472/17396. SMD St Louis CF - Razor Ribbon Bid Pack 3A
Solicitation number
RFQ 171 180000000556 2
Issued by
Macomb County, Michigan

About this file

This is a bid pack document from the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division, for fencing and gates work in Muskegon. The document, dated April 13, 2018, is a 50% review set containing detailed specifications and technical drawings for fencing installation. The work includes installation of chain-link fencing with hot-dipped galvanized steel components, 2-inch diamond mesh fabric, and various gate configurations. The scope specifies both interior and exterior fence grades, with add/deduct options for detainer hooks and razor ribbon additions with 12-inch loop spacing. Concrete footings are required at 18 inches in diameter and 6 inches deep with MDOT 23A crushed limestone base. All fence components must feature knuckled tops and bottoms, and the contractor is responsible for providing shop drawings and field-measuring posts prior to construction.

The specifications mandate that all welds be clean, uniform, continuous, and free of rust, with grinding required prior to galvanized finish application. All gate frames must be constructed with weld cupped joints using fish mouth configuration. The document includes technical drawings showing fence sections at varying heights (11 feet 6 inches and 14 feet) and detailed footing specifications. This bid pack represents the design phase documentation establishing the technical requirements and quality standards for the fencing contractor to follow during the construction phase. No pricing information, award dates, or contract term details are contained within this technical specification document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-000

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

38570 consultant job no.

17923.00 sheet title

472/17408.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

50% REVIEW SET 03/19/2018

BID PACK #3A 04/13/2018

C-100

JKB

JFS

N file no.

checked by drawn by consultant issue date index no.

contract order no.

38570 consultant job no.

17923.00 sheet title

472/17408.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

FENCING AND GATES NOTES

1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED

STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"

DIAMOND MESH.

2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.

3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.

4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.

5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE

POSTS PRIOR TO CONSTRUCTION.

6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).

7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND

WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.

GRADE

EXISTING INTERIOR

"A" FENCE

EXISTING EXTERIOR

"B" FENCE

EXISTING SPOOLS,

TYP

± 14'-0" x x x x x x x x x x x x x

11'-6" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x

11'-6" x x x x x x x x x x x x x

ADD DEDUCT DETAINER

HOOK RAZOR RIBBON

w/ 12" LOOP SPACING 36 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING

APPROACH

x x x x x x x x x x x x x

1'-0"

4'-0"

SCALE: N.T.S.

6" OF SOIL

WIRE TIES TO CONNECT

5/6" STEEL ROD TO PIER,

TYP.

CONCRETE FOOTING

TYP., 18" DIA.

6" DEEP MDOT 23A

CRUSHED LIMESTONE

4'-4"

QUAD

(48" WIDE)

GRADE

EXISTING

INTERIOR

FENCE

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x

11'-6" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING 36

C-200

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

38570 consultant job no.

17923.00 sheet title

472/17408.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

File details come from the government source that posted it. Updated .