This is a bid pack document from the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division, for fencing and gates work in Muskegon. The document, dated April 13, 2018, is a 50% review set containing detailed specifications and technical drawings for fencing installation. The work includes installation of chain-link fencing with hot-dipped galvanized steel components, 2-inch diamond mesh fabric, and various gate configurations. The scope specifies both interior and exterior fence grades, with add/deduct options for detainer hooks and razor ribbon additions with 12-inch loop spacing. Concrete footings are required at 18 inches in diameter and 6 inches deep with MDOT 23A crushed limestone base. All fence components must feature knuckled tops and bottoms, and the contractor is responsible for providing shop drawings and field-measuring posts prior to construction.
The specifications mandate that all welds be clean, uniform, continuous, and free of rust, with grinding required prior to galvanized finish application. All gate frames must be constructed with weld cupped joints using fish mouth configuration. The document includes technical drawings showing fence sections at varying heights (11 feet 6 inches and 14 feet) and detailed footing specifications. This bid pack represents the design phase documentation establishing the technical requirements and quality standards for the fencing contractor to follow during the construction phase. No pricing information, award dates, or contract term details are contained within this technical specification document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-000
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
38570 consultant job no.
17923.00 sheet title
472/17408.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
C-100
JKB
JFS
N file no.
checked by drawn by consultant issue date index no.
contract order no.
38570 consultant job no.
17923.00 sheet title
472/17408.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
FENCING AND GATES NOTES
1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED
STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"
DIAMOND MESH.
2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.
3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.
4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.
5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE
POSTS PRIOR TO CONSTRUCTION.
6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).
7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND
WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.
GRADE
EXISTING INTERIOR
"A" FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
± 14'-0" x x x x x x x x x x x x x
11'-6" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
11'-6" x x x x x x x x x x x x x
ADD DEDUCT DETAINER
HOOK RAZOR RIBBON
w/ 12" LOOP SPACING 36 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
ADD INSTABARRIER
RAZOR RIBBON w/ 12"
LOOP SPACING
APPROACH
x x x x x x x x x x x x x
1'-0"
4'-0"
SCALE: N.T.S.
6" OF SOIL
WIRE TIES TO CONNECT
5/6" STEEL ROD TO PIER,
TYP.
CONCRETE FOOTING
TYP., 18" DIA.
6" DEEP MDOT 23A
CRUSHED LIMESTONE
4'-4"
QUAD
(48" WIDE)
GRADE
EXISTING
INTERIOR
FENCE
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
11'-6" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING 36
C-200
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
38570 consultant job no.
17923.00 sheet title
472/17408.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
File details come from the government source that posted it. Updated .