1572053_P1394B_dwg 12of14.pdf
PDF 3 MB Posted
- Attached to
- P1394 PHASE B VEHICLE MAINTENANCE AND STORAGE, MARINE CORPS BASE, CAMP LEJEUNE, NORTH CAROLINA
- Solicitation number
- N4008522R2639
About this file
This is a solicitation for a construction project at Marine Corps Base Camp Lejeune in North Carolina. The project constructs two buildings: a 18,000 square foot Boat Maintenance and Storage Facility and a 20,000 square foot Large Vehicle Maintenance Storage Building. The Boat Maintenance Facility includes spaces for rubber repair, engine repair, parts storage, life safety storage and boat storage. The Large Vehicle Storage Building includes five single bay storage areas and one multi-bay storage area, each served by an office. It also includes a covered canopy structure for three forklifts. Both buildings will have mechanical, electrical, plumbing and information systems. Site work includes utility systems, traffic control, parking, communications infrastructure and stormwater management. The solicitation is for the Department of the Navy Naval Facilities Engineering Command.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND
FIRE DAMPER
VOLUME DAMPER
CEILING RETURN, EXHAUST OR TRANSFER REGISTER OR GRILLE
CEILING SUPPLY DIFFUSER
MITERED ELBOW WITH TURNING VANES
RETURN DUCT TURNING UP
RETURN DUCT TURNING DOWN
EXHAUST DUCT TURNING UP
EXHAUST DUCT TURNING DOWN
SUPPLY DUCT TURNING UP (ROUND OR RECTANGULAR)
SUPPLY DUCT TURNING DOWN (ROUND OR RECTANGULAR)
10"x10" SQUARE OR RECTANGULAR DUCTWORK
PIPE TURNING UP
PIPE TURNING DOWN
THERMOSTAT
DUCT SMOKE DETECTOR
CD
(CFM)
DIFFUSER GRILLE, REGISTER
WITH CFM INDICATED
GENERAL
DUCTWORK
MOTORIZED CONTROL DAMPER
INDICATES ROUND DUCTWORK
FLEXIBLE CONNECTION
AIR FLOW
ACCESS DOORAD
ABOVE FINISHED FLOORAFF
ALUMINUMALUM
ARCHITECTURALARCH
DIAMETERDIA
DRAWINGDWG
MISCELLANEOUSMISC
TYPICALTYP
UNLESS OTHERWISE
NOTED
UON
GALVANIZEDGALV
AUTOMATIC AIR VENT
VALVES AND ACCESSORIES
AUTOMATIC FLOW CONTROL VALVE
CAPPED PIPE
CHECK VALVE
FLEXIBLE CONNECTION
FLOW METER
MANUAL AIR VENT
PRESSURE/TEMPERATURE TEST PLUGPT
PRESSURE RELIEF VALVE
PRESSURE GAUGE WITH GAUGE COCK
STRAINER
STRAINER W/BLOW DOWN VALVE
TWO WAY CONTROL VALVE
THERMOMETER
TOP CONNECTION
UNION
VACUUM BREAKER
CONTROLS
ANALOG INPUT (TO PANEL)
ANALOG OUTPUT (OUT OF PANEL)
DIGITAL INPUT (TO PANEL)
DIGITAL OUTPUT (OUT OF PANEL)
TWO WAY CONTROL VALVE
COMMON
CONTROL WIRING (SIGNAL PATH)
DIFFERENTIAL PRESSURE SENSOR
VARIABLE SPEED DRIVE
AI
DI
DO
C
FREEZESTAT
HIGH LIMIT TEMPERATURE SENSOR
HUMIDISTAT
MOTOR
MOTORIZED CONTROL DAMPER
NORMALLY CLOSEDNC
NORMALLY OPENEDNO
SENSOR
PRESSURE SENSOR
SWITCH
TIME CLOCK
CSR CURRENT SENSING RELAY
NORMALLY OPEN CONTROLS
NORMALLY CLOSED CONTROLS
HWS
HWR
RS
RL
D
HOT WATER SUPPLY
HOT WATER RETURN
REFRIGERANT LIQUID
REFRIGERANT SUCTION
CONDENSATE DRAIN LINE
PIPING
FLEXIBLE DUCT
M
M
M
AO
S
TC
DP
HL
H
S
T
SUPPLY DUCT TURNING UP (OVAL)
SUPPLY DUCT TURNING DOWN (OVAL)
10"/10" OVAL DUCTWORK
# CONSTRUCTION NOTE IDENTIFICATION
INDICATES NEW ITEM
ROOM NUMBER IDENTIFICATIONXXX
Ø
MANUAL VALVE
VFD
SPACE TEMPERATURE SENSORT
SPACE HUMIDITY SENSORH
SPEED CONTROLLERSC
ENERGY RECOVERY VENTILATORERV
EXHAUST FANEF
HEAT PUMPHP
OUTSIDE AIROA
RETURN AIRRA
UNIT HEATERUH
VARIABLE AIR VOLUMEVAV
SUPPLY AIRSA
FZ
P
SMOKE DETECTORSD
HUMIDITY SENSORH
AFMS AIRFLOW MEASURING STATION
SP STATIC PRESSURE SENSOR
T TEMPERATURE SENSOR
ELECTRIC WALL HEATEREWH
RETURN GRILLERG
EXHAUST GRILLEEG
TRANSFER GRILLETG
CEILING DIFFUSERCD
SUPPLY REGISTERSR
HEATING WATER PUMPHWP
SD
EXPANSION TANKET
AIR DIRT SEPARATORADS
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
M-001
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
M E
C H
A N
IC
A
L
LE
G E
N D
DAC
12827120
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross Typewritten Text
DSN
(1800 CFM)(60 MIN___
HR)(1 LB air /12.28 FT 3 )[0.010273-0.0001026(LB water /LB air )] = 89LB__
HR
HUMIDIFIER LOAD CALCULATION
ROOM FLOOR AREA: 1105 FT 2
ROOM HEIGHT: 8 FT
ROOM VOLUME: 8840 FT 3
SUPPLY AIRFLOW RATE: 1500 CFM
AIR CHANGES PER HOUR: (1500 CFM/60 MIN___
HR)/8840 FT 3 = 10AC__
HR
RUBBER REPAIR ROOM C116
AIR CHANGE RATE CALCULATION
(30 CFM______
PERSON )(30 PEOPLE/1000 FT 2)(1105 FT 2) = 944 CFM
VENTILATION RATE CALCULATION
REQUIRED: 994 CFM
SUPPLIED: 1500 CFM
C8C7C6C5C4C3C2C1
CA
CF
FCU-2C
FCU-4C
EF-1C
EF-2C
UH-2C
UH-2C
UH-1C
ACCU-1C
CUF-2C
CU-1
AC-1
CUF-4C
BOAT
MAINTENANCE
C101
RUBBER
REPAIR
C116
COMM
C115
ELEC
C114
LIFE
SAFETY
STORAGE
C109
SIPR CAFE
C112
OFFICE
C111
ENGINE
STORAGE
C103
HWR
HWS
H W
R H
W S
SA FROM
FCU-1C
RA TO
FCU-1C
SPRINK
C113
C1
MH101C
FABRIC DUCTWORK
1,166 CFM (A)
SUSPEND AIR
HANDLER 9'-6"
A.F.F.
CD-1
190 CD-1
RG-1
RG-1
8"ø
6"x6"
6"x6"
12"x10"
12"x10"
SA TO
FCU-3C
16"ø
2"2"
1"1"
1"1"
2"2" 1 1/2"1 1/2"
1 1/2"1 1/2"
1 1/4"1 1/4"
1 1/2"1 1/2" 2"2" 2"2"
1 1/4"1 1/4" 1 1/4"1 1/4"
S E
E M
H
2C F
O R
C O
N T
1 1/4"1 1/4"
1 1/4"1 1/4"
1"1" 1"1"
12"ø 16"x14"
R L/
R S
RL/RS TO
CUF-2C
R L/
R S
D
3/4"3/4"
D
D
1"1"
1"1"
1 1/4" D DN TO
DRAIN, SEE PLMB.
RD-1
RD-1
EG-2
D
1 1/4" D UP TO
MECHANICAL
PLATFORM
RL/RS UP TO
MECHANICAL
PLATFORM
R L/
R S
H-1
ACHP-1
HP-1
2"2"
1"1"SUSPEND UNIT
HEATER 9'-0"
AFF, TYP.
CU-1
AC-1
D
3/4"3/4"
ROUTE PIPES TIGHT
TO STRUCTURE,
PROVIDE MANUAL AIR
VENT AT HIGH POINT
26"x14"
17'-6" AFF
17'-6" AFF
SUSPEND UNIT
HEATER 9'-0"
AFF, TYP.
SUSPEND UNIT
HEATER 9'-0"
AFF, TYP.
T
T
T T
T
T
MECHANICAL
PLATFORM
10' - 1 1/4"
C7C6C5
AHU-1C
16"x14"
16"x16"
8"x32"
RD-1
EG-2
RD-1
7501 1/4" D DN TO DRAIN RL/RS TO ACCU-1C
16"x34"
14"ø
10"x32"
6" TH. EQUIP. PAD
1. MECHANICAL CONTRACTOR SHALL CLOSELY COORDINATE THE INSTALLATION
OF THE MECHANICAL SYSTEM WITH ALL DISCIPLINE CONTRACTORS.
2. ALL MECHANICAL EQUIPMENT AND INSTALLATION SHALL YIELD COMPLETE AND
OPERATIONAL SYSTEMS THAT CONFORM TO THE REQUIREMENTS OF THE
CONTRACT PLANS, SPECIFICATIONS, AND ALL APPLICABLE CODE AND UFC
REQUIREMENTS.
3. LOCATE ALL EQUIPMENT TO ALLOW FOR FULL ACCESS FOR MAINTENANCE.
4. ANY FRESH AIR INTAKES SHALL BE LOCATED A MINIMUM OF 10'-0" ABOVE GRADE
PER ATFP REQUIEMENTS.
5. EXPOSED DUCTWORK IS DOUBLE-WALL SPIRAL W/ PERFORATED INNER LINER
AND MYLAR COATING OVER LINER, UNLESS OTHERWISE NOTED ON PLANS.
6. INSULATE DUCTWORK AND PIPING THROUGH WALL PENETRATIONS.
C7C6C5
CA
C1
MH101C
AHU-1C
EA LOUVER, SEE
ARCH. FOR SIZE &
LOCATION
OA INTAKE LOUVER, SEE
ARCH. FOR SIZE & LOCATION
1 1/4"1 1/4"
1 1/4"1 1/4" 1"1"
R L/
R S
1 1/4" D DN
"x
8"
14"ø 14"ø
"x
14"x16"
34"x16" DN TO E.A. GRILLE
TO HWS/R MAINS
RL/RS DN TO ACCU-1C
22"x10"
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
MH101C
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
R R
F
LO
O R
P
LA
N
A R
E A
A
DAC
12827121
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
SCALE: 1/8" = 1'-0"
RR456 FLOOR PLAN - AREA A
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
AREA A AREA B
SCALE: 1/4" = 1'-0"
C1
SECTION AT AHU-C1
SCALE: 1/8" = 1'-0"
RR456 FLOOR PLAN - MECHANICAL PLATFORM
1 GRADE MOUNTED HEAT PUMP OR CONDENSING UNIT. INSTALL AND
SECURE UNIT TO CONCRETE PAD. ROUTE REFRIGERANT PIPING TO
AFFILIATED INDOOR AIR HANDLING UNIT.
2 CONDENSATE PIPE TO SLASH BLOCK ON GRADE.
3 AIR DISTRIBUTION, INCLUDING OPENINGS IN THE FABRIC DUCT TO
PROVIDE PROPER AIR FLOW TO THE SPACE, IS BY THE FABRIC DUCT
MANUFACTURER. REFER TO FABRIC DUCTWORK DIFFUSER SCHEDULE ON
DRAWING M-702.
4 ADJUSTABLE FLOW DEVICE. LOCATION AND TYPE PER FABRIC DUCT
MANUFACTURER INSTALLATION INSTRUCTIONS.
5 16"X34" E.A. DUCT UP TO MECHANICAL PLATFORM.
6 14"Ø S.A. DUCT FROM ABOVE.
7 14"Ø S.A. DUCT DOWN TO DIFFUSER.
8 R.A. DUCT FULL-SIZE OF R.A. DUCT CONNECTION. ELBOW DUCT UP TO
BELLMOUTH OPENING WITH WIRE MESH COVER.
9 INSTALL FAN HIGH IN SPACE. REFER TO ARCHITECTURAL FOR LOCATION.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross
C12C11C10C9C8
CA
CF
C13
FCU-1C
FCU-3C
CUF-3C
UH-1C
CUF-1C
UH-1C
UH-1C
UH-1C
LIFE
SAFETY
STORAGE
C109
BOAT
MAINTENANCE
C101
PARTS
C105
WOMENS
C106
MENS
C108
OFFICE
C110
MH102C
C3
HWS
HWS
HWR
H W
S
HWR
EF-3C EA
LOUVER,
SEE ARCH.
FOR SIZE &
LOCATION
CUF-2C
CUF-4C
FCU-2C
CD-1
190 CD-1
RG-1
RG-1
12"x10"
12"x10"
EG-2
110 EG-1
EG-1
EG-1
EG-2
BB
C104
2"2"
2"2"
2"2"
3/4"3/4"
1"1"
2"2"
2"2"
HWR
8"ø 8"ø
12"x10"
12"x10"
6"x6" 6"x6"
36"x14"
26"x14"
12"ø
S E
E H
M
1C F
O R
C O
N T
D D D D
3/4"3/4" 1 1/4"1 1/4"
1 1/4"1 1/4"
2"2"
2"2"
1"1"
2"2"
1"1"
H W
R
3/4"3/4"
2"2"
D
1"1"1"1"
R L/
R S
RUN PIPES TIGHT TO
STRUCTURE
OA LOUVER, SEE
ARCH. FOR SIZE
& LOCATION
OA LOUVER, SEE
ARCH. FOR SIZE
& LOCATION
EWH-1 EWH-1 EWH-1 EWH-1
CH-1
HP-1
ACHP-1
EF-4C
6"ø
6" VENT CAP
12"x12" OA
INTAKE
LOUVER
D3/4" D
RL/RS
D3/4" D 12"x12" 12"x12"
8"ø 10"ø
TG-1TG-1
TG-1
RG-1
OFFICE
C111
OFFICE
C110
RD-1
RG-2
14"ø
FCU-4C
FABRIC DUCT
400 CFM (B)
1 1/4"1 1/4"
T
T
SUSPEND UNIT
HEATER 9'-0"
AFF, TYP.
SUSPEND UNIT
HEATER 9'-0"
AFF, TYP.
SUSPEND UNIT
HEATER 9'-0"
AFF, TYP.
C11
CF
HWP-2C
ADS-1CB-1CB-2C
ET-1C
C1
MH102C
SUSPENDED
FROM ABOVE
HWS2" HWS
2" HWR
1" D
DN TO
FLOOR
DRAIN
UH-1C
HWP-1C
HIGH
LOW
B-3C
3BAS
EMERGENCY RED MUSHROOM
SHUTOFF SWITCH. WHEN PUSHED
BOILERTS ARE SHUT DOWN AND NC
SOLENOID VALVE IN GAS MAIN CLOSES
STOPPING GAS FLOW TO BOILERS.FIRST FLOOR
0' - 0"
C11
HWP-2CADS-1C
B-1C
B-2C
ET-1C
2" HWS
2" HWR
B-3C
HWP-1C
53 TYP. 3
BAS
1. MECHANICAL CONTRACTOR SHALL CLOSELY COORDINATE THE INSTALLATION
OF THE MECHANICAL SYSTEM WITH ALL DISCIPLINE CONTRACTORS.
2. ALL MECHANICAL EQUIPMENT AND INSTALLATION SHALL YIELD COMPLETE AND
OPERATIONAL SYSTEMS THAT CONFORM TO THE REQUIREMENTS OF THE
CONTRACT PLANS, SPECIFICATIONS, AND ALL APPLICABLE CODE AND UFC
REQUIREMENTS.
3. LOCATE ALL EQUIPMENT TO ALLOW FOR FULL ACCESS FOR MAINTENANCE.
4. ANY FRESH AIR INTAKES SHALL BE LOCATED A MINIMUM OF 10'-0" ABOVE GRADE
PER ATFP REQUIEMENTS.
5. EXPOSED DUCTWORK IS DOUBLE-WALL SPIRAL W/ PERFORATED INNER LINER
AND MYLAR COATING OVER LINER, UNLESS OTHERWISE NOTED ON PLANS.
6. INSULATE DUCTWORK AND PIPING THROUGH WALL PENETRATIONS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
MH102C
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
R R
F
LO
O R
P
LA
N
A R
E A
B
DAC
12827122
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
SCALE: 1/8" = 1'-0"
RR456 FLOOR PLAN - AREA B
AREA A AREA B
SCALE: 1/4" = 1'-0"
C3
RR456 - ENLARGED BOILER RM. C107
SCALE: 1/4" = 1'-0"
C1
BOILER RM. C107 SECTION
1 GRADE MOUNTED HEAT PUMP. INSTALL AND SECURE UNIT TO CONCRETE
PAD. ROUTE REFRIGERANT PIPING TO AFFILIATED INDOOR AIR HANDLING
UNIT.
2 ADJUST AND BALANCE OUTSIDE AIR INTAKE AIRFLOW RATE TO AIRFLOW
RATE INDICATED ON THE SCHEDULE.
3 ROUTE 2" FLUE VENT UP THRU ROOF TO ROOF CAP. ROUTING OF FLUE,
INCLUDING MATERIAL OF PIPE AND ROOF CAP PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
4 AIR DISTRIBUTION, INCLUDING OPENINGS IN THE FABRIC DUCT TO
PROVIDE PROPER AIR FLOW TO THE SPACE, IS BY THE FABRIC DUCT
MANUFACTURER. REFER TO FABRIC DUCTWORK DIFFUSER SCHEDULE ON
DRAWING M-702.
5 2" COMBUSTION INTAKE DUCTS FROM ROOF CAP TO BOILERS PER
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
6 UNDERCUT DOOR 1 1/2".
7 R.A. DUCT FULL-SIZE OF R.A. DUCT CONNECTION. ELBOW DUCT UP TO
BELLMOUTH OPENING WITH WIRE MESH COVER.
8 ROUTE HWS & HWR PIPES STACKED IN CAVITY BETWEEN EXTERIOR WALL
AND STRUCTURAL BRACING, AND ABOVE TRANSLUCENT PANELS.
9 UNDERCUT DOOR 1".
10 ATFP SWITCH.
1/4" = 1' - 0" 0 5' 10' 15'1'
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross
D2 D3 D4 D5D1
DA
DC
DB
STORAGE
BAY
D101
STORAGE
BAY
D103
STORAGE
BAY
D105
STORAGE
BAY
D107
UH-1D
UH-1D
AC-1D
AC-2D
AC-1D
HP-1D
HP-1D
AC-2DCD-1
RG-3
CD-1
CD-1
RG-3
RG-3
RG-3
S E
E M
H
2D F
O R
C O
N T
CD-1
10"ø
8"x8"
8"x8"
10"ø
10"ø
8"x8"
8"x8"
10"ø
SR-1
SR-1
SR-1
SR-1
SR-1
SR-1
SR-1
SR-1
1" D 1" D
OFFICE
D104
OFFICE
D102
OFFICE
D106
OFFICE
D108
UH-1D
4 UH-1D
76"x6"6"x6"
6"x6"6"x6"
32"ø
T
T
T
T
SUSPEND UNIT
HEATER 10'-0"
AFF, TYP.
SUSPEND UNIT
HEATER 10'-0"
AFF, TYP.
SUSPEND UNIT
HEATER 10'-0"
AFF, TYP.
SUSPEND UNIT
HEATER 10'-0"
AFF, TYP.
1. MECHANICAL CONTRACTOR SHALL CLOSELY COORDINATE THE INSTALLATION
OF THE MECHANICAL SYSTEM WITH ALL DISCIPLINE CONTRACTORS.
2. ALL MECHANICAL EQUIPMENT AND INSTALLATION SHALL YIELD COMPLETE AND
OPERATIONAL SYSTEMS THAT CONFORM TO THE REQUIREMENTS OF THE
CONTRACT PLANS, SPECIFICATIONS, AND ALL APPLICABLE CODE AND UFC
REQUIREMENTS.
3. LOCATE ALL EQUIPMENT TO ALLOW FOR FULL ACCESS FOR MAINTENANCE.
4. ANY FRESH AIR INTAKES SHALL BE LOCATED A MINIMUM OF 10'-0" ABOVE GRADE
PER ATFP REQUIEMENTS.
5. EXPOSED DUCTWORK IS DOUBLE-WALL SPIRAL W/ PERFORATED INNER LINER
AND MYLAR COATING OVER LINER, UNLESS OTHERWISE NOTED ON PLANS.
6. INSULATE DUCTWORK AND PIPING THROUGH WALL PENETRATIONS.
D7
DC
RG-2
RG-2
RG-2
"x
"x
42"x20"
AHU-1D
"x
40"ø
C2
MH101D
EUH-1
BAS
FIRST FLOOR
0' - 0"
DC
DB
40"ø 32"ø
20"x60"
42"x20"
20"x42" 26 "x
26"x52"
MOTORIZED
DAMPERS
42"x20"
AHU-1D
RG-2
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
MH101D
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
R R
F
LO
O R
P
LA
N
A R
E A
A
DAC
12827123
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
SCALE: 1/8" = 1'-0"
RR469 FLOOR PLAN - AREA A
AREA A AREA B
SCALE: 1/4" = 1'-0"
C3
RR469 ENLARGED UTILITY PLAN
SCALE: 1/8" = 1'-0"
C2
RR469 - BUILDING SECTION
1 GRADE MOUNTED HEAT PUMP. INSTALL AND SECURE UNIT TO CONCRETE
PAD. ROUTE REFRIGERANT PIPING TO AFFILIATED INDOOR AIR HANDLING
UNIT.
2 CONDENSATE PIPE TO SLASH BLOCK ON GRADE.
3 ROUTE CONDENSATE PIPE DOWN TO FLOOR DRAIN FOR INDIRECT
CONNECTION.
4 CONCENTRIC CUMBUSTION FLUE, COMBUSTION AIR INTAKE THROUGH
ROOF, SIZE OF VENT AND MATERIAL PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
5 ADJUST AND BALANCE OUTSIDE AIR INTAKE AIRFLOW RATE TO AIRFLOW
RATE INDICATED ON THE SCHEDULE.
6 R.A. DUCTWORK - DOUBLE WALL WITH PERFORATED INNER LINER AND
MYLAR LAYER OVER LINER.
7 O.A. INTAKE LOUVER, SEE ARCHITECTURAL FOR SIZE AND LOCATION.
1/4" = 1' - 0" 0 5' 10' 15'1'
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross
D6 D7 D8 D9 D10 D11
DA
DC
DB
OFFICE
D110A
OFFICE
D110B
STORAGE
BAY
D113
UH-1D
UH-1D
EF-1DEF-1D
AC-2D
UH-1D
AC-2D
26"ø
S E
E M
H
1D F
O R
C O
N T
CD-1
RG-3
SR-1
SR-1
SR-1
SR-1
SR-1
SR-1
STORAGE
BAY
D111
STORAGE
BAY
D109
SA
FROM
AHU-1D
1" D
CD-1
280 RG-3
ACCU-1D
HP-1D
OFFICE
D114
OFFICE
D112
SUSPEND GAS FIRED
UNIT HEATER 10'-0"
AFF, TYP.
D
D
C2
MH101D
DOUBLE WALL SPIRAL
DUCTWORK W/ PERFORATED
INNER LINER & MYLAR
COATING OVER LINER
UH-1D
DOUBLE WALL SPIRAL
DUCTWORK W/ PERFORATED
INNER LINER & MYLAR
COATING OVER LINER
EA LOUVER, SEE
ARCH. FOR SIZE &
LOCATION
STORAGE
BAY
D109
T
AHU-1D
3/4"3/4"
CU-1
CU-1
D
SR-1
SR-1
SR-1
SR-1
SR-1
SR-1
AC-1
AC-1
UTILITY
ROOM
D115
TELECOM
D118
ELECTRICAL
D119
3/4"3/4"
MH101D
C3
40"ø
32"ø
6"x6" 10"ø
8"x8" 6"x6" 8"x8"
6"x6" 6"x6"
6"x6"
10"ø
RG-3
CD-1
CD-1
RG-3
EWH-1
EWH-1
12"x10"
T T
8"x8" 10"ø
"ø
8"x8"SUSPEND UNIT
HEATER 10'-0"
AFF, TYP.
SUSPEND UNIT
HEATER 10'-0"
AFF, TYP.
AC-2DAC-1D
1. MECHANICAL CONTRACTOR SHALL CLOSELY COORDINATE THE INSTALLATION
OF THE MECHANICAL SYSTEM WITH ALL DISCIPLINE CONTRACTORS.
2. ALL MECHANICAL EQUIPMENT AND INSTALLATION SHALL YIELD COMPLETE AND
OPERATIONAL SYSTEMS THAT CONFORM TO THE REQUIREMENTS OF THE
CONTRACT PLANS, SPECIFICATIONS, AND ALL APPLICABLE CODE AND UFC
REQUIREMENTS.
3. LOCATE ALL EQUIPMENT TO ALLOW FOR FULL ACCESS FOR MAINTENANCE.
4. ANY FRESH AIR INTAKES SHALL BE LOCATED A MINIMUM OF 10'-0" ABOVE GRADE
PER ATFP REQUIEMENTS.
5. EXPOSED DUCTWORK IS DOUBLE-WALL SPIRAL W/ PERFORATED INNER LINER
AND MYLAR COATING OVER LINER, UNLESS OTHERWISE NOTED ON PLANS.
6. INSULATE DUCTWORK AND PIPING THROUGH WALL PENETRATIONS.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
MH102D
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
R R
F
LO
O R
P
LA
N
A R
E A
B
DAC
12827124
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
SCALE: 1/8" = 1'-0"
RR469 FLOOR PLAN - AREA B
AREA A AREA B
1 GRADE MOUNTED HEAT PUMP. INSTALL AND SECURE UNIT TO CONCRETE
PAD. ROUTE REFRIGERANT PIPING TO AFFILIATED INDOOR AIR HANDLING
UNIT.
2 CONDENSATE PIPE TO SLASH BLOCK ON GRADE.
3 CONCENTRIC CUMBUSTION FLUE, COMBUSTION AIR INTAKE THROUGH
ROOF, SIZE OF VENT AND MATERIAL PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
4 ADJUST AND BALANCE OUTSIDE AIR INTAKE AIRFLOW RATE TO AIRFLOW
RATE INDICATED ON THE SCHEDULE.
5 ROUTE CONDENSATE PIPE DOWN TO FLOOR DRAIN FOR INDIRECT
CONNECTION.
6 O.A. INTAKE LOUVER, SEE ARCHITECTURAL FOR SIZE AND LOCATION.
7 ATFP SWITCH.
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross
1"
COIL
DRAIN
PAN
NOTES
1. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR
TRAP. COORDINATE MOUNTING OF HVAC UNIT ON
EQUIPMENT PAD TO PROVIDE SUFFICIENT HEIGHT.
2. PITCH DRAIN PIPE FOR PROPER RUN-OFF.
3. MANUALLY PRIME FILL TRAP BEFORE START-UP TO
FORM INITIAL DRAIN SEAL.
4. SUPPORT DRAIN LINES TO PREVENT SAG AND
CONDENSATE OVERFLOW.
5. INSTALL A CLEANOUT TEE AT EACH CHANGE OF
DIRECTION GREATER THAN 45°.
6. MAXIMUM DISTANCE BETWEEN CLEANOUTS TO BE 50
LINEAR FEET.
CONDENSATE DRAIN SIZING
UNIT SIZE*3/4"
1" UP TO 2 TONS
1-1/4" UP TO 5 TONS
1-1/2" UP TO 30 TONS
UP TO 50 TONS
UP TO 150 TONS
UP TO 300 TONS
UP TO 430 TONS
2"
3"
4"
6"
PIPE SIZE
RETURN BEND
PITCH DN
DRAIN CONNECTION
NIPPLE
TEE
CLEANOUT PLUG
DISCHARGE MUST BE
BELOW LEVEL OF
DRAIN PAN
CONDENSATE DRAIN DETAIL
NO SCALE
*MINIMUM CONDENSATE DRAIN PIPE SIZE
CLEAN-OUT TEE WITH THREADED PLUG
POSITIVE PRESSURE TRAP NEGATIVE PRESSURE TRAP
K = MIN. 1/2"
H = 1/2" PLUS MAX. TOTAL STATIC PRESSURE
J = HALF OF H
H = 1" PLUS MAX. NEG. STATIC PRESSURE
K H
H J
NO SCALE
TYPICAL MANUAL AIR VENT DETAILS
NOTES:
EXTEND VENT LINE TO WITHIN 6" ABOVE CEILING WHERE
PIPING IS CONCEALED ABOVE CEILING. WHERE PIPING IS
EXPOSED, VALVE SHALL BE LOCATED WITHIN 72" OF
FINISHED FLOOR.
ALL AIR VENTS ARE TO BE MANUAL TYPE. THE ONLY
EXCEPTION SHALL BE THOSE THAT ARE PART OF AN AIR
SEPARATOR OR MFG EQUIPMENT SUCH AS BOILER.
SYSTEM PIPE
1/2" BALL VALVE
1/2"
3/4" HOSE
THREAD
1/2" BALL VALVE LOCATED
TO ALLOW ACCESSIBILITY
FROM BELOW CEILING
1/2"SYSTEM PIPE
3/4" HOSE
THREAD
SYSTEM PIPE
3/4" HOSE
THREAD
1/2" BALL VALVE
LOCATED TO ALLOW
ACCESSIBILITY FROM
BELOW CEILING
1/2"
6" LONG NIPPLE,
SAME SIZE AS
SYSTEM PIPE
PIPE CAP
CLEVIS HANGER SP-69,
TYPE 1
SUPPORT FROM
STRUCTURE ABOVE
1/2"Ø HANGER R0D
PIPE
2"Ø THREADED ROD SUPPORT FROM
STRUCTURE ABOVE
1-1/2"x1-1/2"x1/4"
STEEL ANGLE
BOLT AND CLAMPING
NUT (TYP)
STEEL PIPE/DUCT
STRAP
INSULATION SADDLE
MULTIPLE PIPE/DUCT RUNS
NO SCALE
PIPE/DUCT SUPPORT DETAILS
INSULATION SHIELD
INSULATION
INSULATION SADDLE
INSULATION SHIELD
INSULATION
AHU HEATING WATER COIL PIPING DETAIL
NO SCALE
RETURN
SUPPLY
MAKE-UP WATER PIPING DETAIL
NO SCALE
BY DIV 22BY DIV 23
TO HEATING
WATER MAKE-UP
3/4"
SCREWED UNION (TYP.)
GLOBE VALVE N.C. (TYP.)
PRESSURE REDUCING VALVE
PRESSURE RELIEF VALVE (TYP.)
STRAINER (TYP.)
ISOLATION VALVE (TYP.)
1"
PRESSURE REDUCING VALVE SETTING, IN FEET WATER COLUMN, TO BE EQUAL TO 12 FEET WATER COLUMN PLUS THE ELEVATION DIFFERENCE, IN FEET, BETWEEN THE VALVE AND THE HIGHEST POINT OF THE HYDRONIC
PRESSURE GAUGE
NOTE:
SYSTEM IT SERVES
REDUCED PRESSURE
PRINCIPLE BACKFLOW
PREVENTION ASSEMBLY
A3A1
B1
D1
C3
NOTES
DRAIN TEE CONNECTIONS PROVIDE MEANS TO FLUSH COIL
INDEPENDENT OF THE REMAINDER OF THE SYSTEM AND WITHOUT
FLOWING THROUGH THE CONTROL VALVE.
THE PRESSURE INDEPENDENT CONTROL VALVE SHALL BE INSTALLED
IN CONFORMANCE WITH THE VALVE MFGR'S RECOMMENDED SPACING
UPSTREAM AND DOWNSTREAM FROM CHANGES IN PIPE DIRECTION,
AND/OR OTHER VALVES AND COMPONENTS IN THE PIPING.
CALIBRATED FLOW MEASURING DEVICE OR VENTURI AND ISOLATION
VALVE MAY BE COMBINED INTO ONE ASSEMBLY. PROVIDE 2 PIPE
DIAMETERS DOWNSTREAM AND 5 UPSTREAM OF CALIBRATED FLOW
MEASURING DEVICE OR VENTURI.
ONLY STRAIGHT STEEL OR COPPER PIPE SHALL BE BETWEEN THE P/T
PORT AND THE COIL AND THE MAXIMUM LENGTH OF PIPE IS TO BE 5 LF.
ISOLATION VALVES ARE TO BE OF THE VALVE TYPE SPECIFIED AND TO
BE INSTALLED TO ALLOW SERVICE AND REMOVAL OF ALL EQUIPMENT,
ACCESSORIES, AND APPURTENANCES WITHOUT SYSTEM SHUTDOWN.
AIR VENT TO BE INSTALLED SO THE POINT OF THE VENT PIPING
CONNECTION IS ABOVE THE HIGHEST POINT OF THE COIL AND ITS
AFFILIATED PIPING. AIR VENT MAY BE PART OF THE COIL OR
INSTALLED SEPARATELY.
TEE CONNECTIONS PROVIDE MEANS TO FLUSH BRANCH PIPING
WITHOUT FLOWING THROUGH COIL AND CONTROL VALVE.
ARRANGE PIPING TO PERMIT REMOVAL OF COIL.
FOR STACKED OR SPLIT COILS THE INSTALLATION OF EACH COIL
SHALL INCLUDE AN ISOLATION VALVE, P/T PORT, AND FLANGED OR
UNION CONNECTION FOR EACH PIPE, A BALANCING VALVE IN EACH
RETURN, AND A DRAIN TEE FOR EACH COIL. RELATIVE POSITIONS OF
COMPONENTS TO BE AS ILLUSTRATED IN THIS DETAIL.
CALIBRATED BALANCING VALVE
3/4" DRAIN VALVE WITH HOSE
CONNECTIONS WITH CAP (TYP)
CAPPED TEE FOR
FLUSHING (TYP)
ISOLATION VALVE (TYP)
CALIBRATED FLOW
MEASURING DEVICE
OR VENTURI WITH P/T PORTS.
PRESSURE INDEPENDENT
2-WAY MODULATING
CONTROL VALVE
MANUAL AIR VENT
UNLESS SPECIFIED TO BE AUTOMATIC
UNION OR FLANGES (TYP)
STRAINER
PRESSURE GAGE (TYP)
THERMOMETER 50-250 °F (TYP)
P/T PORT (TYP)
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
M-501
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
D E
T A
IL
S
DAC
12827125
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross
COIL
ELEVATION
SECTION
SEE NOTE
STEEL PIPE
2" X 2" ANGLE IRON
PIPE INSULATION
5/8" (MINIMUM) DIA HEAVYSCREW
ANCHOR. MIN TENSION CAPACITY = 500
LB. 2 PER ANGLE
4" X 12" X 3/8" STEEL ANCHOR PLATE.
WELD TO PIPE, BOTH SIDES
3" X 3" X 3/8" STEEL
ANGLE
WELD BOTH SIDES OF ANCHOR PLATE TO PIPE
WITH 3/16 INCH FILLET WELD
STEEL PIPE,
2 1/2" DIA MAX
3' -0
M
A X
3/16
3/16
EA
END
1/4
1/4
EA
END
NO SCALE
PIPE ANCHOR DETAIL
NOTE: EXPANSION TYPE HANGERS BETWEEN MOMENT GUIDES AND ANCHOR ON EACH
SIDE OF ANCHOR
MOMENT GUIDE LOCATED 14
FEET EACH SIDE OF ANCHOR
MOMENT GUIDE LOCATED 14
FEET EACH SIDE OF ANCHOR
2" X 2" X 1/4" STEEL
ANGLE
HORIZONTAL DUCTWORK SUPPORT SCHEDULE
PAIR AT 10FT
SPACING
P/2=30"
MAXIMUM HALF OF
DUCT PERIMETER
P/2=72"
P/2=96"
P/2=120"
P/2=168"
STRAP WIRE/ROD
1"x22ga 10ga(.135")
1"x18ga
1"x16ga
11/2"x16ga
11/2"x22ga
3/8"
3/8"
1/2"
1/2"
PAIR AT 8FT
SPACING
STRAP WIRE/ROD
1"x22ga 10ga(.135")
1"x20ga 1/4"
1"x18ga 3/8"
1"x16ga 3/8"
1/2"11/2"x16ga
PAIR AT 5FT
SPACING
STRAP WIRE/ROD
1"x22ga 12ga(.106")
1"x22ga 1/4"
1"x20ga 3/8"
1"x18ga 3/8"
3/8"1"x16ga
STRAP WIRE/ROD
1"x22ga 12ga(.106")
1"x22ga 1/4"
1"x22ga 1/4"
1"x20ga 1/4"
3/8"
PAIR AT 4FT
SPACING
1"x18ga
24" DIA. MAX
(WIRE HANGERS
NOT PERMITTED)
42" DIA. MAX
STRAP
HANGER
LOAD RATED
FASTENER
BAND (1)
11/2"x18ga
NO SCALE
TYPICAL HORIZONTAL ROUND DUCT
SUPPORTS DETAIL AND SCHEDULE
NOTES:
1. HANGER SIZE.
2. FOR DUCT ATTACHMENT TO BUILDING CONSTRUCTION. SEE TABLE BELOW FOR HORIZONTAL DUCTWORK SUPPORT
SCHEDULE.
3. FOR SEISMIC REQUIREMENTS REFER TO (NUSIG) NATIONAL UNIFORM SEISMIC INSTALLATION GUIDELINES.
4. HANG EACH DUCT INDEPENDENTLY.
5. HANGER STRAPS AND RODS ARE TO BE VERTICAL.
6. HANG FROM STRUCTURE.
RETURN AIR
SUPPLY AIR
45°
6"
BRANCH DUCT
NO SCALE
BRANCH DUCT CONNECTION DETAIL
FACTORY INSULATED FLEXIBLE DUCT
(WHERE ALLOWED), FULL NECK SIZE OF
DIFFUSER. 5' - 0" MAXIMUM LENGTH
CEILING
SEALANT AND CLAMP
SEALANT AND CLAMP
2 TIMES THE DUCT DIAMETER
NO SCALE
FLEXIBLE DUCT CONNECTION DETAIL
DIFFUSER
RIGID DUCT MINIMUM LENGTH OF
NO SCALE
SINGLE DUCT VAV TERMINAL UNIT DETAIL
METAL STRAP HANGERS SECURED
TO VAV & TO STRUCTURE (TYP)
MIN. 3 DUCT DIAM.
STRAIGHT RIGID DUCT ON
AIR TERMINAL INLET
COMPRESSION STRAP
TO ENSURE
AIRTIGHT JOINT
AIR TERMINAL
CONTROL PANEL
HEATING WATER COIL
DUCT
FLEXIBLE DUCT
12-INCHES MAXIMUM
LENGTH
NO SCALE
FAN COIL UNIT AND UNIT HEATER HEATING WATER COIL PIPING DETAIL
RETURN
SUPPLY
B3B2
C2
A1 A2 A4
NOTES
DRAIN TEE CONNECTIONS PROVIDE MEANS TO FLUSH COIL
INDEPENDENT OF THE REMAINDER OF THE SYSTEM AND WITHOUT
FLOWING THROUGH THE CONTROL VALVE.
THE CONTROL VALVES AND AUTOMATIC FLOW CONTROL VALVES SHALL
BE INSTALLED IN CONFORMANCE WITH THE VALVE MFGR'S
RECOMMENDED SPACING UPSTREAM AND DOWNSTREAM FROM
CHANGES IN PIPE DIRECTION, AND/OR OTHER VALVES AND
COMPONENTS IN THE PIPING.
CALIBRATED FLOW MEASURING DEVICE OR VENTURI AND AUTOMATIC
FLOW CONTROL VALVE MAY BE COMBINED INTO ONE ASSEMBLY.
PROVIDE 2 PIPE DIAMETERS DOWNSTREAM AND 5 UPSTREAM OF
CALIBRATED FLOW MEASURING DEVICE OR VENTURI.
ONLY STRAIGHT STEEL OR COPPER PIPE SHALL BE BETWEEN THE P/T
PORT AND THE COIL AND THE MAXIMUM LENGTH OF PIPE IS TO BE 5 LF.
ISOLATION VALVES ARE TO BE OF THE VALVE TYPE SPECIFIED AND TO
BE INSTALLED TO ALLOW SERVICE AND REMOVAL OF ALL EQUIPMENT,
ACCESSORIES, AND APPURTENANCES WITHOUT SYSTEM SHUTDOWN.
AIR VENT TO BE INSTALLED SO THE POINT OF THE VENT PIPING
CONNECTION IS ABOVE THE HIGHEST POINT OF THE COIL AND ITS
AFFILIATED PIPING. AIR VENT MAY BE PART OF THE COIL OR INSTALLED
SEPARATELY.
TEE CONNECTIONS PROVIDE MEANS TO FLUSH BRANCH PIPING
WITHOUT FLOWING THROUGH COIL AND CONTROL VALVE.
ARRANGE PIPING TO PERMIT REMOVAL OF COIL.
PROVIDE 3-WAY VALVES WHERE INDICATED ON THE DRAWINGS. SEE
THE CHILLED WATER CONTROL AND FLOW DETAIL.
PIPING COMPONENTS ARE INSTALLED BY, AND INCLUDED WITH, THE
PACKAGED FCU.
CONTROL VALVES, RELAYS, TRANSFORMERS, AND CONTROLLERS ARE
TO BE PROVIDED BY THE CONTROLS CONTRACTOR TO THE FCU
MANUFACTURER, WHO INSTALLS THEM.
FOR STACKED OR SPLIT COILS THE INSTALLATION OF EACH COIL SHALL
INCLUDE AN ISOLATION VALVE, P/T PORT, AND FLANGED OR UNION
CONNECTION FOR EACH PIPE, A BALANCING VALVE IN EACH RETURN,
AND A DRAIN TEE FOR EACH COIL. RELATIVE POSITIONS OF
COMPONENTS TO BE AS ILLUSTRATED IN THIS DETAIL.
CALIBRATED FLOW MEASURING
DEVICE OR VENTURI
DEVICE WITH P/T PORTS.
3/4" DRAIN VALVE WITH HOSE
CONNECTIONS WITH CAP (TYP)
ISOLATION VALVE (TYP)
CAPPED TEE FOR
FLUSHING (TYP)
MANUAL AIR VENT UNLESS
SPECIFIED TO BE AUTOMATIC
3-WAY 2-POSITION OR 2-WAY
2-POSITION CONTROL VALVE
BALANCING VALVE
UNION (TYPICAL)
STRAINER
P/T PORT (TYP)
VOLUME DAMPER
(WHERE INDICATED)
INSULATION
RIGID ELBOW
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
M-502
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
D E
T A
IL
S
DAC
12827126
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross
GENERAL
1. ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL YIELD COMPLETE OPERATIONAL SYSTEMS THAT CONFORM TO THE REQUIREMENTS OF THE APPLICABLE LOCAL ORDINANCES AND CODES
INCLUDING BUT NOT LIMITED TO THE INTERNATIONAL BUILDING CODES, UFC REQUIREMENTS, AND UNDERWRITERS LABORATORIES (OR ETL).
2. THE CONTRACT DOCUMENTS ARE BASED ON EQUIPMENT OF SPECIFIC MANUFACTURERS. IF THE CONTRACTOR SUBMITS OR PROPOSES TO USE EQUIPMENT OTHER THAN THAT USED ON THE CONTRACT
DOCUMENTS THEN THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DESIGN AND INSTALLATION REVISIONS AT NO ADDITIONAL COST TO THE PROJECT. REVISIONS INCLUDE BUT ARE NOT LIMITED TO, CHANGES IN EQUIPMENT DIMENSIONS OR WEIGHT, ACCESS REQUIREMENTS, ORIENTATION AND CONNECTIONS, AND ELECTRICAL REQUIREMENTS.
3. EQUIPMENT OF A SIMILAR TYPE SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER.
4. DO NOT SCALE DRAWINGS. DRAWINGS ARE DIAGRAMMATIC.
5. CONTRACTORS ARE TO PREPARE AND SUBMIT COORDINATION DRAWINGS IN ACCORDANCE WITH SPECIFIC REQUIREMENTS. COORDINATION DRAWINGS SHALL BE COMPLETED AND REVIEWED PRIOR TO
THE PURCHASING OF ANY EQUIPMENT.
6. INSTALLATION OF PIPING, DUCTWORK, AND EQUIPMENT SHALL NOT BE STARTED PRIOR TO SUBMISSION AND APPROVAL OF THE CONTRACTOR DEVELOPED COORDINATION DRAWINGS THAT INCLUDE, BUT ARE NOT LIMITED TO, SHOWING PLUMBING, FIRE SUPPRESSION, HVAC, ARCHITECTURAL, STRUCTURAL, ELECTRICAL POWER, LIGHTING AND TELECOM WORK. ANY WORK INSTALLED PRIOR TO THE
APPROVAL OF THE COORDINATION DRAWINGS MAY NEED TO BE REMOVED, RELOCATED, OR ADJUSTED WITH NO IMPACT ON THE PROJECT SCHEDULE OR PROJECT COST.
7. SHOP DRAWINGS INCLUDING, BUT NOT LIMITED TO, PRODUCT INFORMATION SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT BEFORE ANY MECHANICAL EQUIPMENT IS ORDERED, PURCHASED, RELEASED, OR FABRICATED. SHOP DRAWINGS AND SUBMITTALS SHALL INCLUDE PRODUCT INFORMATION FOR ALL EQUIPMENT SPECIFIED OR SCHEDULED ON THE DRAWINGS;
COORDINATION DRAWINGS SHALL BE COMPLETED AND REVIEWED PRIOR TO THE PURCHASING OF ANY EQUIPMENT.
8. ALL MATERIALS AND EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS FOR THE INTENDED PURPOSE. USE THE MORE STRINGENT METHODS WHEN
MANUFACTURERS RECOMMENDATIONS AND PLANS AND SPECIFICATION INFORMATION DIFFER. BRING ANY CONFLICTS BETWEEN MANUFACTURERS RECOMMENDATIONS AND PLANS AND SPECIFICATIONS
REQUIREMENTS TO THE GOVERNMENTS ATTENTION.
9. ALL EQUIPMENT AND MATERIALS INSTALLED IN AIR PLENUMS SHALL BE COMPLIANT WITH THE REQUIREMENTS FOR PLENUM INSTALLATIONS.
10. BEFORE THE PROJECT IS CONSIDERED SUBSTANTIALLY COMPLETE, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND BALANCED IN ACCORDANCE WITH AABC OR NEBB STANDARDS, TO
DELIVER THE AIR AND WATER FLOW QUANTITIES SHOWN ON THE DRAWINGS. A CERTIFIED TEST AND BALANCE REPORT SHALL BE SUBMITTED TO, AND APPROVED BY THE ENGINEER. FURNISH AND
INSTALL ADJUSTMENT AND BALANCING DEVICES, (DAMPERS, VALVES, AND SHEAVES) AS REQUIRED AT NO ADDITIONAL COST TO THE PROJECT.
11. PERMANENTLY MARK FINAL SETTINGS ON BALANCING DEVICES.
12. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF TWELVE MONTHS AFTER ACCEPTANCE BY OWNER.
13. AT SUBSTANTIAL COMPLETION ALL FILTERS IN ALL MECHANICAL EQUIPMENT SHALL BE NEW AND CLEAN.
14. CONTRACTOR TO PROVIDE A LISTING OF THE HVAC FILTERS FOR EACH PIECE OF EQUIPMENT ALONG WITH THE DIMENSIONS (WIDTH, HEIGHT, THICKNESS, AND EFFICIENCY) AND TYPE. CONTRACTOR TO
PROVIDE TWO EXTRA SETS OF FILTERS. CONTRACTOR TO PROVIDE AND CHANGE ALL FILTERS AT SECOND SEASON OF TEST AND BALANCE (TAB). IN ALL CONTRACTOR TO PROVIDE 5 SETS OF FILTERS; 1
FOR START-UP, 3 FOR THE GOVERNMENT, AND 1 AT THE SECOND SEASON OF TAB.
15. FURNISH AND INSTALL DUCTWORK AND PIPE TRANSITIONS REQUIRED AT EQUIPMENT CONNECTIONS.
16. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, DUCTWORK, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS.
CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT.
17. LOCATE ALL EQUIPMENT TO PRODUCE UNOBSTRUCTED ACCESS TO EQUIPMENT ACCESS PANELS, CONTROLS, AND VALVING.
18. FURNISH AND INSTALL ACCESS DOORS AND PANELS IN NON-ACCESSIBLE CEILINGS AND IN WALL STRUCTURES TO YIELD ADEQUATE SPACE FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF
SYSTEMS. ACCESS DOORS AND PANELS SHALL BE INSTALLED WHERE SHOWN ON THE DRAWINGS OR AS NECESSARY TO PRODUCE ACCESS TO DAMPERS, VALVES, ETC. COORDINATE EXACT LOCATION
OF ALL ACCESS PANELS AND DOORS WITH THE ARCHITECT DURING THE SHOP DRAWING PROCESS.
19. INSTALL DUCT MOUNTED ACCESS DOORS AND PANELS FOR INSPECTION AND REPAIR AT ALL MOTOR OPERATED DAMPERS. INSTALL ACCESS DOORS AND PANELS IN DUCTWORK FOR OPERATION, ADJUSTMENT, AND MAINTENANCE OF ALL FANS, VALVES, AND MECHANICAL EQUIPMENT. INSTALL DOORS TO SWING AGAINST DUCT STATIC PRESSURE. MINIMUM ACCESS PANEL OR DOOR SIZE SHALL BE
5-INCHES BY 8-INCHES. SIZE PANELS AND DOORS 2-INCHES SMALLER THAN THE DUCT DIMENSION IN WHICH THE DOOR IS INSTALLED UP TO 24-INCHES MAXIMUM.
20. INSTALL ALL TEMPERATURE, PRESSURE, AND FLOW MEASURING DEVICES IN ACCESSIBLE LOCATIONS WHERE THE MANUFACTURER'S RECOMMENDED MINIMUM LENGTHS OF STRAIGHT DUCTWORK OR
PIPE ARE PROVIDED UPSTREAM AND DOWNSTREAM OF THE DEVICE.
21. FURNISH AND INSTALL A THERMOSTAT, OR IF CONTROL IS THRU A CONTROL SYSTEM THEN A TEMPERATURE SENSOR, FOR ANY DEVICE REQUIRING A THERMOSTAT OR SENSOR FOR CONTROL WHETHER
THE THERMOSTAT OR SENSOR IS INDICATED ON THE DRAWINGS OR NOT.
22. PRIOR TO INSTALLATION OBTAIN APPROVAL FROM ARCHITECT FOR LOCATIONS OF ALL THERMOSTATS AND SENSORS LOCATED EXPOSED IN FINISHED AREAS.
23. PRIOR TO INSTALLATION, THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES THE LOCATIONS OF AIR CONDITIONING EQUIPMENT INSTALLED OUTDOORS.
24. AIR CONDITIONING EQUIPMENT INSTALLED OUTDOORS AT GRADE SHALL BE INSTALLED LEVEL ON 4-INCH THICK REINFORCED CONCRETE PADS THAT EXTEND 6-INCHES BEYOND THE PERIMETER OF THE
EQUIPMENT.
25. FREEZESTATS OR LOW LIMIT SENSORS FOR AIR STREAMS ARE TO BE SERPENTINE TUBE TYPE INSTALLED IN A VERTICAL PLANE TO DETECT TEMPERATURE ACROSS THE CROSS SECTIONAL AREA OF THE
AIR FLOW.
ELECTRICAL COORDINATION
26. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND ELECTRICAL CONTRACTOR BEFORE
ANY PRODUCT INFORMATION OR SHOP DRAWINGS ARE SUBMITTED AND BEFORE ANY EQUIPMENT IS ORDERED. THE ELECTRICAL CHARACTERISTICS (VOLTAGE, PHASE, OVERLOAD PROTECTION, ETC.) OF
THE EQUIPMENT FURNISHED SHALL BE COMPATIBLE WITH THE ELECTRICAL CHARACTERISTICS SHOWN ON THE DRAWINGS. ON SHOP DRAWING SUBMITTALS THE MECHANICAL CONTRACTOR SHALL
STATE THAT THE ELECTRICAL CHARACTERISITICS OF ALL EQUIPMENT HAS BEEN COORDINATED WITH THE ELECTRICAL CONTRACT DOCUMENTS AND THE ELECTRICAL CONTRACTOR.
27. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT SWITCHES AND STARTERS WHETHER THEY ARE AN INTEGRAL COMPONENT OF THE
MANUFACTURER'S EQUIPMENT OR NOT. COORDINATE SWITCH TYPE (FUSED OR NON-FUSED) WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS, ELECTRICAL DRAWINGS, AND
ELECTRICAL CONTRACTOR.
28. ALL REQUIRED CONTROL WIRING FOR HVAC AND PLUMBING, INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, ACTUATORS, DEVICES, ETC., SHALL BE INCLUDED AS PART OF THE
MECHANICAL WORK. WIRING, INCLUDING THAT IN HVAC PLENUM SPACES, SHALL BE INSTALLED ACCORDING TO CODE REQUIREMENTS.
29. UNLESS NOTED OTHERWISE, STARTERS, TRANSFORMERS, CONTROLS, AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL
CONTRACTOR. SEE ELECTRICAL SPECIFICATIONS FOR WIRING REQUIREMENTS.
30. PROVIDE PHASE MONITORS ON ALL 3-PHASE EQUIPMENT.
SMOKE DETECTION
31. SMOKE DETECTORS SHALL BE INSTALLED (A)WHERE INDICATED ON THE DRAWINGS, (B) IN THE RETURN AIR PATH OF ALL FAN SYSTEMS SUPPLYING MORE THAN 2000 CFM OF AIR EXCEPT WHERE THE AIR
DISTRIBUTION SYSTEM IS INCAPABLE OF SPREADING SMOKE BEYOND THE ENCLOSING WALLS, FLOOR, AND CEILING OF THE SPACE OR ROOM.
32. DUCT SMOKE DETECTOR SELECTION AND LOCATION SHALL BE COORDINATED WITH THE ELECTRICAL CONTRACTOR AND ENGINEER. SMOKE DETECTORS SHALL BE WIRED TO STOP THEIR AFFILIATED
FAN, OR FANS. UPON DETECTION OF SMOKE, THE SMOKE DETECTORS SHALL COMMUNICATE TO THE BUILDING FIRE ALARM PANEL THAT THE COMMAND TO CLOSE THE DAMPER HAS BEEN GENERATED.
SMOKE DETECTOR TROUBLE CONDITIONS SHALL BE IDENTIFIED AS AIR DUCT DETECTOR TROUBLE. SMOKE DETECTORS SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, MOUNTED IN THE
DUCTS BY THE MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR.
33. ALL PIPE AND DUCT PENETRATIONS OF FIRE-, SMOKE-, OR FIRE- AND SMOKE-RATED ASSEMBLIES SHALL BE FIRE-STOPPED AS REQUIRED TO PRODUCE A RATED ASSEMBLY. FIRE BARRIER PRODUCTS
SHALL BE AS MANUFACTURED BY 3M CO., HILTI INC., OR OTHER APPROVED MANUFACTURER. ACCEPTABLE PRODUCTS ARE HILTI FS-ONE, CP 606, CP648 WRAP STRIP, OR CP680 CAST-IN DEVICE SYSTEMS, OR AS RECOMMENDED BY THE MANUFACTURER FOR A PARTICULAR APPLICATION OR AN EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS.
34. DUCTWORK THAT IS ROUTED PARALLEL TO RATED WALLS SHALL BE INSTALLED A MINIMUM OF 6-INCHES FROM RATED WALLS.
35. FOR DUCTWORK PENETRATING FIRE RATED WALLS INSTALL ADDITIONAL SUPPORTS FOR DUCTWORK LOCATED ON EITHER SIDE OF, AND WITHIN 18-INCHES OF, FIRE RATED WALLS. DUCTWORK OR PIPING
SHALL NOT BE SUPPORTED FROM ANY FIRE RATED WALL.
GENERAL DUCTWORK AND AIR DISTRIBUTION
36. LOCATIONS OF AIR DISTRIBUTION DEVICES, GRILLES, REGISTERS, AND DIFFUSERS, SHOWN ON THE DRAWINGS ARE APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, SPRINKLER PIPING, ETC., AND WITH THE ARCHITECTURAL CEILING PLAN.
37. LOCATE AIR SUPPLIES AND RETURNS A MINIMUM OF 3-FEET DISTANCE FROM AREA SMOKE DETECTORS.
38. FLEX CONNECTORS SHALL BE USED FOR ALL CONNECTIONS BETWEEN SHEET METAL DUCTWORK AND MOTOR DRIVEN EQUIPMENT AND AT ALL LOCATIONS WHERE DUCTWORK CROSSES BUILDING
EXPANSION JOINTS. FLEX CONNECTORS SHALL NOT BE USED FOR HIGH HEAT CONNECTIONS.
39. PORTIONS OF DUCTWORK THAT ARE VISIBLE THROUGH AIR DISTRIBUTION DEVICES LOCATED IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK.
40. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR THE CEILING SUPPORT STRUCTURE. DUCT SUPPORTS AND ATTACHMENTS TO THE
STRUCTURE SHALL BE PER SMACNA STANDARDS.
41. DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS.
42. EXCEPT FOR SUPPLY DUCTWORK BETWEEN AIR HANDLERS AND VAV TERMINAL UNITS, BALANCING DAMPERS SHALL BE INSTALLED WHERE THE BRANCH DUCT JOINS THE MAIN FOR ALL BRANCHES THAT
CONNECT TO SUPPLY, RETURN, AND EXHAUST OUTLETS AND INLETS WHETHER THE DAMPER IS SHOWN ON THE DRAWINGS OR NOT.
43. CONCENTRIC AND ECCENTRIC TRANSITIONS SHALL BE MADE UPSTREAM OF CONVERGING BRANCHES AND DOWNSTREAM OF DIVERGING BRANCHES. IN THE CONVERGING SITUATION THE DUCT AREA
SHALL INCREASE BEFORE THE BRANCH AIRFLOW JOINS THE MAIN FLOW AND IN THE DIVERGING SITUATION THE DUCT AREA SHALL DECREASE AFTER THE BRANCH AIRFLOW LEAVES THE MAIN AIRFLOW.
A MINIMUM OF SIX INCHES OF STRAIGHT DUCT SHALL BE BETWEEN THE BRANCH AND TRANSITION FITTINGS. THE MAXIMUM ANGLE FOR CONCENTRIC TRANSITIONS SHALL BE 45 DEGREES FOR
DIVERGING AND 60 DEGREES FOR CONVERGING AND THE MAXIMUM ANGLE FOR ECCENTRIC TRANSITIONS SHALL BE 30 DEGREES.
44. DUCTWORK OR PLENUMS INTO WHICH MOISTURE, OR PRECIPITATION, MAY ENTER OR ACCUMULATE, SUCH AS DUCTWORK CONNECTED TO LOUVERS, SHALL BE INSTALLED TO PRODUCE A MEANS OF
DRAINAGE. MEANS OF DRAINAGE MAY INCLUDE, BUT NOT BE LIMITED TO, SLOPING AND DRAINS.
45. OVERHEAD DUCTWORK SHALL BE INSTALLED TIGHT TO STRUCTURE WITH SPACE ALLOWED FOR INSULATION, UNLESS NOTED OTHERWISE.
46. IN ALL AREAS EXCEPT MECHANICAL ROOMS DUCTWORK THAT IS EXPOSED AND SHOWN AS ROUND OR FLAT OVAL SHALL BE DOUBLE WALL SPIRAL WITH INSULATION IN-BETWEEN THE WALLS IF THE
SERVICE REQUIRES THERMAL INSULATION.
47. WHERE DRAWINGS INDICATE THAT OPEN ENDS OF DUCTWORK ARE TO BE COVERED BY MESH, WIRE MESH, OR SCREEN, THE WIRE MESH SHALL BE 1/2-INCH BY 1/2-INCH ALUMINUM WITH WIRE THICKNESS
0.063-INCHES UNLESS OTHERWISE NOTED.
HVAC AIR DUCT LEAKAGE
48. LEAKAGE TEST PROCEDURES SHALL FOLLOW THE SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL. TESTS AND NECESSARY REPAIR OF DUCTWORK SHALL BE COMPLETED PRIOR TO CONCEALMENT OF
DUCTS. THE REQUIREMENTS FOR LEAK TESTING ARE DESCRIBED IN THE SPECIFICATIONS.
49. IF A TESTED SPECIMEN FAILS TO MEET SPECIFIED AIR LEAKAGE CRITERIA, THE CONTRACTOR SHALL MODIFY FABRICATION METHODS TO BRING CONSTRUCTION INTO COMPLIANCE AND SHALL RETEST
SPECIMEN UNTIL ACCEPTABLE DUCT AIR LEAKAGE IS DEMONSTRATED.
METAL AND FLEXIBLE DUCTWORK MATERIALS AND CONSTRUCTION
50. ALL JOINTS AND SEAMS IN ALL NON-WELDED SHEET METAL DUCTWORK SHALL BE SEALED WITH DUCT SEALER.
51. SIZE FLEXIBLE DUCT TO MATCH DEVICE NECK. INSTALL ADAPTORS, INCLUDING RECTANGULAR OR SQUARE TO ROUND ADAPTERS OR BOOTS, FOR CONNECTION OF ROUND FLEXIBLE DUCTS TO AIR
DEVICE NECKS WHEN REQUIRED. INSTALL ROUND GALVANIZED STEEL DUCT RUNOUTS TO ACHIEVE FLEXIBLE DUCT LENGTHS OF 5'_0" OR LESS.
52. FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIRFLOW RESTRICTIONS.
53. FLEXIBLE DUCTWORK SHALL NOT TO BE USED TO MAKE DIRECTIONAL CHANGES WHERE THE RADIUS OF CURVATURE IS REQUIRED TO BE LESS THAN TWO TIMES THE FLEXIBLE DUCT'S DIAMETER.
54. FLEXIBLE DUCTWORK SHALL BE INSTALLED WITH BAND HANGERS MINIMUM 1-INCH WIDE. MAXIMUM SAG SHALL NOT EXCEED ONE HALF-INCH PER FOOT OF LENGTH. MAXIMUM SUPPORT SPACING SHALL
BE 5-FEET.
55. FLEXIBLE DUCTWORK SHALL NOT BE INSTALLED THROUGH FIRE, SMOKE, OR FIRE AND SMOKE RATED PARTITIONS.
COOLING COIL CONDENSATE
56. CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED, SLOPED TO DRAIN, AND ROUTED TO DISCHARGE WHERE INDICATED, IF NO LOCATION IS INDICATED DISCHARGE AT THE
NEAREST FLOOR DRAIN UNLESS INDICATED OTHERWISE. WHERE INDICATED TO BE PUMPED CONDENSATE MAY BE PUMPED WITH CONTROLS INCLUDED AS REQUIRED BY CODE. DRAIN LINES SHALL BE
ROUTED TO AVOID INTERFERENCE WITH PASSAGEWAYS AND MAINTENANCE AND TO AVOID CREATING TRIPPING HAZARDS.
57. THE MINIMUM PIPE SIZE FOR CONDENSATE DRAIN LINES SHALL BE 3/4-INCHES DIAMETER.
58. ALL CONDENSATE PRODUCING AIR HANDLING UNITS, FAN COIL UNITS, AND EQUIPMENT LOCATED ABOVE THE FINISHED CEILING OF THE LOWEST LEVEL SHALL BE INSTALLED WITH A CODE COMPLIANT
CONDENSATE DRAINAGE SYSTEM. THE SYSTEM MAY CONSIST OF ONE OF THE FOLLOWING: (A) A CODE COMPLIANT AUXILIARY DRAIN PAN LOCATED UNDER THE COILS EQUIPPED WITH A UL508 WATER
LEVEL SWITCH LOCATED IN THE PAN THAT DE-ACTIVATES THE UNIT UPON DETECTION OF WATER PRIOR TO OVERFLOW OF THE PAN; OR IF ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION THE
FOLLOWING MAY BE USED IN LIEU OF THE AUXILIARY PAN, (B) A CODE COMPLIANT DEVICE AND INSTALLATION INCLUDING AN ELECTRONIC WATER DETECTOR WIRED TO SHUTDOWN THE UNIT IN THE
EVENT THAT THE PRIMARY DRAIN LINE IS BLOCKED.
MECHANICAL NOTES MECHANICAL NOTES - CONTINUED
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
M-701
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
S C
H E
D U
LE
S
DAC
12827127
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A L L A N
CA
R R
034339
SEAL
E NG I N E E R
clacross
MECHANICAL NOTES - CONTINUED
ROOFTOP EQUIPMENT AND LOUVERS
59. ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED LEVEL. CONTRACTOR SHALL COORDINATE ROOF SLOPE WITH ARCHITECTURAL DRAWINGS.
60. UNLESS NOTED OTHERWISE, ROOF CURBS SHALL BE CUSTOM CURB OR APPROVED EQUAL. ROOF CURBS SUPPLIED AS STANDARD BY THE MANUFACTURER OF THE MECHANICAL EQUIPMENT BEING
INSTALLED ON THE CURB ARE ACCEPTABLE. SUBMIT ROOF CURB INFORMATION WITH PRODUCT DATA AND SHOP DRAWINGS. VIBRATION/SOUND ATTENUATING ROOF CURBS, WHERE SCHEDULED OR
NOTED, SHALL BE MASON RSC-A (2-1/2-INCHES) OR EQUAL WITH ACOUSTICAL PACKAGE.
61. ROOFTOP HVAC UNITS SHALL BE INSTALLED SUCH THAT THE ROOF DECK IS COMPLETE AND CONTINUOUS UNDER THE BOTTOM OF THE HVAC UNITS, AND SO THAT THE ROOF DECK IS CUT ONLY FOR THE
UNIT SUPPLY AND RETURN OPENINGS. THE SPACE INSIDE OF ROOF CURBS BETWEEN THE ROOF DECK AND THE BOTTOM OF THE ROOFTOP HVAC UNITS SHALL BE FILLED WITH HIGH-DENSITY
ACOUSTICAL INSULATION.
62. UNLESS NOTED OTHERWISE, BLANK OFF UN-USED PORTIONS OF LOUVERS. INSTALL BLANK OFF PANEL ON ROOM SIDE OF LOUVER. BLANK OFF PANEL SHALL BE CONSTRUCTED OF GLASS FIBER
INSULATION SANDWICHED BETWEEN TWO SHEETS OF 22-GAUGE GALVANIZED SHEET METAL. THE INSULATION SHALL BE COMPLETELY ENCLOSED AND THE ENCLOSURE SEALED. THE INSULATION SHALL
BE 6 LB. PER CU. FT. DENSITY MINIMUM 2-INCHES THICK. THE INSULATION SHALL BE SECURED IN PLACE WITH MECHANICAL FASTENERS 6-INCHES ON CENTER.
REFRIGERANT PIPING FOR HVAC EQUIPMENT, HYDRONIC PIPING, AND FLUES
63. WHEN THE ACCUMULATED EQUIVALENT LENGTH OF REFRIGERANT LINES BETWEEN PIECES OF EQUIPMENT EXCEEDS THE MANUFACTURER'S RECOMMENDED LENGTHS FOR LINES WITH STANDARD
DIAMETER SIZES THEN FURNISH AND INSTALL A MANUFACTURER'S APPROVED REFRIGERANT PIPING DIAGRAM FOR TYPICAL SYSTEMS SHOWING RECOMMENDED PIPE SIZES AND COMPONENTS SUCH AS
SUCTION LINE ACCUMULATORS WHEN REQUIRED AND INSTALL REFRIGERANT PIPING AS RECOMMENDED BY THE MANUFACTURER.
64. REFRIGERANT PIPING MUST BE VACUUM TESTED TO 300 MICRONS FOR 24 HOURS AFTER THE HIGH PRESSURE TEST. THE SYSTEM FAILS THE TEST IF WITH THE VACUUM PUMP DISCONNECTED FROM
THE SYSTEM, THE PRESSURE RISES ABOVE 300 MICRONS AFTER 24 HOURS.
65. SLOPE ALL HORIZONTAL GAS FLUE PIPING MINIMUM 1/4-INCHES PER FOOT. INSTALL PER BOILER OR WATER HEATERS INSTALLATION INSTRUCTIONS.
66. INSTALL MANUAL AIR VENTS AT HIGH POINTS OF ALL CIRCULATING WATER PIPING SYSTEMS. INSTALL WITH SUFFICIENT SLOPE TO YIELD AIR VENTING.
67. INSTALL DRAIN TEES WITH MANUAL FULL-PORT BALL VALVES AT LOW POINTS OF ALL CIRCULATING WATER AND GLYCOL PIPING SYSTEMS. INSTALL WITH SUFFICIENT SLOPE TO YIELD DRAINING.
68. PIPING AT PUMPS AND EQUIPMENT SHALL BE SUPPORTED SO THAT NO PIPING OR ACCESSORY LOAD IS CARRIED BY THE PUMP, EQUIPMENT, OR FLEX CONNECTORS.
69. FOR ALL HYDRONIC PIPING, THE MINIMUM PIPE SIZE SHALL BE 3/4-INCHES DIAMETER, LONG RADIUS ELBOWS SHALL BE USED, AND UNLESS INDICATED OTHERWISE, PIPING SHALL BE INSTALLED BENEATH
DUCTWORK.
70. GROOVED COUPLINGS IN PIPING SYSTEMS ARE NOT PERMITTED.
71. EXTRUDED TEES IN COPPER PIPING ARE ACCEPTABLE FOR MAINS 2-INCH AND LARGER WITH THE BRANCH 1/2-INCH OR LESS THAN THE MAIN. JOINT MUST BE BRAZED.
72. PRESS TYPE FITTINGS FOR COPPER ARE NOT PERMITTED.
73. PIPING SHALL BE INSTALLED SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND OTHER APPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.
74. VALVES AND SPECIALTIES SHALL BE LINE SIZE UNLESS INDICATED OTHERWISE. VALVES SHALL BE INSTALLED IN LOCATIONS SO THAT THE VALVES REMAIN IN SERVICE WHEN THE EQUIPMENT OR PIPING
IS REMOVED.
75. VALVES SHALL HAVE POSITION INDICATORS. BALANCING VALVES SHALL HAVE ADJUSTABLE MEMORY STOPS.
76. BUTTERFLY AND BALL VALVES ARE PERMITTED. GATE VALVES SHOULD NOT BE USED.
77. AT EQUIPMENT CONNECTIONS LOCATE PIPING TRANSITIONS BETWEEN EQUIPMENT AND VALVES AND STRAINERS.
78. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR THE CEILING SUPPORT STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE
HUNG FROM THE TOP CHORDS OF THE JOISTS.
79. ISOLATION VALVES SHALL BE INCLUDED AND INSTALLED IN ALL PIPES CONNECTED TO EACH PIECE OF EQUIPMENT AND PIPING ACCESSORY FOR WHICH MAINTENANCE OR REPLACEMENT OF THE
EQUIPMENT OR ACCESSORY WOULD REQUIRE SYSTEM SHUT-DOWN.
ATFP DAMPERS
80. ATFP DAMPERS SHALL BE AMCA CLASS 1A LOW LEAKAGE (3 CFM PER SQUARE FOOT FACE AREA AT 1-INCH W.C. PER AMCA 511). ATFP DAMPERS SHALL BE INSTALLED WHERE INDICATED IN ALL BUILDING
ENVELOPE PENETRATIONS BETWEEN OCCUPIED AREAS AND OUTDOORS THAT SERVE FOR RELIEF, EXHAUST, AND OUTDOOR AIR. DAMPERS SHALL BE CONTROLLED TO CLOSE UPON SIGNAL FROM THE
ATFP SWITCH AN OPENUPON MANUAL RESET OF THE SWITCH. ACTUATORS SHALL BE 24V ac WITH SPRING RETURN AND CONTROL SYSTEM POSITION FEEDBACK.
VIRGINIA BEACH, VA 23462
SUITE 1400
757·455·5800 FAX 757·455·5638
WWW.CLARKNEXSEN.COM
4525 MAIN STREET
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
N
A V
A L
S T
A T
IO
N
N
O R
F O
L K
V
A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
XXXXX-XX-X-XXXX
1572053
M-702
P S
O F
M O
T O
R T
R A
N S
P O
R T
M A
IN
T
E N
A N
C E
E X
P A
N S
IO
N
S
IT
E
S C
H E
D U
LE
S
DAC
12827128
JRS JDD
12/2/2020
APPROVED BY SOFIA SCHWARTZ, DEPUTY DIRECTOR
OF INSTALLATION DEVELOPMENT, WITH MCB CAMP
LEJEUNE, VIA EMAIL
SGL/JPC
JA
C
K S
O N
V
IL
LE
, N
C M
C B
C A
M P
L E
JE
U
N E
EJA
ALG
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N O
R T H
C A R O L I N
A
P R
OF E S S I ONA
L
D W
A Y N E A…