CFM_Parks_and_Rec_-_Civil_Plans_-_North_Parcel.pdf

PDF 18 MB Posted

Attached to
Michigan Avenue Warehouse Renovation
Solicitation number
ITB 25-098
Issued by
Lee County, Fruitville CDP, Florida

About this file

These construction plans detail the City of Fort Myers Parks & Recreation and Clerk of Court Records Facility project, located in Section 18, Township 44 South, Range 25 East in Lee County, Florida. The proposed facility will be situated on a 1.88-acre site zoned as Civic (CI), with the project encompassing a records storage building and a parks and recreation facility. The construction plans, prepared by RESPEC Company LLC, include comprehensive documentation such as site layout, utility plans, grading and drainage specifications, erosion control measures, and detailed engineering drawings. The project involves demolishing existing structures, installing new utilities, creating parking areas, and constructing a new municipal facility.

The project includes 17 on-site parking spaces (including 5 handicap spaces), with an additional 63 staff parking spaces planned for an off-site location. The facility will have approximately 17,430 square feet of space, with a floor elevation of 10.2 feet. Utility provisions include water and sewer connections, electrical service, and stormwater management. Fire flow requirements have been assessed, with the City of Fort Myers confirming a fire flow of 4,998 GPM at 20 PSI. The facility will generate an estimated 38.25 cubic yards of solid waste per month, to be collected through curbside pickup. The project is designed with considerations for accessibility, stormwater control, and compliance with local zoning and building regulations.

View the file

Other files

File Type Posted
Michigan_Avenue_Warehouse_Renovation_(Addendum_#19_Revision).pdf PDF
Michigan_Avenue_Warehouse_Renovation_(Addendum_#10_Revision).pdf PDF
DIVISION_22_-_PLUMBING.pdf PDF
CFM_Parks_and_Rec_-_Landscape_Plans_-_South_Parcel.pdf PDF
DIVISIONS_27_&_28_-_SECURITY_&_COMMS.pdf PDF
CoFM_Warehouse_Conversion_Parks_and_Records_Dept_Arch_Spec_Binder.pdf PDF
2024-118_-_Combined_Plumbing_-_S&S.pdf PDF
2024-118_-_CoFM_Warehouse_-_Combined_Electrical.pdf PDF
2024-118_-_Combined_Mechanical_-_S&S.pdf PDF
20250619_-_Warehouse_Convert_to_Parks_&_Rec_Department_100%_CD_KMW.pdf PDF
CFM_Parks_and_Rec_-_Tech_Specifications.pdf PDF
2025.06.19-_Exist_Warehouse_to_Parks_Rec_-_Structural_Permit_Set_SS.pdf PDF
DIVISON_26_-_ELECTRICAL.pdf PDF
DIVISON_21_-_FIRE_PROTECTION.pdf PDF
CFM_Parks_and_Rec_-_Civil_Plans_-_South_Parcel.pdf PDF
2024-118_-_Combined_Fire_Protection_-_S&S.pdf PDF
CFM_Parks_and_Rec_-_Landscape_Plans_-_North_Parcel.pdf PDF
DIVISION_23_-_HVAC.pdf PDF
SRF_SupplementaryConditions_EM_Contract_(August_2022).pdf PDF
SRF_SupplementaryConditions_Construction_Contract_(August_2022).pdf PDF
FHWA-1273_(10_23)_.pdf PDF
Notice_of_Award.docx DOCX document
2_CFR_Part_200_app_II_(up_to_date_as_of_4-28-2025).pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCATED IN SECTION 18, TOWNSHIP 44 SOUTH, RANGE 25 EAST

LEE COUNTY, FLORIDA

SHEET INDEX

CONSTRUCTION PLANS

COVER SHEET, VICINITY MAP AND INDEX

DESCRIPTION

PROJECT

LOCATION

AERIAL AND EXISTING CONDITIONS PLAN

CLEARING AND DEMOLITION PLAN

NO.

C1-N C2-N C3-N

PROJECT INFORMATION

PLANNED UNIT DEVELOPMENT

18-44-25-P1-00001.0010

ZONING

PARCEL ID

VICINITY MAP

CONSULTANTS

CITY OF FORT MYERS

2200 SECOND ST.

FORT MYERS, FL 33901

(239) 321-7459

RESPEC COMPANY LLC

1412 JACKSON ST., SUITE #1

FORT MYERS, FL 33901

(239) 418-0691

DAVID M. JONES JR. AND

ASSOCIATES, INC.

2221 McGREGOR BLVD.

FORT MYERS, FL 33901

(239) 337-5525

ENGINEER SURVEYLANDSCAPE ARCHITECT

UTILITY PROVIDERS

WATER & SEWER TELEPHONEELECTRIC

CABLE GAS FIRE DISTRICT

PARKS & RECREATION AND CLERK

OF COURT RECORDS FACILITY

COVER SHEET, VICINITY

MAP AND INDEX

METRON SURVEYING & MAPPING, LLC

10970 S. CLEVELAND AVE., SUITE 605

FORT MYERS, FL 33907

(239) 275-8575

FLORIDA POWER AND LIGHT

2425 THOMPSON ST.

FORT MYERS, FL 33901

(239) 332-9154

CENTURYLINK

2820 CARGO ST.

FORT MYERS, FL 33902

(239) 336-2008

CITY OF FORT MYERS

2033 JACKSON STREET

FORT MYERS, FL 33901

(239) 321-7311

TECO GAS

5901 ENTERPRISE PKWY.

FORT MYERS, FL 33905

(239) 690-5513

COMCAST CABLE

12641 CORPORATE LAKES DR.

FORT MYERS, FL 33913

(239) 432-1805

N

EW

S

MICHIGAN AVENUE

C1-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 1-

C O

VE

R

.D W

G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

SE

ABOARD S

TR

EE

TPA

LM

A

VE

N U

E

FIRST STREET

SECOND STREET

C4-N C5-N

C8-N C9-N

SITE LAYOUT, SIGNING AND MARKING PLAN

PAVING, GRADING, AND DRAINAGE PLAN

UTILITY PLAN

PAVING AND DRAINAGE DETAILS

CITY OF FORT MYERS DETAILS

EROSION CONTROL PLAN

C7-N C6-N

2801 MICHIGAN AVE, FORT MYERS, FL 33916ADDRESS

CONSTRUCTION INFORMATION

CALL BEFORE YOU DIG: 811

Always call 811 two full business days before you dig

REVISIONS SUMMARY

DESCRIPTIONREV. DATE REVISED SHEETS

ATTACHMENTS

LANDSCAPE AND IRRIGATION PLANS (DMJA)

3.5

3.7

3.7

4.0

4.7

5.6

3.8

4.9

5.0

8.9

8.9

.04

.04

.23

6.4

5.9

.30

7.3

7.3

8.6

8.3

8.5

7.3

8.5

7.8

6.8

7.4

7.4 05.6

6.1

6.4

7.6

6.4

5.7

7.3

5.4

4.5

3.8

4.3

5.3

5.8

2.4

2.4

2.3 1.5

3.2

1.5

3.2

3.6

1.8

3.5

3.6

2.0

4.0

4.4

4.6

3.8

2.7

5.0

4.5

4.3

2.7

4.6

4.7

5.5

5.1 54.8

5.4

5.1

5.8

7.7

.0710

.06

9.9

3.4

2.7

3.8

3.8

4.7

7.3

5.7

2.7

6.9

8.9

8.9 8.9

9.1

8.9

8.8

8.7

8.8

8.9

8.4 68.4

8.3

8.5 1 8.3

8.0

7.7

7.8 3 7.9

7.8

7.5

7.5 7.3

7.3 1 7.4

7.4

7.5

7.5

7.7

7.0

7.1

5.9

6.0

5.8

5.8

5.7

5.9

6.7

6.0

5.9

5.8

5.7

5.9

5.6

5.7

6.1

5.9

5.9

5.8

6.0

6.1 7 6.2

6.4

6.67

6.5

6.8

6.3

7.3

7.2

7.3

7.5

7.6

7.7

7.3

7.3

7.5

7.2

6.6

6.2

6.1

6.7

6.8

5.3

5.3

5.0

5.1

4.7

4.8

4.4

4.6

4.5

4.0

3.8

4.7

4.6

3.4

3.7

3.6

4.1

3.4

3.1

3.9

4.7

5.1

5.3

4.5

5.7

6.3

6.3 86.4

6.2

6.0

6.4

6.3

6.0

6.0

6.3

5.9 86.2

5.9

6.0

6.0

5.9

5.9

5.3

5.2

5.9

5.4

5.6

5.5

5.6

5.6

3.4

2.8

2.7 32.9

3.2

2.6

2.7

2.3

2.6

2.6

2.3

2.4

2.0

2.0

2.0

2.3

2.1

2.2

2.4

2.5

2.4

2.1

1.9

1.6

2.0

1.8 02.2

2.3

1.9

1.9

1.4

1.3

1.2

1.2 81.7

1.8

1.2

1.0

1.2

1.4

1.2

1.0 6 1.1

1.1

1.5

3.5

4.0

1.4

6.6

7.1

EXISTING

MULTIFAMILY

ZONED: CI

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING BUILDING

(VACANT)

EXISTING BUILDING

(VACANT)

PALM AVENUE

M

IC

H

IG

A N

A

VE

N U

E

PR

O

VID

EN

C

E STR

EET

EXISTING STORM WATER

PUMP STATION

ZONED: CIVIC

EX. WATER SERVICE

AND BACKFLOW

PREVENTOR

EXISTING VACANT

ZONED: CI

PROPERTY

BOUNDARY

PROPERTY

BOUNDARY

PROPERTY

BOUNDARY

(PUBLIC - 50' ROW)

(P U

BL

IC

' R O

W

AERIAL AND EXISTING

CONDITIONS PLAN

C2-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 2-

AE

R

IA

L.

D W

G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

N

E W

S

300 15 60

PROJECT DATUM

NAVD

DATUM CONVERSION

NAVD + 1.17 = NGVD

3.7

3.7

4.0

4.7

5.6

3.8

4.9

5.0

8.9

8.9

.04

.04

.23

6.4

5.9

.30

7.3

7.3

8.6

8.3

8.5

7.3

8.5

7.8

6.8

7.4

7.4 05.6

6.1

6.4

7.6

6.4

5.7

7.3

5.4

4.5

3.8

4.3

5.3

5.8

2.4

2.4

2.3 1.5

3.2

1.5

3.2

3.6

1.8

3.5

3.6

2.0

4.0

4.4

4.6

3.8

2.7

5.0

4.5

4.3

2.7

4.6

4.7

5.5

5.1 54.8

5.4

5.1

5.8

7.7

.0710

.06

9.9

3.4

2.7

3.8

3.8

4.7

7.3

5.7

2.7

6.9

8.9

8.9 8.9

9.1

8.9

8.8

8.7

8.8

8.9

8.4 68.4

8.3

8.5 1 8.3

8.0

7.7

7.8 3 7.9

7.8

7.5

7.5 7.3

7.3 1 7.4

7.4

7.5

7.5

7.7

7.0

7.1

5.9

6.0

5.8

5.8

5.7

5.9

6.7

6.0

5.9

5.8

5.7

5.9

5.6

5.7

6.1

5.9

5.9

5.8

6.0

6.1 7 6.2

6.4

6.67

6.5

6.8

6.3

7.3

7.2

7.3

7.5

7.6

7.7

7.3

7.3

7.5

7.2

6.6

6.2

6.1

6.7

6.8

5.3

5.3

5.0

5.1

4.7

4.8

4.4

4.6

4.5

4.0

3.8

4.7

4.6

3.4

3.7

3.6

4.1

3.4

3.1

3.9

4.7

5.1

5.3

4.5

5.7

6.3

6.3 86.4

6.2

6.0

6.4

6.3

6.0

6.0

6.3

5.9 86.2

5.9

6.0

6.0

5.9

5.9

5.3

5.2

5.9

5.4

5.6

5.5

5.6

5.6

3.4

2.8

2.7 32.9

3.2

2.6

2.7

2.3

2.6

2.6

2.3

2.4

2.0

2.0

2.0

2.3

2.1

2.2

2.4

2.5

2.4

2.1

1.9

1.6

2.0

1.8 02.2

2.3

1.9

1.9

1.4

1.3

1.2

1.2 81.7

1.8

1.2

1.0

1.2

1.4

1.2

1.0 6 1.1

1.1

1.5

3.5

4.0

1.4

6.6

7.1

S

S

S

EXISTING

MULTIFAMILY

ZONED: CI

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING WAREHOUSEEXISTING WAREHOUSE

EX. CHAIN LINK FENCE

(TO BE REMOVED)

EX. CHAIN LINK FENCE

(TO BE REMOVED)

PR

O

VID

EN

C

E STR

EET

EXISTING STORM WATER

PUMP STATION

ZONED: CIVIC

EX. CHAIN LINK FENCE

AND GATE

(TO BE REMOVED)

EX. 54" RCP EX. 18" RCP EX. 18" RCP

EX. 12" RCPEX. 12" PVC

WATER MAIN

EX. 6" PVC WATER MAIN

EX. 8" PVC

SANITARY SEWER

EX. SANITARY SEWER MANHOLE

RIM = 6.31

INV. W = -0.51

INV. S = -0.54

EX. PAVED PARKING

(TO BE REMOVED)

EX. WATER SERVICES AND

BACKFLOW PREVENTOR

REMOVED TO THE MAIN AND

ABANDONED

EX. CONCRETE RAMP

(TO REMAIN)

PROPOSED CITY OF FORT MYERS

PARKS AND RECREATION AND

CLERK OF COURT PARKING FACILITY

(SITC-043075-2024)

ZONED: CI

EX. SEPTIC TANK AND DRAIN FIELD

(TO BE REMOVED AND DISPOSED)

EX. METAL SHED

(TO BE REMOVED)

EX. CONC. RAMP

(TO REMAIN)

EX. HYDRANT

ASSEMBLY (TYP.)

(TO REMAIN)

EX. FIRE BACKFLOW

PREVENTOR

(TO REMAIN)

EX. FIRE BACKFLOW PREVENTOR

(TO REMAIN)

EX. CONC. STAIRS

AND RAMP

(TO BE REMOVED)

EX. CONTROL

STRUCTURE

(TO REMAIN)

EX. CHAIN LINK FENCE

(TO BE REMOVED)

PROPERTY

BOUNDARY

PROPERTY

BOUNDARY

PROPERTY

BOUNDARY

SAWCUT AND REMOVE

EX. ASPHALT DRIVEWAY

APRON AND EX. CONC.

SIDEWALK

SAWCUT AND REMOVE

EX. SIDEWALK

SAWCUT AND REMOVE

EX. ASPHALT FOR

UTILITY INSTALLATION

SAWCUT AND REMOVE

EX. SIDEWALK FOR

UTILITY INSTALLATION

PALM AVENUE

M

IC

H

IG

A N

A

VE

N U

E

(PUBLIC - 50' ROW)

(P U

BL

IC

' R O

W

EX. 12" RCP

EX. INLET

RIM = 6.09

INV. NE = 4.07

INV. S = 4.33EX. JUNCTION BOX

RIM = 6.21

INV. N = 2.33

INV. E = 2.60

INV. SE = 2.79

INV. SW = 2.75

EX. INLET

RIM = 5.84

INV. W = 3.20

EX. 12" RCP

EX. 18" RCP

INV. = 2.00

(TO REMAIN)

EX. 18" RCP

INV. = 2.10

(TO REMAIN)

EX. 18" DIP FORCE MAIN

SAWCUT AND REMOVE

EX. ASPHALT

REFER TO LANDSCAPE PLANS

FOR LOCATIONS OF EXISTING

TREES TO REMAIN

EX. POWER

POLE (TYP.)

CLEARING AND

DEMOLITION PLAN

C3-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 3-

D

EM

O .D

W G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

N

E W

S

300 15 60

LEGEND

ASPHALT/CONCRETE

TO BE REMOVED

LIMIT OF CLEARING AND

GRUBBING

PROJECT DATUM

NAVD

DATUM CONVERSION

NAVD + 1.17 = NGVD

STOP

PARKING BY

DISABLED

PERMIT

ONLY

FINE

$250 MAX

EXISTING

MULTIFAMILY

ZONED: CI

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING STORM WATER

PUMP STATION

ZONED: CIVIC

5' 9'

18'

R12'

R3'

R25'

R25'

R3'

24'

24" WHITE STOP BAR

R1-1 (30"x30")

FTP-20-06

FTP-22-06

PROPERTY BOUNDARY

PROPERTY BOUNDARY

PROPERTY BOUNDARY

4'

6' STANDARD CROSSWALK

(SEE PAVING DETAILS SHEET)

4'

5'

FUTURE PARK

PATCH AND SEALCOAT EX.

PAVED AREA BETWEEN

WAREHOUSES AND

DRIVEWAY APRON

15'

ADA PARKING

SPACE

12'x18'

ADA PARKING

ACCESS AISLE

5'x18'

FULL DEPTH PAVEMENT

RESTORATION

6' DECORATIVE

FENCE WITH

AUTOMATIC

SLIDING GATE

TYPE 'D' CURB

(TYP.)

PARKING BY

DISABLED

PERMIT

ONLY

FINE

$250 MAX

FTP-20-06

FTP-22-06

ADA PARKING

SPACE

12'x18'

5' ADA PARKING

ACCESS AISLE

9'18'

6" CONC. SIDEWALK

PARKS AND RECREATION

FACILITY

RECORDS STORAGE

PALM AVENUE

M

IC

H

IG

A N

A

VE

N U

E

(PUBLIC - 50' ROW)

(P U

BL

IC

' R O

W

BIKE RACK

DETECTABLE WARNING

(TYP.) REF. FDOT INDEX

522-002

R22'3'

FULL DEPTH PAVEMENT

RESTORATION

8'

R3'

R3'

STOPR1-1

(30"x30")

24" WHITE

STOP BAR

6' STANDARD CROSSWALK

(SEE PAVING DETAILS

SHEET)

FULL DEPTH PAVEMENT

RESTORATION

24'

SEE SOUTH PARCEL PLANS FOR

CONTINUATION OF SIDEWALK ALONG

MICHIGAN AVE. (SITC-043075-2024)

DO NOT

ENTERR5-1

PROPOSED CITY OF FORT MYERS

PARKS AND RECREATION AND

CLERK OF COURT PARKING FACILITY

(SITC-043075-2024)

ZONED: CI

1'

6' HIGH, GREEN VINYL COATED

CHAIN LINK FENCE

AUTOMATIC ARM

BARRIER GATE

STABILIZED GRASS ACCESS

6' STANDARD CROSSWALK

(SEE PAVING DETAILS SHEET)

6' STANDARD CROSSWALK

(SEE PAVING DETAILS SHEET)

6" CONC.

SIDEWALK (TYP.)

5'

4" CONC.

SIDEWALK (TYP.)

LIGHT POLE (TYP.)

EX. POWER

POLE (TYP.)

3' TYPE 'D' CURB

TRANSITION (TYP.)

SITE LAYOUT, SIGNING

AND MARKING PLAN

C4-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 4-

SI

TE

.D W

G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

N

E W

S

300 15 60

1. ALL CONTRACTORS AND SUB-CONTRACTORS SHALL MAINTAIN THEIR WORK AND THE SITE RELATIVE TO THEIR WORK IN ACCORDANCE WITH THE STORMWATER POLLUTION PREVENTION PLAN AND ALL REQUIREMENTS OF THE PROJECT N.P.D.E.S.

PERMIT.

2. THE CONTRACTOR SHALL BE RESPONSIBLE TO DEWATER IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL PERMITTING

REQUIREMENTS.

3. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE CITY OF FORT MYERS LAND DEVELOPMENT CODE.

4. THE CONTRACTOR SHALL RETAIN ON THE WORK SITE AT ALL TIMES COPIES OF ALL PERMITS NECESSARY FOR ANY CONSTRUCTION.

5. THE CONTRACTOR SHALL NOTIFY THE OWNER AND CONTACT ALL UTILITY COMPANIES FOR LOCATIONS OF EXISTING UTILITIES IN

THE AREA 72 HOURS (MINIMUM) PRIOR TO COMMENCING CONSTRUCTION.

6. THE LOCATION OF EXISTING UTILITIES, SIDEWALKS, PAVEMENT, VEGETATION AND MISCELLANEOUS IMPROVEMENTS ARE

APPROXIMATE. THE EXACT FIELD LOCATIONS SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD PRIOR TO COMMENCING ANY

CONSTRUCTION.

7. THE NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988 IS THE BENCHMARK DATUM FOR THIS PROJECT.

8. ANY PUBLIC LAND CORNER WITHIN LIMITS OF CONSTRUCTION IS TO BE PROTECTED. ANY LAND CORNER MONUMENT IN DANGER OF

BEING DESTROYED MUST BE PROPERLY REFERENCED BY THE CONTRACTOR.

9. EXISTING IMPROVEMENTS ON-SITE AND OFF-SITE SHALL BE RESTORED TO A CONDITION EQUIVALENT TO THAT WHICH EXISTED

PRIOR TO COMMENCING CONSTRUCTION, AT NO ADDITIONAL COST TO THE OWNER.

10. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANY DEVIATION IN

PLAN INFORMATION SHALL BE REPORTED TO THE ENGINEER AND OWNER'S REPRESENTATIVE IMMEDIATELY.

11. CONTRACTOR IS REQUIRED TO OBTAIN FROM THE ENGINEER WRITTEN APPROVAL FOR ANY DEVIATIONS FROM THE PLANS AND/OR

SPECIFICATIONS.

12. UNDERGROUND CONTRACTOR SHALL MINIMIZE THE WORK AREA AND WIDTH OF ALL TRENCHES TO AVOID DISTURBANCES OF

NATURAL VEGETATION. SPOIL FROM TRENCHES SHALL BE PLACED ONLY ON PREVIOUSLY CLEARED AREAS OR AS DIRECTED BY THE OWNER. CONTRACTOR SHALL NO REMOVE OR DISTURB ANY TREES AND/OR SHRUBS WITHOUT PRIOR APPROVAL OF THE OWNER.

13. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING TRAFFIC AND USAGE OF THE EXISTING STREETS ADJACENT TO THE PROJECT. ALL TRAFFIC MAINTENANCE CONTROL SHALL BE IN ACCORDANCE WITH FLORIDA MANUAL OF TRAFFIC CONTROL AND SAFE PRACTICES FOR STREET CONSTRUCTION, MAINTENANCE, AND UTILITY OPERATIONS. TRAFFIC CONTROL OPERATION PROCEDURES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL PRIOR TO THE BEGINNING OF CONSTRUCTION.

14. DETECTABLE WARNING PADS SHALL BE INCIDENTAL TO SIDEWALK INSTALLATION.

15. ANY EXCESS MATERIAL GENERATED FROM CONSTRUCTION ACTIVITIES MUST BE DISPOSED OF BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE OWNER.

GENERAL DEVELOPMENT NOTES: SIGNING AND MARKING NOTES:

1. ALL SIGNING AND PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE F.D.O.T. STANDARDS FOR ROAD AND BRIDGE

CONSTRUCTION, LATEST EDITION, THE F.D.O.T. ROADWAY AND TRAFFIC DESIGN STANDARDS, LATEST EDITION, THE MANUAL ON

UNIFORM TRAFFIC CONTROL DEVICES AND PUBLISHED STANDARDS.

2. ALL STOP SIGN LOCATIONS SHALL INCLUDE A 24" PAINTED WHITE STOP BAR UNLESS NOTED OTHERWISE.

3. THE CONTRACTOR SHALL COMPLY WITH THE "STATE OF FLORIDA MANUAL OF TRAFFIC CONTROL AND SAFE PRACTICES FOR STREET

AND HIGHWAY CONSTRUCTION, MAINTENANCE, AND UTILITY OPERATIONS" AND WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL

DEVICES".

4. ON-SITE PAVEMENT PARKING SHALL BE PAINTED. OFF-SITE PAVEMENT MARKINGS SHALL BE THERMOPLASTIC.

PROPERTY LINE BUFFER REQUIRED

CIVIC

R.O.W.

ADJACENT USE

N.A.

BUFFER REQUIREMENTS

NORTH

EAST

WEST

USE RATIO REQUIRED PROVIDED

PARKING SUMMARY

1. "(#)" REPRESENTS THE NUMBER OF HANDICAP SPACES INCLUDED IN THE TOTAL

SPACES.

2. PARKING REQUIREMENTS PER CITY OF FORT MYERS LDC, 134.3.5.

3. 17 SPACES, INCLUDING 5 HANDICAP SPACES, ARE PROVIDED ON-SITE. 63

ADDITIONAL SPACES WILL BE PROVIDED IN THE OFF-SITE STAFF PARKING LOT.

NOTES:

TOTAL SPACES 80(5)59

80591 PER 300 SQ. FT. X 17,430 S.F.

SOUTH

CONCRETE SIDEWALK

LEGEND

ASPHALT PAVEMENT

(SEE SHEET C7-N FOR PERVIOUS

PAVEMENT OPTION)

CATEGORY PERCENTAGE

LAND USE SUMMARY

TOTAL 1.88 AC. 100%

15' TYPE 'B'

R.O.W. 15' TYPE 'B'

MULTIFAMILY 8' TYPE 'B' *

PAVEMENT / SIDEWALK 0.45 AC. 23.9%

EX. BUILDING 0.41 AC. 21.8%

OFFICE

*PER ZONING AMENDMENT PUD24-0035

PERVIOUS 1.02 AC. 54.3%

STABILIZED GRASSED ACCESS

PROPOSED

AREA

EXISTING

AREA

1.88 AC.

0.47 AC.

0.41 AC.

1.00 AC.

0.06 AC. 0.08 AC.

1. AREA INCLUDES THE IMPERIOUS SURFACES LOCATED ALONG

THE PROPERTY'S FRONTAGE ON MICHIGAN AVE., BETWEEN THE

PROPERTY BOUNDARY AND THE CENTER LINE.

NOTES:

OFF-SITE IMPERVIOUS 1

3.7

3.7

4.0

4.7

5.6

3.8

4.9

5.0

8.9

8.9

.04

.04

.23

6.4

5.9

.30

7.3

7.3

8.6

8.3 58.5

7.3

8.5

7.8

6.8

7.4

7.4 05.6

6.1

6.4

7.6

6.4

5.7

7.3

5.4

4.5

3.8

4.3

5.3

5.8

2.4

2.4

2.3

1.5

3.2

1.5

3.2

3.6

1.8

3.5

3.6

2.0

4.0

4.4

4.6

3.8

2.7

5.0

4.5

4.3

2.7

4.6

4.7

5.5

5.1 54.8

5.4

5.1

5.8

7.7

.0710

.06

9.9

3.4

2.7

3.8

3.8

4.7

7.3

5.7

2.7

6.9

7.7

7.8

7.9

7.8

7.5

7.5

7.3

7.3 1 7.4

7.5

7.5

7.7

7.0

7.1

5.9

6.0

5.8

5.8

5.7

5.9

6.7

6.0

5.9

5.8

5.7

5.9

5.6

5.7

6.1

5.9

5.9

6.3

7.3

7.2

7.3

7.5

7.6

7.7

7.3

7.3

7.5

7.2

6.6

6.2

6.1

6.7

6.8

5.3

5.3

5.0

5.1

4.7

4.8

4.4

4.6

4.5

4.0

3.8

4.7

4.6

3.4

3.7

3.6

4.1

3.4

3.1

3.9

4.7

5.1

5.3

4.5

5.7

6.3

6.3

6.4

6.2

6.0

6.4

6.3

6.0

6.0

6.3

5.9 86.2

5.9

6.0

6.0

5.9

5.9

5.3

5.2

5.9

5.4

5.6

5.5

5.6

5.6

3.4

2.8

2.7 32.9

3.2

2.6

2.7

2.3

2.6

2.6

2.3

2.4

2.0

2.0

2.0

2.3

2.1

2.2

2.4

2.5

2.4

2.1

1.9

1.6

2.0

1.8 02.2

2.3

1.9

1.9

1.4

1.3

1.2

1.2 81.7

1.8

1.2

1.1

3.5

4.0

1.4

6.6

7.1

S

S S

EXISTING MULTIFAMILY

ZONED: CI

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

PROPERTY BOUNDARY

PROPERTY BOUNDARY

PROPERTY BOUNDARY

EX. SIDEWALK

EX

. S

ID

EW

AL

K

7.60

5.98

5.885.76

5.80

7.70 7.60

8.008.10

6.64

6.64

5.92

7.92

7.42

6.16

22 LF 12"x18" ERCP

EX. 18" RCP

INV. = 2.00

7.52

8.10

F.F.E. = 10.2

AA

B B

5.90

6.00

5.80

5.90

4.163.833.813.793.77 S-4 S-3

C C

MATCH EX. GRADE

MATCH EX. GRADE

PARKS AND RECREATION FACILITYRECORDS STORAGE

PALM AVENUE

M

IC

H

IG

A N

A

VE

N U

E

(PUBLIC - 50' ROW)

(P U

BL

IC

' R O

W

CONCRETE

FLUME

RUBBLE RIP RAP

(SEE DETAIL)

4.22

F.F.E. = 10.0

5.95

MATCH EX. GRADE

4.40 4.70

5.00 5.35

3.12 3.48

3.60

4.00

4.15

3.45

2.30

2.002.10 2.00

5.005.50

EX. 18" RCP

INV. = 2.10

6.16

7.30 7.52

6.46

6.41

6.34

6.29

7.74

7.92

7.75 6.345.49

6.465.61

D D

6.18

MATCH EX.

GRADE

MATCH EX. GRADE

6.46 7.87

S-2

LF

8" H

D

PE

(H P

ST

O

R M

S-1

MATCH EX. GRADE

6.30

7.207.10

6.55 7.107.00

7.40 7.22

6.78

MATCH EX.

GRADE

6.45

6.55

6.55

6.65

5.64

BOTTOM 6" PVC SEWER SERVICE = 1.63

TOP 18" HP STORM PIPE = 1.00

NO CONFLICT

7.87

E E

2.30 2.20

EX. CONTROL STRUCTURE

GRATE ELEV. = 3.02

INV. W (10") = 1.40

BLEEDER ELEV. = 1.50

MATCH EX. GRADE

EX. POWER

POLE (TYP.)

DRAINAGE STRUCTURE TABLE

INV. (18") = 3.90

12"x18" MES

FDOT #430-021

S-4

INV. (18") = 3.95

12"x18" MES

FDOT #430-021

S-3

INV. E (18") = -0.75

GRATE ELEV. = 2.30

TYPE 'C' INLET

FDOT #425-052

MODIFIED PER DETAIL G-99

S-2

INV. W (18") = 0.50

GRATE ELEV. = 5.49

TYPE 'C' INLET

FDOT #425-052

MODIFIED PER DETAIL G-99

S-1

PAVING, GRADING, AND

DRAINAGE PLAN

C5-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 5-

PA

V-

D R

G .D

W G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

1. THE LENGTH OF ALL STORM DRAIN PIPES SHOWN ARE APPROXIMATE AND ARE

MEASURED FROM THE INSIDE FACE OF STRUCTURE TO THE INSIDE FACE OF THE

NEXT STRUCTURE.

2. EXISTING OFF-SITE DRAINAGE PATTERNS SHALL BE MAINTAINED DURING THE

COURSE OF CONSTRUCTION.

3. THE LOCATION OF THE DRAINAGE STRUCTURES SHOWN ON THE PLANS MAY BE

FIELD ADJUSTED TO PRESERVE ANY EXISTING VEGETATION, AS APPROVED BY THE

ENGINEER.

4. DURING CONSTRUCTION, ALL INLET OPENINGS SHALL BE COVERED WITH FILTER

FABRIC (MIRAFI 140N, OR APPROVED EQUAL) TO PREVENT DEBRIS FROM FALLING

INTO THE INLET.

5. THE CONTRACTOR SHALL ADJUST ALL PROPOSED ELEVATIONS TO MEET THE

EXISTING GRADES AS NEEDED.

6. ALL STORM DRAINAGE PIPE SHALL BE REINFORCED CONCRETE PIPE (RCP), UNLESS

OTHERWISE NOTED.

7. PROPOSED GRADES IN OPEN SPACE AREAS ARE TOP OF SOD.

8. A PORTION OF THE SUBJECT PARCEL IS LOCATED IN FLOOD ZONE 'AE' HAVING A

BASE FLOOD ELEVATION OF 9.0 NAVD AND FLOOD ZONE 'X' BASED ON FLOOD

INSURANCE RATE COMMUNITY PANEL 12071C0288H, NOVEMBER 17, 2022.

9. THERE ARE NO KNOWN IMPACTS TO SURFACE GROUND WATER RESULTING FROM

THE PROJECT.

10. ALL ELEVATIONS PROVIDED ARE BASED IN NAVD DATUM.

11. PIPE JOINTS SHALL BE WRAPPED IN MIRAFI FABRIC UPON INSTALLATION.

GENERAL DRAINAGE NOTES:

ASPHALT PAVEMENT

CONCRETE SIDEWALK (SEE DETAIL)

LEGEND

N

E W

S

200 10 40

PROJECT DATUM

NAVD

4" CONC. SIDEWALK

PROPERTY

BOUNDARY

15' R.O.W. BUFFER

EX. MICHIGAN

AVENUE R.O.W.

12' 12' 18' PARKING SPACE

4' - 5'

(SEE

PLANS) 7' BUILDING

F.F.E. = 10.2

TYPE 'D' CURB

PARKING

0.67'

PROPERTY

BOUNDARY

15' R.O.W. BUFFER

2'

EX. PALM AVE

R.O.W.

SILT FENCE

MATCH EX. GRADE

ELEV. = 5.85±

TOP OF BANK

ELEV. = 6.16 TO 6.38

SECTION B-B

NTS

1'

SILT FENCE

SECTION A-A

NTS

2% 1% 2%1%

PROPERTY

BOUNDARY

15' R.O.W. BUFFER

2'

EX. PALM AVE

R.O.W.

SILT FENCE

MATCH EX. GRADE

ELEV. = 4.50 TO 5.35±

SECTION C-C

NTS

6.5' 6.5'

BUILDING

F.F.E. = 10.2

10.8'

SWALE

ELEV. = 3.85 TO 3.77

TOP OF BANK

ELEV. = 5.55 TO 5.85

3:1 MAX 3:1 MAX

6.5' 6'

SWALE

ELEV. = 4.16 TO 4.38

3:1 MAX 3:1 MAX

SECTION E-E

NTS

5'18' PARKING

1'

MATCH EX. EDGE

OF PAVEMENT

8' BUFFER

6'

SECTION D-D

NTS

2%

SILT FENCE

2'6'

2%

6' 3' BUILDING

F.F.E. = 10.20.67'

4:1 MAX

MATCH EX. GRADE

ELEV. = 6.15 TO 7.31±

1'

6' FENCE

PROPERTY

BOUNDARY

STABILIZED GRASSED ACCESS

F.F.E. = 10.2F.F.E. = 10.0

EX. ELEV. VARIES

(5.44 - 5.94)

EX. ELEV. = ± 5.29

(ROUTED WEST TO

EX. DETENTION

AREA)

EX. ELEV. = ± 6.38

EX. BUILDING

EX. BUILDING EX. PAVED AREA

±32' ±80.4'

STAIRS /

RAMP

S

S

S S

EXISTING

COMMERCIAL

ZONED: CI

EXISTING STORM WATER

PUMP STATION

ZONED: CIVIC

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

EXISTING SINGLE FAMILY

ZONED: RS-7

PARKS AND RECREATION

FACILITY

RECORDS STORAGE

EX. SANITARY SEWER

MANHOLE (TYP.)

EX. 2" GP

WATER MAIN

EX. 12" PVC

WATER MAIN

EX. 6" PVC WATER MAIN

EX. HYDRANT

ASSEMBLY (TYP.)

EX. FIRE BACKFLOW

PREVENTOR

EX. FIRE BACKFLOW

PREVENTOR

CONTRACTOR TO

DEFLECT EX. 2" WATER

MAIN AS NEEDED

143 LF 6" PVC

SEWER SERVICE

@ 1.04% MIN.

6" PVC SEWER SERVICE

INV. = 2.50

MH-1

RIM = 5.5

INV. N (6") = 0.67

INV. E (6") = 1.50

INV. S (8") = 0.57

6" PVC SEWER SERVICE

INV. = 2.50

6" CLEANOUT

INV. = 1.39 185 LF 8" PVC

(SDR26) SANITARY

SEWER @ 0.4%

12"x2" SERVICE SADDLES

W/ 2" WATER SERVICES

2" TEE

2" GATE VALVE

2" SCH 80 PVC WATER

SERVICE (TYP.)

1 1/2" POTABLE WATER

METER AND BACKFLOW

PREVENTOR

1 12 " IRRIGATION METER

AND BACKFLOW

PREVENTOR

PALM AVENUE

M

IC

H

IG

A N

A

VE

N U

E

(PUBLIC - 50' ROW)

(P U

BL

IC

' R O

W

EX. 8" PVC

SANITARY SEWER

EX. SANITARY SEWER MANHOLE

INV. E (8") = -0.44 (CORE)

RIM = 6.31

INV. W = -0.51

INV. S = -0.54

EX. INLET

RIM = 6.09

INV. NE = 4.07

INV. S = 4.33

EX. JUNCTION BOX

RIM = 6.21

INV. N = 2.33

INV. E = 2.60

INV. SE = 2.79

INV. SW = 2.75

EX. INLET

RIM = 5.84

INV. W = 3.20

MH-2

INV. N (8") = -0.16

INV. W (8") = -0.26

BOTTOM EX. 12" RCP = 2.46

TOP 8" PVC SEWER = 0.33

NO CONFLICT

42 LF 8" PVC

(SDR26) SANITARY

SEWER @ 0.4%

EX. 18" RCP

INV. = 2.00

EX. 18" RCP

INV. = 2.10

6" CLEANOUT

INV. = 2.17

6" PVC SEWER SERVICE

INV. = 2.50

INV. = 0.29

EX. 18" DIP

FORCE MAIN

BOTTOM 6" PVC SEWER SERVICE = 1.63

TOP 18" HP STORM PIPE = 1.00

NO CONFLICT

PROPOSED CITY OF FORT MYERS

PARKS AND RECREATION AND

CLERK OF COURT PARKING FACILITY

(SITC-043075-2024)

ZONED: CI

UTILITY PLAN

C6-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 6-

U

TI

LI

TY

.D W

G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

N

E W

S

300 15 60

1. CONTRACTOR TO VERIFY THE SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO

COMMENCING ANY CONSTRUCTION.

2. LOCATIONS OF PROPOSED UTILITY LINES ARE SUBJECT TO MODIFICATIONS TO

PRESERVE ANY EXISTING VEGETATION AS DETERMINED BY THE ENGINEER.

3. WHEN REFERENCING IMPROVEMENTS ADJACENT TO THE SUBJECT PROPERTY THE

WORD "EXISTING" (OR ABBREVIATED "EX.") SHALL MEAN IMPROVEMENTS PROPOSED

BY THE DEVELOPER WHICH ARE INTENDED TO BE CONSTRUCTED PRIOR TO OR

CONCURRENT WITH THIS PROJECT.

4. NO TREES OR SHRUBS SHALL BE PLACED SO AS TO BLOCK ACCESS OR LINE OF

SIGHT TO FIRE HYDRANTS PLACED WITHIN LANDSCAPE ISLANDS THROUGHOUT THE

PROJECT SITE.

5. CONTRACTOR TO PROVIDE UTILITY RECORD DRAWINGS TO OWNER AND ENGINEER

PRIOR TO FINAL PAYMENT REQUEST.

6. ALL UNDERGROUND UTILITIES LOCATED BENEATH THE STABILIZED PORTION OF THE

ROAD BED SHALL BE INSTALLED PRIOR TO COMPACTION OF THE SUBGRADE.

7. CONTRACTOR SHALL NOTIFY ALL UTILITY PROVIDERS AT LEAST 48 HOURS PRIOR TO

THE START OF UNDERGROUND CONSTRUCTION THE CONTRACTOR SHALL

DETERMINE IF UTILITIES OTHER THAN THOSE SHOWN THE PLANS EXIST.

8. CONTRACTOR TO EXERCISE CARE TO PROTECT THE ROOTS OF TREES TO REMAIN.

WITH THE BRANCH SPREAD OF SUCH TREES, PERFORM ALL TRENCHING BY HAND.

OPEN THE TRENCH ONLY WHEN UTILITIES CAN BE INSTALLED IMMEDIATELY. PRUNE

INJURED ROOTS CLEANLY AND BACKFILL AS SOON AS POSSIBLE.

9. THE CONTRACTOR IS REQUIRED TO ADJUST ALL EXISTING AND PROPOSED VALVE

BOXES, MANHOLE RIMS, GRATES, ETC. AS REQUIRED TO MATCH THE PROPOSED

GRADES.

10. CASINGS AND/OR CONDUIT SHALL EXTEND FIVE(5) FEET BEYOND THE EDGE OF

PAVEMENT, BACK OF CURB AND/OR SIDEWALK AT EACH END AND SHALL BE

INCLUDED IN RECORD DRAWINGS TO THE ENGINEER.

11. CONTRACTOR TO INSTALL WATER MAINS SUCH THAT 18" OF MINIMUM CLEARANCE IS

PROVIDED FROM EXISTING FORCE MAINS. THE DISTANCE SHALL BE MEASURED

FROM OUTSIDE OF PIPE TO OUTSIDE OF PIPE.

1. ALL WASTEWATER CONSTRUCTION TO BE IN ACCORDANCE WITH THE CITY OF FORT

MYERS TECHNICAL SPECIFICATIONS AND DETAILS, LATEST EDITION

2. CONTRACTOR TO VERIFY INVERT ELEVATION AND LOCATION OF EXISTING SANITARY

SEWER MANHOLES PRIOR TO COMMENCEMENT OF CONSTRUCTION.

3. ALL GRAVITY SEWER LINES SHALL BE PVC (SDR 26), GREEN IN COLOR, UNLESS

OTHERWISE NOTED, WITH A MINIMUM OF 36" COVER.

4. ALL SEWER LENGTHS ARE APPROXIMATE AND ARE MEASURED FROM CENTER OF

STRUCTURE TO CENTER OF STRUCTURE.

5. MANHOLE TOPS ARE APPROXIMATE AND SHOULD BE ADJUSTED TO FINAL GRADE OR

PAVEMENT ELEVATION.

6. ALL SANITARY SEWER SERVICES TO BE 6" IN DIAMETER, UNLESS OTHERWISE NOTED.

7. ALL SANITARY SEWER MAIN TESTING SHALL BE IN ACCORDANCE WITH THE CITY OF

FORT MYERS TECHNICAL SPECIFICATIONS FOR GRAVITY SEWER.

8. CONTRACTOR TO COORDINATE WITH THE CITY OF FORT MYERS TO VERIFY THE

CONDITION OF THE COATING OF THE EXISTING MANHOLES AND RE-COAT IF

NECESSARY.

GENERAL UTILITY NOTES: GENERAL SANITARY SEWER NOTES:

1. ALL POTABLE WATER CONSTRUCTION TO BE IN ACCORDANCE WITH THE CITY OF

FORT MYERS UTILITIES TECHNICAL SPECIFICATIONS AND DETAILS, LATEST EDITION.

2. THE CONTRACTOR SHALL PLACE PROPOSED VALVES AS SHOWN. THE VALVE BOX

SHALL NOT BE LOCATED IN PAVEMENT, BRICK PAVERS OR DRIVEWAY AREAS WHERE

POSSIBLE.

3. ALL COMPONENTS OF THE POTABLE WATER SYSTEM, EXCLUDING FIRE HYDRANTS,

SHALL BE IN CONFORMANCE WITH THE AMERICAN NATIONAL STANDARDS

INSTITUTE/NSF INTERNATIONAL STANDARD 61. THE LOCATION OF PUBLIC WATER

SYSTEM MAINS SHALL BE IN ACCORDANCE WITH F.A.C. RULES 62-40, 62-550 AND

62-560. ALL COMPONENTS, INSTALLATION AND TESTING OF THE POTABLE WATER

SYSTEM SHALL BE IN ACCORDANCE WITH A.W.W.A. APPLICABLE STANDARDS.

4. PROPOSED WATERLINE FITTINGS ARE SHOWN AT MAJOR BENDS IN WATER MAIN

ALIGNMENT. CONTRACTOR SHALL UTILIZE ADDITIONAL FITTINGS AS NECESSARY TO

DEFLECT WATERLINE IN ACCORDANCE WITH THE UTILITY PROVIDER SPECIFICATIONS.

5. THE ENDS OF ALL CAPPED POTABLE WATERLINES SHALL BE MARKED WITH

ELECTRONIC MARKER AND 2'x4' STAKES 5' IN LENGTH WITH 2' ABOVE GROUND.

6. THE CONTRACTOR SHALL PROVIDE AND INSTALL BLUE-BLUE REFLECTIVE PAVEMENT

MARKERS AS REQUIRED IN CENTER OF ADJACENT TRAVEL LANE AT EACH FIRE

HYDRANT.

7. ALL WATER VALVES SHALL CONFORM TO A.W.W.A. C-509 RESILIENT SEATED TYPE.

8. CONTRACTOR SHALL USE 45° BENDS AT CONFLICTS. RESTRAINTS TO BE MEGA-LUG.

TYLER MJR GLANDS OR APPROVED EQUAL. CONTRACTOR SHALL NOT EXCEED 75%

OF THE MANUFACTURES RECOMMENDED MAXIMUM PIPE DEFLECTION.

9. ALL WATER MAINS SHALL HAVE A MINIMUM OF 30" COVER.

10. ALL POTABLE WATERLINES SHALL BE AWWA C-900, DR 18 CLASS 150 PVC RUBBER

GASKETED PIPE WITH BELL AND SPIGOT ENDS UNLESS OTHERWISE NOTED. ALL

WATERLINES UNDER PROPOSED ROADWAY SHALL BE DUCTILE IRON PIPE, CLASS 51.

11. METERS PROVIDED BY THE CITY OF FORT MYERS. CONTRACTOR TO INSTALL METERS.

GENERAL POTABLE WATER NOTES:

NORTH (RECORDS STORAGE)

FIRE FLOW AREA: 6,884 SF

CONSTRUCTION - TYPE II

FROM NFPA1 TABLE 18.4.5.2.1, THE REQUIRED FIRE FLOW WITH SPRINKLERS IS 1,000 GPM

SOUTH (PARKS AND RECREATION FACILITY)

FIRE FLOW AREA: 10,075 SF

CONSTRUCTION - TYPE II

FROM NFPA1 TABLE 18.4.5.2.1, THE REQUIRED FIRE FLOW WITH SPRINKLERS IS 1,000 GPM

THE FIRE FLOW PROVIDED BASED ON A FIRE FLOW TEST PERFORMED BY THE CITY OF

FORT MYERS ON APRIL 17, 2024 IS 4,998 GPM @ 20 P.S.I.

FIRE FLOW REQUIREMENTS:

ESTIMATED GENERATION RATE = 3.12 CY PER 1,000 S.F. PER MONTH

7,006 S.F. OF OFFICE SPACE

TOTAL MONTHLY VOLUME = 21.86 CY PER MONTH * 1.75 (RECYCLING) = 38.25 CY PER MONTH

58.61 CY PER MONTH / 4.3 WEEKS PER MONTH = 8.90 CY PERWEEK

SOLID WASTE TO BE COLLECTED BY CURB-SIDE PICK-UP

SOLID WASTE DISPOSAL REGULATIONS:

ALTERNATE PERVIOUS

PAVEMENT LOCATION

(±1,705 S.F.)

PAVING AND DRAINAGE

DETAILS

C7-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 7-

PA

V-

D R

G -D

ET

AI

LS

.D

W G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

NTS

1. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS

UNLESS OTHERWISE NOTED.

2. CURB SHALL BE CONSTRUCTED IN ACCORDANCE WITH FDOT INDEX 520-001.

3. CURB SHALL HAVE EXPANSION JOINTS INSTALLED AT ALL INLETS AND EVERY 500'±.

NOTES:

CURB DETAIL

TYPE 'D' CURB

6"

8"

R2"

1. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL

BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 1:50 (2%)

IN ALL DIRECTIONS PER ADA STANDARDS FOR ACCESSIBLE

DESIGN SECTION 4.6.

NOTES:

5'9' 12'

NTS

2' (TYP.)

2% MAX.

TYPICAL PARKING SPACE DETAIL

6" WHITE STRIPE

3 - 6" WHITE

CHEVRONS

EQUALLY SPACED

PER AISLE

6" BLUE

STRIPE

6" WHITE

STRIPE

PRECAST CONCRETE

WHEEL STOP

(TYP., SEE DETAIL)

HANDICAPPED PARKING SIGN

(REFERENCE F.D.O.T. INDEX

#17355) WITH ADDITIONAL

SIGN STATING "$250 FINE"

TYPICAL PARKING/ DRIVEWAY

PAVEMENT SECTION

NTS

1. 6" LIMEROCK BASE, PRIMED AND COMPACTED TO 98%

OF MAX. DENSITY (DETERMINED BY AASHTO T-180),

(MIN. LBR 100).

2. 6" STABILIZED SUBGRADE (MIN. LBR 40).

3. STABILIZED SUBGRADE TO EXTEND 1 FOOT BEYOND

EDGE OF PAVEMENT AND BACK OF CURB.

4. WHEN NO CURB IS PROPOSED LIMEROCK TO EXTEND

6 INCHES BEYOND EDGE OF PAVEMENT.

PAVEMENT NOTES:

6" STABILIZED SUBGRADE

6" LIMEROCK BASE

1.5" TYPE SP-9.5 ASPHALT CONCRETE

INSTALLED IN ONE LIFT

PRIME COAT

3,000 PSI

CONCRETE (MIN.)

FRONT EDGE OF

PARKING SPACE

WHEEL STOP DETAIL

NTS

(2) #3 BARS MIN.

24" #5 BARS INTO PAVEMENT (TYP.)

6"

6'

2' FOR STANDARD 18' DEEP

PARKING SPACES. WHEEL

STOP TO BE SET AT EDGE OF

PAVEMENT FOR 16' DEEP

PARKING SPACES

NTS

NOTES:

SI

D

EW

AL

K

SI

D

EW

AL

K

W/ STOP BAR

2' STOP

BAR

4'

SI

D

EW

AL

K

HIGH VISIBILITY

WIDTH VARIES

2'

1'

6' 1'

SI

D

EW

AL

K2' VALLEY

GUTTER

' R

O

AD

W

AY

(T

YP

TYPICAL PEDESTRIAN CROSSWALKS

STANDARD

1. SEE PLANS FOR TYPE OF CROSSWALK STRIPING AND

LOCATION.

2. DETAILS REFERENCED F.D.O.T. INDEX NO. 17346 & M.U.T.C.D.

SECTION 3B.17

3. CROSSWALKS SHALL HAVE A MAXIMUM RUNNING SLOPE OF

1:20 (5%) AND A MAXIMUM CROSS SLOPE OF 1:50 (2%) PER

ADA STANDARDS FOR ACCESSIBLE DESIGN SECTION 4.3.

DRAINAGE STRUCTURE

TYPE 'C' INLET

REFERENCE DETAIL

FDOT INDEX 425-052

FDOT INDEX 425-001, 425-010JUNCTION BOX

1. STRUCTURAL DESIGN AND REINFORCING SHALL CONFORM TO FDOT DESIGN

STANDARDS.

2. ALL CONCRETE SHALL HAVE COMPRESSION STRENGTH OF 3,000 PSI @ 28 DAYS.

STRUCTURE DESIGN INFORMATION:

DRAINAGE STRUCTURE TABLE

TYPE 'D' INLET FDOT INDEX 425-052

TYPE 'H' INLET FDOT INDEX 425-052

FDOT INDEX 430-021MITERED END

NTS

CONCRETE FLUME

SECTION

8" 8"2'

4"

PLAN

8" 2' 8"

R2' R2'

EDGE OF PAVEMENT

3' 12" DEEP RUBBLE RIP-RAP

ON MIRAFI FILTER FABRIC

(4" DIA. AVG.)

6"

4'

3' T

R

AN

SI

TI

O N

FL

U

M E

C U

R B

TO

F

LA

T

22.34"

36"

2X Ø .25" X 12.78"

ANCHOR RODS

Ø1.66"

1. INSTALLATION TO BE COMPLETED IN ACCORDANCE

WITH MANUFACTURER'S SPECIFICATIONS.

NOTE:

BIKE RACK DETAIL

NTS

SARIS CYCLING GROUP

6802 - 5 BIKE BG WAVE RACK

NTS

1. SIDEWALK SHALL BE CONSTRUCTED IN CONFORMANCE WITH FDOT STANDARD INDEX

522-001 AND STANDARD SPECIFICATION 522 AND CORRESPONDING STANDARDS.

2. COMPACT FILL AREAS TO MINIMUM 95% OF AASHTO T99 DENSITY.

3. SIDEWALK SHALL HAVE CONTRACTION JOINTS SPACED EQUALLY TO THE SIDEWALK

WIDTH AND HAVE EXPANSION JOINTS EVERY 20' MAXIMUM.

4. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS.

5. SIDEWALKS SHALL HAVE A MAXIMUM RUNNING SLOPE OF 1:22 (4.5%) AND A MAXIMUM

CROSS SLOPE OF 1:66 (1.5%) PER ADA STANDARDS FOR ACCESSIBLE DESIGN SECTION

4.3.

6. CURB RAMPS SHALL BE CONSTRUCTED IN CONFORMANCE WITH ADA STANDARDS FOR

ACCESSIBLE DESIGN SECTION 4.7 AND FDOT STANDARD INDEX 522-002.

NOTES:

WIDTH PER PLAN

4" THK.1.5% MAX

ON-SITE CONCRETE SIDEWALK DETAIL

4" TOOLED EDGE (TYP.)

BROOM FINISH

ALTERNATE PERVIOUS

PAVEMENT SECTION

NTS

1. 4" MIN. 1 12" COARSE AGGREGATE #57 STONE, COMPACTED TO 95% OF

MAX. DENSITY (DETERMINED BY AASHTO T-180).

2. 8" STABILIZED SUBGRADE (MIN. LBR 40).

3. STABILIZED SUBGRADE TO EXTEND 1 FOOT BEYOND EDGE OF PAVEMENT

AND BACK OF CURB.

4. WHEN NO CURB IS PROPOSED AGGREGATE TO EXTEND 6 INCHES

BEYOND EDGE OF PAVEMENT.

PAVEMENT NOTES:

8" STABILIZED SUBGRADE

4" COARSE AGGREGATE

#57 STONE

1.5" POROUS PAVEMENT (KBI

PERMADRIVE) INSTALLED IN

ONE LIFT

FILTER FABRIC

ALTERNATE PERVIOUS

PAVEMENT LOCATIONS

NTS

STABILIZED GRASS ACCESS

SECTION

NTS

12" STABILIZED

SUBGRADE

1. 12" STABILIZED SUBGRADE (MIN. LBR 40).

NOTES:

BAHIA SOD

NTS

1. SIDEWALK SHALL BE CONSTRUCTED IN CONFORMANCE WITH FDOT STANDARD INDEX

522-001 AND STANDARD SPECIFICATION 522 AND CORRESPONDING STANDARDS.

2. COMPACT FILL AREAS TO MINIMUM 95% OF AASHTO T99 DENSITY.

3. SIDEWALK SHALL HAVE CONTRACTION JOINTS SPACED EQUALLY TO THE SIDEWALK

WIDTH AND HAVE EXPANSION JOINTS EVERY 20' MAXIMUM.

4. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS.

5. SIDEWALKS SHALL HAVE A MAXIMUM RUNNING SLOPE OF 1:22 (4.5%) AND A MAXIMUM

CROSS SLOPE OF 1:66 (1.5%) PER ADA STANDARDS FOR ACCESSIBLE DESIGN SECTION

4.3.

6. CURB RAMPS SHALL BE CONSTRUCTED IN CONFORMANCE WITH ADA STANDARDS FOR

ACCESSIBLE DESIGN SECTION 4.7 AND FDOT STANDARD INDEX 522-002.

NOTES:

WIDTH PER PLAN

6" THK.1.5% MAX

OFF-SITE CONCRETE SIDEWALK DETAIL

4" TOOLED EDGE (TYP.)

BROOM FINISH

UTILITY DETAILS

C8-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 8-

C

FM

-D

ET

AI

LS

.D W

G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

R

City of Palms

TRFO

EYM

YT

S

CI OF

IRLF O AD

STANDARD DETAILS & SPECIFICATIONS

CATCH BASIN SUMP DETAIL

G - 99

N.T.S.

REV. DATE

5/2023

CITY OF FORT MYERS

PUBLIC UTILITIES DEPARTMENT

ENGINEERING DIVISION

2200 SECOND STREET, FORT MYERS, FLORIDA 33901

239-321-7445

ILLUSTRATION:

PLAN

SIDE VIEW

3"

12" (TYP.)

STONE OR ROCK

WRAPPED W/

FILTER FABRIC

(TYP.)

3" SUMP DRAIN

(TYP.)

1. STRUCTURES SHALL MEET

SPECIFICATIONS AS DETAILED

IN FDOT DESIGN STANDARDS,

LATEST EDITION.

2. ALTERNATE DESIGNS WILL BE

CONSIDERED. ALTERNATE

DESIGN SHALL BE DETAILED

ON PLANS AND CLEARLY

LABELED AS "MODIFIED".

3. SUMP SHALL HAVE A MINIMUM

OF TWO SUMP DRAINS ON

OPPOSITE FACES OF THE

STRUCTURE. HOLES CAN BE

ADJUSTED TO AVOID

CONFLICTS WITH W/

PRE-CAST PIPE OPENINGS.

4. SUMP TO BE PROVIDED ON

ALL STRUCTURES WHICH

WILL BE OWNED &

MAINTAINED BY THE CITY OF

FORT MYERS LOCATED IN

AREAS SUSCEPTIBLE TO

SEDIMENTATION.

NOTES:

3" DIA.

SUMP DRAIN 6"

12"

" M

IN

FILTER FABRIC (TYP.)

PROPERTY BOUNDARY

PROPERTY BOUNDARY

PARKS AND RECREATION FACILITYRECORDS STORAGE

PALM AVENUE

M

IC

H

IG

A N

A

VE

N U

E

SINGLE ROW STAKED

SILT FENCE (TYP.)

TEMPORARY CONSTRUCTION

ENTRANCE

SINGLE ROW STAKED

SILT FENCE (TYP.)

EROSION CONTROL

PLAN

C9-N

PL

A

N R

EV

IS

IO

N

S D

A

TE

D

ES

C R

IP

TI

O N

Sheet Number:

Project Manager: ADF

S

EC

O N

D S

TR

EE

T

FO

R T

M

YE

R S, F L

C

IT

Y O

F

FO

R T

M Y

ER

S

P A

R K

S

R

EC

R

EA

T

IO

N A

N D

C

LE

R K

O F

C O

U R

T R

EC

O

R D

S

FA

C

IL

IT

Y

O W

N

ER

D

EV

EL

O

PE

R

7/

/2

8:

A

M N

:\P R

O

JE

C

TS

\W

.2

-C

IT

Y O

F

FO

R T

M

YE

R S

PA

R

KS

R

EC

R

EA

TI

O

N F

AC

IL

IT

Y\

C

AD

\C O

N

ST

P

LA

N S\

N O

R

TH

P

AR

C

EL

P

LA

N S

ET

\P

LA

N

S

ET

\W

-2

-0 9-

ER

O

SI

O

N .D

W G

RESPEC

1412 Jackson Street, Suite #1

Fort Myers, FL 33901

(239) 418-0691

Drawn By:

Project Number:

County, State:

JBC

W0406-24002

LEE COUNTY, FL

Status:

PR

O

JE

C

T:

Florida Registry License No. 33253

AREA RESERVED FOR AGENCY USE

EN

G

IN

EE

R O

F R

EC

O

R D

A N

D R

EW

D

. F

IT

Z G

ER

A

LD

ST

A T

E O

F

FL

O R

ID

A

P R

O

FE

SS

IO

N A

L

EN

G

IN

EE

R

LI

C

EN

SE

N O

. 5

TH

IS

IT

EM

H

AS

B

EE

N

D

IG

IT

AL

LY

S

IG

N

ED

A

N D

SE

AL

ED

B

Y

AN

D R

EW

D

. F

IT

ZG

ER

AL

D

O N

T H

E D

AT

E

AD

JA

C

EN

T

TO

T H

E

SE

AL

PR

IN

TE

D

C O

PI

ES

O F

TH

IS

D O

C U

M

EN

T

AR

E N

O T

C O

N

SI

D

ER

ED

S

IG

N

ED

A

N D

S

EA

LE

D

A N

D

TH

E

SI

G N

AT

U

R E

M U

ST

B

E

VE

R

IF

IE

D

O N

A N

Y

EL

EC

TR

O N

IC

C

O

PI

ES

LEGEND

STAKED SEDIMENT LOG @ INLETS OR

MIRAFI FABRIC

STAKED SILT FENCE

RUNOFF

STEEL OR

WOOD POST

EXTRA STRENGTH FILTER

FABRIC NEEDED WITHOUT

WIRE MESH SUPPORT

10 FT. MAX SPACING WITH WIRE SUPPORT FENCE

6 FT. MAX SPACING WITHOUT WIRE SUPPORT FENCE

FLOW

FLOW

FLOW

12" MIN.

RUNOFF

STEEL OR

WOOD POST

36" HIGH MAX.

PONDING HEIGHT PONDING HEIGHT

FILTER FABRIC ATTACHED

SECURELY TO UPSTREAM

SIDE OF POST

4"x6" TRENCH WITH

COMPACTED BACKFILL GRAVEL

8"

12" MIN.

9" MAX.

(RECOMMENDED

STORAGE HT.)

STANDARD DETAIL

TRENCH WITH NATIVE BACKFILL

ALTERNATE DETAIL

TRENCH WITH GRAVEL

1. INSPECT AND REPAIR FENCE AFTER EACH STORM

EVENT AND REMOVE SEDIMENT WHEN

NECESSARY.

2. REMOVED SEDIMENT SHALL BE DEPOSITED TO AN

AREA THAT WILL NOT CONTRIBUTE SEDIMENT

OFF-SITE AND CAN BE PERMANENTLY STABILIZED.

3. SILT FENCE SHALL BE PLACED ON SLOPE

CONTOURS TO MAXIMIZE PONDING EFFICIENCY.

NOTES:

NTS

SILT FENCE DETAIL

1. THESE DETAILS REPRESENT TYPICAL BEST MANAGEMENT PRACTICES FOR SOIL EROSION CONTROL.

2. PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITY APPROPRIATE EROSION CONTROL DEVICES SHALL BE

INSTALLED TO CONTROL AND REDUCE SOIL EROSION AND SEDIMENT TRANSPORT TO OFF SITE AREAS. THE CONTRACTOR SHALL MAINTAIN THESE DEVICES THROUGHOUT THE DURATION OF CONSTRUCTION. ALL DEVICES

SHALL REMAIN IN PLACE UNTIL PERMANENT EROSION CONTROL IS ESTABLISHED.

3. AREAS LOCATED ADJACENT TO UNDEVELOPED AREAS SHALL BE STABILIZED WITH SOD IMMEDIATELY UPON

REACHING FINAL GRADE.

4. THE CONTRACTOR SHALL SUPPLEMENT THIS PLAN AS MAY BE REQUIRED TO CONTROL AND REDUCE SOIL EROSION BASED ON THE CONTRACTORS MEANS, METHODS AND TECHNIQUE OF CONSTRUCTION. THE CONTRACTOR SHALL ALSO FILE A NPDES NOTICE OF INTENT WITH THE EPA AND THE CITY OF FORT MYERS AT LEAST 48 HOURS PRIOR TO

THE START OF CONSTRUCTION.

5. DURING CONSTRUCTION, ALL INLET OPENINGS SHALL BE COVERED WITH FILTER FABRIC (MIRAFI 140N, OR APPROVED EQUAL) TO PREVENT DEBRIS FROM FALLING INTO THE INLET. FILTER FABRIC TO BE REMOVED FROM ALL

INLETS IMMEDIATELY UPON PROPER STABILIZATION OF CONSTRUCTED IMPROVEMENTS.

6. THE CONSTRUCTION OF THIS PROJECT WILL BE IN COMPLIANCE WITH SEE TURTLE AND SMALLTOOTH SAWFISH

CONSTRUCTION CONDITIONS AND THE STANDARD MANATEE CONDITIONS FOR IN WATER WORK.

7. CONSTRUCTION DEBRIS FROM THE PROJECT WILL BE REMOVED FROM THE SITE BY TRUCK.

8. TURBIDITY SCREENS WILL BE UTILIZED AND REMAIN IN PLACE THROUGHOUT CONSTRUCTION.

9. SILT FENCE WILL BE UTILIZED AND REMAIN IN PLACE THROUGHOUT CONSTRUCTION.

10. TURBIDITY SCREENS AND SILT FENCE WILL BE INSPECTED DAILY.

11. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING RUTS FROM EQUIPMENT DURING INSTALLATION AND

MAINTENANCE OF THE PROPOSED SILT FENCE

EROSION CONTROL NOTES:

MIRAFI FILTER FABRIC

#57 STONE

FINISHED GRADE

NTS

TEMPORARY CONSTRUCTION

ENTRANCE SECTION

N

E W

300 15 60

W0406-24002-01-COVER-COVER
W0406-24002-02-AERIAL-PLAN-SHEET
W0406-24002-03-DEMO-PLAN-SHEET
W0406-24002-04-SITE-PLAN-SHEET
W0406-24002-05-PAV-DRG-PLAN-SHEET
W0406-24002-06-UTILITY-PLAN-SHEET
W0406-24002-07-PAV-DRG-DETAILS-PLAN-SHEET
W0406-24002-08-CFM-DETAILS-PLAN-SHEET
W0406-24002-09-EROSION-PLAN-SHEET
2025-07-11T09:19:19-0400
Andrew D Fitzgerald

File details come from the government source that posted it. Updated .