20250619_-_Warehouse_Convert_to_Parks_&_Rec_Department_100%_CD_KMW.pdf
PDF 28 MB Posted
- Attached to
- Michigan Avenue Warehouse Renovation
- Solicitation number
- ITB 25-098
- Issued by
- Lee County, Fruitville CDP, Florida
About this file
This document is a comprehensive architectural set of construction drawings and specifications for the City of Fort Myers, Florida, detailing the renovation of two existing warehouse buildings located at 2801 Michigan Avenue. The project involves converting the warehouses into a new Parks & Recreation Department facility and City Records center, with work to be performed on both the north and south buildings. The renovations include transforming the existing structures, built in the 1980-1990s, to meet current building code requirements, with the south building designated for Parks and Recreation offices and the north building dedicated to records storage. The project encompasses architectural, structural, mechanical, electrical, and plumbing work, with multiple alternative options for finishes, room configurations, and specific building elements.
The total project area spans approximately 17,694 square feet across both buildings, with the north building measuring 7,100 square feet and the south building measuring 10,594 square feet. The renovation includes creating office spaces, conference rooms, restrooms, storage areas, and mechanical spaces, with specific attention to accessibility, life safety requirements, and building code compliance. Alternative bid options include changing floor finishes, converting cubicles to private offices, replacing dock canopies, and potential roof panel replacements. The project is fully sprinklered and designed as a mixed-occupancy building with business, storage, and assembly spaces. Funding and specific budget details are not explicitly outlined in the documents, but the comprehensive drawings suggest a thorough and structured approach to modernizing these municipal facilities.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SITE
8 STATE OF
FLORIDA
5039RA TCETI HCRA DERE
TSI
GE
R
CIL 72
DI
EDROIRETNI
RENGIS
SM
AI
LLIWLEAHCIMNIVEK
PROJECT NO:
DATE:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
SEE SHEETS G001/G002 FOR
GENERAL NOTES APPLICABLE TO
THE ENTIRE DRAWING SET
6/
/2
:2 8:
A
M
Au to de sk
D oc s:
//W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t/4
W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t_ Ba se B id .rv t
G000
COVER SHEET
40-24105
W A R
EH
O U
SE
C O N
VE
R
SI
O N T O C
LE
R K O F C O U R T
R
EC
O R D S
C
IT
Y O
F
FO
R T
M
YE
R S
06/19/2025
PERMIT DOCUMENTS
S
EC
O N
D S
TR
EE
T
FO
R T
M
YE
R S, F L
WAREHOUSE CONVERSION TO CLERK OF COURT RECORDS
PERMIT DOCUMENTS
06/19/2025
VICINITY MAP
PROJECT DESCRIPTION
The project’s location is to be used for the new Parks & Recreation Department, as well as City Records Facility offices and center of operations. The site is located at 2801 Michigan Avenue, Fort Myers, and it’s composed of two main warehouse buildings and parking areas.
The existing buildings were erected back in the1980-1990, and as such the facilities need repairs and upgrades to make them functional and compliant with current building code requirements.
In general, the new facilities program is to house the New Parks and Recreation Department’s offices in the south building, while the north building is to be dedicated for the Records storage and related functions.
RESPEC
1412 JACKSON STREET, SUITE #1
FORT MYERS, FL 33901
(239) 418-0691
CIVIL ENGINEER & LANDSCAPE
MATTERN PROFESSIONAL ENGINEERING
12437 BRANTLEY COMMONS CT.
FORT MYERS, FL 33907
(239) 332-1187
MECHANICAL & ELECTRICAL ENGINEER
SELECT STRUCTURAL, INC.
5621 BANNER DRIVE
FORT MYERS, FL 33912
(239) 278-1992
STRUCTURAL ENGINEER
GRACE HEBERT CURTIS ARCHITECTS, LLC
501 GOVERNMENT STREET, SUITE 200
BATON ROUGE, LA 70802
225.338.5569
ARCHITECT
THE CITY OF FORT MYERS
2220 SECOND STREET
FORT MYERS, FL 33901
(239) 321-7000
OWNER
PROJECT DIRECTORY NO. DESCRIPTION DATE
kwilliams Stamp
OFFICE
DRAWING NAME
A2.1
A3.2
A7.2
A6.1
ROOM NAME
NUMBER
REVISION
NUMBER
DRAWING NUMBER
DRAWING SCALE
SCALE : 1/4" = 1'-0"
34 KEY NOTE
109'-0"
DRAWING NUMBER
SHEET NUMBER
SHEET NUMBER
DRAWING NUMBER INTERIOR
ELEVATION
DETAIL
4 A4.1
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
DRAWING NUMBER
SHEET NUMBER
DETAIL SECTION
EXTERIOR
ELEVATION
SECTION
DRAWING NAME
LEVEL LINE
1.
2.
3.
4.
5.
6.
7.
8.
GENERAL
ARCHITECTURAL DOCUMENTS SHALL BE COORDINATED WITH ALL
OTHER DISCIPLINES’ DOCUMENTS. ANY DISCREPANCY BETWEEN THESE
DOCUMENTS SHOULD BE REPORTED TO THE ARCHITECT FOR
CLARIFICATION AND VERIFICATION PRIOR TO PROCUREMENT OR
INSTALLATION OF AFFECTED WORK.
DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED.
WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE
DETERMINED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH
AFFECTED WORK.
PROTECT ALL MATERIALS, CONSTRUCTION, UTILITIES AND FACILITIES
FROM DAMAGE, INCLUDING BUT NOT LIMITED TO CONSTRUCTION
ACTIVITIES, THEFT, MOISTURE, AND WEATHER. DAMAGED ELEMENTS
AND CONDITIONS SHALL BE REPAIRED / REPLACED AT NO COST TO
OWNER.
DO NOT SCALE ANY DRAWINGS IN ANY OF THE DOCUMENTS FOR FIELD
LAYOUT. CONTACT ARCHITECT IF DIMENSIONS ARE NEEDED AND
CANNOT BE FOUND IN WRITING IN THE DOCUMENTS.
INFORMATION ON G SHEETS IS INTENDED TO BE TYPICAL. SOME
INFORMATION SHOWN MAY NOT BE RELEVANT TO PROJECT SPECIFICS.
REVIEW THE DOCUMENTS AND CONFIRM IN WRITING WITH DESIGN TEAM
WHICH INFORMATION IS NOT RELEVANT TO PROJECT SPECIFICS PRIOR
TO THE START OF CONSTRUCTION.
REFER TO LEGENDS, SCHEDULES, AND KEYNOTES ON INDIVIDUAL
SHEETS FOR SPECIFIC INFORMATION
HOLD ALL PIPES, CONDUIT, BRANCH LINES, ETC. AS CLOSE TO THE
UNDERSIDE OF STRUCTURE AS POSSIBLE. USE LOW PROFILE
HANGERS WHERE POSSIBLE.
TEMPORARY SHORING AS REQUIRED DURING DEMOLITION AND
CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
9. PROVIDE ACCESS PANELS AT WALLS AND CEILINGS FOR:
FIRE/SMOKE DAMPERS, VAV BOXES, PLUMBING CLEANOUTS,
ELECTRIC HEATERS, AIR HANDLING UNITS/MECHANICAL EQUIPMENT,
VALVES, FILTER BOXES AND OTHER CONCEALED ITEMS REQUIRING
ACCESS. COORDINATE WITH ARCHITECT IN FIELD FOR INSTALLATION
OF ACCESS PANELS WHERE REQUIRED AND NOT GRAPHICALLY SHOWN
ON PLANS.
10.
A.
B.
C.
D.
E.
11.
12.
13.
14.
DIMENSIONS IN THE DOCUMENTS ARE AS LISTED BELOW.
DIMENSIONS ARE TAKEN FROM ([PICK ONE] FACE OF STUD /
COLUMN UNLESS OTHERWISE NOTED.
"CLEAR" REFERS TO DIMENSION BETWEEN FACES OF FINISH
SURFACES.
"EQ" OR "EQUAL" INDICATES DIMENSION TO MATCH ADJACENT.
LETTERED DIMENSIONS (A,B,C,D,ETC.) INDICATE DIMENSION TO
MATCH OPPOSITE OR REMOTE (MATCHING LETTER) DIMENSION.
"+/-" INDICATES APPROXIMATE DIMENSION BASED ON FIELD
CONSITION OR FLEXIBLE DIMENSION THAT CAN BE ADJUSTED.
DIMENSIONS ON REFLECTED CEILING PLANS AND LIGHTING PLANS
ARE CLEAR DIMENSIONS.
ASBESTOS ABATEMENT, LEAD PAINT REMOVAL, AND OTHER
HAZARDOUS MATERIAL REMOVAL IS NOT IN THE CONTRACT. SHOULD
THE CONTRACTOR ENCOUNTER THE PRESENCE, OR POSSIBLE
PRESENCE, OF POTENTIALLY HAZARDOUS MATERIALS, THE
CONTRACTOR SHALL NOTIFY THE OWNER FOR INSTRUCTIONS PRIOR
TO CONTINUING WORK.
BUILDINGS SHALL BE PROVIDED IN WEATHERPROOF AND SECURE
CONDITION AS EARLY AS POSSIBLE AND MAINTAINED THROUGHOUT
WORK.
FURNITURE IS FOR REFERENCE ONLY UNLESS OTHERWISE NOTED.
REFERNCE FURNITURE IS NOT IN PROJECT SCOPE.
THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED
INSPECTIONS, TEMPORARY UTILITIES AND TEMPORARY TOILET
FACILITIES. THE CITY OF FORT MYERS WILL PAY FOR ALL THE PERMITS
1.
2.
3.
4.
5.
6.
DEMOLITION
DURING THE COURSE OF THE WORK ITEMS UNCOVERED THAT VARY
FROM WHAT IS IDENTIFIED IN THE DOCUMENTS SHALL BE
IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT
PRIOR TO PROCEEDING WITH AFFECTED WORK. THIS INCLUDES BUT
IS NOT LIMITED TO COMPONENT SIZES, LOCATIONS,
CONFIGURATIONS AND DAMAGED, DETERIORATED, MALFUNCTIONING
OR BROKEN COMPONENTS
IF NOT SHOWN IN THE DRAWINGS THE CONTRACTOR SHALL REMOVE
ALL EXISTING MATERIALS AND CONSTRUCTION AS NECESSARY TO
COMPLETELY INSTALL ALL NEW WORK AS REQUIRED BY OTHER
PARTS OF THE CONTRACT DOCUMENTS.
LOCATIONS OF TEMPORARY CONSTRUCTION BARRIERS/DUST
PARTITIONS TO BE COORDINATED WITH THE OWNER.
REMOVE ALL CONSTRUCTION DEBRIS AND TRASH DAILY. PROVIDE
SEALED COVERINGS FOR ALL BINS OR BARROWS USED TO REMOVE
DEBRIS, MATERIALS AND TRASH THROUGH OCCUPIED AREAS OF THE
BUILDING.
REMOVE ALL EXISTING CONSTRUCTION IN CONFLICT WITH NEW
DESIGN. COORDINATE WITH DESIGN TEAM IF ELEMENTS OF EXISTING
CONSTRUCTION REQUIRED TO BE DEMOLISHED ARE NOT SHOWN ON
DEMOLITION PLANS.
NOT ALL SELECTIVE DEMOLITION IS IDENTIFIED ON ARCHITECTURAL
DRAWINGS. CONTRACTOR IS TO COORDINATE WITH MECHANICAL,
ELECTRICAL, AND PLUMBING DRAWINGS TO VERIFY EXTENTS OF
DEMOLITION REQUIRED TO ACCOMMODATE COMPLETE INSTALLATION
OF MECHANICAL, ELECTRICAL, AND PLUMBING COMPONENTS. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO FULLY CONDUCT THIS
COORDINATION PRIOR TO BID.
7.
8.
9.
10.
LIFE SAFETY FEATURES, INCLUDING SPRINKLER SYSTEM, FIRE ALARM
SYSTEM, ETC. MUST REMAIN ACTIVE DURING CONSTRUCTION.
PROTECT AND PRESERVE ALL EXIT SIGNS IN AREAS TO REMAIN AND
ENSURE EXIT SIGNS REMAIN OPERATIONAL THROUGHOUT THE
DURATION OF CONSTRUCTION.
UNLESS OTHERWISE NOTED, PARTITIONS TO BE REMOVED FROM
FLOOR SLAB TO UNDERSIDE OF STRUCTURE OR TOP RUNNER AS
APPLICABLE.
REMOVAL OF FIXTURES AND EQUIPMENT IS NOT LIMITED TO WHAT IS
SHOWN ON DRAWINGS. IT IS INDICATED FOR GENERAL
CONTRACTOR'S INFORMATION ONLY. PRIOR TO BID VERIFY ON JOB
FOR EXACT TYPE, LOCATION AND NUMBER OF ITEMS TO BE
REMOVED TO MEET REQUIREMENTS OF PLANS AND SPECIFICATIONS.
AT CONSTRUCTION ENTRANCES/EXITS TO THE OCCUPIED PORTIONS
OF THE BUILDING PROVIDE TEMPORARY DUST MATS AND CLEAN
THEM WEEKLY.
1.
1.
2.
3.
4.
FLOOR PLAN:
ALL DOORS TO BE 4" TO 6” FROM FINISH FACE OF ADJACENT
PARTITION AS MEASURED TO OUTSIDE FACE OF DOOR JAMB UNLESS
OTHERWISE NOTED.
CEILING PLAN:
CENTER ALL CEILING MOUNTED DEVICES INCLUDING BUT NOT LIMITED
TO LIGHT FIXTURES, EXIT LIGHTS, SPRINKLER HEADS, SPEAKERS IN
CEILING TILE PANELS.
CENTER CEILING GRID IN ROOM IN BOTH DIRECTIONS UNLESS
INDICATED OTHERWISE.
ALL LIGHT FIXTURES IN GYPSUM BOARD CEILING SHALL BE CENTERED
IN ROOM UNLESS INDICATED OTHERWISE.
ALL GYPSUM BOARD SOFFITS ARE TO BE FINISHED WITH NO EXPOSED
EDGES OR VIEWS INTO THE PLENUM SPACE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
ROOF PLAN NOTES:
SLOPE ROOF MEMBRANE ¼” PER FOOT MINIMUM, SLOPE
CRICKETS AT ½” PER FOOT MINIIMUM.
CRICKET THE UP SLOPE SIDE OF ALL SQUARE CURBS AND
PROJECTIONS OVER 20 INCHES IN WIDTH.
ALL ROOF DRAINS, OVERFLOW DRAINS AND DOWNSPOUTS TO BE
CONNECTED TO SUBSURFACE DRAINAGE UNLESS NOTED
OTHERWISE. SEE CIVIL FOR CONNECTION OF ROOF DETAINAGE
SYSTEM TO UNDERGROUND SERVICES.
PROVIDE ROOF MEMBRANE SYSTEM AT INTERIOR (ROOF) SIDE OF
VERTICAL PARAPET WALLS WHERE PARAPET WALL IS 2 ’-0” HIGH
OR LESS. PROVIDE METAL WALL PANEL SIDING SYSTEM AT
INTERIOR (ROOF) SIDE OF VERTICAL PARAPET WALLS WHERE
PARAPET WALLS ARE OVER 2’-0” HIGH
ALL ROOF MATERIALS AND ACCESSORIES TO BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER ’S WRITTEN
INSTRUCTIONS, RECOMMENDATIONS, AND SPECIFICATIONS TO
ACHIEVE SPECIFIED WARRANTY AND PROVIDE WEATHERTIGHT
ROOF SYSTEM. (AND NRCA STANDARDS)
COORDINATE ALL ROOF PENETRATIONS AND EQUIPMENT /
PLATFORM SUPPORTS WITH ROOF STRUCTURE AND ROOFING
INSTALLATION AND FLASHING REQUIREMENTS.
ROOF MEMBRANE SOLUTIONS - IF USED / INSTALLED - SYSTEM
SHALL TURN UP OVER TOP OF COPING CAP, TO BE FLASHED INTO
WALL WRB SYSTEM TO ACHIEVE CONTINUOUS UNINTERRUPTED
BUILDING ENVELOPE WEATHER BARRIER SYSTEM
PROVIDE WALK PAD SYSTEM COMPATIBLE WITH SPECIFIED ROOF
SYSTEM, SPANNING FROM ROOF ACCESS POINT TO MAINTENANCE
SIDES OF ALL ROOFTOP EQUIPMENT.
ALL ROOF MOUNTED EQUIPMENT STANDS, CURBS,
PENETRATOINS, ACCESSORIES, UTILITIES, ETC. TO BE FLASHED
INTO ROOF SYSTEM AS REQUIRED TO ACHIEVE SPECIFIED
WARRANTY.
PACK, SCREEN, INSULATE, AND SEAL ALL ROOF PENETRATION
SYSTEMS AS REQUIRED TO PREVENT ALL OUTSIDE AIR,
MOISTURE, ANIMALS, INSECTS, ETC. FROM COMMUNICATING WITH
FRAMING CAVITY BELOW DECK.
DO NOT LOCATE ANY ROOFTOP EQUIPMENT WITHIN 10 ’ OF ROOF
EDGE UNLESS OTHERWISE NOTED
PROVIDE INSULATED PREFABRICATED ROOF HATCH, FLASHED
INTO SPECIFIED ROOF SYSTEM AS REQUIRED TO ACHIEVE
SPECIFIED WARRANTY
ALL PIPING, CONDUITS, ETC. SHAL BE A MINIMUM 10” ABOVE ROOF
SURFACE. PROVIDE PIPE SUPPORTS AT 8’-0” MAX.
AFTER SUBSTANTIAL COMPLETOIN EXAMINE AND ENSURE ROOF
DRAIN LINES ARE FREE OF DEBRIS AND BLOCKAGE. FLUSH WITH
WATER TO ENSURE THAT DRAINS FLOW FREELY.
ISOLATE ALL HEAT PIPES/FLUES AS RECOMENDED AND OUTLINED
IN THE NRCA MANUAL FOR ISOLATED STACK FLASHING.
ALL ROOFTOP PENETRATIONS (SOIL STACKS, VENTS, ETC.) ARE
INSTALLED MINIMUM 4’-0” FROM OTHER DECK PENETRATIONS,
RISE WALLS, AND ROOF EDGE.
DIMENSIONS, DETAILS, EQUPMENT SIZES AND LOCATIONS SHOWN
ON THESE ROOF PLANS AND DETAILS AR FOR INFORMATION AND
REFERENCE ONLY. EXACT SIZE AND LOCATIONS TO BE
COORDINATED WITH ALL DISCIPLINES.
REFER TO OTHER DISCIPLINES FOR SIZE AND LOCATIONS OF NEW
DECK PENETRATIONS AND ROOFTOP EQUIPMENT.
ALL SHEETMETAL SHALL BE INSTALLED TO COMPLY WITH THE
LATEST EDITION OF SMACNA’S ARCHITECTURAL SHEET METAL
MANUAL.
ANCHOR ROOFTOP UNITS SECUREY IN PLACE WITH METHODS
INDICATED PROVIDING FOR THERMAL EXPANSION OF METAL
UNITS. CONCEAL FASTENERS WHERE POSSIBLE AND SET UNITS
TRUE TO LINE AND LEVEL. EXPOSED EDGES SHALL BE FOLDED
BACK NEATLY FROM A ½" HEM ON THE CONCEALED EDGE. INSTALL
WORK WITH LAPS, JOINTS AND SEAMS WHCIH WILL BE
WATERTIGHT AND WATERPROOF.
A ½" HEM ON THE CONCEALED EDGE. INSTALL WORK WITH LAPS,
JOINTS AND SEAMS WHCIH WILL BE WATERTIGHT AND
WATERPROOF.
1.
2.
3.
4.
5.
6.
SITE PLAN NOTES:
SLOPE ALL PAVING AND GRADING AWAY FROM BUILDING TO ACHIEVE
POSITIVE DRAINAGE AND TO ELIMINATE PONDING WATER ON SITE
IMMEDIATELY NOTIFY DESIGN TEAM IF UNDOCUMENTED UTILTIES ARE
DISCOVERED ON SITE
ALL EXTERIOR LEVEL LANDINGS SHALL BE OFFSET ½” MAXIMUM
FROM FINISH FLOOR, NEVER EXCEED 1.8% SLOVE AND SLOPE AWAY
FROM THE BUILDING ¼” PER FOOT MAXIMUM.
PROVIDE HOSE STORAGE AT DUMPSTER ENCLOSURES
MUNICIPAL INFRASTRUCTURE REFER TO CIVIL ENGINEERING PLANS
RESTORE ALL DAMAGED SIDEWALKS AND CURBS TO THE
STANDARDS OF THE AUTHORITY HAVING JURISDICTION.
STATE FLORIDA
HISTORIC DISTRICT INFO. N/A
OTHER ZONE CLASSIFICATIONS N/A
CITY FORT MYERS
8 STATE OF
FLORIDA
5039RA TCETI HCRA DERE
TSI
GE
R
CIL 72
DI
EDROIRETNI
RENGIS
SM
AI
LLIWLEAHCIMNIVEK
PROJECT NO:
DATE:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
SEE SHEETS G001/G002 FOR
GENERAL NOTES APPLICABLE TO
THE ENTIRE DRAWING SET
6/
/2
:2 8:
A
M
Au to de sk
D oc s:
//W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t/4
W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t_ Ba se B id .rv t
G001
DRAWING INDEX +
GENERAL INFORMATION
40-24105
W A R
EH
O U
SE
C O N
VE
R
SI
O N T O C
LE
R K O F C O U R T
R
EC
O R D S
C
IT
Y O
F
FO
R T
M
YE
R S
06/19/2025
PERMIT DOCUMENTS
S
EC
O N
D S
TR
EE
T
FO
R T
M
YE
R S, F L
AC ACOUSTICAL CEILING TILE
ADAAG AMERICANS WITH DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECT
BB BEAD BOARD (WAINSCOTT)
BD BOARD
BLDG BUILDING
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BUR BUILT UP ROOF
C CARPET OR CARPET TILE
CAB CABINET
CB CATCH BASIN
CC CUBICLE CURTAIN TRACK
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLOS CLOSET
CLR CLEAR
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CR CRASH RAIL
CRM CROWN MOULDING
CTR CENTER
DBL DOUBLE
DET DETAIL
DF DECORATIVE FILM
DFC DOOR FRAME CASING
DIA DIAMETER
DIM DIMENSION
DM DECORATIVE METALS
DN DOWN
DR DOOR
DS DOWN SPOUT
DW DISHWASHER
DWG DRAWING
E EAST
EA EACH
EF EPOXY FLOORING
EHD ELECTRIC HAND DRYER
EIFS EXTERIOR INSULATED FINISHING SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRIC(AL)
ELEV ELEVATION
EMER EMERGENCY
EQ EQUAL
ABBREVIATIONS
DRAWING INDEX
SYMBOLS
GENERAL NOTES ZONING
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXP. JT. EXPANSION JOINT
EXST EXISTING
EXT EXTERIOR
FA FIRE ALARM
FAP FIRE ANNUNCIATOR PANEL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FLUOR FLORESCENT
FRP FIBERGLASS REINFORCED PLASTIC PANEL
FT FOOT or FEET
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GL GLASS
GND GROUND
GWB GYPSUM WALL BOARD
GYP GYPSUM
HC HANDICAPPED
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HAND RAIL
HT HEIGHT
HW HAND WASH
HWH HOT WATER HEATER
ID INNER (OR INSIDE) DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JC JANITOR'S CLOSET
JT JOINT
KP KICK PLATE
LAM LAMINATE
LAV LAVATORY
LB(S) POUNDS
LDG LANDING
LF LINOLEUM FLOORING
LT LIGHT
LVT LUXURY VINYL TILE
LWC LINEAR WOOD CEILING
M MISCELLANEOUS
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MI MIRROR
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OPPOSITE HAND
OP OVERFLOW PIPE
OPG OPENING
OPP OPPOSITE
P PAINT
PC PRIVACY CURTAIN
PCN PAINTED CONCRETE
PL PLASTIC LAMINATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PR PAIR
QS QUARTZ SURFACE
R RISER
RAD RADIUS
RB RUBBER WALL BASE
RBM RUBBER WALL BASE MILWORK PROFILE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER
REF REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
RF RUBBER FLOORING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RR RUB RAIL
S SOUTH
SC SCUPPER
SC SEALED CONCRETE
SCHED SCHEDULE
SDT STATIC DISSIPATIVE FLOORING
SECT SECTION
SF SQUARE FOOT
SF SEAMLESS FLOORING
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
ST STONE
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SWP SPECIALTY WALL PANELS
T TREAD
T TRANSITION STRIP
T&G TONGUE & GROOVE
TEL TELEPHONE
THK THICK
TL TILE
TLT TOILET
TO TOP OF
TOS TOP OF STEEL
TP TOILET PARTITION
TR TRIM
TS TACKABLE SURFACE
TYP TYPICAL
TZ TERRAZZO
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VCF VINYL COMPOSITION FLOORING
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VOJ VERIFY ON JOB
VTR VENT TERMINATION PIPE
W WEST
W/ WITH
W/O WITHOUT
WB WOOD BASE
WC WALL COVERING
WC WATERCLOSET
WD WOOD
WIN WINDOW
WP WATERPROOF
WP WALL PROTECTION
WS WOOD STAIN
WT WEIGHT
WT WINDOW TREATMENTS
WV WOOD VENEER
WWF WELDED WIRE FABRIC
ARCHITECTURE SHEETSARCHITECTURE SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
A101 1ST AND 2ND FLOOR PLANS NORTH BUILDING 06/19/2025
A102 1ST FLOOR PLAN SOUTH BUILDING 06/19/2025
A102-2 ALTERNATIVE 2 - 1ST FLOOR PLAN SOUTH BUILDING 06/19/2025
A141 OVERALL REFLECTED CEILING PLAN - NORTH BUILDING 06/19/2025
A142 OVERALL REFLECTED CEILING PLAN - SOUTH BUILDING -
FIRST FLOOR
06/19/2025
A142-2 ALTERNATIVE - OVERALL REFLECTED CEILING PLAN -
SOUTH BUILDING - FIRST FLOOR
06/19/2025
A145 CEILING DETAILS 06/19/2025
A151 ROOF PLAN 06/19/2025
A201 NORTH BUILDING - NORTH & EAST ELEVATIONS 06/19/2025
A202 NORTH BUILDING - WEST & SOUTH ELEVATIONS 06/19/2025
A203 SOUTH BUILDING - EAST & NORTH ELEVATIONS 06/19/2025
A204 SOUTH BUILDING - WEST & SOUTH ELEVATIONS 06/19/2025
A301 BUILDING SECTIONS - NORTH BUILDING 06/19/2025
A302 BUILDING SECTIONS - SOUTH BUILDING 06/19/2025
A320 WALL SECTIONS 06/19/2025
A321 SECTION DETAILS 06/19/2025
A401 SOUTH BUILDING - ENLARGED PLANS & INTERIOR
ELEVATIONS
06/19/2025
A402 SOUTH BUILDINGS - ENLARGED PLANS & INTERIOR
ELEVATIONS
06/19/2025
A403 SOUTH & NORTH BUILDINGS - ENLARGED PLANS &
INTERIOR ELEVATIONS
06/19/2025
A502 SIGNAGE ELEVATION AND SCHEDULE 06/19/2025
A601 DOOR SCHEDULE 06/19/2025
A601-2 ALTERNATIVE 1 - DOOR SCHEDULE 06/19/2025
A602 DOOR DETAILS 06/19/2025
A605 ROOM SCHEDULE & EQUIPMENT SCHEDULE 06/19/2025
A605-2 ALTERNATIVE - ROOM SCHEDULE & EQUIPMENT
SCHEDULE
06/19/2025
A606 TYPICAL WINDOW & STOREFRONT DETAILS 06/19/2025
A901 SOUTH BUILDING - RENDERING 06/19/2025
A902 SOUTH BUILDING - RENDERING 06/19/2025
A903 SOUTH BUILDING - RENDERING 06/19/2025
GENERAL SHEETSGENERAL SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
G000 COVER SHEET 06/19/2025
G002 TYPICAL TOILET & SPECIALTY EQUIPMENT INFORMATION 06/19/2025
G003 PARTITION TYPES 06/19/2025
G004 TYPICAL PARTITION DETAILS 06/19/2025
G005 UL ASSEMBLIES 06/19/2025
STRUCTURAL SHEETSSTRUCTURAL SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
S1.0 GENERAL NOTES 06/19/2025
S2.0 PARTIAL FOUNDATION PLANS 06/19/2025
S3.0 PARTIAL STRUCTURAL PLANS 06/19/2025
S3.1 CEILING FRAMING 06/19/2025
S4.0 TYPICAL DETAILS 06/19/2025
S4.1 FOUNDATION DETAILS 06/19/2025
S5.0 FRAMING DETAILS 06/19/2025
MECHANICAL SHEETSMECHANICAL SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
M001 GENERAL NOTES, LEGEND, ABBREVIATIONS & SHEET
INDEX
06/19/2025
M101-N 1ST AND 2ND FLOOR PLANS - NORTH BUILDING -
MECHANICAL
06/19/2025
M101-S 1ST FLOOR PLAN - SOUTH BUILDING - MECHANICAL 06/19/2025
M101-S-2 1ST FLOOR PLAN - SOUTH BUILDING - MECHANICAL -
ALTERNATE
06/19/2025
M201 SECTION VIEWS - MECHANICAL 06/19/2025
M502 CONTROLS - MECHANICAL 06/19/2025
M503 CONTROLS - MECHANICAL 06/19/2025
M504 CONTROLS - MECHANICAL 06/19/2025
M601 SCHEDULES - MECHANICAL 06/19/2025
M601-2 SCHEDULES - MECHANICAL - ALTERNATE 06/19/2025
M901 DETAILS - MECHANICAL 06/19/2025
M902 DETAILS - MECHANICAL 06/19/2025
M903 DETAILS - MECHANICAL 06/19/2025
MD101-N 1ST AND 2ND FLOOR DEMOLITION PLANS - NORTH
BUILDING - MECHANICAL
06/19/2025
MD101-S 1ST FLOOR DEMOLITION PLAN - SOUTH BUILDING -
MECHANICAL
06/19/2025
ELECTRICAL SHEETSELECTRICAL SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
E001 GENERAL NOTES, LEGEND, ABBREVIATIONS & SHEET
INDEX
06/19/2025
E001-2 GENERAL NOTES, LEGEND, ABBREVIATIONS & SHEET
INDEX
06/19/2025
E002 ELECTRICAL SYMBOL LEGEND 06/19/2025
E003 ELECTRICAL SYMBOL LEGEND 06/19/2025
E010 ELECTRICAL SITE PLAN - POWER AND SYSTEMS 06/19/2025
E041 ELECTRICAL SITE PLAN - LIGHTING 06/19/2025
E042-N ELECTRICAL SITE PLAN - PHOTOMETERICS 06/19/2025
E042-S ELECTRICAL SITE PLAN - PHOTOMETERICS 06/19/2025
E111-N POWER - 1ST AND 2ND FLOOR PLANS - NORTH BUILDING 06/19/2025
E111-S POWER - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
E111-S-2 POWER - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
E112 ELECTRICAL ROOF PLANS 06/19/2025
E311-N SYSTEMS - 1ST AND 2ND FLOOR PLANS - NORTH
BUILDING
06/19/2025
E311-S SYSTEMS - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
E311-S-2 SYSTEMS - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
E411-N LIGHTING - 1ST AND 2ND FLOOR PLANS - NORTH
BUILDING
06/19/2025
E411-S LIGHTING - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
E411-S-2 LIGHTING - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
E501 ELECTRICAL RISER DIAGRAMS 06/19/2025
E501-2 ELECTRICAL RISER DIAGRAMS 06/19/2025
E601 ELECTRICAL PANEL SCHEDULES 06/19/2025
E601-2 ELECTRICAL PANEL SCHEDULES 06/19/2025
E602 ELECTRICAL PANEL SCHEDULES 06/19/2025
E701 MECHANICAL FEEDER SCHEDULES 06/19/2025
E901 ELECTRICAL DETAILS 06/19/2025
ED111-N POWER & SYSTEMS - 1ST AND 2ND FLOOR DEMOLITION
PLANS - NORTH BUILDING
06/19/2025
ED111-S POWER & SYSTEMS - 1ST FLOOR DEMOLITION PLAN -
SOUTH BUILDING
06/19/2025
ED411-N LIGHTING - 1ST AND 2ND FLOOR DEMOLITION PLANS -
NORTH BUILDING
06/19/2025
ED411-S LIGHTING - 1ST FLOOR DEMOLITION PLAN - SOUTH
BUILDING
06/19/2025
PLUMBING SHEETSPLUMBING SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
P001 GENERAL NOTES, LEGEND, ABBREVIATIONS & SHEET
INDEX
06/19/2025
P101-N GRAVITY - 1ST AND 2ND FLOOR PLANS - NORTH
BUILDING
06/19/2025
P101-S GRAVITY - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
P101-S-2 GRAVITY - 1ST FLOOR PLAN - SOUTH BUILDING -
ALTERNATE
06/19/2025
P111-N PRESSURE - 1ST AND 2ND FLOOR PLANS - NORTH
BUILDING
06/19/2025
P111-S PRESSURE - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
P111-S-2 PRESSURE - 1ST FLOOR PLAN - SOUTH BUILDING -
ALTERNATE
06/19/2025
P601 PLUMBING SCHEDULES 06/19/2025
P602-2 PLUMBING SCHEDULES - ALTERNATE 06/19/2025
P901 PLUMBING DETAILS 06/19/2025
FIRE PROTECTION SHEETSFIRE PROTECTION SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
F001 GENERAL NOTES AND LEGENDS - FIRE PROTECTION 06/19/2025
F101-N FIRE PROTECTION - 1ST AND 2ND FLOOR PLANS - NORTH
BUILDING
06/19/2025
F101-S FIRE PROTECTION - 1ST FLOOR PLAN - SOUTH BUILDING 06/19/2025
F101-S-2 FIRE PROTECTION - 1ST FLOOR PLAN - SOUTH BUILDING
- ALTERNATE
06/19/2025
SITE PLAN SHEETSSITE PLAN SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
AS101 ARCHITECTURAL SITE PLAN 06/19/2025
AS102 RAMPS ENLARGED PLANS & ELEVATIONS 06/19/2025
DEMOLITION SHEETSDEMOLITION SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
AD101 DEMOLITION & EXISTING FLOOR PLAN - NORTH BUILDING 06/19/2025
AD102 DEMOLITION & EXISTING FLOOR PLAN - SOUTH BUILDING 06/19/2025
AD103 DEMOLITION & EXISTING ROOF PLAN 06/19/2025
LIFE SAFETY SHEETSLIFE SAFETY SHEETS
Sheet # Sheet Name
Sheet Issue Date
Revised Date
LS100 CODE COMPLIANCE 06/19/2025
LS101 LIFE SAFETY PLAN - NORTH BUILDING 06/19/2025
LS102 LIFE SAFETY PLAN - SOUTH BUILDING 06/19/2025
NO. DESCRIPTION DATE
Figure 308.2.1 Unobstructed
Forward Reach
This Drawing Produced by the U.S. Access Board m in m ax
510-635510
Figure 308.2.2 Obstructed High Forward Reach
This Drawing Produced by the U.S. Access Board m ax m ax
>20-25 max20 max
Figure 308.3.1 Unobstructed Side Reach
10 max m ax m in
5 11
Figure 308.3.2 Obstructed High
Side Reach
10 max m ax m ax m ax m ax
> 10-24 max(a) (b)
This Drawing Produced by the U.S. Access Board
Figure 307.2 Limits of
Protruding Objects
This Drawing Produced by the U.S. Access Board
4 max
X
X
1.
2.
3.
4.
5.
6.
7.
THIS SCHEDULE IS SHOWN AS A STANDARD TEMPLATE. ALL ITEMS MAY NOT BE USED ON THIS PROJECT. IF ANY ITEM PRESENTED ON THIS PROJECT DOES NOT COMPLY WITH THE STANDARDS ABOVE, BRING TO THE ATTENTION
OF THE ARCHITECT BEFORE INSTALLATION OF THE ITEM.
DIMENSIONS ARE TYP, UNLESS NOTED OTHERWISE. DIMENSIONS DO NOT NECESSARILY SHOW ALL THE DEVICES
THAT ARE LOCATED ON THE WALLS.
PROVIDE ADEQUATE BLOCKING AT ALL ACCESSORY & EQUIPMENT LOCATIONS.
ALL TOILET ACCESSORIES TO BE INSTALLED BY GC UNLESS NOTED OTHERWISE. GC TO COORDINATE OWNER
FURNISHED ITEMS.
SEE THE PLANS FOR ALL ADDITIONAL TOILET ACCESSORIES & ACTUAL ROOM DIMENSIONS.
ALL TOILET ACCESSORIES TO BE INSTALLED PER MANUFACTUER'S WRITTEN INSTRUCTIONS.
REFER TO ID SERIES FOR ALL TOILET WALL FINISHES
CONTROL WALL
" M
IN
" M
AX
"M
AX
"M
AX
18" 60" MIN LONG
HOSE
CLOCK TV BRACKET
TV
FF
FF
SEAT COVER
DISPENSER
DOUBLE
TOILET
TISSUE
SANITARY
NAPKIN
DISPOSAL
(SURFACE MTD)
GRAB BARPAPER TOWEL
DISPENSER
(SURFACE MTD)
PAPER TOWEL
DISPENSER
(SURFACE MTD)
PAPER TOWEL
DISPENSER
(AUTOMATIC)
"35 "43
48" GRAB BAR
"L" SHAPED GRAB BAR
42" GRAB BAR
SOAP
DISPENSER
TO
S
PO
UT
18"
@ SIDEWALL
OF LAV
HORIZONTAL BABY
CHANGING STATION
FRAMED
MIRROR
ROBE/ COAT
HOOKS
TO
R
EF
LE
C
TI
VE
SU
FA
C E
" M
IN
" M
AX
SPECIMEN
PASS-THRU
FULL HEIGHT
MIRROR
SHOWER
CURTAIN
ROD
TO
EF
LE
C
TI
VE
SU
FA
C E
6"
FIRE EXTINGUISHER
CABINET
TO
H
AN
D
LE
O
AS
EQ
D
B Y
FI
R
E M
AR
SH
AL 80
FIRE ALARM AUDIBLE
& VISUAL SIGNAL
MED GAS
ALARM PANEL
CHALK BOARD, TACK BOARD OR
DRY ERASE BOARD
POWER
DEVICES/ OUTLETS
" DUPLEX
TELE/
DATA
DESK
INTERCOM
THERMOSTAT
MANUAL FIRE
ALARM
DEVICES/ OUTLETS
@ COUNTERTOP
2"3"
LIGHTING
CONTROLS
TYP JANITOR CLOSET
BROOM & MOP
HOLDER STRIP
EQ EQ
MOP SINK
12"
VACUUM
BREAKER
HIGHEST OPERABLE PART OF ALL CONTROLS,
TELEPHONES, DISPENSERS, ALARMS & ALL
OTHER OPERABLE EQUIPMENT - WHEN
UNOBSTRUCTED
FORWARD
REACH
SIDE
REACH
"M
AX
"M
AX
ACCESSIBLE BI-LEVEL WATER COOLER
CODE REQUIRED CLEARANCES
TY
P
15"
30" x 48"
CLR FLR SPACE
DRINKING FOUNTAINS & WATER
COOLERS. NOTE: EQUIPMENT
PERMITTED IN SHADED AREA
MI
N9" 27 "M
IN
T.
O.
S
PO
UT
"M
AX
17"-19"
RE
FE
R
TO
P
LA
NS
TO
T
OP
" M
AX
CL
R
FF
MIN
11"
MIN
8"
ST
AN
DI
NG
H T
" T .O . S
PO
UT
A1 A2 A3 B
C2
C3
C5
D E F G J M1 M2 P R1
H
MOP
SINK
FAUCET
TO
O
PE
R
AT
E
3. WALKING PARALLEL TO WALL1. SIDE REACH DIMENSIONS 2. FORWARD REACH DIMENSIONS 4. H.C. RAILING
�1 1/4" ⌀ - 1 1/2" ⌀
(CLEAR)
�1 1/2" MIN.
THESE TYPICAL MOUNTING HEIGHTS SHALL BE USED UNLESS OTHERWISE NOTED
" A .F .F . M
AX
E ADA CLEARANCES
ROLL IN SHOWER PLAN
CONTROL
AREA
HAND-HELD
SHOWER
U-SHAPE
GRAB BAR
4'- 6"
S
TD
S
TD TO
V
AN
IT
Y
LIG
HT
7'- 0"
EQ EQ
C5
D
F
E
C2
A1
M1
B
" M
AX
MIN.
3'-0"
S
TD
U.N.O 1'-5"
K1 K2
A
DA
A
DA
C
HI
LD
A
DA
ACCESSIBLE STALL
NO "D" @ MALE TLTS
STANDARD STALL
NO "D" @ MALE TLTS
URINALS
T1 - STD TOILET
60" X 60" CLEAR
SPACE, TYP. IN
ADA TLT.
NOTE: PROVIDE ACCESSORY SKIRT @ UNPROTECTED ENDS OF ALL EWC'S
1'-6"
E
S2S1 T1
D
E
REF PLAN
3'-0" TYP
EQ EQ
OF
W
ET
W
AL
L
5'- 6" T O
FI
NI
SH
REF PLAN
5'-1" MIN, FIN TO FIN
OF
W
ET
W
AL
L
5'- 6" T O
FI
NI
SH
1'-6"
CLR OPNG
34" MIN
4" MAX
C2
C5
1'- 3"
1'- 3"
1'- 8"
1'- 8"
1'- 3"
1'- 3"
E
D
C5
C2
S1 SYMBOL INDICATES STALL LAYOUT TYPE T1 SYMBOL INDICATES TOILET LAYOUT TYPE U1 SYMBOL INDICATES URINAL LAYOUT TYPE EW SYMBOL INDICATES ELECT WATER COOLER LAYOUT TYPE
30" MIN
3'-0" STD
36" MIN.
3'-0"
1'-6"
REF PLAN
3'-0"
EQ EQ
X >2 4"
REF PLAN
36" MIN
ALCOVE URINAL
AP
PR
OA
CH
3'- 1"
LA
TC
H
AP
PR
OA
CH
" H
IN
GE
A1
L2
1'-6"
REF PLAN
2'-6" MIN
LAVATORIES
1'-6"
K2
K1
K1
TYP
K1
B
U2
URINALS
3'-0" 3'-0"
36" MIN.
3'-0"
K2
TYP
MIN
1'-6"
MA
X
2'- 0"
AT
A
LC
O
VE
ADA
30" X 48"
CLR FLR
SPACEIF
APPLICABLE
U3 U4SHOWN ADD 1 U1 @ 36" O.C.
1'- 3"
1'- 3"
1'- 8" D
NOTE: NO
OBSTRUCTIONS /
DISPENSERS
ALLOWED AT
PLUMBING WALL,
WITHIN THE FLR
AREA
U1
EWC'S
EW
BOTTLE
FILLER
M1B
LAVATORIES
A1
1'-8"
MIN
1'-4"
L1
F
FF
M1M1
B
A1
30" X 48"
LAVATORY
CLEAR SPACE,
LV2 TYP.
1'- 0"
1'- 0"
2'- 5"
1'-0"
NO "D" @ MALE TLTS
1'-0"
2'- 5"
1'- 0"
NOTE: REFER TO PLUMBING SHEETS FOR FIXTURE DESIGNATIONS
15" MIN.
1'-6"
REF. PLAN
3'-0"
8 STATE OF
FLORIDA
5039RA TCETI HCRA DERE
TSI
GE
R
CIL 72
DI
EDROIRETNI
RENGIS
SM
AI
LLIWLEAHCIMNIVEK
PROJECT NO:
DATE:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
SEE SHEETS G001/G002 FOR
GENERAL NOTES APPLICABLE TO
THE ENTIRE DRAWING SET
6/
/2
:2 8:
A
M
Au to de sk
D oc s:
//W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t/4
W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t_ Ba se B id .rv t
G002
TYPICAL TOILET &
SPECIALTY EQUIPMENT
INFORMATION
40-24105
W A R
EH
O U
SE
C O N
VE
R
SI
O N T O C
LE
R K O F C O U R T
R
EC
O R D S
C
IT
Y O
F
FO
R T
M
YE
R S
06/19/2025
PERMIT DOCUMENTS
S
EC
O N
D S
TR
EE
T
FO
R T
M
YE
R S, F L
SPECIALTY EQUIPMENT AND MOUNTING HEIGHTS SPECIALTY EQUIPMENT GENERAL NOTES
TYP. FIXTURE MOUNTING HEIGHT DIAGRAM
MARK DESCRIPTION MODEL NUMBER REMARKS
A1 PAPER TOWEL DISPENSER (SURFACE) PROVIDED BY OWNER FINISH -SS (SATIN)
A2 PAPER TOWEL DISPENSER (SURFACE) PROVIDED BY OWNER FINISH -SS (SATIN)
A3 PAPER TOWEL DISPENSER
(AUTOMATIC)
B SOAP DISPENSER PROVIDED BY OWNER
C1 36" GRAB BAR BOBRICK #B-5806-36" FINISH -SS (SATIN)
C2 42" GRAB BAR BOBRICK #B-5806-42" FINISH -SS (SATIN)
C3 24" GRAB BAR BOBRICK #B-5806-24" FINISH -SS (SATIN)
C4 18" VERTICAL GRAB BAR BOBRICK #B-5806-18" FINISH -SS (SATIN)
C5 48" GRAB BAR BOBRICK #B-5806-48" FINISH -SS (SATIN)
D SANITARY NAPKIN DISPOSAL
(SURFACE)
BOBRICK #B-270 FINISH -SS (SATIN)
E DOUBLE TOILET TISSUE HOLDER W/
SHELF
BOBRICK #B-2840 FINISH -SS (SATIN)
F SEAT COVER DISPENSER BOBRICK #B-221 FINISH -SS (SATIN)
G ROBE HOOK BOBRICK #B-76717 FINISH -SS (SATIN) MOUNT ON BACK OF DOORS @
ALL OFFICES, TLT & SHWR ROOMS
H BROOM & MOP HOLDER STRIP BOBRICK #B-223- 36"
J SHOWER CURTAIN ROD BOBRICK #B-207 - VARIOUS
LENGTHS
FINISH -SS (SATIN)
M1 FRAMED MIRROR BOBRICK #B-165-2436 FINISH -SS (SATIN)
M2 FRAMED MIRROR - FULL HEIGHT BOBRICK #B-165-2460 FINISH -SS (SATIN)
P SPECIMEN PASS-THRU BOBRICK #B-505 FINISH -SS (SATIN) 6" STUD WALLS REQUIRE A
DIFFERENT MODEL
R1 HORIZONTAL BABY CHANGING
STATION
KOALA CORP KB110-SSRE
RECESSED
FINISH -SS (SATIN)
SPECIALTY EQUIPMENT SCHEDULE
TYP. TOILET FIXTURE LAYOUTS NOTE: THESE DWGS/ DESCRIPTIONS ARE FOR CODE COMPLIANCE REFERENCE AND CLARIFICATION OF DIMENSIONAL VALUES.
REFER TO PROJECT SPECIFIC ENLARGED PLANS.
NO. DESCRIPTION DATE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
A.
B.
NOT ALL PARTITION TYPES SHOWN ON THIS SHEET MAY BE USED IN
PROJECT. REFER TO PLANS FOR ACTUAL PARTITION TYPES USED.
ALL PARTITION TYPES TO BE D3s UNLESS NOTED OTHER WISE
PARTITION TYPES 'I' AND 'O' NOT USED
REFER TO PLANS AND WALL PARTITION LEGEND FOR RATED
PARTITIONS.
ALL RATED PARTITIONS SHALL BE CONSTRUCTED FIRST, IN ORDER OF
PRIORITY (SEE WALL / PARTITION PRIORITY LEGEND BELOW).
SECONDARY PARTITIONS TO ABUT BUT NOT PENETRATE RATED WALLS
AS SHOWN IN WALL ABUTMENT DETAIL ON TYPICAL PARTITION DETAILS
SHEET.
WHERE PARTITION TYPE INDICATES GYP. BD. TO BTM. OF DECK, STOP
GYP. BD. 1/2" BELOW LINE OF STRUCTURE AND SEAL.
IF A FIRE RATED PARTITION OCCURS UNDER A STRUCTURAL MEMBER
(OR OTHER OBSTRUCTION), IT IS THE CONTRACTORS RESPONSIBILITY
TO CONTINUE THE FIRE RATING OF THE PARTITION TO THE UNDERSIDE
OF THE ROOF AND/OR FLOOR DECK
SEAL ALL PENETRATIONS (DUCTS, CONDUITS, STRUCTURE, ETC.)
THROUGH ACOUSTIC AND FIRE RATED ASSEMBLIES IN CONFORMANCE
WITH THE U.L. DESIGN TYPE, THE STC RATING, APPLICABLE FIRE CODES,
AND APPLICABLE LOCAL CODES.
BASE PROFILES DEPICTED IN WALL TYPES ARE DIAGRAMMATIC,
CONTRACTOR TO REFER TO FINISH KEY AND ENLARGED BASE DETAILS
FOR MATERIALS, CONSTRUCTION AND PLACEMENT.
REFER TO SPECIFICATIONS FOR METAL STUD GAUGE, SPACING,
BRACING AND DEFLECTION REQUIREMENTS. .
ACOUSTICAL NOTES:
PARTITIONS INDICATED IN PLAN WITH PARTITION TAG TO BE
INSTALLED W/ S.A.B (SOUND ATTENUATION BLANKETS) AS
INDICATED IN PARTITION TYPE. ADD ACOUSTICAL SEALANT AT TOPS
AND BOTTOMS OF WALLS, AND AT PENETRATIONS TO MAINTAIN STC
RATING OF PARTITION TYPE.
PROVIDE 2 STUDS BETWEEN PENETRATIONS (OUTLETS) ON
OPPOSITE SIDES OF PARTITIONS INDICATED TO ACHIEVE AN STC
RATING. SEAL PERIMETER OF EACH OUTLET WITH ACOUSTICAL
SEALANT AND SEAL BACK OF OUTLET BOX WITH OUTLET BOX PADS.
REFER TO G SHEETS FOR DETAILS.
GENERAL PARTITION NOTES
WALL PARTITION / PRIORITY LEGEND
PRIORITY ORDER OF
CONSTRUCTION
TWO HOUR FIRE /SMOKE BARRIER
TWO HOUR FIRE RATED BARRIER
ONE HOUR FIRE/SMOKE BARRIER
ONE HOUR FIRE RATED BARRIER
SMOKE PARTITION
NON RATED PARTITION
HIGHEST
LOWEST
**REFER TO WALL ABUTMENT DETAIL AND PARTITIONS @ EXTERIOR WALLS
DETAILS ON TYPICAL PARTITION DETAILS SHEET FOR ADDITIONAL
INFORMATION
A6s
STUD SIZE
PARTITION TYPE
SOUND
ATTENUATION
(WHERE
APPLICABLE)
TYPICAL PARTITION TAG
CONT. METAL SLOTTED
DEFLECTION TRACK,
ATTACHED TO BOTTOM OF
STEEL PURLIN / UNISTRUT
TYPE "A1"
1 5/8" MTL STUDS
TYPE "A2"
2 1/2" MTL STUDS
TYPE "A3"
3 5/8" MTL STUDS
REFER TO PLAN AREAS
FRO R-VALUE
INSULATION AS NOTED
COMPOSITE, NON-RATED PARTITION
(TO UNDERSIDE OF STRUCTURE)
TEMPERATURE / SOUND
ATTENUATION BLANKETS
AS NOTED ON PLANS OR
AT SOUND ATTENUATION
WALLS
TYPE "A6"
6" MTL STUDS
TYPE "A8"
8" MTL STUDS
W/ SOUND ATTENUATION
TYPE "A3s"
3 5/8" MTL STUDS
TYPE "A6s"
6" MTL STUDS
TYPE "A8s"
8" MTL STUDS
TYPE 'A'
CEILING RE:
REFLECTED CEILING
PLAN
GYP BOARD TO
STRUCTURE, BOTH
SIDES
ROOF PANELS / DECK
RE: EXIST. - V.I.F.
ACOUSTICAL SEALANT AT
SOUND ATTENUATED
WALLS
MINERAL WOOL INSULATION
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY &
FINISH PLAN
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL
FINISH MATERIALS
SMOKE RATED @
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
STEEL UNISTRUT
RUNNER
BETWEEN PURLINS @
48" O.C.
U.L. - U# 419
STC W/ S.A.B: 49
TYPE "B3"
3 5/8" MTL STUDS
TYPE "B6"
6" MTL STUDS
TYPE "B8"
8" MTL STUDS
TYPE 'B'
CEILING RE:
REFLECTED CEILING
PLAN
CONT. FIRE RATED SEALANT
AT SLAB
BASE, RE: FINISH KEY &
FINISH PLAN
CONT. METAL SLOTTED
DEFLECTION TRACK,
ATTACHED TO BOTTOM OF
STRUCTURE
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
GYP BOARD TO
STRUCTURE, BOTH
SIDES
ROOF PANELS / DECK
RE: EXIST. - V.I.F.
CONT FIRE RATED
SEALANT
MINERAL WOOL INSULATION
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL
FINISH MATERIALS
W/ SOUND ATTENUATION
TYPE "B3s"
3 5/8" MTL STUDS
TYPE "B6s"
6" MTL STUDS
TYPE "B8s"
8" MTL STUDS
1HR FIRE/SMOKE @
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
U.L. - U# 465
ROOF INSULATION
OVER HVAC / AC AREAS
MI
N6"
MTL STUD BRACING
@ 48" O.C. MAX,
VERIFY W/ STUD MFG
TO VERIFY LIMITING
HEIGHT
TYPE "D1"
1 5/8" MTL STUDS
TYPE "D2"
2 1/2" MTL STUDS
TYPE "D3"
3 5/8" MTL STUDS
NON-COMPOSITE, BRACED @ 48"
O.C. NON-RATED PARTITION
TYPE "D6"
6" MTL STUDS
TYPE "D8"
8" MTL STUDS
W/ SOUND ATTENUATION
TYPE "D3s"
3 5/8" MTL STUDS
TYPE "D6s"
6" MTL STUDS
TYPE "D8s"
8" MTL STUDS
TYPE 'D'
CEILING RE:
REFLECTED CEILING
PLAN
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY &
FINISH PLAN
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
GYP BOARD, BOTH SIDES
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL
FINISH MATERIALS
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
36"MIN.
S.A.BLANKETS
36" MIN.
S.A.BLANKETS
MID-HT
FIRESTOP
TYP.
MTL STUD BRACING
@ 48" O.C. MAX,
VERIFY W/ STUD MFG
TO VERIFY LIMITING
HEIGHT
MI
N6"
TYPE "E1"
1 5/8" MTL STUDS
TYPE "E2"
2 1/2" MTL STUDS
TYPE "E3"
3 5/8" MTL STUDS
NON-COMPOSITE, BRACED @ 48" O.C. NON-RATED
PARTITION. GYP ONE SIDE.
TYPE "E6"
6" MTL STUDS
TYPE "E8"
8" MTL STUDS
W/ SOUND ATTENUATION
TYPE "E3s"
3 5/8" MTL STUDS
TYPE "E6s"
6" MTL STUDS
TYPE "E8s"
8" MTL STUDS
TYPE 'E'
CEILING RE:
REFLECTED CEILING
PLAN
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY &
FINISH PLAN
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
GYP BOARD, ONE SIDE
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL
FINISH MATERIALS
ROOM SIDE
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
36"MIN.
S.A.BLANKETS
STEEL UNISTRUT
RUNNER
BETWEEN PURLINS
@ 48" O.C.
MID-HT
FIRESTOP
TYP.
TYPE "G1"
1 5/8" MTL STUDS
TYPE "G2"
2 1/2" MTL STUDS
TYPE "G3"
3 5/8" MTL STUDS
NON-COMPOSITE, NON-RATED
PARTITION; GYP ONE SIDE
TYPE "G6"
6" MTL STUDS
TYPE "G8"
8" MTL STUDS
W/ SOUND ATTENUATION
TYPE "G3s"
3 5/8" MTL STUDS
TYPE "G6s"
6" MTL STUDS
TYPE "G8s"
8" MTL STUDS
TYPE 'G'
CONT. METAL SLOTTED
DEFLECTION TRACK,
ATTACHED TO BOTTOM OF
STRUCTURE
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS -
REFER TO PLANS
CEILING RE:
REFLECTED CEILING
PLAN
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY &
FINISH PLAN
GYP BOARD, ONE SIDE
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL
FINISH MATERIALS
ROOM
SIDE
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
MI
N.6"
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
36"MIN.
S.A.BLANKETS
STEEL UNISTRUT
RUNNER
BETWEEN PURLINS
@ 48" O.C.
CEILING RE:
REFLECTED CEILING
PLAN
TYPE "K8"
EXISTING 8" CMU BLOCK
TYPE 'K'
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
GROUTING AND REINFORCING,
RE: STRUCTURAL
CEILING RE:
REFLECTED CEILING
PLAN
TYPE 'F'
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
TYPE "F1"
1 5/8" MTL STUDS
NON-COMPOSITE, NON-RATED
PARTITION
GYP BOARD, ONE SIDE
3/8" AIR GAP
1 1/2" RIGID INSULATION
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY &
FINISH PLAN
MI
N.6"
1 5/8" METAL STUD
EXISTING CMU WALL TO
REMAIN
8 STATE OF
FLORIDA
5039RA TCETI HCRA DERE
TSI
GE
R
CIL 72
DI
EDROIRETNI
RENGIS
SM
AI
LLIWLEAHCIMNIVEK
PROJECT NO:
DATE:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
SEE SHEETS G001/G002 FOR
GENERAL NOTES APPLICABLE TO
THE ENTIRE DRAWING SET
6/
/2
:2 8:
A
M
Au to de sk
D oc s:
//W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t/4
W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t_ Ba se B id .rv t
G003
PARTITION TYPES
40-24105
W A R
EH
O U
SE
C O N
VE
R
SI
O N T O C
LE
R K O F C O U R T
R
EC
O R D S
C
IT
Y O
F
FO
R T
M
YE
R S
06/19/2025
PERMIT DOCUMENTS
S
EC
O N
D S
TR
EE
T
FO
R T
M
YE
R S, F L
NO. DESCRIPTION DATE
1/2
6 1 /2"
FINISH CEILING SEE ROOM FINISH SCHEDULE
STRUCTURE
FINISH FLOOR (SEE SCHEDULE)
FASTEN STUDS TO TRACK ON EACH SIDE
BOTTOM TRACK
FASTEN TO SLAB AT 24" O.C. WITH 5/32"
MIN POWDER DRIVEN FASTENERS
WALL BASE
(SEE SCHEDULE)
METAL STUD FRAMING AT 16" O.C.
WITH 5/8" GYP BOARD
UNLESS NOTED OTHERWISE (SEE WALL TYPES)
PROVIDE APPROVED 1/2" DEFLECTION TOP TRACK
METAL STUD BRACING
ALTERNATE DIRECTION AT 4'-0" O.C. TYP
SEE BRACING DETAIL THIS SHEET
EXISTING STEEL - PURLINGS AND
UNISTRUTS TO GAP SPACE BETWWEEN PURLINS
CASEWORK ACCESSORY WINDOW
C
B
D
D
D
A
DOOR
H
H
E
F
I
E
F
G
SEE METAL STUD PARTITION DETAIL THIS SHEET ROOF DECK
TOP TRACK BRACING
45° ALTERNATING STUDS @ 4'-0" O.C.
(SEE DIAGONAL BRACING DETAIL THIS SHEET) OR
FULL HEIGHT STUDS TO STRUCTURE ABOVE
TOP TRACK @ 6" ABOVE CEILING OR FLOOR/ROOF DECK
ABOVE AT FIRE RATED WALLS OR AS OTHERWISE NOTED -
SEE METAL STUD PARTITION DETAIL THIS SHEET
LINE OF CEILING PER ROOM FINISH SCHEDULE
GYP BOARD WALL FINISH EXTENDS TO TOP TRACK
STUDS SHALL BE 3 5/8" (MIN) @ 16" O.C.
UNLESS NOTED OTHERWISE, SEE WALL TYPES
(REFER TO MANUF. SPAN-TABLES FOR
STUD GAUGE REQUIREMENTS)
20 Ga STUD STIFFENERS AT 24" O.C. VERTICALLY x 2'-8"
MIN EACH SIDE OF OPENING, BUT NOT AT SMALL
RETURNS / CORNER ;LOCATIONS.
CLIP FLANGE AND BEND WEB AT BOTH ENDS, ATTACH
WITH (2) #8 SCREWS EACH END
SEE STUD STIFFENER DETAIL THIS SHEET
20 Ga (U.N.O.) FLOOR TRACK
ALL STUDS SHALL BE SCREWED TO TOP AND
BOTTOM TRACKS FROM BOTH SIDES, SEE METAL
STUD PARTITION DETAIL THIS SHEET
METAL DOOR FRAME SHOWN DASHED
A ACCESSORY BACKING PLATE, SEE DETAIL 5/G004
B 20 Ga STUDS TO STRUCTURE BEHIND ALL WALL HUNG CASEWORK AND
ONE STUD PAST EACH END FOR BACKING PLATE ATTACHMENT
SEE DETAIL 4/G004
C WALL CABINETS PER ELEVATIONS SHOWN DASHED
D CABINET BACKING PLATES SHOWN DASHED, SEE DETAIL 4/G004
E FRAMING AT DOOR AND WINDOW HEAD OPENING:
3'-6" OR LESS - 20 Ga x 1 1/4" TRACKS 3'-8" TO 8'-0" MAX - DOUBLE 20 Ga x 1 1/4" STUDS AND TRACKS
SEE DETAIL 7/G004
F FRAMING AT DOOR AND WINDOW JAMBS:
(2) 20 Ga STUDS TO STRUCTURE ABOVE, SCREW THROUGH GYPSUM
BOARD TO EACH STUD AT 16" O.C. VERTICALLY EACH SIDE
G 20 Ga TRACK AT WINDOW SILL
H BACKING PLATE FOR WALL STOPS WHEN SPECIFIED, SEE DETAIL 5/G004
I ANCHOR DOUBLE STUDS TO FLOOR TRACK WITH (2) #8 SHEET METAL SCREWS
TO EACH STUD TYPICAL
J AT WALL / SOFFIT MOUNTED SCREEN MONITORS - SEE DETAIL 3/G004
J
6" 6"
6"
WALL HUNG CABINET
BACKING CHANNEL
TYPICAL
BASE CABINET
FIRST STUD PAST END OF
CASEWORK
CASEWORK ELEVATION
* COORDINATE LOCATION WITH
PRODUCT INSTALLATION DRAWINGS
BRACING CHANNEL DETAIL
FULL HEIGHT 16 GAUGE METAL
STUD TO STRUCTURE ABOVE
16 GAUGE BACKING CHANNEL OR
METAL STUD
SECURE BACKING CHANNEL
WITH 1/8" POP RIVETS OR SELF
TAPPING SCREWS
CUT OUT FLANGE TO FIT
AROUND STUDS OR CUT AND
BEND FLANGE UP AT STUD
METAL STUDS PER PLAN AND
FRAMING ELEVATION
16 GAUGE x 6" WIDE STEEL PLATE
EXTEND TO STUD BEYOND
SUPPORTED ITEM (3 MIN)
CENTERLINE OF MOUNTING HEIGHT
CALL OUT FOR ELEVATIONS
(2) #8 SHEET METAL SCREWS TO EACH
STUD, TYPICAL
NOTES:
1. THIS CONDITION SHALL NOT BE USED FOR BACKING BEHIND CASEWORK,
HANDICAP GRAB BARS, OR SIMILAR ITEMS.
2. TO BE USED FOR ACCESSORIES WEIGHING LESS THAN 25 LBS.
3. MORE THAN ONE BACKER PLATE MAY BE REQUIRED PER ACCESSORY,
VERIFY MANUFACTURER'S MOUNTING REQUIREMENTS.
METAL STUDS PER PLAN AND FRAMING
ELEVATION
20 GAUGE STUD STIFFENER
CLIP FLANGES AT STUD BEHIND
WEB UP AT BOTH ENDS
SECURE STUD STIFFENER WITH (2)
#8 SELF TAPPING SCREWS
(2) 1 1/4" x 20 Ga TRACK TOP AND BOTTOM
(2) 20 Ga METAL STUDS
#8 SHEET METAL SCREWS @ 6" O/C TOP
AND BOTTOM STAGGERED
NOTES:
1. CONNECT TO STRUCTURAL MEMBER WHERE POSSIBLE.
2. 45° MIN ANGLE OF BRACING TO VERTICAL.
45° MIN
45° MIN
16 GAUGE TRACK WELDED TO
DECK WITH LEGS BENT TO
BRACE ANGLE
3 5/8" METAL STUDS (20 Ga MIN)
BRACING AT 4'-0"
16 GAUGE TRACK WELDED TO
STRUCTURAL MEMBER WITH
LEGS BENT TO BRACE ANGLE
3 5/8" METAL STUDS (20 Ga MIN)
BRACING AT 4'-0"
(2) FULL HT 16 Ga
METAL STUDS TO
STRUCTURE ABOVE
16 Ga BACKING CHANNEL
OR STUD
SECURE BACKING
CHANNEL W/ 1/8" POP
RIVET OR SELF TAPPING
SCREWS TO EACH STUD
CUT OUT FLANGE TO
FIT STUDS OR CUT
OR BEND FLANGE UP
AT STUD
COORD BACKING
CHANNEL OR STUD
WITH MONITOR
MOUNTING BRACKET
NOTE:
1. CHANNEL TO EXTEND ACROSS A MINIMUM , OF THREE STUDS
2. AT SOFFIT MOUNTED MONITORS PROVIDE HORIZONTAL AND
DIAGONAL BRACING AT EACH STUD.
3/4" PLYWOOD SHEATHING
24" X 24"
8 STATE OF
FLORIDA
5039RA TCETI HCRA DERE
TSI
GE
R
CIL 72
DI
EDROIRETNI
RENGIS
SM
AI
LLIWLEAHCIMNIVEK
PROJECT NO:
DATE:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS,SPECIFICATIONS, AND ADDENDA MAY NOT
BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS, LLC.
PHASE:
ISSUED FOR
SEAL:
GRACE HEBERT CURTIS ARCHITECTS, LLC
SHEET NUMBER
SEE SHEETS G001/G002 FOR
GENERAL NOTES APPLICABLE TO
THE ENTIRE DRAWING SET
6/
/2
:2 8:
A
M
Au to de sk
D oc s:
//W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t/4
W ar eh ou se
C on ve rt to P ar ks
R ec D ep ar tm en t_ Ba se B id .rv t
G004
TYPICAL PARTITION
DETAILS
40-24105
W A R
EH
O U
SE
C O N
VE
R
SI
O N T O C
LE
R K O F C O U R T
R
EC
O R D S
C
IT
Y O
F
FO
R T
M
YE
R S
06/19/2025
PERMIT DOCUMENTS
S
EC
O N
D S
TR
EE
T
FO
R T
M
YE
R S, F L
3" = 1'-0"1 Metal Stud Partition
1/2" = 1'-0"2 Typical Interior Wall Framing Elevation
1/2" = 1'-0"4 Casework Bracing 1/2" = 1'-0"5 Accessory Backer Plate
1" = 1'-0"6 Stud Stiffener
1" = 1'-0"7 Framing at Door and Window Openings 1" = 1'-0"8 Top of Diagonal Bracing
1" = 1'-0"3 Monitor Mounting Detail
NO. DESCRIPTION DATE
January 25, 2018 Nonbearing Wall Ratings — 1/2 or 1 HR. (See Items 1, 1A, 2, 2A and 6)
Bearing Wall Rating — 1/2 HR. (See Items 3 and 6) Finish Rating — (See Item 3)
Loaded Per 2005 NDS Supplement, ASD Method, Wall Braced by Sheathing, 100% of Design Load Applied to Wall.
This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit
States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
1. Floor and Ceiling Runners — (Not shown- For the 1/2 or 1 Hour Nonbearing Wall Ratings) — For use with Item 2 - Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24 in. OC max.
1A. Framing Members*— Floor and Ceiling Runners — (Not shown, As an alternate to Item 1 - For the 1/2 or 1 Hour Nonbearing Wall Ratings) — For use with Item 2A, channel shaped, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, min depth to accommodate stud size , attached to floor and ceiling with fasteners 24 in. OC. max.
CLARKDIETRICH BUILDING SYSTEMS — CD ProTRAK DMFCWBS L L C — ProTRAK MBA METAL FRAMING — ProTRAK RAM SALES L L C — Ram ProTRAK STEEL STRUCTURAL PRODUCTS L L C — Tri-S ProTRAK
1B. Framing Members* - Floor and Ceiling Runner — (Not shown, As an alternate to Item 1 - For the 1/2 or 1 Hour Nonbearing Wall Ratings) — For use with Item 2B, proprietary channel shaped runners, min depth to accommodate stud size , attached to floor and ceiling with fasteners 24 in.
OC. max.
CALIFORNIA EXPANDED METAL PRODUCTS CO — Viper25™ Track MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper25™ Track FUSION BUILDING PRODUCTS — Viper25™ Track IMPERIAL MANUFACTURING GROUP INC — Viper25™ Track
1D. Framing Members*— Floor and Ceiling Runners — (Not shown, As an alternate to Item 1 - For the 1/2 or 1 Hour Nonbearing Wall Ratings) — For use with Item 2E , channel shaped, fabricated from min. 0.018 in. (min bare metal thickness) galvanized steel, min depth to accommodate stud size , attached to floor and ceiling with fasteners 24 in. OC. max.
STEEL INVESTMENT GROUP L L C — AlphaTRAK
2. Steel Studs — (For the 1/2 or 1 Hour Nonbearing Wall Ratings) Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min. 3-5/8
in. deep, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height.
2A. Framing Members*— Steel Studs — (Not shown, As an alternate to Item 2- For the 1/2 or 1 Hour Nonbearing Wall Ratings) — channel shaped studs, min. 3-5/8 in. deep, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, spaced a max of 24 in. OC. Studs to be cut 3/4
in. less than assembly height.
CLARKDIETRICH BUILDING SYSTEMS — CD ProSTUD DMFCWBS L L C — ProSTUD MBA METAL FRAMING — ProSTUD RAM SALES L L C — Ram ProSTUD STEEL STRUCTURAL PRODUCTS L L C — Tri-S ProSTUD
2B. Framing Members* - Steel Studs — (Not shown, As an alternate to Item 2- For the 1/2 or 1 Hour Nonbearing Wall Ratings) - Proprietary channel shaped studs, 3-5/8 in. deep spaced a max of 24 in. OC. Studs to be cut 3/4 in less than the assembly height CALIFORNIA EXPANDED METAL PRODUCTS CO — Viper25™ MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper25™ FUSION BUILDING PRODUCTS — Viper25™ IMPERIAL MANUFACTURING GROUP INC — Viper25™
2C. Framing Members*— Steel Studs — (Not shown, As an alternate to Item 2- For the 1/2 or 1 Hour Nonbearing Wall Ratings) — channel shaped studs, min. 3-5/8 in. deep, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, spaced a max of 24 in. OC. Studs to be cut 3/4
in. less than assembly height.
TELLING INDUSTRIES L L C — TRUE-STUD™
2D. Framing Members* - Steel Studs — (As an alternate to Item 2- For the 1/2 or 1 Hour Nonbearing Wall Ratings) - For use with Item 1 (3-5/8 in.
wide track), channel shaped studs, fabricated from min 25 MSG corrosion-protected steel, 1-1/4 in. wide by 3-5/8 in. deep, spaced a max of 24 in.
OC. Studs to be cut 3/8 to 3/4 in. less than assembly height.
MARINO/WARE, DIV OF WARE INDUSTRIES INC — StudRite™
2E. Framing Members*— Steel Studs — (Not shown, As an alternate to Item 2- For the 1/2 or 1 Hour Nonbearing Wall Ratings) — channel shaped studs, min. 3-5/8 in. deep, fabricated from min. 0.018 in. (min bare metal thickness) galvanized steel, spaced a max of 24 in. OC. Studs to be cut 3/4
in. less than assembly height.
STEEL INVESTMENT GROUP L L C — AlphaSTUD
3. Wood Studs — (Not shown, As an alternate to Items 1 and 2- For the 1/2 Bearing Wall Rating) - Nom 2 by 4 in. spaced 16 in. OC max, effectively firestopped. When wood studs are used, Finish Rating is 16 Min.
4. Batts and Blankets* — (Optional, not shown) — Placed in stud cavities, any glass fiber or mineral wool insulation bearing the UL Classification Marking as to Surface Burning Characteristics and/or Fire Resistance. See Batts and Blankets (BKNV or BZJZ) Categories for names of Classified companies.
5. Furring Channels — (Optional, not shown, for single or double layer systems) — Resilient furring channels fabricated from min 25 MSG corrosion-protected steel, spaced vertically a max of 24 in. OC. Flange portion attached to each intersecting stud with 1/2 in. long Type S-12 steel screws for steel studs and 1 in. long Type S screws for wood studs.
6. Gypsum Board* — 5/8 in. thick paper surfaced, with beveled, square, or tapered edges, applied either horizontally or vertically. Vertical joints in adjacent layers (multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by steel framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge joints and horizontal butt joints in adjacent layers need not be staggered.
1/2 Hour Bearing Rating On Wood Studs - Single layer secured with 1-5/8 in. long Type S steel screws spaced 12 in. OC at the perimeter and in the field.
1/2 Hour Nonbearing Rating On Steel Studs - Single layer secured with 1 in. long Type S steel screws spaced 8 in. OC at the perimeter and 8 in.
OC in the field.
1 Hour Nonbearing Rating On Steel Studs - Base layer boards secured with 1 in. long Type S steel screws spaced 16 in. OC at the perimeter and 16 in. OC in the field. Face layer boards secured with 1-5/8 in. long Type S steel screws spaced 16 in. OC at the perimeter and 16 in. OC in the field.
When joints are aligned, screws are offset 8 in. between layers.
CGC INC — 5/8 in. thick Type FC30 UNITED STATES GYPSUM CO — 5/8 in. thick Type FC30 USG MEXICO S A DE C V — 5/8 in. thick Type FC30
7. Joint Tape and Compound — Vinyl or casein, dry or premixed joint compound applied in two coats to joints and screw heads of outer layers.
Paper tape, nom 2 in. wide, embedded in first layer of compound over all joints of outer layer panels. Paper tape and joint compound may be omit
Design No. U407Design No. U407
1. Floor or Wall Assembly — Min 3-3/4 in. (95 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete floor or wall.