfolio. Units manufactured between 1987 and 2024 are documented, with many older units (pre-2010) showing substantial wear requiring major repairs or replacement. Common issues identified include clogged drain lines, deteriorated door gaskets, compromised insulation, mold contamination, failing compressors, and improper refrigerant charges. Multiple units rated Red require immediate attention, including complete refrigeration system rebuilds, box replacement, and decontamination. The inventory serves as the baseline assessment supporting the Smithsonian's IDIQ solicitation 33330226RF0010043 for planned maintenance and inspection services, which requires contractor-provided semi-annual PM&I services, emergency response capabilities, certified technicians, and comprehensive reporting on all ECW units through a potential ten-year performance period.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 2.pdf | ||
| RFI Responses 22 thru 26.pdf | ||
| Sign In Sheet for Site Visit.pdf | ||
| RFI Responses 1 thru 21.pdf | ||
| 33330226RF0010043 Final with (SF33).pdf | ||
| Amendment 1.pdf | ||
| 33330226RF0010043 Final.pdf | ||
| Attachment B - Walk-ins First Site Visit Survey Attributes.xlsx | XLSX spreadsheet | |
| Attachment C - first site visit.xlsx | XLSX spreadsheet | |
| Walk-in PMI Contract SOW .docx | DOCX document | |
| Bid Sheet for walk-in Solication.xlsx | XLSX spreadsheet | |
| Attachment A - walk-in inventory.xlsx | XLSX spreadsheet | |
| Attachment D - Asset Management (AMD) Requirements.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Date Completed | OFEO Tag Number | Interior Dimensions WxDxH | Exterior Dimensions WXDXH | Door Dimensions WXH | Final Rating of existing condition: Green, Yellow, or Red. | Site: NMNH, NMAH, NMAAHC, NASM, NASM-UHC, NMAI, ACM, HMSG, SERC, SCBI, NMAA (FREER), DWRC, NZP, Capital Gallery Administrative HQ, Quad, NPM, Pennsy, or other | Building | Street address of site: | Room # or location (SPACE ID) | Condenser location if other (SPACE ID) | Exterior walk-in? | Is the walk-in operational? | Are OEM manual and/or certification records available? | Are inspection and/or service reports available? | Any special safety or care instructions with the stored product or walk-in? | Is unit being used | Is the unit operating at requested parameters (at time of inspection) | Any and all desired environmental control condition(s) set point: Temperature (C/F) | Relative Humidity | Radiation level | Lighting | Other | Oil Level | Sight Glass (Refrigerant charge) | What year was the walk-in manufactured? | Power supply location (panel/breakers) | Condition of electrical wiring and connections | Amperage ratings | Is the Walk-in on the emergency generator? | Is the Walk-in on a Building Automatic System (BAS)? | If yes, Is the BAS local or on a central system? | Does the walk-in have a local alarm? | Does the Walk-in have a backup refrigeration system or a Redundant system? | Safety features of the walk-in: Fire suppression system in the walk-in | If yes, what type (connected to the building system, local suppression tanks, or other)? | Other safety feature(s) of the walk-in (e.g., trapped person alarm (visual or audible), door sensors, phone in walk-in, etc.) | Structural manufacturer (If not part of the building) | Controller manufacturer, | Model # | Serial # | Compressor Info | Condition and /or other pertinent information: | Condenser manufacturer | Model #2 | Serial #3 | Condenser coils | Condition and /or other pertinent information:4 | Evaporator manufacturer | |
| 7/2/24 | FM04347 | 30X83X12 | N/A | 4FX7F | Yellow | NASM | UHC | 14390 Air and Space Museum ParkwayChantilly, VA 20151 | 218.39 | Outside by loading dock 5&6 | NO | Yes | Facilities | Facilities | Need to be badged in | Yes | Yes | 4C | 30% | N/A | Good | N/A | Good | Good | N/A | S4216P3 breakers 1-11 | Good | 150A | Yes | Yes | Local | Yes | No | Yes | Sprinkler system | HFC-125extinguishing system | Imperial manufacturing | Environmental specialties | ES 84-30CR | 1390-218.39 | Copeland MDL: ZF40K4E-TWD-951 SN: 11E961184 | Good | HeatCraft | LZT045M6D | T10E08223 | Aircooled | Good | N/A | |
| 6/2/24 | FM04323 | 30ft x 83ft x 12 | Build into building | 4'x7' | Yellow | NASM | UHC Bldg | 14390 Air and Space Museum ParkwayChantilly, VA 20151 | 218.37 | Outside By Loading Dock 5&6 | N/A | Yes | Facilities | Yes | You need to be badged in for entry. | Yes | Yes | 15C 30% | 30% | N/A | Good | Good | Good | Good | N/A | S4216P3 breakers 2-6 | Good | 150A | Yes | Yes | Local | Yes | No | Yes | Sprinkler | HFC-125 extinguishing system release | Imperial manufacturing | Environmental specialties | ES 8-31R | 1390-218.37 | Copeland MDL: 8T5K4E-TFD-230 S/N: 10D0627CD | Good | Heatcraft | LZT020M6D | T10E08219 | Air cooled | Good | Heatcraft | |
| 6/2/24 | FM04348 | 30'X11'X12' | N/A | 4'X7' | Green | NASM | UHC | 14390 Air and Space Museum ParkwayChantilly, VA 20151 | 218.4 | Outside by loading dock 5&6 | N/A | Yes | Facilities | Onsite Facilities | You need to be badged in | Yes | Yes | -4c | Good | N/A | Good | N/A | Good | Good | N/A | Panel: S4216P3, Breaker: 8-12 | Good | 150 | Yes | Yes | Local | Yes | No | Yes | Sprinkler System | HFC-125 Extinguisher System Release | Imperial manufacturing | Environmental specialties | ES 11-30FZ | 1390-218.40 | Copeland Mdl# ZS30K4E-TDF-250, SN# 10D1588AD | N/A | HeatCraft | LZT045M6D | T10E08223 | Air Cooled | N/A | N/A | |
| 7/3/24 | FM04324 | 16'X17'X12' | BUILD INTO THE WALL | 8'X8' | Green | NASM-UHC | NASM-UHC | 14391 Air and Space Museum ParkwayChantilly, VA 20151 | 217.01 | Mechanical Space 320.06 | N/A | Yes | Possible Facilities | Possible Facilities | Need to be badged into box | Yes | Yes | 16.0C | 40.00% | N/A | Good | N/A | Good | Good | Unkown | S4216P2 BREAKERS: 14,16,18 | Good | 150A | Yes | Yes | Local | Yes | No | YES | DRY CLEAR AGENT SUPPRESSION, HFC-125 EXTINGUISHER | Need to be badged in | N/A | Environmental specialties | ES 17-16CR | 1390-217.01 | Copeland MDL: zs19kae-Tfd-118 SN: 18D68F08L | N/A | Heatcraft | LZT0700M6D | T18E16205 | Air Cooled | N/A | Larkin | |
| 7/3/24 | FM04325 | 63'X30'12' | N/A | 8'X8' | Yellow | NASM-UHC | UHC | 14392 Air and Space Museum ParkwayChantilly, VA 20151 | 217.02 | 320.06 | N/A | Yes | Facilities | Facilities | Need an escort | Yes | Yes | 12.8C 45.0% | 45% | N/A | Good | N/A | Good | Full | N/A | PANEL- S4216P2 BREAKERS-13,15,17 | Good | 150A | Yes | Yes | Local | Yes | No | Yes | HFC-125 extinguishing system | N/A | N/A | Environmental specialties | ES31 - 55CR | 1390-217.02 | COPELAND MDL: ZS45K4E-TFD-250, SN: 18E4544AD | N/A | Heatcraft | LZT060M60 | T18E17^87 | Aircooled | N/A | N/A | |
| 7/3/24 | FM04326 | 30'X80'X12' | N/A | 3'X8' | Yellow | NASM-UHC | UHC | 14393 Air and Space Museum ParkwayChantilly, VA 20151 | 217.05 | Mechanical Room 320.06 | No | Yes | Facilities | Facilities | Need an escort | Yes | Yes | 18.0c | 35.00% | N/A | Good | N/A | Good | Good | N/A | PANEL-S4216P2 BREAKERS:1-11 | Good | 150A | Yes | Yes | Local | Yes | No | YES | DRY CLEAR AGENT SUPPRESSION. HFC-125 extinguishing system | Need to be badged in | N/A | Environmental specialties | ES80-30CR | 1390-217.05 | COPELAND MDL: ZB58K5E-TFD-260, SN: 18DC4206D | N/A | Heatcraft | SZT025M60SP | T18E17682 | Aircooled | N/A | N/A | |
| 7/9/24 | FM04327 | 85x63x12 | N/A | 8'x8' | Green | NASM-UHC | UHC | 14394 Air and Space Museum ParkwayChantilly, VA 20151 | 220.08 | Mechanical Room# 320.06 | N/A | Yes | Facilities | Facilities | N/A | Yes | Yes | 50F/45% | Good | N/A | Good | N/A | Good | Good | N/A | S7220L1/breaker 1,3,5 | Good | 150A | Yes | Yes | Local | Yes | Yes | Sprinkler system | Local | 2 Phones inside of box | R-PLUS Cold Storage | Bahnson | ES 64-87CR | 1836-220.08 | MDL:3DA3R10ME-TFD-C40 S/N:18E00348R, 18D00199R | Controller located in Mechanical Room# 220.06 | Keeprite | KESA080H8-HT4C-X2465 | 182206575, 182206574 | Aircooled | N/A | Trane | |
| 7/9/24 | FM04329 | N/A | 48'Wx18'H | 6'8' | Yellow | NASM-UHC | UHC | 14395 Air and Space Museum ParkwayChantilly, VA 20151 | 214.31 | On roof | NO | Yes | Facilities | Facilities | Yes, radiation is stored inside walk-in and we are not allowed in without special clearance/PPE | Yes | Yes | 72F | 35% | High | N/A | N/A | N/A | System A-Good, System B- N/A | Unkown | ECR-C9 4214D1- Breakers 37,39,41 | Good | 150 | Yes | Yes | Local | Yes | Yes | Yes | Water sprinkler system | Unknown | Norlake | Siemens | N/A | N/A | System A compressor- ALLIANCE MDL- SXA051BABPA, SN: 17BJ9346N. System 2 compressor MDL: SXA051BABPA, SN: 17DJ9310N | Air cooled | Odyssey | TWA120E40RAA | 17274PH5YA | Aircooled | Both systems use one condenser coil | Trane | |
| 7/9/24 | FM04328 | 84'Wx63'Dx12'H | N/A | 8'x8' | Green | NASM-UHC | UHC | 14396 Air and Space Museum ParkwayChantilly, VA 20151 | 320.09 | In mechanical room# 320.06 | No | Yes | Facilities | Facilities | Need to be badged for entry | Yes | Yes | 37F/30% | Good | N/A | Good | N/A | Good | Good | 2018 | S7320L1, Breakers: 1,3,5 | Good | 150A | Yes | Yes | Local | Yes | Yes | Yes | Water sprinkler system | Unit has two interior phones | Imperial Brown | Bahnson Environmental Specialties | ES64-87CR | 1836-320.09 | Model: 3DF3R15ME-TFD-C40, SN# 18D01393R, 18D01392R | No | Keeprite | MDL# KESA120H8-HT4C-X2464 | SN# 182206572, 182206573 | Air Cooled | N/A | Trane | |
| 10/25/24 | FM04633 | 10'8"x7'7"x11' | 11'8"x8'9"x11'9" | 4'8"x8'1" | Green | NMAI | NMAI | 300 Maryland Ave SW | |||||||||||||||||||||||||||||||||||||||||
| Washington DC 20024 | Collections Room Basement 0026 | Loading Dock | N/A | Yes | Yes | Yes | N/A | Yes | Yes | -38F | N/A | N/A | Good | N/A | Good | Good | Unknown | Unknown | Unknown | Unknown | Yes | N/A | N/A | N/A | Yes | Yes | Water Sprinkler System | N/A | Thermalrite By Everidge | Watlow | SD31 | N/A | Bitzer Compressors System A & B MDL: S4T-5.2Y, System A SN: 25H2007557, System B SN: 664201639 | N/A | Century Refrigeration | WCBD10XLT7 | 09-03-064931-001-001 | Water Cooled | Condenser Rack is supened in the air | Century Refrigeration | Both systems MDL: A1517-206E | System A SN: 12-16-126183-001-001, System B SN: 09-03-064931-002-001 | Good | N/A | Good | N/A | R507 | Good | Good |
| 10/8/23 | FM04390 | 8'x12'10x8' | 7'x13'x8' | 5'1"x7'5" | Green | Cultural Resources Center | CRC Bldg | 4220 Silver Hill RdSuitland, MD 20746 | LL2131 Isolation Room | On the Roof | N/A | Yes | Yes | Yes | Need key to open door | Yes | Yes | -27F | N/A | N/A | Good | N/A | Good | Good | Approx. 2001 | N/A | Good | N/A | Yes | Yes | Local | Yes | N/A | Yes | Water Sprinkler System | Panic Alarm Button | ThermalRite | Johnson Controls | Electrical Thermostat | N/A | Bitzer MDL: S4T-5.2Y-2NU | 258698112 | HeatCraft | BCU1005ABEX6C2 | A15B00082 | Air Cooled | N/A | BOHN |
One stick of 1-3/8x3/4
| 10/8/24 | FM04383 | 4'2"x7'x7'8" | 5'x7'7"x8'5" | 3'x7' | Green | Cultural Resources Center | CRC Bldg | 4221 Silver Hill RdSuitland, MD 20746 | Trash/Recycling LL2117 | On top of box | N/A | Yes | Unknown | Unknown | N/A | Yes | Yes | ? | N/A | N/A | Good | N/A | N/A | Good | N/A | N/A | N/A | N/A | Yes | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Bally | Johnson Controls | Penn Mechanical Thermostat | N/A | Copeland Compressor MDL: KANB-007E-CAV-800, SN: ET 16C62767R | N/A | Russell | RLS075M44-D | E15H00729270001001 | Air Cooled | N/A | N/A | N/A |
| 10/9/24 | FM04397 | 21.5'x11'x8' | N/A | 3'X7' | Green | Cultural Resources Center | CRC Bldg | 4222 Silver Hill RdSuitland, MD 20746 | LL2098 | On the Roof | N/A | Yes | Yes | Yes | Yes | Yes | Yes | 1.5c | 37% | N/A | Good | Good | N/A | Good | Approx.2001 | Unknown | Unknown | Unknown | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinkler System | Audio, Visual Alarms, & Panic Alarm Button | Bally | SCE Controller | IEC 60529 | 3820372 | Copeland Scroll System A&B MDL: ZS15KAE-TF5-118, System A SN: 19H82C3IL, System B SN: 19H82C28L | N/A | HeatCraft | System A&B MDL: BZT020M6C | System A SN: T19K19956, System B SN: T19K19955 | Air Cooled | N/A | BOHN | System A&B MDL: ADT156AEK |
Hot Gas Insulation: 1/2x1/2 (4sticks) Suction line: 7/8x1/2 (4sticks Needs one more “Durablock Pipe Supprt” With three cushion clamps (3/8,1/2,7/8) one of each. Also System B Hot Gas: 1/2x1/2 (2sticks) Suction line: 7/8x1/2 (2 sticks)
| 7/17/24 | FM04268 | 18'x50'x11' | N/A | 3'x7' | Yellow | American History | American History | 1400 Constitution Ave NWWashington DC 20013 | BB018 | Mechanical Space | No | Yes | Yes | Yes | N/A | Yes | No | 45F | 45RH | N/A | Poor | N/A | Good | Good | 1998 | BB017D | Good | 30A | Yes | Yes | Local | Yes | No | Yes | Water Sprinkler System | Need to be badged in by end user; security key needed from security office | Bally Case & Cooler | White-Rodger's Mechanical Thermostat | N/A | N/A | Copeland MDL# 2DC3-050E-TFD-800, SN# 01F69381R | Dates back from 2001 | Heatcraft | TRH050H24N | T96M01144 | Air Cooled | Noticed condenser coil slightly damaged | Sine air handler | SSH-9 |
| 10/1/24 | FM04381 | 24'8"x58'8"x9'2" | 24'10"x66'x9'6" | 7'5"x8'2" | Green | Paul E. Garber Facility | Bldg 24 | 3904 Old Silver Hill RdSuitland, MD 20746-3190 | NASM Space Suit Storage 1 | Outside of building | N/A | Yes | Unknown | Unknown | Need to be badged into Walk-in | Yes | Yes | Unknown-Siemens Controls | Unknown-Siemens Controls | N/A | Good | N/A | N/A | N/A | Approx. 2006 | EP-01-07 | Good | 60A | Unknown | Yes | Local | Yes | N/A | Yes | Water Sprinkler System | Audio and Visuals Alarms | Bally | Siemens Controlled | Simatic Panel | N/A | Data Plate is not legible | Small Condenser | Possible York unit but date plate is gone. | N/A | N/A | Air Cooled | N/A | Munthers | HCD-600-SMFBCS |
| 10/1/24 | FM04389 | 24'6"x62'2"x12'1" | 25'4"x63'x12'5" | 4'2"x8'1" | Green | Paul E. Garber Facility | Bldg. 24 | 3905 Old Silver Hill RdSuitland, MD 20746-3190 | NASM | Outside next to building | N/A | Yes | Unknown | Unknown | Need to be badged in | Yes | Yes | Unknown-Siemens Controlled | N/A | N/A | Good | N/A | Good | Good | Aprox. 2001 | Unknown | Unknown | Unknown | Unknown | Yes | Local | Yes | N/A | Yes | Water Sprinkler System | Audio & Visual Alarms | Bally | Siemens Controlled | N/A | N/A | Copeland | Unable to read Comp data plate. | N/A | N/A | N/A | Air Cooled | Unable to read Comp data plate. | Unknown | N/A |
| 10/1/24 | FM04388 | 24'6"x62'2"x12'1" | 25'4"x63'x12'5" | Door 1 - 4'2"x8'1" Door 2 - 3'2"x6'7" | Green | Paul E. Garber Facility | Bldg. 24 | 3906 Old Silver Hill RdSuitland, MD 20746-3190 | NASM Small Objects Storage | N/A | N/A | Yes | Unknown | Unknown | Need to be badged in | Yes | Unknown | Unknown-Siemens Controlled | N/A | N/A | Good | N/A | N/A | N/A | Approx. 2001 | Unknown | Unknown | Unknown | Unknown | Yes | Local | Yes | N/A | Yes | Water Sprinkler System | Audio and Visual Alarms | Bally | Siemens Controlled | N/A | N/A | Compressor MDL: SPA036B4BPA / SN:08BA7261N | This unit has a reversing valve. | N/A | N/A | N/A | Air Cooled | This unit is a package unit. | N/A | N/A |
| 10/1/24 | FM04387 | 24'6"x37'10"x12'1" | 25'4"x38'6"x12'5" | Door 1 - 3'2"x6'7" Door 2 - 4'2"x8'1" | Yellow | Paul E. Garber Facility | Bldg. 24 | 3907 Old Silver Hill RdSuitland, MD 20746-3190 | NASM Box 6 Art Storage | Outside next to building | N/A | Yes | Unknown | Unknown | Need to be badged in | Yes | Unknown | Unknown-Siemens Controlled | Unknown-Siemens Controlled | N/A | Good | N/A | N/A | N/A | Approx. 2001 | Unknown | Unknown | Unknown | Unknown | Yes | Local | Yes | N/A | Yes | Water Sprinkler System | Audio and Visual Alarms | Bally | Siemens Controlled | N/A | N/A | Compressor MDL: ZR18K5E-PFV-130 / SN:16C3D684M | N/A | Emerson | PFH020A-PL7 | Y16FG10072 | Air Cooled | N/A | Emerson | DME020E-PH7 |
| 10/1/24 | FM04385 | 24'4"x78'11"x11'3" | N/A | 6'4"x7'2" | Green | Paul E. Garber Facility | Bldg. 24 | 3908 Old Silver Hill RdSuitland, MD 20746-3190 | NASM Flight Material Storage | Outside next to building | N/A | Yes | Unknown | Unknown | Need to be badged in | Yes | Unknown | Unknown-Siemens Controlled | Unknown-Siemens Controlled | N/A | Good | N/A | N/A | N/A | Approx. 2001 | Unknown | Unknown | Unknown | Unknown | Yes | Local | Yes | Yes, their are two independent refrigeration circuits that use the same condenser and air handler. | Yes | Water Sprinkler System | Audio and Visual Alarms | Part of the Building | Siemens Controlled | N/A | N/A | Circuit A & B Compressor MDL: GP813-NN3-GA, Circuit A SN: Z015RU1N, Circuit B SN: Z015RX8N | N/A | America Standard Inc. | TTA150B300CA | Z071293AH | Air Cooled | Condenser Coil has two refrigeration circuits | America Standard Inc. | TWE180B300CA |
| 10/31/24 | FM04653 | N/A | N/A | N/A | Yellow | ACM | Anacostia Community Museum | 1901 Fort Place SE, MRC 777Washington DC 20020 | 122 | On the roof | N/A | N/A | Unknown | Unknown | Need to be badged | N/A | No | 60C | 50% | N/A | Good | N/A | N/A | N/A | 2016 | Unknown | Unknown | Unknown | Yes | N/A | N/A | N/A | N/A | Yes | Water Sprinkler System | Man Down Button | KPS Global | Allen Bradley | 2711C-T6T | 44421476 | Copeland | 2DA3R89KE-TFC-C40 | HeatCraft | LDT0751M6CS | A16C00202 | Air Cooled | N/A | Unknown | Unknown |
| 10/31/24 | FM04654 | N/A | N/A | N/A | Green | ACM | Anacostia Community Museum | 1901 Fort Place SE, MRC 777Washington DC 20020 | Warm Room RM#123? | On the roof | N/A | Yes | Unknown | Unknown | Need to be badged in | No | Yes | 70F | 50% | N/A | Good | N/A | Poor | N/A | 2016 | Pane: PCR RM 124 / Breakers 7, 9, 14, 16, 18, 20, 22, 24 | Good | 30A | Unknown | Yes | Local | Yes | N/A | Yes | Water | N/A | KPS Global | Harris Environmental Systems | Job#152368 No MDL | N/A | MDL: ERFA-031E-TAC-220 / SN: ET16C00460R | N/A | Larkin | LST030M6CS | A16C00204 | Air Cooled | Unknown | Unknown | N/A |
| 7/17/24 | FM04270 | 9'X11'X8' | 11'7"xx8' | 5'x6.5' | Yellow | HMSG | HMSG | 7th St and Independence Ave SW Washington DC 20560 | GO7 B | On top of walk-in | NO | Yes | Unknown | Facilities | Need to be badged in by end user | Yes | Yes | 60F | 40 RH | N/A | Good | N/A | N/A | Good | 2004 | UPGC,BREAKER 2,6,17,21 | Good | 20A | YES | YES | LOCAL | YES | NA | YES | WATER SPRINKLER SYSTEM | N/A | Bally Refrigeration | PARTLOW MRC 7000 | NA | NA | COPELAND, MDL# RST70C1E/SN#19H09131E | N/A | RUSSELL | REH100H22-D | W04J26390101001 | AIR COOLED | CONDENSER COIL HAS A 7"GAP BETWEEN COIL AND DRYWALL | Russel | AA58-275B-A |
| 7/17/24 | FM04266 | 8'x19'x8' | N/A | 5'x7' | Yellow | HMSG | HMSG | 8th St and Independence Ave SW Washington DC 20560 | Walk-in is accessed through +60F walk-in | On top of walk-in | No | Yes | Yes | Yes | Need to be badged in by end user | No | No | 40F | 40RH | N/A | Good | N/A | N/A | Good | 2004 | Panel- UPGC, Breakers- 1,7,4,18,20,22 | Good | 20A | Yes | Yes | Local | Yes | No | Yes | Water sprinkler system | N/A | Bally Refrigeration | PARTLOW MRC7000 | N/A | N/A | COPELAND MDL# CR32K6E-PFV-875, SN# 21HAT312M | N/A | RUSSELL | REH251H22-D | W04J26390104001 | Air Cooled | Condenser coil has some damage, refrigeration seems fine at the moment | RUSSELL | AA58-275B-A |
| 10/23/24 | FM05913 | 16'5"X13'4"X9'6" | N/A | 3'3"X6'10" | Green | QUAD | Museum Of African Art | 1100 Independence Ave SWWashington DC 20560 | Sublevel 2 - 2139 Inside 2140 Eliot Elisofon Archives | In Large closet of the Library to the right of 2140 Eliot Elisofon Archives | No | Yes | Yes/Local - Also Welch & Rushe | Yes/Local - Also Welch & Rushe | Yes Badge In | Yes | Yes | 45F | 25% | N/A | Good | N/A | Good | Good | Unknown | Unknown | Good | 30A | No | No | N/A | Yes | Yes | Yes | Water sprinkler | Audible alarm | Unknown | Penn Mechanical | N/A | N/A | Copeland Compressors System A & B MDL: KAGA - 0150TAC200, System A SN: CCC0610810, System B SN: CCK0514611 | Good | Trenton Refrigeration | A & B MDL: TESA015H2-HT3A-B | A SN: 060200733, System B SN: 060102316 | Air Cooled | Good | Trenton Refrigeration | A & B MDL: TLP123A |
| 10/24/24 | FM04379 | 11'2"X16'8"X8'10" | N/A | 3'3"X6'10" | Red | QUAD | Museum Of Asian Art | 1101 Independence Ave SWWashington DC 20560 | Sublevel 2 - 2062 Archives | N/A (Was on Top of Box) | No | No | Yes/Local Facilities | Yes/Local Facilities | Yes Badge In | Yes | No | N/A | N/A | N/A | Good | N/A | N/A | N/A | Unknown | Room 2062A - Panel LDP2A / Breakers 19,21, & 23 | Good | 20A | N/A | No | No | No | No | Yes | Water sprinkler | Audible alarm | Unknown | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 10/31/24 | FM04650 | 9'2"x12'6"x7'1" | 9'9"x13'6"x7'5" | Red | QUAD | Quad Loading Dock Near Ripley Center | 1102 Independence Ave SWWashington DC 20560 | Loading Dock- Compost Room | On top of Walk-in | N/A | No | Unknown | Unknown | N/A | Yes | No | 40F | N/A | N/A | Good | N/A | N/A | N/A | Unknown | Not able to locate power supply | N/A | N/A | Unknown | No | N/A | N/A | No | Yes | Water Sprinkler System | Safe gaurd door release safety | Victory | Johnson Controls | Penn Mechanical Thermostat | N/A | Tecumseh Compressor MDL# AJA4512YXD SN# 04C041521897429X | 208V | Tecumseh | AJA45122YXDXC | 18D2115292625 | AJA45122YXDXC | Air Cooled | Heatcraft | SM090AE | |
| 10/7/24 | N/A | 9'10"x8'11"x7'8" | N/A | 3'9"x6'3" | Green | Capital Gallery Administrative HQ | Capital Gallery | 600 Maryland Ave SWSuite 760E, MRC 500Washington DC 20024 | 3210 Staging | Mechanical Room | No | Yes | Yes/Local | Yes/Local | No | Yes | Yes | -18F | N/A | N/A | Good | N/A | Good | Good | 2006 | Panel L3B2 / 24,26,28 | Good | 50A | No | Yes | Local | Yes | No | Yes | Water Sprinkler | Trapped person, Slip, Visual, & Audible Alarms | N/A | Climate Technologies | N/A | N/A | M/N: LAHA-032E-TAC-220 S/N: ET06D04139 | N/A | Larkin | SWN0310L6C | T06D05014 | Water Cooled | N/A | Heatcraft | LCA6160AHB |
| 10/7/24 | N/A | N/A | N/A | N/A | Green | Capital Gallery Administrative HQ | Capital Gallery | 600 Maryland Ave SWSuite 760E, MRC 500Washington DC 20024 | 3240 Archives Collections | 3220 Mechanical Room | No | N/A | Yes/Local | Yes/Local | Yes, you need to be badged in. | Yes | Yes | 60F - 62F | 50% | N/A | Good | N/A | Good | Good | N/A | 3220 Mechanical Room | Good | N/A | N/A | Yes | Local | Yes | No | Yes | Water Sprinkler | Trapped person, Slip, Visual, & Audible Alarms | N/A | N/A | N/A | N/A | N/A | N/A | Trane | MCCB017UA0A0UA | K06A12388 | Water Cooled | N/A | N/A | N/A |
| 10/17/24 | FM04367 | 34'2"X32'9"X7'11" | N/A | 3'2"X6'7" | Green | Pennsy | Main Building | 3400 Pennsy Dr Hyattsville, MD 20785-1607 | 01FFF60 (You have to go through 01EEE58 & 01EEE60 To Access) | Roof | No | Yes | Yes/Local Facilities | Yes/Local Facilities | Yes Badge In | Yes | Yes | 11C | 30% | N/A | Good | N/A | Good | Good | 2015 | 01FFF55 CC#2 | Good | 30A | Unknown | Yes | Local | Yes | No | Yes | Water sprinkler | Visual, audible, and trapped person alarm | Imperial Brown | Environmental Growth Chambers | EGC TC2 | N/A | MDL#:ZB30CE-TFD-250 / SN#: 15B5466AD | Good | Copeland | FJAM-A40Z-TFD-015 | 15BL0408U | Air Cooled | Good | Heatcraft (Total of 4 Evaporators) | LSC140BEK |
| 10/18/24 | FM04378 | 37'3"X37'3"X7'11" | N/A | 3'2"X6'7" | Green | Pennsy | Main Building | 3401 Pennsy Dr Hyattsville, MD 20785-1607 | 01FFF58 (You have to go through Cooler To Access) | Roof | No | Yes | Yes/Local Facilities | Yes/Local Facilities | Yes Badge In | Yes | Yes | 26F | 30% | N/A | Good | N/A | Good | Good | 2015 | 01FFF55 CC#1 | Good | 30A | Unknown | Yes | Local | Yes | No | Yes | Water sprinkler | Visual, audible, and trapped person alarm | Imperial Brown | Environmental Growth Chambers | EGC TC2 | N/A | MDL#:ZB45KCE-TFD-965 / SN#: 20E4041AD | Good | Copeland | FJAM-A60Z-TFD-015 | 15CL0073U | Air Cooled | Good | Heatcraft (Total Of 4 Evaporators) | LSF160BEK |
| 7/16/24 | FM04273 | 10'x10'x8 | 11'x11'x9 | 5'X6' | Red | NMNH | NMNH | 10th and Constitution Ave NW Washington DC 20560 | EG19 | Machine Room-Ground Floor | No | No | Possibly Facilities | Possibly Facilities | No | No | No | -5F | N/A | N/A | N/A | N/A | Poor | N/A | 2002 | PANEL: EWGNL7, BREAKERS: 19,21 | Good | 20A | Yes | No | N/A | No | No | Yes | Water sprinkler system | No | Bally Refrigeration Boxes | Ranco, Mechanical T-Stat | N/A | N/A | Copeland, MDL: 2DF3F16KETFC200, SN# CCB0810528 | N/A | BALLY | BESA035L6-HT3B-3035 | 82201108 | AIR COOLED | FINS ARE BAD & DIRTY, DATES BACK 2008 | Bally | BLP312VE-S2B-C0051 |
| 7/16/24 | FM04257 | 10'x10'x8' | 11'x11'x9' | 5'x6' | Yellow | NMNH | NMNH | 11th and Constitution Ave NW Washington DC 20560 | WG-23 | NEXT TO WALK-IN | NO | Yes | Yes | Yes | No | Yes | Yes | -10F | N/A | N/A | Good | N/A | N/A | Good | 2001 | Electrician is working on it. | Electrician is working on it. | Electrician is working on it. | Electrician is working on it. | Yes | Local | Yes | No | Yes | Water sprinkler system | No | BALLY REFRIGERATION | Danfoss Mechanical Thermostat | N/A | N/A | Copeland, MDL# CF09K6E-TF5-271, SN# 07J86495H | N/A | Bally | BEHA025L6-HT3A-F | 82100797 | Air cooled | N/A | Bally | BLP20SLE-S24-SD6NN |
| 7/16/24 | FM04277 | 7'x5'x7' | 8'x15'x8' | 3'x7' | Red | NMNH | NMNH | 12th and Constitution Ave NW Washington DC 20560 | CE-439 | CE-425 | No | NO | Fracilities | Facilities | No | No | No | -10c | N/A | N/A | Good | N/A | N/A | Poor | 2005 | EC4EL1,BREAKERS- 31,33, 15,5 | Good | 20A | YES | No | N/A | No | No | Yes | Water sprinkler system | No | Bally Refrigerated Boxes | Ranco Mechanical T-stat | 010-1000 | N/A | N/A | DATA PLATE IS WARN OFF | HEATCRAFT | BCU1012WBEX6D1 | A05K00034 | WATER COOLED | HAS BEEN OFF FOR OVER A YEAR | Russell | UEU-236 |
| 10/24/24 | FM04601 | 12'10"x12"x8'8" | N/A | N/A | Red | NMNH | NMNH | 13th and Constitution Ave NW Washington DC 20560 | Compost Room By Loading Dock | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Good | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Yes | Water Sprinkler System | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 9/17/24 | FM04371 | 12'8"x31'9"x8'4" | N/A | 3'8"x7'1" | Green | MSC | Museum support Center | 4210 Silver Hill RdSuitland, MD 20746 | 212 | Equipment Room 219 | No | Yes | Yes-OFMR | Yes-OFMR | Need to be badged into walk-in | Yes | Yes | 55F | 27% | N/A | Good | N/A | Good | Good | 2011 | Equipment Room #219, Both system on Panel: EPP-2, System A Breakers: 49,51,53. System B Breakers: 43,45,47 | Good | 35A | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinkler System | Audible & Visual Alarms | Kysor Panel Systems | Siemens Controlled | N/A | N/A | System A Copeland Compressor MDL: EAVA-021E-TDA-220, SN: 10B04475R/ System B Copeland Compressor MDL: EAVA-021E-TAD-220, SN: 10B04474R | N/A | Heatcraft for both systems | System A MDL: WS0210H44/ System B MDL: WS0210H44 | System A SN: A10C00214/ System B SN: A10C002215 | Water Cooled Condensers | Everything is controlled by siemens | Heatcraft | Evaporator 1A MDL: LCA6135BEB, 2A MDL: LCA6135BEB/ 1B Evaporator MDL: LCA6135BEB |
| 9/18/24 | FM04373 | 31'8"x81'5"x9'4" | N/A | 3'8"x7'1" | Yellow | MSC | Museum Support Center | 4211 Silver Hill RdSuitland, MD 20746 | 213 | Equipment Roon 216 | N/A | Yes | Yes-OFMR | Yes-OFMR | Need to be badged to go into walk-in | Yes | Yes | -4F | N/A | N/A | Good | N/A | Good | Good | 2011 | Both systems on Panel EPP-2, System A breakers: 19,21,23. System B breakers: 25,27,29 | Good | 60A | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinkler System | Audible and Visual Alarms | Kysor Panel Systems | Siemens Controlled | N/A | N/A | System A Copeland Compressor 1 MDL: 3DB3F33KE-TFD-200, SN: 10C00578R, Compressor 2 MDL: 3DB3F33KE-TFD-200, SN: 10C00575R/ System B Copeland compressor 1 MDL: 3DB3F33KE-TFD-200, SN: 10C00576R, Compressor 2 MDL: 3DB3F33KE-TFD-200, SN: 10C00577R | Each system has two compressors | HeatCraft for Both Systems | System A & B MDL: LRU2015WBAL6D1 | System A: A10C00294, System B: A10C00295 | Water Cooled Condensers | N/A | Ruskin | All evaporator coils have the same MDL number : CDTI50 |
| 9/17/24 | FM04372 | 31'6"x30'2"x9'4" | N/A | 3'8"x7'1" | Green | MSC | Museum Support Center | 4212 Silver Hill RdSuitland, MD 20746 | 211 | Equipment Room 219 | No | Yes | OFMR | Yes | Need to be badged into walk-in | Yes | Yes | 55F | 27% | N/A | Good | N/A | Good | Good | 2011 | Both systems on Panel: EPP-2, System A Breakers 37,39,41. System B Breakers 31,33,35 | Good | 35A | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinker System | Audible & Visual Alarms | Kysor Panel System | Siemens Controlled | N/A | N/A | System A Copeland Compressor MDL: EAVA-021E-TAD-22, SN: 10B04476R/ System B Copeland Compressor MDL: EAVA-021E-TAD-220, SN:10B04473R | N/A | Heatcraft for both systems | System A MDL: WS0210H44, System B MDL: WS0210H44 | System A SN: A10C00217, System B SN: A10C00216 | Both are Water Cooled | Everything is controlled by Siemens | HeatCraft | System A & B Evaporator MDL: LCA6135BEB |
| 9/18/24 | FM04374 | 15'4"x27'8"x8'9" | N/A | 3'8"x7'1" | Yellow | MSC | Museum Support Center | 4213 Silver Hill RdSuitland, MD 20746 | 148 | On top of Box | N/A | Yes | Yes-OFMR | Yes- OFMR | Need to be badged in | Yes | Yes | 35F | 51% | N/A | Good | N/A | Good | Bubbles | Unknown | Both systems on Panel EPP-2, System A breakers 44,46,48. System B breakers:43,45,57 | Good | 35A | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinkler System | N/A | Environemental Growth Chambers | Siemens Controlled | N/A | N/A | Copeland Compressor System A & B MDL: LACA-032E-TAD-220. System A SN:10B01322R, System B SN: 10B01325R | N/A | HeatCraft for both systems | System A & B MDL: WS0310H4D | System A: A10C00228, System B: A10C00227 | Water Cooled | N/A | Ruskin | CDTI50 |
| 9/19/24 | FM04375 | 9'10"x15'6"x8'9" | N/A | 3'8"x7'1" | Green | MSC | Museum Support Center | 4214 Silver Hill RdSuitland, MD 20746 | 147 | On top of Box | N/A | Yes | Yes-OFMR | Yes- OFMR | Need to be badged in | Yes | Yes | -5 | N/A | N/A | Good | N/A | Good | N/A | Unknown | Both systems on panel EPP-2, System A breakers 26,28,30. System B breakers 20,22,24. | Good | 35A | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinkler System | N/A | Environemental Growth Chambers | Siemens Controlled | N/A | N/A | Both Copeland Compressor MDL: LAHA-032E-TAC-800, System A SN: 00C72220, System B SN: 22H62578R | N/A | HeatCraft for both systems | System A & B MDL: WS0310L63 | System A: A10C00094 System B: A10C00093 | Water Cooled | N/A | Ruskin | CDTI50 |
| 9/19/24 | FM04276 | 8'4"x8'3"x7'2 | N/A | 4'2"x6'7" | Yellow | MSC | Museum Support Center | 4215 Silver Hill RdSuitland, MD 20746 | G1004 | On the roof | N/A | Yes | Yes-OFMR | Yes-OFMR | N/A | Yes | Yes | 38F | N/A | N/A | Good | N/A | N/A | Good | Unknown | Panel: 124 IELI, Breaker: 23 | Good | 20A | Yes | N/A | N/A | N/A | N/A | Yes | Water Sprinkler System | Audible Alarm | Foster Refrigereation Corp. | Johnson Controls | Penn Mechanical Thermostat | N/A | Copeland Compressor MDL: ZS09KAE-TF5-118, SN: 21C5276HL | N/A | Russell | RB0130E4SEB | E172100847 | Air Cooled | N/A | Russell | RL6A117ADA |
| 9/19/24 | FM04267 | 9'1"x6'3"x8'11" | 9x6'7"x9'2" | 3'2"x7'1" | Yellow | MSC | Museum Support Center | 4216 Silver Hill RdSuitland, MD 20746 | G1005 | Roof | No | Yes | OFMR | Yes | Need to be badged into walk-in | Yes | Yes | -20F | N/A | N/A | Good | N/A | Good | Good | Approx. 2002 | Panel: 1L2-SECT-2 / Breakers: CKT30,32,34 / Timer & Controls on same panel but on breakers 33,35 | Good | 50A | Yes | No | N/A | N/A | No | Yes | Water Sprinker System | N/A | Bally EngineeRed Structures | Penn Mechanical | N/A | N/A | Copeland Semi hermetic - MDL:3DA3F28KE-TFC-C00 / SN:22G01194R | N/A | RUSSELL | RFDS06L4SEA | E092300343 | Air Cooled | N/A | RUSSELL | RM6E311DDA |
| 9/23/24 | FM04376 | 13'10"x11'3"x13'4" | N/A | 4'2"x7'1" | Green | MSC | OSTEO PREP LABORATORY | 4217 Silver Hill RdSuitland, MD 20746 | 102 | On the roof | N/A | Yes | Yes-OFMR | Yes-OFMR | N/A | Yes | Yes | 0C | N/A | N/A | Good | N/A | Good | Good | Unkown | Both systems on Panel: ELP1 | Good | 40A | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinkler System | N/A | Bally | Johnson Controls | Penn Mechanical Thermostat | N/A | System A Copeland Compressor MDL: CS20K6E-TF5-256 / SN: 16KAF144M, System B Copeland Compressor MDL: CS12K6E-TF5-256 / SN: 16HCF667M | N/A | Trenton | System A MDL: TEHA035E6-HT3B-B, System B MDL: TEHA020E6-HT3B-B | System A SN: 162405596 System B SN: 162405595 | Air Cooled | N/A | Trenton | System A MDL: TPLP532MAS1BR6-EC2 / System B MDL: TPLP317MAS1BR6-EC2 |
| 9/23/24 | FM04394 | 26'5"x10'11"x13'4" | N/A | 5'2"x7'1" | Green | MSC | OSTEO PREP LABORATORY | 4218 Silver Hill RdSuitland, MD 20746 | 103 | On the roof | N/A | Yes | Yes-OFMR | Yes-OFMR | N/A | Yes | Yes | -20C | N/A | N/A | Good | N/A | Good | Good | Unkown | Both systems on Panel: ELP1 | Good | 40A | Yes | Yes | Local | Yes | Yes | Yes | Water Sprinkler System | N/A | Bally | Johnson Controls | Penn Mechanical Thermostat | N/A | Both Copeland Compressors MDL: 3DF3F40KE-TED-C40, System A SN: 16K03145R, System B SN: 16K03147R | N/A | Trenton | System A MDL: TESA090L6-HT4B-6814, System B MDL: TESA090L6-HT4B-6814 | System A SN: 162405591, System B SN: 162405591 | Air Cooled | N/A | Trenton | System A MDL: TMP348LE-T4A-CC6NN, System B MDL: TMP356LE-T4A-CC6N |
| 9/27/24 | FM04393 | 9'8"x9'1"x7'11" | 9'8"x8'5"x9'8" | 5'11"x6'6" | Yellow | MSC | Osteo Prep laboratory | 4219 Silver Hill RdSuitland, MD 20746 | Inside white fence next to the building | Next to walk-in | Yes | Yes | Yes-OFMR | Yes-OFMR | N/A | Yes | Yes | -20c | N/A | N/A | Poor | N/A | Good | Good | Approx. 2002 | Panel: EPL1 | Good | 40A | Yes | Yes | Local | Yes | N/A | N/A | N/A | N/A | Bally | Johnson Controls | Penn Mechanical Thermostat | N/A | Copeland Scroll MDL: ZF11K4E-TF5-241, SN: 16F8303AD | N/A | Trenton | TEZA035L8-HT3B-6816 | 162405593 | Air Cooled | N/A | Trenton | TPLP314LES2BR6-EC2 |
| 9/27/24 | FM04392 | 9'8"x9'1"x7'11" | 9'8"x8'5"x9'8" | 5'11"x6'6" | Green | MSC | Osteo Prep laboratory | 4220 Silver Hill RdSuitland, MD 20746 | Inside white fence next to the building | Next to walk-in | Yes | Yes | Yes-OFMR | Yes-OFMR | N/A | Yes | Yes | -20c | N/A | N/A | Good | N/A | Good | Good | Approx. 2002 | Panel: EPL1 | Good | 40A | Yes | Yes | Local | Yes | N/A | N/A | N/A | N/A | Bally | Johnson Controls | Penn Mechanical Thermostat | N/A | Copeland Scroll MDL: ZF11K4E-TF5-241, SN: 16F8306A0 | N/A | Trenton | TEZA035L8-HT3B-6816 | 162405594 | Air Cooled | N/A | Trenton | TPLP314LES2BR6-EC2 |
| 10/2/24 | FM04382 | 7'2"10'3" 8'6" | 7'9"11'3"9'2" | 3'7"x7'1" | Green | Smithsonian Gardens Greenhouse Facility | Blue Building inside Greenhouse Facility | 4220 Silver Hill RdSuitland, MD 20746 | Open space by the loading dock | on the outside | N/A | Yes | Possibly OFMR | Possibly OFMR | N/A | Yes | Yes | 38f | N/A | N/A | Good | N/A | N/A | Good | Approx. from 2001 | Disconnect by front door | Good | 30A | Yes | N/A | N/A | Yes | N/A | Yes | Water Sprinkler System | N/A | Bally Refrigeration | Ranco Mechanical Controller | N/A | N/A | Copeland MDL: CR18K6E-TF5-875, SN: 16EAC015M | Good | Bally Refrigeration | BEHA015H2-HT3B-B | 92107650 | Air Cooled | N/A | Bally Refrigeration | BLV150AD-S2B-3016-FD |
| 10/2/24 | FM04398 | 10'6"x22'x8' | N/A | 3'x6'8" | Yellow | Smithsonian Gardens Greenhouse Facility | Building 34 | 4220 Silver Hill RdSuitland, MD 20746 | Room #5 AAG Collection Storage | on the outside | N/A | N/A | Possibly OFMR | Possibly OFMR | N/A | Yes | Yes | 72F | 41% | N/A | Good | N/A | N/A | N/A | Approx. from 2001 | Disconnect by unit. | Good | 30A | N/A | Yes | Local | Yes | N/A | Yes | Water Sprinkler System | N/A | N/A | Siemens | N/A | N/A | N/A Data tag could not be read. | Yellow | Liebert | N/A | N/A | Air Cooled | N/A | Liebert | BLV150AD-S2B-3016-FD |
| 6/13/24 | FM04281 | 22'x34'x10' | N/A | 83"x96" | Green | NZP | Commissary | 3001 Connecticut Ave NWWashington DC 20008 | 172A Freezer 1 | 100M7 | No | Yes | Unknown | HVAC/Facilities may have records | Shoe chemical bath entering commissary. |
Escaped animal codes: Green - Non dangerous
| Red - Dangerous | Yes | Yes | -4 | N/A | N/A | N/A | N/A | Green System 1 1/4 Full |
| System 2 1/2 Full | Green System 1 Full; System 2 Full | 2003 | Room 100M7 |
Panel 4S5 System 1 breaker 2/4/6 System 2 breaker 1/3/5 Green 15a No Yes Local No Yes No N/A Sliding door manual release No visable data tag Siemens N/A N/A Copeland System 1 model - 2DL3-040ETFD200 System 2 model - 2DL3F20KE-TFD-800 System 1 Serial - CCH0513338
| System 2 Serial - 19H60196R | Green | Bally | BW400L6-IT4A-1980 | System 1 - 050304601 | |||||||||||||||||||||||||||||||||||||||||||||
| System 2 - 050304602 | Water cooled | System 1: Yellow - Accumulator is rusted and deteriorating. | |||||||||||||||||||||||||||||||||||||||||||||||
| System 2: Yellow - Condenser head cooling fan is Bad. Accumulator is rusted and deteriorating. | Bally | BB232P-ED-T4B-2423 | System 1 - 050304776 | ||||||||||||||||||||||||||||||||||||||||||||||
| System 2 - 050304777 | Green | No | Green | Green | R-404A | Green | N/A | N/A | Green | Green | N/A | Green | Green | Green | Siemens | N/A | Green | Green | Green | Yellow - Both systems need accumulator reinsulated and 1 length of insulation replaced. | Green | N/A | N/A | Probe within tolerance | Green | N/A | Will quote to replace accumulator and section of insulation on both units, and head cooling fan on system 2 compressor. | ||||||||||||||||||||||
| 6/12/24 | FM04280 | 55'x26'x118" | N/A | Sliding Door - 80"x95"; Person Door - 36"x78" | Green | NZP | Commissary | 3002 Connecticut Ave NWWashington DC 20008 | 172C Vegetable Box | 100M7 | No | Yes | Unknown | HVAC/Facilities may have records | Shoe chemical bath at entrance of commisary. Escaped animal codes: Green - Non dangerous Red - Dangerous | Yes | Yes | 39F | N/A | N/A | N/A | N/A | Green - System 1: 3/4 of sight glass; Green - System 2: 3/4 of sight glass | Green - System 1 Full ; Green - System 2 Full | 2003 | Room 100M7 Panel 4S5 System 1 Breaker 8/10/12 System 2 Breaker 31/33/35 | Green | System 1 20A System 2 15A | No | Yes | Local | No | Yes | Yes | Water | Push bar for person door. Manual release for sliding door. | Bally | Bmil | 82-0372 | 05I-LL3-00108B | Copeland Model - ZDL3R78KE-TFD-800 Serial - ZDL3-075ETFD200 | Green | Bally | BW750M8-IT4A-1978 | System 1 - 050304598 System 2 - 050304597 | Water Cooled | System 1: Red - System intermittently short cycling due to going off on head pressure. Opened water regulating valve fully, no change. | ||
| System 2: Green | Bally | BB374P-A-T4B-T52A1 | System 1 - 050304774 System 2 - 050304775 | Green | No | No | Green | System 1 R448A ; System 2 R-22 | Green | Green | N/A | Yellow - Sliding door opener is off at switch, door must be opened manually. Customer stated another contractor is working on repair. | Yellow - Person door sweep is torn. | N/A | Green | Green | Green | N/A | Sliding door motor replaced | Green | Green | Green | Yellow - 3 lengths of insulation on drain needs replaced | Yellow - 13 bulbs need replaced | N/A | N/A | Probes within tolerance | Green | Customer stated they saw system 1 short cycling. Unit is currently holding temp, charge is Good and unit is not currently short cycling. | Drain line needs 3 lengths of insulation replaced. Person door needs door sweep replaced. 13 Light bulbs need replaced. Replace system 2 condenser and evap in order to convert refrigerant from R-22 to R448A. System 1 needs water cooled condenser cleaned and further evaluated. | |||||||||||||||||||
| 6/17/24 | FM04322 | 9'x15'x12' | N/A | 5'x11' | Green | NZP | Necropsy Bldg | 3003 Connecticut Ave NWWashington DC 20008 | Necropsy Lab Space | Outside of building | No | Yes | Possible Facilities | Possible Facilities | N/A | Yes | Yes | 4c | N/A | N/A | Good | N/A | N/A | Good | Unknown | Panel: NE1 Breakers: 13,15,17 | Good | 20A | Yes | Yes | Local | Yes | No | Yes | Sprinkler System | N/A | Unknown | Johnson Controls | Penn Mechanical T-Stat | N/A | Copeland MDL# ZS13KAE-TF5-118, SN# 22D5128GL | Good | Trenton | TEZA015H8-HT3D-8 | 229241858 | Air cooled | Good | Trenton | |
| 6/17/24 | FM04321 | 16'x34'9' | N/A | 7'x8' | Yellow | NZP | Commissary | 3004 Connecticut Ave NWWashington DC 20008 | FZR 2 172B | 100 M7 | N/A | Yes | Possible Facilities | Possible Facilities | Animal Escaped alarm | Yes | Yes | -20C | N/A | N/A | Good | N/A | Good | Good | Unknown | Panel: 4SF Breakes: 37,39,41/38,40,42 | Good | 20A | Yes | Yes | Local | Yes | Yes | N/A | N/A | N/A | Part of Bldg | Controlled Remotley Through Siemens | N/A | N/A | Copeland MDL# 3DB3F33KE-TFD-800 | Good | Bally | BW750L6-IT4A-1979 | 050304599, 050304600 | Water Cooled | N/A | Bally | |
| 6/12/24 | FM04286 | 7.5x'16.5'x11.5' | N/A | 36'x96.5" | Yellow | NZP | Commissary | 3005 Connecticut Ave NWWashington DC 20008 | 174A Banana Box | 100M7 | No | Yes | Unknown | HVAC/Facilities may have records | Shoe Chemical bath at entrance to commisary. Escaped animal codes: Green - Non-dangerous Red - Dangerous | No | Yes | 55F | N/A | N/A | N/A | N/A | Green 3/4 Sight glass | Full | 2004 | Room 100M7 Panel 4S5 Breaker 26/28/30 | Green | 15A | No | Yes | Local | No | No | Yes | Water | Push button on interior of door | Part of building | Penn | A421 | N/A | Copeland Model - ERFA-031E-TAD-800 Serial - 20L60207R | Green | Bally | BW300M8-IT4A-2021 | 50401622 | Water Cooled | Yellow - Was tripped on head pressure, reset and now operating | Bally | |
| 6/13/24 | FM04279 | 46'x31'/22.5'x10.5' | N/A | Double door to box - 83"x96" ; Single door to 172A - 83"x96"; Single door to 172B - 83"x96"; Single door to 172C - 83"x96" | Yellow | NZP | Commissary | 3006 Connecticut Ave NWWashington DC 20008 | 172 Meat Prep Room | 100M7 | No | Yes | Unknown | HVAC/Facilities may have records | Shoe chemical bath entering commissary. Escaped animal codes: Green - Non dangerous Red - Dangerous | ||||||||||||||||||||||||||||||||||
| Emergency phone. | Yes | Yes | 38F | N/A | N/A | N/A | N/A | Green System 1 half full ; System 2 half full | System 1 Full; System 2 Full | 2004 | Room 100M7 Panel 4S5 System 1 Breaker 14/16/18 System 2 Breaker 26/28/30 | Green | system 1 15a System 2 15a | No | Yes | Local | No | Yes | Yes | Water | Push bar on main entrance door | Part of building | Bmil | 82-0526-00 | 18F82-0526-00-00340H02F650 | Copeland Model # ZDC3-050ETFD200 System 1 Serial - CCJ0514010 System 2 Serial - CCJ0514009 | Green | Bally | BW500M8-IT4A-2020 | System 1 - 050401620 System 2 - 050401619 | Water cooled | Green | Bally | BA255P-A-S1A-TSM2A1 | System 1a Serial - 050401973 System 1b Serial - 050401976 System 2a Serial - 050401974 System 2B Serial - 050401975 | Green | No | N/A | Green | R-22 | Green | Green | N/A | N/A | Green | N/A | Green | Green | Yellow - Has possible water leak in a small spot near main door. Leak is coveRed up with tape and plastic. Ceiling is part of the building. |
| 6/13/24 | FM04278 | 14.5'x7.5'x11.5' | N/A | 35 3/4"x96" | Red | NZP | Commissary | 3007 Connecticut Ave NWWashington DC 20008 | 174 | 100M7 | No | No | Unknown | HVAC/Facilities may have records | Chemical shoe bath entering commisary. Escaped animal codes: Green - Non Dangerous Red - Dangerous | No | No | 40F | N/A | N/A | N/A | N/A | Yellow - Bottom of glass (may be due to running low on gas, oil should return to compressor once back online) | Red | 2004 | Room 100M7 Panel 4S5 Breaker 25/27/29 | Green | 15A | No | Yes | Local | No | No | Yes | Water | Push button inside door | Part of building | Danfoss | AD169-00 | N/A | Copeland Model - ERFA-031E-TAD-800 Serial - 21B62100R | Unknown | Bally | BW300M8-IT4A-221 | 50401621 | Water cooled | unknown | Bally | |
| 6/26/24 | 91284 | 11'x11'x7' | N/A | 3'x8' | Yellow | NZP | Research Building | 3008 Connecticut Ave NWWashington DC 20008 | 1st Floor Hallway | On the roof | No | Yes | Facilities | Yes | No | Yes | Yes | -18F | N/A | N/A | Good | N/A | N/A | R448A | Unknown | Panel: PNL-PCC, Breaker 31 | Good | 20A | Yes | Yes | Local | yes | No | No | N/A | N/A | Bally | Johnson Controls | Penn Mechanical Thermostat | N/A | Copeland MDL# ZF08K4E, SN# 16G2126AD | N/A | Trenton | TEZA025L8-HT3B-F | 160352531T | Air Cooled | N/A | Trenton | |
| 6/25/24 | 91286 | 7'X4'X6 | N/A | 3'X6' | Yellow | NZP | Research Building | 3009 Connecticut Ave NWWashington DC 20008 | B05/Migration Bird Center Lab | On top of the box | N/A | Yes | Facilities | Facilities | N/A | Yes | Yes | 40F | N/A | N/A | Poor | N/A | N/A | Bubbles | Unkown | Panel: PNL-PA, Breaker: 13,15 | Good | Unknown | Yes | No | N/A | No | No | Yes | Sprinkler System | N/A | N/A | Johnson Controls | Penn Mechanical Thermostat | N/A | Tecumseh MDL: AK168AT-038-PZ, SN: AKA446OYAA | N/A | Tecumseh | AKA4460YXAXC | 0A81074222 | Air Cooled | N/A | BOHN | |
| 6/26/24 | 91209 | 11'x6'x8' | N/A | 3'x8' | Yellow | NZP | Research Building | 3010 Connecticut Ave NWWashington DC 20008 | 1st Floor Hallway | On the roof | No | Yes | Possibly facilities | Yes | N/A | Yes | Yes | 40F | N/A | N/A | Good | N/A | N/A | Good | Unkown | Unknown | Good | Unkown | Yes | Yes | Local | Yes | No | Yes | Sprinkler System | No | Bally | ESP Controller on Evaporator | ESP+ | N/A | Copeland Mdl# ZB07KAE-TF5-118, SN# 20G17E62L | N/A | Trenton | TEZA008H8-HT3D-B | 209447802 | Air Cooled | N/A | Trenton | |
| 6/25/24 | FM04400 | 11'X9'7 | 12'X10'X8' | 3'X6' | Red | NZP | Research Bldg | 3011 Connecticut Ave NWWashington DC 20008 | Outside | On top of box | Yes | No | Possibly facilities | Possibly facilities | No | No | No | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Unkown | Poor | Unkown | N/A | Yes | Local | N/A | No | No | No | N/A | CrownTonka | Johnson Controls | Penn Mechanical Thermostat | N/A | Copeland | Poor | Russell | RLO400L44-E | G04257416-0101 | Air Cooled | N/A | Russel | |
| 6/25/24 | 6414 | 7'x7'x8' | N/A | 3'x6' | Red | NZP | Vet Hospital | 3012 Connecticut Ave NWWashington DC 20008 | Hallway | On top of Box | No | No | Unknown | Unknown | No | No | No | N/A | N/A | N/A | N/A | N/A | N/A | N/A | All Equipment ManufacteRed in 87', Box manufactuRed is unknown | Panel: ELA RM213 Breaker: 31-35 | N/A | 15A | No | N/A | N/A | N/A | N/A | Yes | Sprinkler System | N/A | N/A | Johnson Controls | Penn Mechanical T-stat | N/A | Copeland MDL# KALA-0150-TAC, SN# 91F-74 | N/A | Copeland | C7AB-0150-TAC-001 | 02K87 | Air Cooled | N/A | BOHN | |
| 6/26/24 | 4395 | 5'1" x 5'1" x 6'10" | 5'9" x 5'9" x 7'2" | 3' x 6'5" | Red | NZP | Lion & Tiger Building | 3013 Connecticut Ave NWWashington DC 20008 | Big Cat's Kitchen | Next to Walk-In | No | No | Unknown | Unknown | No | No | Unit has been turn off for some time. | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Condenser dates back to 99' | Panel 2A, Breaker 27&28 | Poor | 30amp | Yes | No | N/A | N/A | No | No | N/A | No | Unknown | Johnson Controls Mechanical Thermostat | Penn | N/A | Copeland | MDL# CS14K6E-PFV-273, SN# 99FH7291H, 208V | Copeland | FJAL-A200-CFV-001 | 09G99 | Air Cooled | 208-230v | HeatCraft | |
| 6/26/24 | 4396 | 7'2" x 5'5" x 7' | 7'10" x 6' x 8' | 3'x 6'7' | Yellow | NZP | Great Apes Building | 3014 Connecticut Ave NWWashington DC 20008 | Kitchen | Next to Walk-In | No | Yes | Unknown | Unknown | No | Yes | Yes | F | N/A | N/A | Okay | N/A | N/A | Bubbles | Unknown | Panel PNL LVAA, Breaker 37, Panel In hallway. | Okay | 20 | Yes | No | N/A | No | No | Yes | Water Sprinkler | No | Artic, Walk-in MDL# 40 5.10x7.10, SN# 22089 | Saginomiya Mechanical Thermostat | N/A | N/A | Copeland | Compressor MDL# RST55C1E-CAV-109, SN# 1022736, 208-230V | Copeland | M4FF-0075-CAV-020 | 10E407020 | Air Cooled | 208-230V | KeepRite | |
| 9/5/24 | FM04349 | 7'1"x13'2"x7'6" | 8'x14'x8'4" | 3'x6'7" | Green | SCBI | 245 | 1500 Remount Rd, Front Royal, VA 22630 | Outside next to building | On top of box | Yes | Yes | OFMR | OFMR | NO | Yes | Yes | -10F | N/A | N/A | Good | N/A | Good | Good | Approx. 03/2024 | Unknown | Good | Unknown | Yes | Yes | Local | Yes | No | No | N/A | No | Polar king | thermsolutions | KE2 | N/A | ZF11K4E-PFV-231 | Brand new | Copeland | FFAL-A26Z-CFV-075 | 23HA0089U | Air cooled | Brand new | Heat transfer product group | |
| 9/4/24 | FM00715 | 7'1"x10'11'x7'10" | 7'9"x11'7"x8'6" | 3'2x6'6" | Yellow | SCBI | Research Biorepository Lab | 1501 Remount Rd, Front Royal, VA 22630 | Outside towards the left side of the building | On top of box | Yes | No | OFMR | OFMR | No | No | No | -10F | N/A | N/A | N/A | N/A | N//A | N/A | Unknown | Unknown | Good | Unknown | Yes | YES | Local | Yes | No | No | N/A | N/A | Standex Refrigeration | Johnson Controls | Penn | N/A | Copeland MDL# CF09K6E-PFV-295, SN# 18KAN037M | N/A | Copeland | CPF200DC0-A | 19060125 | Air Cooled | System is a package unit | N/A | |
| 9/4/24 | FM03981 | 10'x12'10"x6'9" | 11'7"x13'6"x7'5.5" | 36"74" | Red | SCBI | Commissary | 1502 Remount Rd, Front Royal, VA 22630 | 133 MDP | On top of the box | N/A | Yes | OFMR | OFMR | No | Yes | Yes | 34F | N/A | N/A | Good | N/A | N/A | Has Bubbles | Approx. from 2005 | Panel: 701 0133 Breakers: 32,34,36 | Good | 30A | Yes | Yes | Local | No | No | No | N/A | N/A | W.A.Brown & Son, INC | Johnson Controls | Penn | N/A | Copeland, MDL: CS10K6E-TF5-277, SN# 05A20650H | N/A | Copeland | FTAH-A101-TFC-001 | 27A05 | Air Cooled | N/A | HeatCraft | |
| 9/4/24 | 90320 | 7'1"X6'1"X6'9" | 7'9-1/2"X6'9-1/2"X7'6" | 36"X73" | Yellow | SCBI | 133/commisary | 1503 Remount Rd, Front Royal, VA 22630 | Commisary | On top of box | No | Yes | N/A | N/A | N/A | Yes | Yes | 8f | N/A | N/A | Yes | N/A | N/A | Half full | N/A | Panel-701 0133 breakers 27 25 29 | Good | 30 amp | No | Yes | Local | Yes | No | No | N/A | No | W.A. BROWN & SON,INC | White-Rodgers | N/A | N/A | Copeland MDL-CF06K6E-TF5-253 | Bad-roto lock rusted | Copeland | FJAL-B200_TFC-001 | 08C20044U | Aircooled | Good | Trenton | |
| 9/5/24 | FM04269 | 5'2"x7'2"x6'10" | 5'10"x7'10"x7'6" | 3'x6'5" | Green | SCBI | Outside Vet Hospital | 1504 Remount Rd, Front Royal, VA 22630 | Outside Front | Mounted behind the walk-in | Yes | Yes | Unknown | Unknown | No | Yes | Yes | 37F | N/A | N/A | Yes | N/A | N/A | Good | Approx. 2007 | Breakers located on the box by the condenser | Good | 20A | Yes | Yes | Local | No | No | No | N/A | N/A | U.S. Cooler | Johnson Controls | Penn | N/A | Copeland MDL# RS47C2-IAV-101, SN# 07G31808B | N/A | Copeland | F3AH-A078-IAV-020 | 07H40296U | Air Cooled | N/A | HTP SCOTTSBORO | |
| 8/27/24 | FM04258 | 11'3x9'7x8'10 | 10'2x10'1x9'2 | 3'2x6'6 | Green | SERC | Charles Mathias Laboratory Building 100 | 647 Contees Wharf RdEdgewater, MD 21037 | 16 | On top of box | No | Yes | Yes-OFMR | Yes-OFMR | No | Yes | Yes | 28.0c | N/A | N/A | N/A | N/A | N/A | Good | Approx. 29JAN2013 | Panel: A-LAB-B1W, Breakers: 31,33,35 & 37,39,41 | Good | 20A & 30A | Yes | Yes | Local | Yes | No | Yes | Water Sprinkler System | N/A | Environmental Growth Chambers | EGC | TC2 | N/A | Copeland Reciprocating MDL#RST70C1E-TA5-959 SN#24B02302E | N/A | Heatcraft | HWN010X6C | T13A06396 | Water Cooled | N/A | N/A | |
| 8/28/24 | FM04366 | 11'3x9'8x8'11 | 10'2x10'1x9'2 | 3'2x6'7 | Green | SERC | Charles Mathias Laboratory Building 100 | 648 Contees Wharf RdEdgewater, MD 21037 | 18 | On top of box | No | Yes | Yes-OFMR | Yes-OFMR | No | Yes | Yes | 20.0c | N/A | N/A | N/A | N/A | N/A | Good | Approx. 29JAN2013 | Panel: A-LAB-B1W, Breakers: 32,34,36 & 38,40,42 | Good | 20A & 30A | Yes | Yes | Local | Yes | No | Yes | Water Sprinkler System | N/A | Environmental Growth Chambers | EGC | TC2 | N/A | Copeland Reciprocating MDL#RST70C1E-TA5-211 S#16K004823E | N/A | Heatcraft | HWN0100X6C | T17A09924 | Water Cooled | N/A | N/A | |
| 8/28/24 | FM04366 | 11'3x9'8x8'11 | 10'2x10'1x9'2 | 3'2x6'7 | Green | SERC | Charles Mathias Laboratory Building 100 | 649 Contees Wharf RdEdgewater, MD 21037 | 20 | On top of box | No | Yes | Yes-OFMR | Yes-OFMR | No | Yes | Yes | 18.0c | N/A | N/A | N/A | N/A | N/A | Good | Approx. 29JAN2013 | Panel: AP-B1, Breakers: 29,31,33 & 35,37,39 | Good | 20A & 30A | Yes | Yes | Local | Yes | No | Yes | Water Sprinkler System | N/A | Environmental Growth Chambers | EGC | TC2 | N/A | Copeland Reciprocating MDL# RST70C1E-TA5-959, SN# 18B05587E | N/A | Heatcraft | HWN010X6C | T13A06394 | Water Cooled | N/A | N/A | |
| 8/13/24 | FMO4365 | 7'7"x7'9.5"x8'4 | 9'Wx8'8"H | 3'3"Wx6'6" | Green | SERC | Charles Mathias Laboratory Building 100 | 650 Contees Wharf RdEdgewater, MD 21037 | 1022 | On top of Box | N/A | Yes | Yes-OFMR | Yes- OFMR | No | Yes | Yes | 4C | N/A | N/A | Good | N/A | N/A | Good | 29-Jan-13 | Panel: A-LAB-1W5, Breakers: 13,15,17 & 19,21,23 | Good | 30A | Yes | Yes | Local | Yes | No | Yes | Water Sprinkler System | N/A | Environmental Growth Chamber MDL#2173-1, SIZE: 36P78 | Environmental Growth Chanber Controler | EGC- TC2 | N/A | Copeland MDL# RST70C1E-TA5-959, SN# 19J09981E | N/A | Heatcraft | HWN010X6C | T13A06397 | Water Cooled Condenser | N/A | Heatcraft | |
| 8/13/24 | FM04364 | 7'5x8'4x10'10 | 8'8xN/Ax8x8 | 3'2"x6'6" | Green | SERC | Charles Mathias Laboratory Building 100 | 651 Contees Wharf RdEdgewater, MD 21037 | 2024 | On | No | Yes | Yes-OFMR | Yes-OFMR | No | Yes | Yes | 4c | N/A | N/A | Poor | N/A | N/A | Good | 29-Jan-13 | Panel: A-LAB-2W6, Breakers: 11,13,15 & 17,19,21 | Good | 20A & 30A | Yes | Yes | Local | Yes | No | Yes | Water Sprinkler System | N/A | Environmental Growth Chambers | Environmental Growth Chambers | EGC-TC2 | N/A | Copeland MDL# RST70C1E-TA5-211, SN# 12L06382E | N/A | HEATCRAFT | HWN010X6C | T13A06395 | Water Cooled | N/A | Heatcraft | |
| 8/27/24 | FM04350 | 6'1'x8'5"x6'11" | 8'3"x9'x8'7" | 3'3"x6'6" | Green | SERC | Charles Mathias Laboratory Buiding 100 | 652 Contees Wharf RdEdgewater, MD 21037 | 6 | On top of the box | No | Yes | Yes-OFMR | Yes-OFMR | No | Yes | Yes | 4.0C | N/A | N/A | N/A | N/A | Good | Good | Approx. 89' | Breaker Panel Located in front of the box | Good | 10A & 15A | Yes | Yes | Local | Yes | No | No | N/A | N/A | Percival Scientific | Percival Scientific | Series 101 | N/A | Copeland Scroll MDL# ZB21KCE-TF5-240, SN# 14G5954AD | N/A | Keeprite Refrigeration | KXZA030H8-IT3A-19830 | 142404642 | Water Cooled | N/A | N/A | |
| 8/14/24 | FM04352 | 7'4"x8'4"x7' | 9'xN/Ax8'7" | 3'3"x6'3" | Green | SERC | Charles Mathias Laboratory Building 100 | 653 Contees Wharf RdEdgewater, MD 21037 | 10 | On | No | Yes | Yes-OFMR | Yes-OFMR | No | Yes | Yes | -10F | N/A | N/A | Good | N/A | N/A | Good | 29-Jan-13 | There is a panel attached on the front of the box on breakers 2, 3, 4, 5, 8 6. This panel receives power from panel BSMT - PP In Room 0017 on breakers 23, 25, & 27. | Good | 30A | Yes | Yes | Local | Yes | No | N/A | N/A | N/A | Norlake Scientific | MasterBilt / Refrigerated Solutions Group | 05-02585 | E332201164 | Copeland M#ZF06KAE-TF5-118 S#22108C07L | This compressor has liquid injection | Norlake Scientific | MS2232966 | 22110061 | Air Cooled | N/A | MasterBilt / Refrigerated Solutions Group | |
| 8/14/24 | FM04351 | 6'9"x8'4"x6'11" | 8'1'"N/Ax9' | 3'3"x6'6" | Green | SERC | Charles Mathias Labortory Building 100 | 654 Contees Wharf RdEdgewater, MD 21037 | 8 | On top of box | No | Yes | Yes-OFMR | Yes-OFMR | No | Yes | Yes | 15.0c | N/A | N/A | N/A | N/A | N/A | Good | Approx 20+Years | Breaker Panel located in front of the box | Good | 10A&15A | Yes | Yes | Local | Yes | No | No | N/A | N/A | Percival Scientific | Percival Scientific | Series 101 | N/A | Copeland M#ZS11KAE-TF5-118 S#14J83F06L | N/A | KeepRite Refrigeration | KXZA011H8-iT3A-19831 | 142404643 | Water Cooled | N/A | N/A | |