CFM_Parks_and_Rec_-_Landscape_Plans_-_South_Parcel.pdf

PDF 2 MB Posted

Attached to
Michigan Avenue Warehouse Renovation
Solicitation number
ITB 25-098
Issued by
Lee County, Fruitville CDP, Florida

About this file

These landscape and irrigation plans detail the Parks and Recreation Facility Parking Addition project located in Fort Myers, Florida, prepared by David M. Jones Jr. and Associates, Inc. The site is a commercial parking lot spanning 34,193 square feet (~0.78 acres) with comprehensive landscape design requirements including open space, tree placement, buffer zones, and irrigation specifications. The project includes planting 6 Glossy Shower Trees, 27 Native Buttonwood trees, 8 Native Southern Live Oak trees, 12 Native Florida Royal Palm trees, and various shrubs like Native Coco Plum, Autograph Tree, and Compact Firebush, totaling approximately 321 shrubs and 57 trees.

The landscape plan meticulously addresses local landscaping codes, requiring 20% open space (6,839 sf), 10 on-site trees, internal parking landscape areas, and specific buffer requirements for adjacent rights-of-way on Seaboard Street and Michigan Avenue. The irrigation system will utilize Hunter brand equipment, including 12 and 15 series shrub sprays, flood bubblers, and a 1-1/2" water meter. The design includes specific notes about removing exotic vegetation, maintaining landscape areas, and complying with local utility and permitting requirements. The project documents were initially issued on November 12, 2024, with subsequent updates on March 11 and March 28, 2025, and a final RAI response on June 11, 2025.

View the file

Other files

File Type Posted
Michigan_Avenue_Warehouse_Renovation_(Addendum_#19_Revision).pdf PDF
Michigan_Avenue_Warehouse_Renovation_(Addendum_#10_Revision).pdf PDF
DIVISION_22_-_PLUMBING.pdf PDF
DIVISIONS_27_&_28_-_SECURITY_&_COMMS.pdf PDF
CoFM_Warehouse_Conversion_Parks_and_Records_Dept_Arch_Spec_Binder.pdf PDF
CFM_Parks_and_Rec_-_Civil_Plans_-_North_Parcel.pdf PDF
2024-118_-_Combined_Plumbing_-_S&S.pdf PDF
2024-118_-_CoFM_Warehouse_-_Combined_Electrical.pdf PDF
2024-118_-_Combined_Mechanical_-_S&S.pdf PDF
20250619_-_Warehouse_Convert_to_Parks_&_Rec_Department_100%_CD_KMW.pdf PDF
CFM_Parks_and_Rec_-_Tech_Specifications.pdf PDF
2025.06.19-_Exist_Warehouse_to_Parks_Rec_-_Structural_Permit_Set_SS.pdf PDF
DIVISON_26_-_ELECTRICAL.pdf PDF
DIVISON_21_-_FIRE_PROTECTION.pdf PDF
CFM_Parks_and_Rec_-_Civil_Plans_-_South_Parcel.pdf PDF
2024-118_-_Combined_Fire_Protection_-_S&S.pdf PDF
CFM_Parks_and_Rec_-_Landscape_Plans_-_North_Parcel.pdf PDF
DIVISION_23_-_HVAC.pdf PDF
SRF_SupplementaryConditions_EM_Contract_(August_2022).pdf PDF
SRF_SupplementaryConditions_Construction_Contract_(August_2022).pdf PDF
FHWA-1273_(10_23)_.pdf PDF
Notice_of_Award.docx DOCX document
2_CFR_Part_200_app_II_(up_to_date_as_of_4-28-2025).pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S S

' S

IG

H

T

TR

IA

N

G

LE

' S

IG

H

T

TR

IA

N

G

LE

Michigan ave.

se a b o a r d s t.

P A

LM

a v e

2"

112"

2"

SS

SITE PLAN AND

CALCULATIONS

L - 1-S

SITE LANDSCAPE CALCULATIONS SCALE 1" = 20'

0' 10' 20' 40' 60'

Landscape Calculations Site Data( Work Area) Site Use: Commercial Parking Site Area: 34,193 S.F. (~0.78 AC) F.L.U.M.: Commercial

Open Space Requirements Commercial developments require 20% open space 34,193 S.F. Development x 20% = 6,839 sf required Open space provided = 20,960 S.F. provided per hatching shown.

General On-Site Tree Requirements Commercial developments require 1 tree per 5,000 sf.

34,193 s.f. / 3,500 = 10 Tree credits required and 10 tree credits provided, labeled as (G) or (G+).

Internal Parking Landscape Requirement Internal landscape areas of 10% of the parking area is required.

21,326 s.f. x10% =2,133 s.f. REQUIRED and 3,250 s.f.

PROVIDED PER HATCHING SHOWN.

Per Sec 138-41(3), Curbed parking islands, peninsulas and medians Require 1 Tree and 10 Shrubs per 200 s.f.

2,133 s.f. Parking Islands exist /200 s.f. = 11 Trees Required and 11 Provided, labeled as (P) Parking.

2,133 s.f. Parking Islands exist /200 s.f. x 10 Shrubs = 107 Shrubs Required and 108 Provided, labeled as (P).

Building Perimeter Planting A required 10% of the proposed gross footprint must be provided for the building perimeter planting area.

Abutting all side excluding loading area, with 5' width and maximum of 10% of total area as turf.

NOT APPLICABLE

Buffer Requirements

EAST BUFFER

COMMERCIAL - R.O.W. (Seaboard St.)

15' Type 'B' Required;

4 Trees and 66 shrubs per 100 lf.

143'/100 x 4 = 6 Trees Required and 6 Provided, labeled as (E.B.).

143'/100 x 66 = 95 Shrubs Required and 95 Provided, labeled as

(E.B.).

WEST BUFFER:

COMMERCIAL - COMMERCIAL

No Buffer Required

NORTH BUFFER:

COMMERCIAL - R.O.W. (Michigan Ave.)

15' Type 'B' Required;

4 Trees and 66 shrubs per 100 lf.

245'/100 x 4 = 10 Trees Required and 10 Provided, labeled as (N.B.).

245'/100 x 66 = 162 Shrubs Required and 162 Provided, labeled as (N.B.).

SOUTH BUFFER:

COMMERCIAL - COMMERCIAL

No Buffer Required

PLAN SCALE REDUCED WHEN PRINTED 11x17

INTERNAL UTILITY EASEMENT - NO TREES OR LARGE

SHRUBS SHALL BE PLANTED INSIDE THESE ZONES.

ALL TREES IN ISLANDS ARE LOCATED OUTSIDE OF

EASEMENT, MIN. 10' FROM BACK OF CURB

N

SHEET TITLE:

SHEET NUMBER:

ISSUED DATE:

AND ASSOCIATES, INC.

LANDSCAPE ARCHITECTS

CONSULTANT:

DAVID M. JONES, JR.

AND PLANNERS

DESIGN PROFESSIONAL:

PROJECT NO.

PREPARED FOR:

REVISIONS:

PROJECT MJR:

FILE NAME:

DESIGNER:

CAD TECH:

CHECKED BY:

ISSUED FOR:

DMJA

GREGORY J DISERIO

NOV. 12, 2024

CALL 48 HOURS

BEFORE YOU DIG

IT'S THE LAW!

DIAL 811 Know what's BELOW.

Call before you dig.

SUNSHINE STATE ONE CALL OF FLORIDA, INC.

2221 McGregor Blvd.

Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494

CFMPRF-Parking_LS

C.F. M. - Parks and Recreation Facility Parking

Addition

FORT MYERS, FL

SITE PERMITTING

224036

Fort Myers, FL 1605 Hendry Street

Fort Myers, FL 33901 Phone: 239.418.0691

GJD

GREGORY J. DISERIO, RLA

R.L.A. #: LA 0000840

STATE OF FLORIDA

GJD

GJD

MARCH 11, 2025 SITE UPDATE

MARCH 28, 2025 PLANT CHANGE

JUNE 11, 2025 RAI RESPONSE

DO NOT PLANT

TREES IN BOTTOM

OF SWALES

AutoCAD SHX Text

L.A. LICENSE: LC COOOO63

AutoCAD SHX Text

PROJECT INFORMATION:

' S

IG

H

T

TR

IA

N

G

LE

' S

IG

H

T

TR

IA

N

G

LE

Michigan ave.

se a b o a r d s t.

P A

LM

a v e

2 - TAB NTR

2 - TAB NTR

5 - QUE VIR

6 - CAS ETR

3 - QUE VIR

27 - CON ERE

2 - TAB NTR

12 - ROY ELA

24 - Ham mea 45 - Ern lit

35 - Ern lit

11 - Ham mea12 - Ern lit

57 - Chr ic2

39 - Ern lit 37 - Ern lit

9 - Ham mea 25 - Ern lit

28 - Clu aut 21 - Ham mea13 - Ixo red

11 - Ham mea

26 - Ham mea

18 - Ern lit 55 - Clu au2

124 - Spa bak

17 - Ixo red

17 - Chr ic2

142 - Chr ic2

10 - Ham mea

23 - Chr ic2

9 - Chr ic2

21 - Chr ic2

37 - Myr fra

8 - CON SE2

11 - CON SE2

1 - TAB NTR

1 - TAB NTR 6 - CON SE2

117 - Clu au2

16 - Clu au2

31 - Chr ic2

21 - Chr ic2

31 - Tri dac

30 - Ern lit

SS

PLAN SCALE REDUCED WHEN PRINTED 11x17

LANDSCAPE PLAN

L - 2-S

LANDSCAPE BETTERMENT PLAN

SCALE 1" = 20'

0' 10' 20' 40' 60'

INTERNAL UTILITY EASEMENT - NO TREES OR LARGE

SHRUBS SHALL BE PLANTED INSIDE THESE ZONES.

ALL TREES IN ISLANDS ARE LOCATED OUTSIDE OF

EASEMENT, MIN. 10' FROM BACK OF CURB

N

SHEET TITLE:

SHEET NUMBER:

ISSUED DATE:

AND ASSOCIATES, INC.

LANDSCAPE ARCHITECTS

CONSULTANT:

DAVID M. JONES, JR.

AND PLANNERS

DESIGN PROFESSIONAL:

PROJECT NO.

PREPARED FOR:

REVISIONS:

PROJECT MJR:

FILE NAME:

DESIGNER:

CAD TECH:

CHECKED BY:

ISSUED FOR:

DMJA

GREGORY J DISERIO

NOV. 12, 2024

CALL 48 HOURS

BEFORE YOU DIG

IT'S THE LAW!

DIAL 811 Know what's BELOW.

Call before you dig.

SUNSHINE STATE ONE CALL OF FLORIDA, INC.

2221 McGregor Blvd.

Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494

CFMPRF-Parking_LS

C.F. M. - Parks and Recreation Facility Parking

Addition

FORT MYERS, FL

SITE PERMITTING

224036

Fort Myers, FL 1605 Hendry Street

Fort Myers, FL 33901 Phone: 239.418.0691

GJD

GREGORY J. DISERIO, RLA

R.L.A. #: LA 0000840

STATE OF FLORIDA

GJD

GJD

MARCH 11, 2025 SITE UPDATE

MARCH 28, 2025 PLANT CHANGE

JUNE 11, 2025 RAI RESPONSE

PLANT SCHEDULE NOTES:

CONTRACTOR SHALL SOD ALL DISTURBED AREAS WITH BAHIA SOD.

ALL PLANTINGS (except as listed below) TO BE MULCHED WITH 3" DARK BROWN ORGANIC MULCH GRADE B OR BETTER. Cypress mulch prohibited.

CONTRACTOR RESPONSIBLE FOR VERIFICATION OF QUANTITIES AT TIME OF

BIDDING.

contractor responsible for sod and mulch quantities.

SYMBOL CODE QTY BOTANICAL NAME COMMON NAME SIZE

TREES

CAS ETR 6 Cassia surattensis Glossy Shower Tree 2" Cal., 10` Ht., 4` Sprd.; Standard

CON ERE 27 Conocarpus erectus Native

Buttonwood Min. 2" Cal., 10` Ht., 4` Sprd.

CON SE2 25 Conocarpus erectus `Sericeus` Native Silver Buttonwood Min. 2" Cal., 10` Ht., 4` Sprd.

QUE VIR 8 Quercus virginiana Native Southern Live Oak 16` HT,3.5" CAL. 6`-7` SPR.

ROY ELA 12

Roystonea elata Native

Florida Royal Palm 12`-14` CT

TAB NTR 8 Tabebuia heptaphylla Pink Trumpet Tree 2" Cal., 10` Ht., 4` Sprd.; Standard

SHRUBS

Chr ic2 321 Chrysobalanus icaco Native

Coco Plum Min. 24" Ht., 3 Gallon

Clu au2 188 Clusia rosea Autograph Tree 3 gal., 24" ht

Clu aut 28 Clusia rosea Native Enhanced Buffer

Autograph Tree Min. 5` Ht., 10 Gal., 3` Sprd.

Ham mea 112 Hamelia patens var. glabra Non-Native

Compact Firebush Min. 24" Ht., 3 Gallon

Ixo red 30 Ixora coccinea Non-Native Red Ixora Min. 24" Ht., 3 Gallon

Myr fra 37 Myrcianthes fragrans Native

Simpson`s Stopper 48" Ht., Spa bak 124 Spartina bakeri Native

Sand Cordgrass Min. 24" Ht., 3 Gallon

SYMBOL CODE QTY BOTANICAL NAME COMMON NAME SIZE SPACING

GROUND COVERS

Ern lit 241 Ernodea littoralis Native

Golden Creeper 1 gal. 30" o.c.

PLANT SCHEDULE

DO NOT PLANT

TREES IN BOTTOM

OF SWALES

AutoCAD SHX Text

L.A. LICENSE: LC COOOO63

PROJECT INFORMATION:

HYDRANT

7.5' CLEARANCE (FRONT)

5' CLEARANCE (REAR)

PER NFPA 1-18.3.9.1 REQUIREMENTS

CLEAR AREAS FROM PLANTINGS

FRONT

REAR

MAINTAINED SHRUBS

LIMITS OF

HYDRANT CLEARANCE

NOT TO SCALE

MULCH, GRAVEL OR SOD

G SHRUB - MODIFIED SOIL

NOT TO SCALE pdet_shrub_modified soil

Notes:

1- Shrubs shall be of quality prescribed in the root observations detail and specifications.

2- See specifications for further requirements related to this detail.

Modified soil.

Depth varies. (See specifications for soil modification).

Root ball.

4" high x 8" wide round - topped soil berm above root ball surface shall be constructed around the root ball.

Berm shall begin at root ball periphery.

Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace shrub. Do not over compact. When the planting hole has been backfilled, pour water around the root ball to settle the soil.

4" layer of mulch.

No more than 1" of mulch on top of root ball. (See specifications for mulch).

Root ball rests on existing or recompacted soil.

Existing soil.

Finished grade.

Shrub.

SECTION VIEW

A TREE PLANTING DETAIL

NOT TO SCALE

Trunk caliper shall meet ANSI Z60 current edition for root ball size.

Modified soil.

Depth varies. (See soil preparation plan).

Finished grade.

Bottom of root ball rests on existing or recompacted soil.

Central leader. (See crown observations detail).

SECTION VIEW

Root ball modified as required.

Round-topped soil berm 4" high x 8" wide above root ball surface shall be constructed around the root ball. Berm shall begin at root ball periphery.

Top of root ball shall be flush with finished grade.

Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace tree. Do not over compact.

When the planting hole has been backfilled, pour water around the root ball to settle the soil.

4" layer of mulch.

No more than 1" of mulch on top of root ball. (See specifications for mulch).

Notes:

1- Trees shall be of quality prescribed in crown observations and root observations details and specifications.

2- See specifications for further requirements related to this detail.

Existing soil.

LANDSCAPE

DETAILS, NOTES &

SCHEDULE

L - 3-S

GENERAL IRRIGATION NOTES

1. All mainline and lateral line piping and control wires under paving shall be installed in separate sleeves. main and lateral line sleeves shall be a minimum of twice (2x) the diameter of the pipe to be sleeved. Control wire sleeves shall be sufficient size for the required number of wires under paving.

2. Pipe sizes shall conform to those shown on the drawings. No substitutes of smaller pipe sizes shall be permitted but substitutions of larger sizes may be approved. All damaged and rejected pipe shall be removed from the site at the time of said rejection.

3. All sprinkler heads shall be set perpendicular to finished grade unless otherwise specified.

4. The irrigation contractor shall flush and adjust all sprinkler heads and valves for optimum coverage with minimal overspray onto walks, streets, walls, etc.

5. Irrigation heads shall be a minimum of 12" from buildings.

6. This design is diagrammatic. All piping, valves, etc. shown within paved areas are for design clarification only and shall be installed in planting areas whenever possible. The contractor shall locate all valves in shrub areas where possible.

7. It is the responsibility of the irrigation contractor to familiarize himself with all grade differences, location of walls, structures and utilities. The irrigation contractor shall repair or replace all items damaged by his work. He shall coordinate his work with other contractors for the location and installation of pipe sleeves through walls, under roadways and paving, etc.

8. Do not willfully install the sprinkler system as shown on the drawings when it is obvious in the field that unknown obstructions, grade differences, water levels or differences in the area dimensions exist that might not have been considered in the engineering. Such obstructions or differences should be brought to the attention of owners representative. In the event this notification is not performed, the irrigation contractor shall assume full responsibility for any revisions necessary.

9. All sprinkler equipment not otherwise detailed or specified shall be installed as per manufacturer's recommendations and specifications.

10. The contractor shall provide (Pressure Compensating Screens) as necessary to reduce or eliminate over spray into streets, walks or other areas as dictated by the owner's authorized representative.

11. All remote control valves, gate valves, quick couplers and control wire splices shall be installed in approved valve boxes with locking covers. All shall be marked indicating controller and station numbers for control valve.

12. Contractor to provide the Owner with a complete irrigation design in compliance with Owners program.

All required plantings shall be irrigated.

13. Irrigation system shall be designed for complete coverage. Verify with owner limits of irrigation for sod prior to bidding.

14. The sprinkler system to be based on a minimum operating pressure of 40 PSI. The irrigation contractor shall verify water pressures, flows, elevations, and other requirements prior to construction.

Report any differences between the water pressure and flows indicated on drawings and the actual pressure reading at the irrigation point of connection to the owners authorized representative.

15. Installer shall conduct final testing and adjustments to achieve design specifications prior to completion of the system and acceptance by the owner or owner's representative.

16. The installer shall provide property owners and users with post-construction documentation, including as-constructed drawings, recommended maintenance activities and schedules, operational schedule, design precipitation rates, instructions on adjusting the system to apply less water after the landscape is established, maintenance schedule, water source, water shut-off method, and the manufacturer's operation guide for the irrigation controller. To the extent feasible, similar information should be made available for subsequent property transfers.

17. Any changes and/or modifications to the water source shall require appropriate adjustments to the system design.

18. The contractor shall be responsible for providing all code required backflow preventers in addition to all permits as required by the governing agencies including water use permits, if applicable.

19. Plan prepared for code minimum requirements only. Contractor shall provide for a complete operating system.

20. System shall utilize an irrigation meter and backflow. Refer to Civil plans.

PLANTING DETAILS

SHEET TITLE:

SHEET NUMBER:

ISSUED DATE:

AND ASSOCIATES, INC.

LANDSCAPE ARCHITECTS

CONSULTANT:

DAVID M. JONES, JR.

AND PLANNERS

DESIGN PROFESSIONAL:

PROJECT NO.

PREPARED FOR:

REVISIONS:

PROJECT MJR:

FILE NAME:

DESIGNER:

CAD TECH:

CHECKED BY:

ISSUED FOR:

DMJA

GREGORY J DISERIO

NOV. 12, 2024

CALL 48 HOURS

BEFORE YOU DIG

IT'S THE LAW!

DIAL 811 Know what's BELOW.

Call before you dig.

SUNSHINE STATE ONE CALL OF FLORIDA, INC.

2221 McGregor Blvd.

Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494

CFMPRF-Parking_LS

C.F. M. - Parks and Recreation Facility Parking

Addition

FORT MYERS, FL

SITE PERMITTING

224036

Fort Myers, FL 1605 Hendry Street

Fort Myers, FL 33901 Phone: 239.418.0691

GJD

GREGORY J. DISERIO, RLA

R.L.A. #: LA 0000840

STATE OF FLORIDA

GJD

GJD

MARCH 11, 2025 SITE UPDATE

MARCH 28, 2025 PLANT CHANGE

JUNE 11, 2025 RAI RESPONSE

GENERAL LANDSCAPE NOTES

1. THE QUALITY OF ALL PLANT MATERIAL WILL MEET THE STANDARDS FOR FLORIDA GRADE

NO.1 (or better), AS GOVERNED IN "GRADES AND STANDARDS FOR NURSERY PLANTS".

2. ALL PLANTED TREES AND PALMS WILL HAVE A 3" DEEP SAUCER CONSTRUCTED FROM THE

TRUNK OF THE TREE OR PALM. MINIMUM OF 5' DIAMETER.

3. ALL PLANTING BEDS SHALL BE COVERED WITH A 3" MINIMUM DEPTH OF MULCH AND

SHALL BE WEED FREE. MULCH SHALL BE GRADE B OR BETTER. CONTRACTOR SHALL

REMOVE ANY VEGETATIVE GROWTH AND APPLY A PRE-EMERGENT WEED KILLER PER

SPECIFICATIONS PRIOR TO MULCHING.

4. NO CODE REQUIRED PLANTINGS SHALL BE INSTALLED IN EASEMENTS.

5. ANY AND ALL EXOTIC VEGETATION INCLUDING: EARLEAF ACACIA, WOMAN'S TONGUE,

BISHOPWOOD, AUSTRAILIAN PINE, CARROTWOOD, ROSEWOOD, AIR POTATO, MURRAY

RED GUM, WEEPING FIG, CUBAN LAUREL FIG, JAPANESE CLIMBING FERN, OLD WORD

CLIMBING FERN, MELALEUCA, DOWNY ROSE MYRTLE, CHINESE TALLOW, BRAZILLIAN

PEPPER, FLORIDA HOLLY, TROPICAL SODA APPLE, JAVA PLUM, ROSE APPLE, CORK TREE

AND WEDELIA, ON THE PROPERTY SHALL BE COMPLETELY REMOVED AND DISPOSED OF

OFF SITE BY THE CONTRACTOR. THE SITE SHALL BE MAINTAINED FREE OF INVASIVE

EXOTIC VEGETATION IN PERPETUITY.

6. TREES SHALL BE A MINIMUM OF 10' IN HEIGHT WITH A 2" CALIPER MEASURED AT 1' ABOVE

GROUND LEVEL WITH A FOUR FOOT CANOPY.

7. REFER TO LANDSCAPE SPECIFICATIONS FOR ADDITIONAL LANDSCAPE REQUIREMENTS.

8. REFER TO ENGINEERING PLANS FOR ADDITIONAL SPECIFICATIONS.

9. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES

WITH THE LOCATIONS OF ALL UTILITIES AND ALL SITE CONDITIONS PRIOR TO THE START

OF LANDSCAPE INSTALLATION.

10. FERTILIZER SHALL BE IN ACCORDANCE WITH SPECIFICATIONS AND LOCAL ORDINANCES.

11. IT SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TO FINE GRADE ALL

PLANTING AND SODDING AREAS PRIOR TO PLANT OR SOD INSTALLATION. CONTRACTOR

SHALL OBTAIN OWNER APPROVAL OF FINAL GRADES.

12. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE TAKEOFFS. PLANT LIST IS

PROVIDED FOR REFERENCE ONLY.

13. CONTRACTOR SHALL BE RESPONSIBLE FOR LANDSCAPE MAINTENANCE UNTIL FINAL

ACCEPTANCE AND WORK SHALL BE IN COMPLIANCE WITH SPECIFICATIONS.

14. CONTRACTOR SHALL REMOVE ALL TAGS, TAPE AND NURSERY CENTER SUPPORTS

(EXCEPT STAKING GUYS) FROM ALL PLANTINGS PRIOR TO FINAL ACCEPTANCE.

15. ALL AREAS OF THE SITE SHALL BE SODDED OR SEEDED IN ACCORDANCE WITH PLANS.

16. THE REQUIRED PLANTINGS SHALL BE IRRIGATED IN ACCORDANCE WITH CITY

REQUIREMENTS.

17. THE PARKING LOTS SHALL BE SLEEVED FOR IRRIGATION BY THE LANDSCAPE

CONTRACTOR. COORDINATE WITH CIVIL ENGINEERING PLANS.

18. ALL BASE ROCK SHALL BE REMOVED FROM LANDSCAPE PARKING ISLANDS.

19. ALL CODE REQUIRED LANDSCAPING SHALL BE IRRIGATED WITH AN AUTOMATIC

IRRIGATION SYSTEM. SYSTEM TO INCLUDE A RAIN SWITCH SHUT OFF AND ALL BACKFLOW

DEVICES AS REQUIRED BY LOCAL UTILITY PROVIDERS.

20. THE CONTRACTOR SHALL PROVIDE (PRESSURE COMPENSATING SCREENS) AS

NECESSARY TO REDUCE OR ELIMINATE OVERSPRAY INTO STREETS, WALKS OR OTHER

AREAS AS DICTATED BY THE OWNER'S AUTHORIZED REPRESENTATIVE.

21. CONTRACTOR TO PROVIDE BACKFLOW DEVICE AND METERING AS REQUIRED BY CITY OF

FORT MYERS UTILITIES.

PROS-06 SPRAY HEAD WITH PRO-FLEX TUBING

3" = 1'-0"

FINISH GRADE

MODEL PROS-06 SPRAY HEAD

SWING JOINT:

HUNTER 'PRO-FLEX' TUBING,

HSBE-050 ELBOWS (2), &

MARLEX STREET ELBOW (1)

LATERAL TEE OR ELL

LATERAL PIPE

FX-IR-HUNT-SPRA-32

AutoCAD SHX Text

L.A. LICENSE: LC COOOO63

AutoCAD SHX Text

PROJECT INFORMATION:

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text

IRRIGATION DETAIL

AutoCAD SHX Text

SCALE: 1" = 1'-0"

AutoCAD SHX Text

XX

AutoCAD SHX Text

ICV GLOBE VALVE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REMOTE CONTROL VALVE MODEL ICV-XXXG ACCU-SYNC-ADJ

AutoCAD SHX Text

3/4" MINUS WASHED GRAVEL

AutoCAD SHX Text

MAIN LINE PIPE & FITTINGS

AutoCAD SHX Text

SCH 80 T.O.E. NIPPLE

AutoCAD SHX Text

BRICK SUPPORTS (4)

AutoCAD SHX Text

WATERPROOF CONNECTORS (2)

AutoCAD SHX Text

18-24" COILED WIRE

AutoCAD SHX Text

FINISH GRADE

AutoCAD SHX Text

STANDARD VALVE BOX

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PVC SLIP UNIONS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PVC SLIP UNIONS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Michigan ave.

se a b o a r d s t.

P A

LM

a v e

M

1"

2"

2"

2"

2"

1" 1"11 2"

1" 1"

2"

1"11 2"

1"

2"

2"

1"

2"1"

2"

2"

1"

2"

1"

2"

1"

2"

1"11 2"

1"

1"

1" 11 2"

1"

2" 1"

2"

1"

2"

1" 11 2"

2"

112"

2"

2"

Crs

38.0112"

30112"

32.1112"

25112"

35.3112"

33.5112"

24112"

36.6112"

1"

1"

2"

2"

2"

1"

2"

SS

PLAN SCALE REDUCED WHEN PRINTED 11x17

IRRIGATION PLAN

IR-1-S

IRRIGATION PLAN

SCALE 1" = 20'

0' 10' 20' 40' 60'

INTERNAL UTILITY EASEMENT - NO TREES OR LARGE

SHRUBS SHALL BE PLANTED INSIDE THESE ZONES.

ALL TREES IN ISLANDS ARE LOCATED OUTSIDE OF

EASEMENT, MIN. 10' FROM BACK OF CURB

N

SHEET TITLE:

SHEET NUMBER:

ISSUED DATE:

AND ASSOCIATES, INC.

LANDSCAPE ARCHITECTS

CONSULTANT:

DAVID M. JONES, JR.

AND PLANNERS

DESIGN PROFESSIONAL:

PROJECT NO.

PREPARED FOR:

REVISIONS:

PROJECT MJR:

FILE NAME:

DESIGNER:

CAD TECH:

CHECKED BY:

ISSUED FOR:

DMJA

GREGORY J DISERIO

NOV. 12, 2024

CALL 48 HOURS

BEFORE YOU DIG

IT'S THE LAW!

DIAL 811 Know what's BELOW.

Call before you dig.

SUNSHINE STATE ONE CALL OF FLORIDA, INC.

2221 McGregor Blvd.

Fort Myers, Florida 33901 Phone: (239) 337 - 5525 Fax: (239) 337 - 4494

CFMPRF-Parking_LS

C.F. M. - Parks and Recreation Facility Parking

Addition

FORT MYERS, FL

SITE PERMITTING

224036

Fort Myers, FL 1605 Hendry Street

Fort Myers, FL 33901 Phone: 239.418.0691

GJD

GREGORY J. DISERIO, RLA

R.L.A. #: LA 0000840

STATE OF FLORIDA

GJD

GJD

MARCH 11, 2025 SITE UPDATE

MARCH 28, 2025 PLANT CHANGE

JUNE 11, 2025 RAI RESPONSE

3/4"

2-1/2"

1-1/4" 1-1/2"

SIZE

51-70 31-50 2"

GPM

Not Used

14-30 Not Used 113 1"

S C

H E

D U

LE

Flows shall maintain velocities of less than 5 feet per second

SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY

Hunter PROS-06-PRS40 12 Series Shrub Spray, 40 psi regulated 6in. pop-up

Hunter PROS-06-PRS40 15 Series Shrub Spray, 40 psi regulated 6in. pop-up

Hunter PCB Flood Bubbler, 1/2in. FIPT.

SYMBOL MANUFACTURER/MODEL

Hunter ICV-G

Hunter I2C-1600-M

Hunter MINI-CLIK

Water Meter 1-1/2"

Irrigation Lateral Line: PVC Schedule 40

Irrigation Mainline: PVC Schedule 40

Pipe Sleeve: PVC Class 200 SDR 21

C rs

M

IRRIGATION SCHEDULE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

L.A. LICENSE: LC COOOO63

AutoCAD SHX Text

PROJECT INFORMATION:

AutoCAD SHX Text Q

AutoCAD SHX Text T

AutoCAD SHX Text H

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text T

AutoCAD SHX Text H

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Valve Number

AutoCAD SHX Text Valve Flow

AutoCAD SHX Text Valve Size

AutoCAD SHX Text Valve Callout

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
CFMPRF-Parking_LS-L-1
CFMPRF-Parking_LS-L-2a
CFMPRF-Parking_LS-L-3
CFMPRF-Parking_LS-IR-1
2025-07-23T16:22:41-0400
Gregory J. Diserio, RLA
2025-07-23T16:22:55-0400
Gregory J. Diserio, RLA
2025-07-23T16:23:13-0400
Gregory J. Diserio, RLA
2025-07-23T16:23:29-0400
Gregory J. Diserio, RLA

File details come from the government source that posted it. Updated .