2.07a 26Q4023_Att3_PWS_Att1_Service List.xlsx
XLSX spreadsheet 64 KB Posted
- Attached to
- DIVERS LIFE SUPPORT SYSTEM MAINTENANCE SERVICES
- Solicitation number
- N0060426Q4023
About this file
This is a Performance Work Statement (PWS) Attachment detailing comprehensive maintenance requirements and parts lists for Divers Life Support Systems (DLSS) equipment in support of Explosive Ordnance Disposal Group One (EODGRU1) located in San Diego, California.
The document specifies annual maintenance service requirements across eight major equipment categories: Gas Cylinders (refilling HeO2, O2, and O2N2 compressed gas cylinders); Oxygen Transfer Pump Assembly (OTPA) maintenance including calibration, valve replacement, and overhaul delivery; Bauer O26-D and Bauer C-D/DV/Navy Compressor maintenance with filter and valve servicing; Transportable Recompression Chamber System (TRCS) with quarterly and semi-annual calibration, filter cleaning, and hydrostatic testing of carbon fiber flasks; Standard Navy Double Lock (SNDL) recompression chamber system maintenance including filter and valve inspection; FADS III console maintenance; ORCA (Oxygen Regulating Console Assembly) maintenance; plus standalone relief valve testing, SCUBA cylinder hydrostatic testing, gauge calibration, and Closed Circuit UBA Viper equipment servicing. Each line item specifies the number of assets, maintenance interval (ranging from 18 months to 72 months), detailed task descriptions, associated part numbers with quantities required per asset and total annual quantities, and labor hour estimates where applicable. Service intervals are designated by codes such as 18M (18 months), 24M (24 months), 36M (36 months), 60M (60 months), and 72M (72 months), with specific maintenance cycles for different equipment requiring calibration, cleaning, inspection, testing, and component replacement performed in accordance with applicable military standards including MIL STD 1330D, 1330E, and 1622B. The parts list includes O-rings, filter elements, rupture discs, valve components, gaskets, and specialty items such as Swagelok filters and various regulator components.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2.03 26Q4023_Amd1_Att8_QandA.pdf | ||
| 2.07a 26Q4023_Att4_FAR_DFARS.pdf | ||
| 2.07a 26Q4023_Att7_PricingWksht.xlsx | XLSX spreadsheet | |
| 2.07 26Q4023_Att1_Comb SS.pdf | ||
| 2.07a 26Q4023_Att6_QASP_Log.xlsx | XLSX spreadsheet | |
| 2.07a 26Q4023_Att5_QASP.pdf | ||
| 2.07a 26Q4023_Att2_PWS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BASE YEAR
| EODGRU1 DIVERS LIFE SUPPORT SYSTEMS (DLSS) MAINTENANCE REQUIREMENTS WITH PARTS LIST | |||||||||
| Category | PWS Section | Line Item No. | Category Description | # of Assets | Description | Associated Item(s)/Part Number(s) | Quantity per Asset | Total Quantity Serviced | |
| (based on an annual basis unless specified otherwise) | Notes | ||||||||
| A | 3.2.1 | 1 | Gas Cylinders | 50 | Refill HeO2 88/12% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees. | 50 | |||
| A | 3.2.2 | 2 | Gas Cylinders | 30 | Refill O2 100% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees. | 30 | |||
| A | 3.2.3 | 3 | Gas Cylinders | 20 | Refill O2N2 60/40% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees. | 20 |
B 3.3.1 4 Oxygen Transfer Pump Assembly (OTPA) Maintenance 3 24M Calibrate oxygen outlet pressure gauge OHP-G201 3 9
| B | 3.3.2 | 5 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 24M Replace Pump Assembly Air Cycling Valve O-rings and Bumper | 3 | 9 | |
| B | 3.3.2.1 | 6 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 24M Replace Pump Assembly Air Cycling Valve O-rings and Bumper | Provide air cycling valve kit (p/n 17329) | 3 | 9 |
| B | 3.3.3 | 7 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 36M Test Oxygen Transfer Pump Assembly Relief Valves | 3 | 9 |
| B | 3.3.4 | 8 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 36M Inspect Oxygen In-Line Filters | 2 | 6 |
| B | 3.3.5 | 9 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 72M Deliver Oxygen Transfer Pump Assembly for Overhaul | 1 | 3 |
| C | 3.4.1 | 10 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | 3 | 12 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| C | 3.4.1.1 | 11 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide drying filter cartridge (p/n 058825A) | 2 | 8 | |
| C | 3.4.1.2 | 12 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide Securus filter cartridge (p/n 060037A) | 1 | 4 | |
| C | 3.4.1.3 | 13 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide O-ring (p/n N04735) | 3 | 12 | |
| C | 3.4.1.4 | 14 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide backup ring (p/n N04736) | 3 | 12 | |
| C | 3.4.1.5 | 15 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide air intake filter (p/n N25886) | 1 | 4 |
C 3.4.2 16 Bauer O26-D Compressor Maintenance 4 18M Calibrate Diver's Portable Gauges 4
C 3.4.3 17 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element 10 HRS 40 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
C 3.4.3.1 18 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element Provide sintered filter element (p/n 061860) 1 4
| C | 3.4.4 | 19 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | 2 | 8 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| C | 3.4.4.1 | 20 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide oil filter (p/n N25326) | 1 | 4 | |
| C | 3.4.4.2 | 21 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide gasket (p/n 077774) | 1 | 4 | |
| C | 3.4.4.3 | 22 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide O-ring (p/n N04058) | 1 | 4 | |
| C | 3.4.4.4 | 23 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide O-ring (p/n N25327) | 1 | 4 | |
| C | 3.4.4.5 | 24 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide compressor oil (p/n OIL-0024) | 2 | 8 |
| C | 3.4.5 | 25 | Bauer O26-D Compressor Maintenance | 4 | 24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves | 2 | 8 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| C | 3.4.5.1 | 26 | Bauer O26-D Compressor Maintenance | 4 | 24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves | Provide check valve (p/n VAL-0007) | 2 | 8 | |
| C | 3.4.5.2 | 27 | Bauer O26-D Compressor Maintenance | 4 | 24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves | Provide pressure maintaining valve (p/n VAL-0053) | 1 | 4 |
C 3.4.6 28 Bauer O26-D Compressor Maintenance 4 36M Test Relief Valves Removed From System 4
| D | 3.5.1 | 29 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | 1 | 5 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| D | 3.5.1.1 | 30 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide air purifier element (p/n 058821A) | 1 | 5 | |
| D | 3.5.1.2 | 31 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide O-ring (p/n N04735) | 1 | 5 | |
| D | 3.5.1.3 | 32 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide backup ring (p/n N04736) | 1 | 5 | |
| D | 3.5.1.4 | 33 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | A-11 Change CO/Moisture indicator element | 1 | 5 | |
| D | 3.5.1.5 | 34 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide moisture indicator element (p/n ELM-0056) | 1 | 5 |
| D | 3.5.2 | 35 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | 18M Calibrate Diver's Portable Gauges | 2 | 10 |
| D | 3.5.3 | 36 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | 36M Test Relief Valves Removed From System | 2 | 10 |
| E | 3.6.1 | 37 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | 24 | 72 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| E | 3.6.1.1 | 38 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | Labor involved in TRCS calibration (relief valve removal, system line-ups, joint testing) | 18 | 54 | |
| E | 3.6.1.2 | 39 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | Provide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal) | 6 | 18 | |
| E | 3.6.1.3 | 40 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | Provide AS3581-010 O-rings, cleaned IAW MIL STD 1330D (for TRCS med-lock gauge) | 1 | 3 |
E 3.6.2 41 Transportable Recompression Chamber System (TRCS) 3 36M Perform Visual Inspection of Acrylic Window 5 15
| E | 3.6.3 | 42 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Test Relief Valves Removed from System onsite | 8 | 24 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| E | 3.6.3.1 | 43 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Test Relief Valves Removed from System onsite | Labor involved in TRCS calibration (relief valve removal, system line-ups, joint testing) | 6 HRS | 18 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.3.2 | 44 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Test Relief Valves Removed from System onsite | Provide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal) | 6 | 18 |
E 3.6.4 45 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings 5 HRS 15 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| E | 3.6.4.1 | 46 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings | Provide Swagelok filter element (p/n M-8F-K4-15) | 5 | 15 | |
| E | 3.6.4.2 | 47 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings | Provide Swagelok filter gasket (p/n SS-8TF-K2) | 5 | 15 | |
| E | 3.6.4.3 | 48 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings | Clean filter elements and gaskets IAW MIL STD 1330E | 6 HRS | 18 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
E 3.6.5 49 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings 6 HRS 18 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| E | 3.6.5.1 | 50 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings | Provide Swagelok filter element (p/n M-8F-K4-15) | 4 | 12 | |
| E | 3.6.5.2 | 51 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings | Provide Swagelok filter gasket (p/n SS-8TF-K2) | 4 | 12 | |
| E | 3.6.5.3 | 52 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings | Clean filter elements and gaskets IAW MIL STD 1330E | 6 HRS | 18 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.6 | 53 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | 12 | 36 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| E | 3.6.6.1 | 54 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Labor to disassemble and reassemble (4) flask racks assemblies while maintaining cleanliness IAW MIL STD 1330E, including filling flasks for 24 hour joint tightness drop test | 12 HRS | 36 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.6.2 | 55 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide rupture discs (p/n 20Z), cleaned IAW MIL STD1330E | 12 | 36 | |
| E | 3.6.6.3 | 56 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-916 o-rings, cleaned IAW MIL STD 1330E | 12 | 36 | |
| E | 3.6.6.4 | 57 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-010 O-rings, cleaned IAW MIL STD 1330E | 12 | 36 | |
| E | 3.6.6.5 | 58 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Diver’s air gas required for flask rack joint tightness test (leave flasks full and provide current satisfactory air sample from diver’s air source) | 1 | 3 |
| E | 3.6.7 | 59 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Hydrostatically Test Fire Extinguisher | 1 | 3 | |
| E | 3.6.8 | 60 | Transportable Recompression Chamber System (TRCS) | 3 | U-2 Hydrostatically Test Hoses | 5 HRS | 15 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.9 | 61 | Transportable Recompression Chamber System (TRCS) | 3 | U-3 Clean and Inspect Interlock Poppet and NATO Flange Bearings | 8 HRS | 24 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.10 | 62 | Transportable Recompression Chamber System (TRCS) | 3 | U-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffusers/Silencers | 3 HRS | 9 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.11 | 63 | Transportable Recompression Chamber System (TRCS) | 3 | REC and OQE package | 4 HRS | 12 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.1 | 64 | SNDL Maintenance | 1 | 18M Test and Inspect ASRA Check Valve (AHP-V445) | 1 | |
| F | 3.7.2 | 65 | SNDL Maintenance | 1 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges | 22 | 22 |
F 3.7.3 66 SNDL Maintenance 1 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element 2 HRS 2 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| F | 3.7.3.1 | 67 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide filter element (p/n U-10007) | 2 | 2 | |
| F | 3.7.3.2 | 68 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Clean (2) filter elements IAW MIL STD 1622B | 2 | 2 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.3.3 | 69 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 | |
| F | 3.7.3.4 | 70 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 | |
| F | 3.7.3.5 | 71 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-015 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 | |
| F | 3.7.3.6 | 72 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-908 O-rings, cleaned IAW MIL STD 1622B | 4 | 4 |
F 3.7.4 73 SNDL Maintenance 1 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. 4 HRS 4 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| F | 3.7.4.1 | 74 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Labor involved in SNDL HP oxygen reducing station valve inspection (panel removal, piping removal/reinstallation, panel reinstallation, joint testing) | 4 HRS | 4 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.4.2 | 75 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Visually inspect primary HP oxygen supply regulator OHP-R206 and secondary HP oxygen supply regulator OHP-R205 inlet screens | 1 | 1 | |
| F | 3.7.4.3 | 76 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Visually inspect primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 outlets | 1 | 1 | |
| F | 3.7.4.4 | 77 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Overhaul primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 | 4 HRS | 4 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.4.5 | 78 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Provide valve repair kit (p/n T-9K-6N) | 1 | 1 | |
| F | 3.7.4.6 | 79 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Clean (2) valve repair kits IAW MIL STD 1330E | 2, 2 HRS EA | 2, 4 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.4.7 | 80 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Perform valve seat tightness test on primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 | 1 HR | 1 HR | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
F 3.7.5 81 SNDL Maintenance 1 36M Test Relief Valves Removed from System 7 7
| F | 3.7.6 | 82 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and Housings | 3 | 3 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| F | 3.7.6.1 | 83 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and Housings | Provide Swagelok filter element (p/n M-8F-K4-15) | 3 | 3 | |
| F | 3.7.6.2 | 84 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and Housings | Provide Swagelok filter gaskets (p/n SS-8TF-K2) | 3 | 3 | |
| F | 3.7.6.3 | 85 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) T-Filter Elements and Housings | Clean (3) filters and (3) gaskets IAW MIL STD 1330E | 3 | 3 |
F 3.7.7 86 SNDL Maintenance 1 36M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter Element 3 HRS 3 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| F | 3.7.7.1 | 87 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter Element | Provide Norman filter element (p/n 416G-20VN) | 2 | 2 | |
| F | 3.7.7.2 | 88 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter Element | Clean (2) filter elements IAW MIL STD 1622B | 2, 2 HRS EA | 2, 4 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.7.3 | 89 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter Element | Provide M83248/2-924 O-rings, cleaned IAW MIL STD 1622B | 4 | 4 | |
| F | 3.7.7.4 | 90 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter Element | Provide M83248/2-912 O-rings, cleaned IAW MIL STD 1622B | 4 | 4 | |
| F | 3.7.7.5 | 91 | SNDL Maintenance | 1 | 36M Clean and Inspect Standard Navy Double Lock (SNDL) LP In-Line Filter Element | Provide M83248/2-021 O-rings, cleaned IAW MIL STD 1622B | 8 | 8 |
F 3.7.8 92 SNDL Maintenance 1 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA 2 HRS 2 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| F | 3.7.8.1 | 93 | SNDL Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide filter element (p/n U-10007) | 2 | 2 | |
| F | 3.7.8.2 | 94 | SNDL Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Clean (2) filter elements IAW MIL STD 1622B | 2 | 2 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.8.3 | 95 | SNDL Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B | 4 | 4 | |
| F | 3.7.8.4 | 96 | SNDL Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | 4 | 4 | |
| F | 3.7.8.5 | 97 | SNDL Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 |
| F | 3.7.9 | 98 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | 9 | 9 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| F | 3.7.9.1 | 99 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Labor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test | 9, 16 HRS EA | 9, 144 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.9.2 | 100 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide rupture discs (p/n 128450XX) | 9 | 9 | |
| F | 3.7.9.3 | 101 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Clean (9) rupture discs IAW MIL STD 1622B | 9, 1 HR EA | 9, 9 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.9.4 | 102 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D | 15 | 15 | |
| F | 3.7.9.5 | 103 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D | 18 | 18 | |
| F | 3.7.9.6 | 104 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D | 17 | 17 | |
| F | 3.7.9.7 | 105 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Diver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source) | 1 | 1 | |
| F | 3.7.9.8 | 106 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | U-2 Hydrostatically Test Hose | 10 HRS | 10 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.9.9 | 107 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | U-4 Repair or Replace ASRA Check Valve (AHP-V445) and Conduct Tightness Tests | 2 | 2 | |
| F | 3.7.9.10 | 108 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide Swagelok check valve (p/n SS-CHVCO8-5) | 1 | 1 | |
| F | 3.7.9.11 | 109 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | U-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffuser(s)/Silencer | 2, 2 HRS EA | 2, 4 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.9.12 | 110 | SNDL Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | REC and OQE package | 9, 4 HRS EA | 36 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
G 3.8.1 111 FADS III Maintenance 1 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite 12 12
G 3.8.2 112 FADS III Maintenance 1 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements 1 HR 1 HR Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| G | 3.8.2.1 | 113 | FADS III Maintenance | 1 | 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements | Provide filter element (p/n U-10007) | 1 | 1 | |
| G | 3.8.2.2 | 114 | FADS III Maintenance | 1 | 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements | Clean (4) filter elements IAW MIL STD 1622B | 4, 1 HR EA | 4, 4 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| G | 3.8.2.3 | 115 | FADS III Maintenance | 1 | 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | 6 | 6 | |
| G | 3.8.2.4 | 116 | FADS III Maintenance | 1 | 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | 1 | 1 | |
| G | 3.8.2.5 | 117 | FADS III Maintenance | 1 | 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements | Provide M83248/2-111 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 |
G 3.8.3 118 FADS III Maintenance 1 36M Test Relief Valves Removed from System onsite 4 4
G 3.8.4 119 FADS III Maintenance 1 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA 1 HR 1 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| G | 3.8.4.1 | 120 | FADS III Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide filter element (p/n U-10007) | 1 | 1 | |
| G | 3.8.4.2 | 121 | FADS III Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Clean (4) filter elements IAW MIL STD 1622B | 4, 1 HR EA | 4, 4 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| G | 3.8.4.3 | 122 | FADS III Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 | |
| G | 3.8.4.4 | 123 | FADS III Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | 1 | 1 | |
| G | 3.8.4.5 | 124 | FADS III Maintenance | 1 | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | 1 | 1 |
| G | 3.8.5 | 125 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | 9 | 9 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| G | 3.8.5.1 | 126 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Labor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test | 16 | 16 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| G | 3.8.5.2 | 127 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide rupture discs (p/n 128450XX) | 9 | 9 | |
| G | 3.8.5.3 | 128 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Clean (9) rupture discs IAW MIL STD 1622B | 9, 1 HR EA | 9, 9 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| G | 3.8.5.4 | 129 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D | 15 | 15 | |
| G | 3.8.5.5 | 130 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D | 18 | 18 | |
| G | 3.8.5.6 | 131 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D | 17 | 17 | |
| G | 3.8.5.7 | 132 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Diver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source) | 1 | 1 | |
| G | 3.8.5.8 | 133 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | U-2 Hydrostatically Test Hoses | 5 HRS | 5 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| G | 3.8.5.9 | 134 | FADS III Maintenance | 1 | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | REC and OQE package | 9, 4 HRS EA | 36 HRS TOTAL | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| H | 3.9.1 | 135 | ORCA Maintenance | 1 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges | 2 | 2 | |
| H | 3.9.2 | 136 | ORCA Maintenance | 1 | 36M Test Relief Valves Removed From System | 1 | 1 | |
| H | 3.9.3 | 137 | ORCA Maintenance | 1 | 36M Clean and Inspect Oxygen Regulating Console Assembly (ORCA) I & II Inline Filter Elements | 3 HRS | 3 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| H | 3.9.4 | 138 | ORCA Maintenance | 1 | U-2 Hydrostatically Test Hoses | 2 HRS | 2 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| H | 3.9.5 | 139 | ORCA Maintenance | 1 | REC and OQE package | 2 HRS | 2 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
I 3.10 140 DLSS Relief Valves 200 36M Test Relief Valves Removed from System onsite 200
J 3.11 141 SCUBA Cylinders 300 60M Hydrostatic test SCUBA cylinders 300
| K | 3.12.1 | 142 | DLSS Gauges | 400 | 18M 6R Calibrate Diver's Life Support System (DLSS) Portable Gauges | 400 |
| K | 3.12.2 | 143 | DLSS Gauges | 400 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges | 400 |
| L | 3.13.1 | 144 | Closed Circuit UBA Viper | 2 | 24M Calibrate Test Panel Gages, Relief Valve, and Conduct Comparison Accuracy Test for Flowmeters and Pocket Flowmeters. | 2 | 4 | |
| L | 3.13.2 | 145 | Closed Circuit UBA Viper | 2 | 60M Deliver Pressure Vessels to an Authorized Activity for Hydrostatic Testing. | 2 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
OY1
| EODGRU1 DIVERS LIFE SUPPORT SYSTEMS (DLSS) MAINTENANCE REQUIREMENTS WITH PARTS LIST | |||||||||
| Category | PWS Section | Line Item No. | Category Description | # of Assets | Description | Associated Item(s)/Part Number(s) | Quantity per Asset | Total Quantity Serviced | |
| (based on an annual basis unless specified otherwise) | Notes | ||||||||
| A | 3.2.1 | 1 | Gas Cylinders | 50 | Refill HeO2 88/12% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees. | 50 | |||
| A | 3.2.2 | 2 | Gas Cylinders | 30 | Refill O2 100% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees. | 30 | |||
| A | 3.2.3 | 3 | Gas Cylinders | 20 | Refill O2N2 60/40% compressed gas cylinders (certificate of gas analysis included). Fill should include any associated fees. | 20 |
B 3.3.1 4 Oxygen Transfer Pump Assembly (OTPA) Maintenance 3 24M Calibrate oxygen outlet pressure gauge OHP-G201 3 9
| B | 3.3.2 | 5 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 24M Replace Pump Assembly Air Cycling Valve O-rings and Bumper | 3 | 9 | |
| B | 3.3.2.1 | 6 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 24M Replace Pump Assembly Air Cycling Valve O-rings and Bumper | Provide air cycling valve kit (p/n 17329) | 3 | 9 |
| B | 3.3.3 | 7 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 36M Test Oxygen Transfer Pump Assembly Relief Valves | 3 | 9 |
| B | 3.3.4 | 8 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 36M Inspect Oxygen In-Line Filters | 2 | 6 |
| B | 3.3.5 | 9 | Oxygen Transfer Pump Assembly (OTPA) Maintenance | 3 | 72M Deliver Oxygen Transfer Pump Assembly for Overhaul | 1 | 3 |
| C | 3.4.1 | 10 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | 3 | 12 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| C | 3.4.1.1 | 11 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide drying filter cartridge (p/n 058825A) | 2 | 8 | |
| C | 3.4.1.2 | 12 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide Securus filter cartridge (p/n 060037A) | 1 | 4 | |
| C | 3.4.1.3 | 13 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide O-ring (p/n N04735) | 3 | 12 | |
| C | 3.4.1.4 | 14 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide backup ring (p/n N04736) | 3 | 12 | |
| C | 3.4.1.5 | 15 | Bauer O26-D Compressor Maintenance | 4 | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | Provide air intake filter (p/n N25886) | 1 | 4 |
C 3.4.2 16 Bauer O26-D Compressor Maintenance 4 18M Calibrate Diver's Portable Gauges 4
C 3.4.3 17 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element 10 HRS 40 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
C 3.4.3.1 18 Bauer O26-D Compressor Maintenance 4 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element Provide sintered filter element (p/n 061860) 1 4
| C | 3.4.4 | 19 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | 2 | 8 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| C | 3.4.4.1 | 20 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide oil filter (p/n N25326) | 1 | 4 | |
| C | 3.4.4.2 | 21 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide gasket (p/n 077774) | 1 | 4 | |
| C | 3.4.4.3 | 22 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide O-ring (p/n N04058) | 1 | 4 | |
| C | 3.4.4.4 | 23 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide O-ring (p/n N25327) | 1 | 4 | |
| C | 3.4.4.5 | 24 | Bauer O26-D Compressor Maintenance | 4 | 24M Change Oil and Replace Oil Tube/Filter Assembly | Provide compressor oil (p/n OIL-0024) | 2 | 8 |
| C | 3.4.5 | 25 | Bauer O26-D Compressor Maintenance | 4 | 24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves | 2 | 8 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| C | 3.4.5.1 | 26 | Bauer O26-D Compressor Maintenance | 4 | 24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves | Provide check valve (p/n VAL-0007) | 2 | 8 | |
| C | 3.4.5.2 | 27 | Bauer O26-D Compressor Maintenance | 4 | 24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves | Provide pressure maintaining valve (p/n VAL-0053) | 1 | 4 |
C 3.4.6 28 Bauer O26-D Compressor Maintenance 4 36M Test Relief Valves Removed From System 4
| D | 3.5.1 | 29 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | 1 | 5 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| D | 3.5.1.1 | 30 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide air purifier element (p/n 058821A) | 1 | 5 | |
| D | 3.5.1.2 | 31 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide O-ring (p/n N04735) | 1 | 5 | |
| D | 3.5.1.3 | 32 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide backup ring (p/n N04736) | 1 | 5 | |
| D | 3.5.1.4 | 33 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | A-11 Change CO/Moisture indicator element | 1 | 5 | |
| D | 3.5.1.5 | 34 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | A-10 Replace Bauer air purifier element | Provide moisture indicator element (p/n ELM-0056) | 1 | 5 |
| D | 3.5.2 | 35 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | 18M Calibrate Diver's Portable Gauges | 2 | 10 |
| D | 3.5.3 | 36 | Bauer C-D/DV/Navy Compressor Maintenance | 5 | 36M Test Relief Valves Removed From System | 2 | 10 |
| E | 3.6.1 | 37 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | 24 | 72 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| E | 3.6.1.1 | 38 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | Labor involved in TRCS calibration (relief valve removal, system line-ups, joint testing) | 18 | 54 | |
| E | 3.6.1.2 | 39 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | Provide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal) | 6 | 18 | |
| E | 3.6.1.3 | 40 | Transportable Recompression Chamber System (TRCS) | 3 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | Provide AS3581-010 O-rings, cleaned IAW MIL STD 1330D (for TRCS med-lock gauge) | 1 | 3 |
E 3.6.2 41 Transportable Recompression Chamber System (TRCS) 3 36M Perform Visual Inspection of Acrylic Window 5 15
| E | 3.6.3 | 42 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Test Relief Valves Removed from System onsite | 8 | 24 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| E | 3.6.3.1 | 43 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Test Relief Valves Removed from System onsite | Labor involved in TRCS calibration (relief valve removal, system line-ups, joint testing) | 6 HRS | 18 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.3.2 | 44 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Test Relief Valves Removed from System onsite | Provide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal) | 6 | 18 |
E 3.6.4 45 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings 5 HRS 15 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| E | 3.6.4.1 | 46 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings | Provide Swagelok filter element (p/n M-8F-K4-15) | 5 | 15 | |
| E | 3.6.4.2 | 47 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings | Provide Swagelok filter gasket (p/n SS-8TF-K2) | 5 | 15 | |
| E | 3.6.4.3 | 48 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings | Clean filter elements and gaskets IAW MIL STD 1330E | 6 HRS | 18 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
E 3.6.5 49 Transportable Recompression Chamber System (TRCS) 3 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings 6 HRS 18 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| E | 3.6.5.1 | 50 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings | Provide Swagelok filter element (p/n M-8F-K4-15) | 4 | 12 | |
| E | 3.6.5.2 | 51 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings | Provide Swagelok filter gasket (p/n SS-8TF-K2) | 4 | 12 | |
| E | 3.6.5.3 | 52 | Transportable Recompression Chamber System (TRCS) | 3 | 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings | Clean filter elements and gaskets IAW MIL STD 1330E | 6 HRS | 18 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.6 | 53 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | 12 | 36 | Main service item. Same colored row(s) immediately below indicate required supporting parts. | |
| E | 3.6.6.1 | 54 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Labor to disassemble and reassemble (4) flask racks assemblies while maintaining cleanliness IAW MIL STD 1330E, including filling flasks for 24 hour joint tightness drop test | 12 HRS | 36 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.6.2 | 55 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide rupture discs (p/n 20Z), cleaned IAW MIL STD1330E | 12 | 36 | |
| E | 3.6.6.3 | 56 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-916 o-rings, cleaned IAW MIL STD 1330E | 12 | 36 | |
| E | 3.6.6.4 | 57 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Provide M83248/2-010 O-rings, cleaned IAW MIL STD 1330E | 12 | 36 | |
| E | 3.6.6.5 | 58 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | Diver’s air gas required for flask rack joint tightness test (leave flasks full and provide current satisfactory air sample from diver’s air source) | 1 | 3 |
| E | 3.6.7 | 59 | Transportable Recompression Chamber System (TRCS) | 3 | 60M Hydrostatically Test Fire Extinguisher | 1 | 3 | |
| E | 3.6.8 | 60 | Transportable Recompression Chamber System (TRCS) | 3 | U-2 Hydrostatically Test Hoses | 5 HRS | 15 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.9 | 61 | Transportable Recompression Chamber System (TRCS) | 3 | U-3 Clean and Inspect Interlock Poppet and NATO Flange Bearings | 8 HRS | 24 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.10 | 62 | Transportable Recompression Chamber System (TRCS) | 3 | U-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffusers/Silencers | 3 HRS | 9 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| E | 3.6.11 | 63 | Transportable Recompression Chamber System (TRCS) | 3 | REC and OQE package | 4 HRS | 12 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.1 | 64 | SNDL Maintenance | 1 | 18M Test and Inspect ASRA Check Valve (AHP-V445) | 1 | |
| F | 3.7.2 | 65 | SNDL Maintenance | 1 | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges | 22 | 22 |
F 3.7.3 66 SNDL Maintenance 1 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element 2 HRS 2 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| F | 3.7.3.1 | 67 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide filter element (p/n U-10007) | 2 | 2 | |
| F | 3.7.3.2 | 68 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Clean (2) filter elements IAW MIL STD 1622B | 2 | 2 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.3.3 | 69 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 | |
| F | 3.7.3.4 | 70 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 | |
| F | 3.7.3.5 | 71 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-015 O-rings, cleaned IAW MIL STD 1622B | 2 | 2 | |
| F | 3.7.3.6 | 72 | SNDL Maintenance | 1 | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | Provide M83248/2-908 O-rings, cleaned IAW MIL STD 1622B | 4 | 4 |
F 3.7.4 73 SNDL Maintenance 1 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. 4 HRS 4 HRS Main service item. Same colored row(s) immediately below indicate required supporting parts.
For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only.
| F | 3.7.4.1 | 74 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Labor involved in SNDL HP oxygen reducing station valve inspection (panel removal, piping removal/reinstallation, panel reinstallation, joint testing) | 4 HRS | 4 HRS | For quantities described in hours, hours are estimates based on historical information that are provided for informational purposes only. |
| F | 3.7.4.2 | 75 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Visually inspect primary HP oxygen supply regulator OHP-R206 and secondary HP oxygen supply regulator OHP-R205 inlet screens | 1 | 1 | |
| F | 3.7.4.3 | 76 | SNDL Maintenance | 1 | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | Visually inspect primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 outlets | 1 | 1 |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .