CFM_Parks_and_Rec_-_Landscape_Plans_-_North_Parcel.pdf
PDF 3 MB Posted
- Attached to
- Michigan Avenue Warehouse Renovation
- Solicitation number
- ITB 25-098
- Issued by
- Lee County, Fruitville CDP, Florida
About this file
This document is a comprehensive landscape and irrigation plan for the C.F.M. - Parks and Recreation North Parcel Addition project located in Fort Myers, Florida, prepared by David M. Jones and Associates, Inc. The site is a commercial development spanning 81,840 square feet (approximately 1.87 acres), with two existing warehouses and planned landscape improvements. The plan details specific landscape requirements, including 19,010 square feet of open space (exceeding the 16,368 square feet required), 23 required and provided tree credits, and buffer plantings along Michigan Avenue and Palm Avenue. The landscape design includes a mix of native and non-native plant species such as Yellow Tabebuia, Washingtonia Palms, Coccoloba diversifolia, Conocarpus erectus, and various shrubs like Coco Plum and Dwarf Clusia.
The irrigation plan is comprehensive, utilizing a Hunter irrigation system with a 16-station outdoor modular controller, multiple remote control valves, and a water meter. The system is designed with PVC Schedule 40 piping, including 2,086 linear feet of 1-inch lateral lines, 270 linear feet of 1.5-inch lateral lines, and 802.6 linear feet of 2-inch mainlines. The project includes specific requirements for plant material quality, mulching, and maintenance, with a focus on removing exotic vegetation and ensuring proper installation and establishment of the landscape. The irrigation system will be based on a minimum operating pressure of 40 PSI and will use an irrigation well as the water source, with the final system design required to comply with South Florida Water Management District water use permit parameters.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Michigan ave.
S
SS
EXISTING
WAREHOUSE #1
EXISTING
WAREHOUSE #2
P A
LM
a v e
MATCHLINE
OVERHEAD POWER LINES
O V
E R
H E
A D
P O
W E
R L
IN
E
S
1 - BUC BU2
1 - BUC BU2
1 - QUE VI5
3 - ADO MRR
1 - BUC BU2
2 - SWI MA2
1 - QUE VI4
12 - SWI MA2
EXIST. TO REMAIN
EXIST. TO BE
REMOVED
EXIST. TO REMAIN
EXIST. TO REMAIN
EXIST. TO REMAIN
EXIST. TO REMAIN
EXIST. TO REMAIN
EXIST. TO REMAIN
1 - QUE VI5
1 - SWI MA3
EXIST. TO BE
REMOVED
EXIST. TO BE
REMOVED
6 - TAX DI4
EXIST. TO BE
REMOVED
2"
2"
2"
112"
SITE PLAN AND
CALCULATIONS
L - 1-N
SITE LANDSCAPE CALCULATIONS
SCALE 1" = 30'
0' 15' 30' 60' 90'
Landscape Calculations Site Data( Work Area) Site Use: Commercial Site Area: 81,840 S.F. (~1.87 AC) F.L.U.M.: Commercial
Open Space Requirements Commercial developments require 20% open space 81,840 S.F. Development x 20% = 16,368 sf required Open space provided = 19,010 S.F. provided per hatching shown.
General On-Site Tree Requirements Commercial developments require 1 tree per 5,000 sf.
81,840 s.f. / 3,500 = 23 Tree credits required and 23 tree credits provided, labeled as (G) or (G+).
Internal Parking Landscape Requirement Internal landscape areas of 10% of the parking area is required.
5,228 s.f. x10% =522 s.f. REQUIRED and 920 s.f. PROVIDED PER
HATCHING SHOWN.
Per Sec 138-41(3), Curbed parking islands, peninsulas and medians Require 1 Tree and 10 Shrubs per 200 s.f.
522 s.f. Parking Islands exist /200 s.f. = 3 Trees Required and 3 Provided, labeled as (P) Parking.
522 s.f. Parking Islands exist /200 s.f. x 10 Shrubs = 26 Shrubs Required and 26 Provided, labeled as (P).
Building Perimeter Planting A required 10% of the proposed gross footprint must be provided for the building perimeter planting area.
Abutting all side excluding loading area, with 5' width and maximum of 10% of total area as turf.
WAREHOUSE #1
10,220 sf X 10% = 1,022 sf required and 1,330 sf provided
WAREHOUSE #2
7,113 sf X 10% = 713 sf required and 1,010sf provided
Buffer Requirements
NORTH BUFFER:
No Buffer Required
EAST BUFFER:
OFFICE TO MF
10' Type 'A' Required;
4 Trees and 33 shrubs per 100 lf.
530'/100 x 4 = 22 Trees Required and 22 Provided, labeled as (E.B.).
530'/100 x 33 = 175 Shrubs Required and 175 Provided, labeled as (E.B.).
SOUTH BUFFER:
COMMERCIAL - R.O.W. (Michigan Ave.)
15' Type 'B' Required;
Required:
Michigan Avenue/Michigan Link, from Seaboard Street to Dr.
Martin Luther King, Jr. Boulevard:
a. Tree type: One (1) Yellow Tabebuia (Tabebuia caraiba) alternated with clusters of six (6) Washingtonia Palm (Washingtonia robusta)
b. Spacing: One (1) Yellow Tabebuia planted twenty feet (20′) from palm clusters; Six (6) Washingtonia palms planted in triangular clusters spaced ten feet (10′) apart.
c. Minimum size at planting: Yellow Tabebuia at twelve feet to fourteen feet in height (12′—14′H) with a five-foot spread (5′S) and a two and a half inch caliper (2-½″CAL).
Wahingtonia palms at staggered heights of ten to fourteen of clear trunk (10′—14′CT) with not less than two feet (2′) of stagger between palms.
NOTE: Alternate tree species utilized due to existing trees and overhead utilities.
135'/100 x 66 = 89 Shrubs Required and 89 Provided, labeled as (N.B.).
WEST BUFFER
COMMERCIAL - R.O.W. (Palm Ave.)
15' Type 'B' Required;
4 Trees and 66 shrubs per 100 lf.
540'/100 x 4 = 22 Trees Required and 22 Provided, labeled as (E.B.).
540'/100 x 66 = 356 Shrubs Required and 356 Provided, labeled as (E.B.).
PLAN SCALE REDUCED WHEN PRINTED 11x17
INTERNAL UTILITY EASEMENT - NO TREES OR LARGE
SHRUBS SHALL BE PLANTED INSIDE THESE ZONES.
ALL TREES IN ISLANDS ARE LOCATED OUTSIDE OF
EASEMENT, MIN. 10' FROM BACK OF CURB
N
SHEET TITLE:
SHEET NUMBER:
ISSUED DATE:
AND ASSOCIATES, INC.
LANDSCAPE ARCHITECTS
CONSULTANT:
DAVID M. JONES, JR.
AND PLANNERS
DESIGN PROFESSIONAL:
PROJECT NO.
PREPARED FOR:
REVISIONS:
PROJECT MJR:
FILE NAME:
DESIGNER:
CAD TECH:
CHECKED BY:
ISSUED FOR:
DMJA
GJD
GREGORY J. DISERIO
SEPT. 30, 2024
CALL 48 HOURS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811 Know what's BELOW.
Call before you dig.
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
2221 McGregor Blvd.
Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494
CFMPRF-N. PARCEL LS
C.F. M. - Parks and Recreation
North Parcel Addition
FORT MYERS, FL
PERMITTING
224036
Fort Myers, FL 1605 Hendry Street
Fort Myers, FL 33901 Phone: 239.418.0691
GJD
GJD
GREGORY J DISERIO, RLA
R.L.A. #: LA 0000840
STATE OF FLORIDA
OCT. 29, 2024 IRRIGATION
NOV. 15, 2024 EAST BUFFER
NOV. 20, 2024 SITE UPDATE
MARCH 11, 2025 SITE UPDATE
APRIL 28, 2025 ADDED FENCEJU
N E
, 2
D R
IV
E
C H
AN
G
E
JU
LY
3, BI
D
D O
C U
M
EN
T
GENERAL IRRIGATION NOTES
1. All mainline and lateral line piping and control wires under paving shall be installed in separate sleeves. main and lateral line sleeves shall be a minimum of twice (2x) the diameter of the pipe to be sleeved. Control wire sleeves shall be sufficient size for the required number of wires under paving.
2. Pipe sizes shall conform to those shown on the drawings. No substitutes of smaller pipe sizes shall be permitted but substitutions of larger sizes may be approved. All damaged and rejected pipe shall be removed from the site at the time of said rejection.
3. All sprinkler heads shall be set perpendicular to finished grade unless otherwise specified.
4. The irrigation contractor shall flush and adjust all sprinkler heads and valves for optimum coverage with minimal overspray onto walks, streets, walls, etc.
5. Irrigation heads shall be a minimum of 12" from buildings.
6. This design is diagrammatic. All piping, valves, etc. shown within paved areas are for design clarification only and shall be installed in planting areas whenever possible. The contractor shall locate all valves in shrub areas where possible.
7. It is the responsibility of the irrigation contractor to familiarize himself with all grade differences, location of walls, structures and utilities. The irrigation contractor shall repair or replace all items damaged by his work. He shall coordinate his work with other contractors for the location and installation of pipe sleeves through walls, under roadways and paving, etc.
8. Do not willfully install the sprinkler system as shown on the drawings when it is obvious in the field that unknown obstructions, grade differences, water levels or differences in the area dimensions exist that might not have been considered in the engineering. Such obstructions or differences should be brought to the attention of owners representative. In the event this notification is not performed, the irrigation contractor shall assume full responsibility for any revisions necessary.
9. All sprinkler equipment not otherwise detailed or specified shall be installed as per manufacturer's recommendations and specifications.
10. The contractor shall provide (Pressure Compensating Screens) as necessary to reduce or eliminate over spray into streets, walks or other areas as dictated by the owner's authorized representative.
11. All remote control valves, gate valves, quick couplers and control wire splices shall be installed in approved valve boxes with locking covers. All shall be marked indicating controller and station numbers for control valve.
12. Contractor to provide the Owner with a complete irrigation design in compliance with Owners program. All required plantings shall be irrigated.
13. Irrigation system shall be designed for complete coverage. Verify with owner limits of irrigation for sod prior to bidding.
14. The sprinkler system to be based on a minimum operating pressure of 40 PSI. The irrigation contractor shall verify water pressures, flows, elevations, and other requirements prior to construction. Report any differences between the water pressure and flows indicated on drawings and the actual pressure reading at the irrigation point of connection to the owners authorized representative.
15. Installer shall conduct final testing and adjustments to achieve design specifications prior to completion of the system and acceptance by the owner or owner's representative.
16. The installer shall provide property owners and users with post-construction documentation, including as-constructed drawings, recommended maintenance activities and schedules, operational schedule, design precipitation rates, instructions on adjusting the system to apply less water after the landscape is established, maintenance schedule, water source, water shut-off method, and the manufacturer's operation guide for the irrigation controller. To the extent feasible, similar information should be made available for subsequent property transfers.
17. Any changes and/or modifications to the water source shall require appropriate adjustments to the system design.
18. The contractor shall be responsible for providing all code required backflow preventers in addition to all permits as required by the governing agencies including water use permits, if applicable.
19. Plan prepared for code minimum requirements only. Contractor shall provide for a complete operating system.
20. System shall utilize an irrigation well as the water source. SFWMD Water Use permit by others. Final system design shall comply with parameters within the Water Use Permit.
GENERAL LANDSCAPE NOTES
1. THE QUALITY OF ALL PLANT MATERIAL WILL MEET THE STANDARDS
FOR FLORIDA GRADE NO.1 (or better), AS GOVERNED IN "GRADES AND
STANDARDS FOR NURSERY PLANTS".
2. ALL PLANTED TREES AND PALMS WILL HAVE A 3" DEEP SAUCER
CONSTRUCTED FROM THE TRUNK OF THE TREE OR PALM. MINIMUM
OF 5' DIAMETER.
3. ALL PLANTING BEDS SHALL BE COVERED WITH A 3" MINIMUM DEPTH
OF MULCH AND SHALL BE WEED FREE. MULCH SHALL BE GRADE B
OR BETTER. CONTRACTOR SHALL REMOVE ANY VEGETATIVE
GROWTH AND APPLY A PRE-EMERGENT WEED KILLER PER
SPECIFICATIONS PRIOR TO MULCHING.
4. NO CODE REQUIRED PLANTINGS SHALL BE INSTALLED IN
EASEMENTS.
5. ANY AND ALL EXOTIC VEGETATION INCLUDING: EARLEAF ACACIA,
WOMAN'S TONGUE, BISHOPWOOD, AUSTRAILIAN PINE,
CARROTWOOD, ROSEWOOD, AIR POTATO, MURRAY RED GUM,
WEEPING FIG, CUBAN LAUREL FIG, JAPANESE CLIMBING FERN, OLD
WORD CLIMBING FERN, MELALEUCA, DOWNY ROSE MYRTLE,
CHINESE TALLOW, BRAZILLIAN PEPPER, FLORIDA HOLLY, TROPICAL
SODA APPLE, JAVA PLUM, ROSE APPLE, CORK TREE AND WEDELIA,
ON THE PROPERTY SHALL BE COMPLETELY REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR. THE SITE SHALL BE
MAINTAINED FREE OF INVASIVE EXOTIC VEGETATION IN PERPETUITY.
6. TREES SHALL BE A MINIMUM OF 10' IN HEIGHT WITH A 2" CALIPER
MEASURED AT 1' ABOVE GROUND LEVEL WITH A FOUR FOOT
CANOPY.
7. REFER TO LANDSCAPE SPECIFICATIONS FOR ADDITIONAL
LANDSCAPE REQUIREMENTS.
8. REFER TO ENGINEERING PLANS FOR ADDITIONAL SPECIFICATIONS.
9. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR
FAMILIARIZING THEMSELVES WITH THE LOCATIONS OF ALL UTILITIES
AND ALL SITE CONDITIONS PRIOR TO THE START OF LANDSCAPE
INSTALLATION.
10. FERTILIZER SHALL BE IN ACCORDANCE WITH SPECIFICATIONS AND
LOCAL ORDINANCES.
11. IT SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR
TO FINE GRADE ALL PLANTING AND SODDING AREAS PRIOR TO
PLANT OR SOD INSTALLATION. CONTRACTOR SHALL OBTAIN OWNER
APPROVAL OF FINAL GRADES.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE TAKEOFFS.
PLANT LIST IS PROVIDED FOR REFERENCE ONLY.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR LANDSCAPE
MAINTENANCE UNTIL FINAL ACCEPTANCE AND WORK SHALL BE IN
COMPLIANCE WITH SPECIFICATIONS.
14. CONTRACTOR SHALL REMOVE ALL TAGS, TAPE AND NURSERY
CENTER SUPPORTS (EXCEPT STAKING GUYS) FROM ALL PLANTINGS
PRIOR TO FINAL ACCEPTANCE.
15. ALL AREAS OF THE SITE SHALL BE SODDED OR SEEDED IN
ACCORDANCE WITH PLANS.
16. THE REQUIRED PLANTINGS SHALL BE IRRIGATED IN ACCORDANCE
WITH CITY REQUIREMENTS.
17. THE PARKING LOTS SHALL BE SLEEVED FOR IRRIGATION BY THE
LANDSCAPE CONTRACTOR. COORDINATE WITH CIVIL ENGINEERING
PLANS.
18. ALL BASE ROCK SHALL BE REMOVED FROM LANDSCAPE PARKING
ISLANDS.
19. ALL CODE REQUIRED LANDSCAPING SHALL BE IRRIGATED WITH AN
AUTOMATIC IRRIGATION SYSTEM. SYSTEM TO INCLUDE A RAIN
SWITCH SHUT OFF AND ALL BACKFLOW DEVICES AS REQUIRED BY
LOCAL UTILITY PROVIDERS.
20. THE CONTRACTOR SHALL PROVIDE (PRESSURE COMPENSATING
SCREENS) AS NECESSARY TO REDUCE OR ELIMINATE OVERSPRAY
INTO STREETS, WALKS OR OTHER AREAS AS DICTATED BY THE
OWNER'S AUTHORIZED REPRESENTATIVE.
21. CONTRACTOR TO PROVIDE BACKFLOW DEVICE AND METERING AS
REQUIRED BY CITY OF FORT MYERS UTILITIES.
NOTE: EXISTING TREES SCHEDULED TO
REMAIN MEET MINIMUM SIZE
REQUIREMENTS FOR CODE PLANTINGS.
ANY TREE THAT IS REMOVED DUE TO
CONSTRUCTION SHALL BE REPLACED
PRIOR TO CERTIFICATION.
AutoCAD SHX Text
L.A. LICENSE: LC COOOO63
AutoCAD SHX Text
PROJECT INFORMATION:
EXISTING
WAREHOUSE #2
MATCHLINE
O V
E R
H E
A D
P O
W E
R L
IN
E
S
1 - BUC BU2
2 - SWI MA2
1 - QUE VI4
12 - SWI MA2
EXIST. TO REMAIN
EXIST. TO REMAIN
EXIST. TO REMAIN
EXIST. TO REMAIN
112 - Chr ic2
3 - Clu cfv
25 - Clu cfv
18 - Chr ic2
21 - For seg
6 - Chr ic2
18 - Pen adv
37 - Pen adv
(wB)
(bld)
(wB)
(bld)
(wB)
(wB)
(wB)
(wB)
(wB)
(wB)
(bld)
(9 EB, 17 G)
24 - CON SE2
93 - Chr ic2
(EB)
Michigan ave.
S
SS
EXISTING
WAREHOUSE #1
P A
LM
a v e
MATCHLINE
OVERHEAD POWER LINES
1 - BUC BU2
1 - BUC BU2
3 - ADO MRR
EXIST. TO REMAIN
EXIST. TO REMAIN
EXIST. TO REMAIN
18 - Chr ic2
16 - Chr ic2
6 - Pen adv
7 - Pen adv
23 - Chr ic2
49 - Pen adv
7 - Chr ic2
11 - Fic gr6
13 - Pen adv
2 - COC DIV
28 - Chr ic2
54 - Chr ic2
5 - CON SE2
3 - COC DIV
9 - Pen adv
36 - Chr ic2
40 - Ern lit
31 - For seg
4 - Ham mea
34 - Clu cfv
3 - CON SE2
10 - Pen adv
14 - Pen adv
(p) (p)
(24p, 12 eb)
(SB)
(SB)
(SB)
(wB)
(p)
(wB)
(wB)
(wB)
(wB)
(wB)
(wB)
(wB)
(wB)
(bld)
(bld)
(bld)
(bld)
(bld)
(bld)
(wB)
16 - Ham mea
10 - Fic gr6
9 - CON SE2
12 - Pen adv
17 - CON SE2
(10 EB, 7 G)
(3EB)
(EB)
70 - Chr ic2
PLAN SCALE REDUCED WHEN PRINTED 11x17
LANDSCAPE PLAN
L - 2-N
LANDSCAPE BETTERMENT PLAN
SCALE 1" = 20'
0' 10' 20' 40' 60'
INTERNAL UTILITY EASEMENT - NO TREES OR LARGE
SHRUBS SHALL BE PLANTED INSIDE THESE ZONES.
ALL TREES IN ISLANDS ARE LOCATED OUTSIDE OF
EASEMENT, MIN. 10' FROM BACK OF CURB
N SHEET TITLE:
SHEET NUMBER:
ISSUED DATE:
AND ASSOCIATES, INC.
LANDSCAPE ARCHITECTS
CONSULTANT:
DAVID M. JONES, JR.
AND PLANNERS
DESIGN PROFESSIONAL:
PROJECT NO.
PREPARED FOR:
REVISIONS:
PROJECT MJR:
FILE NAME:
DESIGNER:
CAD TECH:
CHECKED BY:
ISSUED FOR:
DMJA
GJD
GREGORY J. DISERIO
SEPT. 30, 2024
CALL 48 HOURS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811 Know what's BELOW.
Call before you dig.
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
2221 McGregor Blvd.
Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494
CFMPRF-N. PARCEL LS
C.F. M. - Parks and Recreation
North Parcel Addition
FORT MYERS, FL
PERMITTING
224036
Fort Myers, FL 1605 Hendry Street
Fort Myers, FL 33901 Phone: 239.418.0691
GJD
GJD
GREGORY J DISERIO, RLA
R.L.A. #: LA 0000840
STATE OF FLORIDA
OCT. 29, 2024 IRRIGATION
NOV. 15, 2024 EAST BUFFER
NOV. 20, 2024 SITE UPDATE
MARCH 11, 2025 SITE UPDATE
APRIL 28, 2025 ADDED FENCEJU
N E
, 2
D R
IV
E
C H
AN
G
E
JU
LY
3, BI
D
D O
C U
M
EN
T
PLANT SCHEDULE NOTES:
CONTRACTOR SHALL SOD ALL DISTURBED AREAS WITH BAHIA SOD.
ALL PLANTINGS (except as listed below) TO BE MULCHED WITH 3" DARK BROWN ORGANIC MULCH GRADE B OR BETTER. Cypress mulch prohibited.
CONTRACTOR RESPONSIBLE FOR VERIFICATION OF QUANTITIES AT TIME OF
BIDDING.
contractor responsible for sod and mulch quantities.
SYMBOL CODE QTY BOTANICAL / COMMON NAME SIZE
TREES
ADO MRR 3
Adonidia merrillii Manila Palm
EXISTING TO REMAIN
EXISTING TO REMAIN
COC DIV 5
Coccoloba diversifolia Pigeon Plum Native
Min. 2" Cal., 10` Ht., 4` Sprd.
CON SE2 58
Conocarpus erectus `Sericeus` Silver Buttonwood Native
Min. 2" Cal., 10` Ht., 4` Sprd.
EXISTING TREE TO BE REMOVED
QUE VI5 2
Quercus virginiana Southern Live Oak
EXISTING TO BE REMOVED
EXISTING TO BE REMOVED
SWI MA3 1
Swietenia mahagoni West Indian Mahogany EXISTING TO BE REMOVED
TAX DI4 6
Taxodium distichum Bald Cypress
EXISTING TO BE REMOVED
EXISTING TO BE REMOVED
EXISTING TREE TO REMAIN
BUC BU2 3
Bucida buceras Black Olive EXISTING TO REMAIN
QUE VI4 1
Quercus virginiana Southern Live Oak
NATIVE
EXISTING TO REMAIN
SWI MA2 14
Swietenia mahagoni West Indian Mahogany
NATIVE
EXISTING TO REMAIN
SHRUBS
Chr ic2 463 Chrysobalanus icaco Coco Plum Native
Min. 24" Ht., 3 Gallon
Clu cfv 62 Clusia flava Dwarf Clusia Non-Native
Min. 24" Ht., 3 Gallon
Fic gr6 21
Ficus microcarpa `Green Island` Green Island Ficus Non-Native
Min. 24" Ht., 3 Gallon
For seg 52 Forestiera segregata Florida Privet Native
24" Ht.
Ham mea 20 Hamelia patens var. glabra Compact Firebush Non-Native
Min. 24" Ht., 3 Gallon
Pen adv 175 Pennisetum advena `Rubrum` Red Fountain Grass
Min. 24" Ht., 3 Gallon
SYMBOL CODE QTY BOTANICAL / COMMON NAME SIZE SPACING
GROUND COVERS
Ern lit 40 Ernodea littoralis Golden Creeper Native
1 gal. 30" o.c.
PLANT SCHEDULE NORTH PARCEL
AutoCAD SHX Text
L.A. LICENSE: LC COOOO63
PROJECT INFORMATION:
HYDRANT
7.5' CLEARANCE (FRONT)
5' CLEARANCE (REAR)
PER NFPA 1-18.3.9.1 REQUIREMENTS
CLEAR AREAS FROM PLANTINGS
FRONT
REAR
MAINTAINED SHRUBS
LIMITS OF
HYDRANT CLEARANCE
NOT TO SCALE
MULCH, GRAVEL OR SOD
G SHRUB - MODIFIED SOIL
NOT TO SCALE pdet_shrub_modified soil
Notes:
1- Shrubs shall be of quality prescribed in the root observations detail and specifications.
2- See specifications for further requirements related to this detail.
Modified soil.
Depth varies. (See specifications for soil modification).
Root ball.
4" high x 8" wide round - topped soil berm above root ball surface shall be constructed around the root ball.
Berm shall begin at root ball periphery.
Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace shrub. Do not over compact. When the planting hole has been backfilled, pour water around the root ball to settle the soil.
4" layer of mulch.
No more than 1" of mulch on top of root ball. (See specifications for mulch).
Root ball rests on existing or recompacted soil.
Existing soil.
Finished grade.
Shrub.
SECTION VIEW
A TREE PLANTING DETAIL
NOT TO SCALE
Trunk caliper shall meet ANSI Z60 current edition for root ball size.
Modified soil.
Depth varies. (See soil preparation plan).
Finished grade.
Bottom of root ball rests on existing or recompacted soil.
Central leader. (See crown observations detail).
SECTION VIEW
Root ball modified as required.
Round-topped soil berm 4" high x 8" wide above root ball surface shall be constructed around the root ball. Berm shall begin at root ball periphery.
Top of root ball shall be flush with finished grade.
Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace tree. Do not over compact.
When the planting hole has been backfilled, pour water around the root ball to settle the soil.
4" layer of mulch.
No more than 1" of mulch on top of root ball. (See specifications for mulch).
Notes:
1- Trees shall be of quality prescribed in crown observations and root observations details and specifications.
2- See specifications for further requirements related to this detail.
Existing soil.
LANDSCAPE
DETAILS, NOTES &
SCHEDULE
L - 3-N
PROS-06 SPRAY HEAD WITH PRO-FLEX TUBING
3" = 1'-0"
FINISH GRADE
MODEL PROS-06 SPRAY HEAD
SWING JOINT:
HUNTER 'PRO-FLEX' TUBING,
HSBE-050 ELBOWS (2), &
MARLEX STREET ELBOW (1)
LATERAL TEE OR ELL
LATERAL PIPE
FX-IR-HUNT-SPRA-32
GENERAL IRRIGATION NOTES
1. All mainline and lateral line piping and control wires under paving shall be installed in separate sleeves. main and lateral line sleeves shall be a minimum of twice (2x) the diameter of the pipe to be sleeved. Control wire sleeves shall be sufficient size for the required number of wires under paving.
2. Pipe sizes shall conform to those shown on the drawings. No substitutes of smaller pipe sizes shall be permitted but substitutions of larger sizes may be approved. All damaged and rejected pipe shall be removed from the site at the time of said rejection.
3. All sprinkler heads shall be set perpendicular to finished grade unless otherwise specified.
4. The irrigation contractor shall flush and adjust all sprinkler heads and valves for optimum coverage with minimal overspray onto walks, streets, walls, etc.
5. Irrigation heads shall be a minimum of 12" from buildings.
6. This design is diagrammatic. All piping, valves, etc. shown within paved areas are for design clarification only and shall be installed in planting areas whenever possible. The contractor shall locate all valves in shrub areas where possible.
7. It is the responsibility of the irrigation contractor to familiarize himself with all grade differences, location of walls, structures and utilities. The irrigation contractor shall repair or replace all items damaged by his work. He shall coordinate his work with other contractors for the location and installation of pipe sleeves through walls, under roadways and paving, etc.
8. Do not willfully install the sprinkler system as shown on the drawings when it is obvious in the field that unknown obstructions, grade differences, water levels or differences in the area dimensions exist that might not have been considered in the engineering. Such obstructions or differences should be brought to the attention of owners representative. In the event this notification is not performed, the irrigation contractor shall assume full responsibility for any revisions necessary.
9. All sprinkler equipment not otherwise detailed or specified shall be installed as per manufacturer's recommendations and specifications.
10. The contractor shall provide (Pressure Compensating Screens) as necessary to reduce or eliminate over spray into streets, walks or other areas as dictated by the owner's authorized representative.
11. All remote control valves, gate valves, quick couplers and control wire splices shall be installed in approved valve boxes with locking covers. All shall be marked indicating controller and station numbers for control valve.
12. Contractor to provide the Owner with a complete irrigation design in compliance with Owners program.
All required plantings shall be irrigated.
13. Irrigation system shall be designed for complete coverage. Verify with owner limits of irrigation for sod prior to bidding.
14. The sprinkler system to be based on a minimum operating pressure of 40 PSI. The irrigation contractor shall verify water pressures, flows, elevations, and other requirements prior to construction.
Report any differences between the water pressure and flows indicated on drawings and the actual pressure reading at the irrigation point of connection to the owners authorized representative.
15. Installer shall conduct final testing and adjustments to achieve design specifications prior to completion of the system and acceptance by the owner or owner's representative.
16. The installer shall provide property owners and users with post-construction documentation, including as-constructed drawings, recommended maintenance activities and schedules, operational schedule, design precipitation rates, instructions on adjusting the system to apply less water after the landscape is established, maintenance schedule, water source, water shut-off method, and the manufacturer's operation guide for the irrigation controller. To the extent feasible, similar information should be made available for subsequent property transfers.
17. Any changes and/or modifications to the water source shall require appropriate adjustments to the system design.
18. The contractor shall be responsible for providing all code required backflow preventers in addition to all permits as required by the governing agencies including water use permits, if applicable.
19. Plan prepared for code minimum requirements only. Contractor shall provide for a complete operating system.
20. System shall utilize an irrigation meter and backflow. Refer to Civil plans.
PLANTING DETAILS
SHEET TITLE:
SHEET NUMBER:
ISSUED DATE:
AND ASSOCIATES, INC.
LANDSCAPE ARCHITECTS
CONSULTANT:
DAVID M. JONES, JR.
AND PLANNERS
DESIGN PROFESSIONAL:
PROJECT NO.
PREPARED FOR:
REVISIONS:
PROJECT MJR:
FILE NAME:
DESIGNER:
CAD TECH:
CHECKED BY:
ISSUED FOR:
DMJA
GJD
GREGORY J. DISERIO
SEPT. 30, 2024
CALL 48 HOURS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811 Know what's BELOW.
Call before you dig.
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
2221 McGregor Blvd.
Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494
CFMPRF-N. PARCEL LS
C.F. M. - Parks and Recreation
North Parcel Addition
FORT MYERS, FL
PERMITTING
224036
Fort Myers, FL 1605 Hendry Street
Fort Myers, FL 33901 Phone: 239.418.0691
GJD
GJD
GREGORY J DISERIO, RLA
R.L.A. #: LA 0000840
STATE OF FLORIDA
OCT. 29, 2024 IRRIGATION
NOV. 15, 2024 EAST BUFFER
NOV. 20, 2024 SITE UPDATE
MARCH 11, 2025 SITE UPDATE
APRIL 28, 2025 ADDED FENCEJU
N E
, 2
D R
IV
E
C H
AN
G
E
JU
LY
3, BI
D
D O
C U
M
EN
T
GENERAL LANDSCAPE NOTES
1. THE QUALITY OF ALL PLANT MATERIAL WILL MEET THE STANDARDS FOR FLORIDA GRADE
NO.1 (or better), AS GOVERNED IN "GRADES AND STANDARDS FOR NURSERY PLANTS".
2. ALL PLANTED TREES AND PALMS WILL HAVE A 3" DEEP SAUCER CONSTRUCTED FROM THE
TRUNK OF THE TREE OR PALM. MINIMUM OF 5' DIAMETER.
3. ALL PLANTING BEDS SHALL BE COVERED WITH A 3" MINIMUM DEPTH OF MULCH AND
SHALL BE WEED FREE. MULCH SHALL BE GRADE B OR BETTER. CONTRACTOR SHALL
REMOVE ANY VEGETATIVE GROWTH AND APPLY A PRE-EMERGENT WEED KILLER PER
SPECIFICATIONS PRIOR TO MULCHING.
4. NO CODE REQUIRED PLANTINGS SHALL BE INSTALLED IN EASEMENTS.
5. ANY AND ALL EXOTIC VEGETATION INCLUDING: EARLEAF ACACIA, WOMAN'S TONGUE,
BISHOPWOOD, AUSTRAILIAN PINE, CARROTWOOD, ROSEWOOD, AIR POTATO, MURRAY
RED GUM, WEEPING FIG, CUBAN LAUREL FIG, JAPANESE CLIMBING FERN, OLD WORD
CLIMBING FERN, MELALEUCA, DOWNY ROSE MYRTLE, CHINESE TALLOW, BRAZILLIAN
PEPPER, FLORIDA HOLLY, TROPICAL SODA APPLE, JAVA PLUM, ROSE APPLE, CORK TREE
AND WEDELIA, ON THE PROPERTY SHALL BE COMPLETELY REMOVED AND DISPOSED OF
OFF SITE BY THE CONTRACTOR. THE SITE SHALL BE MAINTAINED FREE OF INVASIVE
EXOTIC VEGETATION IN PERPETUITY.
6. TREES SHALL BE A MINIMUM OF 10' IN HEIGHT WITH A 2" CALIPER MEASURED AT 1' ABOVE
GROUND LEVEL WITH A FOUR FOOT CANOPY.
7. REFER TO LANDSCAPE SPECIFICATIONS FOR ADDITIONAL LANDSCAPE REQUIREMENTS.
8. REFER TO ENGINEERING PLANS FOR ADDITIONAL SPECIFICATIONS.
9. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES
WITH THE LOCATIONS OF ALL UTILITIES AND ALL SITE CONDITIONS PRIOR TO THE START
OF LANDSCAPE INSTALLATION.
10. FERTILIZER SHALL BE IN ACCORDANCE WITH SPECIFICATIONS AND LOCAL ORDINANCES.
11. IT SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TO FINE GRADE ALL
PLANTING AND SODDING AREAS PRIOR TO PLANT OR SOD INSTALLATION. CONTRACTOR
SHALL OBTAIN OWNER APPROVAL OF FINAL GRADES.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE TAKEOFFS. PLANT LIST IS
PROVIDED FOR REFERENCE ONLY.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR LANDSCAPE MAINTENANCE UNTIL FINAL
ACCEPTANCE AND WORK SHALL BE IN COMPLIANCE WITH SPECIFICATIONS.
14. CONTRACTOR SHALL REMOVE ALL TAGS, TAPE AND NURSERY CENTER SUPPORTS
(EXCEPT STAKING GUYS) FROM ALL PLANTINGS PRIOR TO FINAL ACCEPTANCE.
15. ALL AREAS OF THE SITE SHALL BE SODDED OR SEEDED IN ACCORDANCE WITH PLANS.
16. THE REQUIRED PLANTINGS SHALL BE IRRIGATED IN ACCORDANCE WITH CITY
REQUIREMENTS.
17. THE PARKING LOTS SHALL BE SLEEVED FOR IRRIGATION BY THE LANDSCAPE
CONTRACTOR. COORDINATE WITH CIVIL ENGINEERING PLANS.
18. ALL BASE ROCK SHALL BE REMOVED FROM LANDSCAPE PARKING ISLANDS.
19. ALL CODE REQUIRED LANDSCAPING SHALL BE IRRIGATED WITH AN AUTOMATIC
IRRIGATION SYSTEM. SYSTEM TO INCLUDE A RAIN SWITCH SHUT OFF AND ALL BACKFLOW
DEVICES AS REQUIRED BY LOCAL UTILITY PROVIDERS.
20. THE CONTRACTOR SHALL PROVIDE (PRESSURE COMPENSATING SCREENS) AS
NECESSARY TO REDUCE OR ELIMINATE OVERSPRAY INTO STREETS, WALKS OR OTHER
AREAS AS DICTATED BY THE OWNER'S AUTHORIZED REPRESENTATIVE.
21. CONTRACTOR TO PROVIDE BACKFLOW DEVICE AND METERING AS REQUIRED BY CITY OF
FORT MYERS UTILITIES.
AutoCAD SHX Text R
AutoCAD SHX Text
L.A. LICENSE: LC COOOO63
AutoCAD SHX Text
PROJECT INFORMATION:
AutoCAD SHX Text R
AutoCAD SHX Text
IRRIGATION DETAIL
AutoCAD SHX Text
SCALE: 1" = 1'-0"
AutoCAD SHX Text
XX
AutoCAD SHX Text
ICV GLOBE VALVE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REMOTE CONTROL VALVE MODEL ICV-XXXG ACCU-SYNC-ADJ
AutoCAD SHX Text
3/4" MINUS WASHED GRAVEL
AutoCAD SHX Text
MAIN LINE PIPE & FITTINGS
AutoCAD SHX Text
SCH 80 T.O.E. NIPPLE
AutoCAD SHX Text
BRICK SUPPORTS (4)
AutoCAD SHX Text
WATERPROOF CONNECTORS (2)
AutoCAD SHX Text
18-24" COILED WIRE
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
STANDARD VALVE BOX
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PVC SLIP UNIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PVC SLIP UNIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING
WAREHOUSE #2
MATCHLINE
O V
E R
H E
A D
P O
W E
R L
IN
E
S
1"
1" 1"
1"
1"
2"
1"
1"
1"
1"
2"
1"
1"
2"
21.5112"
13.2112"
23.3112"
1"
2"
16.9112"
2"
2"
1"
112"
1"
1"
2"
15.0112"
1"
2"
2"
2"
16.3112"
1" 1"
2"
Michigan ave.
S
SS
EXISTING
WAREHOUSE #1
P A
LM
a v e
MATCHLINE
OVERHEAD POWER LINES
1"
1"
2"
1"
1"
2"
1"
1"
2"1" 1"
2"
1"
2"
1"11 2"
1"
2"
1"1
2"
1"
1 2"
C
RS
M
13.21 2"
23.3112"
15.9112"
19.1112"
18.5112"
16.72"
19.7112"
1"
2"
2"
20.8112"
16.9112"
1"
2"
1"
2"
1" 12
16.3112"
1"
1"
2"
2"
2"
14.9112"
1"
2"
1"
PLAN SCALE REDUCED WHEN PRINTED 11x17
IRRIGATION
PLAN
IR-1-N
IRRIGATION PLAN
SCALE 1" = 20'
0' 10' 20' 40' 60'
INTERNAL UTILITY EASEMENT - NO TREES OR LARGE
SHRUBS SHALL BE PLANTED INSIDE THESE ZONES.
ALL TREES IN ISLANDS ARE LOCATED OUTSIDE OF
EASEMENT, MIN. 10' FROM BACK OF CURB
N SHEET TITLE:
SHEET NUMBER:
ISSUED DATE:
AND ASSOCIATES, INC.
LANDSCAPE ARCHITECTS
CONSULTANT:
DAVID M. JONES, JR.
AND PLANNERS
DESIGN PROFESSIONAL:
PROJECT NO.
PREPARED FOR:
REVISIONS:
PROJECT MJR:
FILE NAME:
DESIGNER:
CAD TECH:
CHECKED BY:
ISSUED FOR:
DMJA
GJD
GREGORY J. DISERIO
SEPT. 30, 2024
CALL 48 HOURS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811 Know what's BELOW.
Call before you dig.
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
2221 McGregor Blvd.
Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494
CFMPRF-N. PARCEL LS
C.F. M. - Parks and Recreation
North Parcel Addition
FORT MYERS, FL
PERMITTING
224036
Fort Myers, FL 1605 Hendry Street
Fort Myers, FL 33901 Phone: 239.418.0691
GJD
GJD
GREGORY J DISERIO, RLA
R.L.A. #: LA 0000840
STATE OF FLORIDA
OCT. 29, 2024 IRRIGATION
NOV. 15, 2024 EAST BUFFER
NOV. 20, 2024 SITE UPDATE
MARCH 11, 2025 SITE UPDATE
APRIL 28, 2025 ADDED FENCEJU
N E
, 2
D R
IV
E
C H
AN
G
E
JU
LY
3, BI
D
D O
C U
M
EN
T
3/4"
2-1/2"
1-1/4" 1-1/2"
SIZE
51-70 31-50 2"
GPM
Not Used
14-30 Not Used 113 1"
S C
H E
D U
LE
Flows shall maintain velocities of less than 5 feet per second
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY ARC GPM RADIUS
Hunter PROS-06-PRS40 RCS-515 Shrub Spray, 40 psi regulated 6in. pop-up
1 RCS 0.65 5'x15'
Hunter PROS-06-PRS40 SS-530 Shrub Spray, 40 psi regulated 6in. pop-up
48 SST 1.3 5'x30'
Hunter PROS-06-PRS40 08H Shrub Spray, 40 psi regulated 6in. pop-up
2 180 0.47 8'
Hunter PROS-06-PRS40 10H Shrub Spray, 40 psi regulated 6in. pop-up
90 180 0.88 10'
Hunter PROS-06-PRS40 10Q Shrub Spray, 40 psi regulated 6in. pop-up
2 90 0.42 10'
Hunter PROS-06-PRS40 15H Shrub Spray, 40 psi regulated 6in. pop-up
36 180 1.86 15'
Hunter PROS-06-PRS40 15Q Shrub Spray, 40 psi regulated 6in. pop-up
6 90 0.97 15'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Hunter ICV-G 1-1/2" 1in., 1-1/2in., 2in., and 3in. Plastic Electric Remote Control Valves, Globe Configuration, with NPT Threaded Inlet/Outlet, for Commercial/Municipal Use.
Hunter ICV-G 2" 1in., 1-1/2in., 2in., and 3in. Plastic Electric Remote Control Valves, Globe Configuration, with NPT Threaded Inlet/Outlet, for Commercial/Municipal Use.
Hunter I2C-1600-M 16 Station Outdoor Modular Controller. With one ICM-800 Module. Commercial Use.
Metal Cabinet.
Hunter MINI-CLIK Rain Sensor, mount as noted
Water Meter 1-1/2"
IRRIGATION METER AND BACKFLOW PER
ENGINERING PLANS
Irrigation Lateral Line: PVC Schedule 40 1" 2,086 lf Irrigation Lateral Line: PVC Schedule 40 1 1/2" 270.0 lf
Irrigation Mainline: PVC Schedule 40 2" 802.6 lf
Irrigation Mainline: PVC Schedule 40 51.0 lf
Irrigation Mainline: PVC Schedule 40 2" 802.6 lf
Irrigation Mainline: PVC Schedule 40 51.0 lf
Irrigation Mainline: PVC Schedule 40 2" 802.6 lf
Irrigation Mainline: PVC Schedule 40 51.0 lf
Irrigation Mainline: PVC Schedule 40 2" 802.6 lf
Irrigation Mainline: PVC Schedule 40 2" 802.6 lf
Pipe Sleeve: PVC Class 200 SDR 21 81.7 lf
C
RS
M
IRRIGATION SCHEDULE NORTH PARCEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text open cut pavement and repair per civil plans
AutoCAD SHX Text open cut pavement and repair per civil plans
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
L.A. LICENSE: LC COOOO63
AutoCAD SHX Text
PROJECT INFORMATION:
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Valve Number
AutoCAD SHX Text Valve Flow
AutoCAD SHX Text Valve Size
AutoCAD SHX Text Valve Callout
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| CFMPRF-North Parcel_LS7.13.25-L-1 |
| CFMPRF-North Parcel_LS7.13.25-L2 |
| CFMPRF-North Parcel_LS7.13.25-L-3 |
| CFMPRF-North Parcel_LS7.13.25-ir1 |
| 2025-07-23T16:21:15-0400 | |
| Gregory J. Diserio, RLA |
| 2025-07-23T16:21:37-0400 | |
| Gregory J. Diserio, RLA |
| 2025-07-23T16:21:56-0400 | |
| Gregory J. Diserio, RLA |
| 2025-07-23T16:22:11-0400 | |
| Gregory J. Diserio, RLA |
File details come from the government source that posted it. Updated .