20180413_StLouis_BidPack 3A.pdf
PDF 1 MB Posted
- Solicitation number
- RFQ 171 180000000556 2
- Issued by
- Macomb County, Michigan
About this file
This is a bid pack document from the State of Michigan Department of Technology, Management and Budget, State Facilities Administration Design and Construction Division, dated April 13, 2018, for fencing and gates work. The document contains design specifications and technical drawings for chain link fence installation and modification at an unspecified facility. The project involves two main grades of fencing work: Grade 1 addresses existing interior "A" fence and exterior "B" fence with spools measuring approximately 16 feet in length, while Grade 2 Gator addresses similar fencing with modifications including the removal of existing 16-inch spools and addition of detainer hook razor ribbon with 12-inch loop spacing and InstaBARRIER razor ribbon. The specifications indicate multiple fence sections with varying dimensions, including approach areas and grading work.
All fencing materials and components must be hot-dipped galvanized steel with zinc coating, featuring 2-inch diamond mesh fabric, knuckled tops and bottoms, and continuous clean welds free of rust. The contractor is required to provide shop drawings for all fencing work, perform field measurements of existing posts prior to construction, and construct all frames and gate frames in the shop using weld cupped joints with fish mouth connections. The document represents a 50 percent review set issued on March 19, 2018, with the bid pack finalized on April 13, 2018, under contract order number 60230 and consultant job number 17302.00. No pricing, bid due dates, site visit requirements, or award information is included in this excerpt of the bid pack.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-000
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
60230 consultant job no.
17302.00 sheet title
472/17396.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID PACK #3A 04/13/2018
C-100
JKB
JFS
N file no.
checked by drawn by consultant issue date index no.
contract order no.
60230 consultant job no.
17302.00 sheet title
472/17396.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
FENCING AND GATES NOTES
1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED
STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"
DIAMOND MESH.
2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.
3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.
4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.
5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE
POSTS PRIOR TO CONSTRUCTION.
6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).
7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND
WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.
GRADE
EXISTING INTERIOR
"A" FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
16'-3" x x x x x x x x x x x x x
16'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
16'-0" x x x x x x x x x x x x x
APPROACH
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
16x x x x x x x x x x x x x
GATOR
GRADE
EXISTING INTERIOR
"A" FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
16'-3" x x x x x x x x x x x x x 16'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
16'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING 36
APPROACH
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
7'-2"
GATOR
REMOVE EXISTING
16" SPOOLS, TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
ADD INSTABARRIER
RAZOR RIBBON w/ 12"
LOOP SPACING
x x x x x x x x x x x x x
C-200
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
60230 consultant job no.
17302.00 sheet title
472/17396.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
File details come from the government source that posted it. Updated .