This is a pricing worksheet template for the Divers Life Support System (DLSS) Maintenance Services solicitation issued by the Naval Supply Systems Command. The worksheet is designed for small business contractors to submit firm-fixed-price quotations for DLSS maintenance services supporting Explosive Ordnance Disposal Group One (EODGRU1) in San Diego, California. The solicitation is restricted to small business concerns and uses NAICS code 541380 (Testing Laboratories and Services), with a small business standard of $19.0 million. Responses must be submitted by 5:00 PM Hawaii Standard Time on Monday, August 24, 2026, with questions directed to Ms. Rachel Tamashiro at rachel.m.tamashiro.civ@us.navy.mil.

The pricing worksheet serves as the template through which contractors will provide their cost proposals for maintenance services, parts availability, and labor rates as specified in the attached Performance Work Statement and DLSS Service Parts List. This is a firm-fixed-price purchase order acquisition with no separate written solicitation being issued; the combined synopsis/solicitation announcement constitutes the sole solicitation document. Qualified small business sources must demonstrate capability to meet all maintenance service requirements outlined in the PWS and related attachments to be eligible for consideration.

View the file

Other files

File Type Posted
2.03 26Q4023_Amd1_Att8_QandA.pdf PDF
2.07 26Q4023_Att1_Comb SS.pdf PDF
2.07a 26Q4023_Att4_FAR_DFARS.pdf PDF
2.07a 26Q4023_Att6_QASP_Log.xlsx XLSX spreadsheet
2.07a 26Q4023_Att5_QASP.pdf PDF
2.07a 26Q4023_Att2_PWS.pdf PDF
2.07a 26Q4023_Att3_PWS_Att1_Service List.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUMMARY

COMBINED SYNOPSIS SOLICITATION N0060426Q4023
EODGRU1 Divers Life Support Systems (DLSS) Maintenance Services

This table pre-populates automatically using the values entered in the respective tabs. Base Year Option Year One (1) 6-Month Option to Extend Services

(IAW FAR 52.217-8)

Category A Subtotal$ - 0$ - 0$ - 0
Category B Subtotal$ - 0$ - 0$ - 0
Category C Subtotal$ - 0$ - 0$ - 0
Category D Subtotal$ - 0$ - 0$ - 0
Category E Subtotal$ - 0$ - 0$ - 0
Category F Subtotal$ - 0$ - 0$ - 0
Category G Subtotal$ - 0$ - 0$ - 0
Category H Subtotal$ - 0$ - 0$ - 0
Category I Subtotal$ - 0$ - 0$ - 0
Category J Subtotal$ - 0$ - 0$ - 0
Category K Subtotal$ - 0$ - 0$ - 0
Category L Subtotal$ - 0$ - 0$ - 0
TOTAL EVALUATED PRICE$ - 0$ - 0$ - 0
Input the following information:
Vendor Name:
CAGE Code:
Unique Entity Identifier:
Business Size:
Point of Contact (POC) Name:
POC Email:
POC Phone:
Additional Comments:

BASE YEAR

EODGRU1 DIVERS LIFE SUPPORT SYSTEMS (DLSS) MAINTENANCE REQUIREMENTS WITH PARTS LIST
CategoryPWS SectionLine Item No.Category Description# of AssetsDescriptionAssociated Item(s)/Part Number(s)Quantity per AssetTotal Quantity Serviced
(based on an annual basis unless specified otherwise)NotesUnit PriceUnit (i.e., Each, Group)Extended Price
A3.2.11Gas Cylinders50Refill HeO2 88/12% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees.50
A3.2.22Gas Cylinders30Refill O2 100% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees.30
A3.2.33Gas Cylinders20Refill O2N2 60/40% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees.20
CATEGORY A SUBTOTAL$ - 0

B 3.3.1 4 Oxygen Transfer Pump Assembly (OTPA) Maintenance 3 24M Calibrate oxygen outlet pressure gauge OHP-G201 3 9

B3.3.25Oxygen Transfer Pump Assembly (OTPA) Maintenance324M Replace Pump Assembly Air Cycling Valve O-rings and Bumper39
B3.3.2.16Oxygen Transfer Pump Assembly (OTPA) Maintenance324M Replace Pump Assembly Air Cycling Valve O-rings and BumperProvide air cycling valve kit (p/n 17329)39
B3.3.37Oxygen Transfer Pump Assembly (OTPA) Maintenance336M Test Oxygen Transfer Pump Assembly Relief Valves39
B3.3.48Oxygen Transfer Pump Assembly (OTPA) Maintenance336M Inspect Oxygen In-Line Filters26
B3.3.59Oxygen Transfer Pump Assembly (OTPA) Maintenance372M Deliver Oxygen Transfer Pump Assembly for Overhaul13
CATEGORY B SUBTOTAL$ - 0
C3.4.110Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge312Main service item. Same colored row(s) immediately below indicate required supporting parts.
C3.4.1.111Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide drying filter cartridge (p/n 058825A)28
C3.4.1.212Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide Securus filter cartridge (p/n 060037A)14
C3.4.1.313Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide O-ring (p/n N04735)312
C3.4.1.414Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide backup ring (p/n N04736)312
C3.4.1.515Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide air intake filter (p/n N25886)14

C 3.4.2 16 Bauer O26-D Compressor Maintenance 4 18M Calibrate Diver's Portable Gauges 4

C 3.4.3 17 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element 10 HRS 40 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

C 3.4.3.1 18 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element Provide sintered filter element (p/n 061860) 1 4

C3.4.419Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter Assembly28Main service item. Same colored row(s) immediately below indicate required supporting parts.
C3.4.4.120Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide oil filter (p/n N25326)14
C3.4.4.221Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide gasket (p/n 077774)14
C3.4.4.322Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide O-ring (p/n N04058)14
C3.4.4.423Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide O-ring (p/n N25327)14
C3.4.4.524Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide compressor oil (p/n OIL-0024)28
C3.4.525Bauer O26-D Compressor Maintenance424M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves28Main service item. Same colored row(s) immediately below indicate required supporting parts.
C3.4.5.126Bauer O26-D Compressor Maintenance424M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check ValvesProvide check valve (p/n VAL-0007)28
C3.4.5.227Bauer O26-D Compressor Maintenance424M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check ValvesProvide pressure maintaining valve (p/n VAL-0053)14
C3.4.628Bauer O26-D Compressor Maintenance436M Test Relief Valves Removed From System4
CATEGORY C SUBTOTAL$ - 0
D3.5.129Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier element15Main service item. Same colored row(s) immediately below indicate required supporting parts.
D3.5.1.130Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide air purifier element (p/n 058821A)15
D3.5.1.231Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide O-ring (p/n N04735)15
D3.5.1.332Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide backup ring (p/n N04736)15
D3.5.1.433Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementA-11 Change CO/Moisture indicator element15
D3.5.1.534Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide moisture indicator element (p/n ELM-0056)15
D3.5.235Bauer C-D/DV/Navy Compressor Maintenance518M Calibrate Diver's Portable Gauges210
D3.5.336Bauer C-D/DV/Navy Compressor Maintenance536M Test Relief Valves Removed From System210
CATEGORY D SUBTOTAL$ - 0
E3.6.137Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite2472Main service item. Same colored row(s) immediately below indicate required supporting parts.
E3.6.1.138Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsiteLabor involved in TRCS calibration (relief valve removal, system line-ups, joint testing)1854
E3.6.1.239Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsiteProvide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal)618
E3.6.1.340Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsiteProvide AS3581-010 O-rings, cleaned IAW MIL STD 1330D (for TRCS med-lock gauge)13

E 3.6.2 41 Transportable Recompression Chamber System (TRCS) 3 36M Perform Visual Inspection of Acrylic Window 5 15

E3.6.342Transportable Recompression Chamber System (TRCS)336M Test Relief Valves Removed from System onsite824Main service item. Same colored row(s) immediately below indicate required supporting parts.
E3.6.3.143Transportable Recompression Chamber System (TRCS)336M Test Relief Valves Removed from System onsiteLabor involved in TRCS calibration (relief valve removal, system line-ups, joint testing)6 HRS18 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.3.244Transportable Recompression Chamber System (TRCS)336M Test Relief Valves Removed from System onsiteProvide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal)618

E 3.6.4 45 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings 5 HRS 15 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

E3.6.4.146Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and HousingsProvide Swagelok filter element (p/n M-8F-K4-15)515
E3.6.4.247Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and HousingsProvide Swagelok filter gasket (p/n SS-8TF-K2)515
E3.6.4.348Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and HousingsClean filter elements and gaskets IAW MIL STD 1330E6 HRS18 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

E 3.6.5 49 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings 6 HRS 18 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

E3.6.5.150Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transfer Lock (TL) T-Filter Elements and HousingsProvide Swagelok filter element (p/n M-8F-K4-15)412
E3.6.5.251Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transfer Lock (TL) T-Filter Elements and HousingsProvide Swagelok filter gasket (p/n SS-8TF-K2)412
E3.6.5.352Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transfer Lock (TL) T-Filter Elements and HousingsClean filter elements and gaskets IAW MIL STD 1330E6 HRS18 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.653Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement1236Main service item. Same colored row(s) immediately below indicate required supporting parts.
E3.6.6.154Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementLabor to disassemble and reassemble (4) flask racks assemblies while maintaining cleanliness IAW MIL STD 1330E, including filling flasks for 24 hour joint tightness drop test12 HRS36 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.6.255Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide rupture discs (p/n 20Z), cleaned IAW MIL STD1330E1236
E3.6.6.356Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-916 o-rings, cleaned IAW MIL STD 1330E1236
E3.6.6.457Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-010 O-rings, cleaned IAW MIL STD 1330E1236
E3.6.6.558Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementDiver’s air gas required for flask rack joint tightness test (leave flasks full and provide current satisfactory air sample from diver’s air source)13
E3.6.759Transportable Recompression Chamber System (TRCS)360M Hydrostatically Test Fire Extinguisher13
E3.6.860Transportable Recompression Chamber System (TRCS)3U-2 Hydrostatically Test Hoses5 HRS15 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.961Transportable Recompression Chamber System (TRCS)3U-3 Clean and Inspect Interlock Poppet and NATO Flange Bearings8 HRS24 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.1062Transportable Recompression Chamber System (TRCS)3U-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffusers/Silencers3 HRS9 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.1163Transportable Recompression Chamber System (TRCS)3REC and OQE package4 HRS12 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
CATEGORY E SUBTOTAL$ - 0
F3.7.164SNDL Maintenance118M Test and Inspect ASRA Check Valve (AHP-V445)1
F3.7.265SNDL Maintenance124M Calibrate Diver's Life Support System (DLSS) Installed Gauges2222

F 3.7.3 66 SNDL Maintenance 1 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element 2 HRS 2 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

F3.7.3.167SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide filter element (p/n U-10007)22
F3.7.3.268SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementClean (2) filter elements IAW MIL STD 1622B22 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.3.369SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B22
F3.7.3.470SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B22
F3.7.3.571SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide M83248/2-015 O-rings, cleaned IAW MIL STD 1622B22
F3.7.3.672SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide M83248/2-908 O-rings, cleaned IAW MIL STD 1622B44

F 3.7.4 73 SNDL Maintenance 1 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. 4 HRS 4 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

F3.7.4.174SNDL Maintenance136M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.Labor involved in SNDL HP oxygen reducing station valve inspection (panel removal, piping removal/reinstallation, panel reinstallation, joint testing)4 HRS4 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.4.275SNDL Maintenance136M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.Visually inspect primary HP oxygen supply regulator OHP-R206 and secondary HP oxygen supply regulator OHP-R205 inlet screens11
F3.7.4.376SNDL Maintenance136M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.Visually inspect primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 outlets11
F3.7.4.477SNDL Maintenance136M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.Overhaul primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V2034 HRS4 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.4.578SNDL Maintenance136M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.Provide valve repair kit (p/n T-9K-6N)11
F3.7.4.679SNDL Maintenance136M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.Clean (2) valve repair kits IAW MIL STD 1330E2, 2 HRS EA2, 4 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.4.780SNDL Maintenance136M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.Perform valve seat tightness test on primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V2031 HR1 HRFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

F 3.7.5 81 SNDL Maintenance 1 36M Test Relief Valves Removed from System 7 7

F3.7.682SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and Housings33Main service item. Same colored row(s) immediately below indicate required supporting parts.
F3.7.6.183SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and HousingsProvide Swagelok filter element (p/n M-8F-K4-15)33
F3.7.6.284SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and HousingsProvide Swagelok filter gaskets (p/n SS-8TF-K2)33
F3.7.6.385SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and HousingsClean (3) filters and (3) gaskets IAW MIL STD 1330E33

F 3.7.7 86 SNDL Maintenance 1 36M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter Element 3 HRS 3 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

F3.7.7.187SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter ElementProvide Norman filter element (p/n 416G-20VN)22
F3.7.7.288SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter ElementClean (2) filter elements IAW MIL STD 1622B2, 2 HRS EA2, 4 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.7.389SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter ElementProvide M83248/2-924 O-rings, cleaned IAW MIL STD 1622B44
F3.7.7.490SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter ElementProvide M83248/2-912 O-rings, cleaned IAW MIL STD 1622B44
F3.7.7.591SNDL Maintenance136M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter ElementProvide M83248/2-021 O-rings, cleaned IAW MIL STD 1622B88

F 3.7.8 92 SNDL Maintenance 1 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA 2 HRS 2 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

F3.7.8.193SNDL Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide filter element (p/n U-10007)22
F3.7.8.294SNDL Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAClean (2) filter elements IAW MIL STD 1622B22 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.8.395SNDL Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B44
F3.7.8.496SNDL Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B44
F3.7.8.597SNDL Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B22
F3.7.998SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement99Main service item. Same colored row(s) immediately below indicate required supporting parts.
F3.7.9.199SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementLabor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test9, 16 HRS EA9, 144 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.9.2100SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide rupture discs (p/n 128450XX)99
F3.7.9.3101SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementClean (9) rupture discs IAW MIL STD 1622B9, 1 HR EA9, 9 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.9.4102SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D1515
F3.7.9.5103SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D1818
F3.7.9.6104SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D1717
F3.7.9.7105SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementDiver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source)11
F3.7.9.8106SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementU-2 Hydrostatically Test Hose10 HRS10 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.9.9107SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementU-4 Repair or Replace ASRA Check Valve (AHP-V445) and Conduct Tightness Tests22
F3.7.9.10108SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide Swagelok check valve (p/n SS-CHVCO8-5)11
F3.7.9.11109SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementU-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffuser(s)/Silencer2, 2 HRS EA2, 4 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.9.12110SNDL Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementREC and OQE package9, 4 HRS EA36 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

CATEGORY F SUBTOTAL $ - 0

G 3.8.1 111 FADS III Maintenance 1 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite 12 12

G 3.8.2 112 FADS III Maintenance 1 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements 1 HR 1 HR Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

G3.8.2.1113FADS III Maintenance136M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter ElementsProvide filter element (p/n U-10007)11
G3.8.2.2114FADS III Maintenance136M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter ElementsClean (4) filter elements IAW MIL STD 1622B4, 1 HR EA4, 4 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
G3.8.2.3115FADS III Maintenance136M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter ElementsProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B66
G3.8.2.4116FADS III Maintenance136M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter ElementsProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B11
G3.8.2.5117FADS III Maintenance136M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter ElementsProvide M83248/2-111 O-rings, cleaned IAW MIL STD 1622B22

G 3.8.3 118 FADS III Maintenance 1 36M Test Relief Valves Removed from System onsite 4 4

G 3.8.4 119 FADS III Maintenance 1 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA 1 HR 1 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

G3.8.4.1120FADS III Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide filter element (p/n U-10007)11
G3.8.4.2121FADS III Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAClean (4) filter elements IAW MIL STD 1622B4, 1 HR EA4, 4 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
G3.8.4.3122FADS III Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B22
G3.8.4.4123FADS III Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B11
G3.8.4.5124FADS III Maintenance136M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBAProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B11
G3.8.5125FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement99Main service item. Same colored row(s) immediately below indicate required supporting parts.
G3.8.5.1126FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementLabor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test1616 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
G3.8.5.2127FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide rupture discs (p/n 128450XX)99
G3.8.5.3128FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementClean (9) rupture discs IAW MIL STD 1622B9, 1 HR EA9, 9 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
G3.8.5.4129FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D1515
G3.8.5.5130FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D1818
G3.8.5.6131FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D1717
G3.8.5.7132FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementDiver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source)11
G3.8.5.8133FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementU-2 Hydrostatically Test Hoses5 HRS5 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
G3.8.5.9134FADS III Maintenance160M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementREC and OQE package9, 4 HRS EA36 HRS TOTALFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

CATEGORY G SUBTOTAL $ - 0

H3.9.1135ORCA Maintenance124M Calibrate Diver's Life Support System (DLSS) Installed Gauges22
H3.9.2136ORCA Maintenance136M Test Relief Valves Removed From System11
H3.9.3137ORCA Maintenance136M Clean and Inspect Oxygen Regulating Console Assembly (ORCA) I & II Inline Filter Elements3 HRS3 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
H3.9.4138ORCA Maintenance1U-2 Hydrostatically Test Hoses2 HRS2 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
H3.9.5139ORCA Maintenance1REC and OQE package2 HRS2 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
CATEGORY H SUBTOTAL$ - 0
I3.10140DLSS Relief Valves20036M Test Relief Valves Removed from System onsite200
CATEGORY I SUBTOTAL$ - 0
J3.11141SCUBA Cylinders30060M Hydrostatic test SCUBA cylinders300
CATEGORY J SUBTOTAL$ - 0
K3.12.1142DLSS Gauges40018M 6R Calibrate Diver's Life Support System (DLSS) Portable Gauges400
K3.12.2143DLSS Gauges40024M Calibrate Diver's Life Support System (DLSS) Installed Gauges400
CATEGORY K SUBTOTAL$ - 0
L3.13.1144Closed Circuit UBA Viper224M Calibrate Test Panel Gages, Relief Valve, and Conduct Comparison Accuracy Test for Flowmeters and Pocket Flowmeters.24
L3.13.2145Closed Circuit UBA Viper260M Deliver Pressure Vessels to an Authorized Activity for Hydrostatic Testing.2 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
CATEGORY L SUBTOTAL$ - 0
BASE YEAR ANNUAL TOTAL$ - 0

OPTION YEAR 1

EODGRU1 DIVERS LIFE SUPPORT SYSTEMS (DLSS) MAINTENANCE REQUIREMENTS WITH PARTS LIST
CategoryPWS SectionLine Item No.Category Description# of AssetsDescriptionAssociated Item(s)/Part Number(s)Quantity per AssetTotal Quantity Serviced
(based on an annual basis unless specified otherwise)NotesUnit PriceUnit (i.e., Each, Group)Extended Price
A3.2.11Gas Cylinders50Refill HeO2 88/12% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees.50
A3.2.22Gas Cylinders30Refill O2 100% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees.30
A3.2.33Gas Cylinders20Refill O2N2 60/40% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees.20
CATEGORY A SUBTOTAL$ - 0

B 3.3.1 4 Oxygen Transfer Pump Assembly (OTPA) Maintenance 3 24M Calibrate oxygen outlet pressure gauge OHP-G201 3 9

B3.3.25Oxygen Transfer Pump Assembly (OTPA) Maintenance324M Replace Pump Assembly Air Cycling Valve O-rings and Bumper39
B3.3.2.16Oxygen Transfer Pump Assembly (OTPA) Maintenance324M Replace Pump Assembly Air Cycling Valve O-rings and BumperProvide air cycling valve kit (p/n 17329)39
B3.3.37Oxygen Transfer Pump Assembly (OTPA) Maintenance336M Test Oxygen Transfer Pump Assembly Relief Valves39
B3.3.48Oxygen Transfer Pump Assembly (OTPA) Maintenance336M Inspect Oxygen In-Line Filters26
B3.3.59Oxygen Transfer Pump Assembly (OTPA) Maintenance372M Deliver Oxygen Transfer Pump Assembly for Overhaul13
CATEGORY B SUBTOTAL$ - 0
C3.4.110Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge312Main service item. Same colored row(s) immediately below indicate required supporting parts.
C3.4.1.111Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide drying filter cartridge (p/n 058825A)28
C3.4.1.212Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide Securus filter cartridge (p/n 060037A)14
C3.4.1.313Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide O-ring (p/n N04735)312
C3.4.1.414Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide backup ring (p/n N04736)312
C3.4.1.515Bauer O26-D Compressor Maintenance4A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter CartridgeProvide air intake filter (p/n N25886)14

C 3.4.2 16 Bauer O26-D Compressor Maintenance 4 18M Calibrate Diver's Portable Gauges 4

C 3.4.3 17 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element 10 HRS 40 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

C 3.4.3.1 18 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element Provide sintered filter element (p/n 061860) 1 4

C3.4.419Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter Assembly28Main service item. Same colored row(s) immediately below indicate required supporting parts.
C3.4.4.120Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide oil filter (p/n N25326)14
C3.4.4.221Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide gasket (p/n 077774)14
C3.4.4.322Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide O-ring (p/n N04058)14
C3.4.4.423Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide O-ring (p/n N25327)14
C3.4.4.524Bauer O26-D Compressor Maintenance424M Change Oil and Replace Oil Tube/Filter AssemblyProvide compressor oil (p/n OIL-0024)28
C3.4.525Bauer O26-D Compressor Maintenance424M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves28Main service item. Same colored row(s) immediately below indicate required supporting parts.
C3.4.5.126Bauer O26-D Compressor Maintenance424M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check ValvesProvide check valve (p/n VAL-0007)28
C3.4.5.227Bauer O26-D Compressor Maintenance424M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check ValvesProvide pressure maintaining valve (p/n VAL-0053)14
C3.4.628Bauer O26-D Compressor Maintenance436M Test Relief Valves Removed From System4
CATEGORY C SUBTOTAL$ - 0
D3.5.129Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier element15Main service item. Same colored row(s) immediately below indicate required supporting parts.
D3.5.1.130Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide air purifier element (p/n 058821A)15
D3.5.1.231Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide O-ring (p/n N04735)15
D3.5.1.332Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide backup ring (p/n N04736)15
D3.5.1.433Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementA-11 Change CO/Moisture indicator element15
D3.5.1.534Bauer C-D/DV/Navy Compressor Maintenance5A-10 Replace Bauer air purifier elementProvide moisture indicator element (p/n ELM-0056)15
D3.5.235Bauer C-D/DV/Navy Compressor Maintenance518M Calibrate Diver's Portable Gauges210
D3.5.336Bauer C-D/DV/Navy Compressor Maintenance536M Test Relief Valves Removed From System210
CATEGORY D SUBTOTAL$ - 0
E3.6.137Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite2472Main service item. Same colored row(s) immediately below indicate required supporting parts.
E3.6.1.138Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsiteLabor involved in TRCS calibration (relief valve removal, system line-ups, joint testing)1854
E3.6.1.239Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsiteProvide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal)618
E3.6.1.340Transportable Recompression Chamber System (TRCS)324M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsiteProvide AS3581-010 O-rings, cleaned IAW MIL STD 1330D (for TRCS med-lock gauge)13

E 3.6.2 41 Transportable Recompression Chamber System (TRCS) 3 36M Perform Visual Inspection of Acrylic Window 5 15

E3.6.342Transportable Recompression Chamber System (TRCS)336M Test Relief Valves Removed from System onsite824Main service item. Same colored row(s) immediately below indicate required supporting parts.
E3.6.3.143Transportable Recompression Chamber System (TRCS)336M Test Relief Valves Removed from System onsiteLabor involved in TRCS calibration (relief valve removal, system line-ups, joint testing)6 HRS18 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.3.244Transportable Recompression Chamber System (TRCS)336M Test Relief Valves Removed from System onsiteProvide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal)618

E 3.6.4 45 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings 5 HRS 15 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

E3.6.4.146Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and HousingsProvide Swagelok filter element (p/n M-8F-K4-15)515
E3.6.4.247Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and HousingsProvide Swagelok filter gasket (p/n SS-8TF-K2)515
E3.6.4.348Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and HousingsClean filter elements and gaskets IAW MIL STD 1330E6 HRS18 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

E 3.6.5 49 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings 6 HRS 18 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

E3.6.5.150Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transfer Lock (TL) T-Filter Elements and HousingsProvide Swagelok filter element (p/n M-8F-K4-15)412
E3.6.5.251Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transfer Lock (TL) T-Filter Elements and HousingsProvide Swagelok filter gasket (p/n SS-8TF-K2)412
E3.6.5.352Transportable Recompression Chamber System (TRCS)336M Clean and Inspect Transfer Lock (TL) T-Filter Elements and HousingsClean filter elements and gaskets IAW MIL STD 1330E6 HRS18 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.653Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement1236Main service item. Same colored row(s) immediately below indicate required supporting parts.
E3.6.6.154Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementLabor to disassemble and reassemble (4) flask racks assemblies while maintaining cleanliness IAW MIL STD 1330E, including filling flasks for 24 hour joint tightness drop test12 HRS36 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.6.255Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide rupture discs (p/n 20Z), cleaned IAW MIL STD1330E1236
E3.6.6.356Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-916 o-rings, cleaned IAW MIL STD 1330E1236
E3.6.6.457Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementProvide M83248/2-010 O-rings, cleaned IAW MIL STD 1330E1236
E3.6.6.558Transportable Recompression Chamber System (TRCS)360M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc ReplacementDiver’s air gas required for flask rack joint tightness test (leave flasks full and provide current satisfactory air sample from diver’s air source)13
E3.6.759Transportable Recompression Chamber System (TRCS)360M Hydrostatically Test Fire Extinguisher13
E3.6.860Transportable Recompression Chamber System (TRCS)3U-2 Hydrostatically Test Hoses5 HRS15 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.961Transportable Recompression Chamber System (TRCS)3U-3 Clean and Inspect Interlock Poppet and NATO Flange Bearings8 HRS24 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.1062Transportable Recompression Chamber System (TRCS)3U-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffusers/Silencers3 HRS9 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
E3.6.1163Transportable Recompression Chamber System (TRCS)3REC and OQE package4 HRS12 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
CATEGORY E SUBTOTAL$ - 0
F3.7.164SNDL Maintenance118M Test and Inspect ASRA Check Valve (AHP-V445)1
F3.7.265SNDL Maintenance124M Calibrate Diver's Life Support System (DLSS) Installed Gauges2222

F 3.7.3 66 SNDL Maintenance 1 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element 2 HRS 2 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.

For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.

F3.7.3.167SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide filter element (p/n U-10007)22
F3.7.3.268SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementClean (2) filter elements IAW MIL STD 1622B22 HRSFor quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
F3.7.3.369SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B22
F3.7.3.470SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B22
F3.7.3.571SNDL Maintenance136M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter ElementProvide M83248/2-015 O-rings, cleaned IAW MIL STD 1622B22