25-0011 SID.pdf
PDF 5 MB Posted
- Attached to
- Repair BEQ HP135
- Solicitation number
- N4008526R9044
About this file
This is a Structural Interior Design (SID) Package for the HP135 BEQ (Bachelor Enlisted Quarters) Renovation at Marine Corps Base Camp Lejeune, North Carolina, submitted as a sealed final submittal in May 2026.
The design package establishes comprehensive interior finish standards for the barracks renovation project, with finishes selected for high durability and low maintenance requirements. Flooring specifications include luxury vinyl tile (LVT-1, Mannington Crisscross in Charcoal) for sleeping quarters and office spaces; epoxy resinous flooring (RES-1, Sherwin Williams Deco Quartz in Caterpillar) for common lounge areas; porcelain tile (T-1, Crossville Shade 2.0 in Thunder) for bathroom and janitor floors; quarry tile (T-4, Daltile Arid Flash) for kitchen areas; and sealed concrete for laundry rooms, corridors, and utility spaces. Wall finishes consist of painted CMU and drywall (PNT-1, Benjamin Moore Classic Grey) with accent walls in sleeping rooms (PNT-2, Benjamin Moore River Reflections), bathroom wall tile (T-2 and T-3, Atlas Concorde Element Gray), and porcelain tile accent bands in toilet rooms. Additional specifications include rubber base trim (RB-1, Tarkett Mink WG), solid surface countertops and window sills (SS-1 and SS-2, Corian Neutral Aggregate), solid surface shower surrounds (SS-3, Corian Glacier White), fiberglass reinforced plastic (FRP-1, Marlite Pebbled Light Grey), casework in plastic laminate (PLAM-1, Formica Blackened Legno), and window shades (WS-1 and WS-2, Read Window Products). Interior signage utilizes 2/90 Sign Systems with tactile lettering and Grade 2 Braille throughout the facility. The project complies with FC 1-300-09N Navy & Marine Corps Design Requirements, UFC 1-200-01 DoD Building Code, UFC 3-120-01 Design Sign Standards, UFC 3-120-10 Interior Design, and UFC 3-190-06 Protective Coatings and Paints. The design underwent 50% and 95% review phases with final submission scheduled for April 2, 2026.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
interior design within
HP135 BEQ Renovation CL Marine Corps Base, Camp Lejeune, NC
Structural Interior Design Package Sealed Final Submittal May 2026
HP135 BEQ Renovation CL Marine Corps Base, Camp Lejeune, NC Structural Interior Design Package interior design within
Table of Contents
1. Point of Contact List
2. Narrative of Interior Design Objectives
3. Meeting Minutes
4. Finish Plans & Schedules
5. Finish Boards
Structural Interior Design Package interior design within
Point of Contact List A&E Architect John Schmied, AIA, LEED AP BD+C MBF Architects 317-C Pollock Street New Bern, NC 28560
(252) 637-6373 schmied@mbfarchitects.com
A&E Interior Designer Jamie Kissel, NCIDQ, CID Within Interior Design 1008 Granby Street Norfolk, VA 23510
(757) 224-0489 jkissel@withindesigns.com
Base Architectural Supervisor Cathy Martin Architectural Design Branch/Public Works Division 1005 Michael Road Camp Lejeune, North Carolina 28547
(910) 451-0394 catherine.martin@usmc.mil
Structural Interior Design Package interior design within
SID Narrative
INTERIOR DESIGN CRITERIA
Interior Design work will comply with the latest edition of the following codes and standards:
FC 1-300-09N Navy & Marine Corps Design Requirements UFC 1-200-01 DoD Building Code UFC 3-120-01 Design: Sign Standards UFC 3-120-10 Interior Design UFC 3-190-06 Protective Coatings and Paints
INTERIOR BASIS OF DESIGN
This Basis of Design Narrative outlines the proposed Structural Interior Design requirements for Repairs to BEQ HP135 at United States Marine Corps Base, Camp Lejeune. The interior finishes are the most exposed interior elements in a building and must be durable to withstand the daily traffic and demands of the environment. To meet these objectives, the SID package will use all the general requirements for interior finishes that have been applied in similar facilities recently constructed at MCB Camp Lejeune, as well as best practices recommended by manufacturers for areas requiring enhanced durability. Structural finishes in accordance with the following guidelines will provide longevity and timeless aesthetics without compromising the functional integrity of the facility.
Finishes will be selected because of their high durability and low maintenance requirements.
Luxury vinyl tile flooring will be used in sleeping quarters and office spaces, while common lounge areas will receive epoxy resinous flooring. Porcelain tile will cover the floors in the head/ shower rooms. The laundry rooms corridors and utility spaces on all floors will receive sealed concrete floors.
Interior partitions will be painted CMU & drywall. Accent walls will be painted in sleeping rooms to provide visual variety. Offices will recieve a solid accent wall while toilet rooms will recieve porcelain tile with a porcelain tile accent band. All wall finishes will be cohesive to adjacent spaces and provide a fresh and upgraded look. Drywall and exposed ceilings will also have a painted finish.
Interior signage will be provided throughout the facility to form a well-organized, comprehensive interior environment that guides users and visitors through the building. Interior Signage will include identification, directional, and informational systems utilizing permanent and changeable signage.
Structural Interior Design Package interior design
Meeting Minutes
1 | P a g e
1008 Granby Street | Norfolk, VA 23510 | 757.224.0489
MEETING MINUTES
Project: Repair BEQ HP135 Meeting: 50% Review Meeting Date: December 18th, 2025 Location: Microsoft Teams Meeting
PROJECT TEAM IN ATTENDANCE:
Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489
Below are the items that were addressed at the 50% Review Meeting.
50% REVIEW COMMENTS
REVIEWER: TREAVOR STREETER
Item #13 I-501: Reflect the accessible sign design, layout, and fonts as additional typical signage details.
Response: Clarify during review meeting.
Clarify with John from MBF.
Item #18 Overall Note: Ensure sleeping rooms are outfitted for 2 occupants, not 3. Double-check furniture and life safety layouts reflect this.
Response: Furniture is not part of the interiors scope. MBF to coordinate.
Item #58 I-101: Grid linetype bleeds into the closet in sleeping room 101. Linetype is trimmed in a couple closets but not the others. Come up with a standard for showing different materials through linetypes and weights, they should all be consistently marked/displayed.
Response: Concur. Line weights will be edited.
Item #59 I-101: Trim additional lines bleeding into surfaces and furniture.
Response: Concur. Drawings will be cleaned up.
2 | P a g e
Item #60 I-111 – I-113: Include stairwell sign locations for interior stairwells on these sheets. I see they are added later, but to keep it consistent, add to overall plans, not just the enlarged ones.
Response: Concur. Stairwell signage will be added to overall furniture plans on each floor.
Item #61 I-202: Label grout joint thickness. Also, include callout for silicone caulk for interior transitions from tile to tile (Like at the base of detail A1). Grout will crack and separate, caulking will last much longer and be better for long-term water proofing.
Response: Concur. Annotations will be added.
Item #62 I-601: Pnt-3 is called out for Duty room 146 and all typical sleeping rooms, but there is no
Pnt-3 listed on the finish legend. Coordinate interior design selections to room usage and rectify this discrepancy.
Response: Concur. Correction will be made to PNT-3.
ACTION ITEMS
1. 95% Submittal due to government on 2/9/26.
INTERIOR DESIGN
1 | P a g e
1008 Granby Street | Norfolk, VA 23510 | 757.224.0489
MEETING MINUTES
Project: Repair BEQ HP135 Meeting: Pre-Final Review Meeting Date: March 4th, 2026 Location: 1005 Michael Road
PROJECT TEAM IN ATTENDANCE:
Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489
Below are the items that were addressed at the 95% Review Meeting.
95% REVIEW COMMENTS
REVIEWER: TREAVOR STREETER
Item #11 A-601/I-101: Include sill for door 138, concrete flooring in the vending/corridor area changes to Resilient flooring in the kitchen and is not "technically" combustible-proof.
Response: Kitchen flooring will be changed to quarry tile (WID)
Item #12 I-102: Missing linework for the wall between 240 and 248 + 340 and 348.
Response: Concur. Graphics will be reviewed.
Item #18 I-101: Closets in rooms 100 and 102 have no lineweights under the shelving, add the lvt floor hatching there.
Response: Concur. Graphics will be reviewed.
Item #19 I-202: Grout joint thickness was not called out for, which was confirmed in the 50% comments.
Response: Concur. 1/8" grout thickness has been added to detail A1 and A3 on I-202.
Item #22 I-101: Laundry Room 148 has diagonal lines notating (I assume) the dropped ceiling, but if we're just showing the flooring, can we omit the lines so as not to confuse the flooring sub?
2 | P a g e
Response: Concur. Ceiling has been hidden in the view
Item #23 SID: I-103: For room 305, Have the shower surround touch the north of the sleeping room bathroom. There's a small gap showing the tile floor as opposed to being only the shower enclosure.
Response: Concur. To be coordinated with Architecture.
Item #24 SID: I-101/102/103: Missing door cutouts in the lounge (348) room, and linen storage (346), Mechanical Corridor 350 near the exit stairwell, Mechanical Corridor 349 near the exit stairwell, Mechanical Corridor (249), Lounge (248), Laundry (242), Mechanical Corridor (250) near the exit stairwell, Mechanical Corridor (149) both sides of entry/exit of the corridor, Laundry (148), Stair (141), Laundry (142), Duty (146), Electrical (144), Mechanical Corridor
(150) both sides of entry/exit of corridor. Just looking for similar programmed materials to be shown the same way throughout the drawing documents.
Response: Concur. Cut planes will be reviewed and corrected.
Item #25 SID: I-101: Inconsistent portrayal of bathroom fixtures, ensure all toilet rooms and sleeping rooms have the same fixtures detailed. For example, toilet 143 shows all fixtures needed in the bathroom, toilet 243 only shows a toilet and sink, toilet 343 also only shows sink and toilet.
Response: Concur. To be coordinated with Architecture.
Item #26 SID: I-201: Add additional Finish Note: "LVT flooring coverage includes the entirety of the sleeping room, and continues into the wardrobes of each sleeping room."
Response: Concur. Note has been added.
Item #27 SID: I-202: Are we going to have a schleuter or quarter-round for the top edge of the janitor room tile where it meets the drywall? (A3), it'll be an unfinished edge with a caulking seam covering a 2-tone porcelain tile. Call out the transition strip (preferable), or call out the caulking/grout seam. If using a metal transition strip, match the color/finish to the Satin Anodized that the other tile-to-tile, tile-to-finished surfaces are calling for.
Response: A3/I-202 references detail A4/I-502 which is a schluter strip transition at janitor walls.
Item #28 SID: Sheet A-601/I-101: Include sill for door 138, concrete flooring in the vending/corridor area changes to Resilient flooring in the kitchen and is not "technically" combustible-proof.
Recently, this comment has inspired a change to quarry tile in the kitchen. Let's reflect this so as to keep some consistent design elements. 8"x8" throughbody, unglazed quarry tile in a medium/light grey tone. Cove base and inside cove corners included too.
Response: Concur. Kitchen flooring will be changed to quarry tile
Item #29 SID: Sheet I-102: Missing linework for the wall between 240 and 248 + 340 and 348.
Response: Concur. Concur. Graphics will be reviewed.
Item #30 SID: Sheet I-101: Closets in room 100 and 102 have no lineweights under the shelving, add the lvt floor hatching there.
3 | P a g e
Response: Concur. Graphics will be reviewed.
Item #31 SID: Sheet I-202: Grout joint thickness was not called out for, which was confirmed in the 50% comments. Please include proposed grout thickness on detail A1, I-202 (hopefully 1/8"). I see it is included in the finish notes on I-601, but I'd like it visually noted on A1, I-
202. This is where the sub will probably stop, look, and start installing. Let's get it noted earlier.
Response: Concur. 1/8" grout thickness has been added to detail A1 and A3 on I-202.
Item #32 SID: Sheet I-501: Drop the "2" on sign S3 a few ticks so that the number is fully legible.
Center it vertically between "Floor" and "Rooms 230-240"
Response: Concur. Concur. 5" tactile number has been adjusted.
Item #33 SID: Sheet I-501: Drop the "A" on sign S8 a few ticks so that the letter is inside of the 8" delineation. Consider dropping the stair and the letter by a few ticks so as to make things fit without squeezing the white space.
Response: Concur. This is a result of some graphics issue when printing. The A sits beside STAIR. Grapchics will be reviewed before printing again.
Item #34 SID: Sheet I-601: There is a size listed on the grout choice for Floor tile TL-1 (GR-1) as "3?1"...
change GR-1 and GR-2 to reflect the grout joint thickness for the appropriate surrounding tile.
Response: Concur. Typo has been corrected.
Item #35 SID: GR-1 Epoxy grout looks a touch more brown than the more mauve/grey flooring.
Could we switch the grout color to something that's closer to the hue of the floor while being a touch darker to help hide stains and grime?
Response: Concur. A darker grout will be selected.
Item #36 SID: The base RB-1 "toast 289" also seems to be a touch more mocha than the flooring, could we get something tinted just a touch more grey?
Response: Concur.
Item #37 SID: There are no products shown for the wall tile or the accent tile, cannot give a review on the colors or selections on this or the grout wall tile without having product to compare it to.
Response: Concur. Wall tile imagery will be added to the SID binder.
Item #38 SID: RES-1 should be reselected to coordinate with the accent wall. A few lighter grey/rosewater tones can help make-up the color to transition to the exterior walkways, but I'd like to see a color closer to oatmeals/soft whites/warm greys. -To confirm with Base housing rep Kara Wagner. While awaiting a response, please mock up what this would look like to not have wasted time during selections and the iterative design process.
Response: Concur. Reselection sample will be sent to Kara. Will coordinate address for shipping.
4 | P a g e
ACTION ITEMS
1. Confirm that all 50% and 95% changes are captured in the drawings and SID binder.
SCHEDULE
1. 4/2 is the Final submission to the Govt.
Structural Interior Design Package interior design
Finish Plans & Schedules
FLOOR FINISH KEY
LVT-1
T-1
RES-1
SC-1
RES-2
T-4
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
KITCHEN
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
VENDING
DUTY
CORRIDOR
LAUNDRY
MECHANICAL
MECHANICAL
I-401 B1 I-401
B3 I-401 B6
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-101
APG
JDK
JDK REPAIR BEQ HP135
FIRST FLOOR FINISH PLAN
60042869 N40085-25-B-0011
15 MAY 2026
SCALE: 1/8" = 1'-0"B1 1ST FLOOR FINISH PLAN
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF
DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND
SALIENT CHARACTERISTICS ONLY. THE LISTING OF
MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT
THE SELECTION OF PRODUCTS PROVIDED BY OTHER
MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA
WILL BE CONSIDERED AND MUST BE REVIEWED BY THE
INTERIOR DESIGNER OF RECORD (IDOR) AND THE NAVFAC
INTERIOR DESIGNER AND APPROVED BY THE
CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO
AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY
LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN THE
CENTER OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM
CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL
COLOR. PANELS PAINTED BY BRUSH ARE NOT
ACCEPTABLE
FINISH NOTES
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. INSTALL CORNER GUARDS (CG-1) ON ALL OUTSIDE
CORNERS. INSTALL END WALL PROTECTORS AT OPEN
ENDED WALLS. CORNER GUARDS AND END CAPS MUST BE
FULL HEIGHT AND SHOULD NOT BE USED ON CMU WALLS,
TILED WALLS, OR MANUFACTURED STONE WALLS.
I. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST
INCLUDE METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE
CORNERS AS WELL AS THE INTERSECTION BETWEEN
FLOOR AND WALL TILE WHERE APPLICABLE FOR A
COMPLETE INSTALLATION.
J. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
K. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR
FRAMES TO BE PAINTED (PNT-5). ALL GWB & EXPOSED
CEILINGS TO BE PAINTED (PNT-6).
L. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
M. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
N. ALL TILE TO RECEIVE GROUT FINISH (GR-1).
O. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF
EACH SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY
INTO THE TOILET/SHOWER COMPARTMENT. SEE
ENLARGED PLAN VIEW B1/I-401.
P. SEE I-601 FOR FINISH LEGEND.
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
N E No.
T-1
RES-1
SC-1
RES-2
T-4
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
STORAGE
COMM
CORRIDOR
LOUNGE
MECHANICAL
MECHANICAL
I-401 B5
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-102
APG
JDK
JDK REPAIR BEQ HP135
SECOND FLOOR FINISH PLAN
60042870 N40085-25-B-0011
15 MAY 2026
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"B1 2ND FLOOR FINISH PLAN
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF
DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND
SALIENT CHARACTERISTICS ONLY. THE LISTING OF
MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT
THE SELECTION OF PRODUCTS PROVIDED BY OTHER
MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA
WILL BE CONSIDERED AND MUST BE REVIEWED BY THE
INTERIOR DESIGNER OF RECORD (IDOR) AND THE NAVFAC
INTERIOR DESIGNER AND APPROVED BY THE
CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO
AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY
LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN THE
CENTER OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM
CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL
COLOR. PANELS PAINTED BY BRUSH ARE NOT
ACCEPTABLE
FINISH NOTES
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. INSTALL CORNER GUARDS (CG-1) ON ALL OUTSIDE
CORNERS. INSTALL END WALL PROTECTORS AT OPEN
ENDED WALLS. CORNER GUARDS AND END CAPS MUST BE
FULL HEIGHT AND SHOULD NOT BE USED ON CMU WALLS,
TILED WALLS, OR MANUFACTURED STONE WALLS.
I. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST
INCLUDE METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE
CORNERS AS WELL AS THE INTERSECTION BETWEEN
FLOOR AND WALL TILE WHERE APPLICABLE FOR A
COMPLETE INSTALLATION.
J. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
K. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR
FRAMES TO BE PAINTED (PNT-5). ALL GWB & EXPOSED
CEILINGS TO BE PAINTED (PNT-6).
L. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
M. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
N. ALL TILE TO RECEIVE GROUT FINISH (GR-1).
O. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF
EACH SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY
INTO THE TOILET/SHOWER COMPARTMENT. SEE
ENLARGED PLAN VIEW B1/I-401.
P. SEE I-601 FOR FINISH LEGEND.
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
T-1
RES-1
SC-1
RES-2
T-4
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHCANIAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
MECHANICAL
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
STORAGE
OFFICE
CORRIDOR
LOUNGE
I-401 B5
Sim
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-103
APG
JDK
JDK REPAIR BEQ HP135
THIRD FLOOR FINISH PLAN
60042871 N40085-25-B-0011
15 MAY 2026
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"B1 3RD FLOOR FINISH PLAN
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF
DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND
SALIENT CHARACTERISTICS ONLY. THE LISTING OF
MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT
THE SELECTION OF PRODUCTS PROVIDED BY OTHER
MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA
WILL BE CONSIDERED AND MUST BE REVIEWED BY THE
INTERIOR DESIGNER OF RECORD (IDOR) AND THE NAVFAC
INTERIOR DESIGNER AND APPROVED BY THE
CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO
AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY
LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN THE
CENTER OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM
CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL
COLOR. PANELS PAINTED BY BRUSH ARE NOT
ACCEPTABLE
FINISH NOTES
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. INSTALL CORNER GUARDS (CG-1) ON ALL OUTSIDE
CORNERS. INSTALL END WALL PROTECTORS AT OPEN
ENDED WALLS. CORNER GUARDS AND END CAPS MUST BE
FULL HEIGHT AND SHOULD NOT BE USED ON CMU WALLS,
TILED WALLS, OR MANUFACTURED STONE WALLS.
I. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST
INCLUDE METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE
CORNERS AS WELL AS THE INTERSECTION BETWEEN
FLOOR AND WALL TILE WHERE APPLICABLE FOR A
COMPLETE INSTALLATION.
J. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
K. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR
FRAMES TO BE PAINTED (PNT-5). ALL GWB & EXPOSED
CEILINGS TO BE PAINTED (PNT-6).
L. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
M. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
N. ALL TILE TO RECEIVE GROUT FINISH (GR-1).
O. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF
EACH SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY
INTO THE TOILET/SHOWER COMPARTMENT. SEE
ENLARGED PLAN VIEW B1/I-401.
P. SEE I-601 FOR FINISH LEGEND.
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
KITCHEN
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
MECHANICAL
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S3
S6
S8
S3
S6
S8
S1S6
S6S7 S7S7
S1
I-402 B1
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
VENDING
DUTY
CORRIDOR
LAUNDRY
S3
S8
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-111
APG
JDK
JDK REPAIR BEQ HP135
FIRST FLOOR SIGNAGE PLAN
60042872 N40085-25-B-0011
15 MAY 2026
SIGNAGE SCHEDULE
TYPE DESCRIPTION QTY
S1 SLEEPING QUARTERS IDENTIFICATION SIGN 90
S2 PERMANENT ROOM IDENTIFICATION SIGN 20
S3 STAIRWELL LEVEL INDICATOR 15
S5 UNISEX RESTROOM IDENTIFICATION SIGN 3
S6 SMALL DIRECTIONAL SIGN 20
S7 EXTERIOR ROOM SIGN 13
S8 STAIRWELL IDENTIFICATION SIGN 18
SIGNAGE NOTES
A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.
B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO
BE VERIFIED WITH END USER AND REVIEWED BY NAVFAC
INTERIOR DESIGNER PRIOR TO FABRICATION.
C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM
THE SURFACE WITH ROUNDED DOTS.
D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES.
CHARACTERS MUST BE UPPER CASE AND USE SANS SERIF
FONTS.
E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR
INDIVIDUALS WITH LOW VISION, BLINDNESS AND COGNITIVE
DISABILITIES.
F. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.
G. SEE ELEVATIONS B5/I-501 & C5/I-501 FOR MOUNTING HEIGHT
OF ACRYLIC SIGNAGE.
H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE
FINISHES.
I. MOUNTING OF SIGNAGE SYSTEM SHALL INCLUDE SURFACE
MOUNTING WITH SCREW-ON APPLICATION FOR INTERIOR
WALLS.
J. SIGNS THAT MOUNT TO GLASS SHALL INCLUDE AN EQUALLY
SIZED BLANK SIGN PANEL ALIGNED TO OPPOSITE SIDE OF
THE GLASS.
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"B1 1ST FLOOR SIGNAGE PLAN
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
STORAGE
COMM
CORRIDOR
LOUNGE
MECHANICAL
MECHANICAL
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S3
S6
S8
S3
S6
S8
S1
S3S7 S7S7
S1
I-402 B3
S3
S8
S6
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-112
APG
JDK
JDK REPAIR BEQ HP135
SECOND FLOOR SIGNAGE PLAN
60042873 N40085-25-B-0011
15 MAY 2026
SIGNAGE SCHEDULE
TYPE DESCRIPTION QTY
S1 SLEEPING QUARTERS IDENTIFICATION SIGN 90
S2 PERMANENT ROOM IDENTIFICATION SIGN 20
S3 STAIRWELL LEVEL INDICATOR 15
S5 UNISEX RESTROOM IDENTIFICATION SIGN 3
S6 SMALL DIRECTIONAL SIGN 20
S7 EXTERIOR ROOM SIGN 13
S8 STAIRWELL IDENTIFICATION SIGN 18
SIGNAGE NOTES
A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.
B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO
BE VERIFIED WITH END USER AND REVIEWED BY NAVFAC
INTERIOR DESIGNER PRIOR TO FABRICATION.
C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM
THE SURFACE WITH ROUNDED DOTS.
D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES.
CHARACTERS MUST BE UPPER CASE AND USE SANS SERIF
FONTS.
E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR
INDIVIDUALS WITH LOW VISION, BLINDNESS AND COGNITIVE
DISABILITIES.
F. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.
G. SEE ELEVATIONS B5/I-501 & C5/I-501 FOR MOUNTING HEIGHT
OF ACRYLIC SIGNAGE.
H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE
FINISHES.
I. MOUNTING OF SIGNAGE SYSTEM SHALL INCLUDE SURFACE
MOUNTING WITH SCREW-ON APPLICATION FOR INTERIOR
WALLS.
J. SIGNS THAT MOUNT TO GLASS SHALL INCLUDE AN EQUALLY
SIZED BLANK SIGN PANEL ALIGNED TO OPPOSITE SIDE OF
THE GLASS.
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"B1 2ND FLOOR SIGNAGE PLAN
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHCANIAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
MECHANICAL
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S3
S6
S8
S3
S6
S8
S1
S3S7 S7S7
S1
I-402 B5
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
STORAGE
OFFICE
CORRIDOR
LOUNGE
S3
S8
S6
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-113
APG
JDK
JDK REPAIR BEQ HP135
THIRD FLOOR SIGNAGE PLAN
60042874 N40085-25-B-0011
15 MAY 2026
SIGNAGE SCHEDULE
TYPE DESCRIPTION QTY
S1 SLEEPING QUARTERS IDENTIFICATION SIGN 90
S2 PERMANENT ROOM IDENTIFICATION SIGN 20
S3 STAIRWELL LEVEL INDICATOR 15
S5 UNISEX RESTROOM IDENTIFICATION SIGN 3
S6 SMALL DIRECTIONAL SIGN 20
S7 EXTERIOR ROOM SIGN 13
S8 STAIRWELL IDENTIFICATION SIGN 18
SIGNAGE NOTES
A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.
B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO
BE VERIFIED WITH END USER AND REVIEWED BY NAVFAC
INTERIOR DESIGNER PRIOR TO FABRICATION.
C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM
THE SURFACE WITH ROUNDED DOTS.
D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES.
CHARACTERS MUST BE UPPER CASE AND USE SANS SERIF
FONTS.
E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR
INDIVIDUALS WITH LOW VISION, BLINDNESS AND COGNITIVE
DISABILITIES.
F. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.
G. SEE ELEVATIONS B5/I-501 & C5/I-501 FOR MOUNTING HEIGHT
OF ACRYLIC SIGNAGE.
H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE
FINISHES.
I. MOUNTING OF SIGNAGE SYSTEM SHALL INCLUDE SURFACE
MOUNTING WITH SCREW-ON APPLICATION FOR INTERIOR
WALLS.
J. SIGNS THAT MOUNT TO GLASS SHALL INCLUDE AN EQUALLY
SIZED BLANK SIGN PANEL ALIGNED TO OPPOSITE SIDE OF
THE GLASS.
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"B1 3RD FLOOR SIGNAGE PLAN
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
SS-1
PLAM-1
CABINETS
RB-1
TOE KICK
GFGI MICRO-
FRIDGE UNIT
PNT-1
PLAM-1
CABINETS
12"
ANGLED
12" 15"
FIELD VERIFY
25" 14" 2" 24"
SCRIBE TO
CEILING
D4 I-301
A2 I-301
_______SS-1
PLAM-1
FILLER STRIPS
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
CFCI SINKS CENTERED
ON CASEWORK
SCRIBE TO
CEILING
PLAM-1
FILLER STRIP
MIRROR
24" 2" 28" 1" 1"30"1"
SS-1
1"26"12"15"
PNT-1
D3 I-301
D1 I-301
_______A1 I-301
1" 28" 2" 24" 1"
30" 1"
1" 26"
ANGLED
12" 15"
SS-1
PLAM-1
FILLER STRIPS
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
CFCI SINKS CENTERED
ON CASEWORK
SCRIBE TO
CEILING
PLAM-1
FILLER STRIP
PNT-1
D1 I-301
_______ A1 I-301
D3 I-301
24" 2" 14"
FIELD VERIFY
25"
15"
ANGLED
12" 12"
SS-1
PLAM-1
CABINETS
RB-1
TOE KICK
GFGI MICRO-
FRIDGE UNIT
PNT-1
PLAM-1
CABINETS
SCRIBE TO
CEILING
D4 I-301
A2 I-301
36" 12"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHEVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A4 I-301
18" 30"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHELVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A3 I-301
12" 36"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHELVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A4 I-301
30" 18"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHELVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A3 I-301
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-201
APG
JDK
JDK REPAIR BEQ HP135
INTERIOR ELEVATIONS
60042875 N40085-25-B-0011
15 MAY 2026
CASEWORK NOTES
1. CASEWORK CONSTRUCTION AS INDICATED IN THE
DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY
STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.
SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING
CUSTOM GRADE STANDARDS
2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS
SECTION 06 41 16.0 AND SECTION 06 61 1.
3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID
SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE
APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.
4. ALL BASE CABINETS, WALL CABINETS, APRONS AND
SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).
5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).
6. SEE SHEET I-601 FOR FINISH LEGEND.
SCALE: 3/4" = 1'-0"A2 TYP. KITCHENETTE
SCALE: 3/4" = 1'-0"A1 TYP. BATHROOM VANITY & KITCHENETTE
SCALE: 3/4" = 1'-0"C1 TYP. BATHROOM VANITY & KITCHENETTE
SCALE: 3/4" = 1'-0"C2 TYP. KITCHENETTE
SCALE: 3/4" = 1'-0"C3 TYP. CLOSET ROD
SCALE: 3/4" = 1'-0"C4 TYP. CLOSET CASEWORK
SCALE: 3/4" = 1'-0"A3 TYP. CLOSET ROD
SCALE: 3/4" = 1'-0"A4 TYP. CLOSET CASEWORK
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF
DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND
SALIENT CHARACTERISTICS ONLY. THE LISTING OF
MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT
THE SELECTION OF PRODUCTS PROVIDED BY OTHER
MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA
WILL BE CONSIDERED AND MUST BE REVIEWED BY THE
INTERIOR DESIGNER OF RECORD (IDOR) AND THE NAVFAC
INTERIOR DESIGNER AND APPROVED BY THE
CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO
AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY
LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN THE
CENTER OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM
CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL
COLOR. PANELS PAINTED BY BRUSH ARE NOT
ACCEPTABLE
FINISH NOTES
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. INSTALL CORNER GUARDS (CG-1) ON ALL OUTSIDE
CORNERS. INSTALL END WALL PROTECTORS AT OPEN
ENDED WALLS. CORNER GUARDS AND END CAPS MUST BE
FULL HEIGHT AND SHOULD NOT BE USED ON CMU WALLS,
TILED WALLS, OR MANUFACTURED STONE WALLS.
I. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST
INCLUDE METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE
CORNERS AS WELL AS THE INTERSECTION BETWEEN
FLOOR AND WALL TILE WHERE APPLICABLE FOR A
COMPLETE INSTALLATION.
J. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
K. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR
FRAMES TO BE PAINTED (PNT-5). ALL GWB & EXPOSED
CEILINGS TO BE PAINTED (PNT-6).
L. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
M. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
N. ALL TILE TO RECEIVE GROUT FINISH (GR-1).
O. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF
EACH SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY
INTO THE TOILET/SHOWER COMPARTMENT. SEE
ENLARGED PLAN VIEW B1/I-401.
P. SEE I-601 FOR FINISH LEGEND.
0' 1' 2' 3' 3/4" =1'-0"
GRAPHIC SCALE:
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
36" 36" 36" 4" 24"
36" 36" 36"
ANGLED
12" 15"
SS-1
PLAM-1
FILLER STRIP
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
CFCI SINK CENTERED
ON CASEWORK
PNT-1
CP-1
CABINET PULLS
GFGI ICE
MACHINE
D4 I-301
D3
I-301
D2 I-301
_______ A1 I-301
SS-1
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
PNT-1
CP-1
CABINET PULLS
GFGI
APPLIANCES
24" 4" 18" 18"
VERIFY W/ EQUIP.
30" 18" 18"
15"
ANGLED
12" 36"
VERIFY W/ EQUIP.
30" 36"
GFGI
APPLIANCE
A2 I-301
D4 I-301
D2 I-301
D3 I-301
SIM.
CFCI
APPLIANCE
C
O U
R
SE
S
C O
U R
SE
S
TO
C
EI
LI
N G
T-3
T-2
TS-5
T-2
B2 I-502
1/8" GROUT LINES
U P
TO
C
EI
LI
N G
FRP-1
RB-2C6
I-502
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-202
APG
JDK
JDK REPAIR BEQ HP135
INTERIOR ELEVATIONS
60042876 N40085-25-B-0011
15 MAY 2026
0' 1' 2' 3' 3/4" =1'-0"
GRAPHIC SCALE:
SCALE: 3/4" = 1'-0"C1 LOUNGE/COMMON KITCHEN
SCALE: 3/4" = 1'-0"C3 LOUNGE/COMMON KITCHEN
SCALE: 3/4" = 1'-0"A1 TYP. RESTROOM TILE ELEVATION
CASEWORK NOTES
1. CASEWORK CONSTRUCTION AS INDICATED IN THE
DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY
STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.
SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING
CUSTOM GRADE STANDARDS
2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS
SECTION 06 41 16.0 AND SECTION 06 61 1.
3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID
SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE
APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.
4. ALL BASE CABINETS, WALL CABINETS, APRONS AND
SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).
5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).
6. SEE SHEET I-601 FOR FINISH LEGEND.
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF
DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND
SALIENT CHARACTERISTICS ONLY. THE LISTING OF
MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT
THE SELECTION OF PRODUCTS PROVIDED BY OTHER
MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA
WILL BE CONSIDERED AND MUST BE REVIEWED BY THE
INTERIOR DESIGNER OF RECORD (IDOR) AND THE NAVFAC
INTERIOR DESIGNER AND APPROVED BY THE
CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO
AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY
LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN THE
CENTER OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM
CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL
COLOR. PANELS PAINTED BY BRUSH ARE NOT
ACCEPTABLE
FINISH NOTES
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. INSTALL CORNER GUARDS (CG-1) ON ALL OUTSIDE
CORNERS. INSTALL END WALL PROTECTORS AT OPEN
ENDED WALLS. CORNER GUARDS AND END CAPS MUST BE
FULL HEIGHT AND SHOULD NOT BE USED ON CMU WALLS,
TILED WALLS, OR MANUFACTURED STONE WALLS.
I. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST
INCLUDE METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE
CORNERS AS WELL AS THE INTERSECTION BETWEEN
FLOOR AND WALL TILE WHERE APPLICABLE FOR A
COMPLETE INSTALLATION.
J. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
K. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR
FRAMES TO BE PAINTED (PNT-5). ALL GWB & EXPOSED
CEILINGS TO BE PAINTED (PNT-6).
L. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
M. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
N. ALL TILE TO RECEIVE GROUT FINISH (GR-1).
O. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF
EACH SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY
INTO THE TOILET/SHOWER COMPARTMENT. SEE
ENLARGED PLAN VIEW B1/I-401.
P. SEE I-601 FOR FINISH LEGEND.
SCALE: 3/4" = 1'-0"A2 TYP.DRYER CHASE ELEVATION I
G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
SOLID SURFACE
COUNTERTOP WITH
EASED EDGE
HPL OVER 3/4"
PLYWOOD ON ALL
EXPOSED SURFACES
24"
HPL
INTERIOR
1/
2"
1/ 2"
4"
3" 21"
STAINLESS STEEL
BAR PULL
RUBBER BASE
AT TOE KICK
SOLID SURFACE
BACKSPLASH
WITH CLEAR SEALANT
APPLIED AT TRANSITION
24"
3/ 4"
4" 3/
4"
UNDERMOUNT STAINLESS
STEEL SINK
SOLID SURFACE
COUNTERTOP
1/4" DRAWER
BOTTOM - DADO INTO
DRAWER BACK &
FRONT
INTERIOR
DRAWER BOXES
FINISHED IN HPL
1/4" CABINET BACK
DRAWER FRONTS
FINISHED IN HPL
W/ MATCHING PVC
EDGEBAND
RUBBER BASE
AT TOE KICK
FULL EXTENSION
DRAWER SLIDES
3" 21"
24"
1/
2"
3/ 8"
3/
4"
1/ 8"
1/
2"
1/ 8"
1/
2"
1/ 8"
9" 4"
FULL HEIGHT SOLID
SURFACE BACKSPLASH
24"
HPL ADJUSTABLE
SHELVES W/ 1-1/4"
LINE BORE
3/4" X 1-1/2"
HARDWOOD NOSING.
STAIN
SECURE
CASEOWORK W/
MASONRY ANCHOR,
10" O.C.
12"
1/
2"
1/ 2"
1/
2"
1/ 2"
1/
2"
1/ 2"
1X6 PLYWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS
SPECIFIED
HPL FIXED SHELF W/ 3/4"
PLYWOOD SUBSTRATE
3/4" X 1-1/2"
HARDWOOD NOSING.
STAIN TO MATCH HPL.
6"
18"
1/
2"
15"
FULL OVERLAY
FLUSH DOOR
FINISHED IN HPL
W/ MATCHING PVC
EDGEBAND
1/4" CABINET BACK
HPL INTERIOR
15"
FULL OVERLAY
FLUSH DOOR
FINISHED IN HPL
W/ MATCHING PVC
EDGEBAND
1/4" CABINET BACK
3/4" HPL ADJUSTABLE
SHELF
HPL INTERIOR
RECESSED STANDARDS
SOLID SURFACE
COUNTERTOP WITH
EASED EDGE
HPL OVER 3/4"
PLYWOOD ON ALL
EXPOSED INTERIOR &
EXTERIOR SURFACES
24"
2" 6"
4"
3" 21"
STAINLESS STEEL
BAR PULLS
RUBBER BASE
AT TOE KICK
24"
1" 4"
1"
INTERIOR DRAWER
BOX FINISHED IN HPL
FULL EXTENSION
DRAWER SLIDES
FULL HEIGHT SOLID
SURFACE BACKSPLASH
3/4" HPL ADJUSTABLE
SHELF
RECESSED STANDARDS
HPL ON 3/4"
PLYWOOD
REMOVABLE PANEL
SOLID SURFACE
COUNTERTOP W/
WATER RESISTANT
SUBSTRATE
FALSE FRONT
4" INTEGRAL
BACKSPLASH (FULL
HEIGHT SPLASH AT
KITCHENETTE)
2" 1"
4" 1"
4"
INTEGRAL SOLID
SURFACE SINK
HPL
INTERIOR
RUBBER BASE
AT TOE KICK
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-301
APG
JDK
JDK REPAIR BEQ HP135
CASEWORK SECTIONS
60042877 N40085-25-B-0011
15 MAY 2026
CASEWORK NOTES
1. CASEWORK CONSTRUCTION AS INDICATED IN THE
DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY
STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.
SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING
CUSTOM GRADE STANDARDS
2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS
SECTION 06 41 16.0 AND SECTION 06 61 1.
3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID
SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE
APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.
4. ALL BASE CABINETS, WALL CABINETS, APRONS AND
SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).
5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).
6. SEE SHEET I-601 FOR FINISH LEGEND.
4"0' 1 1/2" =1'-0"
GRAPHIC SCALE:
8" 1'-4"
SCALE: 1 1/2" = 1'-0"A1 SECTION - SINK CABINET
SCALE: 1 1/2" = 1'-0"A2 SECTION - 4 DRAWER BASE CAB.
SCALE: 1 1/2" = 1'-0"A3 SECTION - CLOSET SHELVING
SCALE: 1 1/2" = 1'-0"A4 SECTION - CLOSET HANGING ROD
SCALE: 1 1/2" = 1'-0"D3 SECTION - UPPER CABINET 18"H
SCALE: 1 1/2" = 1'-0"D4 SECTION - UPPER CABINET 30"H
SCALE: 1 1/2" = 1'-0"D2 SECTION - DOOR/DRAWER BASE CAB.
SCALE: 1 1/2" = 1'-0"D1 SECTION - RESTROOM SINK CABINET
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
T-1
RES-1
SC-1
RES-2
T-4
SLEEPING
ROOM
SLEEPING
ROOM
I-201
A1
I-201
C1
A2 C2
I-201C3 I-201 A3
C4 A4
I-201
C4
C3 I-201
A4
A3
PN
T-
PN
T-
KITCHEN
I-202
C1
C3
PNT-2
LOUNGE
WG-1
WG-1
MECHANICAL
BUILDING
I-202A2 A2
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0011
CHRIS MAAS
W :\2
H P1
B
EQ
R en ov at io n C
L\ R ev it\
B C
ID
3-
H P1
.rv t 5/
/2
6:
:4
PM
I-401
APG
JDK
JDK REPAIR BEQ HP135
ENLARGED FINISH PLANS
60042878 N40085-25-B-0011
15 MAY 2026
0' 2' 4' 6' 3/8" =1'-0"
GRAPHIC SCALE:
SCALE: 3/8" = 1'-0"B1 ENLARGED SLEEPING ROOMS FINISH PLAN
SCALE: 3/8" = 1'-0"B3 ENLARGED KITCHEN FLOOR FINISH PLAN
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF
DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND
SALIENT CHARACTERISTICS ONLY. THE LISTING OF
MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT
THE SELECTION OF PRODUCTS PROVIDED BY OTHER
MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA
WILL BE CONSIDERED AND MUST BE REVIEWED BY THE
INTERIOR DESIGNER OF RECORD (IDOR) AND THE NAVFAC
INTERIOR DESIGNER AND APPROVED BY THE
CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO
AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY
LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN THE
CENTER OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM
CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL
COLOR. PANELS PAINTED BY BRUSH ARE NOT
ACCEPTABLE
FINISH NOTES
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. INSTALL CORNER GUARDS (CG-1) ON ALL OUTSIDE
CORNERS. INSTALL END WALL PROTECTORS AT OPEN
ENDED WALLS. CORNER GUARDS AND END CAPS MUST BE
FULL HEIGHT AND SHOULD NOT BE USED ON CMU WALLS,
TILED WALLS, OR MANUFACTURED STONE WALLS.
I. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST
INCLUDE METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE
CORNERS AS WELL AS THE INTERSECTION BETWEEN
FLOOR AND WALL TILE WHERE APPLICABLE FOR A
COMPLETE INSTALLATION.
J. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
K. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR
FRAMES TO BE PAINTED (PNT-5). ALL GWB & EXPOSED
CEILINGS TO BE PAINTED (PNT-6).
L. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
M. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
N. ALL TILE TO RECEIVE GROUT FINISH (GR-1).
O. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF
EACH SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY
INTO THE TOILET/SHOWER COMPARTMENT. SEE
ENLARGED PLAN VIEW B1/I-401.
P. SEE I-601 FOR FINISH LEGEND.
SCALE: 1/4" = 1'-0"B5 TYP. LOUNGE FINISH PLAN
2' 4' 8'0' 1/4" =1'-0"
SCALE: 1/4" = 1'-0"D3 ENLARGED MECHANICAL BLDG. FINISH PLAN
SCALE: 1/4" = 1'-0"B6 ENLARGED LAUNDRY CHASE FINISH PLAN
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
VENDING
DUTY
CORRIDOR
LAUNDRY
S7 S8S6
S3
S2
S2
S2
S2
S2
S5
S6
S2
S8
MECH
240 STAIR
LAUNDRY
TOILET
ELECTRICAL
STORAGE
COMM
CORRIDOR
LOUNGE
S7 S8S6
S3
S2
S2 S2
S2
S2
S5
S2
S6
S2
S8
MECH
STAIR
LAUNDRY
TOILET
ELECTRICAL
STORAGE
OFFICE
CORRIDOR
LOUNGE
S7 S8S6
S3
S2
S2
S2 S2
S2
S2
S5
S2
S6
S8
MECHANICAL
BUILDING
S7
2' 4' 8'0' 1/4" =1'-0"
GRAPHIC SCALE:
SCALE: 1/4" = 1'-0"B1 ENLARGED 1ST FLOOR SIGNAGE PLAN
SCAL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .