This file details a federal contract opportunity for expansion work at the South Bay International Wastewater Treatment Plant. The International Boundary and Water Commission U.S.-Mexico is soliciting bids under solicitation number 191BWC24R0001 to provide expansion services at the South Bay plant. Services required include asbestos surveying of existing facilities as outlined in the attached 00-31-26-01_1-4-A_2014_03_15_San_Ysidro_Asbestos_Survey.pdf file. Bids are due by the date specified in the solicitation documentation. The contract will be awarded to the responsible bidder whose bid, conforming to the solicitation, will be most advantageous to the government, with price and other factors considered.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS SURVEY REPORT
USIBWC San Ysidro Water Treatment Plant 2225 Dairy Mart Road
San Diego, CA 92108
Submitted to
U.S. International Boundary and Water Commission 4171 N. Mesa St., Suite C-100
El Paso, Texas 79902-1441
Issue Date: March 15, 2014
123 Technology Drive
Irvine, CA 92618 Telephone: 949.727.9336
TRC Project No: 212265
Asbestos Survey Report IBWC San Ysidro Water Treatment Plant, San Diego, CA March 15, 2014
Table of Contents
EXECUTIVE SUMMARY
ASBESTOS SURVEY
INTRODUCTION
PROJECT DESCRIPTION
SAMPLING AND ANALYTICAL PROCEDURES
INTERPRETATION OF ASBESTOS RESULTS
SAMPLED MATERIALS WHERE NO ASBESTOS WAS DETECTED
CONCLUSIONS AND RECOMMENDATIONS
DISCLAIMER
CERTIFICATION AND SIGNATORY PAGE
APPENDICES
Table 1.0 – Homogeneous Materials Summary
Appendix A - Bulk Asbestos Sample Laboratory Report
Appendix B - Sample Location Figures
Appendix C – Select Photographs
Appendix D - Inspector Certifications
EXECUTIVE SUMMARY
TRC Environmental Corporation (TRC) was contracted by the United States International Boundary and Water Commission (IBWC) to conduct an asbestos survey at the San Ysidro Waste Water Treatment Plant Buildings located at 2225 Dairy mart Road, San Diego, California. The asbestos survey comprised of surveying the accessible interior and exterior building materials of eleven (11) buildings at the Plant, three off site support buildings and the San Diego Field Office.
The survey consisted of identification of suspect building materials, assessment and quantification, collection of bulk samples of suspect asbestos containing materials, submittal of the collected samples for laboratory analysis and a report of the findings. The field asbestos survey was performed on February 13 and 14, 2012 by Mr. Sam Seneviratne, and assisted by Mr. Hector Gonzalez.
A Lead-based paint survey was not conducted at this facility based on the age of the facility. Lead-based paint was banned in residential and public buildings by the Consumer Product Safety Commission (CPSC) in 1977.
Asbestos was detected in concentrations exceeding one tenth of one percent (>0.1%) in the suspect asbestos containing materials sampled during the asbestos portion of the hazardous materials survey.
Tijuana River Flood Control Project Gauging Station
Sample Numbers Material Analytical
Results Approx
Quantity
NESHAP
Category
16-88 Roof Penetration
Mastic 20% Chrysotile <1 SF Cat II
Solids Thickening Building
Results Approx
Quantity
NESHAP
Category
11-168 Roof Penetration
10% Chrysotile 200 SF Cat II
Generator Building
Results Approx
Quantity
NESHAP
Category
12-166, 12-167 Roof Penetration
10% Chrysotile 100 SF Cat II
INTRODUCTION
TRC Environmental Corporation (TRC) was contracted by the United States International Boundary and Water Commission (IBWC) to conduct an asbestos survey at the San Ysidro Waste Water Treatment Plant Buildings located at 2225 Dairy mart Road, San Diego, California. The field activities portion of the asbestos survey was performed on February 14 and 15, 2014, by Mr.
Sam Seneviratne, California Certified Asbestos Consultant (CAC #93-0886) and Mr. Hector Gonzalez, California Certified Site Surveillance Technician (CSST # 06-4072) employed by TRC.
The asbestos survey findings found in this report will be used to effectively manage asbestos-containing materials (ACM) in the scope areas of the San Ysidro Water Treatment Plant building structures (the “Site”). The accumulated assessment information may be used in operations and maintenance plans for the facility designed to prevent accidental disturbance to ACM. TRC’s scope of the survey excluded any subsurface materials and/or structures.
BUILDING DESCRIPTION
The following provides a summary of the Buildings and appurtenant structures that were surveyed and buildings defined as the scope of work areas under the Contract with IBWC. The building structures are located on federal land, were considered non-public buildings, are secured by fencing/locked gates. A description of the building structures are as follows:
San Diego Field Office: This is a 4,320 square foot Modular Trailer with a reported construction date of 1995. It is constructed of wood and consists of a metal roof. The interior finishes consist of carpeting on the floors, vinyl floor coverings in the restrooms and kitchen, suspended ceiling panels and wood paneled walls.
Maintenance and Operations Building: The Maintenance Building is 4,860 square feet in size and the Operations Building is 3,848 square feet with a reported construction date of 2011. The interior finishes consist of rubberized floor covering, suspended ceiling panels, and gypsum board wall finishes. Roof coverings consist of built-up cap sheet roof coverings with gravel ballast.
Switchgear Building: This is a 2,639 square foot building constructed on concrete slab with metal framing and a built-up cap sheet roof with gravel ballast in 1996. The interior finishes consist of unfinished concrete floors and ceilings and wallboard wall finishes. Roof coverings consist of built-up cap sheet roof coverings with gravel ballast.
Truck Loading Building: This is a 5,992 square foot poured in place concrete building constructed in 1996. It is an all concrete building with a texture painted exterior
Head Works Grit & LLC East Building: This is a combined building that is 5,992 and 2,193 square feet in size. The building construction consists of poured in place concrete and was constructed in 1996. The interior finishes consist of unfinished concrete floors and non-slip textured floors textured exterior walls and wallboard wall finishes in the restrooms.
Administration Building: This building is 8,131 in size and is constructed with metal studs on a concrete slab and was constructed in 1996. The interior finishes consist of carpeted floor coverings, suspended ceiling panels, and gypsum board wall finishes. The exterior walls are finished with the Exterior Finish Insulation System (EFIS). Roof coverings consist of built-up cap sheet roof coverings with gravel ballast.
Dewatering Building: This building is 6924 square feet in size and consists of concrete construction. The interior finishes consist of unfinished concrete with a non-slip textured floors, textured exterior walls and built-up cap sheet roof coverings with gravel ballast.
Blower Building: This is a 7,072 square foot concrete building constructed in 2011. Finishes consist of textured exterior walls and built-up cap sheet roof coverings with gravel ballast.
Solids Thickening Building: This is a 460 square foot concrete building constructed in 2011.
Finishes consist of textured exterior walls and built-up cap sheet roof coverings with gravel ballast.
Generator Building: This is a 594 square foot concrete building constructed in 1997. Finishes consist of textured exterior walls and built-up cap sheet roof coverings with gravel ballast.
Secondary Sedimentation Building: This is a 1,040 square foot concrete building constructed in 2011. Finishes consist of textured exterior walls and built-up cap sheet roof coverings with gravel ballast.
Hollister St and Goat Canyon Pump Station Buildings: These building are 838 and 754 square feet in size and are constructed with concrete masonry units (CMU) in 2011. Finishes consist of textured exterior walls and built-up cap sheet roof coverings with gravel ballast.
Tijuana River Flood Control Gauging Station: This is a 64 square foot building and is constructed with concrete masonry units (CMU) and a concrete roof. The construction date is unknown.
SAMPLING AND ANALYTICAL PROCEDURES
Asbestos Sampling and Analytical Procedures
Representative bulk samples of suspect asbestos-containing building materials were randomly collected from the identified homogenous building material applications. Homogenous material determination was based on the following criteria:
Similar physical characteristics (same appearance, age, color and texture, etc.), Application (e.g. sprayed or trowel-on, assembly into a system, etc.), Material function (e.g. thermal insulation, floor tile, wallboard system, etc.).
Laboratory services were provided by TRC’s laboratory located in Windsor, Connecticut. TRC’s analytical laboratory is a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory (NVLAP code # 101424-0) and is in compliance with the National Environmental Laboratory Accreditation Conference (NELAC) requirements.
Bulk samples were analyzed by polarized light microscopy (PLM) utilizing the EPA’s Test Methods: Methods for the Determination of Asbestos in Bulk Building Materials (EPA 600/R- 93/116, July 1993) and the McCrone Research Institute’s The Asbestos Particle Atlas as method references.
Analysis by PLM was performed by visual observation of the bulk sample and by microscopic analysis using dispersion staining PLM methodology. The samples were analyzed for asbestiform minerals (Chrysotile, Amosite, Crocidolite, Anthophyllite, Actinolite, and Tremolite), fibrous non-asbestos constituents (mineral wool, cellulose, etc.) and non-fibrous constituents. Using a stereoscope, the microscopist visually estimates the relative amounts of each constituent by determining the estimated area of the asbestos compared with the area estimate of the total sample.
Analysis by PLM was performed by visual observation of the bulk sample and by microscopic analysis using dispersion staining PLM methodology. The samples were analyzed for asbestiform minerals (Chrysotile, Amosite, Crocidolite, Anthophyllite, Actinolite, and Tremolite), fibrous non-asbestos constituents (mineral wool, cellulose, etc.) and non-fibrous constituents. Using a stereoscope, the microscopist visually estimates the relative amounts of each constituent by determining the estimated area of the asbestos compared with the area estimate of the total sample.
INTERPRETATION OF ASBESTOS RESULTS
The Federal OSHA, the California Occupational Safety and Health Administration (Cal/OSHA), and National Emission Standards for Hazardous Air Pollutants (NESHAP) define an asbestos-containing material (ACM) as any material containing more than one percent (>1.0%) asbestos.
Both agencies have certain classifications for ACM types as well as requirements that apply when ACM is removed and disposed. Additionally, Cal/OSHA includes the term asbestos-containing construction material (ACCM); which is any manufactured construction material containing >0.1% asbestos. The ACCM designation has been established by Cal/OSHA as a criterion for the registration and certification of contractors and consultants respectively, who provide services that, involve such materials.
The lower limit of reliable detection for asbestos using the PLM analytical method is one percent (1.0%) by volume. Any sample indicating a concentration of <1.0% can be subjected to the more stringent Point Count Method of analysis to more precisely determine the actual asbestos content.
However, Cal/OSHA states that employers performing construction activities on materials containing any detectable asbestos must comply with all applicable provisions of Title 8, California Code of Regulations (CCR), Section 1529 (8 CCR 1529). Therefore, those materials which fall outside the NESHAP definition of an ACM are regulated by Cal/OSHA, and should be handled as ACCM by qualified personnel.
Per United States EPA NESHAP regulations, “friable” materials with PLM results of less than ten percent (<10%) asbestos must be assumed ACM unless it is further analyzed using the EPA Point Count Method to more precisely determine the actual asbestos content. If this material is found to contain less than 1% asbestos by point counting, then it may be disposed of as non-hazardous waste. However, if asbestos was detected above 0.1% concentration following the point count analysis, Cal/OSHA rules would still apply, and the contractor performing removal or demolition must comply with the worker protection, training, and medical surveillance portions of the asbestos standard. Note that the term “friable asbestos-containing material” means any ACM applied on ceilings, walls, structural members, piping, duct work, or any other part of a building which when dry may be crumbled, pulverized, or reduced to powder by hand pressure. The term includes non-friable ACM after such previously non-friable material becomes damaged to the extent that when dry it may be crumbled, pulverized, or reduced to powder by hand pressure.
FINDINGS
One hundred and seventy seven (177) suspect asbestos bulk samples were submitted to TRC Industrial Hygiene Laboratory, an accredited asbestos analytical laboratory, for analysis by PLM methodology. The laboratory analyzed one hundred and ninety-two (192) distinct sample layers as per the stop at first positive analytical criteria. The following listing identifies building materials that were found to contain detectable levels of asbestos by laboratory analysis. Asbestos was detected in some of the suspect asbestos containing bulk material samples analyzed by the laboratory or were assumed/presumed ACM:
ASBESTOS CONTAINING MATERIALS
Tijuana River Flood Control Project Gauging Station
Results Approx
Quantity
NESHAP
Category
16-88 Roof Penetration
20% Chrysotile <1 SF Cat II
Solids Thickening Building
Results Approx
Quantity
NESHAP
Category
12-168 Roof Penetration
10% Chrysotile 200 SF Cat II
Generator Building
Results Approx
Quantity
NESHAP
Category
12-166, 12-167 Roof Penetration
10% Chrysotile 100 SF Cat II
SAMPLED MATERIALS WHERE NO ASBESTOS WAS DETECTED
The complete listing of the suspect asbestos containing materials sampled and submitted to the laboratory can be found in Appendix B. The other suspect ACM bulk samples that were submitted to the laboratory were determined by laboratory analysis, not contain detectable amounts of asbestos.
CONCLUSIONS AND RECOMMENDATIONS
Results of bulk sample analysis confirmed that asbestos was identified in regulated concentrations within some of the building materials sampled. At the time of this survey, the ACM identified was found to be in conditions ranging from poor to good. If materials with similar physical characteristics to the identified ACM are encountered in other areas or buildings other than what is noted in this survey report, these materials must be considered to be asbestos containing unless an appropriate survey, sampling, and laboratory analysis of bulk samples obtained from these materials proves otherwise.
Persons performing demolition activities/work on Site should be aware that additional materials may be present in wall or ceiling cavities and voids and in areas not specifically identified in this report. Additionally the Contractor must be aware that suspect ACM which are either inaccessible or hidden in voids may exist and can be exposed during demolition activities. Care should be used when performing work that disturbs building materials or during subsurface work activities where piping or asbestos-contaminated soil may exist. Any suspect asbestos containing materials uncovered during maintenance, renovation, demolition, or excavation activities that are not addressed in this inspection report, or presumed asbestos containing materials (e.g. fire doors with asbestos laden cores), must be sampled by an accredited asbestos inspector prior to disturbance, or they must otherwise be assumed and treated as asbestos containing.
DISCLAIMER
The content presented in this report is based on data collected during the site inspection and survey, review of pertinent regulations, requirements, guidelines and commonly followed industry standards, and information provided (if any) by the property owner, their clients, agents, and representatives for the property described as IBWC San Ysidro Water Treatment Plant, San Diego, CA.
The work has been conducted in an objective and unbiased manner and in accordance with generally accepted professional practice for this type of work. TRC believes the data and analysis to be accurate and relevant, but cannot accept responsibility for the accuracy or completeness of available documentation or possible withholding of information of other parties. Structures or components thereof surveyed may contain hidden surfaces or materials requiring destructive access to inspect and/or sample. It is possible that additional materials could be discovered during destructive or demolition activities. In the event additional materials (not identified herein) are discovered during such activities, additional investigation and sampling may be necessary.
This asbestos and lead-based paint inspection report is designed to aid the Owner, its architect, construction manager, general contractor, and asbestos or LBP abatement contractor in locating ACM and/or LBP on this Site. This report is not intended for, and may not be utilized as, a bidding document or as an abatement project specification document.
CERTIFICATION AND SIGNATORY PAGE
TRC hereby certifies that the services conducted and described in this document and the findings resulting from those services reported herein have been provided in a manner consistent with the current standards of the profession and. to the best of our knowledge, comply with all federal, state, and local statutes, regulations, and ordinances.
Surveyed and Reported by:
TRC ENVRIONMENTAL CORPORATION
Sam Seneviratne, CAC, CDPH I/A Project Manager Cal-OSHA CAC #93-0886
CA DPH # 9658
Reviewed by:
Douglas W. Coburn, CAC, CDPH I/A Sr. Project Manager Cal-OSHA CAC # 92-0223
CA DPH # 14092
TABLE 1.0
Homogeneous Materials Summary
TABLES – HOMOGENOUS MATERIALS SUMMARY
International Boundary & Water Commission – San Yisidro, CA Page 1
Building Name Sample Numbers Material Material Location(s) Analytical Results Approx
Quantity
NESHAP
Category
Administration Building
8-1 through 8-3 2’ x 2’ Suspended Ceiling
Panel Main Entry Lobby, Hallway Corridor
ND 3,600 SF NA
Administration Building
8-4 through 8-6 Beige Wall Paper Main Entry Lobby, Hallway Corridor
ND 12,000 SF NA
Administration Building
8-7 through 8-9 Wallboard Main Entry Lobby, Hallway Corridor
ND 12,000 SF NA
Administration Building
8-10 through 8-12 Joint Compound Main Entry Lobby, Hallway Corridor
ND 12,000 SF NA
Administration Building
8-13 through 8-15 4” Beige Cove Base and
Cream Glue Main Entry Lobby, Hallway Corridor
ND 400 LF NA
Administration Building
8-16 through 8-18 Green with Wood Chip
Paper Vinyl Sheet Flooring and Brown Glue
Main Entry Lobby, Hallway Corridor
ND 1,800 SF NA
Administration Building
8-19 Concrete Main Entry Lobby, Hallway Corridor
ND 3,600 SF NA
Administration Building
8-22 through 8-24 Carpet Mastic Main Entry Lobby, Conference Room
ND 1,800 SF NA
Administration Building
8-25 through 8-27 Cream Ceramic Tile Grout Restrooms Walls and
Floors
ND 10,000 SF NA
Administration Building
8-28 through 8-30 Exterior Finish Insulation
System (EFIS) Exterior Walls ND 5,000 SF NA
Administration Building
8-31 through 8-33 Duct Sealant Mastic Roof HVAC Ducting ND 50 SF NA
Administration Building
8-34 through 8-36 Black Penetration Mastic Roof Penetrations ND 50 SF NA
Administration Building
8-37 through 8-39 Built up Cap Sheet (Top
Layer) Roof ND 6,000 SF NA
Administration Building
8-40 through 8-42 Built up Cap Sheet (2nd
Layer) Roof ND 6,000 SF NA
Administration Building
8-43 through 8-45 Roof Insulation Roof ND 6,000 SF NA
International Boundary & Water Commission – San Yisidro, CA Page 2
Quantity
NESHAP
Category
Sludge Dewatering Building
9-46 through 9-48 Non-Slip Surface/Texture Top of Concrete Floor ND 10,000 SF NA
Sludge Dewatering Building
9-49 Concrete Floor ND 20,000 SF NA
Sludge Dewatering Building
9-52 through 9-54 Caulk between Concrete
Floor Panels Floor ND 2,000 LF NA
Sludge Dewatering Building
9-55 through 9-57 Textured Paint Exterior Concrete Walls ND 8,000 SF NA
Sludge Dewatering Building
9-58 through 9-60 Duct Sealant Mastic Lower and Upper Roofs ND 16 SF NA
Sludge Dewatering Building
9-61 through 9-63 Penetration Mastic Lower and Upper Roofs ND 40 SF NA
Sludge Dewatering Building
9-64 through 9-66 Roof Cap Sheet Lower and Upper Roofs ND 7,000 SF NA
Sludge Dewatering
9-67 through 9-69 Roof Insulation Lower and Upper Roofs ND 7,000 SF NA
Quantity
NESHAP
Category
Truck Loading Building
5-70 through 5-72 Textured Paint Exterior Walls ND 10,000 SF NA
Truck Loading
5-73 Concrete Throughout ND 8,000 SF NA
International Boundary & Water Commission – San Yisidro, CA Page 3
Building Name Sample Numbers Material Material Location(s) Analytical Results Approx
Quantity
NESHAP
Category
Head Works Building (Grit and
LLC)
6/7-76 through 6/7-78
Non-Slip Textured Floor Coating
Throughout ND 3,000 SF NA
Head Works Building (Grit and
LLC)
6/7-79 Concrete Throughout ND 20,000 SF NA
Head Works Building (Grit and
LLC)
6/7-82 through 6/7-84
Textured Wall Paint Throughout ND 6,000 SF NA
Head Works Building (Grit and
LLC)
6/7-112 through 6/7-114
Wallboard Restroom Partition Walls ND 160 SF NA
Head Works Building (Grit and
LLC)
6/7-115 through 6/7-117
Joint Compound Restroom Partition Walls ND 160 SF NA
Quantity
NESHAP
Category
Tijuana River Floor Control
Gaging Station
16-85 through 16-87
Concrete CMU and Grout Walls ND 640 SF NA
Tijuana River Floor Control
Gaging Station 16-88 Penetration Mastic Penetrations ND <1 SF NA
International Boundary & Water Commission – San Yisidro, CA Page 4
Building Name Sample Numbers Material Material Location(s) Analytical Results Approx
Quantity
NESHAP
Category
Goat Canyon Pump Station
15-91 through 15-93
Sealant Caulk on Concrete Floor, Wall and
Penetrations
ND 100 LF NA
Goat Canyon Pump Station
15-94 through 15-95
Roof Cap Sheet with Gravel Roof ND 800 SF NA
Goat Canyon Pump Station
15-97 through 15-98
Mastic at Penetrations Penetrations ND 60 SF NA
Goat Canyon Pump Station
15-100 through 15-101
Textured Exterior Wall Paint
Exterior Walls ND 1,800 SF NA
Quantity
NESHAP
Category
Hollister Street Pump Station
14-103 Textured Exterior Wall
Paint Exterior Walls ND 1,800 SF NA
Hollister Street Pump Station
14-106 Roof Cap Sheet with Gravel Roof ND 800 SF NA
Hollister Street Pump Station
14-109 Mastic at Penetrations Penetrations ND 60 SF NA
Quantity
NESHAP
Category
Operations and Maintenance
Building
2/3-118 through 2/3-120
2’ x 2’ Drop Ceiling Panel Throughout ND 6,000 SF NA
Operations and Maintenance
Building
2/3-121 through 2/3-122
Wallboard Throughout ND 13,000 SF NA
Operations and Maintenance
Building
2/3-124 through 2/3-125
Joint Compound Throughout ND 13,000 SF NA
International Boundary & Water Commission – San Yisidro, CA Page 5
Building Name Sample Numbers Material Material Location(s) Analytical Results Approx
Quantity
NESHAP
Category
Operations and Maintenance
Building
2/3-127 through 2/3-129
5” Cream Cove Base and Glue
Throughout ND 800 LF NA
Operations and Maintenance
Building
2/3-130 through 2/3-132
Rubber Flooring and Clear Glue
Throughout ND 6,000 SF NA
Operations and Maintenance
Building
2/3-133 through 2/3-135
Roof Cap Sheet With Gravel
Roof ND 6,000 SF NA
Operations and Maintenance
Building
2/3-136 through 2/3-138
Mastic at Penetrations Roof Penetrations ND 100 SF NA
Operations and Maintenance
Building 2/3-139 Wallboard Throughout ND 2,000 SF NA
Operations and Maintenance
2/3-142 Joint Compound Throughout ND 2,000 SF NA
Quantity
NESHAP
Category
Main Switchgear Building
4-145 through 4-
Wallboard Throughout ND 3,000 SF NA
Main Switchgear Building
4-148 through 4-
Joint Compound Throughout ND 3,000 SF NA
Main Switchgear Building
4-151 through 4-
Roof Cap Sheet with Gravel Roof ND 2,400 SF NA
Main Switchgear Building
4-154 through 4-
Mastic at Penetrations Penetrations ND 50 SF NA
International Boundary & Water Commission – San Yisidro, CA Page 6
Building Name Sample Numbers Material Material Location(s) Analytical Results Approx
Quantity
NESHAP
Category
Generator Building (Building 11 & 12)
12-157 through 11-159
Exterior Concrete Texture Exterior Walls ND 2,000 SF NA
Generator Building (Building 11 & 12)
12-160 through 12-162
Caulk between Concrete Floor Panels
Building 12 – Floor ND 200 LF NA
Generator Building (Building 11 & 12)
12-163 through 11-165
Roof Cap Sheet Roofs ND 1,000 SF NA
Generator Building (Building 11 & 12)
12-166 through 11-168
Penetration Mastic Roof Penetrations 10% Chrysotile 120 SF Cat II
Generator Building (Building 11 & 12)
12-169 through 12-171
Duct Sealant Mastic Building 12 – HVAC
Ducting
ND 200 SF NA
Quantity
NESHAP
Category
Building 10 10-172 Roof Cap with Gravel Roofs ND 7,350 SF NA
Building 10 10-175 through
10-176 Penetration Mastic/Sealant Penetrations ND 100 SF NA
Building 10 & 13 10-178 through
13-180 Exterior Concrete Texture Exterior Walls ND 42,000 SF NA
Building 13 13-181 through
13-183 Duct Sealant Mastic Roof ND 40 SF NA
Building 13 13-184 through
13-185 Roof Penetration Sealant Roof Penetrations ND 40 SF NA
Building 13 13-187 through
13-188 Roof Cap Sheet with Foam
Insulation Roof ND 1,200 SF NA
International Boundary & Water Commission – San Yisidro, CA Page 7
Building Name Sample Numbers Material Material Location(s) Analytical Results Approx
Quantity
NESHAP
Category
Building 1 1-190 through
1-191 2’ x 4’ Suspended Ceiling
Panel Throughout ND 3,564 SF NA
Building 1 1-193 through
1-195 Carpet Glue
Throughout (excluding Restrooms and Kitchen)
ND 3,200 SF NA
Building 1 1-196 through
1-198 Cream Vinyl Sheet Flooring Kitchen and Restrooms ND 170 SF NA
Building 1 1-199 through
1-201 6” Brown Cove Base and
White Glue Kitchen and Restrooms ND 110 LF NA
Building 1 1-202 through
1-204 6” Clay Tile Grout Front Patio ND 600 SF NA
Table Key
ND – None Detected NA – Not Applicable SF – Square Feet LF – Linear Feet Cu Ft – Cubic Feet Cat I – Category I Non-Friable Asbestos Containing Material Cat II - Category II Non-Friable Asbestos Containing Material RACM – Regulated Asbestos Containing Material (Friable) ACM – Asbestos Containing Material; Contains greater than 1% asbestos by weight NESHAP – National Emissions Standards for Hazardous Air Pollutants (EPA asbestos regulation)
Appendix A
Bulk Asbestos Sample Laboratory Report
Industrial Hygiene Laboratory 21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Lab Log #: 0043602
2225 Dairy Mart Road, San Ysidro, CA
CLIENT: International Boundary & Water Commission
Site:
Date Analyzed:
Date Received:
02/19/2014
02/18/2014
Project #: 209058.0009.0000
BULK ASBESTOS ANALYSIS REPORT
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered cellulose mineral wool
None- -8-1 ND40% 40%
Yes NoWhite/Grey cellulose mineral wool
None- -8-2 ND40% 40%
Yes NoWhite/Grey synthetic fiber None- -8-3 ND80%Yes NoBeige synthetic fiber None- -8-4 ND80%Yes NoBeige synthetic fiber None- -8-5 ND80%Yes NoBeige synthetic fiber None- -8-6 ND80%Yes NoBeige
- - - None- -8-7 NDYes NoWhite
- - - None- -8-8 NDYes NoWhite
- - - None- -8-9 NDYes NoWhite
- - - None- -8-10 NDYes NoWhite
- - - None- -8-11 NDYes NoWhite
- - - None- -8-12 NDYes NoWhite
- - - None18-13 NDNo YesCream (glue)
- - - None28-13 NDNo YesBeige (cove base)
- - - None18-14 NDNo YesCream (glue)
- - - None28-14 NDNo YesBeige (cove base)
- - - None18-15 NDNo YesCream (glue)
- - - None28-15 NDNo YesBeige (cove base)
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
MA #AA000052
HI #L-09-004
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered
- - - None18-16 NDNo YesBrown (glue)
- - - None28-16 NDNo YesGreen (vinyl floor)
- - - None18-17 NDNo YesBrown (glue)
- - - None28-17 NDNo YesGreen (vinyl floor)
- - - None18-18 NDNo YesBrown (glue)
- - - None28-18 NDNo YesGreen (vinyl floor)
- - - None- -8-19 NDYes NoGrey
- - - None- -8-22 NDYes NoYellow
- - - None- -8-23 NDYes NoYellow
- - - None- -8-24 NDYes NoYellow
- - - None- -8-25 NDYes NoGrey
- - - None- -8-26 NDYes NoGrey
- - - None- -8-27 NDYes NoGrey
- - - None- -8-28 NDYes NoGrey
- - - None- -8-29 NDYes NoGrey
- - - None- -8-30 NDYes NoGrey
- - - None- -8-31 NDYes NoGrey
- - - None- -8-32 NDYes NoGrey
- - - None- -8-33 NDYes NoGrey
- - - None- -8-34 NDYes NoBlack
- - - None- -8-35 NDYes NoBlack
- - - None- -8-36 NDYes NoBlack synthetic fiber None- -8-37 ND10%Yes NoBlack synthetic fiber None- -8-38 ND10%Yes NoBlack
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered synthetic fiber None- -8-39 ND10%Yes NoBlack fibrous glass None- -8-40 ND10%Yes NoBlack fibrous glass None- -8-41 ND10%Yes NoBlack fibrous glass None- -8-42 ND10%Yes NoBlack cellulose None- -8-43 ND80%Yes NoBrown cellulose None- -8-44 ND80%Yes NoBrown cellulose None- -8-45 ND80%Yes NoBrown
- - - None- -9-46 NDYes NoBeige
- - - None- -9-47 NDYes NoBeige
- - - None- -9-48 NDYes NoBeige
- - - None- -9-49 NDYes NoGrey
- - - None- -9-52 NDYes NoGrey
- - - None- -9-53 NDYes NoGrey
- - - None- -9-54 NDYes NoGrey
- - - None- -9-55 NDYes NoBeige
- - - None- -9-56 NDYes NoBeige
- - - None- -9-57 NDYes NoBeige synthetic fiber None- -9-58 ND10%Yes NoGrey synthetic fiber None- -9-59 ND10%Yes NoGrey synthetic fiber None- -9-60 ND10%Yes NoGrey cellulose None- -9-61 ND20%Yes NoBlack cellulose None- -9-62 ND20%Yes NoBlack cellulose None- -9-63 ND20%Yes NoBlack fibrous glass None- -9-64 ND10%Yes NoBlack
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered fibrous glass None- -9-65 ND10%Yes NoBlack fibrous glass None- -9-66 ND10%Yes NoBlack cellulose None- -9-67 ND80%Yes NoBrown cellulose None- -9-68 ND80%Yes NoBrown cellulose None- -9-69 ND80%Yes NoBrown
- - - None- -5-70 NDYes NoBeige
- - - None- -5-71 NDYes NoBeige
- - - None- -5-72 NDYes NoBeige
- - - None- -5-73 NDYes NoGrey
- - - None- -6/7-76 NDYes NoBlack
- - - None- -6/7-77 NDYes NoBlack
- - - None- -6/7-78 NDYes NoBlack
- - - None- -6/7-79 NDYes NoGrey
- - - None- -6/7-82 NDYes NoBeige
- - - None- -6/7-83 NDYes NoBeige
- - - None- -6/7-84 NDYes NoBeige
- - - None- -6/7-112 NDYes NoWhite
- - - None- -6/7-113 NDYes NoWhite
- - - None- -6/7-114 NDYes NoWhite
- - - None- -6/7-115 NDYes NoWhite
- - - None- -6/7-116 NDYes NoWhite
- - - None- -6/7-117 NDYes NoWhite
- - - None- -16-85 NDYes NoLight Grey
- - - None- -16-86 NDYes NoGrey
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered
- - - None- -16-87 NDYes NoGrey
- - - Chrysotile- -16-88 20%Yes NoBlack synthetic fiber None- -15-91 ND10%Yes NoGrey synthetic fiber None- -15-92 ND10%Yes NoGrey synthetic fiber None- -15-93 ND10%Yes NoGrey fibrous glass None- -15-94 ND10%Yes NoBlack fibrous glass None- -15-95 ND10%Yes NoBlack cellulose None- -15-97 ND10%Yes NoBlack cellulose None- -15-98 ND10%Yes NoBlack
- - - None- -15-100 NDYes NoBeige
- - - None- -15-101 NDYes NoBeige
- - - None- -14-103 NDYes NoBeige cellulose None- -14-106 ND30%Yes NoBlack cellulose None- -14-109 ND10%Yes NoBlack cellulose mineral wool
None- -2/3-118 ND40% 40%
Yes NoWhite/Grey cellulose mineral wool
None- -2/3-119 ND40% 40%
Yes NoWhite/Grey cellulose mineral wool
None- -2/3-120 ND40% 40%
Yes NoWhite/Grey
- - - None- -2/3-121 NDYes NoWhite
- - - None- -2/3-122 NDYes NoWhite
- - - None- -2/3-124 NDYes NoWhite
- - - None- -2/3-125 NDYes NoWhite
- - - None12/3-127 NDNo YesCream (glue)
- - - None22/3-127 NDNo YesCream (cove base)
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered
- - - None12/3-128 NDNo YesCream (glue)
- - - None22/3-128 NDNo YesCream (cove base)
- - - None12/3-129 NDNo YesCream (glue)
- - - None22/3-129 NDNo YesCream (cove base)
- - - None12/3-130 NDNo YesColorless (glue)
- - - None22/3-130 NDNo YesBlue (flooring)
- - - None12/3-131 NDNo YesColorless (glue)
- - - None22/3-131 NDNo YesBlue (flooring)
- - - None12/3-132 NDNo YesColorless (glue)
- - - None22/3-132 NDNo YesBlue (flooring) cellulose None- -2/3-133 ND10%Yes NoBlack cellulose None- -2/3-134 ND10%Yes NoBlack cellulose None- -2/3-135 ND10%Yes NoBlack cellulose None- -2/3-136 ND30%Yes NoBlack cellulose None- -2/3-137 ND30%Yes NoBlack cellulose None- -2/3-138 ND30%Yes NoBlack
- - - None- -2/3-139 NDYes NoWhite
- - - None- -2/3-142 NDYes NoWhite
- - - None- -4-145 NDYes NoWhite
- - - None- -4-146 NDYes NoWhite
- - - None- -4-147 NDYes NoWhite
- - - None- -4-148 NDYes NoWhite
- - - None- -4-149 NDYes NoWhite
- - - None- -4-150 NDYes NoWhite
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered synthetic fiber None- -4-151 ND10%Yes NoBlack synthetic fiber None- -4-152 ND10%Yes NoBlack synthetic fiber None- -4-153 ND10%Yes NoBlack cellulose None- -4-154 ND20%Yes NoBlack cellulose None- -4-155 ND20%Yes NoBlack cellulose None- -4-156 ND20%Yes NoBlack
- - - None- -12-157 NDYes NoBeige
- - - None- -12-158 NDYes NoBeige
- - - None- -11-159 NDYes NoBeige
- - - None- -12-160 NDYes NoGrey
- - - None- -12-161 NDYes NoGrey
- - - None- -12-162 NDYes NoGrey cellulose fibrous glass
None- -12-163 ND10% 10%
Yes NoBlack cellulose fibrous glass
None- -12-164 ND10% 10%
Yes NoBlack cellulose fibrous glass
None- -11-165 ND10% 10%
Yes NoBlack
- - - Chrysotile- -12-166 10%Yes NoBlack
- - - -- -12-167 NA/PS- - - -- -
- - - -- -11-168 NA/PS- - - -- -
synthetic fiber None- -12-169 ND2%Yes NoBlack synthetic fiber None- -12-170 ND2%Yes NoBlack synthetic fiber None- -12-171 ND2%Yes NoBlack fibrous glass None- -10-172 ND10%Yes NoBlack
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered cellulose synthetic fiber
None- -10-175 ND10% 5%
Yes NoBlack cellulose synthetic fiber
None- -10-176 ND10% 5%
Yes NoBlack
- - - None- -10-178 NDYes NoBeige
- - - None- -10-179 NDYes NoBeige
- - - None- -13-180 NDYes NoBeige
- - - None- -13-181 NDYes NoGrey
- - - None- -13-182 NDYes NoGrey
- - - None- -13-183 NDYes NoGrey cellulose None- -13-184 ND30%Yes NoBlack fibrous glass None- -13-187 ND10%Yes NoBlack fibrous glass None- -13-188 ND10%Yes NoBlack cellulose mineral wool
None- -1-190 ND40% 40%
Yes NoWhite/Grey cellulose mineral wool
None- -1-191 ND40% 40%
Yes NoWhite/Grey cellulose mineral wool
None- -1-192 ND40% 40%
Yes NoWhite/Grey
- - - None- -1-193 NDYes NoYellow
- - - None- -1-194 NDYes NoYellow
- - - None- -1-195 NDYes NoYellow cellulose None- -1-196 ND30%Yes NoGrey cellulose None- -1-197 ND30%Yes NoGrey cellulose None- -1-198 ND30%Yes NoGrey
- - - None11-199 NDNo YesWhite (glue)
- - - None21-199 NDNo YesBrown (cove base)
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
21 Griffin Road North Windsor, CT 06095
(860) 298-6308
43602.IBWC.doc
Layer No. Asbestos Type
Other Matrix MaterialsSample No. Homogenous
Asbestos
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
Color Multi-
Layered
- - - None11-200 NDNo YesWhite (glue)
- - - None21-200 NDNo YesBrown (cove base)
- - - None11-201 NDNo YesWhite (glue)
- - - None21-201 NDNo YesBrown (cove base)
- - - None- -1-202 NDYes NoGrey
- - - None- -1-203 NDYes NoGrey
- - - None- -1-204 NDYes NoGrey
Reporting limit- asbestos present at 1%
Trace - asbestos was observed at level of less than 1% NA/PS - Not Analyzed / Positive Stop
The Laboratory at TRC follows the EPA's Interim Method for the Determination of Asbestos in Bulk Insulation (1982), and the EPA recommended Method for the Determination of Asbestos in Bulk Building Materials (EPA/600/R-93/116), July 1993, R.L. Perkins and B.W. Harvey which utilizes polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 18/A01, effective through June 30, 2014.
TRC is an American Industrial Hygiene Association (AIHA) accredited lab for PLM effective through October 1, 2014. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and the QC data related to the samples is available upon written request from the client.
This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested.
ND - asbestos was not detected
Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, negative results must be confirmed by quantitative transmission electron microscopy.
Analyzed by: Reviewed by: Date Issued
02/21/2014Kathleen Williamson, Laboratory Manager Amanda Parkins, Approved Signatory
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0
RI #AAL-007C3 TX #300354
AIHA #100122
VT #AL014538
CT #PH-0426
VA #3333 000283
NY #10980
NJ #CT004
WV# LT000356
CA #10275CA
ME LA-0075, LB-0071
AZ #A20944
Appendix B
Sample Location Figures
Appendix C
Select Photographs
Photographs USIBWC San Ysidro, CA
TRC Job No. Photographs Taken By: Client: Site Name & Address:
209058 Phase 9 Sam Seneviratne USIBWC.
San Ysidro Waste Water treatment Plant
2225 Dairy Mart Rd. San Ysidro, CA
1. Main Admin Building - Metal Stud Wall on Concrete Slab
2. Truck Loading Building - Concrete
3. Head Works Building - Concrete 4. Head Works Building - Interior
5. Tijuana Flood Gauging Station 6. Tijuana Flood Gauging Station - Penetration Mastic
7. Sludge De-watering Building 8. Administration Building Roof (typical)
9. Administration Building - HVAC ducting (typical)
10. Goat Canyon and Hollister St.
Pump Station
11. Goat Canyon and Hollister St.
Pump Station - Sealant Mastic at Penetrations
12. Goat Canyon and Hollister St.
Pump Station - Sealant Mastic at Concrete Tilt-up Walls
13. Operations and Maintenance Building (O&M Bldg.)
14. O&M Building - Rubber flooring and base coves in hallways
15. O&M Building - Roof cap sheet coverings with gravel
16. Generator building
17. San Diego Field Office 18. San Diego Field Office - Vinyl flooring and base coves in restrooms and kitchen
Appendix D
Inspector Certifications
| USIBWC San Ysidro Asbestos Survey Reportf.pdf |
| IBWC_San Yisidro, CA_Table_Summary of Homogenous Materials Results |
| header Appendix A |
| Atch A results 0043602-IBWC San Yisidro ALL |
| Header B |
| San Ysidro Drawings |
| Header C |
| Photo pages |
| Header d |
| Sam's CA ACM & Lead Certs Exp 2015 |
File details come from the government source that posted it. Updated .