This Addendum No. 1, issued on April 26, 2018, by the State of Michigan Department of Technology, Management and Budget, State Facilities Administration Design and Construction Division, provides design and construction specifications for fencing and gate work related to Bid Pack #3A. The addendum contains detailed architectural drawings and specifications for chain-link fence installation, modification, and enhancement work across multiple locations. Key specifications include the installation of hot-dipped galvanized steel fabric with 2-inch diamond mesh, knuckled top and bottom configurations, and detainer hook razor ribbon with 12-inch loop spacing. The work involves grading and upgrading existing interior and exterior fencing, adding razor ribbon barriers, installing new steel columns and transom sections above gates, and extending existing gate and fence fabrics to cover gaps. All fencing frames must be constructed in shops with field-measured posts, and all welds must be clean, uniform, and continuous, with grinding and galvanizing finishing. The contractor is required to provide shop drawings for all fencing work prior to construction.
The document references three distinct contract order numbers—60230, 62240, and 37180—with corresponding consultant job numbers, indicating this work may encompass multiple separate project scopes or phases within the broader facility modification initiative. The drawings specify grading work at multiple fence locations, including interior fence areas, exterior fence perimeters, gator grade sections, sally port fences and gates, and stun fence areas. Specific detail requirements are provided for razor ribbon installation heights, spacing, concrete footing specifications, and gate operation systems designed to function as integrated units. No pricing information, budget allocations, or contract award details are included in this addendum document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-000
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
60230 consultant job no.
17302.00 sheet title
472/17396.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
ADDENDUM #1 04/26/20181
C-100
JFS
N file no.
checked by drawn by consultant issue date index no.
contract order no.
60230 consultant job no.
17302.00 sheet title
472/17396.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
ADDENDUM #1 04/26/20181
1 1
FENCING AND GATES NOTES
1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED
STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"
DIAMOND MESH.
2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.
3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.
4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.
5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE
POSTS PRIOR TO CONSTRUCTION.
6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).
7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND
WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.
GRADE
EXISTING INTERIOR
"A" FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
16'-3" x x x x x x x x x x x x x
16'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
16'-0" x x x x x x x x x x x x x
APPROACH
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
16x x x x x x x x x x x x x
GATOR
GRADE
EXISTING INTERIOR
"A" FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
16'-3" x x x x x x x x x x x x x 16'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
16'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING 36
APPROACH
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
7'-10"
GATOR
EXISTING 16"
SPOOLS, TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
ADD INSTABARRIER
RAZOR RIBBON w/ 12"
LOOP SPACING
REMOVE EXISTING
16" SPOOL, TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
16x x x x x x x x x x x x x
GRADE
EXISTING INTERIOR
FENCE
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
x x x x x x x x x x x x x
NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
x x x x x x x x x x
EXISTING BUILDING
x x x x x x x x x x x x x
EXISTING SPOOL
x x x x x x x x x x x x x x x NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING 30" SPOOLS,
TYP
NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
GRADE
EXISTING SALLY
PORT FENCE
x x x x x x x x x x x x x
EXISTING 30" SPOOL
NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
GRADE
EXISTING SALLY
PORT GATE
x x x x x x x x x x x x x x x x x x x x x x x x x x 31 x x x x x x x x x x x x x x x x x x x x x x x x x x
REMOVE EXISTING 16"
SPOOL
C-200
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
60230 consultant job no.
17302.00 sheet title
472/17396.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
ADDENDUM #1 04/26/20181
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
62240 consultant job no.
17299.00 sheet title
472/17406.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
file no.
checked by drawn by consultant issue date index no.
contract order no.
62240 consultant job no.
17299.00 sheet title
472/17406.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
ADDENDUM #1 04/26/2018
C-100
JKB
JFS
N file no.
checked by drawn by consultant issue date index no.
contract order no.
62240 consultant job no.
17299.00 sheet title
472/17406.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
ADDENDUM #1 04/26/2018
C-101
JKB
JFS
N
FENCING AND GATES NOTES
1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED
STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"
DIAMOND MESH.
2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.
3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.
4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.
5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE
POSTS PRIOR TO CONSTRUCTION.
6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).
7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND
WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.
GRADE
EXISTING INTERIOR
STUN FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
16'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
ADD INSTABARRIER
RAZOR RIBBON w/ 12"
LOOP SPACING
APPROACH
REMOVE BRACKET
TO MOUNT
CAMERAS. SEE C100
FOR LOCATIONS
CUT OFF AND CAP
EXISTING POST
GRADE
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING 36
GRADE
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING 36
x x x x x x x x x x x x xADD DETAINER HOOK RAZOR RIBBON w/ 12"
LOOP SPACING
GRADE
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
x x x x x x x x x x x x x
10'-6"
SCALE: N.T.S.
7'-2"
GATOR
NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
x x x x x x x x x x x x x
EXISTING BUILDING
x x x x x x x x x x x x x
EXISTING SPOOLS
x x x x x x x x x x x x x
NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
EXISTING STUN
FENCE
18" X 16" DEEP
CONCRETE FOOTING
FINISH GRADE
10'-6"
TOP, BOTTOM, AND MIDDLE CLAMP
ATTACHED TO NEW STEEL
COLUMN AND THE TOP, BOTTOM,
AND MIDDLE RAILS OF THE
EXISTING FENCE SYSTEM (HAVE
TO RUN THROUGH THE EXISTING
FENCE)
INSTALL NEW 4" DIA
STEEL COLUMN
EXISTING FENCE
FINISHED GRADE
13'-6"
EXISTING FENCE
EXISTING GATE
ADDED RAZOR
RIBBON PER DETAIL
#7 ON C200
ADD TRANSOM
ABOVE GATE
ADD (3) ROWS 31"
DETAINER HOOK
RAZOR RIBBON.
ADD (3) 30"
DETAINER HOOK
RAZOR RIBBON WITH
12" LOOP SPACING
ADD (3) 30" DETAINER
HOOK RAZOR RIBBON
WITH 12" LOOP SPACING
30"30"
30"
10' -6"
EXTEND EXISTING
GATE AND FENCE
FABRIC TO COVER
THE GAP
ADD FENCE LATCH FORK TO MAKE
GATES OPERATE TOGETHER AS A
SYSTEM
GRADE
EXISTING SPOOL
x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
x x x x x x x x x x x x x
FINISHED GRADE
14'-0"
EXISTING FENCE
EXISTING GATE
ADDED RAZOR
RIBBON PER DETAIL
#8 ON C200
ADD TRANSOM
ABOVE GATE
ADD (3) ROWS 31"
DETAINER HOOK
RAZOR RIBBON.
ADD (3) 30"
DETAINER HOOK
RAZOR RIBBON WITH
12" LOOP SPACING
ADD (3) 30" DETAINER
HOOK RAZOR RIBBON
WITH 12" LOOP SPACING
30"30"
30"
10' -6"
EXTEND EXISTING
GATE AND FENCE
FABRIC TO COVER
THE GAP
C-200
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
62240 consultant job no.
17299.00 sheet title
472/17406.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
ADDENDUM #1 04/26/20181
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
37180 consultant job no.
17297.00 sheet title
472/17405.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
File details come from the government source that posted it. Updated .