20180413_ICF_BidPack 3A.pdf

PDF 2 MB Posted

Attached to
472/17396. SMD St Louis CF - Razor Ribbon Bid Pack 3A
Solicitation number
RFQ 171 180000000556 2
Issued by
Macomb County, Michigan

About this file

This is a design and construction bid pack prepared by the State of Michigan Department of Technology, Management and Budget, State Facilities Administration Design and Construction Division, issued on April 13, 2018, for a fencing and gates project identified as Contract Order No. 40630 and Consultant Job No. 17295.00. The project involves the installation and modification of chain link fencing and gates at an existing facility, including the addition of razor ribbon detainers with 12-inch loop spacing to both new and existing fence sections. The scope encompasses grading work, installation of new detainer hook razor ribbon fencing, and replacement of existing razor ribbon with new specifications at multiple locations around an existing building and detention area. The bid pack is designated as a 50 percent review set dated March 19, 2018, with the formal bid package issued on April 13, 2018.

All fencing materials, including fabric, rails, posts, gates, and fittings, must be hot-dipped galvanized steel with zinc coating, featuring two-inch diamond mesh construction with knuckled tops and bottoms. Contractors are required to submit shop drawings for all fencing work and must field-measure existing posts prior to frame construction. All gate frames shall be constructed with weld cupped joints in the shop, with all welds required to be clean, uniform, continuous, and free of rust, with grinding completed prior to galvanizing. The specifications indicate existing stun fence and spool configurations are to be retained or modified as indicated on the construction drawings, with precise dimensions provided for fence heights and razor ribbon placements throughout the project site.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-000

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

40630 consultant job no.

17295.00 sheet title

472/17397.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

50% REVIEW SET 03/19/2018

BID PACK #3A 04/13/2018

C-100

JKB

JFS

N file no.

checked by drawn by consultant issue date index no.

contract order no.

40630 consultant job no.

17295.00 sheet title

472/17397.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

FENCING AND GATES NOTES

1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED

STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"

DIAMOND MESH.

2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.

3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.

4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.

5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE

POSTS PRIOR TO CONSTRUCTION.

6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).

7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND

WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.

GRADE

EXISTING INTERIOR

"A" STUN FENCE

EXISTING EXTERIOR

"B" FENCE

ADD DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

18'-2" x x x x x x x x x x x x x

11'-6" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

11'-6" x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING

APPROACH

GATOR

8'-10" x x x x x x x x x x x x x x x x x x x x x x x x x x

NEW 31" DETAINER

HOOK RAZOR RIBBON

@ 12" OC

x x x x x x x x x x x x x

EXISTING BUILDING

x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS

GRADE

x x x x x x x x x x x x x

REMOVE EXISTING

RAZOR RIBBON AND

INSTALL NEW

DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

x x x x x x x x x x x x x x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING STUN

FENCE

EXISTING SPOOL

C-200

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

40630 consultant job no.

17295.00 sheet title

472/17397.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

File details come from the government source that posted it. Updated .