2024-118_-_Combined_Plumbing_-_S&S.pdf
PDF 7 MB Posted
- Attached to
- Michigan Avenue Warehouse Renovation
- Solicitation number
- ITB 25-098
- Issued by
- Lee County, Fruitville CDP, Florida
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CD
CD
SS
SS
ST
ST
V
V
HWR
HWR
HW
HW
CW
CW
CONDENSATE DRAIN
SANITARY SEWER/SOIL
STORM PIPING
VENT
DOMESTIC HOT WATER
RETURN
DOMESTIC HOT WATER
DOMESTIC COLD
WATER
SYMBOL DESCRIPTION
FLOOR CLEANOUT (FCO) /
EXTERIOR CLEANOUT (ECO)
FLOOR DRAIN (FD)
CHECK VALVE
BALL VALVE
HOSE BIBB
BALANCING VALVE
GATE VALVE
GLOBE VALVE
SANITARY TEE
WATER HAMMER
ARRESTOR (PDI)
WALL HYDRANT
SHEET WHERE SECTION APPEARS
SECTION DESIGNATION
P101
PIPE UP
PIPE DOWN
PIPE CAP
PIPE CONTINUATION
SECTION CALLOUT
G
G
GR
GR
NATURAL/PROPANE
GAS
GREASE
PLUMBING LEGEND
CA
CA
COMPRESSED AIR
SHEET WHERE RISER APPEARS
RISER DESIGNATION
P101
P501
FLOOR PLAN SHEET REFERENCE
RISER BUBBLE/CALLOUT
1. PLUMBING SYSTEM WAS DESIGNED USING THE 8TH EDITION, 2023
FBC.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
NECESSARY FITTINGS AS REQUIRED BY ALL APPLICABLE CODES
AND GOVERNING AUTHORITIES.
3. CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO
MEET ALL CODES AND REGULATIONS ANY POSSIBLE
DISCREPANCIES BETWEEN TYPE AND SIZE OF CONNECTION
SPECIFIED IN PLUMBING FIXTURE SCHEDULE AND FIXTURES
ACTUALLY INSTALLED ON THE SITE.
4. ALL SANITARY PIPING LARGER THAN 2 1/2" SHALL HAVE 1/8"
MINIMUM PER FOOT SLOPE. ALL SANITARY PIPING 2 1/2" AND
SMALLER SHALL HAVE A 1/4" MINIMUM PER FOOT SLOPE.
5. VENT PIPING SHOWN ON FLOOR PLANS IS ONLY INDICATIVE
EXCEPT FOR VTR LOCATIONS.
6. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER
TRADES.
7. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS
PRIOR TO LAYING AND CONNECTING ALL SANITARY AND WASTE
PIPING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES.
8. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER
ARRESTORS AS SPECIFIED.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE
RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING,
BOXES AND PENETRATIONS.
10. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS
CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN SIZES.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES INCLUDED
IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE.
12. ALL SANITARY AND WATER SUPPLY LINES SHALL BE MARKED
WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION
FOUNDATION.
13. WHERE SANITARY SEWER LINES CROSS UNDERGROUND WATER
SUPPLY LINES WITH LESS THAN 12" MINIMUM VERTICAL
CLEARANCE, THE SANITARY SEWER SHALL BE CONSTRUCTED OF
DUCTILE IRON PIPE (5' EACH SIDE OF WATER MAIN) OR THE
WATER LINES SHOULD BE MODIFIED TO PROVIDE 12" MINIMUM
CLEARANCE.
14. FLOOR DRAINS SHALL BE PROVIDED WITH TRAP GUARDS.
15. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS,
OR IN CHASES EXCEPT AS SPECIFICALLY NOTED, OR IN
MECHANICAL ROOMS.
16. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR
ABOVE NON-ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL
DRAWINGS FOR CEILING TYPES.
17. METERING AND SITE UTILITY CONNECTIONS SHALL BE PROVIDED
ON CIVIL DRAWINGS. ALL SERVICES SHOWN ON THIS SET OF
PLANS TERMINATE 5'-0" FROM BUILDING, UNLESS SHOWN
OTHERWISE ON DRAWINGS. PLUMBING CONTRACTOR SHALL
MAKE FINAL CONNECTIONS TO SITE UTILITIES.
18. FURNISH AND INSTALL HOSE BIBBS AND/OR WALL HYDRANTS 24"
ABOVE FINISHED GRADE/FLOOR AND PROVIDE VACUUM
BREAKERS.
19. SEE ARCHITECTURAL DRAWINGS FOR EXACT PLUMBING FIXTURE
LOCATIONS, MOUNTING HEIGHTS AND DIMENSIONS.
20. PIPING MAY BE SHOWN OFFSET FOR THE CLARITY OF PIPING
TYPE AND EQUIPMENT.
21. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO
WHICH NEW SEWER LINES ARE TO BE CONNECTED BEFORE
INSTALLATION OF NEW SEWER LINE.
22. ALL VENTS THROUGH ROOF SHALL BE MINIMUM 10'-0" FROM ANY
AIR INTAKES.
23. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT
CONNECTIONS OF DISSIMILAR METALS.
24. CONTRACTOR SHALL ROUGH-IN ALL WASTES AND SUPPLIES TO
SPECIAL EQUIPMENT ACCORDING TO MANUFACTURERS SHOP
DRAWINGS AND MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL
BE VALVED. INSTALL VACUUM BREAKERS WHERE REQUIRED BY
CODE.
25. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTERS FOR
DOMESTIC WATER SUPPLIES AS REQUIRED BY LOCAL WATER
PURVEYORS.
26. PROVIDE 1/2" C.W. AND H.W. SUPPLYS WITH ANGLE STOP AND
FLEXIBLE SUPPLY TO SINKS AS SPECIFIED AT HEIGHT REQUIRED
BY MANUFACTURER OF EQUIPMENT INSTALLED.
27. PROVIDE 1/2" C.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE
SUPPLY TO REFRIGERATORS WITH ICE MAKERS AT HEIGHT
REQUIRED BY MANUFACTURER OF EQUIPMENT INSTALLED.
28. PROVIDE 1/2" H.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE
SUPPLY TO DISHWASHER MACHINE, AT HEIGHT REQUIRED BY
MANUFACTURER OF EQUIPMENT INSTALLED.
29. ALL WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE
PLACED ON THE INTERIOR SIDE OF THE WALL, SO THAT WALL
INSULATION CAN BE PLACED ON THE EXTERIOR SIDE OF THE
PIPING.
30. COORDINATE EXACT LOCATION OF FLOOR AND HUB DRAINS FOR
HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR. PROVIDE A
HOSE BIBB WITHIN ALL MECHANICAL ROOMS.
31. THE CONTRACTOR IS EXPECTED TO ORDER ALL MATERIALS IN
SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE
PROJECT. DELAY IN DELIVERIES WILL NOT BE CONSIDERED A
JUSTIFIABLE REASON FOR SUBMISSION OF SUBSTITUTE
MATERIALS.
32. DO NOT PENETRATE WALL FOOTINGS WITH PIPING, COORDINATE
WITH GENERAL CONTRACTOR TO DROP OR BRIDGE FOOTINGS AS
REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY
NECESSARY. ALL PIPING PENETRATING A BEARING WALL OR
FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY
STRUCTURAL ENGINEER.
33. VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE
BUILDING AND SITE AFFECTED BY THIS WORK BEFORE
SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH
EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT
EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE
CONSTRUED, AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN
MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS
REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT
BE RECOGNIZED.
34. UNFORESEEN CONDITIONS MAY EXIST AND WORK MAY NOT BE
FIELD LOCATED EXACTLY AS SHOWN ON THE DRAWINGS.
COOPERATION WITH OTHER TRADES IN ROUTING AND/OR BURIAL
DEPTHS AS DETERMINED DURING CONSTRUCTION AND AS
DIRECTED BY THE ARCHITECT/ENGINEER MAY BE NECESSARY. IT
IS INTENDED THAT SUCH DEVIATIONS SHALL BE CONSIDERED AS
PART OF THIS CONTRACT. SUCH DEVIATIONS MAY NOT BE
CONSIDERED AS PART OF THIS CONTRACT WHEN PROPERLY
DOCUMENTED IN WRITING. THE PLANS ARE NOT COMPLETELY TO
SCALE. THIS CONTRACTOR IS TO FIELD VERIFY DIMENSIONS OF
ALL SITE UTILITIES, ETC., PRIOR TO BID AND INCLUDE ANY
DEVIATIONS IN THE CONTRACT.
35. ALL POINT OF USE MIXING VALVE (MV-1 AND MV-2) SHALL BE
LOCATED ABOVE AN ACCESSIBLE CEILING OR PROVIDED WITH AN
ACCESS PANEL UNLESS OTHERWISE NOTED.
36. INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE
OR BATTERY OF FIXTURES WHERE REQUIRED. ARRESTORS SHALL
BE FACTORY FABRICATED. INSTALL ARRESTORS AND SIZE PER
PLUMBING AND DRAINAGE INSTITUTE STANDARD PDI WH 201.
ACCEPTABLE MANUFACTURERS ZURN, JOSAM, JAY R. SMITH.
PDI UNITS
FIXTURE UNITS
A
1-11
B
12-32
C
33-60
D
61-113
E
114-154
F
155-330
WATER HAMMER ARRESTOR SIZING AND SELECTION TABLE
GENERAL NOTES - PLUMBING
- SHEET INDEX - PLUMBING -
Sheet Number Sheet Name
P001 GENERAL NOTES, LEGEND, ABBREVIATIONS & SHEET INDEX
P101-N GRAVITY - 1ST AND 2ND FLOOR PLANS - NORTH BUILDING
P101-S GRAVITY - 1ST FLOOR PLAN - SOUTH BUILDING
P101-S-2 GRAVITY - 1ST FLOOR PLAN - SOUTH BUILDING - ALTERNATE
P111-N PRESSURE - 1ST AND 2ND FLOOR PLANS - NORTH BUILDING
P111-S PRESSURE - 1ST FLOOR PLAN - SOUTH BUILDING
P111-S-2 PRESSURE - 1ST FLOOR PLAN - SOUTH BUILDING - ALTERNATE
P601 PLUMBING SCHEDULES
P602-2 PLUMBING SCHEDULES - ALTERNATE
P901 PLUMBING DETAILS
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:0
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P001
GENERAL NOTES, LEGEND,
ABBREVIATIONS & SHEET
INDEX
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
NO. DESCRIPTION DATE
DN
UP
DN
DN
DN
G R
A T
E
.4
4" SS
FD-1
WC-2
L-2
MS-1
FD-2
3" SS
RECORDS STORAGE
STAGING AREA
UNISEX R.R.
CUSTODIAL
FORKLIFT CHARGING
STATION
OFFICES/ MULTI-USE
PRINT ROOM
2" CD
4" SS
BWV-1
3 AAV-1
2" S
S
2" SS
2" SS
HD-1
HD-1
FD-2
HD-1
S S
C D
C D
IDF & MECH. ROOM
GENERAL NOTES:
1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE.
2) REFER TO SPECIFICATIONS.
3) PIPING MAY BE SHOWN OFFSET FOR CLARITY OF FIXTURES,
EQUIPMENT AND PIPE ROUTING TO CLARIFY INTENT OF DIFFERENT
PIPING SYSTEMS.
4) PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING WITH
ALL DISCIPLINES.
5) CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS
PRIOR TO INSTALLATION OF PIPING.
6) SAME PIPING, FIXTURES AND EQUIPMENT MAY SHOWN ON MORE
THAN ONE SHEET TO CLARIFY CONNECTION AND ROUTING OF PIPE
ACROSS MATCH LINE.
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
HEX NOTES:
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:3
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P101-N
GRAVITY - 1ST AND 2ND
FLOOR PLANS - NORTH
BUILDING
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1/4" = 1'-0"1 FIRST FLOOR NORTH BUILDING
1/4" = 1'-0"2 SECOND FLOOR NORTH BUILDING
1 SANITARY BELOW GRADE, FOR CONTINUATION, REFER TO CIVIL
PLANS. INVERT ELEVATION -2'-0" B.F.F.
2 VENT TO VTR.
3 ROUTE PIPING UP TO ACCESSIBLE CEILING SPACE AND PROVIDE
AIR ADMITTANCE VALVE (AA-1)
4 PROVIDE BACKWATER VALVE (BWV-1) WITHIN VALVE BOX, SEE
DETAIL.
5 CONNECT CONDENSATE PIPING TO STORM PIPING
DOWN-STREAM OF EXTENAL RAIN LEADER.
DN
S
T O
B
BFP
FD-2
EW-1
WC-2
L-2
L-2
SH-1
EWC-1
L-2L-2
L-2
L-2
L-2
L-2
WC-1
WC-2
WC-2
U-1
S-1
FCO
FD-1
FD-2
FCO
FD-1
FD-1
3" S
S
3" SS
S S
S S
4" SS
S S
4" SS
4" SS 4" SS1
BWV-1
4" SS
HD-1 3" CD
AAV-13
CUSTODIAL
SMALL CONFERENCE
ROOM
OFF. SUPPLIES
CUBICLE 1
CUBICLE 2
MAINTENANCE &
REPAIRS AREA
EQUIPMENT TOOL'S
CAGES
MECH. ROOM
ELECTRICAL ROOM
MDF ROOM
CLOSET
LARGE CONFERENCE
ROOM
EXECUTIVE OFFICE
CUBICLE 5
CUBICLE 4
SENIOR ASSIST.
PUBLIC
MEN'S RESTROOM
WOMEN'S RESTROOM
LOUNGE ROOM
SPECIAL EVENTS
STORAGE/ MULTI-USE
WORK ROOM
CUBICLE 3
CUBICLE 8
CUBICLE 9
CUBICLE 7
CUBICLE 12
CUBICLE 11
CUBICLE 10
CUBICLE 13
CUBICLE 6
OPEN SPACE
PARKS & REC
WAREHOUSE
FD-2FD-1
WC-2
EWC-1
GENERAL NOTES:
1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE.
2) REFER TO SPECIFICATIONS.
3) PIPING MAY BE SHOWN OFFSET FOR CLARITY OF FIXTURES,
EQUIPMENT AND PIPE ROUTING TO CLARIFY INTENT OF DIFFERENT
PIPING SYSTEMS.
4) PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING WITH
ALL DISCIPLINES.
5) CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS
PRIOR TO INSTALLATION OF PIPING.
6) SAME PIPING, FIXTURES AND EQUIPMENT MAY SHOWN ON MORE
THAN ONE SHEET TO CLARIFY CONNECTION AND ROUTING OF PIPE
ACROSS MATCH LINE.
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
HEX NOTES:
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:3
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P101-S
GRAVITY - 1ST FLOOR
PLAN - SOUTH BUILDING
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1/4" = 1'-0"1 FIRST FLOOR SOUTH BUILDING
1 SANITARY BELOW GRADE, FOR CONTINUATION, REFER TO CIVIL
PLANS. INVERT ELEVATION -2'-0" B.F.F.
2 VENT TO VTR.
3 ROUTE PIPING UP TO ACCESSIBLE CEILING SPACE AND PROVIDE
AIR ADMITTANCE VALVE (AAV-1)
4 PROVIDE BACKWATER VALVE (BWV-1) WITHIN VALVE BOX, SEE
DETAIL.
5 CONNECT CONDENSATE PIPING TO STORM PIPING
DOWN-STREAM OF EXTERNAL RAIN LEADER.
DN
DN
S
T O
B
BFP
FD-2
EW-1
WC-1
WC-1WC-2
WC-2
L-1L-1
L-1L-1
L-2
L-2SH-1
SH-1
EWC-1
EWC-1
MS-1
U-1
L-2L-2
L-2
L-2
L-2
L-2
WC-1
WC-2
WC-2
U-1
S-1
FD-2
FCO
FD-2
FD-1
FD-1
FD-2
FCO
FD-1
FD-1
U-1 U-1
3" S
S
3" SS
S S
S S
4" SS
S S
4" SS
4" SS
3" S
S
4" SS
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
SMALL CONFERENCE
ROOM
LOUNGE ROOM
LARGE CONFERENCE
ROOM
SPECIAL EVENT
STORAGE/ MULTI-USE
WORK ROOM
MEN'S RESTROOM
CUSTODIAL
PUBLIC
WOMEN'S RESTROOM
CUBICLE 6
WOMEN'S BATHROOM
MEN'S BATHROOM
OFFICE 6
MDF ROOM
OPEN SPACE
EQUIPMENT TOOLS
CAGES
OFF. SUPPLIES
CUBICLE 4
CUBICLE 5
MAINTENANCE &
REPAIRS AREA
CUSTODIAL
MECH. ROOM
ELECTRIAL ROOM
PARKS & REC
WAREHOUSE
CLOSET
EXECUTIVE OFFICE
CUBICLE 3
CUBICLE 2
SENIOR ASSIST.
OFFICE 1
OFFICE 2
CUSTODIAL
BWV-1
4" SS
HD-1 3" CD
V
1 1/2" V
V
S S
AAV-13
GENERAL NOTES:
1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE.
2) REFER TO SPECIFICATIONS.
3) PIPING MAY BE SHOWN OFFSET FOR CLARITY OF FIXTURES,
EQUIPMENT AND PIPE ROUTING TO CLARIFY INTENT OF DIFFERENT
PIPING SYSTEMS.
4) PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING WITH
ALL DISCIPLINES.
5) CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS
PRIOR TO INSTALLATION OF PIPING.
6) SAME PIPING, FIXTURES AND EQUIPMENT MAY SHOWN ON MORE
THAN ONE SHEET TO CLARIFY CONNECTION AND ROUTING OF PIPE
ACROSS MATCH LINE.
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
HEX NOTES:
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:1
:5
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_ O p ti o n
T w o
R e v it
B
IM
.r v t
P101-S-2
GRAVITY - 1ST FLOOR
PLAN - SOUTH BUILDING -
ALTERNATE
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1/4" = 1'-0"1 FIRST FLOOR SOUTH BUILDING
1 SANITARY BELOW GRADE, FOR CONTINUATION, REFER TO CIVIL
PLANS. INVERT ELEVATION -2'-0" B.F.F.
2 VENT TO VTR.
3 ROUTE PIPING UP TO ACCESSIBLE CEILING SPACE AND PROVIDE
AIR ADMITTANCE VALVE (AAV-1)
4 PROVIDE BACKWATER VALVE (BWV-1) WITHIN VALVE BOX, SEE
DETAIL.
5 CONNECT CONDENSATE PIPING TO STORM PIPING
DOWN-STREAM OF EXTERNAL RAIN LEADER.
UP
DN
DN
DN
G R
A T
E
.4
EWH-N-1
HB-1 HB-1
HB-1
HB-1
L-2
WC-2
MS-1
3/4" CW
3/4" CW3/4" CW
C W
C W
1" CW
MV-1
/4
C
W
C W
4 4
RECORDS STORAGE
STAGING AREA
UNISEX R.R.
CUSTODIAL
OFFICES/ MULTI-USE
PRINT ROOM
/4
C
W
3/4" CW
3/4" CW
HB-2
IDF & MECH. ROOM
GENERAL NOTES:
1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE.
2) REFER TO SPECIFICATIONS.
3) PIPING MAY BE SHOWN OFFSET FOR CLARITY OF FIXTURES,
EQUIPMENT AND PIPE ROUTING TO CLARIFY INTENT OF DIFFERENT
PIPING SYSTEMS.
4) PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING WITH
ALL DISCIPLINES.
5) CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS
PRIOR TO INSTALLATION OF PIPING.
6) SAME PIPING, FIXTURES AND EQUIPMENT MAY SHOWN ON MORE
THAN ONE SHEET TO CLARIFY CONNECTION AND ROUTING OF PIPE
ACROSS MATCH LINE.
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
HEX NOTES:
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:1
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P111-N
PRESSURE - 1ST AND 2ND
FLOOR PLANS - NORTH
BUILDING
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1/4" = 1'-0"1 FIRST FLOOR NORTH BUILDING
1/4" = 1'-0"2 SECOND FLOOR NORTH BUILDING
1 DOMESTIC WATER BELOW GRADE, FOR CONTINUATION, REFER TO
CIVIL PLANS. INVERT ELEVATION -2'-0".
2 PROVIDE BUILDLING SHUT-OFF VALVE 36” ABOVE SLAB.
3 PROVIDE WATER HEATER ON SHELF AS SCHEDULED.
4 PROVIDE HOSE BIBB (HB-1) AT 6” ABOVE SLAB.
5 3/4”CW ROUTED TO ABOVE MECHANICAL MEZZANINE. REFER TO
SECOND FLOOR PLAN.
6 COLD WATER PIPING UP FROM 1ST FLOOR.
7 COLD WATER PIPING DOWN TO 1ST FLOOR.
8 3/4”CW ROUTED TO DOWN FROM MECHANICAL MEZZANINE.
DN
S
T O
B
BFP
EW-1
WC-2
EWC-1
L-2L-2
L-2
L-2
L-2L-2
WC-1
WC-2
WC-2
U-1
S-1
1 1/4" CW
EWH-S-1
CP-S-2
MS-1
MV-2
MV-1
BV-1
HB-2
HB-1
HB-1
/4
C W
/4
C W
/4
H
W
1/2" CW
3/4" HWR
/4
H
W
/2
C
W
/4
C
W
3/4" CW
1 1/4" CW
1/2" CW
3/4" CW
IMB-1
3/4" HWR
/4
H
W R
/4
H
W
MV-2
BV-1
CUSTODIAL
SMALL CONFERENCE
ROOM
OFF. SUPPLIES
CUBICLE 1
CUBICLE 2
MAINTENANCE &
REPAIRS AREA
EQUIPMENT TOOL'S
CAGES
MECH. ROOM
ELECTRICAL ROOM
MDF ROOM
CLOSET
LARGE CONFERENCE
ROOM
EXECUTIVE OFFICE
CUBICLE 5
CUBICLE 4
SENIOR ASSIST.
PUBLIC
MEN'S RESTROOM
WOMEN'S RESTROOM
LOUNGE ROOM
SPECIAL EVENTS
STORAGE/ MULTI-USE
WORK ROOM
CUBICLE 3
CUBICLE 8
CUBICLE 9
CUBICLE 7
CUBICLE 12
CUBICLE 11
CUBICLE 10
CUBICLE 13
CUBICLE 6
OPEN SPACE
PARKS & REC
WAREHOUSE
WC-2
L-2 L-2
SH-1
HB-1 HB-1
BV-1
/4
H
W R
H W
/4
C W
1" CW 1" CW
/4
C
W
C W
1" HW
3/4" HWR
/4
C
W
/2
C
W
GENERAL NOTES:
1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE.
2) REFER TO SPECIFICATIONS.
3) PIPING MAY BE SHOWN OFFSET FOR CLARITY OF FIXTURES,
EQUIPMENT AND PIPE ROUTING TO CLARIFY INTENT OF DIFFERENT
PIPING SYSTEMS.
4) PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING WITH
ALL DISCIPLINES.
5) CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS
PRIOR TO INSTALLATION OF PIPING.
6) SAME PIPING, FIXTURES AND EQUIPMENT MAY SHOWN ON MORE
THAN ONE SHEET TO CLARIFY CONNECTION AND ROUTING OF PIPE
ACROSS MATCH LINE.
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
HEX NOTES:
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:4
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P111-S
PRESSURE - 1ST FLOOR
PLAN - SOUTH BUILDING
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1/4" = 1'-0"1 FIRST FLOOR SOUTH BUILDING
1 DOMESTIC WATER BELOW GRADE, FOR CONTINUATION, REFER TO
CIVIL PLANS. INVERT ELEVATION -2'-0".
DN
DN
S
T O
B
BFP
EW-1WC-1
WC-1
WC-2
WC-2
L-1L-1
L-1L-1
L-2
L-2
SH-1
SH-1
EWC-1
EWC-1
MS-1
U-1
L-2L-2
L-2
L-2
L-2L-2
WC-1
WC-2
WC-2
U-1
S-1
U-1U-1
1 1/4" CW
EWH-S-2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
SMALL CONFERENCE
ROOM
LOUNGE ROOM
LARGE CONFERENCE
ROOM
SPECIAL EVENT
STORAGE/ MULTI-USE
WORK ROOM
MEN'S RESTROOM
CUSTODIAL
PUBLIC
WOMEN'S RESTROOM
CUBICLE 6
WOMEN'S BATHROOM
MEN'S BATHROOM
OFFICE 6
MDF ROOM
OPEN SPACE
EQUIPMENT TOOLS
CAGES
OFF. SUPPLIES
CUBICLE 4
CUBICLE 5
MAINTENANCE &
REPAIRS AREA
MECH. ROOM
ELECTRIAL ROOM
PARKS & REC
WAREHOUSE
CLOSET
EXECUTIVE OFFICE
CUBICLE 3
CUBICLE 2
SENIOR ASSIST.
OFFICE 1
OFFICE 2
CUSTODIAL
CP-S-2
MS-1
MV-2
MV-1
BV-1
HB-2
HB-1
HB-1
/4
C W
/4
C W
/4
H
W
1/2" CW
3/4" HWR
/4
H
W
/2
C
W
/4
C
W
3/4" CW
1 1/4" CW
C W
/4
H
W
C W
C W
1/2" CW
HB-1
HB-1
/4
C
W
/4
C
W
3/4" CW
IMB-1
3/4" HWR
/4
H
W R
/4
H
W
MV-2
BV-1
CUSTODIAL
/4
H
W R
/4
H
W
C W
1" HW
H W
/4
H
W R
MV-3
EWH-S-1
GENERAL NOTES:
1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE.
2) REFER TO SPECIFICATIONS.
3) PIPING MAY BE SHOWN OFFSET FOR CLARITY OF FIXTURES,
EQUIPMENT AND PIPE ROUTING TO CLARIFY INTENT OF DIFFERENT
PIPING SYSTEMS.
4) PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING WITH
ALL DISCIPLINES.
5) CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS
PRIOR TO INSTALLATION OF PIPING.
6) SAME PIPING, FIXTURES AND EQUIPMENT MAY SHOWN ON MORE
THAN ONE SHEET TO CLARIFY CONNECTION AND ROUTING OF PIPE
ACROSS MATCH LINE.
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
HEX NOTES:
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:1
:5
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_ O p ti o n
T w o
R e v it
B
IM
.r v t
P111-S-2
PRESSURE - 1ST FLOOR
PLAN - SOUTH BUILDING -
ALTERNATE
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1/4" = 1'-0"1 FIRST FLOOR SOUTH BUILDING
1 DOMESTIC WATER BELOW GRADE, FOR CONTINUATION, REFER TO
CIVIL PLANS. INVERT ELEVATION -2'-0".
FIXTURE UNITS 1-11 12-32 33-60 61-113 114-154 155-330
PDI UNITS A B C D E F
WATER HAMMER ARRESTOR SIZING AND SELECTION TABLE
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:2
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P501
PLUMBING RISER
DIAGRAMS
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
2 FIRST FLOOR NORTH BUILDING - GRAVITY RISER DIAGRAM
FIRST FLOOR NORTH BUILDING - PRESSURE RISER
DIAGRAM Copy 1
FIXTURE UNITS 1-11 12-32 33-60 61-113 114-154 155-330
PDI UNITS A B C D E F
WATER HAMMER ARRESTOR SIZING AND SELECTION TABLE
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:1
:5
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_ O p ti o n
T w o
R e v it
B
IM
.r v t
P501-2
PLUMBING RISER
DIAGRAMS - ALTERNATE
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
2 FIRST FLOOR NORTH BUILDING - GRAVITY RISER DIAGRAM
FIRST FLOOR NORTH BUILDING - PRESSURE RISER
DIAGRAM Copy 1
MS-1
EWH-S-1
MV-2
CP-S-2
MV-1
BV-1
HB-2
HB-1
HB-1
EW-1
WC-2
WC-2
L-2
L-2
SH-1
EWC-1
L-2
L-2
L-2
L-2
L-2
L-2
WC-1
WC-2
WC-2
U-1
S-1
1 1/4" C W
1 1/4" CW
/4
C W
1/2" CW
/2
C
W
1/2" HW
1 1/4" C W
3/4" H W
MV-2
MV-2
1/2" C W
3/4" C W
IMB-1
EW-1
WC-2
WC-2
L-2
L-2
SH-1
EWC-1
MS-1
L-2
L-2
L-2
L-2
L-2
L-2
WC-1
WC-2 WC-2
U-1
S-1
FD-2
3" SS
3" S S
FD-1
FCO
V
V
V
VTR
4" SS
2" V
2" V
/2
V
AAV-1
MS-1
3/4" CW
3/4" HW
CP-S-2
L-2
MV-2
3/4" H W
3/4" HW
R
3/4" H W
R
1" H W
1" H W
3/4" H W
R
/2
C
W
1 1/4" C W
/2
C
W
/2
C
W
3/4" HW
R
TET
EWH-S-1
/2
C
W
/4
H
W1/2" CW
3/4" H W
1/2" C W
3/4" C W
FIXTURE UNITS 1-11 12-32 33-60 61-113 114-154 155-330
PDI UNITS A B C D E F
WATER HAMMER ARRESTOR SIZING AND SELECTION TABLE
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:3
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P502
PLUMBING RISER
DIAGRAMS
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1 FIRST FLOOR SOUTH BUILDING - PRESSURE RISER DIAGRAM
2 FIRST FLOOR SOUTH BUILDING - GRAVITY RISER DIAGRAM
3 ENLARGED WATER HEATER PLAN
MV-3
MS-1
EWH-S-2
MV-2
EWH-S-1
CP-S-2
MV-1
BV-1
HB-2
HB-1
HB-1
HB-1
HB-1
EW-1
WC-1
WC-1
WC-2
WC-2
L-1
L-1
L-1
L-1
L-2
L-2
SH-1
SH-1
EWC-1
EWC-1
MS-1
U-1
L-2
L-2
L-2
L-2
L-2
L-2
WC-1
WC-2
WC-2
U-1
S-1
U-1
U-1
1 1/4" C W
1 1/4" CW
/2
C
W1 /2
C
W /4
H
W
HB-1
3/4" H W
3/4" C W
3/4" C W
1" C W
3/4" CW
/2
C
W
/2
C
W
/2
C
W
/2
C
W
/2
C
W
/2
C
W
/4
C W
1/2" CW
/2
C
W
1/2" HW
1 1/4" C W
3/4" H W
MV-2
MV-2
1/2" C W
3/4" C W
IMB-1
EW-1
WC-1
WC-1
WC-2
WC-2
L-1
L-1
L-1
L-1
L-2
L-2
SH-1
SH-1
EWC-1
EWC-1
MS-1
U-1
L-2
L-2
L-2
L-2
L-2
L-2
WC-1
WC-2 WC-2
U-1
S-1
U-1
U-1
FD-2
3" SS
3" S
SFD-1
3" S S
2" S S
FCO
3" S S
V
V
V
FD-1
/2
V
3" SS
/2
V
V
FD-2
S S
/2
V
V
VTR
/2
V
/2
V
/2
V
/2
V
/2
V
4" SS
3" S S
FD-2
2" V 2" V
2" V
2" V
2" V
/2
V
AAV-1
2" SS
MS-1
MV-3
1" C W
3/4" HW
R
3/4" HW
R
C W
H W
H W
1" H W
MV-2
BV-1
BV-1
EWH-S-1
/4
C
W
/4
H
W
BV-1
MV-21" HW
1" HW
FIXTURE UNITS 1-11 12-32 33-60 61-113 114-154 155-330
PDI UNITS A B C D E F
WATER HAMMER ARRESTOR SIZING AND SELECTION TABLE
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:1
:0
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_ O p ti o n
T w o
R e v it
B
IM
.r v t
P502-2
PLUMBING RISER
DIAGRAMS - ALTERNATE
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
A
1 FIRST FLOOR SOUTH BUILDING - PRESSURE RISER DIAGRAM
2 FIRST FLOOR SOUTH BUILDING - GRAVITY RISER DIAGRAM
3 ENLARGED WATER HEATER PLAN
PLUMBING FIXTURE SCHEDULE
PRESSURE ASSISTED, COLOR WHITE, VITREOUS CHINA, FLOOR MOUNTED TANK TYPE, 15-1/2" HIGH TO TOP OF BOWL, FLOOR OUTLET, ELONGATED BOWL, 1.0 GALLON PER FLUSH, WHITE OPEN FRONT PLASTIC SEAT. COORDINATE TANK WITH GRAB BAR WITH ARCH PLANS AND GRAB BAR INSTALLER PRIOR TO PIPING
ROUGH-IN.
MODEL NUMBERS AND DESCRIPTION
KOHLER: K-3531-T
ACCEPTABLE MANUFACTURERS
TOILET ROOMS - CAST IRON BODY, BOTTOM OUTLET, TAPPED FOR TRAP PRIMER, 5X5 SQUARE STRAINER, COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS, ADJUSTABLE SQUARE NICKEL BRONZE TOP, VANDAL PROOF. PROVIDE TRAP GUARD (TG-1).
3/4" MALE HOSE THREAD, NO LEAD SOLDER, STANDARD "O" SIZE SEAT WASHER, VACUUM BREAKER, LOOSE TEE KEY. PROVIDE STEM LOCK KIT.
FINISHED FLOORS, CAST IRON ADJUSTABLE FLOOR LEVEL CLEANOUT ASSEMBLY WITH ROUND NICKEL BRONZE TOP AND PLUG, WITH INVERTED HUB AND NEOPRENE
GASKET.
TERRAZZO MOP SINK, FLOOR MOUNTED, 36" X 36" X 12". FAUCET WITH CERAMIC DISC CARTRIDGES, BUCKET HOOK, ROD SUPPORT TO WALL AND VACUUM BREAKER.
FACTORY INSTALLED DRAIN, MOP BRACKET, HOSE AND RACK. PROVIDE 36" HIGH WALL GUARDS.
WHITE ACID RESISTING VITREOUS CHINA, WALL HUNG, 4" CENTERS, COLD AND TEMPERED WATER, SELF-CLOSING METERING FAUCET, VANDAL RESISTANT, 1-1/4" GRID DRAIN WITH 1-1/4" OD TAILPIECE, CHROME PLATED BRASS, 1-1/4" "P" TRAP, WITH CO PLUG, CHROME PLATED BRASS LOOSE-KEY ANGLE STOPS WITH FLEXIBLE RISERS AND TO FLOOR FIXTURE SUPPORT. PROVIDE VANDAL PROOF AND LEAD FREE FAUCET AND PUSH BUTTON ASSEMBLY. FAUCET AND DECK PLATE MUST INTERLOCK.
INSULATE P-TRAP AND SUPPLIES IN ACCORDANCE WITH ADA. PROVIDE FAUCET WITH A 0.5 GPM AERATOR.
CAST IRON ADJUSTABLE FLOOR LEVEL CLEANOUT ASSEMBLY WITH ROUND NICKEL BRONZE TOP AND PLUG, WITH INVERTED HUB AND NEOPRENE GASKET
KOHLER: K-4731-SC
FIXTURE: SEAT:
ELKAY: VRCTL8SC
HALSEY TAYLOR: HVR8BL
FIXTURE:
STERN-WILLIAMS: HL-2000
FIXTURE:
FAUCET:
STERN-WILLIAMS: T-10-VB
ZURN: 843M1-RC
T&S BRASS: B-665-BSTR
ASSE 1070, PISTON-CONTROL MECHANISM, POSITIVE SHUTOFF OF HOT WATER WHEN COLD WATER SUPPLY IS LOST, BRONZE BODY AND CAP WITH REPLACEABLE CORROSION-RESISTANT COMPONENTS, INCLUDING STAINLESS STEEL PISTON AND LINER. ADJUSTABLE SETPOINT SET AT 105° BRADLEY: S59-4000
WATTS: LFMMV-UT-M1
LEONARD: LF-170-CP-BRKT
FIXTURE:
WATTS: FD-100-M5-3-P-5-6
JOSAM: 3000-5S-VP-Y
ZURN: ZN415S-VP
FIXTURE:
WATTS: FD-100-B5-3-P-8
JOSAM: 3000-7E-80-Y
ZURN: ZN415H-Y
FIXTURE:
FIXTURE:
ZURN: ZN1400-BP
WATTS: CO-200-R-P-US
MIFAB: C1100-1-BA-P
FIXTURE:
ZURN: ZN1400
WATTS: CO-200-R-P-US
FIXTURE:
FIXTURE: FAUCET:
ZURN: Z5344
AMERICAN STANDARD: 0355.012
MECHANICAL ROOMS - CAST IRON BODY, BOTTOM OUTLET, 7" DIAMETER ROUND STRAINER, COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS, ADJUSTABLE ROUND NICKEL BRONZE TOP, VANDAL PROOF. PROVIDE WITH TRAP GUARD (TG-1).
HUB DRAIN - MECHANICAL ROOMS - CAST IRON BODY, BOTTOM OUTLET, 8" TO 8 5/8" DIAMETER ROUND HUB FUNNEL, COMBINATION INVERTIBLE MEMBRANE CLAMP AND
ADJUSTABLE COLLAR WITH SEEPAGE SLOTS. PROVIDE TRAP GUARD (TG-1). ZURN: Z127
JOSAM: 22540
FIXTURE:
WHITE ACID RESISTING VITREOUS CHINA, WALL MOUNTED, 3/4" TOP SPUD 0.125 GALLON WASHOUT JET, TO FLOOR FIXTURE SUPPORT AND CHROME-PLATED
DIAPHRAGM TYPE FLUSH VALVE.
FLUSH VALVE:
ZURN: Z5755-U
AMERICAN STANDARD: 6590.001.020
ZURN Z6003AV-ULF
SLOAN REGAL 186-0.125
AMERICAN STANDARD: 6145013.002
FIXTURE:
3/4" MALE HOSE THREAD, NO LEAD SOLDER, STANDARD "O" SIZE SEAT WASHER, VACUUM BREAKER, LOOSE TEE KEY.
WOODFORD: MODEL 24
MIFAB: MHY-9000
ZURN: Z1341-P34-RC
FIXTURE:
T & S BRASS B-0831-VF05
CHICAGO FAUCETS 802-VE2805-665ABCP
ZURN Z86500-XL-3M
ASSE 1070/1017, PISTON-CONTROL MECHANISM, POSITIVE SHUTOFF OF HOT WATER WHEN COLD WATER SUPPLY IS LOST, BRONZE BODY AND CAP WITH REPLACEABLE CORROSION-RESISTANT COMPONENTS, INCLUDING STAINLESS STEEL PISTON AND LINER. SET AT 105. 110 FOR KITCHEN HOSE BIBS FOR PRESSURE WASHERS. BRADLEY: S59-4016N WITH S45-2456 MOUNTING BRACKET
WATTS: LFMMV-UT-M1
LEONARD: LF-270-CP-BRKT
FIXTURE:
CONTRACTOR SHALL SUPPLY, INSTALL AND MAKE CONNECTIONS FOR THE WATER SUPPLY WITH A SHUT OFF VALVE AND WATER HAMMER ARRESTER FOR THE ICE
MAKER BOX. GUY GRAY: MIB1AB
FIXTURE:
COATED CAST IRON BACKWATER VALVE. OFFSET TYPE BRONZE FIXED SWING CHECK VALVE ASSEMBLY. BOLTED GASKETED COVER AND NO-HUB CONNECTIONS.
PROVIDE HDPE VALVE BOX. WATTS: BV-200
JOSAM: 67400
ZURN: Z1090
FIXTURE:
ASSE 1017, LIQUID-FILLED THERMAL MOTOR & PISTON CONTROL MECHANISM OR SOLID BI-METAL THERMOSTAT DIRECTLY LINKED TO VALVE PORTING, EQUIPPED WITH INTEGRAL CHECK STOPS, THERMOMETER & REMOVABLE STRAINERS. VALVE CONTROLS TEMPERATURE WITHIN 3 DEG F FROM A LOW FLOW TO A MAX FLOW RATE FOR A GIVEN PRESSURE DIFFERENTIAL. MIXING VALVE SHALL HAVE POSITIVE SHUTOFF OF HOT WATER WHEN COLD WATER SUPPLY IS LOST. PROVIDE FACTORY MOUNTING
BRACKET FOR INSTALLATION.
BRADLEY: S59-2025-R-H-T-B-P
LEONARD: TM-26-BDT-LF
FIXTURE:
MIFAB: C1100-1-BA-P
STOP VALVES:
MCQUIRE: LFBV2-09
BRASSCRAFT: KTSCR19X
FLEXIBLE SUPPLIES:
MCQUIRE: SSLAV12050038
BRASSCRAFT: B1-12A F
OFFSET GRID STRAINER:
MCQUIRE: 155WCSAN
ZURN: Z8746-PC
P-TRAP:
MCQUIRE: 8902
ZURN: Z8701-PC
ADA INSULATION KIT:
TRUEBRO: 103-EZ
ZURN: Z8946-3-NT
CARRIER:
ZURN: Z1231-79
JOSAM: 17100-67
WATTS: WCA-411-WC-US
CARRIER:
ZURN: Z1221
JOSAM: 17550-UR WATTS: CA-311
SURE SEAL: 2"=SS2009V, 3"=SS3009V, 4"=SS4009V
WOODFORD: MODEL 24, ZURN: Z1341-P34-RC
STEM LOCK: SL-24 STEM LOCK: Z1399-HGS
FIXTURE:
ADA COMPLIANT - TWO-LEVEL, WALL HUNG HEAVY GAUGE STEEL VANDAL-RESISTANT CABINET. CHROME PLATED BRASS VANDAL RESISTANT BUBBLER IS HEAVY DUTY, ONE PIECE CONSTRUCTION SATIN FINISH STAINLESS STEEL KEYED INTO POSITION TO PREVENT ROTATION. HEAVY DUTY PUSH BUTTON CONTROL IS VANDAL-RESISTANT. IN-LINE FLOW REGULATOR, LEAD FREE WATER SYSTEM PRE-COOLER AND TEMPERATURE CONTROLLER AND WALL BOX. 3000 GALLON FILTER, NSF AND 53 CERTIFIED. UNIT CAPACITY 8 GPH, 90F AMBIENT TEMPERATURE, 80F INLET WATER, 50F OUTLET WATER. UL RATED FOR INDOOR OR OUTDOOR USE.
FIXTURE NO. FIXTURE TYPE
WASTE
CONN.
VENT
CONN.
TRAP C.W. CONN. H.W. CONN.
WC-1 4"WATER CLOSET 2" INTEG. 3/4" -
4" 2" INTEG. 3/4" -WC-2 WATER CLOSET
DEVICE TO PREVENT SEWER GASSES FROM ESCAPING THROUGH P-TRAP.
JR SMITH: 3960
2" 1-1/2" 1-1/4" 1/2" 1/2"L-1 LAVATORY
2" 1-1/2" 1-1/4" 1/2" 1/2"L-2 LAVATORY
2" 1-1/2" INTEG. 3/4" -UR-1 URINAL
2" 1-1/2" 1-1/2" 1/2" 1/2"S-1 SINK
2" 1-1/2" 1-1/2" 1/2" -ELECTRIC WATER
COOLER (BI-LEVEL)
EWC-1
MS-1 MOP SINK 3" 1-1/2" 3" 3/4" 3/4"
- - - 1/2" 1/2"MV-1 MIXING VALVE
(SINGLE FIXTURE)
MIXING VALVE
(MULTIPLE FIXTURES)
MV-2 - - - 3/4" 3/4"
MIXING VALVEMV-3 - - - 3/4" 3/4"
- - - 3/4" -HB-1
HB-2
HOSE BIBB
HOSE BIBB - - - 3/4" -
FD-1 FLOOR DRAIN 3" 1-1/2" 3" - -
FD-2 FLOOR DRAIN 3" 1-1/2" 3" - -
TG-1 TRAP GUARD 3" - -- -
IMB-1 ICE MAKER BOX -- - 1/2" -
FCO FLOOR CLEANOUT 4" - - --
4" - - --ECO EXTERIOR CLEANOUT
HD-1 HUB DRAIN 2" - - --
- - --3"
BWV-1 BACKWATER VALVE
ZURN: 2"=Z1072-2, 3"=Z1072-3, 4"=Z1072-4
SHOWER (ADA)SH-1 2" 1-1/2" 1/2" 1/2"
SHOWER (ADA) - PROVIDE AND INSTALL PRESSURE BALANCING SHOWER FITTING, SHOWER HEAD, HAND HELD SHOWER (1.5 GPM) WITH 60" HOSE AND 24" SLIDE BART, 2” DRAIN - CAST IRON BODY, FLASHING CLAMP AND ADJUSTABLE 5" ROUND BRONZE TOP, "P" TRAP WITH DEEP SEAL TRAP. BRADLEY: IC-C5-B24
SYMMONS: C-96-300-B30-V-X-1.5
FIXTURE: SHOWER DRAIN:
ZURN: ZN415-VP-5B
WATTS: FD-100-A5F
2"
WHITE ACID RESISTING VITREOUS CHINA, COUNTERTOP LAVATORY, 4" CENTERS, COLD AND TEMPERED WATER, SELF-CLOSING METERING FAUCET, VANDAL RESISTANT, 1-1/4" GRID DRAIN WITH 1-1/4" OD TAILPIECE, CHROME PLATED BRASS, 1-1/4" "P" TRAP, WITH CO PLUG, CHROME PLATED BRASS WHEEL HANDLE ANGLE STOPS WITH FLEXIBLE RISERS PROVIDE VANDAL PROOF AND LEAD FREE FAUCET AND PUSH BUTTON ASSEMBLY. FAUCET AND DECK PLATE MUST INTERLOCK. PROVIDE FAUCET
WITH A 0.5 GPM AERATOR.
FIXTURE: FAUCET:
ZURN: Z5110
AMERICAN STANDARD: 0476.028
CHICAGO FAUCETS 802-VE2805-665ABCP
FLEXIBLE SUPPLIES:
MCQUIRE: SSLAV12050038
BRASSCRAFT: B1-12A F
OFFSET GRID STRAINER:
MCQUIRE: 155WCSAN
ZURN: Z8746-PC
P-TRAP:
MCQUIRE: 8902
ZURN: Z8701-PC
ADA COMPLIANT - PRESSURE ASSISTED, COLOR WHITE, VITREOUS CHINA, FLOOR MOUNTED TANK TYPE, 17-1/8" HIGH TO TOP OF BOWL, FLOOR OUTLET, ELONGATED BOWL, 1.0 GALLON PER FLUSH, WHITE OPEN FRONT PLASTIC SEAT. COORDINATE TANK WITH GRAB BAR WITH ARCH PLANS AND GRAB BAR INSTALLER PRIOR TO PIPING ROUGH-IN. CONTRACTOR SHALL COORDINATE FLUSH HANDLE WITH OPEN SIDE OF RESTROOM.
ADA COMPLIANT SINK - TYPE 304 18 GAUGE STAINLESS STEEL, SINGLE BOWL, SELF RIMMING, SOUND DEADENED, 19 "X 18"X 6-1/2" DEEP BOWL, OFF-CENTER DRAIN
(CENTER BACK), SINGLE HOLE PUNCH, TOP SURFACES FULLY POLISHED, GOOSENECK FAUCET, COLD AND HOT WATER, CUP STRAINER AND CHROME PLATED BRASS
P-TRAP WITH CO PLUG AND CHROME PLATED BRASS WHEEL HANDLE ANGLE STOPS WITH 12" FLEXIBLE RISERS. PROVIDE FAUCET WITH 0.5 GPM AERATOR.
CHICAGO 786-E3VPCABCP
FIXTURE: FAUCET:
ELKAY: LRAD191865PD
KOHLER: K-3519-T KOHLER: K-4731-SC
FIXTURE: SEAT:
AUTOMATIC TYPE - SELF-ACTING THERMOSTATIC RECIRCULATION VALVE WHICH AUTOMATICALLY AND CONTINUOUSLY MAINTAINS THE END OF EACH DOMESTIC HOT WATER SUPPLY LINE AT THE SPECIFIED WATER TEMPERATURE. MANUAL TYPE -LEAD-FREE, FIXED ORIFICE DESIGN, GLOBE PATTERN, INTEGRAL INTERNAL MEMORY
STOP, FLOW MEASUREMENT ACCURACY +/- 3%
FIXTURE:
AUTOMATIC - THERM OMEGA TECH: CIRCUIT SOLVER
MANUAL - NIBCO: 1810-LF SERIES FLO-BOSS M
BV-1 BALANCING VALVE
BARRIER-FREE EMERGENCY EYE AND FACEWASH STATION, STAINLESS STEEL CONSTRUCTION, PEDESTAL MOUNT WITH FOOT PEDAL ACTIVATION. FIXTURE:
BRADLEY: S19214SS- - ---
EW-1 EMERGENCY
EYEWASH
AIR ADMITTANCE VALVE FIXTURE:
STUDOR: MNI-VENT #20301- - ---
AAV-1 AIR ADMITTANCE
VALVE
NOTES:
1. SET AT 140 DEGREES FAHRENHEIT.
2. PROVIDE THERMAL EXPANSION TANK AS SCHEDULED.
3. PROVIDE WATER HEATER SUPPORT AS SCHEDULED.
4. PROVIDE CIRCULATOR PUMP AS SCHEDULED.
80 AND ABOVE
4" HOUSE
KEEPING PAD
- FIELD POURED
40 AND 50 STAND - HOLDRITE / 40-S-30-U
20 AND 30 STAND - HOLDRITE / 40-S-24-U
30 SHELF - CONTRACTOR SHALL PAD SIDES AND CORNERS OF SHELF. HOLDRITE / 50-SWHP-W
20 SHELF - CONTRACTOR SHALL PAD SIDES AND CORNERS OF SHELF. HOLDRITE / 40-SWHP-W
WATER HEATER
GALLONS
TYPE - REMARKS
WATER HEATER SUPPORT
TET - 2 EWH - N-2 -
THERMAL EXPANDION TANK SHALL BE MOUNTED ON WALL OR
FLOOR AS NOTED ON PLANS
WATTS: PLT-20
AMTROL: ST-25V
TET-1 EWH-N-1 -
THERMAL EXPANSION TANK SHALL BE MOUNTED ON WALL WITH
MANUFACTURED EXPANSION TANK WALL BRACKET.
WATTS: PLT-5
AMTROL: ST-5
TAG
SERVING WATER
HEATER
- REMARKS
THERMAL EXPANSION TANK SCHEDULE
AQST CP-1 -
AQUASTAT CONTROLLER SHALL HAVE HIGH AND LOW LIMIT
CIRCULATOR CONTROL, TEMPERATURE RANGE: 100 DEG. F TO
240 DEG. F, DIFFERENTIAL 5 DEG F TO 30 DEG. F.
HONEYWELL: L6006A
TAG
SERVING CIRC.
PUMP
- REMARKS
AQUASTAT SCHEDULE
- PLUMBING EQUIPMENT SCHEDULE -
FIXTURE UNITS 1-11 12-32 33-60 61-113 114-154 155-330
PDI UNITS A B C D E F
WATER HAMMER ARRESTOR SIZING AND SELECTION TABLE
- ELECTRIC WATER HEATER SCHEDULE -
WATER
HEATER TAG
LOCATED ON SHEET/ROOM
ACCEPTABLE
MANUFACTURERS /
MODEL NUMBERS
ELECTRICAL RECOVERY
(GPH) 72 DEG.
DELTA T
STORAGE
(GAL.)
REMARKSTOTAL KW /
VOLT. / PH.
NON/SIMULTANEOUS
EWH-N-1 CUSTODIAL 139
A.O. SMITH: DEL-20
STATE: PCE 20 1OMSA
3/120 V/1 NONSIMULTANEOUS 17 20 2,3
EWH-S-1 CUSTODIAL 103
A.O. SMITH: DEL-20
STATE: PCE 20 1OMSA
3/120 V/1 NONSIMULTANEOUS 17 20 1,2,3,4
CIRCULATOR PUMP SCHEDULE
- WATER HEATER CIRCULATOR PUMP AND EQUIPMENT SCHEDULE -
CIRCULATOR
PUMP TAG
SERVING
WATER HEATER
HP / VOLT. REMARKS
ACCEPTABLE
MANUFACTURERS /
MODELS
CP-S-1 EWH 1/25 / 120 V
INLINE PUMP CONTROLLED BY BAS AND AQUASTAT. PUMP
PROVIDED WITH INTEGRAL FLOW CHECK.
TACO 009-SF6-I IFC
CP-S-2 EWH 1/25 / 120 V
INLINE PUMP CONTROLLED BY BAS AND AQUASTAT. PUMP
PROVIDED WITH INTEGRAL FLOW CHECK.
TACO 009-SF6-I IFC
a. THE FITTINGS SHALL ONLY BE PERMITTED FOR A 2-INCH OR SMALLER FIXTURE DRAIN.
b. THREE INCHES OR LARGER.
c. FOR A LIMITATION ON DOUBLE SANITARY TEES, SEE SECTION 706.3.
COMBINATION WYE AND EIGTH BEND X X X
WYE X X X
SANITARY TEE X (c) --- ---
LONG SWEEP X X X
SHORT BEND X X (a,b) X (a)
QUARTER BEND X X (a) X (a)
SIXTH BEND X X X
EIGTH BEND X X X
SIXTEENTH BEND X X X
HORIZONTAL TO
VERTICAL
VERTICAL TO
HORIZONTAL
HORIZONTAL TO
HORIZONTAL
TYPE OF FITTING PATTERN
CHANGE IN DIRECTION
FLORIDA BUILDING CODE - TABLE 706.3 - FITTINGS FOR CHANGE IN DIRECTION
* TABLE HAS BEEN TRUNCATED TO DEPICT ONLY PIPE SIZES RELEVANT TO
PROJECT. REFER TO FLORIDA BUILDING CODE FOR ADDITIONAL PIPE SIZES.
3/4 3 0.5 21
1/2 1.5 2 43
3/8 0.75 3 50
PUBLIC LAVATORY
FAUCETS
OTHER FIXTURES
AND APPLIANCES
NOMINAL
PIPE SIZE
(INCHES)
VOLUME
(LIQUID OUNCES/FOOT LENGTH)
MAXIMUM PIPE LENGTH (FEET)
FLORIDA BUILDING CODE - TABLE C404.5.1* - PIPING VOLUME AND MAXIMUM
LENGTHS
a. FOR PIPING SMALLER THAN 1-1/2 INCHES AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1 INCH SHALL BE PERMITTED (BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE b) BUT NOT TO A
THICKNESS LESS THAN 1 INCH.
b. FOR INSULATION OUTSIDE THE STATED CONDUCTIVITY RANGE, THE MINIMUM THICKNESS (T) SHALL BE DETERMINED AS FOLLOWS:
T=r{(1 + t/r)K/k - 1}
WHERE:
T = MINIMUM INSULATION THICKNESS
r = ACTUAL OUTSIDE RADIUS OF PIPE t = INSULATION THICKNESS LISTED IN TABLE
K = CONDUCTIVITY OF THE ALTERNATE MATERIAL AT MEAN RATING TEMPERATURE INDICATED
k = THE UPPER VALUE OF THE CONDUCTIVTY RANGE LISTED
c. FOR DIRECT-BURIED HEATING AND HOT WATER SYSTEM PIPING, REDUCTION OF THESE THICKNESSES BY 1-1/2 INCHES SHALL BE...
< 40 0.20 - 0.26 50 0.5 1.0 1.0 1.0 1.5
40 - 60 0.21 - 0.27 75 0.5 1.0 1.0 1.0 1.0
105 - 140 0.21 - 0.28 100 1.0 1.0 1.5 1.5 1.5
141 - 200 0.25 - 0.29 125 1.5 1.5 2.0 2.0 2.0
201 - 250 0.27 - 0.30 150 2.5 2.5 2.5 3.0 3.0
251 - 350 0.29 - 0.32 200 3.0 4.0 4.5 4.5 4.5
> 350 0.32 - 0.34 250 4.5 5.0 5.0 5.0 5.0
CONDUCTIVITY
BTU x IN. / (H x FT² x °F)ᵇ
MEAN RATING
TEMPERATURE, °F
< 1 1 TO < 1-1/2 1-1/2 TO < 4 4 TO 8 ≥ 8
FLUID OPERATING
TEMPERATURE
RANGE AND USAGE
(°F)
INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE (INCHES)
FLORIDA BUILDING CODE 8th EDITION (2023) - TABLE C403.2.10 - MINIMUM PIPE INSULATION THICKNESS (INCHES) ͣ , ᵇ
MPE JOB #:
ENG. BUS. No. EB-0005096
CERT. OF AUTH. No. 5096
PHONE (239) 332-1187
12437 Brantley Commons Fort Myers, FL 33907
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PROJECT NO:
DATE:
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
2024-118
/2
/2
:0
:4
P
M
A u to d e s k D o c s /W a re h o u s e
C o n v e rt t o
P a rk s
R e c D e p a rt m e n t/
-1
P lu m b in g M o d e l_
O p ti o n O n e
R e v it
B
IM
.r v t
P601
PLUMBING SCHEDULES
40-24105
W A
R E
H O
U S
E C
O N
V E
R T
T O
P A
R K
S
R E
C D
E P
T
C
IT
Y O
F F
O R
T M
Y E
R S
06/19/2025
PERMIT DOCUMENTS
M
IC
H
IH
A
N A
V E
N U
E F
O R
T M
Y E
R S
F
L O
R
ID
PLUMBING FIXTURE SCHEDULE
PRESSURE ASSISTED, COLOR WHITE, VITREOUS CHINA, FLOOR MOUNTED TANK TYPE, 15-1/2" HIGH TO TOP OF BOWL, FLOOR OUTLET, ELONGATED BOWL, 1.0 GALLON PER FLUSH, WHITE OPEN FRONT PLASTIC SEAT. COORDINATE TANK WITH GRAB BAR WITH ARCH PLANS AND GRAB BAR INSTALLER PRIOR TO PIPING
ROUGH-IN.
MODEL NUMBERS AND DESCRIPTION
KOHLER: K-3531-T
ACCEPTABLE MANUFACTURERS
TOILET ROOMS - CAST IRON BODY, BOTTOM OUTLET, TAPPED FOR TRAP PRIMER, 5X5 SQUARE STRAINER, COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS, ADJUSTABLE SQUARE NICKEL BRONZE TOP, VANDAL PROOF. PROVIDE TRAP GUARD (TG-1).
3/4" MALE HOSE THREAD, NO LEAD SOLDER, STANDARD "O" SIZE SEAT WASHER, VACUUM BREAKER, LOOSE TEE KEY. PROVIDE STEM LOCK KIT.
FINISHED FLOORS, CAST IRON ADJUSTABLE FLOOR LEVEL CLEANOUT ASSEMBLY WITH ROUND NICKEL BRONZE TOP AND PLUG, WITH INVERTED HUB AND NEOPRENE
GASKET.
TERRAZZO MOP SINK, FLOOR MOUNTED, 36" X 36" X 12". FAUCET WITH CERAMIC DISC CARTRIDGES, BUCKET HOOK, ROD SUPPORT TO WALL AND VACUUM BREAKER.
FACTORY INSTALLED DRAIN, MOP BRACKET, HOSE AND RACK. PROVIDE 36" HIGH WALL GUARDS.
WHITE ACID RESISTING VITREOUS CHINA, WALL HUNG, 4" CENTERS, COLD AND TEMPERED WATER, SELF-CLOSING METERING FAUCET, VANDAL RESISTANT, 1-1/4" GRID DRAIN WITH 1-1/4" OD TAILPIECE, CHROME PLATED BRASS, 1-1/4" "P" TRAP, WITH CO PLUG, CHROME PLATED BRASS LOOSE-KEY ANGLE STOPS WITH FLEXIBLE RISERS AND TO FLOOR FIXTURE SUPPORT. PROVIDE VANDAL PROOF AND LEAD FREE FAUCET AND PUSH BUTTON ASSEMBLY. FAUCET AND DECK PLATE MUST INTERLOCK.
INSULATE P-TRAP AND SUPPLIES IN ACCORDANCE WITH ADA. PROVIDE FAUCET WITH A 0.5 GPM AERATOR.
CAST IRON ADJUSTABLE FLOOR LEVEL CLEANOUT ASSEMBLY WITH ROUND NICKEL BRONZE TOP AND PLUG, WITH INVERTED HUB AND NEOPRENE GASKET
KOHLER: K-4731-SC
FIXTURE: SEAT:
ELKAY: VRCTL8SC
HALSEY TAYLOR: HVR8BL
FIXTURE:
STERN-WILLIAMS: HL-2000
FIXTURE:
FAUCET:
STERN-WILLIAMS: T-10-VB
ZURN: 843M1-RC
T&S BRASS: B-665-BSTR
ASSE 1070, PISTON-CONTROL MECHANISM, POSITIVE SHUTOFF OF HOT WATER WHEN COLD WATER SUPPLY IS LOST, BRONZE BODY AND CAP WITH REPLACEABLE CORROSION-RESISTANT COMPONENTS, INCLUDING STAINLESS STEEL PISTON AND LINER. ADJUSTABLE SETPOINT SET AT 105° BRADLEY: S59-4000
WATTS: LFMMV-UT-M1
LEONARD: LF-170-CP-BRKT
FIXTURE:
WATTS: FD-100-M5-3-P-5-6
JOSAM: 3000-5S-VP-Y
ZURN: ZN415S-VP
FIXTURE:
WATTS: FD-100-B5-3-P-8
JOSAM: 3000-7E-80-Y
ZURN: ZN415H-Y
FIXTURE:
FIXTURE:
ZURN: ZN1400-BP
WATTS: CO-200-R-P-US
MIFAB: C1100-1-BA-P
FIXTURE:
ZURN: ZN1400
WATTS: CO-200-R-P-US
FIXTURE:
FIXTURE: FAUCET:
ZURN: Z5344
AMERICAN STANDARD: 0355.012
MECHANICAL ROOMS - CAST IRON BODY, BOTTOM OUTLET, 7" DIAMETER ROUND STRAINER, COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS, ADJUSTABLE ROUND NICKEL BRONZE TOP, VANDAL PROOF. PROVIDE WITH TRAP GUARD (TG-1).
HUB DRAIN - MECHANICAL ROOMS - CAST IRON BODY, BOTTOM OUTLET, 8" TO 8 5/8" DIAMETER ROUND HUB FUNNEL, COMBINATION INVERTIBLE MEMBRANE CLAMP AND
ADJUSTABLE COLLAR WITH SEEPAGE SLOTS. PROVIDE TRAP GUARD (TG-1). ZURN: Z127
JOSAM: 22540
FIXTURE:
WHITE ACID RESISTING VITREOUS CHINA, WALL MOUNTED, 3/4" TOP SPUD 0.125 GALLON WASHOUT JET, TO FLOOR FIXTURE SUPPORT AND CHROME-PLATED
DIAPHRAGM TYPE FLUSH VALVE.
FLUSH VALVE:
ZURN: Z5755-U
AMERICAN STANDARD: 6590.001.020
ZURN Z6003AV-ULF
SLOAN REGAL 186-0.125
AMERICAN STANDARD: 6145013.002
FIXTURE:
3/4" MALE HOSE THREAD, NO LEAD SOLDER, STANDARD "O" SIZE SEAT WASHER, VACUUM BREAKER, LOOSE TEE KEY.
WOODFORD: MODEL 24
MIFAB: MHY-9000
ZURN: Z1341-P34-RC
FIXTURE:
T & S BRASS B-0831-VF05
CHICAGO FAUCETS 802-VE2805-665ABCP
ZURN Z86500-XL-3M
ASSE 1070/1017, PISTON-CONTROL MECHANISM, POSITIVE SHUTOFF OF HOT WATER WHEN COLD WATER SUPPLY IS LOST, BRONZE BODY AND CAP WITH REPLACEABLE CORROSION-RESISTANT COMPONENTS, INCLUDING STAINLESS STEEL PISTON AND LINER. SET AT 105. 110 FOR KITCHEN HOSE BIBS FOR PRESSURE WASHERS. BRADLEY: S59-4016N WITH S45-2456 MOUNTING BRACKET
WATTS: LFMMV-UT-M1
LEONARD: LF-270-CP-BRKT
FIXTURE:
CONTRACTOR SHALL SUPPLY, INSTALL AND MAKE CONNECTIONS FOR THE WATER SUPPLY WITH A SHUT OFF VALVE AND WATER HAMMER ARRESTER FOR THE ICE
MAKER BOX. GUY GRAY: MIB1AB
FIXTURE:
COATED CAST IRON BACKWATER VALVE. OFFSET TYPE BRONZE FIXED SWING CHECK VALVE ASSEMBLY. BOLTED GASKETED COVER AND NO-HUB CONNECTIONS.
PROVIDE HDPE VALVE BOX. WATTS: BV-200
JOSAM: 67400
ZURN: Z1090
FIXTURE:
ASSE 1017, LIQUID-FILLED THERMAL MOTOR & PISTON CONTROL MECHANISM OR SOLID BI-METAL THERMOSTAT DIRECTLY LINKED TO VALVE PORTING, EQUIPPED WITH INTEGRAL CHECK STOPS, THERMOMETER & REMOVABLE STRAINERS. VALVE CONTROLS TEMPERATURE WITHIN 3 DEG F FROM A LOW FLOW TO A MAX FLOW RATE FOR A GIVEN PRESSURE DIFFERENTIAL. MIXING VALVE SHALL HAVE POSITIVE SHUTOFF OF HOT WATER WHEN COLD WATER SUPPLY IS LOST. PROVIDE FACTORY MOUNTING
BRACKET FOR INSTALLATION.
BRADLEY: S59-2025-R-H-T-B-P
LEONARD: TM-26-BDT-LF
FIXTURE:
MIFAB: C1100-1-BA-P
STOP VALVES:
MCQUIRE: LFBV2-09
BRASSCRAFT: KTSCR19X
FLEXIBLE SUPPLIES:
MCQUIRE: SSLAV12050038
BRASSCRAFT: B1-12A F
OFFSET GRID STRAINER:
MCQUIRE: 155WCSAN
ZURN: Z8746-PC
P-TRAP:
MCQUIRE: 8902
ZURN: Z8701-PC
ADA INSULATION KIT:
TRUEBRO: 103-EZ
ZURN: Z8946-3-NT
CARRIER:
ZURN: Z1231-79
JOSAM: 17100-67
WATTS: WCA-411-WC-US
CARRIER:
ZURN: Z1221
JOSAM: 17550-UR WATTS: CA-311
SURE SEAL: 2"=SS2009V, 3"=SS3009V, 4"=SS4009V
WOODFORD: MODEL 24, ZURN: Z1341-P34-RC
STEM LOCK: SL-24 STEM LOCK: Z1399-HGS
FIXTURE:
ADA COMPLIANT - TWO-LEVEL, WALL HUNG HEAVY GAUGE STEEL VANDAL-RESISTANT CABINET. CHROME PLATED BRASS VANDAL RESISTANT BUBBLER IS HEAVY DUTY, ONE PIECE CONSTRUCTION SATIN FINISH STAINLESS STEEL KEYED INTO POSITION TO PREVENT ROTATION. HEAVY DUTY PUSH BUTTON CONTROL IS VANDAL-RESISTANT. IN-LINE FLOW REGULATOR, LEAD FREE WATER SYSTEM PRE-COOLER AND TEMPERATURE CONTROLLER AND WALL BOX. 3000 GALLON FILTER, NSF AND 53 CERTIFIED. UNIT CAPACITY 8 GPH, 90F AMBIENT TEMPERATURE, 80F INLET WATER, 50F OUTLET WATER. UL RATED FOR INDOOR OR OUTDOOR USE.
FIXTURE NO. FIXTURE TYPE
WASTE
CONN.
VENT
CONN.
TRAP C.W. CONN. H.W. CONN.
WC-1 4"WATER CLOSET 2"…
This is the start of the file's text. The full file is on GovTribe.